AM02-DRAWINGS.pdf

PDF 2 MB Posted

Attached to
UNACCOMPANIED ENLISTED PERSONNEL HOUSING, SOTO CANO AIR BASE, HONDURAS
Solicitation number
W9127819R0028
Issued by

About this file

AM02 Drawing

View the file

Other files

File Type Posted
AM05.pdf PDF
AM05-DRAWINGS.pdf PDF
AM01.pdf PDF
AM04.pdf PDF
AM04-DRAWINGS.pdf PDF
AM03.pdf PDF
AM03-DRAWINGS.pdf PDF
W9127819R0028_AM02_Amendment.pdf PDF
VOL2.PDF PDF
EM_385-1-1.pdf PDF
DRAWINGS.pdf PDF
VOL3.PDF PDF
VOL1.PDF PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers

MOBILE DISTRICT

109 SAINT JOSEPH STREET

MOBILE AL 36602

MOBILE DISTRICT PROJECT CODE :

SOLICITATION NUMBER :

UNACCOMPANIED ENLISTED

PERSONNEL HOUSING

SOTO CANO AIR BASE, HONDURAS

M017EU44

W9127819R0028

MARCH 2019 AMENDMENT NO. 0002

A B C

C1

D

SCALE: NTS SCALE: NTS SCALE: NTS

SCALE: NTS

WALL TYPE WALL TYPE WALL TYPE

WALL TYPE

METAL STUD TO

BOTTOM OF

STRUCTURE

LINE OF CEILING 16 GYPSUM WALLBOARD

{ABUSE RESISTANT PANELS

16 CEMENT BACKER BOARD BEHIND

CERAMIC TILE ONLY}

METAL

STUDS LINE OF FLOOR

ACOUSTICAL SEALANT

SOUND

INSULATION

LINE OF STRUCTURAL

FLOOR OR ROOF DECK FIRE STOP

200 CONCRETE

MASONRY UNIT

LINE OF FLOOR

HORIZ JOINT

REINFORCING

CEILING AS SCHEDULED

FIRE RATING: 1 HR FR

60 METAL

STUDS EA. SIDE

200 CONCRETE

MASONRY UNIT

LINE OF FLOOR

GROUT FULL

HORIZ JOINT

REINFORCING

FIRE RATING: 1 HR FR FIRE RATING: NOT RATED

150 METAL STUD

LINE OF STRUCTURE

GROUT FULL

LINE OF

STRUCTURAL

DECK

METAL STUD TO BOTTOM

OF STRUCTURE

LINE OF CEILING

16 FIRE RATED GYPSUM

WALLBOARD

100 METAL CEE STUDS

LINE OF FLOOR

FIRE RATED SEALANT

SOUND INSULATION

GENERAL NOTES:

1.

SEE ROOM FINISH SCHEDULE FOR SPECIAL

FINISHES ON CONCRETE MASONRY UNITS.

3.

SEE PLANS FOR FIRE RATED WALL LOCATIONS AND HOURLY

RATED REQUIREMENTS.

4.

SEE STRUCTURAL FOR ALL VERTICAL WALL REINFORCING AND

ALL BOND BEAM REINFORCING IN MASONRY WALLS AND FOR

ALL REINFORCING IN CIP CONCRETE WALLS.

5.

PROVIDE ACOUSTICAL SEALANT AT WALL TYPES

INDICATED TO RECEIVE SOUND INSULATION.

6.

PROVIDE FIRE STOPPING AND FIRE RATED SEALANT AS

REQUIRED FOR ASSEMBLY INDICATED AT FIRE RATED WALLS.

7.

SEE PLANS FOR WALL THICKNESS NOT SHOWN ON THIS

DRAWING.

8.

PROVIDE CEMENT BACKER BOARD WHERE CERAMIC TILE IS

INDICATED IN LIEU OF GYPSUM BOARD WHERE WALL IS

SCHEDULED TO RECEIVE CERAMIC TILE FINISH, UNLESS NOTED

OTHERWISE FOR SPECIFIC WALL TYPE.

PROVIDE IMPACT RESISTANT PANELS IN LIEU OF GYPSUM

BOARD WHERE SCHEDULED.

NOTE

1. PROVIDE 19 EXTERIOR GRADE SHEATHING

AT EXTERIOR WALLS.

2. PROVIDE CONTINIOUS FIRE RATING BETWEEN

TRUSSES AS REQUIRED.

LINE OF STRUCTURAL

FLOOR OR ROOF DECK FIRE STOP

B1

SCALE: NTS

WALL TYPE

60 METAL

STUDS

LINE OF FLOOR

GROUT FULL

150 METAL

STUDS

200 CONCRETE

MASONRY UNIT

FIRE RATING: 1 HR FR

C2

SCALE: NTS

WALL TYPE

METAL STUD TO

BOTTOM OF

STRUCTURE

LINE OF CEILING

16 GYPSUM WALLBOARD

ABUSE RESISTANT PANELS

BEDROOM SIDE

100 METAL

STUDS

LINE OF FLOOR

ACOUSTICAL SEALANT

SOUND

INSULATION

LINE OF STRUCTURE

CHASE WALL

SCALE: NTS

WALL TYPE

LINE OF STRUCTURAL

FLOOR OR ROOF DECK FIRE STOP

200 CONCRETE

MASONRY UNIT

LINE OF FLOOR

HORIZ JOINT

REINFORCING

CEILING AS SCHEDULED

FIRE RATING: 1 HR FR

GROUT FULL

E

3 COAT STUCCO SYSTEM ON LATH

OVER FLUID APPLIED VAPOR BARRIER

16 GYPSUM

WALLBOARD

ABUSE RESISTANT

PANELS

BEDROOM SIDE

16 GYPSUM

WALLBOARD

ABUSE RESISTANT

PANELS

BEDROOM SIDE

16 GYPSUM

WALLBOARD

ABUSE RESISTANT

PANELS

BEDROOM SIDE

16 GYPSUM

WALLBOARD

ABUSE RESISTANT

PANELS

BEDROOM SIDE

60 METAL

STUDS/FURRING

16 GYPSUM

WALLBOARD

ABUSE RESISTANT

PANELS

BEDROOM SIDE

60 RIGID

INSULATION R19

FIRE RATING: 1 HR FR

DAMPPROOFING THIS SIDE

(MECH., ELEC. ROOM

60 METAL

STUDS/FURRING

STUCCO SYSTEM, METAL LATH

WITH SELF ADHERED MEMBRANE

60 RIGID

INSULATION R19

60 RIGID

INSULATION R19

US Army Corps of Engineers

SHEET ID

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

PR

O

JE

C

T N

U M

BE

R

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D

ES

C R

IP

TI

O N

A-601

U N

AC

C

O M

PA

N

IE

D

E N

L I

ST

ED

P

ER

SO

N N

EL

H

O U

SI

N

G M

O B I

LE

D

IS

T R

IC

T

T.

D

.W

T.

D

.W

C .A

J.

M

.C

FE

BR

U

AU

R Y

W

9R

M

7E U

M

7E C

AMENDMENT 0002

SO

TO

C

AN

O A

IR

B

AS

E, H O

N D

U R

AS

M O

BI

LE

, A

LA

BA

M

A

W

AL

L

TY

P E S

M

AR

K D

AT

E

AM

EN

D

M

EN

T

/2

8/

C

H

AN

G

ED

W

AL

L

TY

PE

D

ET

AI

LS

A

AS

S

C H

ED

U

LE

D

AS

SCHED

AS

S

C H

ED

U

LE

D

AS

SCHED

M

FR

ST

D

MFR

STD

AS

S

C H

ED

U

LE

D

AS

SCHED 10

AS

S

C H

ED

U

LE

D

AS

SCHED 50

DOOR TYPES DOOR FRAMES

WINDOW TYPES

F N 100x625 1 2

INSULATED GLAZING UNIT, SEE

GLAZING SPEC. 08 81 00.

