US Army Corps of Engineers
MOBILE DISTRICT
109 SAINT JOSEPH STREET
MOBILE AL 36602
MOBILE DISTRICT PROJECT CODE :
SOLICITATION NUMBER :
UNACCOMPANIED ENLISTED
PERSONNEL HOUSING
SOTO CANO AIR BASE, HONDURAS
M017EU44
W9127819R0028
MARCH 2019 AMENDMENT NO. 0002
A B C
C1
D
SCALE: NTS SCALE: NTS SCALE: NTS
SCALE: NTS
WALL TYPE WALL TYPE WALL TYPE
WALL TYPE
METAL STUD TO
BOTTOM OF
STRUCTURE
LINE OF CEILING 16 GYPSUM WALLBOARD
{ABUSE RESISTANT PANELS
16 CEMENT BACKER BOARD BEHIND
CERAMIC TILE ONLY}
METAL
STUDS LINE OF FLOOR
ACOUSTICAL SEALANT
SOUND
INSULATION
LINE OF STRUCTURAL
FLOOR OR ROOF DECK FIRE STOP
200 CONCRETE
MASONRY UNIT
LINE OF FLOOR
HORIZ JOINT
REINFORCING
CEILING AS SCHEDULED
FIRE RATING: 1 HR FR
60 METAL
STUDS EA. SIDE
200 CONCRETE
MASONRY UNIT
LINE OF FLOOR
GROUT FULL
HORIZ JOINT
REINFORCING
FIRE RATING: 1 HR FR FIRE RATING: NOT RATED
150 METAL STUD
LINE OF STRUCTURE
GROUT FULL
LINE OF
STRUCTURAL
DECK
METAL STUD TO BOTTOM
OF STRUCTURE
LINE OF CEILING
16 FIRE RATED GYPSUM
WALLBOARD
100 METAL CEE STUDS
LINE OF FLOOR
FIRE RATED SEALANT
SOUND INSULATION
GENERAL NOTES:
1.
SEE ROOM FINISH SCHEDULE FOR SPECIAL
FINISHES ON CONCRETE MASONRY UNITS.
3.
SEE PLANS FOR FIRE RATED WALL LOCATIONS AND HOURLY
RATED REQUIREMENTS.
4.
SEE STRUCTURAL FOR ALL VERTICAL WALL REINFORCING AND
ALL BOND BEAM REINFORCING IN MASONRY WALLS AND FOR
ALL REINFORCING IN CIP CONCRETE WALLS.
5.
PROVIDE ACOUSTICAL SEALANT AT WALL TYPES
INDICATED TO RECEIVE SOUND INSULATION.
6.
PROVIDE FIRE STOPPING AND FIRE RATED SEALANT AS
REQUIRED FOR ASSEMBLY INDICATED AT FIRE RATED WALLS.
7.
SEE PLANS FOR WALL THICKNESS NOT SHOWN ON THIS
DRAWING.
8.
PROVIDE CEMENT BACKER BOARD WHERE CERAMIC TILE IS
INDICATED IN LIEU OF GYPSUM BOARD WHERE WALL IS
SCHEDULED TO RECEIVE CERAMIC TILE FINISH, UNLESS NOTED
OTHERWISE FOR SPECIFIC WALL TYPE.
PROVIDE IMPACT RESISTANT PANELS IN LIEU OF GYPSUM
BOARD WHERE SCHEDULED.
NOTE
1. PROVIDE 19 EXTERIOR GRADE SHEATHING
AT EXTERIOR WALLS.
2. PROVIDE CONTINIOUS FIRE RATING BETWEEN
TRUSSES AS REQUIRED.
LINE OF STRUCTURAL
FLOOR OR ROOF DECK FIRE STOP
B1
SCALE: NTS
WALL TYPE
60 METAL
STUDS
LINE OF FLOOR
GROUT FULL
150 METAL
STUDS
200 CONCRETE
MASONRY UNIT
FIRE RATING: 1 HR FR
C2
SCALE: NTS
WALL TYPE
METAL STUD TO
BOTTOM OF
STRUCTURE
LINE OF CEILING
16 GYPSUM WALLBOARD
ABUSE RESISTANT PANELS
BEDROOM SIDE
100 METAL
STUDS
LINE OF FLOOR
ACOUSTICAL SEALANT
SOUND
INSULATION
LINE OF STRUCTURE
CHASE WALL
SCALE: NTS
WALL TYPE
LINE OF STRUCTURAL
FLOOR OR ROOF DECK FIRE STOP
200 CONCRETE
MASONRY UNIT
LINE OF FLOOR
HORIZ JOINT
REINFORCING
CEILING AS SCHEDULED
FIRE RATING: 1 HR FR
GROUT FULL
E
3 COAT STUCCO SYSTEM ON LATH
OVER FLUID APPLIED VAPOR BARRIER
16 GYPSUM
WALLBOARD
ABUSE RESISTANT
PANELS
BEDROOM SIDE
16 GYPSUM
WALLBOARD
ABUSE RESISTANT
PANELS
BEDROOM SIDE
16 GYPSUM
WALLBOARD
ABUSE RESISTANT
PANELS
BEDROOM SIDE
16 GYPSUM
WALLBOARD
ABUSE RESISTANT
PANELS
BEDROOM SIDE
60 METAL
STUDS/FURRING
16 GYPSUM
WALLBOARD
ABUSE RESISTANT
PANELS
BEDROOM SIDE
60 RIGID
INSULATION R19
FIRE RATING: 1 HR FR
DAMPPROOFING THIS SIDE
(MECH., ELEC. ROOM
60 METAL
STUDS/FURRING
STUCCO SYSTEM, METAL LATH
WITH SELF ADHERED MEMBRANE
60 RIGID
INSULATION R19
60 RIGID
INSULATION R19
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-601
U N
AC
C
O M
PA
N
IE
D
E N
L I
ST
ED
P
ER
SO
N N
EL
H
O U
SI
N
G M
O B I
LE
D
IS
T R
IC
T
T.
D
.W
T.
D
.W
C .A
J.
M
.C
FE
BR
U
AU
R Y
W
9R
M
7E U
M
7E C
AMENDMENT 0002
SO
TO
C
AN
O A
IR
B
AS
E, H O
N D
U R
AS
M O
BI
LE
, A
LA
BA
M
A
W
AL
L
TY
P E S
M
AR
K D
AT
E
AM
EN
D
M
EN
T
/2
8/
C
H
AN
G
ED
W
AL
L
TY
PE
D
ET
AI
LS
A
AS
S
C H
ED
U
LE
D
AS
SCHED
AS
S
C H
ED
U
LE
D
AS
SCHED
M
FR
ST
D
MFR
STD
AS
S
C H
ED
U
LE
D
AS
SCHED 10
AS
S
C H
ED
U
LE
D
AS
SCHED 50
DOOR TYPES DOOR FRAMES
WINDOW TYPES
F N 100x625 1 2
INSULATED GLAZING UNIT, SEE
GLAZING SPEC. 08 81 00.
FIRE GLASS @ FIRE
RATED ASSEMBLY, SEE
GLAZING SPEC. 08 81 00
A
MANUF. CAM
HARDWARE
LOCK
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-603
U N
AC
C
O M
PA
N
IE
D
E N
L I
ST
ED
P
ER
SO
N N
EL
H
O U
SI
N
G M
O B I
LE
D
IS
T R
IC
T
T.
D
.W
T.
D
.W
C .A
J.
