NOTE:
THIS IS A MASTER SYMBOLS LIST. ALL SYMBOLS, ABBREVIATIONS, ETC.
MAY NOT NECESSARILY BE USED ON ALL DRAWINGS.
ONE LINE AND RISER
MISCELLANEOUS
STANDARD MOUNTING HEIGHTS U.N.O.
ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER MOUNTING
HEIGHTS INDICATED ON ELECTRICAL DRAWINGS.
RECEPTACLES (CENTERLINE) NEW CONSTRUCTION 18"
RECEPTACLES IN EQUIP. RMS. 48"
RECEPTACLES (EXTERIOR) 24"
RECEPTACLES (GARAGES) 24"
ALARMS, SWITCHES AND CONTROLS (CENTERLINE) 48"
SAFETY SWITCHES 48"
STARTERS 48"
PANELS (TOP) 72"
CLOCK OUTLETS (CENTERLINE) 84"
REMOTE INDICATING LIGHT (EQUIP. RMS.) 48"
REMOTE INDICATING LIGHT (FIN. AREAS) CEILING
EXIT SIGNS (WALL MOUNTED BTM.) 80"
TELEVISION OUTLETS 18" BELOW CEILING U.N.O. ON PLAN
PHOTOCELLS 12'-0"
JUNCTION BOXES 18"
POWER LIGHTING MISCELLANEOUS ABBREVIATIONS ELECTRICAL GENERAL NOTES
CURRENT TRANSFORMER, RATED AS SPECIFIED OR
REQUIRED
MOTOR
SURGE PROTECTIVE DEVICE
GROUND CONNECTION
SWITCH, RATING AS SHOWN
FUSE, FUSE AMPACITY AND TYPE AS SHOWN
CIRCUIT BREAKER, RATING AS SHOWN
UTILITY METER (AS REQUIRED BY UTILITY)
SAFETY SWITCH, FUSED
SAFETY SWITCH, NON-FUSED
COMBINATION STARTER (SIZE AS INDICATED)
TRANSFORMER, TYPE AND RATING AS SHOWN
CONDUIT CONNECTION
CIRCUIT BREAKER WITH GROUND FAULT PROTECTION
GROUND CONNECTION WITH TEST WELL
GROUND ROD
DRAW OUT CIRCUIT BREAKER, RATINGS AS SHOWN, 3
POLE U.N.O.
FEEDER TAG - REFER TO FEEDER SCHEDULE
ELECTRONIC METER
GROUND FAULT RELAY
ENCLOSED CIRCUIT BREAKER, RATING AS INDICATED.
KEY NOTE DESIGNATION
SHORT CIRCUIT TAG DESIGNATION
EQUIPMENT CONNECTION TAG DESIGNATION
REVISION NUMBER DESIGNATION
NEW TO EXISTING CONNECTION
EXISTING CONDITIONS
DEMOLITION WORK
PANELBOARD, ELECTRICAL DISTRIBUTION PANEL, OR LOAD CENTER. SURFACE
MOUNTED. NEC CLEARANCE IS DENOTED BY DASHED LINES.
PANELBOARD, ELECTRICAL DISTRIBUTION PANEL, OR LOAD CENTER. FLUSH
MOUNTED. NEC CLEARANCE IS DENOTED BY DASHED LINES.
20 AMP, 125V, NEMA 5-20R DUPLEX RECEPTACLE. G = GFCI, T = TAMPER
PROOF, D = DATA POWER (NAMEPLATE LABELED "DATA POWER"), TV =
TELEVISION POWER, WP/G = WEATHER PROOF GFCI, H = HOSPITAL GRADE
(NOTE: SUBSCRIPTS ARE TYPICAL FOR ALL RECEPTACLE SYMBOLS)
20 AMP, 125V, NEMA 5-20R DUPLEX RECEPTACLE, MOUNTED 6" ON CENTER
ABOVE COUNTER AND/OR ABOVE BACKSPLASH BUT NOT MORE THAN 48" AFF
TO TOP OF RECEPTACLE COVER PLATE.
