AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this amendment is to update the solicitation number on the advertise draw ings. All other terms and conditions remain the same.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 2
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 23-Oct-2019
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W9127N20B0002
X 9B. DATED (SEE ITEM 11)
15-Oct-2019
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
23-Oct-2019
CODE
USACE PORTLAND DISTRICT
333 SW 1ST AVE
PORTLAND OR 97204-3440
W9127N 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W9127N20B0002
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
(End of Summary of Changes)
Portland District q of Engineers
US Army Corps
DATE:
DISTRICT COMMANDER
COLONEL, CORPS OF ENGINEERS
AARON L. DORF
DIRECTOR, HYDROELECTRIC DESIGN CENTER
STEVEN R. MILES, P.E.
EMPLOYMENT AS REQUIRED BY ER 1110-1-8152.
PROJECT DOCUMENTS WITHIN THE SCOPE OF THEIR
DESIGNATIONS OF INDIVIDUALS APPEAR ON THESE
THE INITIALS OR SIGNATURES AND REGISTRATION
DISTRICT OF THE U.S. ARMY CORPS OF ENGINEERS.
THIS PROJECT WAS DESIGNED BY THE PORTLAND
CHIEF, DESIGN BRANCH
MARK J. SAWKA, P.E.
FIRE PROTECTION
OIL STORAGE ROOMS
FIRST AND SECOND POWERHOUSES
BONNEVILLE LOCK AND DAM
JULY 12, 2019
CHIEF, ENGINEERING & CONSTRUCTION DIVISION
ELIZABETH R. WELLS, P.E.
W9127N20B0002SOLICITATION NUMBER:
/1
/2
INTERSTATE
INTERSTATE
INTERSTATE
W I L
L A
M E
T T
E
REV
I
R
COLUMBIA RIVER
LONGVIEW
PORTLAND
VANCOUVER
SALEM
WASHINGTON
OREGON
HOOD RIVER
THE DALLES
L O
C K A
N D D
A M
JO
H
N D
A Y
L O
C K A
N D D
A M
T H
E D
A L L E S
L O
C K A
N D D
A M
B O
N N
E V
IL
L E
RUNGE
BRIDGE
KNOLL
-16
X
X X X X X X X X
City Well
S h a d y
O a k
L n
L o o k -I n n e
L a k e s id e
W a y
S p r i n g s
R o a d
X X X X
X X
X X
X X
X X
-16
X
X
X
X
X
X
X
X X X X X X X
X
X
X X
X
X X X X X X
X
X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X top o f w all el ev
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
C e l i l o
S u n
T i l l i c u m
H a l
C h a k o r .
C a s c a d e
D r i v e
G r e e n l e a f
-16
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
B o t u n c h
A c c e a d
DRAIN
CONCRETE
P
ATCH
WATER
and Spillway
Bonneville Dam
INTERSTATE
INTERSTATE
PROJECT SITE MAP
SCALE: 1" = 500'
DISTRICT BOUNDARY MAP
LOCAL VICINITY MAP
PROJECT PHOTO
DRAWING PLOT SIZE: ANSI D
D
C
A
B
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R
/2
/2
BORDER VERSION UPDATE [09-2012]
G1001SHEET NAME:g2hdcgp9 MSTforACAD-V8i-IntroBY USERNAME:DATE AND TIME PLOTTED: 10/21/2019 11:31:23 AM of Engineers
US Army Corps
A D
V E
R T
IS
E
MILES
0 10 20 30 40 5010
LOCATION
PROJECT WORK
BONNEVILLE
NORTH
SITE
HISTORIC
NATIONAL
CASCADE
FORT
BYPASS OUTFALLS
JUVENILE FISH
(4
M I)
PO
RTLA
N D
I-84 EXIT #40
ISLAND
ROBINS
RAILROAD
UNION PACIFIC
POWERHOUSE
FIRST
ISLAND
BRADFORD
DAM
SPILLWAY
POWERHOUSE
SECOND
ISLAND
CASCADES
OREGON
WASHINGTON
W A S H
IN
G T
O N
O R E G
O N
M
ULT
N O
M
AH
C
O
UN
TY
COLUMBIA RIVER
BURLI
NGTO
N
NO
RTHER
N
RAI
LR
O
AD
SK
AM
AN
IA
C
O
UN
TY
LOCATION
PROJECT WORK
0500' 500'
LOCATION
PROJECT
LOCATION
PROJECT
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
P O
R T
L A
N D D
IS
T R
IC
T
N
S I F
O J E
C T P
H O
T O
P R
O J E
C T S
IT
E M
A P
S A
N D
D
IS
T R
IC
T B
O U
N D
A R
Y L
O C
A L V
IC
IN
IT
Y
G1001
:1
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S .A
R M
Y C
O R
P S O
F E
N G
IN
E E
S
R T
L A
N D O
R E
G
B
N N
E V
IL
L E L
O C
K A
N D D
A M
F
IR
E P
R O
T E
C T
IO
N
B D
P .1
G .d g n
B
B E
N S
O N
S L
O R
E N
Z B
B E
N S
O N
J
IM
B
R U
N O
T
W
N
B
F
IR
S T A
N D S
E C
O N
D P
O W
E R
H O
U S
E S
O
IL
S
T O
R A
G E R
O O
M S
FLOW
PORTLAND DISTRICT
/2
NOTES:
1. SEE SHEET G2002 FOR SECOND POWERHOUSE DRAWING INDEXES.
DRAWING PLOT SIZE: ANSI D
D
C
A
B
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R
/2
/2
BORDER VERSION UPDATE [09-2012]
G-002SHEET NAME:g2hdcgp9 MSTforACAD-V8i-IntroBY USERNAME:DATE AND TIME PLOTTED: 10/21/2019 11:31:29 AM of Engineers
US Army Corps
A D
V E
R T
IS
E U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D D
IS
T R
S
G1002
N N
E V
IL
L E L
O C
K A
N D D
A M
F
IR
E P
R O
T E
C T
IO
N
B
B E
N S
O N
S L
O R
E N
Z
J
IM
B
R U
N O
T
F
IR
S T P
O W
E R
H O
U S
E
O
IL
S
T O
R A
G E R
O O
M
G E
N E
R A
L D
R A
W
IN
G
IN
D
E X
B D
P .1
G .d g n
P O
R T
L A
N D
O R
E G
O N
B
B E
N S
O N
W
N
B o le F ir e P r o t e c t io n W e s t s t S tr e e t
O la th e
K S
.8
.8 o ff ic
.8
.8 f a x w w w .p o o le fi re .c o m
PLAN NORTH
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
PLAN NORTH
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
2'1' 4'0
SCALE: 3/4" = 1'-0"
C O
P T
P T
OIL STORAGE
ROOM
BN1
20'
EL. 37.0
37' - 0"
PS
SO
PS
SO FSCP
FSCP
CO
SO
PT
PS
DR
A
2 3 4 5 6
US Army Corps of Engineers ®
SHEET
IDENTIFICATION
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C K
D B
Y
A N
S I F
D A
T E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
D A
T E
D E
S
IG
N F
IL
E
DATE AND TIME PLOTTED::
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
P L
O T S
C A
L E
P L
O T D
A T
E
F
IL
E N
A M
E
F
IL
E N
U M
B E
R
BY USERNAME: SHEET NAME:
B
C
D
E
DRAWING PLOT SIZE: 40x28 ANSI F SBRINKMEYER
PORTLAND DISTRICT
1/17/2019 8:40:11 AM
FD1101
C O
E
L E
C T
R
IC
A L D
E M
O L
IT
IO
N P
L A
N B
N
B O
N N
E V
IL
L E L
O C
K A
N D D
A M
P O
R T
L A
N D D
IS
T R
IC
T
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
J P
A H
L O
W
J P
A H
L O
W A P
O O
L E
/1
/2
W
N
B
O
IL
S
T O
R A
G E R
O O
M
F
IR
E P
R O
T E
C T
IO
N
/1
/2
B D
P .1
F
D .D
G N
CO2 ELECTRICAL DEMOLITION PLAN - BN1
F
IR
S T P
O W
E R
H O
U S
E
B D
P .1
F
D .D
G N
SCALE: 1/4" = 1'-0"
A1
BN1 OIL STORAGE ROOM ELECTRICAL DEMOLITION PLAN - EL +10.00
SCALE: 3/4" = 1'-0"
A3
BN1 ROUTING VALVE DEMOLITION SECTION - ELECTRICAL - EL +37.00
SCALE: 1/4" = 1'-0"
C3
BN1 CYLINDERS AND ROUTING VALVES DEMOLITION PLAN - ELECTRICAL - EL +37.00
A D
V E
R T
IS
E
T O O
IL
S
T O
R A
G E R
O O
M
T O G
E N
T O G
E N
F
R O
M C
Y L
IN
D E
R S
T O G
E N
T O G
E N
CAP AT THE "T"
C4
FD1103
C L P
IE
R
C L U
N
IT
INITIAL DISCHARGE CYLINDERS
(48 TOTAL, 24 ON EACH SIDE)
EXTENDED DISCHARGE CYLINDERS
(30 TOTAL, 15 ON EACH SIDE)
ROUTING VALVES
CAP PIPING AT
CONNECTION TO HEADER
AND DEMO BACK TO OIL
STORAGE ROOM
A3
FD1101
EXISTING FSCP TO REMAIN.
DEMOLISH ALL OIL STORAGE ROOM
CO2 SYSTEM CONTROLS AND
WIRING, APPROXIMATELY 450 FEET
TO OIL STORAGE ROOM.
1.
2.
3.
4.
5.
6.
7.
8.
DEMOLISH ALL CO2 PIPING, NOZZLES, RELEASING
EQUIPMENT, CONDUIT, AND ASSOCIATED APPURTENANCES
INCLUDING HANGARS AND BRACING.
DEMOLISH ALL EXISTING CO2 NOTIFICATION APPLIANCES.
DEMOLISH ALL EXISTING HEAT DETECTORS.
DEMOLISH ROUTING VALVES, MANUAL RELEASE STATIONS,
AND RELATED APPURTENANCES.
DEMOLISH ALL ASSOCIATED EQUIPMENT AND WIRING,
INCLUDING EXPOSED CONDUIT NOT TO BE REUSED.
REMAINING ANCHOR BOLTS ARE TO BE GROUND FLUSH
AND GROUTED OVER TO PREVENT HAZARD AND
CORROSION ON ANY EQUIPMENT.
EXISTING CO2 CYLINDERS AND FIRING HEADS MUST BE
TURNED OVER TO PLANT PERSONNEL AND REMAIN THE
PROPERTY OF THE GOVERNMENT.