FIRE GLASS @ FIRE

RATED ASSEMBLY, SEE

GLAZING SPEC. 08 81 00

A

MANUF. CAM

HARDWARE

LOCK

US Army Corps of Engineers

SHEET ID

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

PR

O

JE

C

T N

U M

BE

R

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D

ES

C R

IP

TI

O N

A-603

U N

AC

C

O M

PA

N

IE

D

E N

L I

ST

ED

P

ER

SO

N N

EL

H

O U

SI

N

G M

O B I

LE

D

IS

T R

IC

T

T.

D

.W

T.

D

.W

C .A

J.

M

.C

FE

BR

U

AU

R Y

W

9R

M

7E U

M

7E C

AMENDMENT 0002

SO

TO

C

AN

O A

IR

B

AS

E, H O

N D

U R

AS

M O

BI

LE

, A

LA

BA

M

A

FI

R

ST

F

LO

O

R D

O O

R S

C H

ED

U

L E

USACE_DOOR SCHEDULE FIRST FLOOR

DOOR NO. TYPE

DOOR

FIRE

RATING HARDWARE

FRAME

COMMENTS:

SIZE

MATERIAL FINISH TYPE MATERIAL FINISH

DETAILS

WIDTH HEIGHT THICKNESS HEAD JAMB SILL

101 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

102 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

103 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

104 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

105A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 105B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT

106 A 350 500 50 STEEL PAINTED 1/2HR - STEEL PAINTED - - - CAM LOCK BY MANUF.

107 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

108 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

109 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

110 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

111A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 111B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT

112 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL PAINTED - - - CAM LOCK BY MANUF.

113 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

114 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

115 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

116A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 116B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT

117 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

118 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL PAINTED - - - CAM LOCK BY MANUF.

119 F 900 2,100 50 HM PAINTED 1/2HR HW-1 1 HM PAINTED 1/A607 2/A607 8/A607

120 F 800 2,100 50 WD PAINTED 1/2HR HW-4 1 HM PAINTED 3/A607 4/A607 9/A607

121 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM PAINTED 3/A607 4/A607 9/A607

122 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

123 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

124 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

125 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

126A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 126B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT

127 A 350 500 50 STEEL PAINTED 1/2HR - STEEL PAINTED - - - CAM LOCK BY MANUF.

128 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

129 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

130 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

131 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

132A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 132B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT

133 A 350 500 50 STEEL PAINTED 1/2HR - STEEL PAINTED - - - CAM LOCK BY MANUF.

134 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

135 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

136 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

137 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

138A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 138B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT

139 A 350 500 50 STEEL PAINTED 1/2HR - STEEL PAINTED - - - CAM LOCK BY MANUF.

140A N 900 2,100 50 HM PAINTED 1/2 HR HW-2 1 HM PAINTED 1/A607 2/A607 7/A607

140B N 900 2,100 50 HM PAINTED 1/2 HR HW-2 1 HM PAINTED 1/A607 2/A607 7/A607

141 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL PAINTED - - - CAM LOCK BY MANUF.

142A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 142B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT

143 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

144 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

145 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

146 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

147 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL PAINTED - - - CAM LOCK BY MANUF.

148A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 148B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT

149 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

150 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

151 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

152 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED

153 A 350 500 50 STEEL PAINTED 1/2HR - STEEL PAINTED - - - CAM LOCK BY MANUF.

154 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

155 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

156 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

157 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

158A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 158B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT

159 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM PAINTED 3/A607 4/A607 9/A607

160 F 800 2,100 50 WD PAINTED 1/2HR HW-3 1 HM PAINTED 3/A607 4/A607 9/A607

161 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM PAINTED 3/A607 4/A607 9/A607

162 F 900 2,100 50 HM PAINTED 1/2HR HW-1 1 HM PAINTED 1/A607 2/A607 9/A607

163 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL PAINTED - - - CAM LOCK BY MANUF.

164 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

165 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

166 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

167 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

168A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 168B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT

169 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL PAINTED - - - CAM LOCK BY MANUF.

170 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

171 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

172 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

173 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

174A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 174B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT

175 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL PAINTED - - - CAM LOCK BY MANUF.

176 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

177 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

178 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607

179 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607

180A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 180B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT

USACE_DOOR SCHEDULE RISER ROOM

DOOR NO. TYPE

DOOR

FIRE

RATING HARDWARE

FRAME

COMMENTS:

SIZE

MATERIAL FINISH TYPE MATERIAL FINISH

DETAILS

WIDTH HEIGHT THICKNESS HEAD JAMB SILL

01 25 1,800 2,100 44 HM PAINTED 1 HM PAINTED FULLY LOUVERED

1 M

AR

K D

AT

E

AM

EN

D

M

EN

T

/2

8/

G R

ID

W

IN

D

O W

T

YP

E

AN

D D

O O

R C

O M

M

EN

T

S

C H

ED

U

LE

D

AS

SCHED

AS

S

C H

ED

U

LE

D

AS

SCHED

M

FR

ST

D

MFR

STD

AS

S

C H

ED

U

LE

D

AS

SCHED 10

AS

S

C H

ED

U

LE

D

AS

SCHED 50

DOOR TYPES DOOR FRAMES

WINDOW TYPES

F N 100x625 1 2

INSULATED GLAZING UNIT, SEE

GLAZING SPEC. 08 81 00.

FIRE GLASS @ FIRE

RATED ASSEMBLY, SEE

GLAZING SPEC. 08 81 00

A

MANUF. CAM

HARDWARE

LOCK

US Army Corps of Engineers

SHEET ID

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

PR

O

JE

C

T N

U M

BE

R

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D

ES

C R

IP

TI

O N

A-604

U N

AC

C

O M

PA

N

IE

D

E N

L I

ST

ED

P

ER

SO

N N

EL

H

O U

SI

N

G M

O B I

LE

D

IS

T R

IC

T

T.

D

.W

T.

D

.W

C .A

J.

M

.C

FE

BR

U

AU

R Y

W

9R

M

7E U

M

7E C

AMENDMENT 0002

SO

TO

C

AN

O A

IR

B

AS

E, H O

N D

U R

AS

M O

BI

LE

, A

LA

BA

M

A

SE

C

O N

D F

LO

O

R D

O O

R S

C H

ED

U

LE

USACE_DOOR SCHEDULE SECOND FLOOR

DOOR NO. TYPE

DOOR

Finish

FIRE

RATING HARDWARE

FRAME

COMMENTS:

SIZE

MATERIAL TYPE MATERIAL

DETAILS

WIDTH HEIGHT THICKNESS HEAD JAMB SILL

201 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

202 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

203 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

204 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

205A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

205B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

206 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

207 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

208 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

209 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

210 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

211A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

211B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

212 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

213 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

214 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

215 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

216 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

217A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

217B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

218 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

219 F 900 2,100 50 HM PAINTED 1/2HR HW-3 1 HM 3/A607 4/A607 9/A607

220 F 800 2,100 50 WD PAINTED 1/2HR HW-4 1 HM 3/A607 4/A607 9/A607

221 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM 3/A607 4/A607 9/A607

222 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

223 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

224 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

225 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

226A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

226B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

227 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

228 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

229 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

230 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

231 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

232A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

232B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

233 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

234 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

235 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

236 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

237 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 1/A607 4/A607 9/A607

238A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

238B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

239 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

240A N 900 2,100 50 HM PAINTED 1/2 HR HW-4 1 HM 1/A607 2/A607 7/A607

240B N 900 2,100 50 HM PAINTED 1/2 HR HW-4 1 HM 1/A607 2/A607 7/A607

241 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

242A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

242B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

243 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

244 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

245 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

246 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

247 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

248A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

248B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

249 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

250 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

251 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

252 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

253 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

254 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

255 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

256 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

257 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

258A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

258B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

259 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM 3/A607 4/A607 9/A607

260 F 800 2,100 50 WD PAINTED 1/2HR HW-3 1 HM 3/A607 4/A607 9/A607

261 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM 3/A607 4/A607 9/A607

262 B 900 2,100 50 HM PAINTED - HW-9 1 HM 3/A607 4/A607 9/A607

263 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

264 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

265 F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607

266 F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607

267 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

268A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

268B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

269 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

270 F 900 2,100 50 WD PAINTED 1/2HR HW-6 HM 3/A607 4/A607 9/A607

271 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

272 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

273 F 900 2,100 50 WD PAINTED 1/2HR HW-6 HM 3/A607 4/A607 9/A607

274A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

274B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

275 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

276 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

277 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

278 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

279 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

280A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

280B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

M

AR

K D

AT

E

AM

EN

D

M

EN

T

/2

8/

G R

ID

W

IN

D

O W

T

YP

E

AN

D D

O O

R C

O M

M

EN

S

C H

ED

U

LE

D

AS

SCHED

AS

S

C H

ED

U

LE

D

AS

SCHED

M

FR

ST

D

MFR

STD

AS

S

C H

ED

U

LE

D

AS

SCHED 10

AS

S

C H

ED

U

LE

D

AS

SCHED 50

DOOR TYPES DOOR FRAMES

WINDOW TYPES

F N 100x625 1 2

INSULATED GLAZING UNIT, SEE

GLAZING SPEC. 08 81 00.

FIRE GLASS @ FIRE

RATED ASSEMBLY, SEE

GLAZING SPEC. 08 81 00

A

MANUF. CAM

HARDWARE

LOCK

US Army Corps of Engineers

SHEET ID

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

PR

O

JE

C

T N

U M

BE

R

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D

ES

C R

IP

TI

O N

A-605

U N

AC

C

O M

PA

N

IE

D

E N

L I

ST

ED

P

ER

SO

N N

EL

H

O U

SI

N

G M

O B I

LE

D

IS

T R

IC

T

T.

D

.W

T.

D

.W

C .A

J.

M

.C

FE

BR

U

AU

R Y

W

9R

M

7E U

M

7E C

AMENDMENT 0002

SO

TO

C

AN

O A

IR

B

AS

E, H O

N D

U R

AS

M O

BI

LE

, A

LA

BA

M

A

TH

IR

D F

LO

O

R D

O O

R S

C H

ED

U

L E

USACE_DOOR SCHEDULE THIRD FLOOR

DOOR NO. TYPE

DOOR

Finish

FIRE

RATING HARDWARE

FRAME

COMMENTS:

SIZE

MATERIAL TYPE MATERIAL

DETAILS

WIDTH HEIGHT THICKNESS HEAD JAMB SILL

301 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

302 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

303 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

304A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

304B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

305 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

306 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

307 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

308 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

309 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

310 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

311A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

311B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

312 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

313 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

314 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

315 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

316A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

316B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

317 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

318 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

319 F 900 2,100 50 HM PAINTED 1/2HR HW-3 1 HM 3/A607 4/A607 9/A607

320 F 800 2,100 50 WD PAINTED 1/2HR HW-4 1 HM 3/A607 4/A607 9/A607

321 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM 3/A607 4/A607 9/A607

322 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

323 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

324 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

325 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

326A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

326B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

327 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

328 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

329 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

330 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

331 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

332A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

332B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

333 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

334 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

335 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

336 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

337 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

338A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

338B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

339 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

340A N 900 2,100 50 HM PAINTED 1/2 HR HW-2 1 HM 1/A607 2/A607 7/A607

340B N 900 2,100 50 HM PAINTED 1/2 HR HW-2 1 HM 1/A607 2/A607 7/A607

341 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

342A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

342B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

343 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

344 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

345 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

346 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

347 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

348 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

349A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

349B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

350 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

351 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

352 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

353 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

354 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

355 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

356 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

357 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

358A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

358B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

359 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM 3/A607 4/A607 9/A607

360 F 800 2,100 50 WD PAINTED 1/2HR HW-3 1 HM 3/A607 4/A607 9/A607

361 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM 3/A607 4/A607 9/A607

362 B 900 2,100 50 HM PAINTED - HW-9 1 HM 3/A607 4/A607 9/A607

363 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

364 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607

365 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

366 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

367 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

368A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

368B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

369 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

370 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

371 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

372 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

373 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

374A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

374B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

375 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.

376 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

377 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

378 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607

379 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607

380A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

380B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT

M

AR

K D

AT

E

AM

EN

D

M

EN

T

/2

8/

G

R

ID

W

IN

D O

W T

YP

E

AN

D

D O

O R

C O

M M

EN

1/2"

9"

9"

3/ 4"

3/ 4"

6" 3/

4"

1/ 2"

3/ 4"

SIGN TYPE - A

MECHANICAL

ROOM

9"

SIGN TYPE - E

EXIT

1" 1"

1"

3"

Accounting and Finance Officer Military Pay Civilian Pay Travel Pay Commercial Services Document Section

Administration Communications Branch

Central Base Administration Base Locator Documentation Branch Administration Orders Branch Publications Branch Master Reference Library

Civilian Personnel Office Staffing Section Employee Regulations Sections

Classification Section Labor Relation Section Data Management Support

Commander Deputy Commander Executive Officer Senior Enlisted Advisor Administration Conference Room

Director of Personnel Chief of Military Personnel Customer Services Air Force Aid Society Chief Civilian Personnel Placements and Applications Staffing Section Employee Regulations Sections304

116 137

3/4"

3/4"

3/ 4"

3/4" 3' - 10 1/2" 3/4" 4' - 0"

3'

0"

2'

1/

4" 9"

3/ 4"

Building Title

SIGN TYPE - F

3/ 4"

10"

7"

SIGN TYPE - G

"RESTRICTED AREA"

THIS ACTIVITY HAS BEEN DECLARED A RESTRICTED AREA

BY AUTHORITY OF THE INSTALLATION COMMANDER IN

ACCORDANCE WITH THE PROVISIONS OF THE DIRECTIVE

ISSUED BY THE SECRETARY OF DEFENSE ON 10

THE COMMANDER.

DEADLY FORCE IS AUTHORIZED.

DECEMBER 2005, PURSUANT TO THE PROVISIONS OF

SECTION 21, INTERNAL SECURITY ACT OF 1950.

UNAUTHORIZED ENTRY IS PROHIBITED.

ALL PERSONS AND VEHICLES ENTERING HEREIN ARE

LIABLE TO SEARCH. PHOTOGRAPHY OF THE FACILITIES IS

PROHIBITED WITHOUT SPECIFIC AUTHORIZATION FROM

NOTE: BACKGROUND SHALL MATCH GENERAL WALL

PAINT IN COLOR, TITLE SHALL BE MANUFACTURER'S

STANDARD RED, ALL OTHER TEXT SHALL BE BLACK.

1/2" HIGH TEXT

3/8" HIGH TEXT

10"

7"

SIGN TYPE - H

THIS FACILITY IS

PROTECTED BY AN

ALARM SYSTEM

Unauthorized entry is prohibited. Violators will be prosecuted under the provisions of the UCMJ or other applicable laws.

9 1/2"

1/

4"

1/ 4"

YELLOW BACKGROUND

1/2" HIGH BLACK TEXT

1" HIGH YELLOW TEXT

BLACK BACKGROUND

3/8" HIGH BLACK TEXT

9"

/2

SIGN TYPE - J

STAIR

EXIT

1" 1"

1/ 2"

1" 1"

6"

10"

7"

SIGN TYPE - M

WITHIN

50 FEET OF

BUILDING

NO SMOKING

NOTE: SIGN SHALL BE POSTED PER

AR 600-63.

1/

4"

1/ 2"

1"

1/ 4"

1' - 0"

8"

SIGN TYPE - N

IN CASE OF

EMERGENCY CALL

DPW WORK CENTER

AT (719) 526-5345

US Army Corps of Engineers ®

SHEET ID

U.

