36_09_TSA2.0_Floor_Plan.pdf

PDF 3 MB Posted

Attached to
Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
Solicitation number
W9127S19Q6039
Issued by
Department of the Army Corps of Engineers Engineering District Little Rock

About this file

Part of Attachment I - As-Builts, 36-TPF South Ambulance

View the file

Other files for this federal contract opportunity

Other files attached to Tyndall AFB Temporary Modular Medical Facility, newest first.
File Type Posted
49_25__TPFV7.0_RAMP_STEP_AND_PLATFORM_CONNECTION_DETAILS_STAMPED.pdf PDF
1-V1.03_SURVEY_PLAN.pdf PDF
49_23__TCP1.4_Combined_Clinic_TPF_RCP.pdf PDF
1-V1.08_SURVEY_PLAN.pdf PDF
49_21__TFP4.2_Combined_Clinic_TPF_Fire_Alarm_Plan_Phase_2.pdf PDF
49_24__TPF4.0_Overall_Supply_Plumbing_Schematic.pdf PDF
49_24__TPF5.0_Overall_DWV_&_Waste_Schematic.pdf PDF
49_25__TPFV6.0_CANOPY_FOOTING_DETAILS_STAMPED.pdf PDF
55_TQ3.02_-_FFE_JSN_LEGEND.pdf PDF
49_21__TFP2.0_Combined_Clinic_TPF_Life_Safety_Plan.pdf PDF
49_24__TPF1.0_Full_Building_Elevations.pdf PDF
49_23__TCP1.4-PI_Combined_Clinic_TPF_RCP-PHASE_1.pdf PDF
49_21__TFP3.2_Combined_Clinic_TPF_Fire_Suppression_Plan_Phase_2.pdf PDF
49_21__TFP4.1_Combined_Clinic_TPF_Fire_Alarm_Plan_Phase_1.pdf PDF
56_SGT.03_TEMP_SIGNAGE_TPF_PHASE_2.pdf PDF
55_TQ3.01_-_FFE_JSN_LEGEND.pdf PDF
56_SGT.02_TEMP_SIGNAGE_TPF_PHASE_1.pdf PDF
49_22__TLV1.0_Combined_Clinic_TPF_LV_Systems_Notes_&_Details.pdf PDF
55_TQ4.11D_-_FFE_PLAN_-_TPF_PHASE_2,_AREA_D.pdf PDF
49_23__TCP1.5_Combined_Clinic_TPF_RCP.pdf PDF
49_25__TPFV2.0_STANDARD_RAMP_AND_STAIR_DETAILS_STAMPED.pdf PDF
49_24__TPF2.0-PI_Full_Building_Plan-Phase_1.pdf PDF
08_T1.10_-_TELECOM_SITE_PLAN_-_CONSTRUCTION_PHASE.pdf PDF
43_17_TCCE2.0_Illumination_Plan.pdf PDF
29_02_TNA2.1_Interior_Elevations.pdf PDF
Attachment_H_-_TPF_Placement_Area.pdf PDF
36_09_TSA4.0_Egress_Plan.pdf PDF
36_08_TSC1.0_Cover_Sheet.pdf PDF
36_11_TSE1.0_Electrical_Plan.pdf PDF
43_18_TCCM1.0_MECHANICAL_HVAC_PLAN.pdf PDF
08_T6.05-TECHNOLOGY_SITE_RISER_DIAGRAM.pdf PDF
36_13_TSX1.0_Building_Cross_Section.pdf PDF
43_15_TCCC1.0_Cover_Sheet_-_Notes.pdf PDF
28_CS.43_-_DWG_INDEX_PKG_I_VOL_3_OF_4.pdf PDF
29_04_TNE1.1_Electrical_Panel_Schedules.pdf PDF
36_10_TSP2.0_Plumbing_Schematics.pdf PDF
29_02_TNA3.0_Reflective_Ceiling_Plan.pdf PDF
36_14_TSFD1.0_Foundation_Plan_and_Details.pdf PDF
36_11_TSE4.0_MDP_-_One_Line_Diagram.pdf PDF
36_09_TSA3.0-PII_Reflective_Ceiling_Plan.pdf PDF
29_04_TNE1.0_Elec_Plan.pdf PDF
36_12_TSM1.0-PII_Mechanical_HVAC_Plan.pdf PDF
43_16_TCCA2.0_Floor_Plan.pdf PDF
36_10_TSP4.0_Plumbing_Plan_-_DWV_Phase_1.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Response_to_Questions_13Aug19.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Combined_Synopsis_Solicitation_13Aug19.pdf PDF
Attachment_E_-_Installation_Facility_Standards_&_Plans.pdf PDF
Tyndall_TMMF_Statement_of_Work_10Jul19.pdf PDF
Attachment_F_-_Codes_&_Criteria.pdf PDF
Attachment_D_-_DHA_LAN_WLAN_Guides.pdf PDF
Show all 50

Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE: 3/16"=1'-0"

FLOOR PLAN

DOOR SCHEDULE

# SIZE DESCRIPTION QTY HEADER JACKS KINGS COMMENTS

36"x80" EXT DOOR - STEEL - FLUSH 2 TRPL 2x4 1 1 w/20"x30" SAFETY GLASS VIEW PANEL, STEEL FRAME, CLOSER, PANIC HARDWARE, THRESHOLD, WEATHERSTRIPPINGA

40 SNGL 2x4 - 1

B

WINDOW SCHEDULE

# SIZE DESCRIPTION QTY HEADER JACKS KINGS COMMENTS

EXT WINDOW - SNGL HUNG - VERT SLIDING 4 TRPL 2x4 1 1

VINYL WHITE FRAME / DIG TINTED LOW-E GLASS w/ROLLER SHADES1

36"x80" INT. DOOR - SOLD CORE - FLUSH w/STEEL FRAME, KEYED LEVER LOCKSET

6 SNGL 2x4 - 1

C

36"x80" w/STEEL FRAME, PRIVACY LEVER LOCKSET

D

36"x60"

INT. DOOR - SOLD CORE - FLUSH

EXT WINDOW - SNGL HUNG - VERT SLIDING 4 TRPL 2x4 - 1

VINYL WHITE FRAME / DIG TINTED LOW-E GLASS w/ROLLER SHADES2

24"x60"

INT WINDOW - HORZ SLIDING - RECEPTIONIST 2 SNGL 2x4 - 1

MILL/CLEAR3

BOTTOM OF WINDOW

AT 34" A.F.F.

60"x36"

48"x80" EXT DOOR - STEEL - FLUSH 1 TRPL 2x6 1 1 w/20"x30" SAFETY GLASS VIEW PANEL, STEEL FRAME, CLOSER, PANIC HARDWARE, THRESHOLD, WEATHERSTRIPPING

(2) 2x4 SPF #2 THIS HALF

(3) 2x4 SPF #2 THIS HALF

(2) 2x6 SPF #2 THIS HALF

(4) 2x4 SPF #2 THIS HALF

PER APPROVED PACKAGE

COLUMN STRAPPING SCHEDULE

INSTALL TWO STEEL STRAPS AT EACH STUD OF EACH COLUMN.

ALL COLUMN STUDS SHALL BE GLUE/NAILED TOGETHER.

COLUMN STUDS SHALL NOT BE NOTCHED OR BORED.

PVA GLUE WITH 100% COVERAGE SHALL BE USED.

ADD RIDGE BEAM BEARING STIFFENER

STRUCTURAL HEADER ABOVE OPENING

NOTES:

1.

3.

2.

