08_T1.10_-_TELECOM_SITE_PLAN_-_CONSTRUCTION_PHASE.pdf
PDF 678 KB Posted
- Attached to
- Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
- Solicitation number
- W9127S19Q6039
About this file
Part of Attachment B1 - Additional Utility Plans
View the file
Other files for this federal contract opportunity
Show all 50
Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONC.
M
A B
A A
B A
ABA
ABA
ABA
ABA
ABA
A B
A A
B A
A B
A A
B A
A B
A A
B A
A B
A A
B A
A B
A A
B A
AREA IS NOT WITHIN
SCOPE OF WORK
10 11
13 14
20 21
LI
TT
LE
R
O C
K D
IV
IS
IO
N
LI
TT
LE
R
O C
K , A
R K
A N
S A
S
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
A
54321
B
C
D
E
54321
B A
S E
C
IV
IL
E
N G
IN
E
E R
/D E
P U
TY
C H
IE
F
E N
G
IN
E E
R
IN
G F
LI
G
H T
(C E
P
C H
IE
F
C O
N
TR
A C
TS
S
E C
TI
O
N (C
E P
M
R E
C O
M M
E N
D E
D
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
R E
V D
A
TE
E N
G
IN
E E
R \D
E S
IG
N
E R
D R
A W
N B
Y
S C
A
LE
S O
LI
C
IT
A
TI
O
N N
U M
B E
R
C O
N
TR
A C
T N
U M
B E
R D
E S
IG
N
T E
A M
JE
D
U N
N
U S
IN
G
A G
E N
C Y
C H
E C
K E
D B
Y
H O
E
FE
R W
Y S
O C
K I
A R
C H
IT
E
C
TS
/0
1/
JE DUNN + HWA
NATIONAL HEALTHCARE DEISGN-BUILD TEAM
S U
B M
I T T
A L
C O
R R
E C
T E
D F
IN
A
L
U S
AF
S S
R
6/
/2
:5 8:
0'
-0
C :\U se rs
\k la m pl ey \D oc um en ts
\S S
R _T
E C
H _T
Y N
D A
LL
_C en tr al _2
5_ kl am pl ey
.r vt
T E
LE
C
O M
S
IT
E P
LA
N
C
O N
S T
R U
C T
IO
N
P H
A S
E
TY
ND
AL
L
AF
B
T1.10
M
AG
NO
LI
A
CI
RC
LE
TY
ND
AL
L
AF
B, F
L
BH
L
JD
C
W
5-
-R
-6
W
5-
-D
-6
KEYED NOTES
APPROXIMATE LOCATION OF DIRECT BURIED 600-PAIR COPPER SPLICE.
CONTACT BASE COMM FOR EXACT LOCATION. COORDINATE WITH BASE
COMM ON EXACT CABLE NUMBERS ON EXISTING 600-PAIR TO SPLICE
INTO. FURNISH, INSTALL, TERMINATE, PRETEST, AND POST-TEST NEW
100-PAIR COPPER CABLE ROUTED FROM THIS LOCATION TO EXISTING
CLINIC DATA CENTER INDICATED BY KEYED NOTE #9. TERMINATE ALL
100-PAIR COPPER CABLE ON BACK WALL IN PROTECTED ENTRANCE
TERMINAL PER KEYED NOTE #5.
USE EXISTING SPARE 4" CONDUIT NEAR DIRECT BURIED SPLICE BOX
INDICATED BY KEYED NOTE #1 THAT IS CURRENTLY ROUTED INTO
EXISTING DATA CENTER INDICATED BY KEYED NOTE #9.
INDICATES THE LOCATION OF EXISTING LB'S ON EXTERIOR WALL OF THE
MAIN CLINIC. CONTRACTOR TO ROUTE NEW 100-PAIR COPPER CABLE
FROM EXISTING COPPER SPLICE BOX INDICATED BY KEYED NOTE #1, 12-
STRAND SINGLE MODE WITH 25-PAIR COPPER CABLING FROM TPF, AND
12-STRAND SINGLE MODE WITH 25-PAIR COPPER CABLING FROM
COMMAND TPF INTO THE EXISTING MAIN CLINIC THROUGH THIS EXISTING
ENTRY POINT. CONTRACTOR TO COORDINATE WITH BASE COMM ON
WHICH LB TO UTILIZE FOR NEW CABLING. CONTRACTOR WILL HAVE TO
DEMO A PORTION OF CONDUIT EXTENDING FROM THE DESIGNATED LB
INTO THE GROUND TO ACCEPT THE NEW CONDUIT EXTENDING FROM
NEW PULL BOX INDICATED BY KEYED NOTE #18.