M
.C
FE
BR
U
AU
R Y
W
9R
M
7E U
M
7E C
AMENDMENT 0002
SO
TO
C
AN
O A
IR
B
AS
E, H O
N D
U R
AS
M O
BI
LE
, A
LA
BA
M
A
FI
R
ST
F
LO
O
R D
O O
R S
C H
ED
U
L E
USACE_DOOR SCHEDULE FIRST FLOOR
DOOR NO. TYPE
DOOR
FIRE
RATING HARDWARE
FRAME
COMMENTS:
SIZE
MATERIAL FINISH TYPE MATERIAL FINISH
DETAILS
WIDTH HEIGHT THICKNESS HEAD JAMB SILL
101 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
102 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
103 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
104 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
105A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 105B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT
106 A 350 500 50 STEEL PAINTED 1/2HR - STEEL PAINTED - - - CAM LOCK BY MANUF.
107 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
108 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
109 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
110 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
111A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 111B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT
112 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL PAINTED - - - CAM LOCK BY MANUF.
113 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
114 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
115 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
116A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 116B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT
117 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
118 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL PAINTED - - - CAM LOCK BY MANUF.
119 F 900 2,100 50 HM PAINTED 1/2HR HW-1 1 HM PAINTED 1/A607 2/A607 8/A607
120 F 800 2,100 50 WD PAINTED 1/2HR HW-4 1 HM PAINTED 3/A607 4/A607 9/A607
121 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM PAINTED 3/A607 4/A607 9/A607
122 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
123 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
124 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
125 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
126A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 126B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT
127 A 350 500 50 STEEL PAINTED 1/2HR - STEEL PAINTED - - - CAM LOCK BY MANUF.
128 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
129 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
130 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
131 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
132A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 132B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT
133 A 350 500 50 STEEL PAINTED 1/2HR - STEEL PAINTED - - - CAM LOCK BY MANUF.
134 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
135 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
136 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
137 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
138A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 138B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT
139 A 350 500 50 STEEL PAINTED 1/2HR - STEEL PAINTED - - - CAM LOCK BY MANUF.
140A N 900 2,100 50 HM PAINTED 1/2 HR HW-2 1 HM PAINTED 1/A607 2/A607 7/A607
140B N 900 2,100 50 HM PAINTED 1/2 HR HW-2 1 HM PAINTED 1/A607 2/A607 7/A607
141 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL PAINTED - - - CAM LOCK BY MANUF.
142A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 142B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT
143 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
144 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
145 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
146 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
147 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL PAINTED - - - CAM LOCK BY MANUF.
148A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 148B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT
149 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
150 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
151 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
152 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED
153 A 350 500 50 STEEL PAINTED 1/2HR - STEEL PAINTED - - - CAM LOCK BY MANUF.
154 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
155 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
156 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
157 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
158A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 158B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT
159 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM PAINTED 3/A607 4/A607 9/A607
160 F 800 2,100 50 WD PAINTED 1/2HR HW-3 1 HM PAINTED 3/A607 4/A607 9/A607
161 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM PAINTED 3/A607 4/A607 9/A607
162 F 900 2,100 50 HM PAINTED 1/2HR HW-1 1 HM PAINTED 1/A607 2/A607 9/A607
163 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL PAINTED - - - CAM LOCK BY MANUF.
164 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
165 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
166 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
167 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
168A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 168B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT
169 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL PAINTED - - - CAM LOCK BY MANUF.
170 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
171 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
172 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
173 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
174A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 174B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT
175 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL PAINTED - - - CAM LOCK BY MANUF.
176 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
177 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
178 F 800 2,100 50 WD PAINTED - HW-8 2 HM PAINTED 5/A607 6/A607 9/A607
179 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM PAINTED 3/A607 4/A607 9/A607
180A F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT 180B F 800 2,100 50 WD PAINTED - HW-7 2 HM PAINTED 5/A607 6/A607 9/A607 1/2" UNDERCUT
USACE_DOOR SCHEDULE RISER ROOM
DOOR NO. TYPE
DOOR
FIRE
RATING HARDWARE
FRAME
COMMENTS:
SIZE
MATERIAL FINISH TYPE MATERIAL FINISH
DETAILS
WIDTH HEIGHT THICKNESS HEAD JAMB SILL
01 25 1,800 2,100 44 HM PAINTED 1 HM PAINTED FULLY LOUVERED
1 M
AR
K D
AT
E
AM
EN
D
M
EN
T
/2
8/
G R
ID
W
IN
D
O W
T
YP
E
AN
D D
O O
R C
O M
M
EN
T
S
C H
ED
U
LE
D
AS
SCHED
AS
S
C H
ED
U
LE
D
AS
SCHED
M
FR
ST
D
MFR
STD
AS
S
C H
ED
U
LE
D
AS
SCHED 10
AS
S
C H
ED
U
LE
D
AS
SCHED 50
DOOR TYPES DOOR FRAMES
WINDOW TYPES
F N 100x625 1 2
INSULATED GLAZING UNIT, SEE
GLAZING SPEC. 08 81 00.
FIRE GLASS @ FIRE
RATED ASSEMBLY, SEE
GLAZING SPEC. 08 81 00
A
MANUF. CAM
HARDWARE
LOCK
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-604
U N
AC
C
O M
PA
N
IE
D
E N
L I
ST
ED
P
ER
SO
N N
EL
H
O U
SI
N
G M
O B I
LE
D
IS
T R
IC
T
T.
D
.W
T.
D
.W
C .A
J.
M
.C
FE
BR
U
AU
R Y
W
9R
M
7E U
M
7E C
AMENDMENT 0002
SO
TO
C
AN
O A
IR
B
AS
E, H O
N D
U R
AS
M O
BI
LE
, A
LA
BA
M
A
SE
C
O N
D F
LO
O
R D
O O
R S
C H
ED
U
LE
USACE_DOOR SCHEDULE SECOND FLOOR
DOOR NO. TYPE
DOOR
Finish
FIRE
RATING HARDWARE
FRAME
COMMENTS:
SIZE
MATERIAL TYPE MATERIAL
DETAILS
WIDTH HEIGHT THICKNESS HEAD JAMB SILL
201 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
202 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
203 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
204 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
205A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
205B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
206 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
207 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
208 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
209 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
210 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
211A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
211B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
212 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
213 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
214 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
215 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
216 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
217A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
217B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
218 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
219 F 900 2,100 50 HM PAINTED 1/2HR HW-3 1 HM 3/A607 4/A607 9/A607
220 F 800 2,100 50 WD PAINTED 1/2HR HW-4 1 HM 3/A607 4/A607 9/A607
221 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM 3/A607 4/A607 9/A607
222 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
223 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
224 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
225 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
226A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
226B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
227 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
228 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
229 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
230 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
231 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
232A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
232B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
233 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
234 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
235 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
236 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
237 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 1/A607 4/A607 9/A607
238A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
238B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
239 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
240A N 900 2,100 50 HM PAINTED 1/2 HR HW-4 1 HM 1/A607 2/A607 7/A607
240B N 900 2,100 50 HM PAINTED 1/2 HR HW-4 1 HM 1/A607 2/A607 7/A607
241 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
242A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
242B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
243 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
244 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
245 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
246 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
247 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
248A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
248B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
249 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
250 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
251 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
252 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
253 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
254 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
255 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
256 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
257 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
258A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
258B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
259 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM 3/A607 4/A607 9/A607
260 F 800 2,100 50 WD PAINTED 1/2HR HW-3 1 HM 3/A607 4/A607 9/A607
261 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM 3/A607 4/A607 9/A607
262 B 900 2,100 50 HM PAINTED - HW-9 1 HM 3/A607 4/A607 9/A607
263 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
264 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
265 F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607
266 F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607
267 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
268A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
268B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
269 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
270 F 900 2,100 50 WD PAINTED 1/2HR HW-6 HM 3/A607 4/A607 9/A607
271 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
272 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
273 F 900 2,100 50 WD PAINTED 1/2HR HW-6 HM 3/A607 4/A607 9/A607
274A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
274B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
275 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
276 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
277 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
278 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
279 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
280A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
280B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
M
AR
K D
AT
E
AM
EN
D
M
EN
T
/2
8/
G R
ID
W
IN
D
O W
T
YP
E
AN
D D
O O
R C
O M
M
EN
S
C H
ED
U
LE
D
AS
SCHED
AS
S
C H
ED
U
LE
D
AS
SCHED
M
FR
ST
D
MFR
STD
AS
S
C H
ED
U
LE
D
AS
SCHED 10
AS
S
C H
ED
U
LE
D
AS
SCHED 50
DOOR TYPES DOOR FRAMES
WINDOW TYPES
F N 100x625 1 2
INSULATED GLAZING UNIT, SEE
GLAZING SPEC. 08 81 00.
