Text version
F U
L L B
U
IL
D
IN
G P
L A
N
TPF-
2.0
A
54321
B
C
D
E
B A
S E
C
IV
IL
E
N G
IN
E
E R
/D E
P U
T Y
C H
IE
F
E N
G
IN
E E
R
IN
G F
L
IG
H T
C
E P
C H
IE
F
C O
N T
R A
C T
S S
E C
T
IO
N
C E
P M
R E
C O
M M
E N
D E
D
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
R E
V D
A T
E E
N G
IN
E
E R
\D E
S
IG
N E
R
D R
A W
N B
Y
S C
A L E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
C O
N T
R A
C T
N U
M B
E R
D E
S
IG
N T
E A
M C
E P
M
U S
IN
G
A G
E N
C Y
C H
E C
K E
D B
Y
H O
E F
E R
W Y
S O
C K
I A
R C
H
IT
E C
T S
/3
/2
JE DUNN + HWA
CLEARWATER, FL 33756
CONSULTING ENGINEER
1765 CARNEGIE AVENUE
Ph: (727) 505-9941
JAMES E. BRADLEY, P.E.
J E B
0' 4' 8' 16' 32'
1/8" = 1'-0"
0' 2' 4' 8' 16'
1/4" = 1'-0"
0' 1' 2'
3/4" = 1'-0"
4'0' 1'
1 1/2" = 1'-0"
2' 2'1'6"6"3"0' 6"
3" = 1'-0"
1'3"
NOT FOR CONSTRUCTION
2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930
TPF TYNDALL -
CONNECTING CORRIDOR
T Y
N D
A L
L A
F B
C O
N N
E C
T
IN
G C
O R
R
ID
O R
M
A G
N O
L
IA
C
IR
C L
E T
Y N
D A
L L
A F
B
F L
A S
I N
D
IC
A T
E D
J .L
.B
W -1
-R
-6
W -1
-D
-6
J A
M E
S E
B
R A
D L E
Y P
.E
J E
D U
N N
S U
B M
IT
T
A L
C
O R
R E
C T
E D
F
IN
A L
J .E
.B
S y m b o l
D es cr ip ti o n
T ra ck in g N o
A ct io n
D at e
TPF TYNDALL - NORTH
PUBLIC HEALTH BLDG
TPF TYNDALL - SOUTH
AMBULANCE SERVICES BLDG
OVERALL FLOOR PLAN
SCALE: N.T.S.
CORRIDOR CORRIDOR
PANEL "B"
100 AMP
120/208v, 1Ø
PANEL "A"
100 AMP
120/208v, 1Ø
NOTE: DO NOT INSTALL
REMOTE HEADS IN CORRIDOR
INSTALL PLATES, TYP.
DN
DN
3.0 TON WALL HUNG
HVAC UNIT; TYP. of (16)
3/0x5/0VS
A B C D E F G H i J K L M N o P
4/0x6/8
3/0 x6
/8
3/0x6/8
3/0x6/8
3/0x6/8
3/0x6/8
/0 x6 /8
3/0x6/8
/0 x6 /8
3/0x6/8
/0 x6 /8
3/0x6/83/0x6/8
/0 x6 /8
/0 x6 /8
/0 x6 /8
/0 x6 /8
3/0x6/8
3/0x6/8
/0 x6 /8
3/0x6/8 3/0x6/8
/0 x6 /8
/0 x6 /8
3/0x6/8
/0 x6 /8
/0 x6 /8
/0 x6 /8
/0 x6 /8
/0 x6 /8
3/0x6/8 3/0x6/8
3/0x6/8
/0 x6 /8
/0 x6 /8
3/0x6/8
WORKSTATION
WORKSTATION
STORAGE
SHELVING
OFFICE
COMMANDER
ADMIN
OFFICE
MED
RECORDS
WORKSTATION