INDICATES THE LOCATION OF (4) 4" CONDUIT STUBS WITHIN EXISTING
DATA CENTER THAT EXTEND FROM THE EXTERIOR LB'S INDICATED BY
KEYED NOTE #3. CONTRACTOR TO COORDINATE WITH BASE COMM ON
WHICH CONDUIT STUB TO USE PRIOR TO INSTALLATION.
FURNISH AND INSTALL A WALL MOUNTED PROTECTIVE ENCLOSURE
CAPABLE OF SUPPORTING 100-PAIR COPPER CABLE. COORDINATE WITH
BASE COMM ON EXACT TERMINATION REQUIREMENTS.
FURNISH AND INSTALL A NEW 2-POST 19" WIDE RACK FOR NEW
INCOMING 100-PAIR COOPER CABLE THAT IS TERMINATED AT WALL
MOUNTED PROTECTIVE ENCLOSURE INDICATED BY KEYED NOTE #5.
PROVIDE NEW COPPER PATCH PANELS AS REQUIRED.
FURNISH AND INSTALL A 25-PAIR COPPER CABLE FROM THE NEW 2-POST
COPPER RACK INDICATED BY KEYED NOTE #6 TO EXISTING FIBER
DISTRIBUTION RACK INDICATED BY KEYED NOTE #8. COORDINATE WITH
BASE COMM ON EXACT LOCATION AND TERMINATION REQUIREMENTS
PRIOR TO INSTALLATION.
INDICATES LOCATION OF THE EXISTING FIBER DISTRIBUTION RACK.
COORDINATE WITH BASE COMM ON EXACT TERMINATION
REQUIREMENTS. PROVIDE NEW COPPER PATCH PANELS AND FIBER
OPTIC DISTRIBUTION PANELS AS REQUIRED.
INDICATES THE LOCATION OF THE EXISTING DATA CENTER.
ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL (1) 4" PVC RIGID
CONDUITS WITH PULL STRING AT 3' BELOW GRADE FROM NEW PULL
BOX INDICATED BY KEYED NOTE #18 FOR CONTINUATION TO EXISTING
MAIN CLINIC DATA CENTER INDICATED BY KEYED NOTE #9.
CONTRACTOR TO ROUTE CABLING TO TPF COMM ROOM INDICATED BY
KEYED NOTE #12.
CONTRACTOR SHALL FURNISH AND INSTALL A 12 STRAND SINGLE
MODE FIBER WITH INNERDUCT AND 25-PAIR COPPER FROM THE MAIN
CLINIC DATA CENTER INDICATED BY KEYED NOTE #9 TO THE TPF
TELECOMMUNICATIONS CLOSET INDICATED BY KEYED NOTE #12.
COORDINATE EXACT TERMINATION POINT WITHIN THE TPF WITH TPF
MANUFACTURER.
INDICATES LOCATION OF TPF IDF/DEMARCATION POINT. TERMINATE
FIBER IN EQUIPMENT RACK.
CONTRACTOR TO FURNISH AND INSTALL A BELOW GRADE PULL BOX
NEXT TO EXTERIOR WALL AT THIS LOCATION TO ROUTE FIBER AND
COPPER UP EXTERIOR WALL AND INTO THE BUILDING.
CONTRACTOR TO ROUTE CONDUIT UP EXTERIOR WALL TO ABOVE
CEILING HEIGHT. CONTRACTOR SHALL ALSO FURNISH AND INSTALL
EXTERIOR WALL MOUNTED JUNCTION BOX TO BE USED AS A PULL POINT
INTO THE FACILITY.
ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL (1) 4" PVC RIGID
CONDUITS WITH PULL STRING AT 3' BELOW GRADE FROM NEW PULL
BOX INDICATED BY KEYED NOTE #18 FOR CONTINUATION TO EXISTING
MAIN CLINIC DATA CENTER INDICATED BY KEYED NOTE #9.
CONTRACTOR TO ROUTE CABLING TO COMMAND TPF COMM ROOM
INDICATED BY KEYED NOTE #17.
CONTRACTOR SHALL FURNISH AND INSTALL A 12 STRAND SINGLE
MODE FIBER WITH INNERDUCT AND 25-PAIR COPPER FROM THE MAIN
CLINIC DATA CENTER INDICATED BY KEYED NOTE #9 TO THE COMMAND
TPF TELECOMMUNICATIONS CLOSET INDICATED BY KEYED NOTE #17.
COORDINATE EXACT TERMINATION POINT WITHIN THE TPF WITH TPF
MANUFACTURER.