FIRE GLASS @ FIRE
RATED ASSEMBLY, SEE
GLAZING SPEC. 08 81 00
A
MANUF. CAM
HARDWARE
LOCK
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-605
U N
AC
C
O M
PA
N
IE
D
E N
L I
ST
ED
P
ER
SO
N N
EL
H
O U
SI
N
G M
O B I
LE
D
IS
T R
IC
T
T.
D
.W
T.
D
.W
C .A
J.
M
.C
FE
BR
U
AU
R Y
W
9R
M
7E U
M
7E C
AMENDMENT 0002
SO
TO
C
AN
O A
IR
B
AS
E, H O
N D
U R
AS
M O
BI
LE
, A
LA
BA
M
A
TH
IR
D F
LO
O
R D
O O
R S
C H
ED
U
L E
USACE_DOOR SCHEDULE THIRD FLOOR
DOOR NO. TYPE
DOOR
Finish
FIRE
RATING HARDWARE
FRAME
COMMENTS:
SIZE
MATERIAL TYPE MATERIAL
DETAILS
WIDTH HEIGHT THICKNESS HEAD JAMB SILL
301 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
302 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
303 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
304A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
304B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
305 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
306 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
307 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
308 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
309 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
310 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
311A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
311B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
312 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
313 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
314 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
315 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
316A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
316B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
317 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
318 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
319 F 900 2,100 50 HM PAINTED 1/2HR HW-3 1 HM 3/A607 4/A607 9/A607
320 F 800 2,100 50 WD PAINTED 1/2HR HW-4 1 HM 3/A607 4/A607 9/A607
321 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM 3/A607 4/A607 9/A607
322 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
323 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
324 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
325 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
326A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
326B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
327 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
328 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
329 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
330 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
331 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
332A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
332B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
333 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
334 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
335 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
336 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
337 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
338A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
338B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
339 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
340A N 900 2,100 50 HM PAINTED 1/2 HR HW-2 1 HM 1/A607 2/A607 7/A607
340B N 900 2,100 50 HM PAINTED 1/2 HR HW-2 1 HM 1/A607 2/A607 7/A607
341 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
342A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
342B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
343 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
344 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
345 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
346 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
347 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
348 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
349A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
349B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
350 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
351 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
352 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
353 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
354 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
355 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
356 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
357 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
358A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
358B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
359 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM 3/A607 4/A607 9/A607
360 F 800 2,100 50 WD PAINTED 1/2HR HW-3 1 HM 3/A607 4/A607 9/A607
361 F 900 2,100 50 WD PAINTED 1/2HR HW-5 1 HM 3/A607 4/A607 9/A607
362 B 900 2,100 50 HM PAINTED - HW-9 1 HM 3/A607 4/A607 9/A607
363 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
364 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607
365 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
366 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
367 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
368A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
368B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
369 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
370 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
371 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
372 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
373 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
374A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
374B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
375 A 350 500 50 STEEL PAINTED 1/2HR - - STEEL - - - CAM LOCK BY MANUF.
376 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
377 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
378 F 800 2,100 50 WD PAINTED - HW-8 2 HM 5/A607 6/A607 9/A607
379 F 900 2,100 50 WD PAINTED 1/2HR HW-6 1 HM 3/A607 4/A607 9/A607
380A F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
380B F 800 2,100 50 WD PAINTED - HW-7 2 HM 5/A607 6/A607 9/A607 1/2" UNDERCUT
M
AR
K D
AT
E
AM
EN
D
M
EN
T
/2
8/
G
R
ID
W
IN
D O
W T
YP
E
AN
D
D O
O R
C O
M M
EN
1/2"
9"
9"
3/ 4"
3/ 4"
6" 3/
4"
1/ 2"
3/ 4"
SIGN TYPE - A
MECHANICAL
ROOM
9"
SIGN TYPE - E
EXIT
1" 1"
1"
3"
Accounting and Finance Officer Military Pay Civilian Pay Travel Pay Commercial Services Document Section
Administration Communications Branch
Central Base Administration Base Locator Documentation Branch Administration Orders Branch Publications Branch Master Reference Library
Civilian Personnel Office Staffing Section Employee Regulations Sections
Classification Section Labor Relation Section Data Management Support
Commander Deputy Commander Executive Officer Senior Enlisted Advisor Administration Conference Room
Director of Personnel Chief of Military Personnel Customer Services Air Force Aid Society Chief Civilian Personnel Placements and Applications Staffing Section Employee Regulations Sections304
116 137
3/4"
3/4"
3/ 4"
3/4" 3' - 10 1/2" 3/4" 4' - 0"
3'
0"
2'
1/
4" 9"
3/ 4"
Building Title
SIGN TYPE - F
3/ 4"
10"
7"
SIGN TYPE - G
"RESTRICTED AREA"
THIS ACTIVITY HAS BEEN DECLARED A RESTRICTED AREA
BY AUTHORITY OF THE INSTALLATION COMMANDER IN
ACCORDANCE WITH THE PROVISIONS OF THE DIRECTIVE
ISSUED BY THE SECRETARY OF DEFENSE ON 10
THE COMMANDER.
DEADLY FORCE IS AUTHORIZED.
DECEMBER 2005, PURSUANT TO THE PROVISIONS OF
SECTION 21, INTERNAL SECURITY ACT OF 1950.
UNAUTHORIZED ENTRY IS PROHIBITED.
ALL PERSONS AND VEHICLES ENTERING HEREIN ARE
LIABLE TO SEARCH. PHOTOGRAPHY OF THE FACILITIES IS
PROHIBITED WITHOUT SPECIFIC AUTHORIZATION FROM
NOTE: BACKGROUND SHALL MATCH GENERAL WALL
PAINT IN COLOR, TITLE SHALL BE MANUFACTURER'S
STANDARD RED, ALL OTHER TEXT SHALL BE BLACK.
1/2" HIGH TEXT
3/8" HIGH TEXT
10"
7"
SIGN TYPE - H
THIS FACILITY IS
PROTECTED BY AN
ALARM SYSTEM
Unauthorized entry is prohibited. Violators will be prosecuted under the provisions of the UCMJ or other applicable laws.
9 1/2"
1/
4"
1/ 4"
YELLOW BACKGROUND
1/2" HIGH BLACK TEXT
1" HIGH YELLOW TEXT
BLACK BACKGROUND
3/8" HIGH BLACK TEXT
9"
/2
SIGN TYPE - J
STAIR
EXIT
1" 1"
1/ 2"
1" 1"
6"
10"
7"
SIGN TYPE - M
WITHIN
50 FEET OF
BUILDING
NO SMOKING
NOTE: SIGN SHALL BE POSTED PER
AR 600-63.
1/
4"
1/ 2"
1"
1/ 4"
1' - 0"
8"
SIGN TYPE - N
IN CASE OF
EMERGENCY CALL
DPW WORK CENTER
AT (719) 526-5345
US Army Corps of Engineers ®
SHEET ID
U.
