29_02_TNA3.0_Reflective_Ceiling_Plan.pdf

PDF 920 KB Posted

Attached to
Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
Solicitation number
W9127S19Q6039
Issued by
Department of the Army Corps of Engineers Engineering District Little Rock

About this file

Part of Attachment I - As-Builts, 29-TPF North Public Health

View the file

Other files for this federal contract opportunity

Other files attached to Tyndall AFB Temporary Modular Medical Facility, newest first.
File Type Posted
49_22__TLV2.0_Combined_Clinic_TPF_Low_Voltage_Systems_Notes_&_Details.pdf PDF
1-V1.07_SURVEY_PLAN.pdf PDF
1-V1.02_SURVEY_PLAN.pdf PDF
49_24__TPF2.0_Full_Building_Plan.pdf PDF
49_23__TCP1.4-PII_Combined_Clinic_TPF_RCP-PHASE_II.PDF PDF
1-V1.06_SURVEY_PLAN.pdf PDF
49_24__TPF6.0_Overall_Plumbing_Plan_-_Supply.pdf PDF
49_21__TFP3.1_Combined_Clinic_TPF_Fire_Suppression_Plan_Phase_1.pdf PDF
49_23__TCP1.1_Combined_Clinic_TPF_RCP.pdf PDF
49_25__TPFV1.0_COVER_SHEET_STAMPED.pdf PDF
49_25__TPFV8.0_CANOPY_ASSEMBLY_AND_FOOTING_DETAILS_STAMPED.pdf PDF
55_TQ3.11D_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_D.pdf PDF
55_TQ4.11_-_FFE_PLAN_-_TPF_PHASE_2.pdf PDF
49_21__TFP1.0_Combined_Clinic_TPF_Life_Safety_Narrative.pdf PDF
55_TQ4.11D_-_FFE_PLAN_-_TPF_PHASE_2,_AREA_D.pdf PDF
49_23__TCP1.5_Combined_Clinic_TPF_RCP.pdf PDF
49_25__TPFV2.0_STANDARD_RAMP_AND_STAIR_DETAILS_STAMPED.pdf PDF
49_24__TPF2.0-PI_Full_Building_Plan-Phase_1.pdf PDF
1-V1.01_SURVEY_PLAN.pdf PDF
49_23__TCP1.3_Combined_Clinic_TPF_RCP.pdf PDF
55_TQ4.01_-_FFE_JSN_LEGEND.pdf PDF
1-V1.05_SURVEY_PLAN.pdf PDF
36_12_TSM1.0_Mechanical_HVAC_Plan.pdf PDF
29_03_TNP4.0_Plumbing_Plan_-_DWV.pdf PDF
29_01_TNC1.0_Cover_Sheet-Notes.pdf PDF
29_03_TNP1.0_Plumbing_Schematics.pdf PDF
43_19_TCCX2.0_Roof_Drain_Details.pdf PDF
43_19_TCCX1.0_Building_Cross_Section.pdf PDF
29_07_TNFD1.0_Foundation_Plan_and_Details.pdf PDF
36_11_TSE1.1_Electrical_Panel_Schedules.pdf PDF
36_10_TSP3.0_Plumbing_Plan_-_Supply_Phase_1.pdf PDF
05_1-CU1.01_UTILITY_PLAN_-_PHASE_1.pdf PDF
43_20_TCCFD1.0_Foundation_Plan_and_Details.pdf PDF
36_09_TSA4.0-PII_Egress_Plan.pdf PDF
07_ES1-01_-_ELECTRICAL_SITE_PLAN_-_MEDICAL_CLINIC_BUILDING_1465.pdf PDF
36_11_TSE3.0-PII_Task_Lighting_Illumination_Plan_Phase_2.pdf PDF
36_10_TSP2.0_Plumbing_Schematics.pdf PDF
36_14_TSFD1.0_Foundation_Plan_and_Details.pdf PDF
36_11_TSE4.0_MDP_-_One_Line_Diagram.pdf PDF
36_09_TSA3.0-PII_Reflective_Ceiling_Plan.pdf PDF
29_04_TNE1.0_Elec_Plan.pdf PDF
36_12_TSM1.0-PII_Mechanical_HVAC_Plan.pdf PDF
43_16_TCCA2.0_Floor_Plan.pdf PDF
36_10_TSP4.0_Plumbing_Plan_-_DWV_Phase_1.pdf PDF
36_11_TSE1.0-PII_Electrical_Plan.pdf PDF
36_09_TSA2.1_Interior_Elevations.pdf PDF
29_02_TNA1.0_Exterior_Elevations.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Combined_Synopsis_Solicitation_13Aug19.pdf PDF
Attachment_F_-_Codes_&_Criteria.pdf PDF
Attachment_D_-_DHA_LAN_WLAN_Guides.pdf PDF
Show all 50

Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE: 3/16"=1'-0"

REFLECTIVE CEILING PLAN

A

54321

B

C

D

E

B A

S E

C

IV

IL

E

N G

IN

E

E R

/D E

P U

T Y

C H

IE

F

E N

G

IN

E E

R

IN

G F

L

IG

H T

C

E P

C H

IE

F

C O

N T

R A

C T

S S

E C

T

IO

N

C E

P M

R E

C O

M M

E N

D E

D

R E

C O

M M

E N

D E

D

A P

P R

O V

E D

R E

V D

A T

E E

N G

IN

E

E R

\D E

S

IG

N E

R

D R

A W

N B

Y

S C

A L

E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

C O

N T

R A

C T

N U

M B

E R

D E

S

IG

N T

E A

M C

E P

M

U S

IN

G

A G

E N

C Y

C H

E C

K E

D B

Y

H O

E F

E R

W Y

S O

C K

I A

R C

H

IT

E C

T S

/3

/2

JE DUNN + HWA

CLEARWATER, FL 33756

CONSULTING ENGINEER

1765 CARNEGIE AVENUE

Ph: (727) 505-9941

JAMES E. BRADLEY, P.E.

J E B

0' 4' 8' 16' 32'

1/8" = 1'-0"

0' 2' 4' 8' 16'

1/4" = 1'-0"

0' 1' 2'

3/4" = 1'-0"

4'0' 1'

1 1/2" = 1'-0"

2' 2'1'6"6"3"0' 6"

3" = 1'-0"

1'3"

2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930

TPF TYNDALL - NORTH

PUBLIC HEALTH BLDG

S U

B M

IT

T

A L

C O

R R

E C

T E

D F

IN

A

L

J A

M E

S E

B

R A

D L

E Y

P

.E

J .L

.B

J .E

.B

J E

D U

N N

W

-1

-R -6

W

-1

-D -6

A S

I N

D

IC

A T

E D

THIRD PARTY:

& ASSOCIATES

HILBORN, WERNER, CARTER

1627 SOUTH MYRTLE AVE.

CLEARWATER, FLORIDA 33756

R E

F L

E C

T

IV

E C

E

IL

IN

G

P L

A N

T Y

N D

A L

L A

F B

P U

B L

IC

H

E A

L T

H B

L D

G

TNA3.0

M

A G

N O

L

IA

C

IR

C L

E T

Y N

D A

L L

A F

B

F L

S y m b o l

D es cr ip ti o n

T ra ck in g N o

A ct io n

D at e

T-GRID SYMBOLS

DUCT WITH FLEX DUCT DROP

TO CEILING REGISTERS (RETURN)

(UNLESS NOTED OTHERWISE)

8" FLEX DUCT - RETURN

(UNLESS NOTED OTHERWISE)

8" FLEX DUCT - SUPPLY

TO CEILING REGISTERS (SUPPLY)

OVERHEAD FIBERGLASS RIGID

DUCT WITH FLEX DUCT DROP

OVERHEAD FIBERGLASS RIGID

2'x2' SUPPLY AIR REGISTER

TROFFER PER SPECS.

