36_11_TSE1.0_Electrical_Plan.pdf

PDF 601 KB Posted

Attached to
Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
Solicitation number
W9127S19Q6039
Issued by
Department of the Army Corps of Engineers Engineering District Little Rock

About this file

Part of Attachment I - As-Builts, 36-TPF South Ambulance

View the file

Other files for this federal contract opportunity

Other files attached to Tyndall AFB Temporary Modular Medical Facility, newest first.
File Type Posted
49_22__TLV2.0_Combined_Clinic_TPF_Low_Voltage_Systems_Notes_&_Details.pdf PDF
1-V1.07_SURVEY_PLAN.pdf PDF
1-V1.02_SURVEY_PLAN.pdf PDF
49_24__TPF2.0_Full_Building_Plan.pdf PDF
49_23__TCP1.4-PII_Combined_Clinic_TPF_RCP-PHASE_II.PDF PDF
1-V1.06_SURVEY_PLAN.pdf PDF
49_24__TPF6.0_Overall_Plumbing_Plan_-_Supply.pdf PDF
49_21__TFP3.1_Combined_Clinic_TPF_Fire_Suppression_Plan_Phase_1.pdf PDF
49_23__TCP1.1_Combined_Clinic_TPF_RCP.pdf PDF
49_25__TPFV1.0_COVER_SHEET_STAMPED.pdf PDF
49_25__TPFV8.0_CANOPY_ASSEMBLY_AND_FOOTING_DETAILS_STAMPED.pdf PDF
55_TQ3.11D_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_D.pdf PDF
55_TQ4.11_-_FFE_PLAN_-_TPF_PHASE_2.pdf PDF
49_21__TFP1.0_Combined_Clinic_TPF_Life_Safety_Narrative.pdf PDF
1-V1.04_SURVEY_PLAN.pdf PDF
49_25__TPFV4.0_STANDARD_RAMP_AND_STAIR_DETAILS_STAMPED.pdf PDF
55_TQ3.11C_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_C.pdf PDF
55_TQ3.11_-_FFE_PLAN_-_TPF_PHASE_1.pdf PDF
55_TQ4.11C_-_FFE_PLAN_-_TPF_PHASE_2,_AREA_C.pdf PDF
49_24__TPF3.0_Full_Luminary_Plan.pdf PDF
36_12_TSM1.0_Mechanical_HVAC_Plan.pdf PDF
29_03_TNP4.0_Plumbing_Plan_-_DWV.pdf PDF
29_01_TNC1.0_Cover_Sheet-Notes.pdf PDF
29_03_TNP1.0_Plumbing_Schematics.pdf PDF
43_19_TCCX2.0_Roof_Drain_Details.pdf PDF
43_19_TCCX1.0_Building_Cross_Section.pdf PDF
29_07_TNFD1.0_Foundation_Plan_and_Details.pdf PDF
36_11_TSE1.1_Electrical_Panel_Schedules.pdf PDF
36_10_TSP3.0_Plumbing_Plan_-_Supply_Phase_1.pdf PDF
05_1-CU1.01_UTILITY_PLAN_-_PHASE_1.pdf PDF
43_20_TCCFD1.0_Foundation_Plan_and_Details.pdf PDF
36_09_TSA4.0-PII_Egress_Plan.pdf PDF
07_ES1-01_-_ELECTRICAL_SITE_PLAN_-_MEDICAL_CLINIC_BUILDING_1465.pdf PDF
36_11_TSE3.0-PII_Task_Lighting_Illumination_Plan_Phase_2.pdf PDF
29_06_TNX1.0_Building_Cross_Section.pdf PDF
43_16_TCCA1.0_Exterior_Elevations.pdf PDF
36_10_TSP3.0-PII_Plumbing_Plan_-_Supply_Phase_2.pdf PDF
07_E0-02_-_SYMBOL_LEGEND_AND_GENERAL_NOTES.pdf PDF
36_09_TSA2.0_Floor_Plan.pdf PDF
36_11_TSE3.0_Task_Lighting_Illumination_Plan.pdf PDF
29_02_TNA4.0_Egress_Plan.pdf PDF
36_09_TSA3.0_Reflective_Ceiling_Plan.pdf PDF
29_03_TNP2.0_Plumbing_Schematics.pdf PDF
43_16_TCCA4.0_Egress_Plan.pdf PDF
43_17_TCCE1.0_Elec_Plan.pdf PDF
29_04_TNE3.0_Task_Lighting_Illumination_Plan.pdf PDF
29_05_TNM1.0_Mechanical_HVAC_Plan.pdf PDF
Attachment_C_-_AFMSA_Design_Guidance.pdf PDF
Attachment_B_-_Utility_Plans.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Combined_Synopsis_Solicitation.pdf PDF
Show all 50

Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INCANDESCENT SP

FIXTURE (60w MAX)

WEATHERPROOF LIGHT

"PORCH" (W. PER SPEC)

HVAC DISCONNECT

(4x4 DOUBLE GANG)

PROGRAMMABLE A/C THERMOSTAT @ 53" A.F.F.

(80" BOX: 4x4 DOUBLE GANG)

ILLUMINATED EXIT SIGN AND EMERGENCY

LIGHTING COMBO w/BATTERY BACK-UP

J-BOX @ 80" A.F.F. FOR STROBE ONLY

EXHAUST FAN-100 CFM (UNLESS NOTED)

HORN/STROBE (48" BOX: 2x4 SINGLE GANG)

WIRED BACK TO HORN/STROBE (2x4 SINGLE GANG)

J-BOXES @ 48" & 80" A.F.F. FOR PULL STATION AND

EXHAUST FAN & LIGHT COMBO-100 CFM (UNLESS NOTED)

J-BOX @ 48" A.F.F. FOR PULL STATION - TO BE

J CEILING MOUNTED JUNCTION BOX

FLOOR MOUNTED JUNCTION BOXJ D

3-WAY SWITCH @ 48" A.F.F.

TELEPHONE JACK AT

42" A.F.F. (UNLESS NOTED)

DUPLEX RECEPTACLE @ 42" A.F.F. (UNLESS NOTED)

ELECTRICAL SYMBOLS

DUPLEX RECEPTACLE @ 16" A.F.F.

ELECTRICAL PANEL BOX 48" TO BOTTOM

WALL MOUNTED JUNCTION BOX 16" (UNLESS NOTED)

COMPUTER JACK @ 16" A.F.F. (UNLESS NOTED)

RECPTACLE 240v @ 16" A.F.F.

QUADPLEX RECEPTACLE @ 16" A.F.F. (UNLESS NOTED)

RECEPTACLE

DUPLEX RECEPTACLE

SWITCH @ 48" A.F.F.

CEILING MOUNTED

FLOOR DUPLEX

TELEPHONE JACK AT

16" A.F.F. (UNLESS NOTED)

TELEPHONE FLOOR J-BOX

S

J

C

3S

CEILING MOUNTED

FLOOR QUADPLEX

RECEPTACLE

QUADPLEX RECEPTACLE

H

S

EXIT B

W.P.

T

P

"FLOOD" (W. PER SPEC)

RECESSED INCANDESCENT

WEATHERPROOF LIGHT

LIGHT FIXTURE (40w MAX)

W.P.

(2 TUBE = 72w MAX.)

1'x4' FLUORESCENT - DIFFUSED - SURFACE MOUNTED

SCALE: 3/16"=1'-0"

ELEC PLAN

A

54321

B

C

D

E

B A

S E

C

IV

IL

E

N G

IN

E

E R

/D E

P U

T Y

C H

IE

F

E N

G

IN

E E

R

IN

G F

L

IG

H T

C

E P

C H

IE

F

C O

N T

R A

C T

S S

E C

T

IO

N

C E

P M

R E

C O

M M

E N

D E

D

R E

C O

M M

E N

D E

D

A P

P R

O V

E D

R E

V D

A T

E E

N G

IN

E

E R

\D E

S

IG

N E

R

D R

A W

N B

Y

S C

A L

E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

C O

N T

R A

C T

N U

M B

E R

D E

S

IG

N T

E A

M C

E P

M

U S

IN

G

A G

E N

C Y

C H

E C

K E

D B

Y

H O

E F

E R

W Y

S O

C K

I A

R C

H

IT

E C

T S

/3

/2

JE DUNN + HWA

CLEARWATER, FL 33756

CONSULTING ENGINEER

1765 CARNEGIE AVENUE

Ph: (727) 505-9941

JAMES E. BRADLEY, P.E.