S.
A
RM
Y
CO
RP
S
O F
EN
G
IN
EE
RS
DR
A W
N
BY
DE
S I
G
NE
D
BY
SU
B M
IT
TE
D
BY
SI
ZE
CH
E C
KE
D
B Y
AN
S I
D
FI
LE
N
AM
E:
IS
SU
E
DA
TE
CO
N T
RA
CT
N O
SO
L I
CI
TA
TI
O
N
NO
PR
O
JE
CT
N
UM
BE
R :
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
DE
SC
RI
PT
IO
N
I-400
UN
AC
C O M
PA
N I
ED
E
NL
IS
TE
D
P E
RS
O N N
EL
H
O
US
IN
G
M O
BI
LE
D
IS
T R
IC
T T.
D.
W
T.
D.
W
C.
A.
J.
M
.C
FE
BR
UA
RY
W
9R
M
7E U4
M
7E U4
AMENDMENT 0002
SO
TO
C
AN
O A
IR
B
AS
E, H O
ND
UR
AS
SA
IN
T
JO
SE
P H
S
TR
EE
T
M O
B I
LE
A L
3 6
T Y
PI
CA
L
SI
G
NA
G
E
1. OVERALL SIGN SIZE VARIES DEPENDENT ON NUMBER OF LINES OF TEXT.
2 SEE SPEC SECTIONS 10-14-02 FOR SIGNAGE SCHEDULE.
GENERAL NOTES:
R
EV
IS
ED
N O
TE
M
AR
K
DA
TE
AM
EN
D
M
EN
T
/2
8/
1. THE ENTIRE BUILDINGS SHALL BE FULLY PROTECTED BY AUTOMATIC FIRE SUPPRESSION SYSTEMS INSTALLED IN ACCORDANCE WITH NFPA 13R, NFPA 13, UFC-3-600-01, AND BASE SPECIFIC CRITERIA. THE SYSTEM TYPES SHALL BE WET, DRY, AGENT AS INDICATED, UNLESS REQUIRED OTHERWISE BY CODE OR BASE CRITERIA.
2. THE FIRE SUPPRESSION SYSTEMS SHALL BE DESIGNED, INSTALLED AND TESTED IN ACCORDANCE WITH THE
FOLLOWING CRITERIA:
A. UFC-3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES.
B. NFPA-13R STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS.
3. THE SPRINKLER SYSTEMS SHALL BE HYDRAULICALLY CALCULATED IN ACCORDANCE WITH NFPA-13. DESIGN DENSITIES AND HOSE STREAM ALLOWANCE SHALL BE AS IDENTIFIED IN THE TABLE ON THIS SHEET:
4. MAXIMUM AREA OF COVERAGE PER SPRINKLER SHALL BE IN ACCORDANCE WITH UFC-3-600-01 FOR THE APPLICABLE
HAZARD AND TYPE OF SPRINKLER, OR IN ACCORDANCE WITH MANUFACTURER'S LISTINGS.
5. QUICK RESPONSE SPRINKLERS SHALL BE USED THROUGHOUT, EXCEPT IN ROOMS OR AREAS FOR WHICH QUICK RESPONSE SPRINKLERS ARE NOT LISTED, OR WHERE THEIR USE HAS BEEN SPECIFICALLY PROHIBITED BY THE
UFC
6. ALL FIRE PROTECTION SYSTEM CONTROL VALVES SHALL BE PROVIDED WITH SUPERVISORY SWITCHES BY THE SPRINKLER CONTRACTOR. ALL ELECTRICAL DEVICES FOR THE FIRE PROTECTION SYSTEM SHALL BE COMPATABLE
WITH THE FIRE ALARM SYSTEM.
7. PIPING SHALL BE INSTALLED SO THAT ALL PORTIONS OF THE SYSTEM CAN BE DRAINED BACK THROUGH VALVES IN
ACCORDANCE WITH THE REFERENCED NFPA STANDARDS.
8. ALL FIRE WALL PENETRATIONS SHALL BE MADE WITH UL APPROVED FIRESTOPPING SYSTEMS LISTED TO MAINTAIN
THE FIRE RATING OF THE WALLS IN WHICH THEY ARE INSTALLED.
9. INSPECTOR'S TEST VALVE TO BE PIPED FROM END OF LAST BRANCH LINE WITH NO EXPOSED PIPE IN FINISHED
SPACES.
10. FULLY COORDINATE INSTALLATION OF PIPE WITH ALL OTHER TRADES, WITH PARTICULAR EMPHASIS ON COORDINATION WITH HVAC DUCTWORK. SPRINKLER PIPE SHALL NOT BE SUSPENDED FROM DUCT HANGERS UNLESS THESE SUPPORTS ARE SPECIFICALLY DESIGNED TO ACCOMMODATE SPRINKLER PIPE. HANGERS SHALL BE IN ACCORDANCE WITH NFPA 13. NO OTHER SYSTEM SHALL BE SUPPORTED FROM SPRINLER PIPING.
11. FIRE DEPARTMENT CONNECTION FOR THE SPRINKLER SYSTEM SHALL BE PROVIDED WITH NAME PLATES PERMANENTLY ATTACHED TO IDENTIFY THE SYSTEM TYPE AND BUILDING SERVED, IN ACCORDANCE WITH APPLICABLE
REQUIREMENTS OF NFPA 13.
12. ALL SPRINKLER PIPING SHALL BE SCHEDULE 40 BLACK STEEL.
FIRE SUPPRESSION NOTES
13. FIRE FLOW TEST DATA:
STATIC PRESSURE: 303 kPa RESIDUAL PRESSURE: 207 kPa FLOW: 102 lps
DATE: 14 MAR 2018
(44 PSI)
(30 PSI)
(1619 GPM)
PERFORM A CONFIRMING FLOW TEST IN ACCORDANCE WITH NFPA 291 AND
USE DATA OBATINED FOR FINAL DESIGN.
PRESSURE GAUGES INDICATOR
THRUST BLOCK
FROM
FIRE PUMP
HOUSE
914 MM
INSULATING FLANGE
M M
DRAIN LINE
FIRE DEPT.
CONNECTION
MM
(TYP.)
UL
MIN
STEEL PIPING
(TYP)
GATE VALVE
ALARM
CHECK
VALVE
CHECK
VALVE
WATERFLOW
SPRINKLER SYSTEM
TO WET-PIPE
FIRE SUPPRESSION HAZARD SCHEDULE
ALLOWANCE
MECH RM, 232.3 SQ M WET PIPE
AREA
AREA OF
OPERATIONRATING
HAZARD
DENSITY SYSTEM
TYPE OF
SYMBOLSTREAM
HOSE
DORMS 4 SPRINKLESRESIDENTIAL 2.0 LPM/SQ M WET PIPE 15.8 LPS
OHJANITORS CLOSET
RH
15.8 LPS
ORDINARY
HAZARD 8.0 LPM/SQ M
AREAS
ALL OTHER 139.4 SQ M
HAZARD
LIGHT 4.0 LPM/SQ M WET PIPE 15.8 LPS LH
TO SPRINKLER
SYSTEM
BALL VALVE (TYP)
SIGHT GLASS
ORIFICE SIZED FOR FLOW OF
SMALLEST SPRINKLER HEAD ON
FLOOR.
6" COMBINATION SPRINKLER/
STANDPIPE RISER
2" DRAIN RISER
INSPECTOR'S TEST AND
DRAIN CONNECTION
US Army Corps of Engineers ®
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
M O
BI
LE
, A L
FX001
UN
AC
C O M
PA
N I
ED
E
NL
IS
TE
D
P E
RS
O N N
EL
H
O
US
IN
G
M O
B I
LE
D
IS
T R
IC
T R
.P
ER
SO
N
EN
-D
E
W .K
N
AP
P
B.