USACE PLANT PERSONNEL WILL DISCONNECT WIRES IN
EXISTING FSCP ON EL 37 PRIOR TO DEMOLITION.
NOTES:
DEMO FIRE ALARM DEVICE LEGEND
SYMBOL DESCRIPTION
FIRE SUPPRESSION CONTROL PANEL
CO� MANUAL RELEASE STATION
ELECTRIC DISCHARGE CONTROL DEVICE
PRESSURE TRIP
DISCHARGE PRESSURE SWITCH
DOOR RELEASE
HEAT DETECTOR
SYMBOL DESCRIPTION
CO� DISCHARGE NOZZLE
CO� DISCHARGE PIPING
DEMO FIRE SUPPRESSION EQUIPMENT
LEGEND
HATCHING LEGEND
EXISTING CONCRETE WALL
o le F ir e P r o t e c t io n W e s t s t S tr e e t
O la th e
K S
.8
.8 o ff
.8
.8 f a x w w w .p o o le fi re .c o m
PLAN NORTH
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
PLAN NORTH
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
2'1' 4'0
SCALE: 3/4" = 1'-0"
PT
PT
OIL STORAGE
ROOM
BN1
20'
40'
EL. 37.0
37' - 0"
FSCP
CO
SO
PT
PS
DR
A
2 3 4 5 6
US Army Corps of Engineers ®
SHEET
IDENTIFICATION
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C K
D B
Y
A N
S I F
D A
T E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
D A
T E
D E
S
IG
N F
IL
E
DATE AND TIME PLOTTED::
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
P L
O T S
C A
L E
P L
O T D
A T
E
F
IL
E N
A M
E
F
IL
E N
U M
B E
R
BY USERNAME: SHEET NAME:
B
C
D
E
DRAWING PLOT SIZE: 40x28 ANSI F SBRINKMEYER
PORTLAND DISTRICT
1/17/2019 8:40:14 AM
FD1103
C O
M
E C
H A
N
IC
A L D
E M
O L
IT
IO
N P
L A
N B
N
B O
N N
E V
IL
L E L
O C
K A
N D D
A M
P O
R T
L A
N D D
IS
T R
IC
T
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
J P
A H
L O
W
J P
A H
L O
W A P
O O
L E
W
N
B
O
IL
S
T O
R A
G E R
O O
M
F
IR
E P
R O
T E
C T
IO
N
/1
/2
B D
P .1
F
D .D
G N
CO2 MECHANICAL DEMOLITION PLAN - BN1
F
IR
S T P
O W
E R
H O
U S
E
B D
P .1
F
D .D
G N
SCALE: 1/4" = 1'-0"
A1
BN1 OIL STORAGE ROOM MECHANICAL DEMOLITION PLAN - EL +10.00
SCALE: 1/4" = 1'-0"
A4
BN1 CYLINDERS AND ROUTING VALVES - MECHANICAL - EL +37.00
SCALE: 3/4" = 1'-0"
C4
BN1 ROUTING VALVE SECTION - MECHANICAL - EL +37.00 A
D
V E
R T
IS
E
/1
/2
CONTINUE PIPING
DEMO TO ROUTING
VALVES AT EL. 37.0
NEAR UNIT #2.
C L P
IE
R
C L U
N
IT
INITIAL DISCHARGE CYLINDERS EXTENDED DISCHARGE CYLINDERS
ROUTING VALVES
C4
FD1103
CAP PIPING AT CONNECTION
TO HEADER AND DEMO BACK
TO OIL STORAGE ROOM
PIPE CONTINUES
DOWN TO OIL
STORAGE ROOM
A3
FD1101
T O O
IL
S
T O
R A
G E R
O O
M
T O G
E N
T O G
E N
F
R O
M C
Y L
IN
D E
R S
T O G
E N
T O G
E N
CAP AT THE "T"
DEMO FIRE ALARM DEVICE LEGEND
SYMBOL DESCRIPTION
FIRE SUPPRESSION CONTROL PANEL
CO� MANUAL RELEASE STATION
ELECTRIC DISCHARGE CONTROL DEVICE
PRESSURE TRIP
DISCHARGE PRESSURE SWITCH
DOOR RELEASE
HEAT DETECTOR
SYMBOL DESCRIPTION
CO� DISCHARGE NOZZLE
CO� DISCHARGE PIPING
DEMO FIRE SUPPRESSION EQUIPMENT
LEGEND
o le F ir e P r o t e c t io n W e s t s t S tr e e t
O la th e
K S
.8
.8 o ff
.8
.8 f a x w w w .p o o le fi re .c o m
PLAN NORTH
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
OIL STORAGE
ROOM
BN1
20'
PT
A
2 3 4 5 6
US Army Corps of Engineers ®
SHEET
IDENTIFICATION
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C K
D B
Y
A N
S I F
D A
T E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
D A
T E
D E
S
IG
N F
IL
E
DATE AND TIME PLOTTED::
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
P L
O T S
C A
L E
P L
O T D
A T
E
F
IL
E N
A M
E
F
IL
E N
U M
B E
R
BY USERNAME: SHEET NAME:
B
C
D
E
DRAWING PLOT SIZE: 40x28 ANSI F SBRINKMEYER
PORTLAND DISTRICT
1/17/2019 8:39:39 AM
F1101
B N
O
IL
S
T O
R A
G E R
O O
M F
IR
E B
A R
R
IE
R
IM
P
R O
V E
M E
N T S P
L A
N E
L
.0
B O
N N
E V
IL
L E L
O C
K A
N D D
A M
P O
R T
L A
N D D
IS
T R
IC
T
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
J P
A H
L O
W
J P
A H
L O
W A P
O O
L E
/1
/2
W
N
B
O
IL
S
T O
R A
G E R
O O
M
F
IR
E P
R O
T E
C T
IO
N
/1
/2
B D
P .1
F
.D
G N
BN1 OIL STORAGE ROOM FIRE BARRIER IMPROVEMENTS PLAN - EL +10.00
F
IR
S T P
O W
E R
H O
U S
E
B D
P .1
F
.D
G N
SCALE: 1/4" = 1'-0"
A3
BN1 OIL STORAGE ROOM FIRE BARRIER IMPROVEMENTS PLAN - EL +10.00
SCALE: NTS
D1
BN1 EXISTING FIRE DOOR TO BE REMOVED
A D
V E
R T
IS
E
PIPE PENETRATION
PIPE PENETRATION
PIPE PENETRATION
PIPE PENETRATION
PIPE PENETRATION
PIPE PENETRATION
(2) PIPE PENETRATIONS
(9) PIPE PENETRATIONS
NEW ELECTRONICALLY
ACTUATED FIRE DAMPER
OF EXHAUST SYSTEM
INSTALL NEW 90
MINUTE FIRE
DOOR ASSEMBLY
(3'X7'2")
REMOVE EXISTING
ROLLING FIRE
DOOR (DETAIL D1)
ELEVATOR
HATCH
ELEVATOR
HATCH
UTILITY
HATCH
8,000 GALLON
5,000 GALLON
5,000 GALLON
2-HOUR FIRE ENCLOSURE
HATCH LEGEND
EXISTING CONCRETE WALL
1.
2.
3.
4.
EXISTING DOOR ASSEMBLY TO BE REMOVED AND
REPLACED WITH NEW FIRE DOOR ASSEMBLY WITH
ELECTRIC RELEASE.
SEAL ALL NEW AND EXISTING PENETRATIONS WITH A UL
LISTED FIRESTOPPING SYSTEM ASSEMBLY SUITBALE FOR
THE RATING OF THE WALL/CEILING ASSEMBLY IN WHICH
THE PENETRATION OCCURS.
PER NFPA 850, SECTION 5.1.1.4 OIL STORAGE AND OIL
PURIFICATION ROOMS MUST BE A MINIMUM OF 2 HOUR FIRE
RATED, INCLUDING 90 MINUTE FIRE DOOR.
CONTRACTOR MUST FIELD VERIFY DOORS.
NOTES:
o le F ir e P r o t e c t io n W e s t s t S tr e e t
O la th e
K S
.8
.8 o ff
.8
.8 f a x w w w .p o o le fi re .c o m
FSCP
TVSS
DACT
KS
SO
CACA
CA
B
CA
A
CA CA PS AOM AOM AOM AIM CT CT CT
DR
AOMs AOM
AIM
AOM
FACP
CA
CA
KS
SO
PS
CA
LP
DR
CM
FSCP
CO
SO
PT
FSCP
TVSS
DACT
PT
CA
A
CA
B
A
CA
B
CA
PS
DR
FSCP
CT
J s
DM
A
2 3 4 5 6
US Army Corps of Engineers ®
SHEET
IDENTIFICATION
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C K
D B
Y
A N
S I F
D A
T E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
D A
T E
D E
S
IG
N F
IL
E
DATE AND TIME PLOTTED::
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
P L
O T S
C A
L E
P L
O T D
A T
E
F
IL
E N
A M
E
F
IL
E N
U M
B E
R
BY USERNAME: SHEET NAME:
B
C
D
E
DRAWING PLOT SIZE: 40x28 ANSI F SBRINKMEYER
PORTLAND DISTRICT
1/17/2019 8:39:46 AM
FA1001
F
IR
E A
L A
R M G
E N
E R
A L N
O T
E S
D
IA
G R
A M
S
A N
D L
E G
E N
D B
N
B O
N N
E V
IL
L E L
O C
K A
N D D
A M
P O
R T
L A
N D D
IS
T R
IC
T
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
J P
A H
L O
W
J P
A H
L O
W A P
O O
L E
W
N
B
O
IL
S
T O
R A
G E R
O O
M
F
IR
E P
R O
T E
C T
IO
N
/1
/2
B D
P .1
F
A .D
G N
FIRE ALARM GENERAL NOTES, DIAGRAMS, AND LEGEND - BN1
F
IR
S T P
O W
E R
H O
U S
E
B D
P .1
F
A .D
G N
SCALE: NTS
A1
TYPICAL CLEAN AGENT SYSTEM RISER DIAGRAM - BN1
SCALE: NTS
A4
CLEAN AGENT INPUT/OUTPUT MATRIX - BN1
A D
V E
R T
IS
E
/1
/2
1.
2.
3.
4.
5.
ALL ITEMS ARE NEW UNLESS SPECIFICALLY IDENTIFIED AS
EXISTING.
CRITERIA AND STANDARDS:
NFPA 70, 2017 EDITION
NFPA 72, 2016 EDITION
NFPA 90A, 2018 EDITION
NFPA 2001, 2018 EDITION
THE CONTRACTOR MUST CAREFULLY REVIEW APPLICABLE
CRITERIA AND STANDARDS, THESE DRAWINGS, AND THE
PROJECT SPECIFICATIONS FOR IMPORTANT
QUALIFICATION, DEFINITION, SUBMITTAL, PRODUCT
INSTALLATION, AND TESTING REQUIREMENTS.
