AM04.pdf

PDF 227 KB Posted

Attached to
UNACCOMPANIED ENLISTED PERSONNEL HOUSING, SOTO CANO AIR BASE, HONDURAS
Solicitation number
W9127819R0028
Issued by

About this file

Amendment 0004

View the file

Other files

File Type Posted
AM05.pdf PDF
AM05-DRAWINGS.pdf PDF
AM01.pdf PDF
AM04-DRAWINGS.pdf PDF
AM03.pdf PDF
AM03-DRAWINGS.pdf PDF
AM02-DRAWINGS.pdf PDF
W9127819R0028_AM02_Amendment.pdf PDF
VOL2.PDF PDF
EM_385-1-1.pdf PDF
DRAWINGS.pdf PDF
VOL3.PDF PDF
VOL1.PDF PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES

1 2

2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE 5. PROJECT NO. (If applicable)

W9127819R0028-0004 12 APRIL 2019 M017EU44

6. ISSUED BY CODE 7. ADMINISTERED BY(If other than item 6)

CODE

Corps of Engineers 109 St. Joseph St.

Mobile, AL 36602

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP code) 9A. AMENDMENT OF SOLICITATION

NO.

W9127819R0028

9B. DATED (SEE ITEM 11)

15 MARCH 2019

10A. MODIFICATION OF

CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

CODE FACILITY CODE

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in item 14. The hour and date specified for receipt of Offers is extended, is not extended. Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods: (a) By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (if required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority)

THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO AUTHORITY OF FAR 43.103(b)

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible)

The subject solicitation for: UNACCOMPANIED ENLISTED PERSONNEL HOUSING, SOTO CANO AIR BASE, HONDURAS Is modified in the following: REFER TO THE ENCLOSED REVISED SPECIFICATIONS AND DRAWINGS FOR AMENDMENT NO. 0004.

Except as provided herein, all terms and conditions of the document reference in item 9A or 10A, as Heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICE (Type or print)

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA

BY

(Signature of contracting officer)

16C. DATE SIGNED

NSN 7540-01-152-8070 30-105 STANDARD FORM 30 (REV. 10-83)

PREVIOUS EDITION UNUSABLE Prescribed by GSA

UNACCOMPANIED ENLISTED PERSONNEL HOUSING W9127819R0028

SOTO CANO AIR BASE, HONDURAS M017EU44

SF 30 Page 2 W9127819R0028-0004

PART I - REVISIONS MADE BY ADDED AND/OR REPLACEMENT PARAGRAPHS/PAGES/SECTIONS

The items listed below are to be replaced by the corresponding added and/or revised paragraphs/pages or sections. Added and/or revised paragraphs/pages or sections are indicated by a note in bottom right hand corner of each paragraph or page. Added sections are hereby made a part of the contract and are to be inserted in the specification in the proper numerical/alphabetical sequence.

Within the specifications, deletions from the specifications are indicated by strikethrough, e.g.: deletions are marked with strikethrough and additions to the specifications including revisions/substitutions are indicated in bold, italic and underlined, e.g.: additions are indicated thus.

Corresponding Added or Revised Paragraph SECTION Page, and/or Section

00 11 00 Revised Paragraphs 3.2 and 4.5.1(c) as indicated herein.

05 42 50 Revised Paragraphs 2.1, 2.2 and 2.3 as indicated herein.

21 13 13.00 10 Revised Paragraph 3.3 as indicated herein.

26 12 19 Revised Paragraph 2.2.4 as indicated herein.

26 13 01 Revised Paragraph 2.1.2.1 as indicated herein.

26 51 00 Added Paragraph 2.5.4 as indicated herein.

28 31 76 Added Paragraph 2.19.1.2 as indicated herein.

Deleted Paragraphs 2.19.2 and 2.19.3

PART II - Revised drawings are listed below. These revised drawings are to be inserted into the folio in the proper numerical sequence. Drawings that have been revised or replaced by this amendment shall be deleted from the folio.

All drawings listed below are revised unless indicated otherwise.