D
U R
H
AM
FE
BR
U
AR
Y
W
9R
M
7E U
M
7E U
SO
TO
C
AN
O A
IR
B
AS
E, H O
ND
UR
AS
F I
RE
S U P
PR
E S
SI
O
N
M
AR
K D
AT
E
AM
M
EN
D .0
/2 9/
N.T.S.
1 WET PIPE RISER N.T.S.
2 SPRINKLER FLOOR ZONE VALVE DETAIL
AD
D
ED
F
LO
O
R Z
O N
E
VA
LV
E
D
ET
AI
L
AMENDMENT 0002
P
SP SP
SP
SP SP
SP SP
SP SP
SP SPSP
LOC
P P P PTE
XT
KEY PLAN
A B
CORR
MECH
LAUNDRY
ELEC
DORM
CLOSET
CLOSET
MECH
DORM
DORM
CLOSET
CLOSET
MECH
DORM
DORM
CLOSET
CLOSET
MECH
DORM
DORM
CLOSET
CLOSET
MECH
DORM
DORM
CLOSET
CLOSET
MECH
DORM
CLOSET
CLOSET
MECH
BATHROOM
BATHROOM
BATHROOM
BATHROOM
BATHROOM
BATHROOM
DORM
DORM
WP
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
FA103
U N
AC
C
O M
PA
N
IE
D
E N
L I
ST
ED
P
ER
SO
N N
EL
H
O U
SI
N
G M
O B I
LE
D
IS
T R
IC
T
R .M
.F O
R
TN
ER
EN
-D
E
W .J
. K N
AP
P
D .D
. C O
LL
IE
R
FE
B R
U
AR
Y
W
9R
M
7E U
M
7E U
SO
TO
C
AN
O A
IR
B
AS
E, H O
N D
U R
AS
M O
BI
LE
, A
LA
BA
M
A
S E C
O N
D F
L O O
R F
IR
E
A L
AR
M
M A S
S N
O
TI
FI
C
AT
IO
N
PL
AN
AR
E A
"A
PLAN NORTH
SCALE:
0 40002000
1 : 50
1 : 501 SECOND FLOOR FIRE ALARM & MASS NOTIFICATION PLAN - AREA "A"
M
AR
K D
AT
E
AM
E N D
.0
3 /
/2
AD
D
ED
T
AM
PE
R A
N D
F
LO
W S
W
IT
C H
ES
P
SP SP
SP
SP SP
SP SP
SP SP
SP SPSP
LOC
P P P P
TE
XT
KEY PLAN
A B
CORR
MECH
LAUNDRY
ELEC
DORM
CLOSET
CLOSET
MECH
CLOSET
CLOSET
MECH
DORM
CLOSET
CLOSET
MECH
DORM
CLOSET
CLOSET
MECH
DORM
CLOSET
CLOSET
MECH
DORM
CLOSET
CLOSET
MECH
BATHROOM
BATHROOM
BATHROOM
BATHROOM
BATHROOM
BATHROOM
DORM
DORM
DORM
DORM
DORM
DORM
373DORM
WP
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
FA105
U N
AC
C
O M
PA
N
IE
D
E N
L I
ST
ED
P
ER
SO
N N
EL
H
O U
SI
N
G M
O B I
LE
D
IS
T R
IC
T
R .M
.F O
R
TN
ER
EN
-D
E
W .J
. K N
AP
P
D .D
. C O
LL
IE
R
FE
B R
U
AR
Y
W
9R
M
7E U
M
7E U
SO
TO
C
AN
O A
IR
B
AS
E, H O
N D
U R
AS
M O
BI
LE
, A
LA
BA
M
A
TH
IR
D F
LO
O
R F
I R E
AL
AR
M
M
AS
S N
O T I
FI
C
A T
IO
N
PL
AN
AR
E A
"A
PLAN NORTH
SCALE:
0 40002000
1 : 50
1 : 501 THIRD FLOOR FIRE ALARM & MASS NOTIFICATION PLAN - AREA "A"
M
AR
K D
AT
E
AM
E N D
.0
3 /
/2
AD
D
ED
T
AM
PE
R A
N D
F
LO
W S
W
IT
C H
ES
ALL FLOOR DRAINS SHALL HAVE TRAP PRIMER CONNECTIONS AND SHALL BE SUPPLIED FROM
AUTOMATIC TRAP PRIMERS CONNECT TO THE NEAREST SINK. RUN 1/4" SOFT COPPER TUBING
FROM TRAP PRIMERS TO FLOOR DRAIN TRAP PRIMER CONNECTION. TRAP PRIMERS SHALL BE
EQUAL TO ZURN "SANI-GUARD" MODEL Z-1022.
CONTRACTOR SHALL FURNISH AND INSTALL WATER SHOCK ARRESTERS EQUAL TO ZURN
SHOKTROL AS SHOWN ON PLANS AND AS PER MANUFACTURER'S RECOMMENDATIONS. AIR
CHAMERS SHALL NOT BE SUBSTITUTED FOR FACTORY FABRICATED WATER SHOCK ARRESTORS.
ALL PIPING SHALL BE FIRMLY ANCHORED AND SUPPORTED TO PREVENT SWAY AND VIBRATION THE ENTIRE
LENGTH.
ALL COPPER WATER LINE PENETRATIONS THROUGH WALLS SHALL BE SLEEVED.
UNLESS INDICATED OTHERWISE, ALL BELOW SLAB COLD WATER AND HOT WATER PIPING SHALL BE TYPE "K"
COPPER.
UNLESS INDICATED OTHERWISE, ALL ABOVE SLAB COLD WATER AND HOT WATER PIPING SHALL BE TYPE "L" COPPER TUBING IN ACCORDANCE WITH ASTM B 88. PIPE FIITINGS SHALL BE COPPER OR COPPER ALLOY IN
ACCORDANCE WITH ASME 16.22.. JOINTS SHALL BE SOLDER ACCORDANCE WITH ASTM B 828
USING "LEAD FREE" SOLDER IN COMPLIANCE WITH ASTM B 32.
INSULATE ALL EXPOSED PIPES AND SURFACES UNDER ACCESSIBLE LAVATORIES AND COUNTER
SINKS PER ADA 4.19.4 AND ANSI-A117.1. PROVIDE ONE PIECE PROTECTOR WITH FULL ROTATION OPTION CONSISTING OF INTERNAL GROOVE LOCKING RING FOR NON SEPERATION AND EXTERNAL LOCKING RING WITH STAINLESS STEEL SECURITY SCREW TO INSURE EXTRA LONG TERM TAMPER RESISTANCE ANTIMICROBIAL U.V. INHIBITED UNIVERSAL FIT, 3-M DUAL LOCK (TM) FASTENERS
SECURED WITH SELF LOCKING APPROVED NYLON STRAPS. FURNISH ONE PIECE VALVE/ANGLE
STEP PROTECTOR. ONE PIECE OFFSET PROTECTOR AND ONE PIECE P-TRAP PROTECTOR.
PRO-XTREME BY PLUMBEREX.
SET WATER HEATER THERMOSTAT TO PREVENT PROMOTION OF LEGIONELLA. FURNISH
TEMPERING MIXING VALVE TO PROVIDE 43.3°C WATER AT THE PLUMBING FIXTURES.
AND SMALLER AND 1 MM PER M (1%) FOR PIPES 75 MM AND LARGER.
PROVIDE 305 x305 ACCESS DOORS ON ALL NON-ACCESSIBLE CEILINGS AND WALLS
PIPE ALL P&T VALVES FROM WATER HEATERS TO OUTSIDE OF BUILDING USING
SEAL ALL PENETRATIONS OF FIRE RATED PARTITIONS WITH FIRE RATED STOPPING MATERIAL.