E

G

C

A

(3) 2x4 SPF #2 EACH HALF

(2) 2x4 SPF #2 EACH HALF

(2) 2x6 SPF #2 EACH HALF

(4) 2x4 SPF #2 EACH HALFF

H

D

B

(3) 2x6 SPF #2 THIS HALFJ (3) 2x6 SPF #2 EACH HALFK

A

54321

B

C

D

E

B A

S E

C

IV

IL

E

N G

IN

E

E R

/D E

P U

T Y

C H

IE

F

E N

G

IN

E E

R

IN

G F

L

IG

H T

C

E P

C H

IE

F

C O

N T

R A

C T

S S

E C

T

IO

N

C E

P M

R E

C O

M M

E N

D E

D

R E

C O

M M

E N

D E

D

A P

P R

O V

E D

R E

V D

A T

E E

N G

IN

E

E R

\D E

S

IG

N E

R

D R

A W

N B

Y

S C

A L

E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

C O

N T

R A

C T

N U

M B

E R

D E

S

IG

N T

E A

M C

E P

M

U S

IN

G

A G

E N

C Y

C H

E C

K E

D B

Y

H O

E F

E R

W Y

S O

C K

I A

R C

H

IT

E C

T S

3/

/2

JE DUNN + HWA

CLEARWATER, FL 33756

CONSULTING ENGINEER

1765 CARNEGIE AVENUE

Ph: (727) 505-9941

JAMES E. BRADLEY, P.E.

J E B

0' 4' 8' 16' 32'

1/8" = 1'-0"

0' 2' 4' 8' 16'

1/4" = 1'-0"

0' 1' 2'

3/4" = 1'-0"

4'0' 1'

1 1/2" = 1'-0"

2' 2'1'6"6"3"0' 6"

3" = 1'-0"

1'3"

2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930

TPF TYNDALL - SOUTH

AMBULANCE SERVICES BLDG

A S

I N

D

IC

A T

E D

J A

M E

S E

B

R A

D L

E Y

P

.E

W

-1

-R -6

W

-1

-D -6

J .L

.B

J E

D U

N N

J .E

.B

S U

B M

IT

T

A L

C O

R R

E C

T E

D F

IN

A

L A

M E

N D

M E

N T

& ASSOCIATES

HILBORN, WERNER, CARTER

1627 SOUTH MYRTLE AVE.

CLEARWATER, FLORIDA 33756

THIRD PARTY:

F L

O O

R P

L A

N

T Y

N D

A L

L A

F B

A M

B U

L A

N C

E S

E R

V

IC

E S

B L

D G

TSA2.0

M

A G

N O

L

IA

C

IR

C L

E T

Y N

D A

L L

A F

B

F L

S y m b o l D es cr ip ti o n

T ra ck in g N o

A ct io n

D at e

1 TRPL 2x4 1 136"x80" w/STEEL FRAME, CLOSER, PANIC HARDWARE, THRESHOLD, WEATHERSTRIPPINGE

EXT DOOR - STEEL - FLUSH -

2 SNGL 2x448"x80" w/STEEL FRAME, KEYED LEVER LOCKSETF

INT. DOOR - SOLD CORE - FLUSH

1 HOUR

FIRE

50 STC

SOUND

GENERIC

WALLS AND INTERIOR PARTITIONS, WOOD-FRAMED

GYPSUM WALLBOARD, WOOD STUDS

ONE LAYER 5/8" TYPE X PLAIN OR PREDECORATED GYPSUM WALLBOARD,

WATER-RESISTANT GYPSUM BACKING BOARD, OR GYPSUM VENEER BASE

APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF 2 X 4 WOOD

STUDS 16" O.C.; JOINTS OF SQUARE EDGE, BEVEL EDGE OR PREDECORATED

WALLBOARD MAY BE LEFT EXPOSED. NOTE: ONE SIDE OF WALL MUST HAVE

RC-1 CHANNELS

JOINTS STAGGERED 16" ON OPPOSITE SIDES. (LOAD-BEARING)

Thickness: 5 1/4"

Approx. Weight: 7 psf

Fire Test: UL R1319-4, -6, 6-17-52;

UL R2717-39, 1-20-66;

UL R3501-52, 3-15-66,

UL Design U305;

ULC Design W301

Sound Test: OR 64-8, 2-4-64

GA FILE NO. WP 3605

UL DESIGN U305

50 STC SOUND

w/BATT INSULATION

AND RC-1 CHANNELS

1 HOUR

FIRE

34 to 46 STC

SOUND

GENERIC

WALLS AND INTERIOR PARTITIONS, WOOD-FRAMED

GYPSUM WALLBOARD, WOOD STUDS

ONE LAYER 5/8" TYPE X PLAIN OR PREDECORATED GYPSUM WALLBOARD,

WATER-RESISTANT GYPSUM BACKING BOARD, OR GYPSUM VENEER BASE

APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF 2 X 4 WOOD

STUDS 16" O.C.; JOINTS OF SQUARE EDGE, BEVEL EDGE OR PREDECORATED

WALLBOARD MAY BE LEFT EXPOSED.

