43_17_TCCE1.0_Elec_Plan.pdf

PDF 366 KB Posted

Attached to
Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
Solicitation number
W9127S19Q6039
Issued by
Department of the Army Corps of Engineers Engineering District Little Rock

About this file

Part of Attachment I - As-Builts, 43-TPF Corridor

View the file

Other files for this federal contract opportunity

Other files attached to Tyndall AFB Temporary Modular Medical Facility, newest first.
File Type Posted
49_22__TLV2.0_Combined_Clinic_TPF_Low_Voltage_Systems_Notes_&_Details.pdf PDF
1-V1.07_SURVEY_PLAN.pdf PDF
1-V1.02_SURVEY_PLAN.pdf PDF
49_24__TPF2.0_Full_Building_Plan.pdf PDF
49_23__TCP1.4-PII_Combined_Clinic_TPF_RCP-PHASE_II.PDF PDF
1-V1.06_SURVEY_PLAN.pdf PDF
49_24__TPF6.0_Overall_Plumbing_Plan_-_Supply.pdf PDF
49_21__TFP3.1_Combined_Clinic_TPF_Fire_Suppression_Plan_Phase_1.pdf PDF
49_23__TCP1.1_Combined_Clinic_TPF_RCP.pdf PDF
49_25__TPFV1.0_COVER_SHEET_STAMPED.pdf PDF
49_25__TPFV8.0_CANOPY_ASSEMBLY_AND_FOOTING_DETAILS_STAMPED.pdf PDF
55_TQ3.11D_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_D.pdf PDF
55_TQ4.11_-_FFE_PLAN_-_TPF_PHASE_2.pdf PDF
49_21__TFP1.0_Combined_Clinic_TPF_Life_Safety_Narrative.pdf PDF
55_TQ4.11D_-_FFE_PLAN_-_TPF_PHASE_2,_AREA_D.pdf PDF
49_23__TCP1.5_Combined_Clinic_TPF_RCP.pdf PDF
49_25__TPFV2.0_STANDARD_RAMP_AND_STAIR_DETAILS_STAMPED.pdf PDF
49_24__TPF2.0-PI_Full_Building_Plan-Phase_1.pdf PDF
1-V1.01_SURVEY_PLAN.pdf PDF
49_23__TCP1.3_Combined_Clinic_TPF_RCP.pdf PDF
55_TQ4.01_-_FFE_JSN_LEGEND.pdf PDF
1-V1.05_SURVEY_PLAN.pdf PDF
36_12_TSM1.0_Mechanical_HVAC_Plan.pdf PDF
29_03_TNP4.0_Plumbing_Plan_-_DWV.pdf PDF
29_01_TNC1.0_Cover_Sheet-Notes.pdf PDF
29_03_TNP1.0_Plumbing_Schematics.pdf PDF
43_19_TCCX2.0_Roof_Drain_Details.pdf PDF
43_19_TCCX1.0_Building_Cross_Section.pdf PDF
29_07_TNFD1.0_Foundation_Plan_and_Details.pdf PDF
36_11_TSE1.1_Electrical_Panel_Schedules.pdf PDF
36_10_TSP3.0_Plumbing_Plan_-_Supply_Phase_1.pdf PDF
05_1-CU1.01_UTILITY_PLAN_-_PHASE_1.pdf PDF
43_20_TCCFD1.0_Foundation_Plan_and_Details.pdf PDF
36_09_TSA4.0-PII_Egress_Plan.pdf PDF
07_ES1-01_-_ELECTRICAL_SITE_PLAN_-_MEDICAL_CLINIC_BUILDING_1465.pdf PDF
36_11_TSE3.0-PII_Task_Lighting_Illumination_Plan_Phase_2.pdf PDF
36_10_TSP2.0_Plumbing_Schematics.pdf PDF
29_02_TNA3.0_Reflective_Ceiling_Plan.pdf PDF
36_14_TSFD1.0_Foundation_Plan_and_Details.pdf PDF
36_11_TSE4.0_MDP_-_One_Line_Diagram.pdf PDF
36_09_TSA3.0-PII_Reflective_Ceiling_Plan.pdf PDF
29_04_TNE1.0_Elec_Plan.pdf PDF
36_12_TSM1.0-PII_Mechanical_HVAC_Plan.pdf PDF
43_16_TCCA2.0_Floor_Plan.pdf PDF
36_10_TSP4.0_Plumbing_Plan_-_DWV_Phase_1.pdf PDF
36_11_TSE1.0-PII_Electrical_Plan.pdf PDF
36_09_TSA2.1_Interior_Elevations.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Combined_Synopsis_Solicitation_13Aug19.pdf PDF
Attachment_F_-_Codes_&_Criteria.pdf PDF
Attachment_D_-_DHA_LAN_WLAN_Guides.pdf PDF
Show all 50

Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MC METAL CLAD CABLE

CEILING LINE TO BE IN APPROVED

NOTE: ALL WIRING ABOVE T-GRID

ELEC:

ALL WIRING TO BE THHN OR BETTER

A

54321

B

C

D

E

B A

S E

C

IV

IL

E

N G

IN

E

E R

/D E

P U

T Y

C H

IE

F

E N

G

IN

E E

R

IN

G F

L

IG

H T

C

E P

C H

IE

F

C O

N T

R A

C T

S S

E C

T

IO

N

C E

P M

R E

C O

M M

E N

D E

D

R E

C O

M M

E N

D E

D

A P

P R

O V

E D

R E

V D

A T

E E

N G

IN

E

E R

\D E

S

IG

N E

R

D R

A W

N B

Y

S C

A L E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

C O

N T

R A

C T

N U

M B

E R

D E

S

IG

N T

E A

M C

E P

M

U S

IN

G

A G

E N

C Y

C H

E C

K E

D B

Y

H O

E F

E R

W Y

S O

C K

I

A R

C H

IT

E

C T

S

/3

/2

JE DUNN + HWA

CLEARWATER, FL 33756

CONSULTING ENGINEER

1765 CARNEGIE AVENUE

Ph: (727) 505-9941

JAMES E. BRADLEY, P.E.

J E B

0' 4' 8' 16' 32'

1/8" = 1'-0"

0' 2' 4' 8' 16'

1/4" = 1'-0"

0' 1' 2'

3/4" = 1'-0"

4'0' 1'

1 1/2" = 1'-0"

2' 2'1'6"6"3"0' 6"

3" = 1'-0"

1'3"

NOT FOR CONSTRUCTION

2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930

TPF TYNDALL -

CONNECTING CORRIDOR

T Y

N D

A L

L A

F B

C O

N N

E C

T

IN

G C

O R

R

ID

O R

M

A G

N O

L

IA

C

IR

C L

E T

Y N

D A

L L

A F

B

F L

A S

I N

D

IC

A T

E D

J .L

.B

W -1

-R

-6

W -1

-D

-6

J A

M E

S E

B

R A

D L E

Y P

.E

J E

D U

N N

S U

B M

IT

T

A L

C

O R

R E

C T

E D

F

IN

A L

J .E

.B

A s i n d ic a te d E

L E

C P

L A

N

TCC-

E1.0

D e s ig n e r

A u th o r

C h e c k e r

W -1

-R

-6

W -1

-D

-6

S y m b o l

D es cr ip ti o n

T ra ck in g N o

A ct io n

D at e

T-GRID SYMBOLS

DUCT WITH FLEX DUCT DROP

TO CEILING REGISTERS (RETURN)

(UNLESS NOTED OTHERWISE)

8" FLEX DUCT - RETURN

(UNLESS NOTED OTHERWISE)

8" FLEX DUCT - SUPPLY

TO CEILING REGISTERS (SUPPLY)

OVERHEAD FIBERGLASS RIGID

DUCT WITH FLEX DUCT DROP

OVERHEAD FIBERGLASS RIGID

2'x2' SUPPLY AIR REGISTER

TROFFER PER SPECS.

