SCALE: 3/16"=1'-0"
REFLECTIVE CEILING PLAN
A
54321
B
C
D
E
B A
S E
C
IV
IL
E
N G
IN
E
E R
/D E
P U
T Y
C H
IE
F
E N
G
IN
E E
R
IN
G F
L
IG
H T
C
E P
C H
IE
F
C O
N T
R A
C T
S S
E C
T
IO
N
C E
P M
R E
C O
M M
E N
D E
D
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
R E
V D
A T
E E
N G
IN
E
E R
\D E
S
IG
N E
R
D R
A W
N B
Y
S C
A L
E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
C O
N T
R A
C T
N U
M B
E R
D E
S
IG
N T
E A
M C
E P
M
U S
IN
G
A G
E N
C Y
C H
E C
K E
D B
Y
H O
E F
E R
W Y
S O
C K
I A
R C
H
IT
E C
T S
/3
/2
JE DUNN + HWA
CLEARWATER, FL 33756
CONSULTING ENGINEER
1765 CARNEGIE AVENUE
Ph: (727) 505-9941
JAMES E. BRADLEY, P.E.
J E B
0' 4' 8' 16' 32'
1/8" = 1'-0"
0' 2' 4' 8' 16'
1/4" = 1'-0"
0' 1' 2'
3/4" = 1'-0"
4'0' 1'
1 1/2" = 1'-0"
2' 2'1'6"6"3"0' 6"
3" = 1'-0"
1'3"
2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930
TPF TYNDALL - NORTH
PUBLIC HEALTH BLDG
S U
B M
IT
T
A L
C O
R R
E C
T E
D F
IN
A
L
J A
M E
S E
B
R A
D L
E Y
P
.E
J .L
.B
J .E
.B
J E
D U
N N
W
-1
-R -6
W
-1
-D -6
A S
I N
D
IC
A T
E D
THIRD PARTY:
& ASSOCIATES
HILBORN, WERNER, CARTER
1627 SOUTH MYRTLE AVE.
CLEARWATER, FLORIDA 33756
R E
F L
E C
T
IV
E C
E
IL
IN
G
P L
A N
T Y
N D
A L
L A
F B
P U
B L
IC
H
E A
L T
H B
L D
G
TNA3.0
M
A G
N O
L
IA
C
IR
C L
E T
Y N
D A
L L
A F
B
F L
S y m b o l
D es cr ip ti o n
T ra ck in g N o
A ct io n
D at e
T-GRID SYMBOLS
DUCT WITH FLEX DUCT DROP
TO CEILING REGISTERS (RETURN)
(UNLESS NOTED OTHERWISE)
8" FLEX DUCT - RETURN
(UNLESS NOTED OTHERWISE)
8" FLEX DUCT - SUPPLY
TO CEILING REGISTERS (SUPPLY)
OVERHEAD FIBERGLASS RIGID
DUCT WITH FLEX DUCT DROP
OVERHEAD FIBERGLASS RIGID
2'x2' SUPPLY AIR REGISTER
TROFFER PER SPECS.
2'x2' RETURN AIR REGISTER
2'x4' FLOURESCENT (2 TUBE 32w - 64w MAX)
EXHAUST FAN-100 CFM (UNLESS NOTED)
(NOTE: MANUAL VOLUME CONTROL DAMPERS
TO BE LOCATED AT EACH TAKE OFF)
(NOTE: MANUAL VOLUME CONTROL DAMPERS
TO BE LOCATED AT EACH TAKE OFF)
NOTE:
1. SUSPENDED CEILING SURFACES CANNOT BE USED FOR THE DIRECT SUPPORT OF
CUBICLE TRACKS AND CEILING LIGHTS. CEILING MOUNTED ACCESSORIES SHALL BE
SECURED THROUGH THE CEILING TO SECONDARY SUPPORT MEMEBERS.
2. RE TCP1.0 FOR RCP COORDINATION DRAWING.
3. RE TPF3.0 FOR OVERALL LUMINARY PLAN
A-2
B-2
A-2
A-2
B-2
A-2
A-2
A-2
A-2
A-2
A-2
A-2
A-2
C-2
C-2
B-2
B-2
B-2
B-2
B-2
B-2
B-2 B-2 B-2 B-2
B-2 B-2 B-2 B-2 i-2 i-2 i-2 i-2 i-2 i-2 i-2 i-2
B-2
B-2
B-2 i-2 i-2 o-2 i-2 i-2 i-2 o-2 o-2 o-2 o-2 o-2 o-2 o-2
B-2
B-2
C-2
C-2
D-2
D-2
E-2
E-2
H-2
H-2
H-2
H-2
H -2
H-2
H-2
B -2 J-2
J-2
J-2
J-2
K-2
K-2
N-2N-2 o-2 o-2 o-2
P-2
P-2
P-2
P-2
P-2
P-2
D -2
E-2
E-2
F-2
F-2
G-2
G-2
K-2
K-2
L-2
L-2
M-2
M-2
M-2
M-2
N-2
N-2 o-2 o-2
J-2
J-2i-2
H-2G-2
D-2
C-2
C-2
C-2
D-2D-2 D-2
D-2D-2 E-2E-2 F-2F-2
E-2 E-2 G-2
H-2
G-2 H-2
G-2 H-2
H-2 i-2 i-2
J-2 K-2
J-2
J-2
K-2
K-2
L-2 L-2 M-2 M-2 o-2 o-2
M-2
M-2
M-2
N-2
N-2
N-2
WALL MOUNTED MINI-SPLIT
A/C UNIT; (COOLING ONLY)
FREDRICH (350 CFM); BOTTOM
OF UNIT TO BE AT 80" A.F.F.