JOINTS STAGGERED 16" ON OPPOSITE SIDES. (LOAD-BEARING) Thickness: 4 7/8"

Approx. Weight: 7 psf

Fire Test: UL R1319-4, -6, 6-17-52;

UL R2717-39, 1-20-66;

UL R3501-52, 3-15-66,

UL Design U305;

ULC Design W301

Sound Test: OR 64-8, 2-4-64

GA FILE NO. WP 3605

UL DESIGN U305

46 STC SOUND w/BATT

INSULATION

NOTE: SEE DETAIL ON SHEET TSM1.0 FOR MORE

INFORMATION REGARDING CEILING HEIGHT AND

CONSTRUCTION IN EXCERCISE AREA.

2 SNGL 2x4 - 136"x80" INT. DOOR - SOLD CORE - FLUSH w/STEEL FRAME, PUSH/PULL, CLOSERG

WALL MOUNTED MINI-SPLIT

A/C UNIT; (COOLING ONLY)

FREDRICH (350 CFM); BOTTOM

OF UNIT TO BE AT 80" A.F.F.

OUTDOOR CONDENSING UNT; FREDRICH

#MR12CH; OUTSIDE CONDENSING UNIT

(12,300 BTUH COOLING ONLY); ALL

CONDENSATE LINES AND WIRING TO

INDOOR UNITS ARE TO BE SITE

INSTALLED BY SMM; UNIT IS SHIPPED

LOOSE AND SITE INSTALLED

DN

LINE PLENUM WALL WITH

MIN. 1/2" GYPSUM, TYP.

3/0x5/0VS

11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8"

6"

11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8"

3'-10"

11'-2"

186'-8"

A B C D E F G H i J K L M N o P

4/0x6/8

3/0 x6

/8

3/0x6/8

3/0x6/8

3/0x6/8

3/0x6/8

/0 x6 /8

3/0x6/8

/0 x6 /8

3/0x6/8

3/0x6/8

/0 x6 /8

3/0x6/83/0x6/8

/0 x6 /8

/0 x6 /8

/0 x6 /8

/0 x6 /8

3/0x6/8

3/0x6/8

42"G.B.

"G .B

"V .G

.B

"G .B

36"G.B.

18"V.G.B.

/0 x6 /8

3/0x6/8

3/0x6/8

3/0x6/8

/0 x6 /8

/0 x6 /8

3/0x6/8

/0 x6 /8

/0 x6 /8

/0 x6 /8

/0 x6 /8

/0 x6 /8

3/0x6/8 3/0x6/8

3/0x6/8

/0 x6 /8

/0 x6 /8

STORAGE

/2

/2

10'-10" 6'-6" 8'-0" 12'-8" 8'-0"7'-0" 14'-6" 5'-0" 19'-7"

3/0x6/8

10'-0" 10'-0" 9'-5"

10'-10"23'-8"29'-4"5'-10"5'-0"9'-9"9'-11"10'-0"10'-0"14'-4"5'-0"16'-8"

5'-0"

5'-0"

10'-10"

12'-0"

7'-4" 9'-8" 13'-4"

18'-0" 5'-0" 12'-0"

14'-6"

10'-0"

10'-10" 6'-6" 12'-10"

25'-10"5'-0"

14'-4"

7'-4" 10'-6" 5'-0"

23'-4"10'-0"

STAFF

LOUNGE/TEAM

CONFERENCE

ROOM

36" OPENING

FOR REFRIG

ICE MAKER

CONNECTION

W3030

B30SB36

W3615

NCO

OFFICE

(SHARED)

WORKSTATION

WORKSTATION

STORAGE

SHELVING

/2

/2

OFFICE

COMMANDER

ADMIN

OFFICE

MED

RECORDS

WORKSTATION

WORKSTATION

CONSULT

OFFICE

PERSONAL

PROPERTY

LOCKERS

TREATMENT

AREA/TRACTION

EXERCISE

AREA

PATIENT

TOILET

"G .B

36"G.B.