20 AMP, 125V, NEMA 5-20R QUAD RECEPTACLE
20 AMP, 125V, 2P, 3W DUPLEX RECEPTACLE, CONNECTED TO EMERGENCY
POWER, SHALL BE HOSPITAL GRADE, RED IN COLOR.
20 AMP, 125V, 2P, 3W QUADPLEX RECEPTACLE, CONNECTED TO EMERGENCY
POWER, SHALL BE HOSPITAL GRADE, RED IN COLOR.
20 AMP, 125V, NEMA 5-20R DUPLEX FLOOR RECEPTACLE, 3/4" CONDUIT RUN
CONCEALED IN FLOOR SLAB.
20 AMP, 125V, NEMA 5-20R QUAD FLOOR RECEPTACLE, 3/4" CONDUIT RUN
CONCEALED IN FLOOR SLAB.
20 AMP, 125V, NEMA 5-20R QUAD FLOOR RECEPTACLE, 3/4" CONDUIT RUN
CONCEALED IN FLOOR SLAB CONNECTED TO EMERGENCY POWER.
20 AMP, 125V, NEMA 5-20R CEILING MOUNTED DUPLEX RECEPTACLE
CEILING MOUNTED JUNCTION BOX
FLOOR MOUNTED JUNCTION BOX
JUNCTION BOX, WALL MOUNTED
ELECTRICAL CONNECTION POINT
SPECIAL RECEPTACLES, CONFIGURATION AS NOTED ON PLAN
SPECIAL RECEPTACLES, WALL MOUNTED, CONFIGURATION AS NOTED ON PLAN
SPECIAL RECEPTACLES, WALL MOUNTED, CONNECTED TO EMERGENCY
POWER, CONFIGURATION AS NOTED ON PLAN
MOTOR: HORSEPOWER AS INDICATED ON PLANS OR DIAGRAMS
PLUGMOLD, REFER TO DRAWING FOR LENGTHS, 20A DUPLEX RECEPTACLES
SPACE 18" ON CENTER U.N.O.
SAFETY SWITCH, NON-FUSED, 240V, U.N.O.
COMBINATION STARTER (SIZE AS INDICATED)
SINGLE POLE SWITCH; LOWER CASE LETTER INDICATES LUMINAIRES
CONTROLLED, 3= THREE WAY SWITCH, 4= FOUR WAY SWITCH, K= KEY SWITCH,
D= DIMMER SWITCH, P= PILOT LIGHT, D3= THREE WAY DIMMER SWITCH, 2OS=
DUAL RELAY OCCUPANCY SENSING SWITCH, SC= SCENE SWITCH, OS= SINGLE
RELAY OCCUPANCY SENSOR, LV= LOW VOLTAGE SWITCH, VS= VACANCY
SENSOR, M= MOTOR RATED SWITCH.
VARIABLE FREQUENCY DRIVE.
GROUNDING BUS BAR.
PUSH PAD FOR ASSISTED DOOR.