2'x2' RETURN AIR REGISTER

2'x4' FLOURESCENT (2 TUBE 32w - 64w MAX)

EXHAUST FAN-100 CFM (UNLESS NOTED)

(NOTE: MANUAL VOLUME CONTROL DAMPERS

TO BE LOCATED AT EACH TAKE OFF)

(NOTE: MANUAL VOLUME CONTROL DAMPERS

TO BE LOCATED AT EACH TAKE OFF)

NOTE:

1. SUSPENDED CEILING SURFACES CANNOT BE USED FOR THE DIRECT SUPPORT OF

CUBICLE TRACKS AND CEILING LIGHTS. CEILING MOUNTED ACCESSORIES SHALL BE

SECURED THROUGH THE CEILING TO SECONDARY SUPPORT MEMEBERS.

2. RE TCP1.0 FOR RCP COORDINATION DRAWING.

3. RE TPF3.0 FOR OVERALL LUMINARY PLAN

A-2

B-2

A-2

A-2

B-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

A-2

C-2

C-2

B-2

B-2

B-2

B-2

B-2

B-2

B-2 B-2 B-2 B-2

B-2 B-2 B-2 B-2 i-2 i-2 i-2 i-2 i-2 i-2 i-2 i-2

B-2

B-2

B-2 i-2 i-2 o-2 i-2 i-2 i-2 o-2 o-2 o-2 o-2 o-2 o-2 o-2

B-2

B-2

C-2

C-2

D-2

D-2

E-2

E-2

H-2

H-2

H-2

H-2

H -2

H-2

H-2

B -2 J-2

J-2

J-2

J-2

K-2

K-2

N-2N-2 o-2 o-2 o-2

P-2

P-2

P-2

P-2

P-2

P-2

D -2

E-2

E-2

F-2

F-2

G-2

G-2

K-2

K-2

L-2

L-2

M-2

M-2

M-2

M-2

N-2

N-2 o-2 o-2

J-2

J-2i-2

H-2G-2

D-2

C-2

C-2

C-2

D-2D-2 D-2

D-2D-2 E-2E-2 F-2F-2

E-2 E-2 G-2

H-2

G-2 H-2

G-2 H-2

H-2 i-2 i-2

J-2 K-2

J-2

J-2

K-2

K-2

L-2 L-2 M-2 M-2 o-2 o-2

M-2

M-2

M-2

N-2

N-2

N-2

WALL MOUNTED MINI-SPLIT

A/C UNIT; (COOLING ONLY)

FREDRICH (350 CFM); BOTTOM

OF UNIT TO BE AT 80" A.F.F.

OUTDOOR CONDENSING UNT; FREDRICH

#MR12CH; OUTSIDE CONDENSING UNIT

(12,300 BTUH COOLING ONLY); ALL

CONDENSATE LINES AND WIRING TO

INDOOR UNITS ARE TO BE SITE

INSTALLED BY SMM; UNIT IS SHIPPED

LOOSE AND SITE INSTALLED

T

T

T T

T T T

T

T T T T T T T T o-2 P-2

P-2

P-2

A B C i K MJ L N o P

MEDICAL

STANDARDS

OFFICE

(MSME)