18"V.G.B.

TREATMENT

CUBICLE

TREATMENT

CUBICLE

STAFF

TOILET JANITOR'S

CLOSET

MOP

SINK

30 GAL

W/H

STAFF

LOUNGE /

CONFERENCE

ROOM

NCOIC

OFFICE

WAITING

RECEPTION

COPY/FILE

DISTRO

OFFICE

EXAM

ROOM

COMM

ROOM

OFFICE

EXAM

ROOM

APPOINTMENT

CLEARKS

SHIPPING/

RECEIVING

TECHNICAL

SUPERVISOR

SHARED

NCOIC

OFFICE

OIC

OFFICE

CENTRAL

STORAGE

M/TLT

MICRO

BIOLOGY

JANITOR

MOP

SINK

30 GAL

W/H

F/TLT

SPECIMEN

TOILET

WAITING

RECEPTION

COPY/FILE

DISTRO

TECH

TECH

BLOOD

DRAW AREA

CORE

LAB

STAFF

LOUNGE/TEAM

CONFERENCE

ROOM

SIMULATION

CLASSROOM

CHIEF

ED&T

OFFICE

MDG

COMPUTER

CLASSROOM

MAIN

CLASSROOM

/0 x5 /0

V S

/0 x5 /0

V S

/0 x5 /0

V S

2/0x5/0VS

2/0x5/0VS

2/0x5/0VS

2/0x5/0VS

11" 3'-4"

4" 4" 4" 4" 4" 4"

6"

/2

11'-2"6"

LINE PLENUM WALL WITH

MIN. 1/2" GYPSUM, TYP.

LINE PLENUM WALL WITH

MIN. 1/2" GYPSUM, TYP.

B

PANEL "A"

150 AMP

120/208v, 1Ø

B

F

/8

PANEL "B"

150 AMP

120/208v, 1Ø

PANEL "C"

150 AMP

120/208v, 1Ø

PANEL "D"

150 AMP

120/208v, 1Ø

PANEL "E"

150 AMP

120/208v, 1Ø

PANEL "F"

150 AMP

120/208v, 1Ø

PANEL "G"

150 AMP

120/208v, 1Ø

PANEL "H"

150 AMP

120/208v, 1Ø

PANEL "i"

150 AMP

120/208v, 1Ø

PANEL "J"

150 AMP

120/208v, 1Ø

PANEL "K"

150 AMP

120/208v, 1Ø PANEL "L"

150 AMP

120/208v, 1Ø

PANEL "M"

150 AMP

120/208v, 1Ø

PANEL "N"

150 AMP

120/208v, 1Ø

PANEL "o"

150 AMP

120/208v, 1Ø

PANEL "P"

150 AMP

120/208v, 1Ø

5'-3"

5'-3

1'-5 3/4"

5'-7 1/8"

5'-7 1/8"

1'-5

/4

/2

/2

/8

7'-7 1/8"

B B

B

F

D

HK

A

E

EB

C

C

C

C

C C C

DD

C

C

CC

C

C

C

C

D

C

C

C

C

C

D

C G

C

C

C

8'-4"

H

3'-0"

11'-4"

F.D.

w/T.P.

1 1/2"VTR

3"VTR

3"VTR

P

LU

M B

W A

LL

F.D.

w/T.P.

B

B

B

D

D

B

7'-10"

2'-6"

3'-4" 7'-0"

3'-4"

3'-0"

C

F

B

C

B

B B

5'-2"

F

H J

1'-0"

F F

F

B

F

EXERCISE

AREA

F

B B

6'-0"8'-6"

6'-0"8'-6"

B

B

B

B

H

B

B

6'-0"8'-6"

6'-0"8'-6"

1'-7"

4" 4"

B

B

B

2"B.V.

P

LU

M B

W A

LL

1'-0"

H H H HB B B

F.D.

w/T.P.

D

D

D

D

5'-8"

D

D

D

D

D D

D

B

B

B

B

B

B

B

B

B

B

B

B B

D

F.D.

w/T.P.