PROVIDE SYNCHRONIZATION OF VISUAL NOTIFICATION
APPLIANCE CIRCUITS WHERE MORE THAN TWO DEVICES
ARE IN ANY FIELD OF VIEW.
DRAWINGS ARE DIAGRAMMATIC, INTENDED TO CONVEY
THE SCOPE OF WORK AND GENERAL ARRANGEMENTS OF
THE SYSTEM. COORDINATE THE SYSTEM LAYOUT WITH ALL
OTHER DISCIPLINES.
NOTES:
D A
M P
E
V
A C S
H U
T D
O W
N
M O
T O
R S
H U
N T T
R
IP
20 AMP 120V
PREFERRED
A L
A
M
O U
B
U
P E
R V
IS
O
POINT OF CONNECTION FOR
EXISTING FIRE ALARM
INTERFACE WITHIN 25 FEET
OF NEW FSCP
H O
IS
T S
H U
T D
O W
N
NEW FIRE ALARM DEVICE LEGEND
SYMBOL DESCRIPTION
SYMBOL MODIFIERS
CEILING MOUNTED
CANDELA RATING
WATT TAP
C ncd nW
ADDRESSABLE INPUT MODULE
ADDRESSABLE OUTPUT MODULE
FIRE ALARM CONTROL PANEL
CLEAN AGENT MANUAL RELEASE STATION
CLEAN AGENT ABORT STATION
KEYED MAINTENANCE SWITCH
ELECTRIC DISCHARGE CONTROL DEVICE
DISCHARGE PRESSURE SWITCH
CLEAN AGENT MULTI-TONE SPEAKER/CLEAR
STROBE
WALL MOUNT CLEAN AGENT PRE-DISCHARGE
STROBE - BLUE
LOW PRESSURE SWITCH
DOOR RELEASE
CONTROL MODULE
DEMO FIRE ALARM DEVICE LEGEND
SYMBOL DESCRIPTION
FIRE SUPPRESSION CONTROL PANEL
CO� MANUAL RELEASE STATION
ELECTRIC DISCHARGE CONTROL DEVICE
PRESSURE TRIP
FIRE SUPPRESSION CONTROL PANEL
TRANSIENT VOLTAGE SURGE SUPPRESSOR
DIGITAL ALARM COMMUNICATOR TRANSMITTER
PRESSURE TRIP SWITCH
HEAT DETECTOR
WALL MOUNT CLEAN AGENT TROUBLE
STROBE - AMBER
CEILING MOUNT CLEAN AGENT PRE-DISCHARGE
STROBE - BLUE
CEILING MOUNT CLEAN AGENT TROUBLE
STROBE - AMBER
DISCHARGE PRESSURE SWITCH
DOOR RELEASE
HEAT DETECTOR
HATCHING LEGEND
EXISTING CONCRETE WALL
EXISTING FIRE SUPPRESSION CONTROL PANEL
DISCRETE OUPUT - DRY CONTACT
JUNCTION BOX
SMOKE DETECTOR
FIRE ALARM DEVICE ADDRESS#XX#
DAMPER MODULE
NOTE: THIS MATRIX IS ONLY INTENDED TO SHOW THE MAJOR SYSTEM FUNCTIONS, SYSTEM SHALL ALSO PERFORM INPUTS/OUTPUTS REQUIRED BY NFPA 72, NFPA 2001 AND
MANUFACTURE REQUIREMENTS. BN1 CONTROL ROOM EL 65. FSCP BATTERIES SHALL BE SIZED FOR 120 HOURS STANDBY WITH 15 MINUTES OF ALARM.
17 ANY TROUBLE ALARM X X X X X 17
18 POST DISCHARGE EXHAUST SWITCH X X X X X X X 18
A B C D E F G H I J K L M N O P Q R S T U V W X Y
13 LOW BATTERY X X X X X 13
14 ANY OPEN CIRCUIT X X X X X 14
15 ANY GROUND FAULT X X X X X 15
16 ANY NOTIFICATION APPLIANCE CIRCUIT SHORT X X X X X 16
1 CLEAN AGENT MANUAL RELEASE STATION X X X X X X X X X X X 1
2 DEPRESS ABORT STATION(NON-ALARM CONDITION) X X X X X X 2
3 DEPRESS ABORT STATION (PRE-ALARM CONDITION) X X X X X X X 3
4 RELEASE ABORT STATION (PRE-ALARM CONDITION) X X X X X X X X X 4
5 SMOKE DETECTOR X X X X X X 5
6 HEAT DETECTOR - FIRST X X X X X X 6
7 HEAT DETECTOR - TWO OR MORE X X X X X X X X X X X 7
8 30 SECOND DISCHARGE TIMER COMPLETE X X 8
9 KEYED MAINTENANCE SWITCH X X X X X X 9
10 DISCHARGE PRESSURE SWITCH X X X X X X X X X X 10
11 ACTUATOR REMOVED FROM STORAGE CONTAINER X X X X X X 11
12 AC POWER FAILURE X X X X X 12
NOTIFICATION INTERFACE ANNUNCIATION
D
IS
P L
A Y A
L A
R M C
O N
D
IT
IO
N A
T F
A C
P
D
IS
P L
A Y S
U P
E R
V
IS
O R
Y C
O N
D
IT
IO
N A
T F
A C
P
D
IS
P L
A Y T
R O
U B
L E C
O N
D
IT
IO
N A
T F
A C
P
M A
N U
A L E
X H
A U
S T S
Y S
T E
M A
C T
IV
A T
E D
A C
T
IV
A T
E C
L E
A N A
G E
N T P
R E -D
IS
C H
A R
G E H
O R
N /S
T R
O B
E B
P M H
O R
N /B
L U
E S
T R
O B
E
A C
T
IV
A T
E C
L E
A N A
G E
N T D
IS
C H
A R
G E H
O R
N /S
T R
O B
E
C O
N T
IN
U O
U S H
O R
N /C
L E
A R S
T R
O B
E
A C
T
IV
A T
E C
L E
A N A
G E
N T T
R O
U B
L E H
O R
N /S
T R
O B
E S
L O
W W
H O
O P /A
M B
E R S
T R
O B
E
S T
A R
T D
IS
C H
A R
G E D
E L
A Y T
IM
E R S
E C
O N
D S
A C
T
IV
A T
E A
G E
N T R
E L E
A S
E A
C T
U A
T
E V
E N
T A
C T
IV
A T
IO
N O
F A
G E
N T R
E L E
A S
E A
C T
U A
T O
R
A C
T
IV
A T
E D
A M
P E
R A
N D D
O O
R C
L O
S U
R E I
N A
S S
O C
IA
T E
D S
P A
C E
A C
T
IV
A T
E A
S S
O
IC
A T
E D P
O W
E R
H O
U S
E F
IR
E A
L A
R M S
Y S
T E
M
A C
T
IV
A T
E M
A N
U A
L E
X A
U S
T S
Y S
T E
M F
A N
S
T R
A N
S M
IT
A
L A
R M S
IG
N A
L T
O B
N A
N N
U N
C
IA
T O
R
B N
I
N P
U T S O
N L
Y
T R
A N
S M
IT
T
R O
U B
L E S
IG
N A
L T
O B
N A
N N
U N
C
IA
T O
R
B N
I
N P
U T S O
N L
Y
T R
A N
S M
IT
A
L A
R M S
IG
N A
L T
O B
N A
N N
U N
C
IA
T O
R
B N
I
N P
U T S O
N L
Y
T R
A N
S M
IT
T
R O
U B
L E S
IG
N A
L T
O B
N A
N N
U N
C
IA
T O
R
B N
I
N P
U T S O
N L
Y
T R
A N
S M
IT
A
L A
R M S
IG
N A
L T
O B
N M
A
IN
F
A C
P
B N
I
N P
U T S O
N L
Y
T R
A N
S M
IT
T
R O
U B
L E S
IG
N A
L T
O B
N M
A
IN
F
A C
P
B N
I
N P
U T S O
N L
Y
T R
A N
S M
IT
S
U P
E R
V
IS
O R
Y S
IG
N A
L T
O B
N M
A
IN
F
A C
P
B N
I
N P
U T S O
N L
Y
T R
A N
S M
IT
A
L A
R M S
IG
N A
L T
O B
N M
A
IN
F
A C
P
B N
I
N P
U T S O
N L
Y
T R
A N
S M
IT
T
R O
U B
L E S
IG
N A
L T
O B
N M
A
IN
F
A C
P
B N
I
N P
U T S O
N L
Y
T R
A N
S M
IT
S
U P
E R
V
IS
O R
Y S
IG
N A
L T
O B
N M
A
IN
F
A C
P
B N
I
N P
U T S O
N L
Y
S H
U T
D O
W N A
S S
O C
IA
T E
D E
X H
A S
T F
A N (S
S H
U T
D O
W N A
S S
O C
IA
T E
D O
IL
P
U M
P (S
A N
D P
U R
IF
IE
R (S
INPUTS A B C D E F G H I J K L M N O P Q R S T U V W X Y
o le F ir e P r o t e c t io n W e s t s t S tr e e t
O la th e
K S
.8
.8 o ff
.8
.8 f a x w w w .p o o le fi re .c o m
PLAN NORTH
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
PLAN NORTH
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
1HD1
C A
1MSS4
CA
C
M
S S
C A
1MSS3
C A
1MSS2
C
A1MRS2
C
A1AS2
D
R 1DR1
1HD5
1HD9
C
A1MRS3
C
A1AS3
C
A 1AS1
C
A 1MRS1
A
CA
C
C
T S
C A
B1WPS3
C A
A1WTS3
C A
B 1WPS1
C A
A 1WTS1
C A
B1WPS2
C A
A1WTS2
CM
C
M
LP
L P
PS
P
S
SO
1SO
K S
K
S F S
C P
1HD7
1HD3
20'
1HD10
1HD6
1HD8
1HD4
1HD2
B
CA
C
C
P S s
1SD
FSCP
A
2 3 4 5 6
US Army Corps of Engineers ®
SHEET
IDENTIFICATION
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C K
D B
Y
A N
S I F
D A
T E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
D A
T E
D E
S
IG
N F
IL
E
DATE AND TIME PLOTTED::
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
P L
O T S
C A
L E
P L
O T D
A T
E
F
IL
E N
A M
E
F
IL
E N
U M
B E
R
BY USERNAME: SHEET NAME:
B
C
D
E
DRAWING PLOT SIZE: 40x28 ANSI F SBRINKMEYER
PORTLAND DISTRICT
1/17/2019 8:39:53 AM
FA1101
F
IR
E A
L A
R M P
L A
N B
N
B O
N N
E V
IL
L E L
O C
K A
N D D
A M
P O
R T
L A
N D D
IS
T R
IC
T
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
J P
A H
L O
W
J P
A H
L O
W A P
O O
L E
W
N
B
O
IL
S
T O
R A
G E R
O O
M
F
IR
E P
R O
T E
C T
IO
N
/1
/2
B D
P .1
F
A .D
G N
FIRE ALARM PLAN - BN1
F
IR
S T P
O W
E R
H O
U S
E
B D
P .1
F
A .D
G N
SCALE: 1/4" = 1'-0"
A3
BN1 OIL STORAGE ROOM CLEAN AGENT DEVICE LAYOUT - EL +10.00
SCALE: 1/4" = 1'-0"
D4
BN1 CYLINDERS AND ROUTING VALVES - ELECTRICAL - EL +37.00
OIL STORAGE ROOM DIMENSIONS:
LENGTH: 80'
WIDTH: 20'
HEIGHT: 19'
A D
V E
R T
IS
E
/1
/2
LOCATED NEAR
BASE OF STAIRS
ELEVATOR
HATCH
ELEVATOR
HATCH
UTILITY
HATCH
PROVIDE NEW CONTROL
MODULE FOR EXISTING
EXHAUST FAN TO REMAIN.