CONSULT
OFFICE
PERSONAL
PROPERTY
LOCKERS
TREATMENT
AREA/TRACTION
EXERCISE
AREA
PATIENT
TOILET
TREATMENT
CUBICLE
TREATMENT
CUBICLE
STAFF
TOILET JANITOR'S
CLOSET
30 GAL
W/H
STAFF
LOUNGE /
CONFERENCE
ROOM
NCOIC
OFFICE
WAITING
RECEPTION
COPY/FILE
DISTRO
OFFICE
EXAM
ROOM
COMM
ROOM
OFFICE
EXAM
ROOM
APPOINTMENT
CLEARKS
SHIPPING/
RECEIVING
TECHNICAL
SUPERVISOR
SHARED
NCOIC
OFFICE
OIC
OFFICE
CENTRAL
STORAGE
M/TLT
MICRO
BIOLOGY
JANITOR
30 GAL
W/H
F/TLT
SPECIMEN
TOILET
WAITING
RECEPTION
COPY/FILE
DISTRO
TECH
TECH
BLOOD
DRAW AREA
CORE
LAB
STAFF
LOUNGE/TEAM
CONFERENCE
ROOM
SIMULATION
CLASSROOM
CHIEF
ED&T
OFFICE
MDG
COMPUTER
CLASSROOM
MAIN
CLASSROOM
/0 x5 /0
V S
/0 x5 /0
V S
/0 x5 /0
V S
2/0x5/0VS
2/0x5/0VS
2/0x5/0VS
2/0x5/0VS
PANEL "A"
150 AMP
120/208v, 1Ø
PANEL "B"
150 AMP
120/208v, 1Ø
PANEL "C"
150 AMP
120/208v, 1Ø
PANEL "D"
150 AMP
120/208v, 1Ø
PANEL "E"
150 AMP
120/208v, 1Ø
PANEL "F"
150 AMP
120/208v, 1Ø
PANEL "G"
150 AMP
120/208v, 1Ø
PANEL "H"
150 AMP
120/208v, 1Ø
PANEL "i"
150 AMP
120/208v, 1Ø
PANEL "J"
150 AMP
120/208v, 1Ø
PANEL "K"
150 AMP
120/208v, 1Ø PANEL "L"
150 AMP
120/208v, 1Ø
PANEL "M"
150 AMP
120/208v, 1Ø
PANEL "N"
150 AMP
120/208v, 1Ø
PANEL "o"
150 AMP
120/208v, 1Ø
PANEL "P"
150 AMP
120/208v, 1Ø
E AB
C
C
C
C C C
DD
C
C
CC
C
C
C
C
D
C
C
C
C
C
D
C C
C
C
C
D
C
EXERCISE
AREA
F
S-106
129.88 SF
V.C.T.
S-105
129.88 SF
V.C.T.
S-103
64.18 SF
V.C.T.
S-101d
82.50 SF
V.C.T.
S-101a
80.62 SF
V.C.T.
S-104
64.18 SF
V.C.T.
S-102 V.C.T.
V.C.T.
V.C.T.
V.C.T.
G-109a V.R.G.
G-109b V.R.G.
G-103a
A-107 V.R.G.
G-108 V.R.G.
A-106 V.C.T.
G-107 V.C.T.
G-106 V.C.T.
G-102
80.00 SF
V.C.T.
G-101 V.C.T.
G-103 V.C.T.
G-103 V.C.T.
G-103c
175.67 SF
V.C.T.
A-101 V.C.T.
A-102 V.C.T.
G-105 V.C.T.
G-104 V.C.T.
A-105 V.C.T.
A-104 V.R.G.
A-103 V.C.T.
K-107 V.C.T.
K-103 V.C.T.
K-104 V.C.T.
K-104a V.C.T.
K-101 V.C.T.
K-102 V.R.G.
K-108 V.C.T.
K-109 V.C.T.
K-111 V.C.T.K-112
V.C.T.
P-106 V.C.T.
V.C.T.
K-105a
V.C.T.
K-105 V.C.T.
P-101 V.C.T.
A-108 V.C.T.
V.C.T.
V.C.T.
V.C.T.
V.C.T.
P-102 V.C.T.
P-103 V.C.T.