S.

A

RM

Y

CO

RP

S

O F

EN

G

IN

EE

RS

DR

A W

N

BY

DE

S I

G

NE

D

BY

SU

B M

IT

TE

D

BY

SI

ZE

CH

E C

KE

D

B Y

AN

S I

D

FI

LE

N

AM

E:

IS

SU

E

DA

TE

CO

N T

RA

CT

N O

SO

L I

CI

TA

TI

O

N

NO

PR

O

JE

CT

N

UM

BE

R :

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

DE

SC

RI

PT

IO

N

I-400

UN

AC

C O M

PA

N I

ED

E

NL

IS

TE

D

P E

RS

O N N

EL

H

O

US

IN

G

M O

BI

LE

D

IS

T R

IC

T T.

D.

W

T.

D.

W

C.

A.

J.

M

.C

FE

BR

UA

RY

W

9R

M

7E U4

M

7E U4

AMENDMENT 0002

SO

TO

C

AN

O A

IR

B

AS

E, H O

ND

UR

AS

SA

IN

T

JO

SE

P H

S

TR

EE

T

M O

B I

LE

A L

3 6

T Y

PI

CA

L

SI

G

NA

G

E

1. OVERALL SIGN SIZE VARIES DEPENDENT ON NUMBER OF LINES OF TEXT.

2 SEE SPEC SECTIONS 10-14-02 FOR SIGNAGE SCHEDULE.

GENERAL NOTES:

R

EV

IS

ED

N O

TE

M

AR

K

DA

TE

AM

EN

D

M

EN

T

/2

8/

1. THE ENTIRE BUILDINGS SHALL BE FULLY PROTECTED BY AUTOMATIC FIRE SUPPRESSION SYSTEMS INSTALLED IN ACCORDANCE WITH NFPA 13R, NFPA 13, UFC-3-600-01, AND BASE SPECIFIC CRITERIA. THE SYSTEM TYPES SHALL BE WET, DRY, AGENT AS INDICATED, UNLESS REQUIRED OTHERWISE BY CODE OR BASE CRITERIA.

2. THE FIRE SUPPRESSION SYSTEMS SHALL BE DESIGNED, INSTALLED AND TESTED IN ACCORDANCE WITH THE

FOLLOWING CRITERIA:

A. UFC-3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES.

B. NFPA-13R STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS.

3. THE SPRINKLER SYSTEMS SHALL BE HYDRAULICALLY CALCULATED IN ACCORDANCE WITH NFPA-13. DESIGN DENSITIES AND HOSE STREAM ALLOWANCE SHALL BE AS IDENTIFIED IN THE TABLE ON THIS SHEET:

4. MAXIMUM AREA OF COVERAGE PER SPRINKLER SHALL BE IN ACCORDANCE WITH UFC-3-600-01 FOR THE APPLICABLE

HAZARD AND TYPE OF SPRINKLER, OR IN ACCORDANCE WITH MANUFACTURER'S LISTINGS.

5. QUICK RESPONSE SPRINKLERS SHALL BE USED THROUGHOUT, EXCEPT IN ROOMS OR AREAS FOR WHICH QUICK RESPONSE SPRINKLERS ARE NOT LISTED, OR WHERE THEIR USE HAS BEEN SPECIFICALLY PROHIBITED BY THE

UFC

6. ALL FIRE PROTECTION SYSTEM CONTROL VALVES SHALL BE PROVIDED WITH SUPERVISORY SWITCHES BY THE SPRINKLER CONTRACTOR. ALL ELECTRICAL DEVICES FOR THE FIRE PROTECTION SYSTEM SHALL BE COMPATABLE

WITH THE FIRE ALARM SYSTEM.

7. PIPING SHALL BE INSTALLED SO THAT ALL PORTIONS OF THE SYSTEM CAN BE DRAINED BACK THROUGH VALVES IN

ACCORDANCE WITH THE REFERENCED NFPA STANDARDS.

8. ALL FIRE WALL PENETRATIONS SHALL BE MADE WITH UL APPROVED FIRESTOPPING SYSTEMS LISTED TO MAINTAIN

THE FIRE RATING OF THE WALLS IN WHICH THEY ARE INSTALLED.

9. INSPECTOR'S TEST VALVE TO BE PIPED FROM END OF LAST BRANCH LINE WITH NO EXPOSED PIPE IN FINISHED

SPACES.

10. FULLY COORDINATE INSTALLATION OF PIPE WITH ALL OTHER TRADES, WITH PARTICULAR EMPHASIS ON COORDINATION WITH HVAC DUCTWORK. SPRINKLER PIPE SHALL NOT BE SUSPENDED FROM DUCT HANGERS UNLESS THESE SUPPORTS ARE SPECIFICALLY DESIGNED TO ACCOMMODATE SPRINKLER PIPE. HANGERS SHALL BE IN ACCORDANCE WITH NFPA 13. NO OTHER SYSTEM SHALL BE SUPPORTED FROM SPRINLER PIPING.

11. FIRE DEPARTMENT CONNECTION FOR THE SPRINKLER SYSTEM SHALL BE PROVIDED WITH NAME PLATES PERMANENTLY ATTACHED TO IDENTIFY THE SYSTEM TYPE AND BUILDING SERVED, IN ACCORDANCE WITH APPLICABLE

REQUIREMENTS OF NFPA 13.

12. ALL SPRINKLER PIPING SHALL BE SCHEDULE 40 BLACK STEEL.

FIRE SUPPRESSION NOTES

13. FIRE FLOW TEST DATA:

STATIC PRESSURE: 303 kPa RESIDUAL PRESSURE: 207 kPa FLOW: 102 lps

DATE: 14 MAR 2018

(44 PSI)

(30 PSI)

(1619 GPM)

PERFORM A CONFIRMING FLOW TEST IN ACCORDANCE WITH NFPA 291 AND

USE DATA OBATINED FOR FINAL DESIGN.

PRESSURE GAUGES INDICATOR

THRUST BLOCK

FROM

FIRE PUMP

HOUSE

914 MM

INSULATING FLANGE

M M

DRAIN LINE

FIRE DEPT.

CONNECTION

MM

(TYP.)

UL

MIN

STEEL PIPING

(TYP)

GATE VALVE

ALARM

CHECK

VALVE

CHECK

VALVE

WATERFLOW

SPRINKLER SYSTEM

TO WET-PIPE

FIRE SUPPRESSION HAZARD SCHEDULE

ALLOWANCE

MECH RM, 232.3 SQ M WET PIPE

AREA

AREA OF

OPERATIONRATING

HAZARD

DENSITY SYSTEM

TYPE OF

SYMBOLSTREAM

HOSE

DORMS 4 SPRINKLESRESIDENTIAL 2.0 LPM/SQ M WET PIPE 15.8 LPS

OHJANITORS CLOSET

RH

15.8 LPS

ORDINARY

HAZARD 8.0 LPM/SQ M

AREAS

ALL OTHER 139.4 SQ M

HAZARD

LIGHT 4.0 LPM/SQ M WET PIPE 15.8 LPS LH

TO SPRINKLER

SYSTEM

BALL VALVE (TYP)

SIGHT GLASS

ORIFICE SIZED FOR FLOW OF

SMALLEST SPRINKLER HEAD ON

FLOOR.

6" COMBINATION SPRINKLER/

STANDPIPE RISER

2" DRAIN RISER

INSPECTOR'S TEST AND

DRAIN CONNECTION

US Army Corps of Engineers ®

SHEET ID

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

PR

O

JE

C

T N

U M

BE

R

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D

ES

C R

IP

TI

O N

M O

BI

LE

, A L

FX001

UN

AC

C O M

PA

N I

ED

E

NL

IS

TE

D

P E

RS

O N N

EL

H

O

US

IN

G

M O

B I

LE

D

IS

T R

IC

T R

.P

ER

SO

N

EN

-D

E

W .K

N

AP

P

B.

