SCALE: 3/16"=1'-0"
REFLECTIVE CEILING PLAN - PHASE 2
A
54321
B
C
D
E
B A
S E
C
IV
IL
E
N G
IN
E
E R
/D E
P U
T Y
C H
IE
F
E N
G
IN
E E
R
IN
G F
L
IG
H T
C
E P
C H
IE
F
C O
N T
R A
C T
S S
E C
T
IO
N
C E
P M
R E
C O
M M
E N
D E
D
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
R E
V D
A T
E E
N G
IN
E
E R
\D E
S
IG
N E
R
D R
A W
N B
Y
S C
A L
E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
C O
N T
R A
C T
N U
M B
E R
D E
S
IG
N T
E A
M C
E P
M
U S
IN
G
A G
E N
C Y
C H
E C
K E
D B
Y
H O
E F
E R
W Y
S O
C K
I A
R C
H
IT
E C
T S
/3
/2
JE DUNN + HWA
CLEARWATER, FL 33756
CONSULTING ENGINEER
1765 CARNEGIE AVENUE
Ph: (727) 505-9941
JAMES E. BRADLEY, P.E.
J E B
0' 4' 8' 16' 32'
1/8" = 1'-0"
0' 2' 4' 8' 16'
1/4" = 1'-0"
0' 1' 2'
3/4" = 1'-0"
4'0' 1'
1 1/2" = 1'-0"
2' 2'1'6"6"3"0' 6"
3" = 1'-0"
1'3"
2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930
TPF TYNDALL - SOUTH
AMBULANCE SERVICES BLDG
A S
I N
D
IC
A T
E D
J A
M E
S E
B
R A
D L
E Y
P
.E
W
-1
-R -6
W
-1
-D -6
J .L
.B
J E
D U
N N
J .E
.B
S U
B M
IT
T
A L
C O
R R
E C
T E
D F
IN
A
L
& ASSOCIATES
HILBORN, WERNER, CARTER
1627 SOUTH MYRTLE AVE.
CLEARWATER, FLORIDA 33756
THIRD PARTY: R
E
F L
E C
T
IV
E C
E
IL
IN
G
P L
A N
T Y
N D
A L
L A
F B
A M
B U
L A
N C
E S
E R
V
IC
E S
B L
D G
TS
A3.0-PII
M
A G
N O
L
IA
C
IR
C L
E T
Y N
D A
L L
A F
B
F L
S y m b o l D es cr ip ti o n
T ra ck in g N o
A ct io n
D at e
NOTE: SUSPENDED CEILING SURFACES CANNOT BE USED FOR THE DIRECT SUPPORT OF
CUBICLE TRACKS AND CEILING LIGHTS. CEILING MOUNTED ACCESSORIES SHALL BE
SECURED THROUGH THE CEILING TO SECONDARY SUPPORT MEMEBERS,.
T-GRID SYMBOLS
DUCT WITH FLEX DUCT DROP
TO CEILING REGISTERS (RETURN)
(UNLESS NOTED OTHERWISE)
8" FLEX DUCT - RETURN
(UNLESS NOTED OTHERWISE)
8" FLEX DUCT - SUPPLY
TO CEILING REGISTERS (SUPPLY)
OVERHEAD FIBERGLASS RIGID
DUCT WITH FLEX DUCT DROP
OVERHEAD FIBERGLASS RIGID
2'x2' SUPPLY AIR REGISTER
TROFFER PER SPECS.
2'x2' RETURN AIR REGISTER
2'x4' FLOURESCENT (2 TUBE 32w BULBS - 64w MAX)
EXHAUST FAN-100 CFM (UNLESS NOTED)
(NOTE: MANUAL VOLUME CONTROL DAMPERS
TO BE LOCATED AT EACH TAKE OFF)
(NOTE: MANUAL VOLUME CONTROL DAMPERS
TO BE LOCATED AT EACH TAKE OFF)
H-2 H-2
H-2 H-2
G-2
G -2
G-2
G -2
H-2
H-2
H-2
H-2
H-2
H-2
H-2
H-2
H-2 i-2i-2 i-2
L-2
L-2
N-2
J-2
K-2
K-2
K-2
K-2
K-2
K-2
K-2 N-2
K-2 i-2 i-2 i-2
J-2
J-2
J-2 i-i-6 i-6 i-2
K-2
K-2
K-2
K-2
L-2L-2L-2 L-2 L-2
M-2
L-2 L-2
L-2 L-2
K-2 o-2
N-2
N-2
P-2P-2
P-2
P-2
M-2P o-2 o-2 o-2 o-2 o-2 o-2 o-2
P-2 o-2
P-2 o-2 o-2 o-2 o-2 o-2
J-2
WALL MOUNTED MINI-SPLIT
A/C UNIT; (COOLING ONLY)
FREDRICH (350 CFM); BOTTOM
OF UNIT TO BE AT 80" A.F.F.
