The Government has clarified several key requirements through this Q&A document. The delivery date has been extended to on or before 01 February 2027, and the quote due date has been extended to 08 December 2026. Regarding product specifications, the Government will accept the MS2085A configuration at the manufacturer's published weight (3.8 kg/8.39 lb with Option 21), despite exceeding the initially stated 7 lb requirement. For calibration, the Government requires premium calibration; standard calibration will not meet their local CAL lab standards. The specific configuration requirements regarding frequency range options (904 at 4 GHz versus 906 at 6 GHz) and whether Options 15 (Vector Voltmeter) and 21 (2-port transmission) are both required have been deferred to revised salient characteristics, which are referenced but not provided in this document. Prospective offerors should consult the updated salient characteristics document to confirm the exact configuration specifications for their quotes.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions and Answers for MS2085A Analyzer
Question #1: Section F lists delivery on or before 30 Nov 2026, which is also the quote due date. Will the Government accept a delivery date stated as a number of days after award, and if so, is there a latest acceptable date?
Answer #1: Delivery date will be on or before 01 February 2027.
Question #2: The salient characteristics call for a weight under 7 lb and also name Options 21, 15 and 904/906. Anritsu's data sheet lists the MS2085A at 3.1 kg (6.83 lb) without Option 21 and 3.8 kg (8.39 lb) with it, and Options 15, 904 and 906 each require Option 21.
Will the Government accept that configuration at the manufacturer's published weight?
Answer #2 Please see updated salient characteristics
Question #3: SF-1449 Block 8 shows 09 Nov 2026, the SAM notice text says November 30, 2027, and the PIEE notice shows 30 Nov 2026 at 12:00 PM PST. Can you confirm quotes are due 30 Nov 2026 at 12:00 PM PST through the PIEE link?
Answer #3 Due date for quotes will be extended to 08 December 2026 due to an amendment.
Question #4 Per Anritsu: without including the optional standard, premium or accredited calibration package with this unit it will ship with a "basic cert". If the unit in question for the training division at Fort Irwin requires a formal calibration certificate the standard calibration will be needed at a minimum.
Can you advise if we need to quote this model to be inclusive of a calibration certificate or if the basic certificate will cover their needs?
Answer #4 , we need the premium calibration, the standard one will not pass at our local CAL. lab.
Question #5 Please confirm the required configuration: frequency range option (904, 4 GHz, or 906, 6 GHz), and whether Option 15 (Vector Voltmeter) and Option 21 (2-port transmission) are both required.
Frequency option. Does the Government require the 6 GHz model (Option 906), or is the 4 GHz model (Option 904) acceptable?
Options 21 and 15. The purchase description lists 2-port transmission (Option 21) and vector voltmeter (Option 15) under supported measurements. Should quotes include both options?
Answer #5 Please see revised salient characteristics.