D

5'-4"3'-2"4'-6"

8'-8"1'-0"10'-0"

F

B-102

82.50 SF

V.C.T.

B-104

343.75 SF

V.C.T.

B-101

94.50 SF

CARPET

S-106

129.88 SF

CARPET

S-105

129.88 SF

CARPET

S-103

64.18 SF

V.C.T.

S-101d

82.50 SF

V.C.T.

S-101a

80.62 SF

V.C.T.

S-104

64.18 SF

V.C.T.

S-102

126.67 SF

CARPET

V.C.T.

V.C.T.

V.C.T.

V.C.T.

G-109a

63.89 SF

V.R.G.

G-109b

46.67 SF

V.R.G.

G-103a

178.33 SF

V.C.T.

A-107

61.83 SF

V.R.G.

G-108

35.00 SF

V.R.G.

A-106

114.67 SF

V.C.T.

G-107

80.00 SF

CARPET

G-106

80.00 SF

CARPET

G-102

80.00 SF

V.C.T.

G-101

153.75 SF

V.C.T.

G-103

565.76 SF

V.C.T.

G-103

556.28 SF

V.C.T.

G-103c

175.67 SF

V.C.T.

A-101

145.00 SF

CARPET

A-102

145.00 SF

V.C.T.

G-105

166.75 SF

V.C.T.

G-104

166.75 SF

V.C.T.

A-105

170.00 SF

V.C.T.

A-104

60.00 SF

V.R.G.

A-103

170.00 SF

V.C.T.

K-107

164.33 SF

V.C.T.

K-103

314.33 SF

V.C.T.

K-104

108.00 SF

V.C.T.

K-104a

108.00 SF

V.C.T.

K-101

279.00 SF

V.C.T.

K-102

52.50 SF

V.R.G.

K-108

225.50 SF

V.C.T.

K-109

102.00 SF

CARPET

K-111

106.72 SF

CARPETK-112

151.67 SF

V.C.T.

P-106

520.67 SF

CARPET

113.34 SF

CARPET

K-105a

106.67 SF

V.C.T.

K-105

735.00 SF

V.C.T.

P-101

195.00 SF

V.C.T.

A-108

281.64 SF

V.C.T.

V.C.T.

V.C.T.

V.C.T.

V.C.T.

P-102

98.82 SF

CARPET

P-103

140.83 SF

CARPET

V.C.T.

V.C.T.

V.C.T.

A

EXIT B

W.P.

w/P.C.

EXIT B

W.P.

w/P.C.

EXIT B

EXIT BEXIT BEXIT BEXIT B

W.P.

w/P.C.

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

15'-8"

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

60"x12"(D) LAMINATED

COUNTER AT 34" A.F.F.

60"x12"(D) LAMINATED

COUNTER AT 34" A.F.F.

FLOORS:

NOTE: FLOOR JOISTS IN

UNITS "G & H" FROM 32'-0"

TO 40'-0" TO BE 12" O.C.

EXIT B

EXIT B

EXIT B

(2) 2" CONDUITS

UP THRU FLOOR

I/D UNIT

O/D UNIT

2"VTR

1 1/2"A.V.

/0 x6 /8

42"G.B.

"G .B

"V .G

.B

STAFF

TOILET

D6

P

LU

M B

W A

LL

2"VTR

F.D.

w/T.P.

B-103

61.83 SF

V.R.G.

/0 x6

/8

F

3/0x6/8

C

ON-CALL

ROOM

B-105

66.00 SF

V.C.T.

8'-10"

/0 x6 /8

C

KITCHEN

B-104a

S-101c

S-101b

G-103b

G-102a

42"G.B.

"G .B

"V .G

.B

"24"

DOOR

"24"

DOOR

2"B.V.

F.D.

w/T.P.

3"VTR

36"

DOOR

P

LU

M B

W A

LL

42"G.B.

"G .B

"V .G

.B

2"B.V.

F.D.

w/T.P.

3"VTR

36"

DOOR

K-105b

42"G.B.

"G .B

"V .G

.B

MOP

SINK

STAFF

TOILET

"V

T R

F.D.

w/T.P.

1 1/2"VTR

JANITOR

A-106

38.50 SF

V.R.G.