OUTDOOR CONDENSING UNT; FREDRICH
#MR12CH; OUTSIDE CONDENSING UNIT
(12,300 BTUH COOLING ONLY); ALL
CONDENSATE LINES AND WIRING TO
INDOOR UNITS ARE TO BE SITE
INSTALLED BY SMM; UNIT IS SHIPPED
LOOSE AND SITE INSTALLED
N-2
N-2
N-2
N-2
N-2
K-2 o-2M-2 o-2
N-2
NOTE:
CEILING HEIGHT IN "EXCERCISE
AREA" TO BE MINIMUM OF
9'-0"; MODULES "E" & "F" AND
ONLY
NOTE:
CEILING HEIGHT IN "EXCERCISE
AREA" TO BE MINIMUM OF
9'-0"; MODULES "E" & "F" AND
ONLY
D
A B C D E F G H i J K L M N o P
STORAGE
STAFF
LOUNGE/TEAM
CONFERENCE
ROOM
NCO
OFFICE
(SHARED)
PERSONAL
PROPERTY
LOCKERS
PATIENT
TOILET
STAFF
TOILET JANITOR'S
CLOSET
STAFF
LOUNGE /
CONFERENCE
ROOM
WAITING
COMM
ROOM
SHIPPING/
RECEIVING
TECHNICAL
SUPERVISOR
SHARED
NCOIC
OFFICE
OIC
OFFICE
CENTRAL
STORAGE
M/TLT
MICRO
BIOLOGY
JANITOR
F/TLT
SPECIMEN
TOILET
WAITING
RECEPTION
COPY/FILE
DISTRO
TECH
TECH
BLOOD
DRAW AREA
CORE
LAB
STAFF
LOUNGE/TEAM
CONFERENCE
ROOM
PANEL "A"
150 AMP
120/208v, 1Ø
PANEL "B"
150 AMP
120/208v, 1Ø
PANEL "C"
150 AMP
120/208v, 1Ø
PANEL "D"
150 AMP
120/208v, 1Ø
PANEL "E"
150 AMP
120/208v, 1Ø
PANEL "F"
150 AMP
120/208v, 1Ø
PANEL "G"
150 AMP
120/208v, 1Ø
PANEL "H"
150 AMP
120/208v, 1Ø
PANEL "i"
150 AMP
120/208v, 1Ø
PANEL "J"
150 AMP
120/208v, 1Ø
PANEL "K"
150 AMP
120/208v, 1Ø PANEL "L"
150 AMP
120/208v, 1Ø
PANEL "M"
150 AMP
120/208v, 1Ø
PANEL "N"
150 AMP
120/208v, 1Ø
PANEL "o"
150 AMP
120/208v, 1Ø
PANEL "P"
150 AMP
120/208v, 1Ø
EXERCISE
AREA
B-102
B-104
B-101
S-102 G-109aG-109b
A-107
G-108
A-106 G-107 G-106
G-101
G-103
G-103
A-101
A-102
G-105
G-104
A-105
A-104
A-103
K-107
K-103
K-104
K-104a
K-101
K-102
K-108 K-109
K-111 K-112
P-106
K-105a
K-105
P-101
A-108
P-102
P-103
EXIT B
W.P.
w/P.C.
EXIT B
W.P.
w/P.C.
EXIT B
EXIT BEXIT BEXIT BEXIT B
W.P.
w/P.C.
EXIT B
EXIT B
EXIT B
I/D UNIT
O/D UNIT
STAFF
TOILET
B-103
ON-CALL
ROOM
B-105
KITCHEN
B-104a
K-105b
STAFF
TOILET
JANITOR
A-106 K-106
EXIT B
P-105
A-646
G-107
PATIENT
TOILET
i-2 i-2
M-2
M-2
N-2
N-2
M-2 o-2
M-2 o-2M-2M-2
P-2P-2
HSMR
STORAGE
STORAGE
FIT
LIBRARY
OFFICEOFFICE
STORAGE
BEE
WORK ROOM
OFFICE
LAB
VACANTVACANT
BMET
VACANT
VACANT
VACANT
VACANT
VACANT
DN
DN
A-2A-2
A-2A-2
A-2
A-2
A-2
A-2
A-2
A-2
B-2 B-2
B-2 B-2
B-2 B-2 A-2
B-2
B-2
A-2 D-2
C-2
E-2 F-2
C-2 C-2
C-2
C-2
C-2
A-2
E-2
E-2
E-2
E-2
D-2 D-2
D-2 D-2 G-2
D-2 E-2
E-2 E-2
G-2
G-2
NOTE: DO NOT INSTALL
REMOTE HEADS IN CORRIDOR
INSTALL PLATES, TYP.
NOTE: DO NOT INSTALL
REMOTE HEADS IN CORRIDOR
INSTALL PLATES, TYP.STUB SUPPLY GRILLE
THRU ENDWALL INTO
CORRIDOR
STUB SUPPLY GRILLE
THRU ENDWALL INTO
CORRIDOR
ON-CALL
ROOM
B-106
DN
A-2
E-2 E-2E-2E-2
E-2 E-2E-2E-2
G-2 G-2G-2G-2
G-2 G-2G-2G-2
D-2 D-2
VALID
January 27, 2017
File details come from the government source that posted it.