PROVIDER

OFFICE

PHA

TECHNICIAN

WORKSTATION

PHA

TECHNICIAN

WORKSTATION

NURSE

WORKROOM

SOILED

UTILITY

NCOIC

OFFICE

SHPE OFFICE

INTERVIEW

PHA

INTERVIEW

ROOM

STAFF

TOILET

JANITOR'S

CLOSET

ELECTRICAL

ROOM

COMM

ROOM

PHA/DEPLOYMENT

MED/EXAM

ROOM

LPN

OFFICE

NCOIC

OFFICE

OIC

OFFICE

OPTOMETRIST

OFFICE

VISUAL

FIELD

OPTOMETRIST

OFFICE

SUB-WAITING

TOILET

COPY/FILE

DISTRORECEPTIONWAITING

VISUAL

SCREENING

MULTI-DIAGNOSTIC

ROOM

PUBLIC

HEATH

CENTER

AUDIO

TESTINGTECH

OFFICE /

INT OCC

HEALTH

EXAM

ROOM

EXAM

ROOM

IDMT

EXAM

ROOM

CLEAN

UTILITY

PROVIDER

OFFICE/OICY

PROVIDER

OFFICE

PROVIDER

OFFICE

TECHNOLOGY

OFFICE

STAFF

LOUNGE/TEAM

CONFERENCE

ROOM

TECH

TECH

IDMT

TECH

IDMT

TECH

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

TREATMENT

ROOM

MULTI-DIAGNOSTIC

ROOM

TECH

RECORD

FIXED

SHELVING

TECHNICIAN

OFFICE/INTERVIEW

COMMUNITY

HEALTH

COPY/FILE

DISTRO

DEPLOYMENT

MED OFFICE

COUNSELING

ROOM

TECHNICIAN

OFFICE/INTERVIEW

COMMUNITY

HEALTH

AUDIO

TESTING

FULL

EYE-LANE

FULL

EYE-LANE

FRAMES

CONTACTS

STORAGE

FOLDED

EYE-LANE

FOLDED

EYE-LANE

FITTING

DISPENSING

AREA

EXIT BEXIT B

EXIT BEXIT B EXIT B

PANEL "A"

150 AMP

120/208v, 1Ø

PANEL "B"

150 AMP

120/208v, 1Ø

PANEL "C"

150 AMP

120/208v, 1Ø

PANEL "D"

150 AMP

120/208v, 1Ø

PANEL "E"

150 AMP

120/208v, 1Ø

PANEL "F"

150 AMP

120/208v, 1Ø

PANEL "G"

150 AMP

120/208v, 1Ø

PANEL "H"

150 AMP

120/208v, 1Ø

PANEL "i"

150 AMP

120/208v, 1Ø

PANEL "J"

150 AMP

120/208v, 1Ø PANEL "K"

150 AMP

120/208v, 1Ø

PANEL "L"

150 AMP

120/08v, 1Ø

PANEL "M"

150 AMP

120/208v, 1Ø

PANEL "N"

150 AMP

120/208v, 1Ø

PANEL "o"

150 AMP

120/208v, 1Ø

PANEL "P"

150 AMP

120/208v, 1Ø

I/ D

U N

IT

O/D UNIT

MULTI-DIAGNOSTIC

ROOM

EXIT B

W.P.

w/P.C.

WAITING

RECEPTION RECEPTION

COPY/FILE

DISTRO

3.0 TON WALL HUNG HVAC UNIT

(MD#:W36A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 1000 CFM @ .4 IWC ESP

w/25% FRESH AIR INTAKE; 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTERS;

TYP. of (16)

3.0 TON WALL HUNG HVAC UNIT

(MD#:W36A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 1000 CFM @ .4 IWC ESP

w/25% FRESH AIR INTAKE; 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTERS;

TYP. of (16)

3.0 TON WALL HUNG HVAC UNIT

(MD#:W36A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 1000 CFM @ .4 IWC ESP

w/25% FRESH AIR INTAKE; 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTERS;

TYP. of (16)

EXIT BEXIT B

STORAGE

STAFF

TOILET

PHA

INTERVIEW

ROOM

PHA

INTERVIEW

ROOM

D-2

G-2 H-2

P-2 i-2 i-2

G-2

H-2

H-2

EXIT B

i-2

NOTE: DO NOT INSTALL

REMOTE HEADS IN CORRIDOR

INSTALL PLATES, TYP.

NOTE: DO NOT INSTALL

REMOTE HEADS IN CORRIDOR

INSTALL PLATES, TYP.

CORRIDOR

WAITING

TECH

WORKSTATION

D E F G H

VALID

January 27, 2017

File details come from the government source that posted it.