K-106

30.00 SF

V.R.G.

F.D.

w/T.P.

H

3/0x6/8

C

P

LU

M B

W A

LL

/0 x6 /8

C

SITE INSTALLED CORRIDORSITE INSTALLED CORRIDORSITE INSTALLED CORRIDORSITE INSTALLED CORRIDOR

/2 "V

T R

/0 x6 /8

C

A A1.0

B A1.0

D A1.0 A1.0

3/0x6/8

/0 x6 /8

D

6'-4"2'-6"

9'-10"

4'-7"

P

LU

M B

W A

LL

5'-0"

/0 x6 /8 C

STORAGE

P-105

75.83 SF

V.C.T.

3/0x6/8

C

TECH

OFFICE

A-646

110.00 SF

CARPET

C

D

3/0x6/8

C

C

8'-8"

CRUTCH

SPLINT/STO

G-107

118.08 SF

V.C.T.

OIC

OFFICE

"G .B

36"G.B.

18"V.G.B.

F.D.

w/T.P.

PATIENT

TOILET

3"VTR

1 1/2"VTR

27'-0"

28'-10"

12'-0" 6

B

/0 x6 /8

C

DN

DN

B

B

B

36" OPENING

FOR REFRIG

ICE MAKER

CONNECTION

W3030

B30 SB36

W3615 W1830

B18

1 1/2"VTR

30 GAL

W/H

ACCESS

36"x48"

3/0x6/8

C

5'-7" 4'-0" 2'-1"

NON-STRUCT

HEADER; SITE

INSTALL DOOR

7'-4"

M

IN

3'-2"

3'-10" 4'-11" 4'-11"

3'-4"

3/0x6/8

17'-0"

11'-8"

B

6'-6"

ACCESS

36"x48"

5'-0"4'-8"

/0 x6 /8

10'-0"

G

SB36B36

1 1/2"VTR

SB30

1 1/2"A.V.

WALL MOUNTED

BABY CHANING

STATION, TYP. of (2)

2'-6"

2'-10"

13'-0"

2"VTR

F.D.

w/T.P.

2"B.V.

2"B.V.

24"(D) LAMINATED

COUNTER TOP @

30" A.F.F.

24"(D) LAMINATED

COUNTER TOP @

30" A.F.F.

1 1/2"VTR

EYEWASH

STATION TO BE

ADDED TO SINK

B

D

CANOPY

NOTE: DO NOT INSTALL

REMOTE HEADS IN CORRIDOR

INSTALL PLATES, TYP.

SEE TCCA2.0 FOR

ADDITIONAL DETAILS

SEE TCCA2.0 FOR

ADDITIONAL DETAILS

NOTE: DO NOT INSTALL

REMOTE HEADS IN CORRIDOR

INSTALL PLATES, TYP.

C

5'-0"

3/0x6/8

C

ON-CALL

ROOM

B-106

66.00 SF

V.C.T.

8'-10"

C

TSA2.1

B

TSA2.1

A

TSA2.1

D

TSA2.1

E

TSA2.1

E

TSA2.1

E

TSA2.1

F

TSA2.1

H

TSA2.1

G

TSA2.1

J

TSA2.1

K

TSA2.1

M

TSA2.1

L

TSA2.1

N

TSA2.1

P

TSA2.1

E

TSA2.1

Q

TSA2.1

R

TSA2.1

DN

3'-0"

S

IN

K

SINK S

IN

K

1 1/2"ISLAND

VENT

2"VTR

5'-0"

NOTE: CORE LAB FLOOR DEFLECTION

"L/240" TO BE LESS THAN 1/8 INCH

M

IN

/2 "V

T R

M

IN

18"

MIN.

