Amendment_0001_Instruments-7602948_7602951.pdf

PDF 256 KB Posted

Attached to
PROPOSAL DUE DATE IS AUGUST 29, 2018 Federal contract opportunity
Solicitation number
W9127S18R6022
Issued by
Department of the Army Corps of Engineers Engineering District Little Rock

About this file

Technical information for ProjNet Questions and Answers.

View the file

Other files for this federal contract opportunity

Other files attached to PROPOSAL DUE DATE IS AUGUST 29, 2018, newest first.
File Type Posted
A.07.24_Natick_Amendment_2.pdf PDF
A.07.23_Natick_SOW_Removes_Signage_Reference_Amendment_2.pdf PDF
W9127S18R6022_Amd_0001_Natick_ProjNet_Q&A.pdf PDF
A.07.23_Attachment_1_-_Bid_Schedule_R1_7-24-18.xlsx XLSX spreadsheet
E0930_Locker, Supply, 6 Drawers, Mobile, 29W x 20D_Redacted.pdf PDF
E0078_Redacted.pdf PDF
L6000.docx DOCX document
F0355_Footstool, Straight_Redacted.pdf PDF
F0420_Cabinet, Filing, Lateral, 2 Drawer, 3 Open Shelves.pdf PDF
F0601.docx DOCX document
M1411.docx DOCX document
F2010.docx DOCX document
F0415_Cabinet, Filing, Lateral, Full Height, 5 Drawer_Redacted.pdf PDF
F2000_Basket Wastepaper Rectangular_Redacted.pdf PDF
E0117_Workstation, Straight, Freestanding, 48 W_Redacted.pdf PDF
E0042_Redacted.pdf PDF
F0115_Bookcase, Open, 5 Shelf_Redacted.pdf PDF
M0550 Sampler.docx DOCX document
F0305.docx DOCX document
F0465B_Cabinet, Storage, 2 Door, 5 Shelf, Office_Redacted.pdf PDF
A.07.23_Attachment_5_-_Exterior_Photos_of_Building_30.pdf PDF
L2570.docx DOCX document
M3072_Frame, Infectious Waste Bag w-Lid_Redacted.pdf PDF
M4200.docx DOCX document
R7250 Refrigerator.docx DOCX document
F2020.docx DOCX document
F0206.docx DOCX document
A.07.23_Attachment_4_-_2_of_4_-_Commodity_Specifications.zip ZIP file
T0801_Workbench, Electric, Locker Base_Redacted.pdf PDF
M5027_Redacted.pdf PDF
E0851.docx DOCX document
M4100_Sphygmomanometer, Aneroid, Rail Mounted_Redacted.pdf PDF
A.07.23_Attachment_3_-_Reuse_Disposal_List.zip ZIP file
F3050C.pdf PDF
M0507_Redacted.pdf PDF
M5025.docx DOCX document
A.07.23_Attachment_2_-_Past_Performance_Questionnaire.docx DOCX document
M8810_Redacted.pdf PDF
M4116_Monitor, Vital Signs, Rail Mounted_Redacted.pdf PDF
M1410.docx DOCX document
A5076.docx DOCX document
M0040_Redacted.pdf PDF
M3070.pdf PDF
F2310_Rack, Pamphlet, Wall Mounted_Redacted.pdf PDF
F0275.docx DOCX document
U0004 Security System_Redacted.pdf PDF
F0505_Bucket, Mop, With Wringer, 26 Quart_Redacted.pdf PDF
A.07.23_Attachment_6_-_Plans.pdf PDF
A.07.23_Attachment_1_-_Bid_Schedule.xlsx XLSX spreadsheet
A.07.23_Attachment_4_-_Commodity_Specifications.zip ZIP file
Show all 50

PROPOSAL DUE DATE IS AUGUST 29, 2018 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Measuring principle: UV-Absorption

Wavelength:

UV source:

Stabilization method:

Measuring ranges:

Sensitivity:

Response time (99% signal):

Alarm:

Status alarms:

Measurement Display:

Data Logger:

Signal outputs:

Power Supply:

Weight:

L6000 Mercury Instruments Mercury Tracker 3000 IP

Portable Mercury Vapor Analyzer

Real Time, Continuous Reading 3 mercury measuring ranges 0-100 / 0-1000 / 0-2000 µg/m³ Sensitivity: 0.1 µg/m³ Data logger integrated No need for constant calibration No detector regeneration required No detector saturation Issues Lightweight Ergonomic shoulder strap dismountable probe Integrated battery for 6 hours operation Shock proof and corrosion resistant

Mercury Tracker 3000 IP Technical Specification

253,7 nm

Electrode less low-pressure mercury lamp (EDL) reference beam feedback lamp control

0.1 to 100 µg/m³ 0 to1000 µg/m³ 0 to 2000 µg/m³

0.1 µg/m³ (0.01 ppb)

1 second

3 levels programmable measuring cell soiled, battery state, UV source exhausted

Graphical LC display with background illumination

Integrated logger as standard, capacity 10000 readings

4...20 mA for recorder; USB / RS 232 for PC or printer built-in rechargeable NiMH batteries, external 12 V DC sources, 110 ... 240 V/(50/60 Hz) with included power supply approx. 5 kg (including batteries)

As a leading supplier of high precision analytical equipment, we strive at all times to offer top quality solutions. Our products are manufactured according to the ISO

9001 quality regulations.

