29_02_TNA1.0_Exterior_Elevations.pdf

PDF 370 KB Posted

Attached to
Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
Solicitation number
W9127S19Q6039
Issued by
Department of the Army Corps of Engineers Engineering District Little Rock

About this file

Part of Attachment I - As-Builts, 29-TPF North Public Health

View the file

Other files for this federal contract opportunity

Other files attached to Tyndall AFB Temporary Modular Medical Facility, newest first.
File Type Posted
49_25__TPFV7.0_RAMP_STEP_AND_PLATFORM_CONNECTION_DETAILS_STAMPED.pdf PDF
1-V1.03_SURVEY_PLAN.pdf PDF
49_23__TCP1.4_Combined_Clinic_TPF_RCP.pdf PDF
1-V1.08_SURVEY_PLAN.pdf PDF
49_21__TFP4.2_Combined_Clinic_TPF_Fire_Alarm_Plan_Phase_2.pdf PDF
49_24__TPF4.0_Overall_Supply_Plumbing_Schematic.pdf PDF
49_24__TPF5.0_Overall_DWV_&_Waste_Schematic.pdf PDF
49_25__TPFV6.0_CANOPY_FOOTING_DETAILS_STAMPED.pdf PDF
55_TQ3.02_-_FFE_JSN_LEGEND.pdf PDF
49_21__TFP2.0_Combined_Clinic_TPF_Life_Safety_Plan.pdf PDF
49_24__TPF1.0_Full_Building_Elevations.pdf PDF
49_23__TCP1.4-PI_Combined_Clinic_TPF_RCP-PHASE_1.pdf PDF
49_21__TFP3.2_Combined_Clinic_TPF_Fire_Suppression_Plan_Phase_2.pdf PDF
49_21__TFP4.1_Combined_Clinic_TPF_Fire_Alarm_Plan_Phase_1.pdf PDF
56_SGT.03_TEMP_SIGNAGE_TPF_PHASE_2.pdf PDF
55_TQ3.01_-_FFE_JSN_LEGEND.pdf PDF
56_SGT.02_TEMP_SIGNAGE_TPF_PHASE_1.pdf PDF
49_22__TLV1.0_Combined_Clinic_TPF_LV_Systems_Notes_&_Details.pdf PDF
55_TQ4.11D_-_FFE_PLAN_-_TPF_PHASE_2,_AREA_D.pdf PDF
49_23__TCP1.5_Combined_Clinic_TPF_RCP.pdf PDF
49_25__TPFV2.0_STANDARD_RAMP_AND_STAIR_DETAILS_STAMPED.pdf PDF
49_24__TPF2.0-PI_Full_Building_Plan-Phase_1.pdf PDF
08_T1.10_-_TELECOM_SITE_PLAN_-_CONSTRUCTION_PHASE.pdf PDF
43_17_TCCE2.0_Illumination_Plan.pdf PDF
29_02_TNA2.1_Interior_Elevations.pdf PDF
Attachment_H_-_TPF_Placement_Area.pdf PDF
36_09_TSA4.0_Egress_Plan.pdf PDF
36_08_TSC1.0_Cover_Sheet.pdf PDF
36_11_TSE1.0_Electrical_Plan.pdf PDF
43_18_TCCM1.0_MECHANICAL_HVAC_PLAN.pdf PDF
08_T6.05-TECHNOLOGY_SITE_RISER_DIAGRAM.pdf PDF
36_13_TSX1.0_Building_Cross_Section.pdf PDF
43_15_TCCC1.0_Cover_Sheet_-_Notes.pdf PDF
28_CS.43_-_DWG_INDEX_PKG_I_VOL_3_OF_4.pdf PDF
29_04_TNE1.1_Electrical_Panel_Schedules.pdf PDF
36_10_TSP2.0_Plumbing_Schematics.pdf PDF
29_02_TNA3.0_Reflective_Ceiling_Plan.pdf PDF
36_14_TSFD1.0_Foundation_Plan_and_Details.pdf PDF
36_11_TSE4.0_MDP_-_One_Line_Diagram.pdf PDF
36_09_TSA3.0-PII_Reflective_Ceiling_Plan.pdf PDF
29_04_TNE1.0_Elec_Plan.pdf PDF
36_12_TSM1.0-PII_Mechanical_HVAC_Plan.pdf PDF
43_16_TCCA2.0_Floor_Plan.pdf PDF
36_10_TSP4.0_Plumbing_Plan_-_DWV_Phase_1.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Response_to_Questions_13Aug19.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Combined_Synopsis_Solicitation_13Aug19.pdf PDF
Attachment_E_-_Installation_Facility_Standards_&_Plans.pdf PDF
Tyndall_TMMF_Statement_of_Work_10Jul19.pdf PDF
Attachment_F_-_Codes_&_Criteria.pdf PDF
Attachment_D_-_DHA_LAN_WLAN_Guides.pdf PDF
Show all 50

Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

54321

B

C

D

E

B A

S E

C

IV

IL

E

N G

IN

E

E R

/D E

P U

T Y

C H

IE

F

E N

G

IN

E E

R

IN

G F

L

IG

H T

C

E P

C H

IE

F

C O

N T

R A

C T

S S

E C

T

IO

N

C E

P M

R E

C O

M M

E N

D E

D

R E

C O

M M

E N

D E

D

A P

P R

O V

E D

R E

V D

A T

E E

N G

IN

E

E R

\D E

S

IG

N E

R

D R

A W

N B

Y

S C

A L

E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

C O

N T

R A

C T

N U

M B

E R

D E

S

IG

N T

E A

M C

E P

M

U S

IN

G

A G

E N

C Y

C H

E C

K E

D B

Y

H O

E F

E R

W Y

S O

C K

I

A R

C H

IT

E

C T

S

/3

/2

JE DUNN + HWA

CLEARWATER, FL 33756

CONSULTING ENGINEER

1765 CARNEGIE AVENUE

Ph: (727) 505-9941

JAMES E. BRADLEY, P.E.