INDICATES LOCATION OF COMMAND TPF IDF/DEMARCATION POINT.
TERMINATE FIBER IN EQUIPMENT RACK.
PROVIDE NEW PULL BOX CAPABLE OF ACCEPTING (5) 4" CONDUITS.
PROVIDE (1) 4" CONDUIT FROM NEW PULL BOX INDICATED BY KEYED
NOTE #18 TO EXISTING LB INDICATED BY KEYED NOTE #3 THAT WILL BE
DESIGNATED TO ACCEPT ALL NEW CABLING FROM TPF AND COMMAND
TPF.
PROVIDE (1) 25-PAIR COPPER CABLE FROM THE EXISTING DATA CENTER
INDICATED BY KEYED NOTE #9 TO EXISTING MILCON COMM ROOM 1P148
INDICATED BY KEYED NOTE #22. DEMOLITION CONTRACTOR IS TO
PROPERLY IDENTIFY CABLING AND SHALL ENSURE THAT IT IS
PROTECTED DURING ALL LEVELS OF RENOVATION AFTER INSTALLATION
IS COMPLETE. DEMOLITION CONTRACTOR SHALL BARE ALL COST TO
DAMAGE OF NEWLY INSTALLED COPPER BACK BONE INFRASTRUCTURE.
PROVIDE (1) 25-PAIR COPPER CABLE FROM THE EXISTING DATA CENTER
INDICATED BY KEYED NOTE #9 TO EXISTING MILCON COMM ROOM 1R105
INDICATED BY KEYED NOTE #23. DEMOLITION CONTRACTOR IS TO
PROPERLY IDENTIFY CABLING AND SHALL ENSURE THAT IT IS
PROTECTED DURING ALL LEVELS OF RENOVATION AFTER INSTALLATION
IS COMPLETE. DEMOLITION CONTRACTOR SHALL BARE ALL COST TO
DAMAGE OF NEWLY INSTALLED COPPER BACK BONE INFRASTRUCTURE.
INDICATES LOCATION OF EXISTING MILCON COMM ROOM 1P148.
INDICATES LOCATION OF EXISTING MILCON COMM ROOM 1R105.
EXISTING FIBER INFRASTRUCTURE CURRENTLY SERVING THE MILCON
ADDITION IS TO BE PROPERLY IDENTIFIED AND SHALL BE PROTECTED
DURING ALL LEVELS OF RENOVATION. DEMOLITION CONTRACTOR
SHALL BARE ALL COST TO DAMAGE OF EXISTING FIBER
INFRASTRUCTURE.
GENERAL NOTESGENERAL NOTES
PATHWAYS SHOWN ARE DEDICATED FOR TECHNOLOGY LOW
VOLTAGE SYSTEMS ONLY. PROVIDE FIRESTOPPING WHEN
PENETRATING RATED WALLS TO MATCH WALL TYPE.
THESE DRAWINGS ARE DIAGRAMMTIC IN NATURE TO SHOW INTENT OF
PATHWAY AND CONNECTIVITY REQUIREMENTS. REFER TO CIVIL
ENGINEERING DRAWINGS FOR UNDERGROUND UTILITY COORDINATION
TO DETERMINE EXACT LOCATION AND PLACEMENT OF UNDERGROUND
PATHWAY.
1.
2.
0 15' 45' 60'30'
PLAN NORTH 1" = 30'-0"1 LEVEL 1 - TELECOM SITE PLAN
Sy m bo l
D es cr ip tio n
T ra ck in g N o.
A ct io n D at e
A m en dm en t 0
/1 5/
A m en dm en t 0
/2 8/
June 28, 2017 mtomlin Text Box PATHWAY FOR 25 PAIR COPPER FROM EXISTING DATA CENTER INIDICATED BY KEY NOTE #9 ON SITE PLAN TO MILCON COMM ROOMS 1P148 AND 1R105 IS SCHEMATIC ONLY. LV CONTRACTOR WILL AUDIT SITE AND DETERMINE BEST PATHWAY TO BOTH MILCON COMM ROOMS FROM EXISTING DATA CENTER. LV CONTRACTOR WILL NEED TO COORDINATE WITH BASE COMM TO ENSURE NO LOSS OF SERVICE TO EITHER MILCON COMM ROOMS. LV CONTRACTOR WILL DOCUMENT PATHWAY ON AS-BUILT SUBMITTAL PACKAGE.
mtomlin Ellipse mtomlin Text Box mtomlin Ellipse mtomlin Text Box mtomlin Ellipse mtomlin Text Box
File details come from the government source that posted it.