43_16_TCCA2.0_Floor_Plan.pdf
PDF 1 MB Posted
- Attached to
- Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
- Solicitation number
- W9127S19Q6039
About this file
Part of Attachment I - As-Builts, 43-TPF Corridor
View the file
Other files for this federal contract opportunity
Show all 50
Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE: 3/16"=1'-0"
FLOOR PLAN
A
54321
B
C
D
E
B A
S E
C
IV
IL
E
N G
IN
E
E R
/D E
P U
T Y
C H
IE
F
E N
G
IN
E E
R
IN
G F
L
IG
H T
C
E P
C H
IE
F
C O
N T
R A
C T
S S
E C
T
IO
N
C E
P M
R E
C O
M M
E N
D E
D
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
R E
V D
A T
E E
N G
IN
E
E R
\D E
S
IG
N E
R
D R
A W
N B
Y
S C
A L E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
C O
N T
R A
C T
N U
M B
E R
D E
S
IG
N T
E A
M C
E P
M
U S
IN
G
A G
E N
C Y
C H
E C
K E
D B
Y
H O
E F
E R
W Y
S O
C K
I
A R
C H
IT
E
C T
S
/3
/2
JE DUNN + HWA
CLEARWATER, FL 33756
CONSULTING ENGINEER
1765 CARNEGIE AVENUE
Ph: (727) 505-9941
JAMES E. BRADLEY, P.E.
J E B
0' 4' 8' 16' 32'
1/8" = 1'-0"
0' 2' 4' 8' 16'
1/4" = 1'-0"
0' 1' 2'
3/4" = 1'-0"
4'0' 1'
1 1/2" = 1'-0"
2' 2'1'6"6"3"0' 6"
3" = 1'-0"
1'3"
NOT FOR CONSTRUCTION
2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930
TPF TYNDALL -
CONNECTING CORRIDOR
T Y
N D
A L
L A
F B
C O
N N
E C
T
IN
G C
O R
R
ID
O R
M
A G
N O
L
IA
C
IR
C L
E T
Y N
D A
L L
A F
B
F L
A S
I N
D
IC
A T
E D
J .L
.B
W -1
-R
-6
W -1
-D
-6
J A
M E
S E
B
R A
D L E
Y P
.E
J E
D U
N N
S U
B M
IT
T
A L
C
O R
R E
C T
E D
F
IN
A L
J .E
.B
A s i n d ic a te d F
L O
O R
P L A
N
T Y
N D
A L L A
F B
P U
B L
IC
H E
A L T
H B
L D
G
TCC-
A2.0
M
A G
N O
L
IA
C
IR
C L E
T Y
N D
A L L A
F B
F
L
D e s ig n e r
A u th o r
C h e c k e r
W -1
-R
-6
W -1
-D
-6
S y m b o l
D es cr ip ti o n
T ra ck in g N o
A ct io n
D at e
DOOR SCHEDULE
# SIZE DESCRIPTION QTY HEADER JACKS KINGS COMMENTS
2 TRIPLE 2x6 1 2
F
GENERAL NOTES:
1. DOORS ARE INDICATED SWINGING INTO THE CORRIDOR
ARE LABELED ON SHEETS TNA2.0 & TSA2.0 AND ON THE
OVER ALL PLAN TPF 2.0
72"x80" EXT DOOR - STEEL - FLUSH w/20"x30" SAFETY GLASS VIEW PANEL, STEEL FRAME, CLOSER, PANIC HARDWARE, THRESHOLD, WEATHERSTRIPPING
AND REMOVABLE MULLION
1'-2" 5'-0" 2'-6" 5'-0" 41'-8" 8"
12'-5"5'-0"2'-10"7'-2"
60'-0" 62'-0"
5'-0" 1'-2"
CORRIDOR
435.11 SF
V.C.T.
CORRIDOR
449.78 SF
V.C.T.
F F
THESE DOORS ARE LOCATED
IN THE ADJACENT MODULAR
STRUCTURE, TYP.
W.P.
w/P.C.
W.P.
w/P.C.
W.P.
w/P.C.
W.P.
w/P.C.
9'-8" 5'-0" 38'-2" 5'-0"
26'-4"4'-11"12'-4"14'-4"5'-0"29'-8"
DN
DN
4'-2"
39'-8"
25'-0"
PANEL "B"
100 AMP
120/208v, 1Ø
PANEL "A"
100 AMP
120/208v, 1Ø
C A
N O
P Y
A B
O V
E
C A
N O
P Y
A B
O V
E
ROOF DRAIN & OVERFLOW
THRU FLOOR
2x8 WALL THIS SIDE
2x6 WALL THIS SIDE
2x8 WALL THIS SIDE
2x6 WALL THIS SIDE
SUPPLY GRILLE THRU
ENDWALL INTO
CORRIDOR FROM
TPF-SOUTH
SUPPLY GRILLE THRU
ENDWALL INTO
CORRIDOR FROM
TPF-SOUTH
16'-9"
VALID
January 27, 2017
File details come from the government source that posted it.