MC METAL CLAD CABLE
CEILING LINE TO BE IN APPROVED
NOTE: ALL WIRING ABOVE T-GRID
ELEC:
ALL WIRING TO BE THHN OR BETTER
A
54321
B
C
D
E
B A
S E
C
IV
IL
E
N G
IN
E
E R
/D E
P U
T Y
C H
IE
F
E N
G
IN
E E
R
IN
G F
L
IG
H T
C
E P
C H
IE
F
C O
N T
R A
C T
S S
E C
T
IO
N
C E
P M
R E
C O
M M
E N
D E
D
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
R E
V D
A T
E E
N G
IN
E
E R
\D E
S
IG
N E
R
D R
A W
N B
Y
S C
A L E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
C O
N T
R A
C T
N U
M B
E R
D E
S
IG
N T
E A
M C
E P
M
U S
IN
G
A G
E N
C Y
C H
E C
K E
D B
Y
H O
E F
E R
W Y
S O
C K
I
A R
C H
IT
E
C T
S
/3
/2
JE DUNN + HWA
CLEARWATER, FL 33756
CONSULTING ENGINEER
1765 CARNEGIE AVENUE
Ph: (727) 505-9941
JAMES E. BRADLEY, P.E.
J E B
0' 4' 8' 16' 32'
1/8" = 1'-0"
0' 2' 4' 8' 16'
1/4" = 1'-0"
0' 1' 2'
3/4" = 1'-0"
4'0' 1'
1 1/2" = 1'-0"
2' 2'1'6"6"3"0' 6"
3" = 1'-0"
1'3"
NOT FOR CONSTRUCTION
2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930
TPF TYNDALL -
CONNECTING CORRIDOR
T Y
N D
A L
L A
F B
C O
N N
E C
T
IN
G C
O R
R
ID
O R
M
A G
N O
L
IA
C
IR
C L
E T
Y N
D A
L L
A F
B
F L
A S
I N
D
IC
A T
E D
J .L
.B
W -1
-R
-6
W -1
-D
-6
J A
M E
S E
B
R A
D L E
Y P
.E
J E
D U
N N
S U
B M
IT
T
A L
C
O R
R E
C T
E D
F
IN
A L
J .E
.B
A s i n d ic a te d E
L E
C P
L A
N
TCC-
E1.0
D e s ig n e r
A u th o r
C h e c k e r
W -1
-R
-6
W -1
-D
-6
S y m b o l
D es cr ip ti o n
T ra ck in g N o
A ct io n
D at e
T-GRID SYMBOLS
DUCT WITH FLEX DUCT DROP
TO CEILING REGISTERS (RETURN)
(UNLESS NOTED OTHERWISE)
8" FLEX DUCT - RETURN
(UNLESS NOTED OTHERWISE)
8" FLEX DUCT - SUPPLY
TO CEILING REGISTERS (SUPPLY)
OVERHEAD FIBERGLASS RIGID
DUCT WITH FLEX DUCT DROP
OVERHEAD FIBERGLASS RIGID
2'x2' SUPPLY AIR REGISTER
TROFFER PER SPECS.
2'x2' RETURN AIR REGISTER
2'x4' FLOURESCENT (2 TUBE 32w BULBS - 64w MAX)
EXHAUST FAN-100 CFM (UNLESS NOTED)
(NOTE: MANUAL VOLUME CONTROL DAMPERS
TO BE LOCATED AT EACH TAKE OFF)
(NOTE: MANUAL VOLUME CONTROL DAMPERS
TO BE LOCATED AT EACH TAKE OFF)
SCALE: 3/16"=1'-0"
ELEC PLAN
WATTS AREA SERVED WIRE BRK CKT A B CKT BRK WIRE AREA SERVED WATTS
Panel ID: "A"
WATTS AREA SERVED WIRE BRK CKT A B CKT BRK WIRE AREA SERVED WATTS
Panel ID: "B"
INCANDESCENT SP
FIXTURE (60w MAX)
WEATHERPROOF LIGHT
"PORCH" (W. PER SPEC)
HVAC DISCONNECT
(4x4 DOUBLE GANG)
PROGRAMMABLE A/C THERMOSTAT @ 53" A.F.F.
(80" BOX: 4x4 DOUBLE GANG)
ILLUMINATED EXIT SIGN AND EMERGENCY
LIGHTING COMBO w/BATTERY BACK-UP
J-BOX @ 80" A.F.F. FOR STROBE ONLY
EXHAUST FAN-100 CFM (UNLESS NOTED)
HORN/STROBE (48" BOX: 2x4 SINGLE GANG)
WIRED BACK TO HORN/STROBE (2x4 SINGLE GANG)
J-BOXES @ 48" & 80" A.F.F. FOR PULL STATION AND
EXHAUST FAN & LIGHT COMBO-100 CFM (UNLESS NOTED)
J-BOX @ 48" A.F.F. FOR PULL STATION - TO BE
J CEILING MOUNTED JUNCTION BOX
FLOOR MOUNTED JUNCTION BOXJ D
3-WAY SWITCH @ 48" A.F.F.
TELEPHONE JACK AT
42" A.F.F. (UNLESS NOTED)
DUPLEX RECEPTACLE @ 42" A.F.F. (UNLESS NOTED)
ELECTRICAL SYMBOLS
DUPLEX RECEPTACLE @ 16" A.F.F.
ELECTRICAL PANEL BOX 48" TO BOTTOM
WALL MOUNTED JUNCTION BOX 16" (UNLESS NOTED)
COMPUTER JACK @ 16" A.F.F. (UNLESS NOTED)
RECPTACLE 240v @ 16" A.F.F.
QUADPLEX RECEPTACLE @ 16" A.F.F. (UNLESS NOTED)
RECEPTACLE
DUPLEX RECEPTACLE
SWITCH @ 48" A.F.F.
CEILING MOUNTED
FLOOR DUPLEX
TELEPHONE JACK AT
16" A.F.F. (UNLESS NOTED)
TELEPHONE FLOOR J-BOX
S
J
C
3S
CEILING MOUNTED
FLOOR QUADPLEX
RECEPTACLE
QUADPLEX RECEPTACLE
H
S
EXIT B
W.P.
T
P
"FLOOD" (W. PER SPEC)
RECESSED INCANDESCENT
WEATHERPROOF LIGHT
LIGHT FIXTURE (40w MAX)
W.P.
(2 TUBE = 72w MAX.)
1'x4' FLUORESCENT - DIFFUSED - SURFACE MOUNTED
SWITCH w/OCCUPANCY SENSOR @ 48" A.F.F.
S
O S
CORRIDOR CORRIDORA-2 A-2 A-2A-2 A-2A-2 A-2 B-2B-2B-2B-2B-2B-2B-2B-2
B-4
W.P.
w/P.C.
W.P.
w/P.C.
W.P.
w/P.C.
W.P.
w/P.C.
A-4
DN
DN
B-2
B-2
B-2
B-2B-2A-2A-2
A-2
A-2
A-2
PANEL "B"
100 AMP
120/208v, 1Ø
PANEL "A"
100 AMP
120/208v, 1Ø
C A
N O
P Y
A B
O V
E
C A
N O
P Y
A B
O V
E
NOTE: DO NOT INSTALL
REMOTE HEADS IN CORRIDOR
INSTALL PLATES, TYP.NOTE: DO NOT INSTALL
REMOTE HEADS IN CORRIDOR
INSTALL PLATES, TYP.
VALID
January 27, 2017