D

U R

H

AM

FE

BR

U

AR

Y

W

9R

M

7E U

M

7E U

SO

TO

C

AN

O A

IR

B

AS

E, H O

ND

UR

AS

F I

RE

S U P

PR

E S

SI

O

N

M

AR

K D

AT

E

AM

M

EN

D .0

/2 9/

N.T.S.

1 WET PIPE RISER N.T.S.

2 SPRINKLER FLOOR ZONE VALVE DETAIL

AD

D

ED

F

LO

O

R Z

O N

E

VA

LV

E

D

ET

AI

L

AMENDMENT 0002

P

SP SP

SP

SP SP

SP SP

SP SP

SP SPSP

LOC

P P P PTE

XT

KEY PLAN

A B

CORR

MECH

LAUNDRY

ELEC

DORM

CLOSET

CLOSET

MECH

DORM

DORM

CLOSET

CLOSET

MECH

DORM

DORM

CLOSET

CLOSET

MECH

DORM

DORM

CLOSET

CLOSET

MECH

DORM

DORM

CLOSET

CLOSET

MECH

DORM

CLOSET

CLOSET

MECH

BATHROOM

BATHROOM

BATHROOM

BATHROOM

BATHROOM

BATHROOM

DORM

DORM

WP

US Army Corps of Engineers

SHEET ID

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

PR

O

JE

C

T N

U M

BE

R

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D

ES

C R

IP

TI

O N

FA103

U N

AC

C

O M

PA

N

IE

D

E N

L I

ST

ED

P

ER

SO

N N

EL

H

O U

SI

N

G M

O B I

LE

D

IS

T R

IC

T

R .M

.F O

R

TN

ER

EN

-D

E

W .J

. K N

AP

P

D .D

. C O

LL

IE

R

FE

B R

U

AR

Y

W

9R

M

7E U

M

7E U

SO

TO

C

AN

O A

IR

B

AS

E, H O

N D

U R

AS

M O

BI

LE

, A

LA

BA

M

A

S E C

O N

D F

L O O

R F

IR

E

A L

AR

M

M A S

S N

O

TI

FI

C

AT

IO

N

PL

AN

AR

E A

"A

PLAN NORTH

SCALE:

0 40002000

1 : 50

1 : 501 SECOND FLOOR FIRE ALARM & MASS NOTIFICATION PLAN - AREA "A"

M

AR

K D

AT

E

AM

E N D

.0

3 /

/2

AD

D

ED

T

AM

PE

R A

N D

F

LO

W S

W

IT

C H

ES

P

SP SP

SP

SP SP

SP SP

SP SP

SP SPSP

LOC

P P P P

TE

XT

KEY PLAN

A B

CORR

MECH

LAUNDRY

ELEC

DORM

CLOSET

CLOSET

MECH

CLOSET

CLOSET

MECH

DORM

CLOSET

CLOSET

MECH

DORM

CLOSET

CLOSET

MECH

DORM

CLOSET

CLOSET

MECH

DORM

CLOSET

CLOSET

MECH

BATHROOM

BATHROOM

BATHROOM

BATHROOM

BATHROOM

BATHROOM

DORM

DORM

DORM

DORM

DORM

DORM

373DORM

WP

US Army Corps of Engineers

SHEET ID

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

PR

O

JE

C

T N

U M

BE

R

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D

ES

C R

IP

TI

O N

FA105

U N

AC

C

O M

PA

N

IE

D

E N

L I

ST

ED

P

ER

SO

N N

EL

H

O U

SI

N

G M

O B I

LE

D

IS

T R

IC

T

R .M

.F O

R

TN

ER

EN

-D

E

W .J

. K N

AP

P

D .D

. C O

LL

IE

R

FE

B R

U

AR

Y

W

9R

M

7E U

M

7E U

SO

TO

C

AN

O A

IR

B

AS

E, H O

N D

U R

AS

M O

BI

LE

, A

LA

BA

M

A

TH

IR

D F

LO

O

R F

I R E

AL

AR

M

M

AS

S N

O T I

FI

C

A T

IO

N

PL

AN

AR

E A

"A

PLAN NORTH

SCALE:

0 40002000

1 : 50

1 : 501 THIRD FLOOR FIRE ALARM & MASS NOTIFICATION PLAN - AREA "A"

M

AR

K D

AT

E

AM

E N D

.0

3 /

/2

AD

D

ED

T

AM

PE

R A

N D

F

LO

W S

W

IT

C H

ES

ALL FLOOR DRAINS SHALL HAVE TRAP PRIMER CONNECTIONS AND SHALL BE SUPPLIED FROM

AUTOMATIC TRAP PRIMERS CONNECT TO THE NEAREST SINK. RUN 1/4" SOFT COPPER TUBING

FROM TRAP PRIMERS TO FLOOR DRAIN TRAP PRIMER CONNECTION. TRAP PRIMERS SHALL BE

EQUAL TO ZURN "SANI-GUARD" MODEL Z-1022.

CONTRACTOR SHALL FURNISH AND INSTALL WATER SHOCK ARRESTERS EQUAL TO ZURN

SHOKTROL AS SHOWN ON PLANS AND AS PER MANUFACTURER'S RECOMMENDATIONS. AIR

CHAMERS SHALL NOT BE SUBSTITUTED FOR FACTORY FABRICATED WATER SHOCK ARRESTORS.

ALL PIPING SHALL BE FIRMLY ANCHORED AND SUPPORTED TO PREVENT SWAY AND VIBRATION THE ENTIRE

LENGTH.

ALL COPPER WATER LINE PENETRATIONS THROUGH WALLS SHALL BE SLEEVED.

UNLESS INDICATED OTHERWISE, ALL BELOW SLAB COLD WATER AND HOT WATER PIPING SHALL BE TYPE "K"

COPPER.

UNLESS INDICATED OTHERWISE, ALL ABOVE SLAB COLD WATER AND HOT WATER PIPING SHALL BE TYPE "L" COPPER TUBING IN ACCORDANCE WITH ASTM B 88. PIPE FIITINGS SHALL BE COPPER OR COPPER ALLOY IN

ACCORDANCE WITH ASME 16.22.. JOINTS SHALL BE SOLDER ACCORDANCE WITH ASTM B 828

USING "LEAD FREE" SOLDER IN COMPLIANCE WITH ASTM B 32.

INSULATE ALL EXPOSED PIPES AND SURFACES UNDER ACCESSIBLE LAVATORIES AND COUNTER

SINKS PER ADA 4.19.4 AND ANSI-A117.1. PROVIDE ONE PIECE PROTECTOR WITH FULL ROTATION OPTION CONSISTING OF INTERNAL GROOVE LOCKING RING FOR NON SEPERATION AND EXTERNAL LOCKING RING WITH STAINLESS STEEL SECURITY SCREW TO INSURE EXTRA LONG TERM TAMPER RESISTANCE ANTIMICROBIAL U.V. INHIBITED UNIVERSAL FIT, 3-M DUAL LOCK (TM) FASTENERS

SECURED WITH SELF LOCKING APPROVED NYLON STRAPS. FURNISH ONE PIECE VALVE/ANGLE

STEP PROTECTOR. ONE PIECE OFFSET PROTECTOR AND ONE PIECE P-TRAP PROTECTOR.

PRO-XTREME BY PLUMBEREX.

SET WATER HEATER THERMOSTAT TO PREVENT PROMOTION OF LEGIONELLA. FURNISH

TEMPERING MIXING VALVE TO PROVIDE 43.3°C WATER AT THE PLUMBING FIXTURES.

AND SMALLER AND 1 MM PER M (1%) FOR PIPES 75 MM AND LARGER.