V.C.T.
V.C.T.
V.C.T.
A
FLOORS:
NOTE: FLOOR JOISTS IN
UNITS "G & H" FROM 32'-0"
TO 40'-0" TO BE 12" O.C.
I/D UNIT
O/D UNIT
S-101c
S-101b
G-103b
G-102a
K-105b
STAFF
TOILET
JANITOR
A-106 V.R.G.
K-106 V.R.G.
3/0x6/8
C
/0 x6 /8
C
/0 x6
/8
C
3/0x6/8
/0 x6 /8
D
3/0x6/8
E
/0 x6 /8 C
STORAGE
P-105 V.C.T.
3/0x6/8
C
TECH
OFFICE
A-646 V.C.T.
3/0x6/8
CC
CRUTCH
SPLINT/STO
G-107 V.C.T.
OIC
OFFICE
PATIENT
TOILET
3/0x6/8
C
3/0x6/8
C
STORAGE
VACANT
/0 x6 /8
C
DN
DN
30 GAL
W/H
3/0x6/8
C
3/0x6/8
/0 x6 /8
C
ED A
186'-8"
11'-8"
11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8"
25'-0"
60'-0" 62'-0"
186'-8"
11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8"
39'-8"
DN
A B C i K MJ L N o P
3/0x6/8 3/0x6/8 3/0x6/8
/0 x6 /8
3/0x6/8
3/0x6/8 3/0x6/8
3/0x6/8
3/0x6/8 3/0x6/8 3/0x6/8 3/0x6/8 3/0x6/8 3/0x6/8
3/0x6/8
3/0x6/8 3/0x6/83/0x6/8
/0 x6 /8
/0 x6 /8
/0 x6 /8
3/0x6/8
3/0x6/8 3/0x6/8 3/0x6/83/0x6/8
3/0x6/83/0x6/83/0x6/83/0x6/8
3/0x6/8 3/0x6/8
/0 x6 /8
/0 x6 /8
/0 x6 /8
/0 x6 /8
3/0x6/8
3/0x6/8
/0 x6 /8
/0 x6 /8
3/0x6/8 3/0x6/8
3/0x6/83/0x6/8
3/0x6/8 3/0x6/8
/0 x6 /8
3/0x6/83/0x6/8
3/0x6/83/0x6/83/0x6/84/0x6/8 3/0x6/83/0x6/8
MEDICAL
STANDARDS
OFFICE
(MSME)
PROVIDER
OFFICE
PHA
TECHNICIAN
WORKSTATION
PHA
TECHNICIAN
WORKSTATION
NURSE
WORKROOM
SOILED
UTILITY
NCOIC
OFFICE
OIC
OFFICE
PHA
INTERVIEW
ROOM
STAFF
TOILET
JANITOR'S
CLOSET
30 GAL
W/H
ELECTRICAL
ROOM
COMM
ROOM
PHA/DEPLOYMENT
MED/EXAM
ROOM
LPN
OFFICE
NCOIC
OFFICE
OIC
OFFICE
OPTOMETRIST
OFFICE
VISUAL
FIELD
OPTOMETRIST
OFFICE
SUB-WAITING
TOILET
COPY/FILE
DISTRORECEPTIONWAITING
VISUAL
SCREENING
MULTI-DIAGNOSTIC
ROOM
PUBLIC
HEATH
CENTER
AUDIO
TESTINGTECH
OFFICE /
INT OCC
HEALTH
EXAM
ROOM
EXAM
ROOM
IDMT
EXAM
ROOM
EXAM
ROOM
CLEAN
UTILITY
PROVIDER
OFFICE/OICY
PROVIDER
OFFICE
PROVIDER
OFFICE
TECHNOLOGY
OFFICE
STAFF
LOUNGE/TEAM
CONFERENCE
ROOM
TECH
TECH
IDMT
TECH
IDMT
TECH
EXAM
ROOM
EXAM
ROOM
EXAM
ROOM
TREATMENT
ROOM
MULTI-DIAGNOSTIC
ROOM
TECH
RECORD
FIXED
SHELVING
TECHNICIAN
OFFICE/INTERVIEW
COMMUNITY