J E B

0' 4' 8' 16' 32'

1/8" = 1'-0"

0' 2' 4' 8' 16'

1/4" = 1'-0"

0' 1' 2'

3/4" = 1'-0"

4'0' 1'

1 1/2" = 1'-0"

2' 2'1'6"6"3"0' 6"

3" = 1'-0"

1'3"

2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930

TPF TYNDALL - SOUTH

AMBULANCE SERVICES BLDG

A S

I N

D

IC

A T

E D

J A

M E

S E

B

R A

D L

E Y

P

.E

W

-1

-R -6

W

-1

-D -6

J .L

.B

J E

D U

N N

J .E

.B

S U

B M

IT

T

A L

C O

R R

E C

T E

D F

IN

A

L

& ASSOCIATES

HILBORN, WERNER, CARTER

1627 SOUTH MYRTLE AVE.

CLEARWATER, FLORIDA 33756

THIRD PARTY:

E L

E C

T R

IC

A

L P

L A

N

T Y

N D

A L

L A

F B

A M

B U

L A

N C

E S

E R

V

IC

E S

B L

D G

TSE1.0

M

A G

N O

L

IA

C

IR

C L

E T

Y N

D A

L L

A F

B

F L

S y m b o l D es cr ip ti o n

T ra ck in g N o

A ct io n

D at e

T-GRID SYMBOLS

DUCT WITH FLEX DUCT DROP

TO CEILING REGISTERS (RETURN)

(UNLESS NOTED OTHERWISE)

8" FLEX DUCT - RETURN

(UNLESS NOTED OTHERWISE)

8" FLEX DUCT - SUPPLY

TO CEILING REGISTERS (SUPPLY)

OVERHEAD FIBERGLASS RIGID

DUCT WITH FLEX DUCT DROP

OVERHEAD FIBERGLASS RIGID

2'x2' SUPPLY AIR REGISTER

TROFFER PER SPECS.

2'x2' RETURN AIR REGISTER

2'x4' FLOURESCENT (2 TUBE 32w BULBS - 64w MAX)

EXHAUST FAN-100 CFM (UNLESS NOTED)

(NOTE: MANUAL VOLUME CONTROL DAMPERS

TO BE LOCATED AT EACH TAKE OFF)

(NOTE: MANUAL VOLUME CONTROL DAMPERS

TO BE LOCATED AT EACH TAKE OFF)

SWITCH w/OCCUPANCY SENSOR @ 48" A.F.F.

S

O S

H-2 H-2

H-2 H-2

G-2

G -2

G-2

G -2

H-2

H-2

H-2

H-2

H-2

H-2

H-2

H-2

H-2 i-2i-2 i-2

L-2

L-2

N-2

J-2

K-2

K-2

K-2

K-2

K-2

K-2

K-2 N-2

K-2 i-2 i-2 i-2

J-2

J-2

J-2 i-i-6 i-6 i-2

K-2

K-2

K-2

K-2

L-2L-2L-2 L-2 L-2

M-2

L-2 L-2

L-2 L-2

K-2 o-2

N-2

N-2

P-2P-2

P-2

P-2

M-2P o-2 o-2 o-2 o-2 o-2 o-2 o-2

P-2 o-2

P-2 o-2 o-2 o-2 o-2 o-2

J-2

A-2

W.P. W.R.

GFI @ 24"

A.F.F.

GFI

G

FI

REFRG

A-2

B-2

PG

FI

S O S

A-4 W.P. W.R.

GFI @ 24"

A.F.F.

C-4 W.P. W.R.

GFI @ 24"

A.F.F.

E-4 W.P. W.R.

GFI @ 24"

A.F.F.

G-4 W.P. W.R.