SHEET

REF. TITLE OF DRAWINGS

COVER SHEET

S-001 GENERAL STRUCTURAL NOTES, DESIGN LOADS & ABBREVIATIONS

ES501 ELECTRICAL DISTRIBUTION DETAILS

EP601 ELECTRICAL RISER DIAGRAM

ET503 TELECOMMUNICATION SYSTEMS DETAILS

ET601 TELECOMMUNICATION SYSTEMS RISER DIAGRAM

Encl as stated Revised pages of the specifications as indicated in Part I.

6 Revised drawings as indicated in Part II.

00 11 00 Revised by Amendment No. W9127819R0028-0004

00 11 00

3.2 Submit the proposals in two separate volumes, labeled with quantities as follows:

Submit two (2) electronic copies of “Volume I - Non-Priced Evaluation Factors” in Portable Document File (PDF) format on compact disk (CD).

Place the CDs in an envelope clearly marked on the outside “Volume I - Non-Priced Evaluation Factors”.

Submit two (2) electronic copies of the entire proposal (Volumes I and II) in Portable Document File (PDF) format on compact disk (CD). Place the CDs in an envelope clearly marked on the outside “Volumes I and II”.

Bid bonds must be submitted in original hardcopy with the proposal package. Other than bid bonds, Hard copies of Volumes I and II are not required to be submitted, and will not be accepted or evaluated.

However, when formatting the PDF files the page size should be 8-1/2” x 11” for all pages except schedules which should be 11” x 17”.

4.5.1 The Offeror is to submit the following information: (1) Standard Form 1442, proposal data sheet (attachment 1), and acknowledgement of all amendments (2) proposal bid schedules, (3) representations and certification, and (4) most recent Financial Statement. In Volume II, Offerors shall also submit the required pre-award information, which includes but is not limited to:

(a) A list of present commitments, including the dollar value thereof.

Include names and telephone numbers of personnel within the organization who are familiar with company’s performance. For a newly formed Joint Venture (JV), each JV partner must submit a list of present commitments.

(b) The bid on this solicitation exceeds $1,000,000.00; therefore, the Offeror shall also submit a certified statement listing: (1) each contract awarded to the Offeror within the preceding three month period exceeding $1,000,000.00 in value with a brief description of the contract; and (2) each contract awarded to the Offeror within the preceding three year period not already physically completed and exceeding $5,000,000.00 in value with a brief description of the contract.

(c) Bid Bonds as required by Section 00 70 00. Bid bonds must be submitted in original hardcopy as indicated in paragraph and subparagraphs 3.0 of this section.

(NOTE: The remainder of the section is unchanged by the amendment.)

This page was intentionally left blank for duplex printing.

05 42 50 Revised by Amendment No. W9127819R0028-0004

05 42 50

2.1 ACCEPTABLE MANUFACTURERS

Pre-Engineered, Cold-Formed Steel Trusses:

1. Base: Alpine Engineered Products, Inc., "TrusSteel Truss System".

2. Optional: Dietrich Industries, "Ultra-Span Truss System".

Other manufacturers desiring approval comply with Section 01 33 00.

Manufacturers meeting certification requirements set forth in Section 1.2 of this specification.

2.2 TRUSS MEMBERS

ASTM A 653/A 653M (230 MPa minimum yield stress) with Z180 G60 (Z180) galvanized zinc coating.

Minimum uncoated steel thickness:

1. Top Chords: 1.21 mm. 18 gage.

2. Bottom Chord: 1.44 mm. 16 gage.

2 3. Webs: 0.91 mm. 20 gage (Structural).

Mechanical Testing of steel products per ASTM A 370.

2.3 BRACING, BRIDGING, AND BLOCKING MEMBERS

ASTM A 653/A 653M (230 MPa minimum yield stress) with Z180 G60 (Z180) galvanized zinc coating.

Minimum uncoated steel thickness, unless noted otherwise: 0.91 mm. 20 gage (Structural).

