Section_J_Location_Specifications.xlsx
XLSX spreadsheet 15 KB Posted
- Attached to
- DoDEA Preventative Maintenance & Repair (Campbell/Knox) Federal contract opportunity
- Solicitation number
- W9123619R0022
About this file
Section J Location Specs
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A.07.24_Amendment_4_W912DS19R0022.pdf | ||
| A.07.24_Amendment_3_W912DS19R0022.pdf | ||
| A.07.24_Amendment_2_W912DS19R0022.pdf | ||
| Revised_Bid_Schedule.xlsx | XLSX spreadsheet | |
| A.07.24_Amendment_1_W912DS19R0022.pdf | ||
| A.07.23_Solicitation_W912DS19R0022.pdf | ||
| Price_Proposal_Worksheet_(Bid_Schedule).xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Campbell
| DoDEA Americas Ft CAMPBELL FACILITIES | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
| FACILITY NAME: |
Author: Author:
| Insert School or Facility Name (e.g. schools, maint BLD, DSO, etc) | Barkley ES (New) | Barsanti ES | Fort Campbell HS (Old) | Fort Campbell HS (New) | Jackson ES | Lucas ES | Mahaffey MS | Marshall ES (NEW) | CSO Admin | CSO Bus Barn | CSO Maintenance |
| INSTALLATION: |
Author: Author:
| Installation Name | Fort Campbell | Fort Campbell | Fort Campbell | Fort Campbell | Fort Campbell | Fort Campbell | Fort Campbell | Fort Campbell | Fort Campbell | Fort Campbell | Fort Campbell |
| LOCATION: |
Author: Author:
| Facility Address and/or building # | 177 Gorgas Avenue | |||||||||||
| Fort Campbell, KY 42223 | BLD 7409 Fort Campbell, TN 42223 | BLDs 902/903/904/905/916 Bastogne Ave | ||||||||||
| Fort Campbell, TN 42223 | Fort Campbell, TN 42223 | BLDs 710/711/712 Mississippi Ave, Fort Campbell, TN 42223 | 2115 Indiana Fort Campbell, TN 42223 | BLDs 71/73 South Carolina Avenue, Fort Campbell, TN 42223 | 70 Texas Ave | |||||||
| Ft Campbell, KY 42223 | BLDs 78/85/84/86 Texas Avenue, Fort Campbell, TN 42223 | BLDs 5440/5441 Airborne Street, Fort Campbell, TN 42223 | BLDs 1110/1112 Falcon Loop, Fort Campbell, TN 42223 | |||||||||
| COUNTY: | Christian County | Montgomery County | Montgomery County | Montgomery County | Montgomery County | Montgomery County | Montgomery County | Christian County | Montgomery County | Montgomery County | Montgomery County | |
| FACILITY USE: |
Author: Author:
| Indicated grades of students at school and/or any other major facility uses (e.g. VocEd, IT Hub, etc) | PK-5 | PK-5 | Grades 9-12/Maint | Grades 9-12 | PK-5/Maint | PK-5 | Grades 6-8/Maint | PK-5 | Admin/IT/Storage/Maint | Maint/Fuel | Storage/Maint |
| GROSS SQUARE FOOTAGE: |
Author: Author:
| GSF of permanent structure | 142049 | 89179 | 104,663/951/1,136/1,206/4,875 | 184,232 | 81,311/1,224/1,224 | 86,603 | 73,004/1,238 | 112,000 | 3,623/1,224/11,402/4,811 | 4,291/200 | 8,225/5,368 |
| KITCHEN/CAFETERIA? |
Author: Author:
| Indicate whether the facility has a kitchen | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | No | No | No |
| MULTIPURPOSE ROOM/AUDITORIUM? |
Author: Author:
| Indicate whether the facility has a multipurpose room | Yes | No | Yes | Yes | Yes | Yes | Yes | Yes | No | No | No |
| GYMNASIUM? |
Author: Author:
| Indicate whether the facility has a gym | Yes | No | Yes | Yes | Yes | Yes | No | Yes | No | No | No |
| MAJOR MECHANICAL SYSTEMS: |
Author: Author:
| Indicate the major HVAC system type (e.g. rooftop units with gas-fired heating, constant vs variable volume, split system Acs, air handlers with hydronic heating and cooling, chiller plants, boilers, etc) | Ground Source Heat Pumps, Mini Splits | RTUs DX Cooling/Gas Heat, Mini Splits | OAUs Gas Heat/Chilled Water, Air Cooled Chillers, RTUs DX Cooling/Gas Heat, FCUs Chilled Water/Elect Heat/Split System Heat Pumps | GSHP, OAUs, Air Cooled Chillers | Water Source Heat Pumps, Boilers, Cooling Towers, Package Units | Water Source AHUs, Boilers/Air Cooled Chillers, RTUs DX Cooling/Gas Heat | RTUs DX Cooling/Gas Heat | Water Source Heat Pumps, Boilers/Cooling Towers, Mini Splits, OAUs DX Heating/Cooling | Gas Package Unit, Split System Heat Pump, PTAC, Unit Heaters | Split System Heat Pumps, Gas Unit Heaters | Split System Heat Pump, Gas Radiant Tube Heaters |
| PRIMARY TYPE OF CONSTRUCTION: |
Author: Author:
| Indicate the primary type of construction of the building (CMU exterior, wood structure, metal roof, EPDM, modified bitumen roof, sloped, flat, | Steel Frame, Reinforced ICF w/ brick veneer and concrete panel cladding | Brick Veneer | Brick veneer, Painted Concrete/ Wood framing & metal siding/steel & metal siding/painted concrete/steel & stucco | Steel Frame, reinforced CMU, ICF, brick veneer, metal panels, aluminum window systems | CMU, Brick Veneer, Aluminum Window Systems/steel & metal siding | CMU, Steel, Brick Veneer, Stucco | CMU, Brick Veneer/steel & metal siding | Structural Steel, CMU, Brick Veneer, Metal Cladding | Structural Steel & Metal Siding/ CMU, Brick Veneer, Aluminum Window Systems | Structual Steel, Metal Siding, Interior Wood Framing | Structual Steel, Metal Siding, Interior Wood Framing |
| YEAR OF CONSTRUCTION: |
Author: Author:
| Indicate the year of constuction of the building, plus any additions, or renovations. | 2016 | 2011 | 1985/1982/1987/1986/2008 | Complete August 2017 | 1958/1984/1984 | 1997 | 1967/1988 | 2016 | 2012/1982/1961/1986 | 1990/1991 | 1992/2010 | |
| MAINTENANCE SECTIONS | ||||||||||||
| Section C-3 (Mech) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
| Section C-4 (DDC) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
| Section C-5 (Plumbing) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
| Section C-6 (Electrical) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
| Section C-7 (Kitchen Equipment) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
| Section C-8 (Roof Systems & Site) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
| Section C-9 (Building Systems) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
| Section C-10 (Fire Alarm & Suppression) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
| Section C-11 (Playgrounds) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
File details come from the government source that posted it.