OUTDOOR CONDENSING UNT; FREDRICH
#MR12CH; OUTSIDE CONDENSING UNIT
(12,300 BTUH COOLING ONLY); ALL
CONDENSATE LINES AND WIRING TO
INDOOR UNITS ARE TO BE SITE
INSTALLED BY SMM; UNIT IS SHIPPED
LOOSE AND SITE INSTALLED
T
T
T T
T T T
T
T T T T T T T T o-2 P-2
P-2
P-2
A B C i K MJ L N o P
MEDICAL
STANDARDS
OFFICE
(MSME)
PROVIDER
OFFICE
PHA
TECHNICIAN
WORKSTATION
PHA
TECHNICIAN
WORKSTATION
NURSE
WORKROOM
SOILED
UTILITY
NCOIC
OFFICE
SHPE OFFICE
INTERVIEW
PHA
INTERVIEW
ROOM
STAFF
TOILET
JANITOR'S
CLOSET
ELECTRICAL
ROOM
COMM
ROOM
PHA/DEPLOYMENT
MED/EXAM
ROOM
LPN
OFFICE
NCOIC
OFFICE
OIC
OFFICE
OPTOMETRIST
OFFICE
VISUAL
FIELD
OPTOMETRIST
OFFICE
SUB-WAITING
TOILET
COPY/FILE
DISTRORECEPTIONWAITING
VISUAL
SCREENING
MULTI-DIAGNOSTIC
ROOM
PUBLIC
HEATH
CENTER
AUDIO
TESTINGTECH
OFFICE /
INT OCC
HEALTH
EXAM
ROOM
EXAM
ROOM
IDMT
EXAM
ROOM
CLEAN
UTILITY
PROVIDER
OFFICE/OICY
PROVIDER
OFFICE
PROVIDER
OFFICE
TECHNOLOGY
OFFICE
STAFF
LOUNGE/TEAM
CONFERENCE
ROOM
TECH
TECH
IDMT
TECH
IDMT
TECH
EXAM
ROOM
EXAM
ROOM
EXAM
ROOM
TREATMENT
ROOM
MULTI-DIAGNOSTIC
ROOM
TECH
RECORD
FIXED
SHELVING
TECHNICIAN
OFFICE/INTERVIEW
COMMUNITY
HEALTH
COPY/FILE
DISTRO
DEPLOYMENT
MED OFFICE
COUNSELING
ROOM
TECHNICIAN
OFFICE/INTERVIEW
COMMUNITY
HEALTH
AUDIO
TESTING
FULL
EYE-LANE
FULL
EYE-LANE
FRAMES
CONTACTS
STORAGE
FOLDED
EYE-LANE
FOLDED
EYE-LANE
FITTING
DISPENSING
AREA
EXIT BEXIT B
EXIT BEXIT B EXIT B
PANEL "A"
150 AMP
120/208v, 1Ø
PANEL "B"
150 AMP
120/208v, 1Ø
PANEL "C"
150 AMP
120/208v, 1Ø
PANEL "D"
150 AMP
120/208v, 1Ø
PANEL "E"
150 AMP
120/208v, 1Ø
PANEL "F"
150 AMP
120/208v, 1Ø
PANEL "G"
150 AMP
120/208v, 1Ø
PANEL "H"
150 AMP
120/208v, 1Ø
PANEL "i"
150 AMP
120/208v, 1Ø
PANEL "J"
150 AMP
120/208v, 1Ø PANEL "K"
150 AMP
120/208v, 1Ø
PANEL "L"
150 AMP
120/08v, 1Ø
PANEL "M"
150 AMP
120/208v, 1Ø
PANEL "N"
150 AMP
120/208v, 1Ø
PANEL "o"
150 AMP
120/208v, 1Ø
PANEL "P"
150 AMP
120/208v, 1Ø
I/ D
U N
IT
O/D UNIT
MULTI-DIAGNOSTIC
ROOM
EXIT B
W.P.
w/P.C.
WAITING
RECEPTION RECEPTION
COPY/FILE
DISTRO
3.0 TON WALL HUNG HVAC UNIT
(MD#:W36A2-A10XP) INSTALLED
PER MFG'R SPEC'S w/7.5 kW HEAT
STRIP; 1000 CFM @ .4 IWC ESP
w/25% FRESH AIR INTAKE; 208v 1Ø;
w/2 INCH MERV-8 PLEATED FILTERS;
TYP. of (16)
3.0 TON WALL HUNG HVAC UNIT
(MD#:W36A2-A10XP) INSTALLED
PER MFG'R SPEC'S w/7.5 kW HEAT
STRIP; 1000 CFM @ .4 IWC ESP
w/25% FRESH AIR INTAKE; 208v 1Ø;
w/2 INCH MERV-8 PLEATED FILTERS;
TYP. of (16)
3.0 TON WALL HUNG HVAC UNIT
(MD#:W36A2-A10XP) INSTALLED
PER MFG'R SPEC'S w/7.5 kW HEAT
STRIP; 1000 CFM @ .4 IWC ESP
w/25% FRESH AIR INTAKE; 208v 1Ø;
w/2 INCH MERV-8 PLEATED FILTERS;
TYP. of (16)
EXIT BEXIT B
STORAGE
STAFF
TOILET
PHA
INTERVIEW
ROOM
PHA
INTERVIEW
ROOM
D-2
G-2 H-2
P-2 i-2 i-2
G-2
H-2
H-2
EXIT B
i-2
NOTE: DO NOT INSTALL
REMOTE HEADS IN CORRIDOR
INSTALL PLATES, TYP.
NOTE: DO NOT INSTALL
REMOTE HEADS IN CORRIDOR
INSTALL PLATES, TYP.
CORRIDOR
WAITING
TECH
WORKSTATION
D E F G H
VALID
January 27, 2017