PROVIDE DIELECTRIC UNIONS AT ALL CONNECTIONS OF DISSIMILAR METALS.
ALL SOIL, WASTE, AND VENT PIPING SHALL BE SLOPED 21 MM PER M (2%) FOR PIPES 2 1/2"
INSULATE ALL HOT WATER PIPING, TEMPERED WATER PIPING AND HOT WATER RECIRCULATING PIPING WITH 1 1/2"
ESCUTCHEON PLATES AT THE WALL, FLOOR OR CEILING PENETRATIONS.
ALL EXPOSED PIPING AT PLUMBING FIXTURES SHALL BE CHROME PLATED BRASS WITH
ALL PIPING SHALL BE CONCEALED WITHIN THE CEILING SPACE, WALLS AND CHASES AS SHOWN
REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ALL
INSTALL ALL WATER, WASTE AND VENT PIPING IN ACCORDANCE WITH ALL APPLICABLE CODES.
COORDINATE WORK WITH ALL OTHER TRADES TO AVOID INTERFERENCES.
PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL VERIFY ALL EXISTING BUILDING
ALL SHUT-OFF VALVES SHALL BE BALL VALVES.
FURNISH SUPPLIES WITH STOP VALVES FOR ALL PLUMBING FIXTURES.
13.
11.
28.
FOR VALVES
FULL SIZE COPPER PIPING.
29.
16.
26.
25.
24.
23.
22.
21.
20.
19.
18.
17.
15.
14.
12.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
PLUMBING GENERAL NOTES
ALL WATER PIPING SHALL BE SLOPED TO DRAIN.
ON PLANS.
PLUMBING FIXTURES.
CONDITIONS.
ALL WORK SHALL CONFORM WITH UFC 3-420-01 AND ALL OTHER APPLICABLE CODES AND
STANDARDS.
ALL HANDICAP FIXTURES SHALL BE MOUNTED IN ACCORDANCE WITH THE AMERICANS WITH
DISABILITIES ACT (ADA) AND ALL OTHER PERTINENT ACCESSIBILITY CODE FOR BUILDING
CONSTRUCTION.
PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL VERIFY EXACT LOCATIONS OF UTILITIES IN FIELD.
SOIL, WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC IN ACCORDANCE WITH ASTM D 2665.
PVC PIPE FITTINGS SHALL BE IN ACCORDANCE WITH ASTM D 3311. JOINTS SHALL BE SOLVENT
CEMENTED IN ACCORDANCE WITH ASTM D 2855 USING SOLVENT CEMENT IN COMPLIANCE WITH
ASTM D 2564.
30. ALL FLOOR CLEAN OUT PLUGS SHALL BE PVC.
FIBERGLASS INSULATION PER SPECIFICATIONS.
FURNISH RELAYS NECESSARY FOR THE DDC CONTROL SYSTEM TO CONTROL THE WATER
HEATER AND THE HOT WATER RECALCULATION PUMP.
***31. THE ENTIRE SOLAR WATER HEATING SYSTEM IS BID OPTION #1. THIS INCLUDES, BUT NOT LIMIT TO, SOLAR COLLECTORS, SOLAR PUMPS SP-1 &SP-2, SOLAR STORAGE TANK, AND DRAIN BACK TANK.
PLUMBING FIXTURE SCHEDULE
SUPPLY SIZE (mm)
MM
WASTE
HOT COLD
FIXTURESNO. DESCRIPTION
COORDINATE PLUMBING PIPING WITH HVAC DUCTS AND ELECTRICAL CONDUIT.
GENERAL NOTES
SEE ARCHITECTURAL PLANS FOR LOCATION OF ALL PLUMBING FIXTURES1 - ALL VENTS THRU ROOF (VTR) SHALL BE OFFSET A MINIMUM OF 4.6m
ALL WATER PIPING SHALL BE RUN ABOVE CEILING UNLESS OTHERWISE NOTED.2
FROM ALL OUTSIDE INTAKES.
-3
HC - HANDICAPPED
MM
VENT
PROVIDE INSULATING COVER FOR ALL EXPOSED DRAIN AND WATER4 -
PIPING FOR H.C. ACCESSIBLE LAVATORIES.
PRESSURE BALANCED SINGLE LEVER MIXING VALVE WITH STOPS,
100 15--P1
75 15 15P3
FLOOR DRAINFD-1 75 -- -- FLOOR DRAIN W/ SQUARE TOP AND TRAP PRIMER CONNECTION.
LAUNDRY BOXP5 50 15 15 20 GAUGE HOT DIPPED GALVANIZED STEEL LAUNDRY BOX WITH VALVES, DRAIN, AND ARRESTORS. FIRE RATED CONSTRUCTION.
WATER CLOSET
SHOWER
P2
ELONGATED SEAT, CLOSED FRONT W/ COVER, STAINLESS STEEL POSTS. ANGLE STOPS. CLOSET RISER.
VITREOUS CHINA FLOOR MOUNTED, SIPHON JET, TANK TYPE, BOTTOM OUTLET, WHITE VITREOUS CHINA, ELONGATED BOWL. (4.8 L PER FLUSH)
COUNTERTOP LAVATORY 1532 50 15 40mm, 17GA. P-TRAP. SUPPLIES W/ ANGLE STOPS.
A.D.A. COMPLIANT FAUCET, SINGLE CONTROL, POP UP DRAIN AND LIFT ROD IN BRUSHED SATIN FINISH, AND 1.9L/min (0.5 GPM) RESTRICTOR.
500mmX450mm, VITREOUS CHINA COUNTERTOP, 100mm CENTERS, SELF RIMMING, FRONT OVERFLOW.
WALL HYDRANTP4 - - 15
PERMANENT STAINLESS STEEL SEAT, ADJUSTABLE TEFLON IMPREGNATED PACKING NUT, STANDARD O SEAT WASHER, SINGLE KEY OPERATION,
- VACUUM BREAKER CAP & BODY.
SERVICE SINKP7 75 15 15 SEE SPECIFICATIONS.50
DRINKING FOUNTAIN
WH
HUB DRAIN
FLOOR DRAIN (FD)
INCREASER
HOSE BIBB (HB)
SILL COCK (SC)
CHECK VALVE
BALANCE VALVE UNLESS NOTED OTHERWISE
NOT TO SCALE
ABOVE CEILING
CLEANOUT (C.O.)
UNION
NTS
AC
UNO
E.C.O.
D.F.
F.C.O.
EXTERIOR CLEANOUT
FLOOR CLEANOUT
WATER HAMMER
SANITARY SEWER
HOT WATER
COLD WATER
SS
(44°C)
PLUMBING LEGEND
GLOBE VALVE
GATE VALVE
TRAP PRIMER
VENT
SOIL , WASTE
T
FD
DN
WHA " "
H.B.
V.T.R.
FLOOR DRAIN
DOWN
VENT THRU ROOF
HOSE BIBB
SCREWED & FLANGED
CHECK VALVE
GATE VALVE
PIPE TEST PLUG
FLEX. PIPE CONN.