PROVIDE 305 x305 ACCESS DOORS ON ALL NON-ACCESSIBLE CEILINGS AND WALLS

PIPE ALL P&T VALVES FROM WATER HEATERS TO OUTSIDE OF BUILDING USING

SEAL ALL PENETRATIONS OF FIRE RATED PARTITIONS WITH FIRE RATED STOPPING MATERIAL.

PROVIDE DIELECTRIC UNIONS AT ALL CONNECTIONS OF DISSIMILAR METALS.

ALL SOIL, WASTE, AND VENT PIPING SHALL BE SLOPED 21 MM PER M (2%) FOR PIPES 2 1/2"

INSULATE ALL HOT WATER PIPING, TEMPERED WATER PIPING AND HOT WATER RECIRCULATING PIPING WITH 1 1/2"

ESCUTCHEON PLATES AT THE WALL, FLOOR OR CEILING PENETRATIONS.

ALL EXPOSED PIPING AT PLUMBING FIXTURES SHALL BE CHROME PLATED BRASS WITH

ALL PIPING SHALL BE CONCEALED WITHIN THE CEILING SPACE, WALLS AND CHASES AS SHOWN

REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ALL

INSTALL ALL WATER, WASTE AND VENT PIPING IN ACCORDANCE WITH ALL APPLICABLE CODES.

COORDINATE WORK WITH ALL OTHER TRADES TO AVOID INTERFERENCES.

PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL VERIFY ALL EXISTING BUILDING

ALL SHUT-OFF VALVES SHALL BE BALL VALVES.

FURNISH SUPPLIES WITH STOP VALVES FOR ALL PLUMBING FIXTURES.

13.

11.

28.

FOR VALVES

FULL SIZE COPPER PIPING.

29.

16.

26.

25.

24.

23.

22.

21.

20.

19.

18.

17.

15.

14.

12.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

PLUMBING GENERAL NOTES

ALL WATER PIPING SHALL BE SLOPED TO DRAIN.

ON PLANS.

PLUMBING FIXTURES.

CONDITIONS.

ALL WORK SHALL CONFORM WITH UFC 3-420-01 AND ALL OTHER APPLICABLE CODES AND

STANDARDS.

ALL HANDICAP FIXTURES SHALL BE MOUNTED IN ACCORDANCE WITH THE AMERICANS WITH

DISABILITIES ACT (ADA) AND ALL OTHER PERTINENT ACCESSIBILITY CODE FOR BUILDING

CONSTRUCTION.

PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL VERIFY EXACT LOCATIONS OF UTILITIES IN FIELD.

SOIL, WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC IN ACCORDANCE WITH ASTM D 2665.

PVC PIPE FITTINGS SHALL BE IN ACCORDANCE WITH ASTM D 3311. JOINTS SHALL BE SOLVENT

CEMENTED IN ACCORDANCE WITH ASTM D 2855 USING SOLVENT CEMENT IN COMPLIANCE WITH

ASTM D 2564.

30. ALL FLOOR CLEAN OUT PLUGS SHALL BE PVC.

FIBERGLASS INSULATION PER SPECIFICATIONS.

FURNISH RELAYS NECESSARY FOR THE DDC CONTROL SYSTEM TO CONTROL THE WATER

HEATER AND THE HOT WATER RECALCULATION PUMP.

***31. THE ENTIRE SOLAR WATER HEATING SYSTEM IS BID OPTION #1. THIS INCLUDES, BUT NOT LIMIT TO, SOLAR COLLECTORS, SOLAR PUMPS SP-1 &SP-2, SOLAR STORAGE TANK, AND DRAIN BACK TANK.

PLUMBING FIXTURE SCHEDULE

SUPPLY SIZE (mm)

MM

WASTE

HOT COLD

FIXTURESNO. DESCRIPTION

COORDINATE PLUMBING PIPING WITH HVAC DUCTS AND ELECTRICAL CONDUIT.

GENERAL NOTES

SEE ARCHITECTURAL PLANS FOR LOCATION OF ALL PLUMBING FIXTURES1 - ALL VENTS THRU ROOF (VTR) SHALL BE OFFSET A MINIMUM OF 4.6m

ALL WATER PIPING SHALL BE RUN ABOVE CEILING UNLESS OTHERWISE NOTED.2

FROM ALL OUTSIDE INTAKES.

-3

HC - HANDICAPPED

MM

VENT

PROVIDE INSULATING COVER FOR ALL EXPOSED DRAIN AND WATER4 -

PIPING FOR H.C. ACCESSIBLE LAVATORIES.

PRESSURE BALANCED SINGLE LEVER MIXING VALVE WITH STOPS,

100 15--P1

75 15 15P3

FLOOR DRAINFD-1 75 -- -- FLOOR DRAIN W/ SQUARE TOP AND TRAP PRIMER CONNECTION.

LAUNDRY BOXP5 50 15 15 20 GAUGE HOT DIPPED GALVANIZED STEEL LAUNDRY BOX WITH VALVES, DRAIN, AND ARRESTORS. FIRE RATED CONSTRUCTION.

WATER CLOSET

SHOWER

P2

ELONGATED SEAT, CLOSED FRONT W/ COVER, STAINLESS STEEL POSTS. ANGLE STOPS. CLOSET RISER.

VITREOUS CHINA FLOOR MOUNTED, SIPHON JET, TANK TYPE, BOTTOM OUTLET, WHITE VITREOUS CHINA, ELONGATED BOWL. (4.8 L PER FLUSH)

COUNTERTOP LAVATORY 1532 50 15 40mm, 17GA. P-TRAP. SUPPLIES W/ ANGLE STOPS.

A.D.A. COMPLIANT FAUCET, SINGLE CONTROL, POP UP DRAIN AND LIFT ROD IN BRUSHED SATIN FINISH, AND 1.9L/min (0.5 GPM) RESTRICTOR.

500mmX450mm, VITREOUS CHINA COUNTERTOP, 100mm CENTERS, SELF RIMMING, FRONT OVERFLOW.

WALL HYDRANTP4 - - 15

PERMANENT STAINLESS STEEL SEAT, ADJUSTABLE TEFLON IMPREGNATED PACKING NUT, STANDARD O SEAT WASHER, SINGLE KEY OPERATION,

- VACUUM BREAKER CAP & BODY.

SERVICE SINKP7 75 15 15 SEE SPECIFICATIONS.50

DRINKING FOUNTAIN

WH

HUB DRAIN

FLOOR DRAIN (FD)

INCREASER

HOSE BIBB (HB)

SILL COCK (SC)

CHECK VALVE

BALANCE VALVE UNLESS NOTED OTHERWISE

NOT TO SCALE

ABOVE CEILING

CLEANOUT (C.O.)

UNION

NTS

AC

UNO

E.C.O.

D.F.

F.C.O.

EXTERIOR CLEANOUT

FLOOR CLEANOUT

WATER HAMMER

SANITARY SEWER

HOT WATER

COLD WATER

SS

(44°C)

PLUMBING LEGEND

GLOBE VALVE

GATE VALVE

TRAP PRIMER

VENT

SOIL , WASTE

T

FD

DN

WHA " "

H.B.

V.T.R.

FLOOR DRAIN

DOWN

VENT THRU ROOF

HOSE BIBB

SCREWED & FLANGED

CHECK VALVE

GATE VALVE

PIPE TEST PLUG

FLEX. PIPE CONN.

CONCENTRIC REDUCER

HP HOT WATER REC. PUMP

RD ROOF DRAIN

ARRESTOR "SIZE"

EWH ELECTRIC WATER HEATER

B.F. BELOW FLOOR

HOT WATER RETURN

TP TRAP PRIMER

HOT WATERHW (60°C)60°C

WALL HYDRANT

FM FIRE MAIN

MANUAL AIR VENT

PUMP

CALIBRATED BALANCING

VALVE

FF FINISHED FLOOR

AFF ABOVIE FINISHED FLOOR

IWFT

INDIRECT FUNNEL AND

WASTE TRAP

W.C.O. WALL CLEANOUT

BOP BOTTON OF PIPE

C CENTER LINE

TOP TOP OF PIPE

L

US Army Corps of Engineers ®

SHEET ID

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

K E

D B

Y:

AN

SI

D

FI

LE

N

A M E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

PR

O

JE

C

T N

U M

BE

R

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D

ES

C R

IP

TI

O N

M O

BI

LE

, A L

P001

UN

AC

CO

M

PA

NI

ED

E

NL

IS

TE

D

PE

R S

O

NN

EL

H

O

US

IN

G

M O

BI

LE

D

IS

TR

IC

T R

. P

ER

SO

N

EN

-D

E

W . K

N

AP

P

B.