X
X
X
J
J
A AMPS, AIR (COMPRESSED)
AC ABOVE COUNTER
AFC ABOVE FINISHED CEILING
AFEA AREA FOR EVACUATION
ASSISTANCE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
AIC AMPERE INTERRUPTING CURRENT
AL ALUMINUM
ATS AUTOMATIC TRANSFER SWITCH
AWG AMERICAN WIRE GAUGE
AV FOR AUDIO VISUAL MEDIA
CABINET
BFF BELOW FINISHED FLOOR
BKR BREAKER
BOS BOTTOM OF STRUCTURE
BTU BRITISH THERMAL UNIT
C CONDUIT
CATV CABLE TELEVISION SYSTEM
CCTV CLOSED CIRCUIT TELEVISION
CFM CUBIC FEET PER MINUTE
CKT CIRCUIT
CLG CEILING
CM COFFEE MAKER
CU COPPER, CONDENSING UNIT
DDC DIRECT DIGITAL CONTROL
DN DOWN
DPDT DOUBLE POLE, DOUBLE THROW
DPST DOUBLE POLE, SINGLE THROW
DW DISHWASHER
DX DIRECT EXPANSION
(E) EXISTING
ECB ENCLOSED CIRCUIT BREAKER
EPO EMERGENCY POWER OFF
ETR EXISTING TO REMAIN
FACP FIRE ALARM CONTROL PANEL
FBO FURNISHED BY OTHERS
FF FINISHED FLOOR
FHC FIRE HOSE CABINET
FLA FULL LOAD AMPS
FLR FLOOR
FOPP FIBER OPTIC PATCH PANEL
FVNR FULL VOLTAGE, NON REVERSING
GD GARBAGE DISPOSAL
GFI GROUND FAULT CIRCUIT
INTERRUPTER (PERSONAL
PROTECTION ON DEVICE)
GFCI GROUND FAULT CIRCUIT
INTERRUPTER (PERSONAL
PROTECTION ON DEVICE)
GFP GROUND FAULT PROTECTED
FROM UPSTREAM
GFR GROUND FAULT RELAY
GND GROUND
HOA HAND OFF AUTOMATIC
HPS HIGH PRESSURE SODIUM
HSTAT HUMIDISTAT
HTG HEATING
HTR HEATER
IG ISOLATED GROUND
KCMIL 1000 CIRCULAR MILS
KV KILOVOLT
KVA KILOVOLT AMPS
KVAR KILOVOLT AMPS REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
LF LINEAR FEET
LIU LIGHT GUIDE INTERFACE UNIT
(FOPP)
LRA LOCKED ROTOR AMPS
1. FINAL CONNECTIONS TO EQUIPMENT MUST BE IN ACCORDANCE WITH
MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS.
2. WIRE TERMINATION PROVISIONS FOR PANEL BOARDS, CIRCUIT BREAKERS, SAFETY
SWITCHES, AND ALL OTHER ELECTRICAL EQUIPMENT AND DEVICES MUST BE LISTED
AS SUITABLE FOR 75°C MINIMUM.
3. SYSTEMS MUST BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS
DEFECTIVE, CONTRACTOR MUST MAKE CORRECTIONS NECESSARY.
4. THE COMPLETED INSTALLATION MUST BE IN ACCORDANCE WITH ALL ENGINEERING
REQUIREMENTS, THE GOVERNMENTS DESIGN CRITERIA, UTILITY COMPANY
REQUIREMENTS, APPLICABLE INDUSTRY STANDARDS OF GOOD PRACTICE AND
SAFETY AND THE MANUFACTURER'S RECOMMENDATIONS FOR EQUIPMENT AND
PRODUCT APPLICATION AND INSTALLATION.
5. THE DATA GIVEN ON THE DRAWING IS AS EXACT AS COULD BE SECURED. THE
CONTRACTOR MUST OBTAIN EXACT LOCATION, MEASUREMENTS, LEVELS, ETC. AT THE
SITE AND SHALL SATISFACTORILY ADAPT THE WORK TO THE ACTUAL CONDITIONS AT
THE BUILDING.
6. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND
IN FIELD PRIOR TO COMMENCEMENT OF WORK.
7. THIS CONTRACTOR MUST MAINTAIN ACCURATE RECORDS OF ANY MODIFICATIONS
AND MUST UPON COMPLETION, DELIVER ALL "RECORD" DRAWINGS TO THE
GOVERNMENT INDICATING SUCH CHANGES. CONTRACTOR MUST MAINTAIN IN THE
PROJECT CONSTRUCTION OFFICE UP-TO-DATE, NEATLY MARKED COPY OF THESE
DRAWINGS FOR REVIEW BY THE ARCHITECT, ENGINEERING, OR GOVERNMENT'S
REPRESENTATIVE.
8. ALL ELECTRICAL SYSTEMS COMPONENTS MUST BE LISTED OR LABELED BY UL OR
OTHER RECOGNIZED TESTING FACILITY AS A MINIMUM.
9. COORDINATE THE INSTALLATION OF DEVICES WITH ALL OTHER TRADES.
10. ROUTE ALL WIRE AND CONDUIT CONCEALED UNLESS OTHERWISE NOTED.
11. COORDINATE EXACT MOUNTING HEIGHT OF ALL DEVICES WITH ARCHITECTURAL
PLANS AND ELEVATIONS. WHERE GANGED COVERPLATES ARE REQUIRED, THESE
WILL BE CUSTOM MANUFACTURED IN A SINGULAR UNIT.