10"

B U

LK

H

E A

D

B U

LK

H

E A

D

BULKHEAD

B U

LK

H

E A

D

B U

LK

H

E A

D

B U

LK

H

E A

D

STAINLESS STEEL

WALL MOUNTED

HAND SINK

5'-1"

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 850 CFM @ .4 IWC ESP

w/DEHUMIDIFIER AND C.R.V. (50%

FRESH AIR INTAKE); 208v 1Ø; w/2

INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED PER

MFG'R SPEC'S w/7.5 kW HEAT STRIP;

1000 CFM @ .4 IWC ESP w/25% FRESH AIR INTAKE AND DEHUMIDIFIER ; 208v

1Ø; w/2 INCH MERV-8 PLEATED FILTER

3.0 TON WALL HUNG HVAC UNIT

(MD#:W36A2-A10XP) INSTALLED PER

MFG'R SPEC'S w/7.5 kW HEAT STRIP; 1000

CFM @ .4 IWC ESP w/DEHUMIDIFIER AND

C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

3.0 TON WALL HUNG HVAC UNIT

(MD#:W36A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 1000 CFM @ .4 IWC ESP

w/25% FRESH AIR INTAKE; 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED PER

MFG'R SPEC'S w/7.5 kW HEAT STRIP; 850

CFM @ .4 IWC ESP w/DEHUMIDIFIER AND

C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

3.0 TON WALL HUNG HVAC UNIT

(MD#:W36A2-A10XP) INSTALLED PER

MFG'R SPEC'S w/7.5 kW HEAT STRIP; 1000

CFM @ .4 IWC ESP w/DEHUMIDIFIER AND

C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

3.5 TON WALL HUNG HVAC UNIT

(MD#:W42A2-A10XP) INSTALLED PER

MFG'R SPEC'S w/7.5 kW HEAT STRIP; 1200

CFM @ .4 IWC ESP w/DEHUMIDIFIER AND

C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT (MD#:W30A2-A10XP)

INSTALLED PER MFG'R SPEC'S w/7.5 kW HEAT STRIP;

850 CFM @ .4 IWC ESP w/25% FRESH AIR INTAKE; 208v

1Ø; w/2 INCH MERV-8 PLEATED FILTER

3.0 TON WALL HUNG HVAC UNIT (MD#:W36A2-A10XP)

INSTALLED PER MFG'R SPEC'S w/7.5 kW HEAT STRIP;

1000 CFM @ .4 IWC ESP w/25% FRESH AIR INTAKE;

208v 1Ø; w/2 INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED PER

MFG'R SPEC'S w/7.5 kW HEAT STRIP;

1000 CFM @ .4 IWC ESP w/25% FRESH AIR INTAKE AND DEHUMIDIFIER ; 208v

1Ø; w/2 INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED PER

MFG'R SPEC'S w/7.5 kW HEAT STRIP;

850 CFM @ .4 IWC ESP w/25% FRESH

AIR INTAKE; 208v 1Ø; w/2 INCH

MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED PER

MFG'R SPEC'S w/7.5 kW HEAT STRIP; 850

CFM @ .4 IWC ESP w/DEHUMIDIFIER AND

C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED PER

MFG'R SPEC'S w/7.5 kW HEAT STRIP;

850 CFM @ .4 IWC ESP w/25% FRESH

AIR INTAKE; 208v 1Ø; w/2 INCH

MERV-8 PLEATED FILTER

3.0 TON WALL HUNG HVAC UNIT

(MD#:W36A2-A10XP) INSTALLED PER

MFG'R SPEC'S w/7.5 kW HEAT STRIP; 1000

CFM @ .4 IWC ESP w/DEHUMIDIFIER AND

C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

3.0 TON WALL HUNG HVAC UNIT

(MD#:W36A2-A10XP) INSTALLED PER

MFG'R SPEC'S w/7.5 kW HEAT STRIP; 1000

CFM @ .4 IWC ESP w/DEHUMIDIFIER AND

C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

3.0 TON WALL HUNG HVAC UNIT

(MD#:W36A2-A10XP) INSTALLED PER

MFG'R SPEC'S w/7.5 kW HEAT STRIP; 1000

CFM @ .4 IWC ESP w/DEHUMIDIFIER AND

C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

/0 x6 /8

C

F.D.

w/T.P.

EMERGENCY DRENCH

SHOWER/EYEWASH STATION

tim.kitchens Snapshot

1273939250A Accepted

1273939250A Accepted

1273939250A Accepted

1273939250A Accepted

1273939250A Accepted

1273939250A Accepted

1273939250A Accepted

File details come from the government source that posted it.