Questions and Answers for MS2085A Analyzer-2.pdf

PDF 73 KB Posted

Attached to
MS2085A Analyzer
Solicitation number
W9124B27QA001
Issued by

About this file

This is a Questions and Answers document for a federal contract opportunity regarding the MS2085A Analyzer.

The Government seeks delivery of an MS2085A Analyzer with specific configurations and requirements. The delivery deadline is on or before 01 February 2027. The quote submission deadline is 08 December 2026 at noon Pacific time, to be submitted via PIEE (or by email with proof of browser failure). The acquisition is a Total Small Business Set-Aside. The required configuration includes Option 804, Option 21 (2-port transmission), and premium calibration; Option 15 (Vector Voltmeter) is not required. Regarding the frequency range option, the document references "revised salient characteristics" for the specific frequency requirement (Option 904 at 4 GHz or Option 906 at 6 GHz). The unit weight specification has been updated in the revised salient characteristics to accommodate manufacturer specifications when configured with required options. FAR 52.219-33 does not apply and will be removed via amendment.

For the delivered analyzer, IUID marking and reporting requirements apply because the unit acquisition cost for CLIN 0001 is $5,000 or more under DFARS 252.211-7003. The delivered end item must bear a permanent 2D Data Matrix ECC 200 symbol with human-readable text per MIL-STD-130N (with Change 1). Supplier-applied compliant marking is acceptable when applied by a reseller or third-party vendor, provided the label meets durability and verification standards, does not obscure OEM labels, and exactly matches the UII data submitted in WAWF. The contractor must submit UII and required IUID data elements electronically via Wide Area Workflow in PIEE upon shipment/invoicing for registration in the DoD IUID Registry. PIEE remains the required submission method for all contractual communications.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions and Answers for MS2085A Analyzer

Question #1: Section F lists delivery on or before 30 Nov 2026, which is also the quote due date. Will the Government accept a delivery date stated as a number of days after award, and if so, is there a latest acceptable date?

Answer #1: Delivery date will be on or before 01 February 2027.

Question #2: The salient characteristics call for a weight under 7 lb and also name Options 21, 15 and 904/906. Anritsu's data sheet lists the MS2085A at 3.1 kg (6.83 lb) without Option 21 and 3.8 kg (8.39 lb) with it, and Options 15, 904 and 906 each require Option 21.

Will the Government accept that configuration at the manufacturer's published weight?

Answer #2 Please see updated salient characteristics

Question #3: SF-1449 Block 8 shows 09 Nov 2026, the SAM notice text says November 30, 2027, and the PIEE notice shows 30 Nov 2026 at 12:00 PM PST. Can you confirm quotes are due 30 Nov 2026 at 12:00 PM PST through the PIEE link?

Answer #3 Due date for quotes will be extended to 08 December 2026 due to an amendment.

Question #4 Per Anritsu: without including the optional standard, premium or accredited calibration package with this unit it will ship with a "basic cert". If the unit in question for the training division at Fort Irwin requires a formal calibration certificate the standard calibration will be needed at a minimum.

Can you advise if we need to quote this model to be inclusive of a calibration certificate or if the basic certificate will cover their needs?

Answer #4 , we need the premium calibration, the standard one will not pass at our local CAL. lab.

Question #5 Please confirm the required configuration: frequency range option (904, 4 GHz, or 906, 6 GHz), and whether Option 15 (Vector Voltmeter) and Option 21 (2-port transmission) are both required.

Frequency option. Does the Government require the 6 GHz model (Option 906), or is the 4 GHz model (Option 904) acceptable?

Options 21 and 15. The purchase description lists 2-port transmission (Option 21) and vector voltmeter (Option 15) under supported measurements. Should quotes include both options?

Answer #5 Please see revised salient characteristics.

Questions #6 The amended SF1449, SF30 and Q&A state December 8, 2026, while the SAM header shows December 8, 2027. Please confirm the controlling deadline is December 8, 2026, at noon Pacific, and that the posted files marked DRAFT constitute the issued amendment. Please confirm the revised salient characteristics supersede the original, including Option 804, Option 21, premium calibration, listed kit/cable, and no Option 15.

Answer #6 Please refer to the Q&A for deadline date (answer #3). Please refer to the revised salient characteristics.

Question #7 The amendment includes FAR 52.219-33, with evaluation language saying “if applicable.” Is the acquisition at or below the applicable simplified acquisition threshold, so the rule does not apply to this Total Small Business Set-Aside? If it does apply, please identify any applicable SBA class or individual waiver and the required manufacturer evidence. Please confirm the applicable DFARS origin representation for a reseller-supplied Anritsu package.

Answer #7 FAR 52.219-33 does not apply and will be removed via amendment.

Question #8 Please confirm whether PIEE remains the required submission method and whether any additional controlling files are posted only there. This browser could not open the linked PIEE page.

Answer #8 PIEE is the required submission method. Try using another browser to open the link. If using another browser still doesn’t work, you can submit via email.

However, you must show proof that the browser doesn’t work by submitting screenshots.

Question #9 Please also confirm the IUID marking/reporting required for CLIN 0001 and whether supplier-applied compliant marking is acceptable.

Answer #9 IUID Marking Requirement (CLIN 0001): Because the unit acquisition cost for CLIN 0001 is $5,000 or more, DFARS 252.211-7003 (Item.Unique.Identification.and.

Valuation) applies . The delivered end item must be marked with a permanent 2D Data Matrix ECC 200 symbol (with human-readable text) in accordance with MIL-STD-130 (MIL-STD-130N w/ Change 1), meeting the standard's syntax (ISO/IEC 15434), permanence, and verification grading requirements .

IUID Reporting Requirement: Pursuant to DFARS 252.211-7003, the Contractor must submit the Unique Item Identifier (UII) and required IUID data elements electronically via Wide Area Workflow (WAWF) in PIEE upon shipment/invoicing for registration in the DoD IUID Registry .

Supplier-Applied Marking: Yes, supplier-applied compliant marking is acceptable.

Under DFARS 252.211-7003, the prime contractor is responsible for ensuring the item is properly marked and registered . A reseller or its third-party vendor may apply a MIL- STD-130-compliant UID label (using the supplier's Enterprise Identifier/CAGE code and the item's serial number under Construct 1 or Construct 2), provided the label meets MIL-STD-130 durability and verification standards, does not obscure OEM serial/calibration labels, and exactly matches the UII data submitted in WAWF .

File details come from the government source that posted it. Updated .