12. CONTRACTOR MUST COORDINATE ALL WALL SURFACES, FURRING & FINISHES WITH
ARCHITECTURAL PLANS. ALL WIRING DEVICES SHOWN ON THIS PLAN MUST BE FLUSH
MOUNTED, UNO.
13. ELECTRICAL INSTALLATION WITHIN THE PLENUM CEILING SPACES MUST BE IN
ACCORDANCE WITH THE REQUIREMENTS OF THE NEC, SECTION 300.22(C).
14. MAIN SERVICE EQUIPMENT GROUNDING ELECTRODE SYSTEM MUST HAVE A
RESISTANCE OF 5 OHMS OR LESS IN ACCORDANCE WITH THE REQUIREMENTS OF THE
NEC, SECTION 250.66 AND INTERIOR DISTRIBUTION SYSTEM 26 20 00, WHICHEVER IS
MORE RESTRICTIVE.
15. CONDUITS SHALL NOT RUN DIRECTLY BELOW ROOF DECKING ON TOP OF
STRUCTURAL MEMBERS. TOP OF CONDUITS TO MAINTAIN 6" CLEARANCE FROM
LOWER SURFACE OF ROOF DECKING.
16. ALL CIRCUITS INCLUDING SINGLE PHASE 120V OR 277V CIRCUITS MUST CONTAIN A
DEDICATED NEUTRAL CONDUCTOR AND A GREEN INSULATED EQUIPMENT GROUND
CONDUCTOR.
17. REFERENCE S0.01 FOR SEISMIC REQUIREMENTS.
18. PROVIDE PULL STRINGS FOR ALL EMPTY CONDUITS.
NOTES: UPPER CASE LETTER DENOTES LUMINAIRES TYPE. LOWER CASE LETTER ADJACENT TO
LUMINAIRE INDICATES SWITCH THAT CONTROLS LUMINAIRES
A
2' X 4' RECESSED LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE.
2' X 4' RECESSED LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE. SHADING
DENOTES FIXTURE WITH BATTERY BACK UP, UNLESS OTHERWISE NOTED.
PENDANT LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE. HATCHING
DENOTES FIXTURE WITH BATTERY BACK UP, UNLESS OTHERWISE NOTED.
RECESSED MOUNTED DOWNLIGHT, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE. HALF-
SHADING DENOTES FIXTURE WITH BATTERY BACK UP, UNLESS OTHERWISE NOTED.
WALL MOUNTED LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE. HALF-
SHADING DENOTES FIXTURE WITH BATTERY BACK UP, UNLESS OTHERWISE NOTED.
WALL WASH LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE. HALF-SHADING
DENOTES FIXTURE WITH BATTERY BACK UP, UNLESS OTHERWISE NOTED.
CEILING MOUNTED EXIT SIGN. PROVIDE DIRECTIONAL ARROWS AS REQUIRED. SHADED
PORTION CORRESPONDS TO ILLUMINATED FACE.
WALL MOUNTED EXIT SIGN. PROVIDE DIRECTIONAL ARROWS AS REQUIRED. SHADED
PORTION CORRESPONDS TO ILLUMINATED FACE.