D

U R

H

AM

FE

BR

U

AR

Y

W

9R

M

7E U

M

7E U

SO

TO

C A N

O A

IR

B

AS

E, H O

ND

UR

AS

PL

UM

BI

NG

N O

TE

S, L

EG

EN

D , A

ND

S

CH

E D

UL

E

M

AR

K D

AT

E

AM

EN

D

.0

/2

9/

R

EV

IS

ED

S C

H

ED

U

LE

A N

D N

O

TE

S.

W

W W

W W

W W

W W

W W

W W

W W

1 2 3 4 5 6 7 8 9

A

B

C

D

1 2 3 4 5 6 7 8 9

B

C

D

PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1

PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1

EF-1 EF-1 EF-1

EF-1

(TYP.) EF-1 EF-1

EF-1EF-1EF-1

EF-1

EF-1EF-1

PTAC-1

AHU-1

DORM

157ELEC

LAUNDRY

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

200 MM WALL CAP

W/ B.D.D. (TYP.)

FC-1

FC-2

CU-1 CU-2 CU-3

CU-4 CU-5 CU-6 CU-8 CU-9

EF-2

EF-3

200x100 24 L/s

76ø 76ø 76ø

76ø76ø 76ø

76ø

76ø

76ø

76ø

76ø

76ø

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s 200x100

24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

203x102

200x100 24 L/s

203x102

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

457x457

DRYER EXH.

DUCT(4-TYP)

PTAC CONDENSATE DRAIN

DN TO DRYWELL (TYP.)

203x305 305x305

305x305

305x305 305x305 203x305 203x305

CU-7

254ø 254 EA UP TO

2ND FLR EA LVR

PLENUM

102ø

102 EA UP TO

2ND FLR

355x355 236 L/s

1 2 3 4 5 6 7 8 9

A

B

C

D

1 2 3 4 5 6 7 8 9

A

B

C

D

PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1

PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1

EF-1

EF-1 EF-1 EF-1 EF-1 EF-1

EF-1EF-1EF-1EF-1EF-1EF-1

PTAC-1

AHU-2

200 MM WALL CAP

W/ B.D.D. (TYP.)

FC-1

FC-2

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

LAUNDRY

ELEC

MECH

219 ACTIVITY

DAYROOM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

EF-2

EF-3

457x457

DRYER EXH.

DUCT(4-TYP)

PTAC CONDENSATE DRAIN

DN TO DRYWELL (TYP.)

203x305 203x305

305x305

305x305 305x305 305x305 203x305 203x305

76ø

76ø76ø76ø

76ø 76ø

76ø

76ø

76ø 76ø

76ø 76ø

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s200x100

24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

NONVENTED LOUVER

SEE ARCHITECTURE

FOR DETAILS

610x914 E.A.

LOUVER

W/ B.S.

254ø

254ø

127ø

102ø

355x355 236 L/s

GENERAL SHEET NOTES:

SEE SHEET M-001 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.1.

PLAN NORTH IS FOR REFERENCE ONLY AND IS BASED ON BUILDING D. SEE CIVIL

FOR BUILDING ORIENTATION.

2. US Army Corps of Engineers ®

SHEET ID

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

K E

D B

Y:

AN

SI

D

FI

LE

N

A M E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

PR

O

JE

C

T N

U M

BE

R

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D

ES

C R

IP

TI

O N

M O

BI

LE

, A L

M101

UN

AC

CO

M

PA

NI

ED

E

NL

IS

TE

D

PE

R S

O

NN

EL

H

O

US

IN

G

M O

BI

LE

D

IS

TR

IC

T R

. P

ER

SO

N

R . P

ER

SO

N

W . K

N

AP

P

B.

D

U R

H

AM

FE

BR

U

AR

Y

W

9R

M

7E U

M

7E U

SO

TO

C A N

O A

IR

B

AS

E, H O

ND

UR

AS

HV

A C

F

LO

O R

P L

AN

1 : 1001 HVAC PLAN 1ST FLOOR

1 : 1002 HVAC PLAN 2ND FLOOR

PLAN NORTH

SCALE:

0 80004000

1 : 100NOTE: ALL UNITS ARE IN MILLIMETERS

UNLESS INDICATED OTHERWISE.

M

AR

K D

AT

E

AM

EN

D

.0

/2

9/

C

LA

R

IF

IE

D

M

EC

H

J

AN

IT

O

R E

XH

, L

AU

N

D S

U

PP

W W

W W

W W

1 2 3 4 5 6 7 8 9

A

B

C

D

1 2 3 4 5 6 7 8 9

A

B

C

D

PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1

PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1

EF-1 EF-1 EF-1 EF-1 EF-1 EF-1

EF-1EF-1EF-1

EF-1

EF-1

EF-1

PTAC-1

1270x1270

O.A. INTAKE

LOUVER W/ B.S.

200 MM WALL CAP

W/ B.D.D. (TYP.)

FC-1

FC-2

AHU-2

DORM

DORM

DORM

DORM

DORM

DORM

MECH

ACTIVITY

DORM

DORM

DAYROOM

LAUNDRY

ELEC

DORM

DORM

376DORM

DORM

DORM

DORM

DORM

DORM

DORM

DORM

348DORM

EF-2

EF-3

DORM

DORM

DORM

DORM

457x457

305x305305x305

457x305 203x305

DORM

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

200x100 24 L/s

76ø 76ø 76ø

76ø76ø76ø

76ø 76ø 76ø

76ø

76ø 76ø102ø

DRYER EXH.

DUCT(4-TYP)

PTAC CONDENSATE DRAIN

DN TO DRYWELL (TYP.)

203x305203x305 305x305 203x305

254ø

254 EA DN TO

2ND FLR EA LVR

PLENUM

102ø

102 EA DN TO

2ND FLR EA LVR

PLENUM

355x355 236 L/s

GENERAL SHEET NOTES:

SEE SHEET M-001 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.1.

PLAN NORTH IS FOR REFERENCE ONLY AND IS BASED ON BUILDING D. SEE CIVIL

FOR BUILDING ORIENTATION.

2.

EF-4

T

US Army Corps of Engineers ®

SHEET ID

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

K E

D B

Y:

AN

SI

D

FI

LE

N

A M E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

PR

O

JE

C

T N

U M

BE

R

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D

ES

C R

IP

TI

O N

M O

BI

LE

, A L

M102

UN

AC

CO

M

PA

NI

ED

E

NL

IS

TE

D

PE

R S

O

NN

EL

H

O

US

IN

G

M O

BI

LE

D

IS

TR

IC

T R

. P

ER

SO

N

EN

-D

E

W . K

N

AP

P

B.

D

U R

H

AM

FE

BR

U

AR

Y

W

9R

M

7E U

M

7E U

SO

TO

C A N

O A

IR

B

AS

E, H O

ND

UR

AS

HV

A C

F

LO

O R

P L

AN

1 : 1001 HVAC PLAN 3RD FLOOR

PLAN NORTH

SCALE:

0 80004000

1 : 100

M

AR

K D

AT

E

AM

EN

D

.0

/2

9/

1 : 1002 HVAC PLAN PUMP BLDG

**NOTE: SEE CIVIL FOR BLDG SITE LOCATION.

C

LA

R

IF

IE

D

M

EC

H

J

AN

IT

O

R E

XH

, L

AU

N

D S

U

PP

A B C DA B C D

457x457

457x457

457x457

457x457

457x457

457x457

457x457

AHU-3

AHU-2

AHU-1

1270x1270

O.A. INTAKE

LOUVER W/ B.S.