EXHAUST FAN MUST BE
CAPABLE OF BEING TURNED
ON MANUALLY AFTER
SYSTEM DISCHARGE
CLEAN AGENT
CYLINDER
EL +23.5
NEW FSCP TO
BE INSTALLED
C L P
IE
R
C L U
N
IT
INITIAL DISCHARGE CYLINDERS
(48 TOTAL, 24 ON EACH SIDE)
EXTENDED DISCHARGE CYLINDERS
(30 TOTAL, 15 ON EACH SIDE)
ROUTING VALVES EXISTING FSCP TO REMAIN.
o le F ir e P r o t e c t io n W e s t s t S tr e e t
O la th e
K S
.8
.8 o ff
.8
.8 f a x w w w .p o o le fi re .c o m
A
2 3 4 5 6
US Army Corps of Engineers ®
SHEET
IDENTIFICATION
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C K
D B
Y
A N
S I F
D A
T E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
D A
T E
D E
S
IG
N F
IL
E
DATE AND TIME PLOTTED::
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
P L
O T S
C A
L E
P L
O T D
A T
E
F
IL
E N
A M
E
F
IL
E N
U M
B E
R
BY USERNAME: SHEET NAME:
B
C
D
E
DRAWING PLOT SIZE: 40x28 ANSI F SBRINKMEYER
PORTLAND DISTRICT
1/17/2019 8:39:55 AM
FA1501
F
IR
E A
L A
R M D
E T
A
IL
S B
N
B O
N N
E V
IL
L E L
O C
K A
N D D
A M
P O
R T
L A
N D D
IS
T R
IC
T
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
J P
A H
L O
W
J P
A H
L O
W A P
O O
L E
W
N
B
O
IL
S
T O
R A
G E R
O O
M
F
IR
E P
R O
T E
C T
IO
N
/1
/2
B D
P .1
F
A .D
G N
FIRE ALARM DETAILS - BN1
F
IR
S T P
O W
E R
H O
U S
E
B D
P .1
F
A .D
G N
SCALE: NTS
A2
TYPICAL FIRE ALARM DEVICE MOUNTING DETAILS - BN1
A D
V E
R T
IS
E
/1
/2
HORN BEACON OR STROBE
T O O
P E
R A
B L E P
A R
T
5' MAX.B
O
T T
O M O
F L
E N
S
M
IN
T O
P O
F L
E N
S
M A
X
T O
P O
F D
E V
IC
E
M
IN
T O
P
V
IC
E
M
IN
4" MIN.
MANUAL RELEASE
STATION
ABORT STATION
" M
A X . O
R
" M
IN
SMOKE OR HEAT DETECTORS
o le F ir e P r o t e c t io n W e s t s t S tr e e t
O la th e
K S
.8
.8 o ff
.8
.8 f a x w w w .p o o le fi re .c o m
PLAN NORTH
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
PLAN NORTH
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
OIL STORAGE
ROOM
BN1
20'
OIL STORAGE
ROOM
BN1
20'
A
2 3 4 5 6
US Army Corps of Engineers ®
SHEET
IDENTIFICATION
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C K
D B
Y
A N
S I F
D A
T E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
D A
T E
D E
S
IG
N F
IL
E
DATE AND TIME PLOTTED::
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
P L
O T S
C A
L E
P L
O T D
A T
E
F
IL
E N
A M
E
F
IL
E N
U M
B E
R
BY USERNAME: SHEET NAME:
B
C
D
E
DRAWING PLOT SIZE: 40x28 ANSI F SBRINKMEYER
PORTLAND DISTRICT
1/17/2019 8:40:31 AM
FX1101
O
IL
S
T O
R A
G E R
O O
M C
L E
A N A
G E
N T P
IP
IN
G
A R
R A
N G
E M
E N
T B
N
B O
N N
E V
IL
L E L
O C
K A
N D D
A M
P O
R T
L A
N D D
IS
T R
IC
T
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
J P
A H
L O
W
J P
A H
L O
W A P
O O
L E
W
N
B
O
IL
S
T O
R A
G E R
O O
M
F
IR
E P
R O
T E
C T
IO
N
/1
/2
B D
P .1
F
X .D
G N
OIL STORAGE ROOM CLEAN AGENT PIPING ARRANGEMENT - BN1
F
IR
S T P
O W
E R
H O
U S
E
B D
P .1
F
X .D
G N
SCALE: 1/4" = 1'-0"
A1
BN1 OIL STORAGE ROOM MECHANICAL PLAN LOWER NOZZLES EL. +19.00
SCALE: 1/4" = 1'-0"
A4
BN1 OIL STORAGE ROOM MECHANICAL PLAN UPPER NOZZLES EL. +28.00
A D
V E
R T
IS
E
/1
/2
C2
FX1301
C2
FX1301
ELEVATOR
HATCH
ELEVATOR
HATCH
UTILITY
HATCH
o le F ir e P r o t e c t io n W e s t s t S tr e e t
O la th e
K S
.8
.8 o ff
.8
.8 f a x w w w .p o o le fi re .c o m
0 2' 4' 8'
SCALE: 1/4" = 1'-0"
EL 10.0
10' - 0"
EL 28.94
28' - 11 9/32"
EL 29.41
29' - 4 29/32"
OIL STORAGE
ROOM
BN1
A
2 3 4 5 6
US Army Corps of Engineers ®
SHEET
IDENTIFICATION
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C K
D B
Y
A N
S I F
D A
T E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
D A
T E
D E
S
IG
N F
IL
E
DATE AND TIME PLOTTED::
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
P L
O T S
C A
L E
P L
O T D
A T
E
F
IL
E N
A M
E
F
IL
E N
U M
B E
R
BY USERNAME: SHEET NAME:
B
C
D
E
DRAWING PLOT SIZE: 40x28 ANSI F SBRINKMEYER
PORTLAND DISTRICT
1/17/2019 8:40:32 AM
FX1301
C L E
A N A
G E
N T S
E C
T
IO
N S B
N
B O
N N
E V
IL
L E L
O C
K A
N D D
A M
P O
R T
L A
N D D
IS
T R
IC
T
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
J P
A H
L O
W
J P
A H
L O
W A P
O O
L E
W
N
B
O
IL
S
T O
R A
G E R
O O
M
F
IR
E P
R O
T E
C T
IO
N
/1
/2
B D
P .1
F
X .D
G N
CLEAN AGENT SECTIONS - BN1
F
IR
S T P
O W
E R
H O
U S
E
B D
P .1
F
X .D
G N
SCALE: 1/4" = 1'-0"
C2
CLEAN AGENT SECTIONS - BN1 A
D
V E
R T
IS
E
/1
/2 o le F ir e P r o t e c t io n W e s t s t S tr e e t
O la th e
K S
.8
.8 o ff
.8
.8 f a x w w w .p o o le fi re .c o m
PUSH
PULL
PUSH/HOLD
SUPPRESSION SYSTEM ABORT
A
2 3 4 5 6
US Army Corps of Engineers ®
SHEET
IDENTIFICATION
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C K
D B
Y
A N
S I F
D A
T E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
D A
T E
D E
S
IG
N F
IL
E
DATE AND TIME PLOTTED::
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
P L
O T S
C A
L E
P L
O T D
A T
E
F
IL
E N
A M
E
F
IL
E N
U M
B E
R
BY USERNAME: SHEET NAME:
B
C
D
E
DRAWING PLOT SIZE: 40x28 ANSI F SBRINKMEYER
PORTLAND DISTRICT
1/17/2019 8:40:33 AM
FX1501
C L E
A N A
G E
N T D
E T
A
IL
S B
N
B O
N N
E V
IL
L E L
O C
K A
N D D
A M
P O
R T
L A
N D D
IS
T R
IC
T
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
J P
A H
L O
W
J P
A H
L O
W A P
O O
L E
W
N
B
O
IL
S
T O
R A
G E R
O O
M
F
IR
E P
R O
T E
C T
IO
N
/1
/2
B D
P .1
F
X .D
G N
CLEAN AGENT DETAILS - BN1
F
IR
S T P
O W
E R
H O
U S
E
B D
P .1
F
X .D
G N
SCALE: NTS
A1
CLEAN AGENT START/STOP STATION DETAIL - BN1
SCALE: NTS
A4
CLEAN AGENT SIGNAGE - BN1
A D
V E
R T
IS
E
/1
/2
FIRE
SUPPRESSION
MANUAL
RELEASE
FIRE
SUPPRESSION
ABORT
PUSH BUTTON
AND HOLD
FIRE SUPPRESSION SYSTEM
MAINTENANCE SWITCH
TO OPERATE TURN KEY TROUBLE WILL
OCCUR AT PANEL NOVEC 1230 SYSTEM
RELEASE CIRCUIT WILL BE DISABLED
FIRE SUPPRESSION SYSTEM
DISCHARGE LIGHT
WHEN LIGHT IS FLASHING DO NOT
ENTER. NOVEC 1230 SYSTEM HAS
DISCHARGED
o le F ir e P r o t e c t io n W e s t s t S tr e e t
O la th e
K S
.8
.8 o ff
.8
.8 f a x w w w .p o o le fi re .c o m
A
2 3 4 5 6
US Army Corps of Engineers ®
SHEET
IDENTIFICATION
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C K
D B
Y
A N
S I F
D A
T E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
D A
T E
D E
S
IG
N F
IL
E
DATE AND TIME PLOTTED::
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
P L
O T S
C A
L E
P L
O T D
A T
E
F
IL
E N
A M
E
F
IL
E N
U M
B E
R
BY USERNAME: SHEET NAME:
B
C
D
E
DRAWING PLOT SIZE: 40x28 ANSI F SBRINKMEYER
PORTLAND DISTRICT
1/17/2019 8:40:25 AM
FX1001
C L E
A N A
G E
N T G
E N
E R
A L N
O T
E S B
N
B O
N N
E V
IL
L E L
O C
K A
N D D
A M
P O
R T
L A
N D D
IS
T R
IC
T
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
J P
A H
L O
W
J P
A H
L O
W A P
O O
L E
W
N
B
O
IL
S
T O
R A
G E R
O O
M
F
IR
E P
R O
T E
C T
IO
N
/1
/2
B D
P .1
F
X .D
G N
CLEAN AGENT GENERAL NOTES - BN1
F
IR
S T P
O W
E R
H O
U S
E
B D
P .1
F
X .D
G N
A D
V E
R T
IS
E
/1
/2
1.