HEALTH
COPY/FILE
DISTRO
DEPLOYMENT
MED OFFICE
COUNSELING
ROOM
TECHNICIAN
OFFICE/INTERVIEW
COMMUNITY
HEALTH
AUDIO
TESTING
FULL
EYE-LANE
FULL
EYE-LANE
FRAMES
CONTACTS
STORAGE
FOLDED
EYE-LANE
FOLDED
EYE-LANE
FITTING
DISPENSING
AREA
/0 x5 /0
V S
2/0x5/0VS
2/0x5/0VS
2/0x5/0VS
2/0x5/0VS
2/0x5/0VS
2/0x5/0VS
/0 x5 /0
V S
/0 x5 /0
V S
/0 x5 /0
V S
/0 x5 /0
V S
/0 x5 /0
V S
B
B
B
B
B
B
B
B
B
B
B B
B
B
B
B B
B
B
B
B B
B
B
B
B
B
B B
B
B H H H A H H H H H H H H H
D
D
B
B
B
D
B
D
B
B B
B
A B B B B
B B B B B B B B B B B B
B
B B B
B B B
B B B B
D
B
B B B B
BB B B
B B B B
B B
B B
B
B B
B B B B B B B
B
C
B
B
B
B B B F B B B B
B
BBBB
B B
B B
3 3
D
D
B
B
B
B B
B B B
B B8
8 EE
E E
B
B
SITE INSTALLED STRUCT
HEADER; TYP. of (2)
AD
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
60"x12"(D) LAMINATED
COUNTER AT 34" A.F.F.
60"x12"(D) LAMINATED
COUNTER AT 34" A.F.F.
60"x12"(D) LAMINATED
COUNTER AT 34" A.F.F.
C-116
175.44 SF
V.C.T.
C-117
108.00 SF
V.C.T.
C-118b
123.33 SF
V.C.T.
C-122
123.33 SF
V.C.T.
C-120
84.00 SF
V.R.G.
C-124
123.33 SF
V.C.T.
C-125
116.00 SF
V.C.T. D-108
92.00
SF
V.C.T.
A-110
57.85 SF
V.R.G.
A-112
76.00 SF
V.C.T.
D-114
108.00 SF
V.C.T.
D-112
108.00 SF
V.C.T.
D-116
108.00 SF
V.C.T.
D-117
104.00 SF
V.C.T.
D-118
108.00 SF
V.C.T.
D-119
108.00 SF
V.C.T.
E-110
108.00 SF
V.C.T.
E-111
108.00 SF
V.C.T.
E-112
187.78 SF
V.C.T.
E-113
60.00 SF
V.C.T.
E-115
57.17 SF
V.C.T.
E-102a
52.36 SF
V.C.T.
E-102
94.79 SF
V.C.T.
E-101
176.94 SF
V.C.T.
E-103
118.85 SF
V.C.T.
E-104
144.44 SF
V.C.T.
D-107
93.33 SF
V.C.T.
D-106
93.33 SF
V.C.T.
D-103
93.33 SF
V.C.T.
C-104
110.84 SF
V.C.T.
C-106
110.84 SF
V.C.T.
110.84 SF
V.C.T.
C-110
93.33 SF
V.C.T.
C-111
105.63 SF
V.C.T.
C-112
105.63 SF
V.C.T.
C-114
105.63 SF
V.C.T.
C-115
105.63 SF
V.C.T.
C-109
279.56 SF
V.C.T.
C-107
105.15 SF
V.C.T.
C-105
106.08 SF
V.C.T.
C-103
105.15 SF
V.C.T.
C-121
160.06 SF
V.C.T.
C-123
146.81 SF
V.C.T.
A-516
147.00 SF
V.C.T.
D-110
81.00 SF
V.C.T.
C-102a
195.56 SF
V.C.T.
D-115
137.72 SF
V.C.T.