305x305 S.A.

ABV CEILING

(TYP)

SOLAR WATER EATING

PANELS (TYPICAL OF BLDG'S

E & F. SEE PLUMBING )

SOLAR WATER HEATING

PANELS (TYPICAL OF

BLDG D)

4- DRYER VENTS

(3-TYPICAL)

102ø

102ø 102ø

102ø

102ø

102ø 102ø

102ø

102ø

102ø 102ø

102ø

305x457

305x457

305x457

GENERAL SHEET NOTES:

SEE SHEET M-001 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.1.

PLAN NORTH IS FOR REFERENCE ONLY AND IS BASED ON BUILDING D. SEE CIVIL

FOR BUILDING ORIENTATION.

2.

A BA B

610x914 E.A.

LOUVER W/ B.S.

&PLENUM BEHIND

254ø

254ø

254ø

305ø

254ø

254ø

127ø

127ø

127ø

102ø

EF-2

EF-2

EF-2

E.A. DUCT FROM

JANITOR EF-3

E.A. DUCT FROM

JANITOR EF-3

E.A. DUCT FROM

JANITOR EF-3

US Army Corps of Engineers ®

SHEET ID

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

K E

D B

Y:

AN

SI

D

FI

LE

N

A M E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

PR

O

JE

C

T N

U M

BE

R

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

D

ES

C R

IP

TI

O N

M O

BI

LE

, A L

M301

UN

AC

CO

M

PA

NI

ED

E

NL

IS

TE

D

PE

R S

O

NN

EL

H

O

US

IN

G

M O

BI

LE

D

IS

TR

IC

T R

. P

ER

SO

N

EN

-D

E

W . K

N

AP

P

B.

D

U R

H

AM

FE

BR

U

AR

Y

W

9R

M

7E U

SO

TO

C A N

O A

IR

B

AS

E, H O

ND

UR

AS

HV

AC

B

UI

LD

IN

G S

E C

TI

O N

M

AR

K D

AT

E

AM

EN

D

.0

/2

9/

1 : 501 MECHANICAL BLDG CROSS SECTION

1 : 502 MECHANICAL AND JANITOR RMS EXHAUST SECTION

C

LA

R

IF

IE

D

M

EC

H R

M

J

AN

IT

O

R E

XH

AU

ST

UNIT CU-1, 2, & 3 SHALL BE PROVIDED WITH LEAD DIGITAL SCROLL COMPRESSOR.

AIR COOLED

CU-2

ELECTRICAL

STEPS OF REDUCTION/COMPRESSOR

LOW AMBIENT TEMP.- °C (°F)

DESIGN AMBIENT EMP.- °C (°F)

NO. OF COMPRESSORS

REMARKS:

DATA

HERTZ

MAX. UNIT KW.

VOLTS

PHASE

CAPACITY KW (MBH)

MARK

TYPE

ASSOCIATED FAN COIL

UNITARY CONDENSING UNIT SCHEDULE

AIR COOLED

CU-3CU-1

AIR COOLED

35(120)

AHU-1

1.

ALL CONDENSING UNITS SHALL BE PROVIDED WITH SATURATED SUNCTION TEMPERATURE OF2.

5.55 DEG C.

UNIT CU-1, 2, & 3 SHALL BE PROVIDED WITH DUAL REFRIGERANT CIRCUITS3.

1.7 (35)

35 (95)

2.6 (9)

AIR COOLED

CU-5

FC-1

CU-4

AIR COOLED

35(120)

AHU-2

35(120)

AHU-3

1.7 (35)

35 (95)

2.6 (9)

FC-2

1.7 (35)

35 (95)

2.6 (9)

AIR COOLED

CU-7

FC-1

CU-6

AIR COOLED

1.7 (35)

35 (95)

2.6 (9)

FC-2

1.7 (35)

35 (95)

2.6 (9)

AIR COOLED

CU-9

FC-1

CU-8

AIR COOLED

1.7 (35)

35 (95)

2.6 (9)

FC-2

DATA

FILTER

DATA

ELECTRICAL

DATA

COIL

COOLING

DATA

FAN

NO. OF ROWS

MAXIMUM FINS/CM

MAX. OUTLET VEL.-M.P.M.

FAN TYPE

MINIMUM OUTSIDE AIR-LPS

LVG. DB/LVG. WB - C

ENT. DB/ENT. WB - C

HERTZ

PHASE

VOLTS

MOTOR KW

MARK

TYPE

LOCATION

MAXIMUM FAN R.P.M.

EXT. S.P.- PA.

CAPACITY (KW

MIN. SAT. SUC. TEMP.-C

MAX. FACE VEL.-M.P.M.

SUPPLY AIR-LPS

TYPE

MAX. FACE VEL.-F.P.M.

INITIAL P.D.- PA

FINAL P.D.- PA

REMARKS:

MAX. AIR P.D.- PA.

AHU-1

DRAW THRU

MECH RM

F.C.

27.2/26.11

12.22/12.22 152.8 5.55

.75

MERV 13

1. PROVIDE WITH VARIABLE FREQUENCY DRIVE AND

PREMIUM EFFICIENCY MOTOR RATED FOR INVERTER DUTY.

2. FAN SHALL BE SELECTED BASED ON DIRTY FILTER

CONDITIONS.

3. PROVIDE WITH STAINLESS STEEL COIL HEADERS.

4. PROVIDE STAINLESS STEEL DRAIN PAN.

AIR HANDLING UNIT SCHEDULE

5. AIR HANDLING UNITS CASING SHALL BE DOUBLE WALLED.

6. AIR HANDLING UNITS SHALL BE PROVIDED WITH DUAL FULL-FACED

REFRIGERANT CIRCUITS.

F.C. = FORWARD CURVED

AHU-2

DRAW THRU

MECH RM

F.C.

27.2/26.11

12.22/12.22 152.8 5.55

.75

MERV 13

AHU-3

DRAW THRU

MECH RM

F.C.

27.2/26.11

12.22/12.22 152.8 5.55

.75

MERV 13

DATA

HEATING

STEPS

KW 7.5

.7.5

7.5

L/S (CFM) (HIGH SPEED)

INPUT WATTS @ ARI COND.

ELECTRICAL

REMARKS:

DATA

COOLING

DATA

60HERTZ

PHASE

VOLTS

TOTAL CAP. KW (MBH)

SENS. CAP. KW (MBH)

DESIGN AMB. TEMP.-°C (°F)

TYPE

MARK

35 (95)

2.5 (8.5)

2.6 (9)

113 (240)

WALL MTD

FC-1

UNITARY FAN COIL UNIT SCHEDULE

35 (95)

2.5 (8.5)

2.6 (9)

113 (240)

WALL MTD

FC-2

OUTSIDE AIR - LPS

DATA

HEATING

DATA

ELECTRICAL

DATA

COOLING

INDOOR FAN - LPS

ENT. DB/ENT. WB - C

NO. OF STEPS

HEATER SIZE - KW

HERTZ

PHASE

VOLTS

KW INPUT

MARK

TYPE

TOTAL CAPACITY (KW)

MIN. UNIT EER

AMBIENT TEMP. - C

NOTES: UNIT HAS TWO-SPEED FAN.

AIR CONDITIONER SCHEDULE

PACKAGED TERMINAL

PTAC-1

THRU WALL

2.64

24/17

N.A.

.5

REFRIGERANT SHALL BE R-410a.

ELECTRICAL

EXTERNAL S.P.- PA.

REMARKS:

DATA PHASE

VOLTS

MOTOR - WATTS

HERTZ

DRIVE TYPE

M…

This is the start of the file's text. The full file is on GovTribe.