2.
3.
4.
5.
UNCLOSABLE OPENINGS MUST BE KEPT TO A MINIMUM.
ANY OPENINGS IN THE ENCLOSURE WALLS, CEILING, AND FLOOR
MUST BE PERMANENTLY SEALED OR PROVIDED WITH AUTOMATIC
CLOSURES.
IF CONFINEMENT OF AGENT IS NOT PRACTICABLE, PROTECTION
MUST BE EXTENDED TO INCLUDE THE ADJACENT AREAS.
FORCED-AIR VENTILATING SYSTEMS, INCLUDING SELF-CONTAINED
AIR-RECIRCULATION SYSTEMS MUST BE SHUT DOWN OR CLOSED
AUTOMATICALLY.
THE ENCLOSURE MUST HAVE THE STRUCTURAL STRENGTH AND
INTEGRITY NECESSARY TO CONTAIN THE AGENT DISCHARGE. IF
THE DEVELOPED PRESSURES PRESENT A THREAT TO THE
STRUCTURAL STRENGTH OF THE ENCLOSURE, VENTING MUST BE
PROVIDED TO PREVENT EXCESSIVE PRESSURES AND AGENT
QUANTITIES INCREASED TO ACCOUNT FOR VENTING.
ENCLOSURE NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
FITTINGS MUST CONFORM TO THE REQUIREMENTS OF NFPA 2001,
2018 EDITION.
FITTINGS MUST BE PER MANUFACTURER'S RECOMMENDATIONS.
ALL GROOVED COUPLINGS AND FITTINGS MUST BE UL LISTED
AND/OR FM APPROVED AND HAVE A MINIMUM RATED WORKING
PRESSURE EQUAL TO OR GREATER THAN THE MINIMUM PIPING
DESIGN PRESSURE.
CONCENTRIC BELL REDUCERS ARE THE ONLY MEANS FOR
REDUCING PIPE SIZE.
PIPE SIZE REDUCTIONS MAY BE MADE AFTER A TEE OR AFTER A
UNION.
WHERE REDUCERS ARE USED AT TEES, THE REDUCERS MUST BE
DOWNSTREAM OF EACH TEE.
PIPING MUST BE SECURELY BRACED TO ACCOUNT FOR
DISCHARGE REACTION FORCES AND THERMAL
EXPANSION/CONTRACTION. CARE MUST BE TAKEN TO ENSURE THE
PIPING IS NOT SUBJECTED TO VIBRATION, MECHANICAL OR
CHEMICAL DAMAGE.
ALL PIPE HANGERS MUST BE UL LISTED, CONFORM TO GENERAL
INDUSTRY STANDARDS FOR PIPE HANGERS, AND CONFORM TO
ANSI B-31.1. REFER TO ANSI B-31.1 FOR ADDITIONAL BRACING
REQUIREMENTS.
DISCHARGE PIPE AND FITTING NOTES:
1.
2.
3.
4.
THE CYLINDER SHOULD BE LOCATED IN A PLACE WHICH IS
READILY ACCESSIBLE FOR MANUAL ACTUATION AND INSPECTION,
SERVICE AND MAINTENANCE.
CYLINDERS MUST BE LOCATED IN AN ENVIRONMENT PROTECTED
FROM THE WEATHER, AND WHERE THE AMBIENT TEMPERATURE
DOES NOT EXCEED 80°F OR FALL BELOW 60°F.
CYLINDERS MUST BE LOCATED AND MOUNTED WHERE THEY WILL
NOT BE ACCIDENTALLY DAMAGED OR MOVED. INSTALL SUITABLE
PROTECTION TO PREVENT THE CYLINDERS FROM DAMAGE OR
MOVEMENT.
POSITION THE CYLINDERS IN THE DESIGNATED LOCATION AND
SECURE THEM IN PLACE WITH CYLINDER STRAPS AND ATTACHING
HARDWARE AS RECOMMENDED BY THE MANUFACTURER.
AGENT STORAGE CYLINDER NOTES:
1.
2.
3.
4.
NOZZLE PLACEMENT MUST BE SUCH THAT THE DESIGN
CONCENTRATION WILL BE ESTABLISHED IN ALL PARTS OF THE
HAZARD ENCLOSURE.
NOZZLES MUST BE MOUNTED PERPENDICULAR TO THE CEILING
AND ORIENTED WITH THE ORIFICES RADIATING SYMMETRICALLY
OUTWARD FROM THE PIPE NETWORK.
NOZZLES MUST BE INSTALLED SO THAT THE ORIFICES ARE
LOCATED AT DISTANCES BELOW THE CEILING AND AWAY FROM
WALLS ACCORDING TO MANUFACTURERS RECOMMENDATIONS.
NOZZLES MUST BE LOCATED ACCORDING TO MANUFACTURERS
RECOMMENDED CLEARANCE FROM WALLS AND/OR SIGNIFICANT
OBSTRUCTIONS TO ALLOW FLUID DISCHARGE TO FULLY ATOMIZE.
AGENT DISCHARGE NOZZLE NOTES:
NEW FIRE SUPPRESSION EQUIPMENT
LEGEND
SYMBOL DESCRIPTION
180° DISCHARGE NOZZLE
AGENT DISCHARGE PIPING
DEMO FIRE ALARM DEVICE LEGEND
EXISTING CONCRETE WALL
CALCULATIONS AND SYSTEM DESIGN ARE BASED ON FK-5-1-12.
THE SYSTEM IS DESIGNED TO EXTINGUISH A SINGLE FIRE.
THE SYSTEM IS DESIGNED FOR TOTAL FLOODING.
ENCLOSURE: BN1 OIL STORAGE ROOM
HAZARD CLASSIFICATION: CLASS B, LUBE OIL
MINIMUM DESIGN CONCENTRATION: 5.85% (PER MANUFACTURE DATA SHEETS)
RAISED FLOOR: NONE
SUNKEN FLOOR: NONE
MINIMUM ANTICIPATED TEMPERATURE: 60°F
ELEVATION: 170 FT.
EQUIVALENT ALTITUDE: 0 FT.
ATMOSPHERIC CORRECTION FACTOR: 1.00
LENGTH(L): 80 FT.
WIDTH(W): 20.33 FT.
HEIGHT(H): 19.41 FT.
(VE) ENCLOSURE VOLUME:
VE=((L)(W)(H))
VE=(80)(20.33)(19.41)
VE=31,569 CU. FT.
(VD) NON-PERMEABLE VOLUME (OIL STORAGE TANKS)
VD=((8,800 GAL) + (2 * 5,000 GAL)) * 0.133681 CU.FT/GAL
VD=18,800 GAL * 0.133681 CU.FT./GAL
VD=2,513 CU. FT
(VT) TOTAL VOLUME
VT=VE-VD
VT=31,569 CU. FT. - 2,513 CU. FT.
VT=29,056 CU. FT
(S) SPECIFIC VOLUME AT 1 ATM AND 60F=1.13206
(TABLE A.5.5.1(a), NFPA 2001 (2018 EDITION))
(C) AGENT CONCENTRATION REQUIRED (CLASS B FIRE)=5.85%
(W) TOTAL DESIGN QUANTITY CALCULATED AS FOLLOWS:
W=(VT/S)*((C)/(100-C))
=(29,056/1.13206)*((5.85)/(100-5.85)
=1,594.8 LBS
=1,595 LBS
TOTAL MINIMUM AGENT DESIGN QUANTITY: 1,595 LBS.
THIS CALCULATION ESTIMATES THE QUANTITY OF AGENT REQUIRED TO
EXTINGUISH A FIRE AND REQUIRED SIZE OF AGENT STORAGE TANK. THE
COMPLEXITY OF TWO-PHASE FLOW DOES NOT ALLOW FOR MANUAL FLOW
CALCULATION. FOR THIS REASON, THE FLOW CALCULATIONS MUST BE
EXECUTED WITH LISTED SOFTWARE PROVIDED BY THE MANUFACTURER TO
DETERMINE PIPE SIZE, NOZZLE FLOW RATE, NOZZLE PRESSURE, NOZZLE ORIFICE
AREA, AND TO DEMONSTRATE THE SYSTEM ACHIEVES 95 PERCENT OF THE
MINIMUM DESIGN CONCENTRATION FOR FLAME EXTINGUISHMENT IN 10 SECONDS
OR LESS, AS PRESCRIBED BY NFPA 2001 (2018 EDITION).
A MINIMUM CONCENTRATION OF 85 PERCENT OF THE ADJUSTED MINIMUM DESIGN
CONCENTRATION MUST BE HELD AT THE HIGHEST HEIGHT OF PROTECTED
CONTENT WITHIN THE HAZARD FOR A PERIOD OF TEN MINUTES OR FOR A TIME
PERIOD SUFFICIENT TO ALLOW FOR RESPONSE BY TRAINED PERSONNEL.
