05_1-CU1.02_UTILITY_PLAN_-_PHASE_2_AND_3.pdf
PDF 724 KB Posted
- Attached to
- Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
- Solicitation number
- W9127S19Q6039
About this file
Part of Attachment B1 - Additional Utility Plans
View the file
Other files for this federal contract opportunity
Show all 50
Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A B
A
A B
A A
B A
A B
A A
B A
A B
A
A
B
A
A
B
A
A
B
A
A
B
A
A
B
A
A
B
A
A
B
A
D
D
A B
A
A B
A
U T
I L
I T
Y
P
L A
N
P
H A
S E
N D
1-CU1.02
A1/CU5.01 JUNCTION BOX
A3/CU5.01 GRATE INLET
A5/CU5.01 NON-SETBACK CURB
INLET
D5/CU5.01 PIPE BEDDING
DETAILSDTL#
SHT
A1
CU5.01
A1
CU5.01
A5
CU5.01
A3
CU5.01
CONVERT CURB INLET
TO JUNCTION BOX
D5
CU5.01
D5
CU5.01
JUNCTION BOX
RIM = 19.80
FL W (18" RCP) = 14.17
FL N (15" RCP) = 14.42
FL E (18" RCP) = 14.17
INSTALL 16 LF OF 18"
RCP STORM LINE @ 0.6%
CONVERT CURB INLET
TO JUNCTION BOX
RIM = 18.90
FL W (18" RCP) = 14.04
FL NE (18" RCP) = 13.81
INSTALL 8 LF OF 15" RCP
STORM LINE @ 1.0%
INSTALL 4' X 4"CURB INLET
RIM = 18.70
FL S (15" RCP) = 14.50
1. ALL EXISTING UTILITIES HAVE
BEEN INDICATED TO THE
GREATEST EXTENT
AVAILABLE TO THE ENGINEER.
THE CONTRACTOR IS
RESPONSIBLE FOR
OBTAINING THE EXACT
LOCATION OF THE UTILITIES
PRIOR TO STARTING WORK.
2. WATER LINES SHALL BE
INSTALLED AT 30" MINIMUM
DEPTH.
3. ANY PAVEMENT REMOVED
DUE TO UTILITY TRENCHING
SHALL BE REPLACED TO
MATCH EXISTING. FOLLOW
APPLICABLE PAVEMENT
DETAILS AND
SPECIFICATIONS.
NOTES
UTILITY
PHASE 2
N
SCALE: 1" = 30'-0"
UTILITY
PHASE 3
N
SCALE: 1" = 30'-0"
INSTALL 36 LF OF
12" RCP @ 1%
INSTALL 4'x4' CURB INLET
RIM ELEV: 16.20'
FL: 11.71'
CONVERT TO 2'X2'
GRATE INLET
RIM ELEV: 18.63'
A1
CU5.01
A1
CU5.01
A5
CU5.01
LEGEND
= UNDER GROUND
COMMUNICATIONS
LINE
= FIBER OPTICS LINE
= OVERHEAD
ELECTRICAL LINE
= NATURAL GAS LINE
= WATER LINE
= FIRE PROTECTION
WATER SUPPLY
LINE
= SANITARY SEWER
LINE
= STORM DRAIN LINE
L I T
T L
E
R
O C
K
D
I V
I S
I O
N
L I T
T L
E
R
O C
K
A
R K
A N
S A
S
U S
A
R M
Y
C
O R
P
O
F
E
N G
I N
E E
R S
A
54321
B
C
D
E
54321
B A
C
I V
I L
E
N G
I N
E E
R D
E P
U T
Y
C H
I E
F
E
N G
I N
E E
R I N
G
F
L I G
H T
E P
C H
I E
F
C
O N
T R
A C
C
T I O
N
C
E P
M
R E
C O
M M
E N
D E
D
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
R E
V D
A T
E E
N G
I N
E E
R D
E S
I G
N E
R
D R
A W
N
B
Y
S C
A L E
S O
L I C
I T
A T
I O
N
N
U M
B E
R
C O
N T
R A
N
U M
B E
R D
E S
I G
N
T
E A
M J
U N
N
U S
I N
G
A
G E
N C
Y
C H
E C
K E
D
B
Y
H O
E F
R
W
Y S
O C
K I
A R
C H
I T
E C
T S
H O
W N
B H
C
R
H O
D E
S
M T
M C
J F
W R
W D
Sy mb ol De scr ipt ion Tr ac kin g N o.
Ac tio n Da te
F e b r u a r y v t y n d a l l a f b f y D
W G
E n g S h e e t M
C C o n s t r u c t i o n
D o c u m e n t s T
Y N
M C
U d w g
T Y
N D
A L
L
A
F B
M
A G
N O
L
R
C L
E
T
Y N
D A
L
B
F
L
M E
D I C
I N
I C
JE DUNN + HWA
NATIONAL HEALTHCARE DEISGN-BUILD TEAM
U S
A F
S U
B M
I T
T A
O R
R E
C T
N
File details come from the government source that posted it.