M0550

Sampler, Air Particulate (Pollen)

AEROBIOLOGY GRIPST-2009

TThis model is designed for long-term aeroallergen monitoring projects. The compact sampler casing is constructed from galvanized steel, with a tightly-closing hatch for easy access to the sampler internals. All exterior components are rated NEMA-4 or better. This model includes a super-heavy-duty maintenance-free Maxon motor for extended life, and a voltage regulator that provides stable rotation speed for any >12VDC power source and the ability to adjust and calibrate rotation speed to suit the needs of the monitoring project. This sampler incorporates a solid-state relay timer that allows the sampler to be set to any desired duty cycle, and is equipped with a 1.5" long sampling head mounting post, C&C machined, to reduce air turbulence.

Specifications:

Dimensions: 16cm x 18cm x 16cm (including post) Weight:

2.5 kg

Input Power: DC 12V to 30V, 300mA Power Plug: Banana jacks, screw clamp

Sampler comes with an auto-retracting sampling head for "Type-I" sampling rods, and a package of 100 "Type-I" rods. Samplers are shipped calibrated to 2400RPM, and set to a 10% duty cycle (one minute on, nine minutes off) when applicable.

Power cord must be purchased separately AND MUST BE

INCLUDED.

L6000

Type 2250-S

Hand-held analyzer

Type 2250-S is a class 1 sound level meter (SLM) that comes with the microphone, preamplifier and basic applications you need to get started with accurate environmental, occupational and industrial measurement tasks.

It is rugged enough for the field yet precise enough to go straight to the lab.

Type 2250-S can be expanded with specialized applications such as building acoustics, FFT analysis, tone assessment and noise and vibration.

USE SCENARIOS

• General-purpose class 1 sound measurements to the latest international standards

• Occupational Health and Safety (OHS) noise assessments

• Environmental noise assessment and logging

• Product development and quality control

• Sound and vibration FFT analysis

• Building acoustics, loudness and noise rating measurements https://www.bksv.com/en m4ecdkac Line m4ecdkac Text Box T8040

• Tone assessment using 1/3-octave and FFT methods

• Infrasound (G-weighting) measurements according to ISO 7196:1995 and ANSI S1.42–2001 (R2011)

CHARACTERISTICS

The basic applications package includes:

• Sound Level Meter Software BZ-7222

• Frequency Analysis Software BZ-7223

• Tone Assessment Software BZ-7231

• Noise Monitoring Software BZ-7232

The built-in flexibility of these instruments allows you to add applications and other hardware to expand their capabilities beyond the range of the standard SLM, from OHS to building acoustics and reverberation time to FFT analysis and vibration and low-frequency analysis, even to sound power and intensity and noise source identification applications.

> See the full range of optional application software

ADDITIONAL CAPABILITIES - VIBRATION METER

Type 2250-S can also be used as a vibration meter by adding Enhanced Vibration and Low Frequency Option BZ-7234 and an appropriate accelerometer.

This allows you to do quality testing and inspection, machinery analysis and troubleshooting, building vibration measurements, low-frequency building vibration measurements according to ISO 8041:2005 and DIN standards, and machine health analysis after maintenance, repair and overhaul (MRO).

https://www.bksv.com/en/products/sound-and-vibration-meters/sound-level-meter-applications/bz-7222-sound-level-meter-software https://www.bksv.com/en/products/sound-and-vibration-meters/sound-level-meter-applications/bz-7222-sound-level-meter-software https://www.bksv.com/en/products/sound-and-vibration-meters/sound-level-meter-applications/bz-7222-sound-level-meter-software https://www.bksv.com/en/products/sound-and-vibration-meters/sound-level-meter-applications/bz-7222-sound-level-meter-software https://www.bksv.com/en/products/sound-and-vibration-meters/sound-level-meter-applications/bz-7223-1-3-and-1-1-octave-frequency-analysis https://www.bksv.com/en/products/sound-and-vibration-meters/sound-level-meter-applications/bz-7231-tone-assessment https://www.bksv.com/Components/Framework/ErrorPages/Presentation/404.aspx?item=web%3a%7bA1526426-1D2D-454D-95F7-E0D54259AB56%7d%40en https://www.bksv.com/en/products/sound-and-vibration-meters/sound-level-meter-applications

T8040A

Oscilloscope with Accessories

190M-4 Medical ScopeMeter Portable Oscilloscope

L6000 Mercury Vapor Analyser_KC
L6000
Mercury Instruments
Mercury Tracker 3000 IP
Portable Mercury Vapor Analyzer
Mercury Tracker 3000 IP Technical Specification
M0550 Air Sampler_KC
M0550
Sampler, Air Particulate (Pollen)
AEROBIOLOGY GRIPST-2009
T8040_KC
USE SCENARIOS
CHARACTERISTICS
ADDITIONAL CAPABILITIES - VIBRATION METER

T8040A Pollen Sampler_KC

File details come from the government source that posted it.