GFI @ 24"

A.F.F.

i-4 W.P. W.R.

GFI @ 24"

A.F.F.

K-4 M-4 W.P. W.R.

GFI @ 24"

A.F.F.

o-4 W.P. W.R.

GFI @ 24"

A.F.F.

A-4

A-4

A-4

A-5

A-5

A-5

A-6

P H

P H P H

H

B-4

B-4

B-5

B-5

B-4

B-6

S

S

C-2

C-2

C-2

C-2

J C-4 D-4

D-4

C-4

C-4

C-4

C-6

D-2

D-4

D-4GFI

G

FI

D-5

D-5

D-5

D-5

S O S

30 GAL WATER HEATER;

240v, 1Ø; 30A(2P);

4.5 kW MAX.

D D-6/8

HEAT TAPE RECEPT

MOUNTED UNDER

FLOOR

W.P.

W.R.

GFI

D-5

E-4

F-4

G-4

E-8

DED

E-7

E-6

E-6

S O S

E-7

F-4

F-4

S O S

E-6 F-4

S O S

G-6

G-6

H-5

G-6

G-6

G-6

H-5

H-4

G-5 G-5

G-5

H-4

3/4" x 48"x96" PLYWOOD

PAINTED WITH FIRE

RESISTANT PAINT, TYP.

D E

D D

E D

G-8

WALL MOUNTED MINI-SPLIT

A/C UNIT; (COOLING ONLY)

FREDRICH (350 CFM); BOTTOM

OF UNIT TO BE AT 80" A.F.F.

OUTDOOR CONDENSING UNT; FREDRICH

#MR12CH; OUTSIDE CONDENSING UNIT

(12,300 BTUH COOLING ONLY); ALL

CONDENSATE LINES AND WIRING TO

INDOOR UNITS ARE TO BE SITE

INSTALLED BY SMM; UNIT IS SHIPPED

LOOSE AND SITE INSTALLED

D G-7

G-5

H-5

G-9

H-2

H-2

H-2

H-2

H-2

PH

H-2

H-2

H-4

H-4

H-5

H-5 i-4 i-4 J-10 i-4 i-5

K-4

K-5 i-5 i-5

J-5

J-5

J-4

J-4

K-5

J-6 J

K-5 i-5 i-5

J-5 K-5

J-6

J-6G

FI

N-2

N-2

N-2

N-2

N-2

K-2

K-4 K-4 L-4

L-4

L-4

L-5

K-5

K-2

K-2

L-4 M-5

N-5

N-8

L-5 L-5

M-4

L-5

A-1/3 B-1/3 C-1/3 D-1/3 E-1/3 F-1/3 G-1/3 H-1/3 i-1/3 J-1/3 K-1/3 L-1/3 M-1/3 N-1/3 o-1/3 P-1/3

3.0 TON WALL HUNG HVAC UNIT

(MD#: WA372-A10RX4XX) INSTALLED

PER MFG'R SPEC'S w/10 kW HEAT

STRIP; 1200 CFM @ .3 IWC ESP w/25% FRESH AIR INTAKE; TYP. of (16)

3.0 TON WALL HUNG HVAC UNIT

(MD#: WA372-A10RX4XX) INSTALLED

PER MFG'R SPEC'S w/10 kW HEAT

STRIP; 1200 CFM @ .3 IWC ESP w/25% FRESH AIR INTAKE; TYP. of (16)

3.0 TON WALL HUNG HVAC UNIT

(MD#: WA372-A10RX4XX) INSTALLED

PER MFG'R SPEC'S w/10 kW HEAT

STRIP; 1200 CFM @ .3 IWC ESP w/25% FRESH AIR INTAKE; TYP. of (16)

3.0 TON WALL HUNG HVAC UNIT

(MD#: WA372-A10RX4XX) INSTALLED

PER MFG'R SPEC'S w/10 kW HEAT

STRIP; 1200 CFM @ .3 IWC ESP w/25% FRESH AIR INTAKE; TYP. of (16)

N-4

GFI

N-6

M-6

N-4 o-4 P-4

P-4

P-5 o-4

P-5

N-4

N-5 o-4 o-5

N-6

P-6 o-5 o-5 o-2

L-2 o-2 o-2 o-2

P-5

P-5

P-6

P-5

P-6

P-6

P-7

P-7

P-6

P-6

T T

T

T T

T

T

T T

T

T T T

T T

T

30 GAL WATER HEATER;

240v, 1Ø; 30A(2P);

4.5 kW MAX.D i-7/9

HEAT TAPE RECEPT

MOUNTED UNDER

FLOOR

i-5 W.P.