D-113
115.38 SF
V.C.T. D-105
89.33 SF
V.C.T.D-104
89.33 SF
V.C.T.
E-108
200.43 SF
V.C.T.
E-109
200.43 SF
V.C.T.
E-114
108.33 SF
V.C.T.
E-107
156.33 SF
V.C.T.
E-105
156.33 SF
V.C.T.
E-116
108.33 SF
V.C.T.
C-113c
140.00 SF
V.C.T.
PANEL "A"
150 AMP
120/208v, 1Ø
PANEL "B"
150 AMP
120/208v, 1Ø
PANEL "C"
150 AMP
120/208v, 1Ø
PANEL "D"
150 AMP
120/208v, 1Ø
PANEL "E"
150 AMP
120/208v, 1Ø
PANEL "F"
150 AMP
120/208v, 1Ø
PANEL "G"
150 AMP
120/208v, 1Ø
PANEL "H"
150 AMP
120/208v, 1Ø
PANEL "i"
150 AMP
120/208v, 1Ø
PANEL "J"
150 AMP
120/208v, 1Ø PANEL "K"
150 AMP
120/208v, 1Ø
PANEL "L"
150 AMP
120/08v, 1Ø
PANEL "M"
150 AMP
120/208v, 1Ø
PANEL "N"
150 AMP
120/208v, 1Ø
PANEL "o"
150 AMP
120/208v, 1Ø
PANEL "P"
150 AMP
120/208v, 1Ø
(2) 2" CONDUITS
UP THRU FLOOR
I/ D
U N
IT
O/D UNIT
3/4" x 48"x96" PLYWOOD
PAINTED WITH FIRE
RESISTANT PAINT, TYP.
6/0x6/8
/0 x6 /8
B
MULTI-DIAGNOSTIC
ROOM
E-106
148.89 SF
V.C.T.
B 3/0x6/8
E
C-117a c-118a
WAITING
C-101
431.68 SF
V.C.T.
C-108
C-108a
C-113a
C-113b
C-113d
A-511
RECEPTION RECEPTION
C-102 D-102
COPY/FILE
DISTRO
C-102a
3/0x6/8
B
/0 x6 /8
B
3/0x6/8
E
3/0x6/8
E
A
3/0x6/8
B
/0 x6 /8
B
STORAGE
C-117b
63.00 SF
V.C.T.
B
STAFF
TOILET
A-111
57.85 SF
V.R.G.
PHA
INTERVIEW
ROOM
D-109
94.00
SF
V.C.T.
PHA
INTERVIEW
ROOM
D-111
94.00
SF
V.C.T.
3/0x6/8
B 3/0x6/8
B
A 4
24"(D) LAMINATE
COUNTER-TOP @
30" A.F.F.
24"(D) LAMINATE
COUNTER-TOP @
30" A.F.F.
B
STC 50
STC 50 STC 50 STC 50
STC 50STC 50STC 50
A
TNA2.1
B
TNA2.1
H
TNA2.1
C
TNA2.1
D
TNA2.1
G
TNA2.1
E
TNA2.1
F
TNA2.1
E
TNA2.1
F
TNP1.0
STC 50
CORRIDOR
D-101
WAITING
TECH
WORKSTATION
E-116a
3/0x6/8
STORAGE
STAFF
LOUNGE/TEAM
CONFERENCE
ROOM
W3030
B30SB36
W3615
NCO
OFFICE
(SHARED)
C
B-102
82.50 SF
V.C.T.
B-104
343.75 SF
V.C.T.
B-101
94.50 SF
V.C.T.
/0 x6 /8
STAFF
TOILET
D
B-103V.R.G.
/0 x6 /8
E
3/0x6/8
C
ON-CALL
ROOM
B-105
66.00 SF
V.C.T.
/0 x6 /8
C
KITCHEN
B-104a
ACCESS
36"x48"
3/0x6/8
C
ON-CALL
ROOM
B-106
66.00 SF
V.C.T.
3/0x6/8
A
VALID
January 27, 2017
File details come from the government source that posted it.