CLEAN AGENT CALCULATION BN1 - OIL STORAGE ROOM
o le F ir e P r o t e c t io n W e s t s t S tr e e t
O la th e
K S
.8
.8 o ff
.8
.8 f a x w w w .p o o le fi re .c o m
A
2 3 4 5 6
US Army Corps of Engineers ®
SHEET
IDENTIFICATION
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
C K
D B
Y
A N
S I F
D A
T E
C O
N T
R A
C T N
O
S O
L
IC
IT
A T
IO
N N
O
D A
T E
D E
S
IG
N F
IL
E
DATE AND TIME PLOTTED::
M A
R K
D E
S C
R
IP
T
IO
N A
P P
R
P L
O T S
C A
L E
P L
O T D
A T
E
F
IL
E N
A M
E
F
IL
E N
U M
B E
R
BY USERNAME: SHEET NAME:
B
C
D
E
DRAWING PLOT SIZE: 40x28 ANSI F SBRINKMEYER
PORTLAND DISTRICT
1/17/2019 8:40:35 AM
FX1901
P
IP
IN
G I S
O M
E T
R
IC
B
N
B O
N N
E V
IL
L E L
O C
K A
N D D
A M
P O
R T
L A
N D D
IS
T R
IC
T
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
P O
R T
L A
N D
O R
E G
O N
J P
A H
L O
W
J P
A H
L O
W A P
O O
L E
W
N
B
O
IL
S
T O
R A
G E R
O O
M
F
IR
E P
R O
T E
C T
IO
N
/1
/2
B D
P .1
F
X .D
G N
PIPING ISOMETRIC - BN1
F
IR
S T P
O W
E R
H O
U S
E
B D
P .1
F
X .D
G N
SCALE: NTS
A1
BN1 OIL STORAGE ROOM CLEAN AGENT PIPING ISOMETRIC
A D
V E
R T
IS
E
/1
/2
MAXIMUM DISTANCE BETWEEN HANGERS
NOMINAL
PIPE SIZE (in.)
STEEL PIPE 9' 9' 9' 12' 13' 14' 15' 17'
3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 4"3"
FASTENER CHART
PIPE SIZE
UP TO 2"
UP TO 2"
2-1/2" TO 4"
EYE RODS / SIDE BEAM HANGERS ROD SIZE
(2) #16 x 2" DRIVE SCREWS
3/8" x 2-1/2" LAG SCREWS
1/2" x 3" LAG SCREWS
3/8"
3/8"
3/8"
/2
NOTES:
8.
7.
6.
5.
4.
3.
2.
1.
WALLS OF THE OIL STORAGE ROOM.
INSTALL PIPE CAPS ON PIPING TO BE REMOVED OUTSIDE OF THE
INSTALL NEW GATE VALVE AND BLIND FLANGE ON 4" DRAIN LINE .
FLUSH TO THE EXISTING FLOOR.
NO. 1, 2 AND 3 AND PUMPS NO. 1, 2 AND 3. CUT AND GRIND BASES
REMOVE EXISTING CONCRETE AND GROUT BASES FOR TANKS
PIPE DEMOLITION.
WELD PIPE CAPS TO ALL OPEN PIPE ENDS WHICH RESULT FROM
TANKS 4, 5 AND 6.
REMOVE PIPING WHICH INTERCONNECTS TANKS NO. 1, 2 AND 3 TO
REMOVE PUMPS NO. 1, 2 AND 3 AND ASSOCIATED PIPING.
TRANSFORMER.
SUPPLY AND RETURN PIPING BETWEEN OIL STORAGE ROOM AND
REMOVE ALL NON-EMBEDDED TRANSFORMER AND BREAKER OIL
WHERE PIPE IS EMBEDDED.
FOR FOR TRANSFORMER OIL AND BREAKER OIL UP TO THE POINT
NO. 1, 2 AND 3 AND ALL ASSOCIATED PIPE IN OIL STORAGE ROOM
REMOVE ITEMS SHOWNIN BOLD INCLUDING EXISTING OIL TANKS
DRAWING PLOT SIZE: ANSI D
D
C
A
B
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R
/2
/2
BORDER VERSION UPDATE [09-2012]
MD001SHEET NAME:g2hdcgp9 MSTforACAD-V8i-IntroBY USERNAME:DATE AND TIME PLOTTED: 10/21/2019 11:31:59 AM of Engineers
US Army Corps
A D
V E
R T
IS
E
S
U C
T
IO
N F
R O
M T
A N
K
S
U C
T
IO
N F
R O
M T
A N
K
A
S
U C
T
IO
N F
R O
M T
A N
K
T R
A N
S
IL
O
IL
R
E T
U R
N
D O
W N S
U C
T
IO
N F
R O
M T
A N
K
T O F
IL
T E
R S
U C
T
T R
A N
S
IL
O
IL
S
U C
T
IO
N F
R O
M T
A N
K
B
T O S
U C
T
IO
N -P
U M
P S
,2 ,3
D
IS
C H
A R
G E F
R O
M T
A N
K
A
D O
W N S
U C
T
IO
N F
R O
M T
A N
K
D
IS
C H
A R
G E F
R O
M T
A N
K
D O
W N
D
IS
C H
A R
G E T
O T
A N
K
D
O W
N
T O T
A N
K
D O
W N F
R O
M F
IL
T E
R
T R
A N
S
IL
O
IL
S
U P
P L
Y
TANK NO 3
4" OVERFLOW
ELEV 24'-8"
2" VENTS
TO ROOF
ELEV 27'-8"
UP TO ELEV 55.0
SEE P-5-364
PUMP DISCHARGE
3" TRANSIL OIL RETURN
BREAKER OIL
TRANSFORMER AND
4" SUCTION HEADER-
FILTER-LUB. OIL
3" DISCHARGE FROM
FILTER SUCTION
3" LUB. OIL TO
4" FROM TANK 6A
" DRAIN HEADER2
4" DISCHARGE HEADER
TRANSFORMER & BREAKER OIL
WALKWAY
GAUGE. SEE P-11-348B
2" TEE FOR LIQUID
ELEV 24.0 4" 4"
6"
O.S.&Y
GATE VALVES
4"
U P T
O E
L E
V .0
TRANSFORMER & BREAKER OIL
" HOSE2
CONN
PUMPS #1,2,3
3" TO DUCTION OF
4" FROM TANK 6B
1"
4"4" 4" 4" 4"
3"
3"4"4"
4" ELEV +10.0
4"
"2
3"
4"
ONE-TO FIT ALL TANKS
" REMOVABLE PIPE CONNECTION2
" UNION2
VALVE
" GATE2
4"
4"
4" 4"
4"
2"
"2
CLEAN LUBE OIL
GAUGE
TEE FOR
4"
4"
2"
2"
2"
EL & 24'-8"
2" VENT
EL & 24'-8"
2" VENT
4"
4"
4"
4"
4"
2"
2"
4"
3"
3"
4"
OPEN END AT ELEV.+11'-0"
4" VENT OVERFLOW-DOWN
4" STRAP AT FLOOR
IN PLACE
FLOOR DRAIN
4" SUCTION FROM TANK 6A-EL. +10'-4"
"2
1" DRAIN HEADER EL. +10'-8 2
3" TO FILTER SUCTION- EL. +10'-4"
3" TO FILTER DISCH.- ELEV. +10'-4"
3" TO PUMP SUCTION- FROM TANK 5
FROM FILTER
3" LUBE OIL-DISCHARGE
3" TO PUMP SECTION
3" TO FILTER SECTION
6"
6"
6"
3" LUB. OIL SUPPLY
6" LUB. OIL DRAIN
3" LUB. OIL RETURN
6" OIL DRAIN FROM TRANSFORMERS & BREAKERS
3" OIL SUPPLY TO TRANSFORMERS & BREAKERS
3" OIL RETURN FROM TRANSFORMERS & BREAKERS
1" WATER 1" COMP. AIR
3" DISCHARGE FROM FILTER- TRANSIL OIL
3" TO FILTER SUCTION- TRANSIL OIL
3" DISCHARGE FROM FILTER- LUBE OIL
3" TO FILTER SUCTION- LUBE OIL
CO2 PIPES
3" BYPASS DOWN TO FILTER SUCTION
GENERAL SERVICE
7'-6"
5'-4"" SUCTION2
" BYPASS2
TO PUMP SECTION
4"
4"
3" 4"
6"
3"
4"
2"
4"
4"
2"
4"
4"
2" TEE FOR GAUGE
BREAKER OIL-RECIEVING TRANSFORMER OIL NEW OR DIRTY CLEAN TRANSFORMER OIL
" DISCHARGE2
EL +11'-0"
3" TO FILTER SUCTION
6"x11" BLIND FLANGE
DRAIN HEADER
" TO FILTER SUCTION- FROM 2
4"
6"
4"
3" 3"
4" 4"
6"
6"
8"
4"
4"
3"
2"
6"
6" 4" OVERFLOW- EL. 21'-8"
EL 24'-8"
2" VENT
"2
13" FROM FILTER DISCH. EL. 10'-8
"2
1 EL. 10'-8
3" TO SUCTION OF PUMPS 2&3
TRANSFORMERS & BREAKERS
3" OIL SUPPLY TO
4" SUCTION FROM TANK 6A
OIL STORAGE ROOM DEMOLITION
PLAN EL - 10.00
SECTION B-B
SCALE 3/8" = 1'-0"
SCALE 3/8" = 1'-0"
SEE NOTE 1 AND 2 SEE NOTE 6
SEE NOTE 3
NUMBER 6B
TANK
NUMBER 5
TANK
NUMBER 4
TANK
LUBE OIL-RECEIVING
NUMBER 3
TANK
NUMBER 2
TANK
NUMBER 1
TANK
SEE NOTE 7
SEE NOTE 8
TANK NO. 6A
(8500 GAL)
(5000 GAL) (5000 GAL)
(8500 GAL) (8500 GAL) (12,500 GAL)
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D D
IS
T R
S
N N
E V
IL
L E L
O C
K A
N D D
IR
E P
R O
T E
C T
IO
N
R
V A
U G
H N
J
IM
B
R U
N O
T
P O
R T
L A
N D
O R
E G
O N
F
IR
S T P
O W
E R
H O
U S
E
O
IL
S
T O
R A
G E R
O O
M
D E
M O
L
IT
IO
N
S H
E E
T
B D
P .1
M D
.d g n
MD002
E
MD002
E
MD002
C
MD002
C
B
MD001
B
MD001
R S
T R
IN
G F
E L L
O W
W
N
B
MD1001
S L
O R
E N
Z
/2
'-0
'-0
'-0 " 12
'-0
7'- 6"
7'- 6"
PUMP NO. 1
SEE P-8-313
OF WALKWAYS
FOR DETAILS
'-0
7'- 6"
NO. 4
PUMP
(TYP OF 8)
LINE LUBE OIL
6" FILL & DRAIN
SCALE = 1/2" = 1'-0"
SCALE = 1/4" = 1'-0"
EL. +19.5
WALKWAY
4"
LUBE OIL
HEADER
4" SUCTION
DISCH
FILTER
FROM
3" LUB. OIL
3"
3"
2" 2"
ELLS
2"x1 1/2"
1 1/2" GV
1 1/2" GV
1 1/2"
ELLS
2"x1 1/2"
LUBE OIL
HEADER
4" SUCTION
OIL RETURN
3" TRANSIL
OIL RETURN
3" TRANSIL
VALVE
1" GLOBE
SEE NOTE 4
SEE NOTE 1
SECTION E-E
SECTION C-C
ELEVATION +10.0
ELEVATION 21.75
ELEVATION 23.75
ELEVATION 27.66
ELEVATION 28.68
ELEVATION 28.94
SEE NOTE 1
OIL RECEIVING
BREAKER
TANK NUMBER 3
LUB OIL CLEAN
TANK NUMBER 4
IN
S D
IA
HEADER
DISCH
3" LUB. OIL
SUPPLY
3" LUBE OIL
RETURN
3" LUBE OIL
IN
S
DI
A
IN
S
DI
A
IN
S
DI
A IN
S
DI
A
IN
S
DI
A
IN
S
DI
A
ELEVATION 28.68
ELEVATION +19.50
IN
S
DI
A
ELEVATION +21.75
ELEVATION 28.94
ELEVATION 23.75
ELEVATION +10.00
OIL CLEAN
TRANSFORMER
TANK NUNBER 1
OIL NEW OR DIRTY
TRANSFORMER
TANK NUMBER 2
OIL RECEIVING
BREAKER
TANK NUMBER 3
TANK NUMBER 6B
TANK NUMBER 6A
LUB OIL CLEAN
NUMBER 5
TANK
LUB OIL CLEAN
NUMBER 4
TANK
SEE NOTE 2
SEE NOTE 4
(SEE NOTE 1)
NOTES:
AND PLATFORM SUSPENSION MEMBERS, AND SHIP LADDERS.
