2.8 Sanitary Sewer Cleanout_202501060949384694.pdf

PDF 320 KB Posted

Attached to
Sanitary Capacity
Solicitation number
W9124926RA015
Issued by

About this file

This is a technical specification detail drawing for a sanitary sewer cleanout installation issued by the Augusta Utilities Department. The document provides construction standards for a single service main connection that includes a 6-inch PVC cleanout with a twist-off plug, a precast concrete valve ring with 5/8-inch rebar reinforcement, and connection to the sewer main via 6-inch T-WYE fittings. The cleanout is positioned at the right-of-way with a minimum slope of 1/8 inch per foot toward the sewer main and must include a 12-gauge copper tracer wire attached to the pipe for utility locating purposes, with the tracer wire remaining accessible at grade level.

Key construction requirements specify that no bends are permitted between the sewer cleanout and sewer tap, pipe materials for the cleanout and mainline must be identical, and a street-rated sewer cleanout cap is required when located in pavement. The builder's plumber may optionally cut into the standpipe to install a 6-inch WYE to minimize connection depth, with the builder assuming all responsibility for any resulting damage to the sewer service or tap, which must be repaired according to Richmond County Specifications. The detail was revised in November 2024 and approved January 2025 by the Augusta Utilities Department, located at 452 Walker Street, Suite 200, Augusta, Georgia 30901. No revisions or modifications may be made without prior written approval from the Augusta Utilities Department.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASPHALT

CURB

6"PVC 4"

FROM

BLDG.

6" P

V C

R

IG

H T-

O F-

W A

Y

12"

BY UTILITY

CONTRACTOR

BY PLUMBING

CONTRACTOR

6" PVC

SEWER

MAIN

SANITARY SEWER CLEANOUT

AUD DETAIL 2.8

TO SEWER MAIN

MIN SLOPE 1/8" PER

FT OR 1%

PRECAST CONCRETE

VALVE RING WITH 5/8"

REBAR ALONG SIDE

6" CLEANOUT WITH PVC

TWIST-OFF PLUG

PLUG HERE FOR END OF LINE

UNTIL PLUMBER MAKES

CONNECTION

12 GAUGE COPPER TRACER WIRE ATTACHED

TO PIPE

6" T-WYE

6" T-WYE

ATTACH TRACER WIRE

NO REVISION OR MODIFICATION OF THIS DETAIL SHALL BE MADE WITHOUT

PRIOR WRITTEN APPROVAL FROM AUGUSTA UTILITIES DEPARTMENT.

NOTE:

1. STREET RATED SEWER CLEANOUT CAP REQUIRED WHEN LOCATED IN

PAVEMENT.

2. THERE WILL BE NO BENDS BETWEEN THE SEWER CLEAN-OUT AND THE

SEWER TAP.

3. SEE DETAIL 2.2

4. THE BUILDER'S PLUMBER HAS THE OPTION TO CUT INTO THE STAND PIPE AND

INSTALL A 6" WYE AS SHOWN TO MINIMIZE THE DEPTH OF CONNECTION. ANY

DAMAGE TO THE SEWER SERVICE OR TAP SHALL BE THE BUILDER'S

RESPONSIBILITY TO REPAIR. ALL REPAIRS OR REPLACEMENT SHALL BE IN

ACCORDANCE WITH RICHMOND COUNTY SPECIFICATIONS.

5. PIPE MATERIALS FOR CLEANOUT AND MAINLINE MUST BE THE SAME.

6. CUT & CAP OF EXISTING SERVICE CAP CUSTOMER SIDE AND SET CLEAN-OUT

AT RIGHT-OF-WAY.

7. THIS IS A SINGLE SERVICE MAIN.

AUGUSTA UTILITIES DEPARTMENT

452 WALKER STREET, SUITE 200

AUGUSTA, GA 30901

CONTRACTOR TO ENSURE TRACER

WIRE IS ACCESSIBLE AT GRADE FOR

UTILITY LOCATING PURPOSES.

REVISED: NOV. 2024

APPROVED JAN. 2025

STONE BEDDING

SEE NOTE #3

6" PVC

4"PVC

OPTIONAL PRIVATE

SEWER SERVICE

LINE CONNECTION;

MINIMUM DEPTH

PER PLUMBING

CODE. SEE NOTE #4