21 13 13.00 10 Revised by Amendment No. W9127819R0028-0004

21 13 13.00 10

3.3 INSPECTION BY FIRE PROTECTION SPECIALIST

Prior to ceiling installation and concurrent with the Final Acceptance Test Report, certification by the Fire Protection Specialist that the sprinkler system is installed in accordance with the contract requirements, including signed approval of the Preliminary and Final Acceptance Test Reports. The Fire Protection Specialist shall: 1) inspect the sprinkler system periodically (at least once per month) during the installation to assure that the sprinkler system is being provided and installed in accordance with the contract requirements, 2) witness the preliminary and final tests, and sign the test results, 3) after completion of the system inspections and a successful final test, certify in writing that the system has been installed in accordance with the contract requirements. Any discrepancy shall be brought to the attention of the Contracting Officer in writing, no later than three working days after the discrepancy is discovered.

26 12 19 Revised by Amendment No. W9127819R0028-0004

26 12 19

2.2.4 Corrosion Protection

Provide corrosion resistant bases and cabinets of transformers, fabricated of stainless steel conforming to ASTM A240/A240M, Type 304 or 304L. Base includes any part of pad-mounted transformer that is within 75 mm of concrete pad.

Paint entire transformer assembly Munsell 7GY3.29/1.5 green, with paint coating system complying with IEEE C57.12.28 and IEEE C57.12.29 regardless of base, cabinet, and tank material. The Munsell color notation is specified in ASTM D1535.

26 13 01 Revised by Amendment No. W9127819R0028-0004

26 13 01

2.1.2.1 Pad-mounting Provisions

Provide enclosed switchgear suitable for installation on a concrete pad, including the following:

a. Fabricate switchgear enclosure and enclosure base of ASTM A167 type 304 or 304L stainless steel.

a b. Enclosure base includes any part of the switchgear enclosure that is within 75 mm of concrete pad.

b c. Paint enclosure including base ASTM D1535 Munsell 7GY3.29/1.5 green.

c d. Comply with IEEE C57.12.28 for the paint coating system regardless of equipment material.

26 51 00 Revised by Amendment No. W9127819R0028-0004

26 51 00

2.5.4 Local Area Lighting Controller

CEC Title 24 and ASHRAE 90.1 - IP compliant. Provide controller designed for single area or room with the following requirements:

a. 120 volt input, designed for LED lighting loads.

b. 2 zone, with 1 relay rated 20 amps.

c. Inputs for occupancy sensor, photocell, and low-voltage wall switch.

28 31 76 Revised by Amendment No. W9127819R0028-0004

28 31 76

2.19.1.2 Licensed Radio Frequency Systems

An approved DD Form 1494 for the system is required prior to operation.

2.19.2 Telephone

A modem shall be provide for communication with the Central Control/Monitoring System. The modem shall be 56k, compatible with data mode V.90, utilizing Hayes compatible command codes. The modem shall be capable of Auto dialing a preset number based on preprogrammed events. The modem shall auto answer and provide a secure password protection system.

Cabling: as specified in Section 27 10 00 BUILDING TELECOMMUNICATIONS

CABLING SYSTEM.

2.19.3 Secure Radio System

2.19.3.1 Communications Network

The communications network provides two-way signals between central control units and autonomous control units (in individual building systems), and should include redundant (primary and backup) communication links. The system shall incorporate technology to prevent easy interruption of the radio traffic for MNS Alerting.

2.19.3.2 Radio Frequency Communications

Use of radio frequency-type communications systems shall comply with National Telecommunications and Information Administration (NTIA) requirements. The systems shall be designed to minimize the potential for interference, jamming, eavesdropping, and spoofing.

2.19.3.3 Licensed Radio Frequency Systems

An approved DD Form 1494 for the system is required prior to operation.

SF30
Section 00 11 00 revisions
Section 05 42 50 revisions
Section 21 13 13.00 10 revisions
Section 26 12 19 revisions
Section 26 13 01 revisions
Section 26 51 00 revisions
Section 28 31 76 revisions

File details come from the government source that posted it.