36_10_TSP4.0-PII_Plumbing_Plan_-_DWV_Phase_2.pdf

PDF 468 KB Posted

Attached to
Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
Solicitation number
W9127S19Q6039
Issued by
Department of the Army Corps of Engineers Engineering District Little Rock

About this file

Part of Attachment I - As-Builts, 36-TPF South Ambulance

View the file

Other files for this federal contract opportunity

Other files attached to Tyndall AFB Temporary Modular Medical Facility, newest first.
File Type Posted
1-V1.04_SURVEY_PLAN.pdf PDF
49_25__TPFV4.0_STANDARD_RAMP_AND_STAIR_DETAILS_STAMPED.pdf PDF
55_TQ3.11C_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_C.pdf PDF
55_TQ3.11_-_FFE_PLAN_-_TPF_PHASE_1.pdf PDF
55_TQ4.11C_-_FFE_PLAN_-_TPF_PHASE_2,_AREA_C.pdf PDF
49_24__TPF3.0_Full_Luminary_Plan.pdf PDF
49_23__TCP1.2_Combined_Clinic_TPF_RCP.pdf PDF
49_23__TCP1.0_Combined_Clinic_TPF_RCP.pdf PDF
55_TQ3.11B_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_B.pdf PDF
49_24__TPF7.0_Overall_Plumbing_Plan_-_D.W.V.pdf PDF
49_25__TPFV3.0_STANDARD_RAMP_AND_STAIR_DETAILS_STAMPED.pdf PDF
49_25__TPFV5.0_STANDARD_CANOPY_DETAILS_STAMPED.pdf PDF
49_24__TPF2.1-P2_Full_Building_Plan_Phase_2.pdf PDF
1-V1.07_SURVEY_PLAN.pdf PDF
1-V1.02_SURVEY_PLAN.pdf PDF
49_24__TPF2.0_Full_Building_Plan.pdf PDF
49_23__TCP1.4-PII_Combined_Clinic_TPF_RCP-PHASE_II.PDF PDF
1-V1.06_SURVEY_PLAN.pdf PDF
49_24__TPF6.0_Overall_Plumbing_Plan_-_Supply.pdf PDF
49_21__TFP3.1_Combined_Clinic_TPF_Fire_Suppression_Plan_Phase_1.pdf PDF
29_06_TNX1.0_Building_Cross_Section.pdf PDF
43_16_TCCA1.0_Exterior_Elevations.pdf PDF
36_10_TSP3.0-PII_Plumbing_Plan_-_Supply_Phase_2.pdf PDF
07_E0-02_-_SYMBOL_LEGEND_AND_GENERAL_NOTES.pdf PDF
36_09_TSA2.0_Floor_Plan.pdf PDF
36_11_TSE3.0_Task_Lighting_Illumination_Plan.pdf PDF
29_02_TNA4.0_Egress_Plan.pdf PDF
36_09_TSA3.0_Reflective_Ceiling_Plan.pdf PDF
29_03_TNP2.0_Plumbing_Schematics.pdf PDF
43_16_TCCA4.0_Egress_Plan.pdf PDF
43_17_TCCE1.0_Elec_Plan.pdf PDF
29_04_TNE3.0_Task_Lighting_Illumination_Plan.pdf PDF
29_05_TNM1.0_Mechanical_HVAC_Plan.pdf PDF
36_10_TSP1.0_Plumbing_Schematics.pdf PDF
36_09_TSA1.0_Exterior_Elevations.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Response_to_Questions_19Aug19.pdf PDF
29_04_TNE4.0_MDP_-_One_Line_Diagram.pdf PDF
05_1-CU1.02_UTILITY_PLAN_-_PHASE_2_AND_3.pdf PDF
29_03_TNP3.0_Plumbing_Plan.pdf PDF
36_12_TSM1.0_Mechanical_HVAC_Plan.pdf PDF
29_03_TNP4.0_Plumbing_Plan_-_DWV.pdf PDF
29_01_TNC1.0_Cover_Sheet-Notes.pdf PDF
29_03_TNP1.0_Plumbing_Schematics.pdf PDF
43_19_TCCX2.0_Roof_Drain_Details.pdf PDF
43_19_TCCX1.0_Building_Cross_Section.pdf PDF
29_07_TNFD1.0_Foundation_Plan_and_Details.pdf PDF
Attachment_C_-_AFMSA_Design_Guidance.pdf PDF
Attachment_B_-_Utility_Plans.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Combined_Synopsis_Solicitation.pdf PDF
Attachment_G_-_PFD_TYNDALL_TPF_v2_20190702.pdf PDF
Show all 50

Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE: 3/16"=1'-0"

PLUMBING PLAN - D.W.V. - PHASE 1

A

54321

B

C

D

E

B A

S E

C

IV

IL

E

N G

IN

E

E R

/D E

P U

T Y

C H

IE

F

E N

G

IN

E E

R

IN

G F

L

IG

H T

C

E P

C H

IE

F

C O

N T

R A

C T

S S

E C

T

IO

N

C E

P M

R E

C O

M M

E N

D E

D

R E

C O

M M

E N

D E

D

A P

P R

O V

E D

R E

V D

A T

E E

N G

IN

E

E R

\D E

S

IG

N E

R

D R

A W

N B

Y

S C

A L

E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

C O

N T

R A

C T

N U

M B

E R

D E

S

IG

N T

E A

M C

E P

M

U S

IN

G

A G

E N

C Y

C H

E C

K E

D B

Y

H O

E F

E R

W Y

S O

C K

I A

R C

H

IT

E C

T S

/3

/2

JE DUNN + HWA

CLEARWATER, FL 33756

CONSULTING ENGINEER

1765 CARNEGIE AVENUE

Ph: (727) 505-9941

JAMES E. BRADLEY, P.E.