SINGLE POLE MOUNTED, EXTERIOR LUMINAIRE
DOUBLE POLE MOUNTED, EXTERIOR LUMINAIRE
BOLLARD LUMINAIRE
SINGLE POLE SWITCH; LOWER CASE LETTER INDICATES LUMINAIRES CONTROLLED, 3 =
THREE WAY SWITCH, 4 = FOUR WAY SWITCH, K = KEY SWITCH, D = DIMMER SWITCH, P =
PILOT LIGHT, D3 = THREE WAY DIMMER SWITCH, 2OS = DUAL RELAY OCCUPANCY SENSING
SWITCH, SC = SCENE SWITCH, OS = SINGLE RELAY OCCUPANCY SENSOR, LV = LOW
VOLTAGE SWITCH
CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR WITH ISOLATED RELAY, "P" =
ONLY PASSIVE INFRARED TYPE
STRIP INDUSTRIAL TYPE LIGHT FIXTURE, LETTER DENOTES FIXTURE TYPE, MOUNTING IS
NOTED ON FIXTURE SCHEDULE
DUAL RELAY OCCUPANCY SENSING SWITCH
OS
1. INFORMATION REGARDING THE EXISTING ELECTRICAL SYSTEMS TO BE DEMOLISHED IS
BASED ON AS-BUILT DRAWINGS/OPERATOR KNOWLEDGE FROM THE CONTRACTING
OFFICE AND SITE OBSERVATIONS. INFORMATION PROVIDED IS AS EXACT AS COULD BE
SECURED. DEMOLITION WORK SHALL BE SATISFACTORILY ADAPTED TO THE ACTUAL SITE
CONDITIONS AND AS REQUIRED FOR FINAL PROJECT REQUIREMENTS. UNFORESEEN
EXISTING CONDITIONS EFFECTING THIS SCOPE MUST BE BROUGHT TO GOVERNMENT'S
ATTENTION AS SOON AS THEY ARE DISCOVERED.
2. PROVIDE ALL NECESSARY DEMOLITION TO REMOVE EXISTING CONDUIT, WIRE, CABLE, J-
BOXES, RECEPTACLES, SWITCHES, LIGHTS, ETC. COMPLETE WITH ASSOCIATED WIRING
TO SOURCE. WHERE IT IS NOT FEASIBLE TO REMOVE THE ABOVE, OUTLETS MAY BE
ABANDONED, WIRE REMOVED, AND BLANK COVER PLATES PROVIDED.
3. CONDUIT EMBEDDED IN WALLS TO REMAIN MAY BE ABANDONED IN PLACE. EXISTING
BOXES MAY REMAIN IF FINISHED SURFACE MATCHES SURROUNDING SURFACE.
4. NOT ALL WALLS OR CEILINGS OF CONSTRUCTION AREA ARE TO BE DEMOLISHED.
THEREFORE COORDINATE ALL ELECTRICAL DEMOLITION WORK WITH ARCHITECTURAL
PLANS AND GENERAL CONTRACTOR BEFORE DEMOLITION OF ALL DEVICES.
5. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF
DEMOLITION REQUIRED. CONTRACTOR MUST VISIT SITE TO DETERMINE EXTENT OF WORK
INVOLVED AND FIELD VERIFY EXISTING EQUIPMENT OR CIRCUITS THAT ARE REMAINING
TO BE RECONNECTED TO EXISTING SWITCHBOARDS/PANELBOARDS. PROVIDE LABOR,
AND FURNISH ALL MATERIALS, SWITCHES, RECEPTACLES, CONDUIT, WIRE, ETC. AS
REQUIRED TO MAINTAIN/RESTORE CONTINUITY OF SERVICE TO CIRCUIT(S).
6. PATCH ALL ABANDONED FLOOR PENETRATIONS PER ARCHITECTURAL SPECIFICATIONS.
PATCH ALL ABANDONED ROOF PENETRATIONS AS REQUIRED TO MAINTAIN EXISTING
ROOF WARRANTY.
7. THE CONTRACTOR MUST COORDINATE AND SCHEDULE ALL NECESSARY POWER OUTAGES
WITH THE CONTRACTING OFFICER'S REPRESENTATIVE PRIOR TO PROCEEDING WITH SUCH
WORK TO INSURE THAT OPERATIONS IN ADJACENT OCCUPIED PORTIONS OF THE
BUILDING ARE NOT INTERRUPTED OR RESTRICTED WITHOUT PRIOR APPROVAL. ALL WORK
SHALL BE COMPLETED IN DE-ENERGIZED ELECTRICAL SYSTEMS TO THE MAXIMUM
EXTENT POSSIBLE.