W.R.

GFI

M-2 o-2

N-2

A-6

S O S

C-5

A-6 A-2

C -7

B-5

M-2 M-6 o-2

M-6

N-5

GFI

GFI

i-4 i-5 i-2 i-6

NOTE:

CEILING HEIGHT IN "EXCERCISE

AREA" TO BE MINIMUM OF

9'-0"; MODULES "E" & "F" AND

ONLY

NOTE:

CEILING HEIGHT IN "EXCERCISE

AREA" TO BE MINIMUM OF

9'-0"; MODULES "E" & "F" AND

ONLY

D

A B C D E F G H i J K L M N o P

STORAGE

STAFF

LOUNGE/TEAM

CONFERENCE

ROOM

NCO

OFFICE

(SHARED)

WORKSTATION

WORKSTATION

STORAGE

SHELVING

OFFICE

COMMANDER

ADMIN

OFFICE

MED

RECORDS

WORKSTATION

CONSULT

OFFICE

PERSONAL

PROPERTY

LOCKERS

EXERCISE

AREA

PATIENT

TOILET

STAFF

TOILET JANITOR'S

CLOSET

30 GAL

W/H

STAFF

LOUNGE /

CONFERENCE

ROOM

NCOIC

OFFICE

WAITING

RECEPTION

COPY/FILE

DISTRO

OFFICE

EXAM

ROOM

COMM

ROOM

OFFICE

EXAM

ROOM

APPOINTMENT

CLEARKS

SHIPPING/

RECEIVING

TECHNICAL

SUPERVISOR

SHARED

NCOIC

OFFICE

OIC

OFFICE

CENTRAL

STORAGE

M/TLT

MICRO

BIOLOGY

JANITOR

30 GAL

W/H

F/TLT

SPECIMEN

TOILET

WAITING

RECEPTION

COPY/FILE

DISTRO

TECH

TECH

BLOOD

DRAW AREA

CORE

LAB

STAFF

LOUNGE/TEAM

CONFERENCE

ROOM

SIMULATION

CLASSROOM

CHIEF

ED&T

OFFICE

MDG

COMPUTER

CLASSROOM

MAIN

CLASSROOM

PANEL "A"

150 AMP

120/208v, 1Ø

PANEL "B"

150 AMP

120/208v, 1Ø

PANEL "C"

150 AMP

120/208v, 1Ø

PANEL "D"

150 AMP

120/208v, 1Ø

PANEL "E"

150 AMP

120/208v, 1Ø

PANEL "F"

150 AMP

120/208v, 1Ø

PANEL "G"

150 AMP

120/208v, 1Ø

PANEL "H"

150 AMP

120/208v, 1Ø

PANEL "i"

150 AMP

120/208v, 1Ø

PANEL "J"

150 AMP

120/208v, 1Ø

PANEL "K"

150 AMP

120/208v, 1Ø PANEL "L"

150 AMP

120/208v, 1Ø

PANEL "M"

150 AMP

120/208v, 1Ø

PANEL "N"

150 AMP

120/208v, 1Ø

PANEL "o"

150 AMP

120/208v, 1Ø

PANEL "P"

150 AMP

120/208v, 1Ø

EXERCISE

AREA

B-102

B-104

B-101

S-106

S-105

S-103

S-101d

S-101a

S-104

S-102 G-109aG-109b

A-107

G-108

A-106 G-107 G-106

G-102

G-101

G-103

G-103

A-101

A-102

G-105

G-104

A-105

A-104

A-103

K-107

K-103

K-104

K-104a

K-101

K-102

K-108 K-109

K-111 K-112

P-106

K-105a

K-105

P-101

A-108

P-102

P-103

EXIT B

W.P.

w/P.C.