J E B

0' 4' 8' 16' 32'

1/8" = 1'-0"

0' 2' 4' 8' 16'

1/4" = 1'-0"

0' 1' 2'

3/4" = 1'-0"

4'0' 1'

1 1/2" = 1'-0"

2' 2'1'6"6"3"0' 6"

3" = 1'-0"

1'3"

2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930

TPF TYNDALL - SOUTH

AMBULANCE SERVICES BLDG

A S

I N

D

IC

A T

E D

J A

M E

S E

B

R A

D L

E Y

P

.E

W

-1

-R -6

W

-1

-D -6

J .L

.B

J E

D U

N N

J .E

.B

S U

B M

IT

T

A L

C O

R R

E C

T E

D F

IN

A

L

& ASSOCIATES

HILBORN, WERNER, CARTER

1627 SOUTH MYRTLE AVE.

CLEARWATER, FLORIDA 33756

THIRD PARTY:

P L

U M

B

IN

G P

L A

N

D .W

.V

P H

A S

E

T Y

N D

A L

L A

F B

A M

B U

L A

N C

E S

E R

V

IC

E S

B L

D G

TS

4.0 PII

M

A G

N O

L

IA

C

IR

C L

E T

Y N

D A

L L

A F

B

F L

S y m b o l D es cr ip ti o n

T ra ck in g N o

A ct io n

D at e

DN

A B C D E F G H i J K L M N o P

STORAGE

STAFF

LOUNGE/TEAM

CONFERENCE

ROOM

NCO

OFFICE

(SHARED)

WORKSTATION

WORKSTATION

STORAGE

SHELVING

OFFICE

COMMANDER

ADMIN

OFFICE

MED

RECORDS

WORKSTATION

CONSULT

OFFICE

PERSONAL

PROPERTY

LOCKERS

EXERCISE

AREA

PATIENT

TOILET

STAFF

TOILET JANITOR'S

CLOSET

30 GAL

W/H

STAFF

LOUNGE /

CONFERENCE

ROOM

NCOIC

OFFICE

WAITING

RECEPTION

COPY/FILE

DISTRO

OFFICE

EXAM

ROOM

COMM

ROOM

OFFICE

EXAM

ROOM

APPOINTMENT

CLEARKS

SHIPPING/

RECEIVING

TECHNICAL

SUPERVISOR

SHARED

NCOIC

OFFICE

OIC

OFFICE

CENTRAL

STORAGE

M/TLT

MICRO

BIOLOGY

JANITOR

30 GAL

W/H

F/TLT

SPECIMEN

TOILET

WAITING

RECEPTION

COPY/FILE

DISTRO

TECH

TECH

BLOOD

DRAW AREA

CORE

LAB

STAFF

LOUNGE/TEAM

CONFERENCE

ROOM

SIMULATION

CLASSROOM

CHIEF

ED&T

OFFICE

MDG

COMPUTER

CLASSROOM

MAIN

CLASSROOM

EXERCISE

AREA

B-102

B-104

B-101

S-106

S-105

S-103

S-101d

S-101a

S-104

S-102 G-109aG-109b

A-107

G-108

A-106 G-107 G-106

G-102

G-101

G-103

G-103

A-101

A-102

G-105

G-104

A-105

A-104

A-103

K-107

K-103

K-104

K-104a

K-101

K-102

K-108 K-109

K-111 K-112

P-106

K-105a

K-105

P-101

A-108

P-102

P-103

I/D UNIT

O/D UNIT

STAFF

TOILET

B-103

ON-CALL

ROOM

B-105

KITCHEN

B-104a

S-101c

S-101b

G-102a

K-105b

STAFF

TOILET

JANITOR

A-106 K-106

STORAGE

P-105

TECH

OFFICE

A-646

CRUTCH

SPLINT/STO

G-107

OIC

OFFICE

PATIENT

TOILET

DN

DN

30 GAL

W/H

ON-CALL

ROOM

B-106

DN

S

IN

K

SINK S

IN

K

2"VTR

3"C.O.

2"B.V.

3"VTR

D R

A

IN

D R

A

IN

3" DRAIN3" DRAIN

4"C.O.

D R

A

IN

3" DRAIN

/2

D R

A

IN

1 1/2"A.V.

1 1/2"A.V.1 1/2"A.V.

1 1/2"A.V.

1 1/2"VTR

4" DRAIN4" DRAIN4" DRAIN4" DRAIN

3"VTR

2"B.V.

2"B.V.

2"VTR

2"B.V.

2"B.V.

2"B.V.

3"VTR

1 1/2"VTR

3"VTR3"VTR

4"C.O.

2"VTR 3"VTR

1 1/2"A.V.1 1/2"A.V.

3"VTR

2"VTR

4" DRAIN4" DRAIN4" DRAIN4" DRAIN4" DRAIN

D R

A

IN

/2

D R

A

IN

/2

D R

A

IN

1 1/2" DRAIN

D R

A

IN

D R

A

IN

/2

D R

A

IN

/2

D R

A

IN

D R

A

IN

D R

A

IN

D R

A

IN

D R

A

IN

D R

A

IN

January 27, 2017

VALID

tracbr Text Box Amendment 1 tracbr Rectangle tracbr Text Box 3/15/2017 tim.kitchens Snapshot

File details come from the government source that posted it.