8. CONTRACTOR MUST REMOVE AND DISPOSE OF EXISTING ELECTRICAL EQUIPMENT IN
AREAS INDICATED ON THE PLANS UNLESS OTHERWISE NOTED. LEVELS OF RENOVATION
ARE DEFINED IN INDIVIDUAL DEMO SHEETS. DEMOLITION MUST INCLUDE THE FOLLOWING:
A. LIGHTING SYSTEM: ALL LIGHT FIXTURES AND EMERGENCY LIGHTING MUST BE
REMOVED.
B. POWER: CONDUIT, RACEWAYS, WIRING, DISCONNECTS, RECEPTACLES AND
CONNECTIONS TO EXISTING EQUIPMENT MUST BE REMOVED. REMOVE ALL
CONDUIT BACK TO SOURCE IF NOT TO BE REUSED.
C. PANELS: CONTRACTOR MUST USE CAUTION TO NOT DISTURB ANY "IN USE" OR
SALVAGEABLE BRANCH CIRCUITS, CONDUIT AND CIRCUIT BREAKERS. REUSE
AND/OR EXTEND ANY EXISTING CONDUIT AS NEEDED FOR USE WITH NEW
CONSTRUCTION.
D. DEVICES: WHEN DEMOLISHING DEVICES SHOWN IN WALL, DEMOLISH CONDUIT
AND WIRE BACK TO NEAREST J- BOX ABOVE ACCESSIBLE CEILING. REUSE
EXISTING CONDUIT AND WIRE TO THE GREATEST EXTENT POSSIBLE DURING NEW
ELECTRICAL INSTALLATION.
VFD
E
GENERAL DEMOLITION NOTES
TXX
THE E.C. SHALL UTILIZE THE CHART BELOW FOR WIRING BRANCH
CIRCUIT DEVICES AND MAINTAINING A MAXIMUM OF 3 PERCENT
VOLTAGE DROP IN ACCORDANCE WITH NEC AND USACE GUIDELINES.
20 AMP BRANCH CIRCUIT RUN
0' - 100' USE #12AWG COPPER
101' - 150' USE #10AWG COPPER
151' - 225' USE #8 TO FIRST J-BOX, #10 THEREAFTER.
VOLTAGE DROP REQUIREMENTS
MATV MASTER ANTENNA
TELEVISION SYSTEM
MBH 1000 BTU PER HOUR
MCA MINIMUM CIRCUIT
AMPACITY
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MD MOTORIZED DAMPER
MDP MAIN DISTRIBUTION PANEL
MFR MANUFACTURER
MG MOTOR GENERATOR
MH MANHOLE
MSB MAIN SWITCHBOARD
MTD MOUNTED
MW MICROWAVE
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
N/O,N/C NORMALLY OPEN,
NORMALLY CLOSED
NL NIGHT LIGHT
OC ON CENTER
OHE OVERHEAD PRIMARY
ELECTRICAL
OV OVEN
PDU POWER DISTRIBUTION
UNIT
PH, Ø PHASE
PIV POST INDICATOR VALVE
PJ MOUNTED ON CEILING
FOR PROJECTOR
PNL PANEL
PT POTENTIAL
TRANSFORMER
QTY QUANTITY
RA RETURN AIR
RCP REFLECTED CEILING PLAN
REF REFRIGERATOR
REV REVISION
RH RELATIVE HUMIDITY
RLA RUNNING LOAD AMPS
RPM REVOLUTIONS PER
MINUTE
SA SUPPLY AIR
SD SMOKE DETECTOR
SF SQUARE FEET
SPDT SINGLE POLE, DOUBLE
THROW
SPST SINGLE POLE, SINGLE
THROW
SP STATIC PRESSURE
SWBD SWITCHBOARD
TSTAT THERMOSTAT
TL TWISTLOCK
TV TELEVISION
TYP TYPICAL
U/F UNDER FLOOR
U/G UNDER GROUND
U/S UNDER SLAB
UGC UNDERGROUND
COMMUNICATION
UGP UNDERGROUND PRIMARY
ELECTRICAL
UGS UNDERGROUND
SECONDARY ELECTRICAL
UL UNDERWRITERS
LABORATORIES, INC.