CONCENTRIC REDUCER
HP HOT WATER REC. PUMP
RD ROOF DRAIN
ARRESTOR "SIZE"
EWH ELECTRIC WATER HEATER
B.F. BELOW FLOOR
HOT WATER RETURN
TP TRAP PRIMER
HOT WATERHW (60°C)60°C
WALL HYDRANT
FM FIRE MAIN
MANUAL AIR VENT
PUMP
CALIBRATED BALANCING
VALVE
FF FINISHED FLOOR
AFF ABOVIE FINISHED FLOOR
IWFT
INDIRECT FUNNEL AND
WASTE TRAP
W.C.O. WALL CLEANOUT
BOP BOTTON OF PIPE
C CENTER LINE
TOP TOP OF PIPE
L
US Army Corps of Engineers ®
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K E
D B
Y:
AN
SI
D
FI
LE
N
A M E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
M O
BI
LE
, A L
P001
UN
AC
CO
M
PA
NI
ED
E
NL
IS
TE
D
PE
R S
O
NN
EL
H
O
US
IN
G
M O
BI
LE
D
IS
TR
IC
T R
. P
ER
SO
N
EN
-D
E
W . K
N
AP
P
B.
D
U R
H
AM
FE
BR
U
AR
Y
W
9R
M
7E U
M
7E U
SO
TO
C A N
O A
IR
B
AS
E, H O
ND
UR
AS
PL
UM
BI
NG
N O
TE
S, L
EG
EN
D , A
ND
S
CH
E D
UL
E
M
AR
K D
AT
E
AM
EN
D
.0
/2
9/
R
EV
IS
ED
S C
H
ED
U
LE
A N
D N
O
TE
S.
W
W W
W W
W W
W W
W W
W W
W W
1 2 3 4 5 6 7 8 9
A
B
C
D
1 2 3 4 5 6 7 8 9
B
C
D
PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1
PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1
EF-1 EF-1 EF-1
EF-1
(TYP.) EF-1 EF-1
EF-1EF-1EF-1
EF-1
EF-1EF-1
PTAC-1
AHU-1
DORM
157ELEC
LAUNDRY
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
200 MM WALL CAP
W/ B.D.D. (TYP.)
FC-1
FC-2
CU-1 CU-2 CU-3
CU-4 CU-5 CU-6 CU-8 CU-9
EF-2
EF-3
200x100 24 L/s
76ø 76ø 76ø
76ø76ø 76ø
76ø
76ø
76ø
76ø
76ø
76ø
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s 200x100
24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
203x102
200x100 24 L/s
203x102
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
457x457
DRYER EXH.
DUCT(4-TYP)
PTAC CONDENSATE DRAIN
DN TO DRYWELL (TYP.)
203x305 305x305
305x305
305x305 305x305 203x305 203x305
CU-7
254ø 254 EA UP TO
2ND FLR EA LVR
PLENUM
102ø
102 EA UP TO
2ND FLR
355x355 236 L/s
1 2 3 4 5 6 7 8 9
A
B
C
D
1 2 3 4 5 6 7 8 9
A
B
C
D
PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1
PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1
EF-1
EF-1 EF-1 EF-1 EF-1 EF-1
EF-1EF-1EF-1EF-1EF-1EF-1
PTAC-1
AHU-2
200 MM WALL CAP
W/ B.D.D. (TYP.)
FC-1
FC-2
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
LAUNDRY
ELEC
MECH
219 ACTIVITY
DAYROOM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
EF-2
EF-3
457x457
DRYER EXH.
DUCT(4-TYP)
PTAC CONDENSATE DRAIN
DN TO DRYWELL (TYP.)
203x305 203x305
305x305
305x305 305x305 305x305 203x305 203x305
76ø
76ø76ø76ø
76ø 76ø
76ø
76ø
76ø 76ø
76ø 76ø
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s200x100
24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
NONVENTED LOUVER
SEE ARCHITECTURE
FOR DETAILS
610x914 E.A.
LOUVER
W/ B.S.
254ø
254ø
127ø
102ø
355x355 236 L/s
GENERAL SHEET NOTES:
SEE SHEET M-001 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.1.
PLAN NORTH IS FOR REFERENCE ONLY AND IS BASED ON BUILDING D. SEE CIVIL
FOR BUILDING ORIENTATION.
2. US Army Corps of Engineers ®
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K E
D B
Y:
AN
SI
D
FI
LE
N
A M E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
M O
BI
LE
, A L
M101
UN
AC
CO
M
PA
NI
ED
E
NL
IS
TE
D
PE
R S
O
NN
EL
H
O
US
IN
G
M O
BI
LE
D
IS
TR
IC
T R
. P
ER
SO
N
R . P
ER
SO
N
W . K
N
AP
P
B.
D
U R
H
AM
FE
BR
U
AR
Y
W
9R
M
7E U
M
7E U
SO
TO
C A N
O A
IR
B
AS
E, H O
ND
UR
AS
HV
A C
F
LO
O R
P L
AN
1 : 1001 HVAC PLAN 1ST FLOOR
1 : 1002 HVAC PLAN 2ND FLOOR
PLAN NORTH
SCALE:
0 80004000
1 : 100NOTE: ALL UNITS ARE IN MILLIMETERS
UNLESS INDICATED OTHERWISE.
M
AR
K D
AT
E
AM
EN
D
.0
/2
9/
C
LA
R
IF
IE
D
M
EC
H
J
AN
IT
O
R E
XH
, L
AU
N
D S
U
PP
W W
W W
W W
1 2 3 4 5 6 7 8 9
A
B
C
D
1 2 3 4 5 6 7 8 9
A
B
C
D
PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1
PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1
EF-1 EF-1 EF-1 EF-1 EF-1 EF-1
EF-1EF-1EF-1
EF-1
EF-1
EF-1
PTAC-1
1270x1270
O.A. INTAKE
LOUVER W/ B.S.
200 MM WALL CAP
W/ B.D.D. (TYP.)
FC-1
FC-2
AHU-2
DORM
DORM
DORM
DORM
DORM
DORM
MECH
ACTIVITY
DORM
DORM
DAYROOM
LAUNDRY
ELEC
DORM
DORM
376DORM
DORM
DORM
DORM
DORM
DORM
DORM
DORM
348DORM
EF-2
EF-3
DORM
DORM
DORM
DORM
457x457
305x305305x305
457x305 203x305
DORM
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
200x100 24 L/s
76ø 76ø 76ø
76ø76ø76ø
76ø 76ø 76ø
76ø
76ø 76ø102ø
DRYER EXH.
DUCT(4-TYP)
PTAC CONDENSATE DRAIN
DN TO DRYWELL (TYP.)
203x305203x305 305x305 203x305
254ø
254 EA DN TO
2ND FLR EA LVR
PLENUM
102ø
102 EA DN TO
2ND FLR EA LVR
PLENUM
355x355 236 L/s
GENERAL SHEET NOTES:
SEE SHEET M-001 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.1.
PLAN NORTH IS FOR REFERENCE ONLY AND IS BASED ON BUILDING D. SEE CIVIL
FOR BUILDING ORIENTATION.
2.
EF-4
T
US Army Corps of Engineers ®
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K E
D B
Y:
AN
SI
D
FI
LE
N
A M E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
M O
BI
LE
, A L
M102
UN
AC
CO
M
PA
NI
ED
E
NL
IS
TE
D
PE
R S
O
NN
EL
H
O
US
IN
G
M O
BI
LE
D
IS
TR
IC
T R
. P
ER
SO
N
EN
-D
E
W . K
N
AP
P
B.
D
U R
H
AM
FE
BR
U
AR
Y
W
9R
M
7E U
M
7E U
SO
TO
C A N
O A
IR
B
AS
E, H O
ND
UR
AS
HV
A C
F
LO
O R
P L
AN
1 : 1001 HVAC PLAN 3RD FLOOR
PLAN NORTH
SCALE:
0 80004000
1 : 100
M
AR
K D
AT
E
AM
EN
D
.0
/2
9/
1 : 1002 HVAC PLAN PUMP BLDG
**NOTE: SEE CIVIL FOR BLDG SITE LOCATION.
C
LA
R
IF
IE
D
M
EC
H
J
AN
IT
O
R E
XH
, L
AU
N
D S
U
PP
A B C DA B C D
457x457
457x457
457x457
457x457
457x457
457x457
457x457
AHU-3
AHU-2
AHU-1
1270x1270
O.A. INTAKE
LOUVER W/ B.S.