J E B

0' 4' 8' 16' 32'

1/8" = 1'-0"

0' 2' 4' 8' 16'

1/4" = 1'-0"

0' 1' 2'

3/4" = 1'-0"

4'0' 1'

1 1/2" = 1'-0"

2' 2'1'6"6"3"0' 6"

3" = 1'-0"

1'3"

2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930

TPF TYNDALL - NORTH

PUBLIC HEALTH BLDG

S U

B M

IT

T

A L

C O

R R

E C

T E

D F

IN

A

L

J A

M E

S E

B

R A

D L

E Y

P

.E

J .L

.B

J .E

.B

J E

D U

N N

W

-1

-R -6

W

-1

-D -6

A S

I N

D

IC

A T

E D

THIRD PARTY:

& ASSOCIATES

HILBORN, WERNER, CARTER

1627 SOUTH MYRTLE AVE.

CLEARWATER, FLORIDA 33756

E X

T E

R

IO

R E

L E

V A

T

IO

N S

T Y

N D

A L

L A

F B

P U

B L

IC

H

E A

L T

H B

L D

G

TNA1.0

M

A G

N O

L

IA

C

IR

C L

E T

Y N

D A

L L

A F

B

F L

S y m b o l

D es cr ip ti o n T ra ck in g

N o

A ct io n

D at e

GENERAL NOTES:

1. RE. DRAWING SHEETS, TNA 2.0, TSA-2.0 & TCCA-2.0 FOR INTERIOR

AND EXTERIOR FINISHES.

2. RE FLOOR PLANS TNA-2.0 FOR WINDOW TYPES.

3. RE. TCC-X1.0 FOR GUTTER AND ROOF DRAINAGE DETAILS AT

INTERIOR CORRIDOR.

SCALE: 1/4"=1'-0"

RIGHT SIDEWALL ELEVATION

SCALE: 1/4"=1'-0"

REAR ENDWALL ELEVATION

SCALE: 1/4"=1'-0"

FRONT ENDWALL ELEVATION

SCALE: 1/4"=1'-0"

LEFT SIDEWALL ELEVATION

A A1.0

B A1.0

C A1.0

D A1.0

20.50

22.50

19.10

22.50

19.60

22.50

19.10

22.50

20.50

22.50

19.80

22.50

19.60

22.50

A B C D G i KE F H J L N o PM

ABCDGiK EFHJLNoP M

P

A

EPDM RUBBER

ROOFING

5/16 NICHIHA PANELS OVER

APPROVED MOISTURE

5/16 NICHIHA TRIM

5/16 NICHIHA PANELS OVER

APPROVED MOISTURE

EPDM RUBBER

ROOFING

5/16 NICHIHA PANELS OVER

APPROVED MOISTURE

5/16 NICHIHA TRIM

5/16 NICHIHA PANELS OVER

APPROVED MOISTURE

ALUM

DOWNSPOUT,

TYP.

ALUM

GUTTER,

TYP.

ALUM

GUTTER,

TYP.

ALUM

DOWNSPOUT,

TYP.

ALUM

GUTTER,

TYP.

ALUM

DOWNSPOUT,

TYP.

19.80

22.50

30.50

34.00

30.50

34.00

30.50

34.00

30.50

34.00

30.50

34.00

11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8"

11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8"

186'-8"

186'-8"

60'-0"

60'-0"

ALUM

DOWNSPOUT,

TYP.

ALUM

DOWNSPOUT,

TYP.

ALUM GUTTER

ALUM GUTTER

ALUM GUTTER

RE. TCC 1.0 FOR CENTER PORTION

AND THE ENTIRE EAST ELEVATION

RE TPF 1.0 FOR CONTINUATION OF

ELEVATION.

RE. TCC 1.0 FOR CENTER PORTION

AND THE ENTIRE EAST ELEVATION

RE TPF 1.0 FOR CONTINUATION OF

ELEVATION.

FOUNDATION ENCLOSURE (WHEN PROVIDED) MUST HAVE 1 SQUARE FOOT NET VENT

AREA PER 1/150TH OF THE FLOOR AREA, AND AN 18"x24" MINIMUM CRAWLSPACE

ACCESS, SITE INSTALLED BY OTHERS, SUBJECT TO LOCAL JURISDICTION APPROVAL.

MIN. 18" x 24" CRAWL SPACE ACCESS.

ACTUAL LOCATION MAY VARY SHOWN FOR

REFERENCE ONLY

MIN. 8" x 16" SKIRTING VENTS ACTUAL

LOCATION AND QUANTITY MAY VARY

SHOWN FOR REFERENCE ONLY

VALID

January 27, 2017

File details come from the government source that posted it.