UNO UNLESS NOTED
OTHERWISE
UPS UNINTERRUPTIBLE POWER
SUPPLY
VAC VOLTS ALTERNATING
CURRENT, VACUUM
VAV VARIABLE AIR VOLUME
VM VENDING MACHINE
W/ WITH
W/O WITHOUT
WP WEATHERPROOF
WT WATERTIGHT, WEIGHT
XFMR TRANSFORMER
XP EXPLOSION PROOF
BRANCH CIRCUITS HOMERUN USE MINIMUM NUMBER 12
AWG WIRE, UNLESS OTHERWISE NOTED. REFER TO
PANELBOARD DIRECTORY FOR CIRCUIT VOLTAGE.
PROVIDE 1 PHASE CONDUCTOR, 1 NEUTRAL CONDUCTOR
AND 1 GROUND CONDUCTOR UNLESS NOTED OTHERWISE.
CONDUIT AND WIRE CONCEALED, 1/2" UNLESS OTHERWISE
NOTED, CONDUIT USED FOR SWITCH LEGS, AND CONDUIT
USED FOR CONTROL WIRING. PROVIDE 1 PHASE
CONDUCTOR, 1 NEUTRAL CONDUCTOR AND 1 GROUND
CONDUCTOR MINIMUM UNLESS NOTED OTHERWISE.
CONDUIT AND WIRE EMBEDDED IN CONCRETE OR BELOW
GRADE
CONDUIT TURNING DOWN
CONDUIT TURNING UP
CONNECT TO CIRCUIT 1 IN PANEL NL2S1 (TYP.)
CONDUIT DESIGNATIONS
CONDUIT SIZE
WIRE SIZE
NUMBER OF WIRES
3 #10, 1 #12G, 3/4"C.
PM
GF
NL2S1-1
G
M
SPD
M
A
NEW CONSTRUCTION
AC
DEMOLITION WORK ON ONE-LINE
EXISTING ON ONE-LINE
NEW WORK ON ONE-LINE
J
PANEL
OS
LIGHTNING PROTECTION
LIGHTNING AIR TERMINAL
LIGHTNING PROTECTION GROUND ROD
LIGHTNING PROTECTION CONDUCTOR
PP
L
IT
T L
E R
O C
K D
IV
IS
IO
N
L
IT
T L
E R
O C
K
A R
K A
N S
A S
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A
54321
B
C
D
E
54321
B A
S E
C
IV
IL
E
N G
IN
E
E R
/D E
P U
T Y
C H
IE
F
E N
G
IN
E E
R
IN
G F
L
IG
H T
C
E P
C H
IE
F
C O
N T
R A
C T
S S
E C
T
IO
N
C E
P M
R E
C O
M M
E N
D E
D
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
R E
V D
A T
E E
N G
IN
E
E R
\D E
S
IG
N E
R
D R
A W
N B
Y
S C
A L
E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
C O
N T
R A
C T
N U
M B
E R
D E
S
IG
N T
E A
M
U S
IN
G
A G
E N
C Y
C H
E C
K E
D B
Y
H O
E F
E R
W Y
S O
C K
I
A R
C H
IT
E
C T
S
/3
/2
S U
B M
IT
T
A L
C
O R
R E
C T
E D
F
IN
A L
JE DUNN + HWA
NATIONAL HEALTHCARE DEISGN-BUILD TEAM
M .E
G
R O
U P
JE
D
U N
N
U S
A F
/2
/2
:2
:5
P
M
2"
'-0
C U s e rs
\a n d re w .b ri d g e s \D o c u m e n ts
\M E
G T y n d a ll_
A F
B M
E P a n d re w .b ri d g e s .r v t
S Y
M B
O L L
E G
E N
D A
N D
G E
N E
R A
L N
O T
E S
T Y
N D
A
LL
A F
B
E0.02
M A
G N
O
LI
A C
IR
C
LE
T Y
N D
A
LL
A F
B , F
L
A P
JV
W
5-
-R -6
W
5-
-D
-6
High Performance Building Consultants
Job #:
R m e UPG
601.042
S y m b o l
D es cr ip ti o n
T ra ck in g N o
A ct io n
D at e