4. REMOVE EXISTING WALKWAYS AND PLATFORMS, WALKWAY
WITH TANKS 4, 5 AND 6.
3. REMOVE ALL PIPING INTERCONNECTING TANKS NO. 1, 2 AND 3
2. REMOVE PUMPS NO. 1, 2 AND 3 AND ALL ASSOCIATED PIPING.
AND BREAKER OIL PIPING, AND WALKWAYS.
NO. 1, 2 AND 3 AND ALL ASSOCIATED TRANSFORMER
1. REMOVE ITEMS SHOWN IN BOLD INCLUDING TANKS
DRAWING PLOT SIZE: ANSI D
D
C
A
B
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R
/2
/2
BORDER VERSION UPDATE [09-2012]
MD002SHEET NAME:g2hdcgp9 MSTforACAD-V8i-IntroBY USERNAME:DATE AND TIME PLOTTED: 10/21/2019 11:32:00 AM of Engineers
US Army Corps
A D
V E
R T
IS
E U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D D
IS
T R
S
N N
E V
IL
L E L
O C
K A
N D D
E P
R O
T E
C T
IO
N
R
V A
U G
H N
S L
O R
E N
Z
J
IM
B
R U
N O
T
P O
R T
L A
N D
O R
E G
O N
F
IR
S T P
O W
E R
H O
U S
E
O
IL
S
T O
R A
G E R
O O
M
S H
E E
T
D E
M O
L
IT
IO
N
B D
P .1
M D
.d g n
R S
T R
IN
G F
E L L
O W
W
N
B
MD1002
/2
OIL STORAGE ROOM - MODIFIED
DRAWING PLOT SIZE: ANSI D
D
C
A
B
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R
/2
/2
BORDER VERSION UPDATE [09-2012]
M1001SHEET NAME:g2hdcgp9 MSTforACAD-V8i-IntroBY USERNAME:DATE AND TIME PLOTTED: 10/21/2019 11:32:01 AM of Engineers
US Army Corps
A D
V E
R T
IS
E U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D D
IS
T R
S
N N
E V
IL
L E L
O C
K A
N D D
E P
R O
T E
C T
IO
N
M1001
R
V A
U G
H N
S L
O R
E N
Z
J
IM
B
R U
N O
T
N E
W A
R R
A N
G E
M E
N T
O
IL
S
T O
R A
G E R
O O
M P
O R
T L
A N
D
O R
E G
O N
F
IR
S T P
O W
E R
H O
U
D
P .1
M .d g n
SCALE: NOT TO SCALE
WITH THE PURIFIER OUTSIDE OF THE OIL STORAGE ROOM.
TO OIL TANKS NO. 4, 5 AND 6 TO DUPLICATE EXISITNG FUNCTIONALITY
RELOCATE EXISTING PALL HVP-903-2703 OIL PURIFIER AND RECONNECT
LOW HEADROOM 1 TON HOIST AND LOW HEADROOM OIL DRUM LIFTER.
DESIGN, FURNISH AND INSTALL NEW MONORAIL BEAM AND SUPPORTS,
FOR THE ENTRY STAIRWAY TO THE OIL STORAGE ROOM.
DESIGN, FURNISH AND INSTALL NEW OIL DRUM TROLLEY AND GUIDES
STAIRWAYS AND SUPPORTS.
DESIGN, FURNISH AND INSTALL NEW WALKWAYS, PLATFORMS, HANDRIAILS,
4.
3.
2.
1.
R S
T R
IN
G F
E L L
O W
W
N
B
/2
N O
M
IN
A L F
IE
L D V
E R
IF
Y
72" NOMINAL (FIELD VERIFY)
NEW MONORAIL BEAM
EL. 28.68
NEW 1 TON LOW HEADROOM ELECTRIC CHAIN HOIST
NEW LOW HEADROOM OIL DRUM LIFTER
OIL DRUM, 55 GALLON
NEW SAFETY CHAIN
NEW OIL DRUM TROLLEY
STAIRWAYS
SUPPORTS, PLATFORMS AND
NEW WALKWAYS, HANDRAILS,
(FIELD VERIFY)
48" NOMINAL
STAIRWAY WIDTH
EXISTING STAIRWAY
(FIELD VERIFY)
EL. 27 NOMINAL
IN THE GUIDE TRACK
PAIRS OF WHEELS MUST STAY
FURTHER THAN SHOWN. TWO
TROLLEY FROM TRAVELLING
TROLLEY STOP MUST PREVENT
NEW GUIDE TRACK
EL. 23.5
T Y
P
IC
A L
DRAWING PLOT SIZE: ANSI D
D
C
A
B
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R
/2
/2
BORDER VERSION UPDATE [09-2012]
M1002SHEET NAME:g2hdcgp9 MSTforACAD-V8i-IntroBY USERNAME:DATE AND TIME PLOTTED: 10/21/2019 11:32:44 AM of Engineers
US Army Corps
A D
V E
R T
IS
E U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D D
IS
T R
S
N N
E V
IL
L E L
O C
K A
N D D
E P
R O
T E
C T
IO
N
M1002
R
V A
U G
H N
J
IM
B
R U
N O
T
O
IL
S
T O
R A
G E R
O O
M
F
IR
S T P
O W
E R
H O
U S
E
P O
R T
L A
N D
O R
E G
O N
N E
W A
R R
A N
G E
M E
N T S
E C
T
IO
SECTION THROUGH STAIRWELL
D
P .1
M .d g n
SCALE: NOT TO SCALE
R S
T R
IN
G F
E L L
O W
W
N
B
D
R U
S
/2
PLAN EL - 10.00
RELIEF
RELIEF RELIEF
OIL STORAGE ROOM - PORTABLE PUMP
PUMPING FROM TANK 6B TO EL. 55 TAILRACE DECK
ALTERNATIVELY, COULD CONNECT HOSE FOR GRAVITY DRAIN TO TANK 6B
PUMPING FROM TRANSFORMERS OR BREAKERS TO TANK 6B
NOTES:
EXISTING FLOOR.
AND PUMPS NO. 1, 2 AND 3. CUT AND GRIND BASES FLUSH TO THE
REMOVE EXISTING CONCRETE AND GROUT BASES FOR TANKS NO. 1, 2 AND 3
DEMOLITION.
WELD PIPE CAPS TO ALL OPEN PIPE ENDS WHICH RESULT FROM PIPE
TANKS 4, 5 AND 6.
REMOVE PIPING WHICH INTERCONNECTS TANKS NO. 1, 2 AND 3 TO
REMOVE PUMPS NO. 1, 2 AND 3 AND ASSOCIATED PIPING.
AND RETURN PIPING BETWEEN OIL STORAGE ROOM AND TRANSFORMER.
REMOVE ALL NON-EMBEDDED TRANSFORMER AND BREAKER OIL SUPPLY
UP TO THE POINT WHERE PIPE IS EMBEDDED.
IN OIL STORAGE ROOM FOR FOR TRANSFORMER OIL AND BREAKER OIL
REMOVE EXISTING OIL TANKS NO. 1, 2 AND 3 AND ALL ASSOCIATED PIPE
6.
5.
4.
3.
2.
1.
DRAWING PLOT SIZE: ANSI D
D
C
A
B
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R
/2
/2
BORDER VERSION UPDATE [09-2012]
M1003SHEET NAME:g2hdcgp9 MSTforACAD-V8i-IntroBY USERNAME:DATE AND TIME PLOTTED: 10/21/2019 11:32:45 AM of Engineers
US Army Corps
A D
V E
R T
IS
E
ONE-TO FIT ALL TANKS
" REMOVABLE PIPE CONNECTION2
" UNION2
VALVE
" GATE2
4"
4"
4" 4"
4"
2"
"2
TANK NO. 6A
CLEAN LUBE OIL
GAUGE
TEE FOR
4"
4"
2"
2"
2"
EL & 24'-8"
2" VENT
EL & 24'-8"
2" VENT
4"
4"
4"
4"
4"
2"
2"
4"
3"
3"
4"
OPEN END AT ELEV.+11'-0"
4" VENT OVERFLOW-DOWN
4" STRAP AT FLOOR
IN PLACE
FLOOR DRAIN
4" SUCTION FROM TANK 6A-EL. +10'-4"
"2
1" DRAIN HEADER EL. +10'-8 2
3" TO FILTER SUCTION- EL. +10'-4"
3" TO FILTER DISCH.- ELEV. +10'-4"
3" TO PUMP SUCTION- FROM TANK 5
FROM FILTER
3" LUBE OIL-DISCHARGE
3" TO PUMP SECTION
3" TO FILTER SECTION
6"
6"
6"
3" LUB. OIL SUPPLY
6" LUB. OIL DRAIN
3" LUB. OIL RETURN
6" OIL DRAIN FROM TRANSFORMERS & BREAKERS
3" OIL SUPPLY TO TRANSFORMERS & BREAKERS
3" OIL RETURN FROM TRANSFORMERS & BREAKERS
1" WATER 1" COMP. AIR
GENERAL SERVICE
6"
SCALE 3/8" = 1'-0"
NUMBER 6B
TANK
NUMBER 5
TANK
NUMBER 4
TANK
LUBE OIL-RECEIVING
4"
4"
3"
3"
6"
6"
6"
3" OIL RETURN FROM TRANSFORMERS & BREAKERS
DECK
TAILRACE
TO EL. 55
PUMP SKID
PORTABLE
NEW
PUMP SKID
PORTABLE
NEW
RELIEF
6B
FROM TANK TO TANK 6B
RELIEF
TYP.
