A.03 Plans - Drawings - BDP1.142_E-108XXX.pdf

PDF 241 KB Posted

Attached to
BRADFORD ISLAND SERVICE BUILDING PRQ SWITCHGEAR UPGRADE
Solicitation number
W9127N24R0012
Issued by

About this file

This document appears to be a set of plans and drawings related to a federal contract opportunity for the BRADFORD ISLAND SERVICE BUILDING PRQ SWITCHGEAR UPGRADE project. The project objective is to replace the existing 480V switchboard and station service transformers located in the Bradford Island Service Building and relocate the new transformer disconnect switches and 1,500 kVA transformers directly outside the existing electrical room. The new 480V switchgear and associated equipment will be housed in the existing electrical room, and an exhaust fan or AC system will be provided to cool the electrical room. Additional requirements include providing panic hardware for the electrical room doors, fire stopping, fire extinguishers, and emergency lighting. The solicitation number is W9127N24R0012 and the contracting agency is the Department of the Army Corps of Engineers Engineering District Portland.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

7 1/2 "

1'-3 1/2 "

GENERAL NOTES

REFERENCE DRAWINGS

FIBER

CABLE TRAY

BUILDING

TO SERVICE

CABLE VAULT CV4

BDG-6-7-9 13.8KV FEEDER SECTIONS AND DETAILS

CABLE VAULT CV4

BDD-6-2-25 SPILLWAY SOUTH CONTROL TOWER INSTALLATION

85.25

BDD-6-23 SPILLWAY SOUTH CONTROL TOWER INSTALLATION EL.

MDQ1

DS1DSCR1

FL3

ATS.MD1

PLC.MD1

HVCV11 EL. 49

BANK DOWN TO

VERTICAL DUCT

COVER SIDES & BOTTOM.

4" MIN. CONCRETE.

SPARE

CU CABLE

1 #2/0 BARE

CABLE TRAY

HVCV11 EL. 49

BANK DOWN TO

VERTICAL DUCT

IDENTIFIERS (NO CONDUITS INSIDE OF CV4).

EXCEPT FOR CV4 PLANS AND SECTIONS THAT SHOW CABLE

4. IDENTIFIERS SHOWN ON DRAWING ARE CONDUIT IDENTIFIERS

VAULT.

A MIX 13.8KV, 480V, AND COMMUNICATIONS CABLES IN THE SAME

CONDUITS, CABLE TRAY AND EQUIPMENT SHOWN. CV4 CONTAINS

3. FOR CLARITY OF DRAWING, NOT ALL EXISTING CABLES,

CONDUITS BEING RE-USED VS PROVIDED AS NEW.

TO CONDUIT AND CABLE SCHEDULE ON E-701 FOR LIST OF

EXISTING TO BE RE-USED UNLESS NOTED OTHERWISE. REFER

INSTALLED IN EXISTING CONDUIT. MOST CONDUITS ARE

2. CONDUITS SHOWN RED INDICATE NEW CONDUCTORS

1. ITEMS SHOWN IN RED ARE NEW OR MODIFIED.

PHONE

Q08

J02

J01

J02 J01

10CONDUIT DOWN

Q08

J02

J01

Q08

Q08

J02

J01

OPTIONAL CLIN #1 KEYED NOTESC#

PHONE CABLE TO REMAIN.

BANK INSTEAD OF EXISTING DUCT BANK. EXISTING FIBER AND

#1 IS EXECUTED. NEW CABLES TO BE INSTALLED IN NEW DUCT

C3. EXISTING DUCT BANK TO BE ABANDONED IF OPTIONAL CLIN

DETAIL A3, SHEET E-502.

C2. PROVIDE NEW CONCRETE ENCASED DUCT BANK. REFER TO

PENETRATIONS WITH COR.

ENTERING CV4. COORDINATE EXACT LOCATION OF

C1. PROVIDE NEW PENETRATIONS FOR NEW CONDUITS

C2C2

C1C1

C3C3

D

C

A

B

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

A M

E

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

C O

N T

R A

C T

N O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

D R

A W

N B

Y

C H

E C

K E

D B

Y

/0

/2

A D

V E

R T

IS

E

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

P O

R T

L A

N D

O

R E

G O

N

P O

R T

L A

N D

D

IS

T R

IC

T

/2

/2

R E

V

IS

E D

D U

C T

B A

N K

R E

Q U

IR

E

M E

N T

S

A N

S I

E

G E

C D

S E

G

S G

R

IF

F

IN

P

.E

G E

C D

E B

R

E-108

:1

P R

Q S

W

IT

C H

G E

A R

U P

G R

A D

E B

R A

D F

O R

D I

S L

A N

D W

N

R

B O

N N

E V

IL

L

E L

O C

K A

N D

D A

M

W F

O R

T U

N Y

P

E

0 2' 4'1'

1' 2'0 6"0 2' 4'1'

0 2' 4'1'

B D

P .1

E

-1 X

X X

.D G

N A

N D

C V

S

E C

T

IO

N S

S O

U T

H T

O W

E R

E L

.2

P

L A

N C

V P

L A

N

IN

S

T A

L L

A T

IO

N

A5

INSTALLATION - DUCT BANK SECTION

" = 1'-0"2

SCALE 1

D3

INSTALLATION - CV4 SECTION

SCALE 1/2" = 1'-0"

B5

INSTALLATION - CV4 SECTION

SCALE 1/2" = 1'-0"

A1

INSTALLATION - SOUTH TOWER EL. 85.25 AND CV4 PLAN EL. 92.0

SCALE 1/2" = 1'-0"

D3

A5

B5

PORTLAND DISTRICT