2'x2' RETURN AIR REGISTER

2'x4' FLOURESCENT (2 TUBE 32w BULBS - 64w MAX)

EXHAUST FAN-100 CFM (UNLESS NOTED)

(NOTE: MANUAL VOLUME CONTROL DAMPERS

TO BE LOCATED AT EACH TAKE OFF)

(NOTE: MANUAL VOLUME CONTROL DAMPERS

TO BE LOCATED AT EACH TAKE OFF)

SCALE: 3/16"=1'-0"

ELEC PLAN

WATTS AREA SERVED WIRE BRK CKT A B CKT BRK WIRE AREA SERVED WATTS

Panel ID: "A"

WATTS AREA SERVED WIRE BRK CKT A B CKT BRK WIRE AREA SERVED WATTS

Panel ID: "B"

INCANDESCENT SP

FIXTURE (60w MAX)

WEATHERPROOF LIGHT

"PORCH" (W. PER SPEC)

HVAC DISCONNECT

(4x4 DOUBLE GANG)

PROGRAMMABLE A/C THERMOSTAT @ 53" A.F.F.

(80" BOX: 4x4 DOUBLE GANG)

ILLUMINATED EXIT SIGN AND EMERGENCY

LIGHTING COMBO w/BATTERY BACK-UP

J-BOX @ 80" A.F.F. FOR STROBE ONLY

EXHAUST FAN-100 CFM (UNLESS NOTED)

HORN/STROBE (48" BOX: 2x4 SINGLE GANG)

WIRED BACK TO HORN/STROBE (2x4 SINGLE GANG)

J-BOXES @ 48" & 80" A.F.F. FOR PULL STATION AND

EXHAUST FAN & LIGHT COMBO-100 CFM (UNLESS NOTED)

J-BOX @ 48" A.F.F. FOR PULL STATION - TO BE

J CEILING MOUNTED JUNCTION BOX

FLOOR MOUNTED JUNCTION BOXJ D

3-WAY SWITCH @ 48" A.F.F.

TELEPHONE JACK AT

42" A.F.F. (UNLESS NOTED)

DUPLEX RECEPTACLE @ 42" A.F.F. (UNLESS NOTED)

ELECTRICAL SYMBOLS

DUPLEX RECEPTACLE @ 16" A.F.F.

ELECTRICAL PANEL BOX 48" TO BOTTOM

WALL MOUNTED JUNCTION BOX 16" (UNLESS NOTED)

COMPUTER JACK @ 16" A.F.F. (UNLESS NOTED)

RECPTACLE 240v @ 16" A.F.F.

QUADPLEX RECEPTACLE @ 16" A.F.F. (UNLESS NOTED)

RECEPTACLE

DUPLEX RECEPTACLE

SWITCH @ 48" A.F.F.

CEILING MOUNTED

FLOOR DUPLEX

TELEPHONE JACK AT

16" A.F.F. (UNLESS NOTED)

TELEPHONE FLOOR J-BOX

S

J

C

3S

CEILING MOUNTED

FLOOR QUADPLEX

RECEPTACLE

QUADPLEX RECEPTACLE

H

S

EXIT B

W.P.

T

P

"FLOOD" (W. PER SPEC)

RECESSED INCANDESCENT

WEATHERPROOF LIGHT

LIGHT FIXTURE (40w MAX)

W.P.

(2 TUBE = 72w MAX.)

1'x4' FLUORESCENT - DIFFUSED - SURFACE MOUNTED

SWITCH w/OCCUPANCY SENSOR @ 48" A.F.F.

S

O S

CORRIDOR CORRIDORA-2 A-2 A-2A-2 A-2A-2 A-2 B-2B-2B-2B-2B-2B-2B-2B-2

B-4

W.P.

w/P.C.

W.P.

w/P.C.

W.P.

w/P.C.

W.P.

w/P.C.

A-4

DN

DN

B-2

B-2

B-2

B-2B-2A-2A-2

A-2

A-2

A-2

PANEL "B"

100 AMP

120/208v, 1Ø

PANEL "A"

100 AMP

120/208v, 1Ø

C A

N O

P Y

A B

O V

E

C A

N O

P Y

A B

O V

E

NOTE: DO NOT INSTALL

REMOTE HEADS IN CORRIDOR

INSTALL PLATES, TYP.NOTE: DO NOT INSTALL

REMOTE HEADS IN CORRIDOR

INSTALL PLATES, TYP.

VALID

January 27, 2017

File details come from the government source that posted it.