305x305 S.A.
ABV CEILING
(TYP)
SOLAR WATER EATING
PANELS (TYPICAL OF BLDG'S
E & F. SEE PLUMBING )
SOLAR WATER HEATING
PANELS (TYPICAL OF
BLDG D)
4- DRYER VENTS
(3-TYPICAL)
102ø
102ø 102ø
102ø
102ø
102ø 102ø
102ø
102ø
102ø 102ø
102ø
305x457
305x457
305x457
GENERAL SHEET NOTES:
SEE SHEET M-001 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.1.
PLAN NORTH IS FOR REFERENCE ONLY AND IS BASED ON BUILDING D. SEE CIVIL
FOR BUILDING ORIENTATION.
2.
A BA B
610x914 E.A.
LOUVER W/ B.S.
&PLENUM BEHIND
254ø
254ø
254ø
305ø
254ø
254ø
127ø
127ø
127ø
102ø
EF-2
EF-2
EF-2
E.A. DUCT FROM
JANITOR EF-3
E.A. DUCT FROM
JANITOR EF-3
E.A. DUCT FROM
JANITOR EF-3
US Army Corps of Engineers ®
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K E
D B
Y:
AN
SI
D
FI
LE
N
A M E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
M O
BI
LE
, A L
M301
UN
AC
CO
M
PA
NI
ED
E
NL
IS
TE
D
PE
R S
O
NN
EL
H
O
US
IN
G
M O
BI
LE
D
IS
TR
IC
T R
. P
ER
SO
N
EN
-D
E
W . K
N
AP
P
B.
D
U R
H
AM
FE
BR
U
AR
Y
W
9R
M
7E U
SO
TO
C A N
O A
IR
B
AS
E, H O
ND
UR
AS
HV
AC
B
UI
LD
IN
G S
E C
TI
O N
M
AR
K D
AT
E
AM
EN
D
.0
/2
9/
1 : 501 MECHANICAL BLDG CROSS SECTION
1 : 502 MECHANICAL AND JANITOR RMS EXHAUST SECTION
C
LA
R
IF
IE
D
M
EC
H R
M
J
AN
IT
O
R E
XH
AU
ST
UNIT CU-1, 2, & 3 SHALL BE PROVIDED WITH LEAD DIGITAL SCROLL COMPRESSOR.
AIR COOLED
CU-2
ELECTRICAL
STEPS OF REDUCTION/COMPRESSOR
LOW AMBIENT TEMP.- °C (°F)
DESIGN AMBIENT EMP.- °C (°F)
NO. OF COMPRESSORS
REMARKS:
DATA
HERTZ
MAX. UNIT KW.
VOLTS
PHASE
CAPACITY KW (MBH)
MARK
TYPE
ASSOCIATED FAN COIL
UNITARY CONDENSING UNIT SCHEDULE
AIR COOLED
CU-3CU-1
AIR COOLED
35(120)
AHU-1
1.
ALL CONDENSING UNITS SHALL BE PROVIDED WITH SATURATED SUNCTION TEMPERATURE OF2.
5.55 DEG C.
UNIT CU-1, 2, & 3 SHALL BE PROVIDED WITH DUAL REFRIGERANT CIRCUITS3.
1.7 (35)
35 (95)
2.6 (9)
AIR COOLED
CU-5
FC-1
CU-4
AIR COOLED
35(120)
AHU-2
35(120)
AHU-3
1.7 (35)
35 (95)
2.6 (9)
FC-2
1.7 (35)
35 (95)
2.6 (9)
AIR COOLED
CU-7
FC-1
CU-6
AIR COOLED
1.7 (35)
35 (95)
2.6 (9)
FC-2
1.7 (35)
35 (95)
2.6 (9)
AIR COOLED
CU-9
FC-1
CU-8
AIR COOLED
1.7 (35)
35 (95)
2.6 (9)
FC-2
DATA
FILTER
DATA
ELECTRICAL
DATA
COIL
COOLING
DATA
FAN
NO. OF ROWS
MAXIMUM FINS/CM
MAX. OUTLET VEL.-M.P.M.
FAN TYPE
MINIMUM OUTSIDE AIR-LPS
LVG. DB/LVG. WB - C
ENT. DB/ENT. WB - C
HERTZ
PHASE
VOLTS
MOTOR KW
MARK
TYPE
LOCATION
MAXIMUM FAN R.P.M.
EXT. S.P.- PA.
CAPACITY (KW
MIN. SAT. SUC. TEMP.-C
MAX. FACE VEL.-M.P.M.
SUPPLY AIR-LPS
TYPE
MAX. FACE VEL.-F.P.M.
INITIAL P.D.- PA
FINAL P.D.- PA
REMARKS:
MAX. AIR P.D.- PA.
AHU-1
DRAW THRU
MECH RM
F.C.
27.2/26.11
12.22/12.22 152.8 5.55
.75
MERV 13
1. PROVIDE WITH VARIABLE FREQUENCY DRIVE AND
PREMIUM EFFICIENCY MOTOR RATED FOR INVERTER DUTY.
2. FAN SHALL BE SELECTED BASED ON DIRTY FILTER
CONDITIONS.
3. PROVIDE WITH STAINLESS STEEL COIL HEADERS.
4. PROVIDE STAINLESS STEEL DRAIN PAN.
AIR HANDLING UNIT SCHEDULE
5. AIR HANDLING UNITS CASING SHALL BE DOUBLE WALLED.
6. AIR HANDLING UNITS SHALL BE PROVIDED WITH DUAL FULL-FACED
REFRIGERANT CIRCUITS.
F.C. = FORWARD CURVED
AHU-2
DRAW THRU
MECH RM
F.C.
27.2/26.11
12.22/12.22 152.8 5.55
.75
MERV 13
AHU-3
DRAW THRU
MECH RM
F.C.
27.2/26.11
12.22/12.22 152.8 5.55
.75
MERV 13
DATA
HEATING
STEPS
KW 7.5
.7.5
7.5
L/S (CFM) (HIGH SPEED)
INPUT WATTS @ ARI COND.
ELECTRICAL
REMARKS:
DATA
COOLING
DATA
60HERTZ
PHASE
VOLTS
TOTAL CAP. KW (MBH)
SENS. CAP. KW (MBH)
DESIGN AMB. TEMP.-°C (°F)
TYPE
MARK
35 (95)
2.5 (8.5)
2.6 (9)
113 (240)
WALL MTD
FC-1
UNITARY FAN COIL UNIT SCHEDULE
35 (95)
2.5 (8.5)
2.6 (9)
113 (240)
WALL MTD
FC-2
OUTSIDE AIR - LPS
DATA
HEATING
DATA
ELECTRICAL
DATA
COOLING
INDOOR FAN - LPS
ENT. DB/ENT. WB - C
NO. OF STEPS
HEATER SIZE - KW
HERTZ
PHASE
VOLTS
KW INPUT
MARK
TYPE
TOTAL CAPACITY (KW)
MIN. UNIT EER
AMBIENT TEMP. - C
NOTES: UNIT HAS TWO-SPEED FAN.
AIR CONDITIONER SCHEDULE
PACKAGED TERMINAL
PTAC-1
THRU WALL
2.64
24/17
N.A.
.5
REFRIGERANT SHALL BE R-410a.
ELECTRICAL
EXTERNAL S.P.- PA.
REMARKS:
DATA PHASE
VOLTS
MOTOR - WATTS
HERTZ
DRIVE TYPE
M…