CONNECTION,
COUPLE
QUICK
CONNECT
DRY
TYP.
CONNECTION,
COUPLE
QUICK
CONNECT
DRY
TYP.
CONNECTION,
COUPLE
QUICK
CONNECT
DRY
TYP.
CONNECTION,
COUPLE
QUICK
CONNECT
DRY
DECK
TAILRACE
TO EL. 55
1 1/2" HOSE
1 1/2" HOSE
1 1/2" HOSE
3/4" HOSE
1 1/2" HOSE
3/4" HOSE
NOTE: NEW WALKWAY AND STAIR NOT SHOWN FOR CLARITY
NOTE: NEW WALKWAY AND STAIR NOT SHOWN FOR CLARITY
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D D
IS
T R
S
N N
E V
IL
L E L
O C
K A
N D D
E P
R O
T E
C T
IO
N
R
V A
U G
H N
J
IM
B
R U
N O
T
P O
R T
L A
N D
O R
E G
O N
F
IR
S T P
O W
E R
H O
U S
E
O
IL
S
T O
R A
G E R
O O
M
B D
P .1
M .d g n
M1003
S L
O R
E
Z
R
T A
B L E P
U M
P A
R R
A N
G E
M E
N T
R S
T R
IN
G F
E L L
O W
W
N
B
/2
EL +23.50
TANK #4
REFERENCE DRAWINGS:
PUMP #5
UTILITY HATCH
CHASE
PIPE
PLAN - OIL STORAGE ROOM AT EL +10.00
PLAN AT EL +23.50
80'-0"
51'-3"
NOTES:
NO 2
ELEVATOR
1 CQ-4
AC PANEL
1 CR-1
AC PANEL OIL VACUUM PURIFIER SKID
PUMP #3
PUMP #2
PUMP #1
SEE NOTE 2
40'-0"
SEE NOTE 3
DOWN
SEE NOTE 2
TANK #5TANK #6A TANK #3 TANK #1
(SEE NOTE 4)
TANK #2
1 CQ1
AC PANEL
DOWN
SEE NOTE 2
PUMP CONTROL STATION
PLAN - OIL PURIFIER ROOM AT EL -26.00
EL +10.00
1.
2.
3.
4.
5.
6.
DRAWING IS NOT TO SCALE.
UPDATE PANEL SCHEDULE.
ALL CONDUIT AND WIRES BACK TO PANEL 1-CQ1.
REMOVE RECEPTACLE FOR RELOCATION. REMOVE
TO WORK IN THE EXISTING ANNUNICATION PANEL EL +77.00.
CONTRACTOR SHALL COORDINATE WITH USACE PRIOR
DEBRIS ARE REMOVED.
MAY BE REUSED AFTER BURRS, SHARP EDGES AND
IF APPROVED BY USACE, EMPTY EXISTING CONDUITS
P-12-16 STATION SERVICE UNIT EL +23.5, 10.0 & 3.0
P-10-53 TRANSVERS SECTION AT STATION SERVICE UNIT.
7.
(SEE NOTE 7)
UPDATE PANEL SCHEDULE.
FOR PUMPS 1-4 AND 6. REMOVE ALL EXPOSED CONDUITS.
CONTROL STATIONS AND WIRE BACK TO THE PANEL 1-CQ4
REMOVE PUMPS 1, 2 AND 3 AS INDICATED. REMOVE
DETAILS IN SECTION 33.52.10.01 PARAGRAPH 3.1.1.
MANUFACTURER'S REPRESENTATIVE. ADDITIONAL
MUST BE DONE UNDER THE DIRECTION OF THE PALL
EL +10.00. DISASSEMBLY, REASSEMBLY, AND TESTING
RELOCATE OIL PURIFIER TO OIL STORAGE ROOM
TO PROCEED UPON USACE APPROVAL.
CY PANEL. CONTRACTOR WIRE REMOVAL FROM CY PANEL
SHEET E1004. USACE TO PERFORM ALL WORK WITHIN
(EL. +37.00) APPROXIMATELY 450' AWAY, AS SHOWN ON
ALL CONNECTIONS BACK TO CO2 SYSTEM #1 PANEL CY
FROM WITHIN THE OIL STORAGE ROOM AND REMOVE
COORDINATE WITH USACE TO REMOVE ALL CO2 DEVICES
DRAWING PLOT SIZE: ANSI D
D
C
A
B
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R
/2
/2
BORDER VERSION UPDATE [09-2012]
ED1001SHEET NAME:g2hdcgp9 MSTforACAD-V8i-IntroBY USERNAME:DATE AND TIME PLOTTED: 10/21/2019 11:32:47 AM of Engineers
US Army Corps
A D
V E
R T
IS
E U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D D
IS
T R
S
N N
E V
IL
L E L
O C
K A
N D D
A M
B
B E
N S
O N
S L
O R
E N
Z
J
IM
B
R U
N O
T
F
IR
S T P
O W
E R
H O
U S
E
O
IL
S
T O
R A
G E R
O O
M P
O R
T L
A N
D
O R
E G
O N
F
IR
E P
R O
T E
C T
IO
N
E L E
C T
R
IC
A L
N
B D
P .1
E
D .d g n
P O
W E
R D
E M
O L
IT
IO
N
N N
B
B E
N S
O N
W
N
B
ED1001
/2
DRAWING PLOT SIZE: ANSI D
D
C
A
B
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R
/2
/2
BORDER VERSION UPDATE [09-2012]
E1001SHEET NAME:g2hdcgp9 MSTforACAD-V8i-IntroBY USERNAME:DATE AND TIME PLOTTED: 10/21/2019 11:32:47 AM of Engineers
US Army Corps
A D
V E
R T
IS
E U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D D
IS
T R
S
N N
E V
IL
L E L
O C
K A
N D D
A M
E1001
B B
E N
S O
N
S L
O R
E N
Z
J
IM
B
R U
N O
T
F
IR
S T P
O W
E R
H O
U S
E
O
IL
S
T O
R A
G E R
O O
M
F
IR
E P
R O
T E
C T
IO
N P
O R
T L
A N
D
O R
E G
O N
F
IR
E S
U P
P R
E S
S
IO
N E
L E
C T
R
IC
A
LNOTES:
2.
1.
LEGEND:
* = EXISTING EQUIPMENT
3.
C A
B L E C
O N
D U
IT
4.
B D
P .1
E .d g n
AND CONDUIT ROUTING AND LENGTHS.
CONTRACTOR IS RESPONSIBLE FOR FINAL CABLE
STARTERS AS INDICATED IN THE SCHEDULE.
TO PROVIDE BREAKERS AND COMBINATION MOTOR
REQUIRED FOR THE SYSTEM PROVIDED. CONTRACTOR
CABLE AND CONDUIT IN THE SIZE AND QUANTITY AS
CONTRACTOR SHALL FURNISH AND INSTALL POWER
PROVIDE A COMPLETE FIRE SUPPRESSION SYSTEM.
DEVICES FURNISHED IN THIS CONTRACT TO
SCHEDULE AND ALSO BETWEEN FIRE SUPPRESSION
ALL CABLE AND CONDUIT LISTED IN THE
CONTRACTOR SHALL FURNISH AND INSTALL
B
B E
N S
O N
W
N
B
PROVIDED WITH THIS CONTRACT.
INCLUDING WIRING FOR ALL OF THE DEVICES
COMPLETED CABLE AND CONDUIT SCHEDULE
DRAWINGS. CONTRACTOR SHALL SUBMIT A
FOR ADDITIONAL DEVICES SEE FIRE PROTECTION
THE DEVICES FURNISHED UNDER THIS CONTRACT.
EQUIPMENT ONLY AND DOES NOT INCLUDE ALL OF
AND ALARM INTERFACE WITH THE EXISTING PLANT
CABLE AND CONDUIT LISTED FOR POWER, CONTROL
S C
H E
D U
L E S
H E
E T
/2
DRAWING PLOT SIZE: ANSI D
D
C
A
B
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R
/2
/2
BORDER VERSION UPDATE [09-2012]
E1002SHEET NAME:g2hdcgp9 MSTforACAD-V8i-IntroBY USERNAME:DATE AND TIME PLOTTED: 10/21/2019 11:33:07 AM of Engineers
US Army Corps
A D
V E
R T
IS
E U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D D
IS
T R
S
N N
E V
IL
L E L
O C
K A
N D D
A M
E1002
B B
E N
S O
N
S L
O R
E N
Z
J
IM
B
R U
N O
T
F
IR
S T P
O W
E R
H O
U S
E
O
IL
S
T O
R A
G E R
O O
M
F
IR
E P
R O
T E
C T
IO
N P
O R
T L
A N
D
O R
E G
O N
F
IR
E S
U P
P R
E S
S
IO
N E
L E
C T
R
IC
A
LNOTES:
2.
1.
LEGEND:
* = EXISTING EQUIPMENT
3.
C A
B L E C
O N
D U
IT
4.
B D
P .1
E .d g n
AND CONDUIT ROUTING AND LENGTHS.
CONTRACTOR IS RESPONSIBLE FOR FINAL CABLE
B
B E
N S
O N
W
N
B
WITH THIS CONTRACT.
WIRING FOR ALL OF THE DEVICES PROVIDED
CABLE AND CONDUIT SCHEDULE INCLUDING
CONTRACTOR SHALL SUBMIT A COMPLETED
PROVIDED.
QUANTITY AS REQUIRED FOR THE SYSTEM
CABLE AND CONDUIT IN THE SIZE AND
CONTRACTOR SHALL FURNISH AND INSTALL
COMPLETE FIRE SUPPRESSION SYSTEM.
FURNISHED IN THIS CONTRACT TO PROVIDE A
AND ALSO BETWEEN FIRE SUPPRESSION DEVICES
CABLE AND CONDUIT LISTED IN THE SCHEDULE
CONTRACTOR SHALL FURNISH AND INSTALL ALL
S C
H E
D U
L E S
H E
E T
/2
UTILITY…