EXIT B

W.P.

w/P.C.

EXIT B

EXIT BEXIT BEXIT BEXIT B

W.P.

w/P.C.

EXIT B

EXIT B

EXIT B

(2) 2" CONDUITS

UP THRU FLOOR

I/D UNIT

O/D UNIT

STAFF

TOILET

B-103

ON-CALL

ROOM

B-105

KITCHEN

B-104a

S-101c

S-101b

G-102a

K-105b

STAFF

TOILET

JANITOR

A-106 K-106

EXIT B

STORAGE

P-105

TECH

OFFICE

A-646

CRUTCH

SPLINT/STO

G-107

OIC

OFFICE

PATIENT

TOILET

i-2 i-2

M-2

M-2

N-2

N-2

M-2 o-2

M-2 o-2M-2M-2

P-2P-2

C-6

G

FI

B-6B-6

D-5

D-2

E-4

E-2

M-4

M-4

N-4

N-6

M-2

P-4

P-4

GFI

N-5

DN

DN

30 GAL

W/H G

FI

G

FI

N-6

G

FI

M-2

REFRG

o-4 o-4 o-2

D

N-7/9

A-6 +72" A.F.F.

S O S

M-2 i-2

COORDINATE HEIGHTS OF DATA

PORTS WITH CASEWORK AND

EQUIPMENT

TVTV

GFI

L-5

+72" A.F.F.

G

FI

G-4

B-4

C-6

A-2

B-2 B-2

B-2 B-2

B-2 B-2 A-2

B-2

B-2

A-2

C-2

C-2

C-2

C-2

C-2

D-2

C-2

D-2

E-2 F-2

G-2

G-2

D-2

S O S

D-4

C -5

G

FI

G-5

A-2 A-2

A-2 A-2

E-5

F-5

B-2 C-2 C-2

B-2

C-2

C-2

C-2

A-2

E-2

E-2

E-2

E-2

D-2 D-2

D-2 D-2 G-2

D-2 E-2

E-2 E-2

E-6

E-6

G-4

G-4 i-5

J-6

+72" A.F.F.

J-4

J-4

J-4

L-4

L-4

M-4

N-5

N-5

P-5

E-4

A-5

A-4

H-4

G-2

G-2

NOTE: DO NOT INSTALL

REMOTE HEADS IN CORRIDOR

INSTALL PLATES, TYP.

NOTE: DO NOT INSTALL

REMOTE HEADS IN CORRIDOR

INSTALL PLATES, TYP.

ON-CALL

ROOM

B-106

DN

A-2

A-6 A-5

B-6

C-5

C-5

220v TWIST

LOCK FLOOR

RECEPT FED

FROM MAIN

MDP PANEL

R E

FR

IG

R E

FR

IG

R E

FR

IG J-9J-8

REFRIG

L-6

M-8

DED

M-7

DED

L-7

DED

DED

P-7

P-7

A-6

E-4

GFI

S

IN

K

SINK S

IN

K

A-7

N-6 N-6

+48" A.F.F.

+48" A.F.F.

M-6

M-5 +48" A.F.F.

+48" A.F.F.

H-6

A-8

DED

DED

N-6

CEILING MOUNTED

RECPT AND J-BOX

FOR PROJECTOR

D-7

DED

G-6 o-6

PJ

DED

E-2 E-2E-2E-2

E-2 E-2E-2E-2

G-2 G-2G-2G-2

G-2 G-2G-2G-2

D-2 D-2

S O S

TV+72"

A.F.F.

P-7

C-6

B-4

D-4

E-7

G-4

L-8

N-4

P-4

2'-4"7"

" E-5 F-5

F-5

1'-5"

E-5

2'-0"3'-11"

4'-9"

1'-7"

E-5

+72" A.F.F.

L-5

A-6 A-5

M-5

REFRIG

J-7

GFI

GFI

GFI

J-5

D E

D

DED REFRIG

VALID

January 27, 2017

File details come from the government source that posted it.