This solicitation package seeks proposals for roof repairs to three buildings at White Sands Missile Range in New Mexico. The contractor will be responsible for re-roofing buildings 1362, 1530, and 1644, furnishing all labor, materials, equipment, tools, transportation, bonds and other supplies needed to complete the work. The procurement will be set aside exclusively for Historically Underutilized Business Zone small businesses. The contract type will be firm-fixed-price with a period of performance of 200 calendar days. The NAICS code is 238160 and the estimated value is between $1,000,000 to $5,000,000. Interested offerors should review the attached solicitation and supporting documents for additional requirement details.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Appendix B
ROOFER Data
Supplied roofing data is from an assessment performed in 2011. Some information may have changed since the assessment.
Metal roof data is extremely limited.
Roof Penetration Legend:
Equipment Riser/Curb
Pitch Pan
Equipment Riser/Curb
Pipe, Typically Vent
D I S T R E S S
S E V E R I T Y
D E F E C T
Q U A N T I T Y
N U M B E R
Building:
Section:
01644 - HISTORIC CALIBRATION BLDG
A
Perimeter Flashing:
Curb Flashing:
696 (LF)
184 (LF)Inspection Date: 1/31/2011
Roof Type: Built-Up
Key Plan
Thru Panel Fasteners:
Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP)
Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV)
Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD)
Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)
1 EM L 1 487
2 EM M 1 48
3 PP L 1 12
4 DV M 1 50
5 PP H 4 12
6 EQ L 1 12
7 SR M 1 10
8 EQ H 2 2
Roof Section Inspection Worksheet History
White Sands Missile Range (35995) Unassigned
Page 1 of 4September 09, 2020
S T R E S S
S E V E R I T Y
D E F E C T
Q U A N T I T Y
N U M B E R
Building:
Section:
01644 - HISTORIC CALIBRATION BLDG
B
Perimeter Flashing:
Curb Flashing:
312 (LF)
0 (LF)Inspection Date: 1/29/2011
Roof Type: Built-Up
Key Plan
Thru Panel Fasteners:
Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP)
Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV)
Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD)
Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)
1 EM L 1 312
2 EM M 1 31
3 SR H 1 28
4 PP L 1 2
5 PP H 4 1
6 DV M 1 2
7 SR M 1 350
Roof Section Inspection Worksheet History
Page 2 of 4September 09, 2020
S T R E S S
S E V E R I T Y
D E F E C T
Q U A N T I T Y
N U M B E R
Building:
Section:
01644 - HISTORIC CALIBRATION BLDG
C
Perimeter Flashing:
Curb Flashing:
44 (LF)
0 (LF)Inspection Date: 1/29/2011
Roof Type: Built-Up
Key Plan
Thru Panel Fasteners:
Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP)
Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV)
Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD)
Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)
1 EM L 1 30
2 EM M 1 3
Roof Section Inspection Worksheet History
Page 3 of 4September 09, 2020
S T R E S S
S E V E R I T Y
D E F E C T
Q U A N T I T Y
N U M B E R
Building:
Section:
01644 - HISTORIC CALIBRATION BLDG
D
Perimeter Flashing:
Curb Flashing:
29 (LF)
0 (LF)Inspection Date: 1/29/2011
Roof Type: Built-Up
Key Plan
Thru Panel Fasteners:
Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP)
Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV)
Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD)
Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)
1 EM L 1 20
2 EM M 1 2
Roof Section Inspection Worksheet History
Page 4 of 4September 09, 2020
Building:
Last Replacement:Occupancy:
01644 - HISTORIC CALIBRATION BLDG
4/21/2000
Sec Name:
Original Construction: 1/1/1959Area:
A
15,026 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
0 (LF) 487 (LF)
0 (LF) 0 (LF)
210 (LF)
0 (LF)
Access: EXTERNAL LADDER: Permanent
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Bar Joists/Combination
STEEL
1/8 in 12
GUTTERS & DOWNSPOUTS
NONE
Structure:
Roof Category: Membrane
ROOF EDGE: Embedded Edge Metal, PITCH PAN, EQUIPMENT SUPPORT: Curbs, PLUMBING VENT, ROOF
PENETRATION, WALL/PARAPET
AGG: Crushed Stone
Description:
Protected Mem.:
Attachment:
METAL
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
4-plies
Spec. No.:
MOD BIT: Granule Surface
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=10+
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg: Unknown
Unknown
Comments:
Thickness:
20.00
WOOD FIBERBOARD, POLYISOCYANURATE, PERLITE
Tapered:3Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
3.00 (IN)
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 1 of 5September 09, 2020
01644 - HISTORIC CALIBRATION BLDG
4/21/2000
Sec Name:
Original Construction: 1/1/1959Area:
B
5,484 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
0 (LF) 312 (LF)
0 (LF) 0 (LF)
0 (LF)
0 (LF)
Access: EXTERNAL LADDER: Permanent
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Beams, Girders, Columns
STEEL
1/8 in 12
GUTTERS & DOWNSPOUTS
NONE
Structure:
Roof Category: Membrane
ROOF EDGE: Embedded Edge Metal, PITCH PAN, ROOF RELIEF VENT
AGG: Crushed Stone
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
4-plies
Spec. No.:
NONE
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=10+
Base Flashing:
Counterflashing:
Membrane Mfg: Unknown
Unknown
Comments:
Thickness:
WOOD FIBERBOARD, PERLITE, POLYISOCYANURATE
Tapered:3Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
3.00 (IN)
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 2 of 5September 09, 2020
01644 - HISTORIC CALIBRATION BLDG
4/21/2000
Sec Name:
Original Construction: 1/1/1959Area:
C
109 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
0 (LF) 30 (LF)
0 (LF) 0 (LF)
15 (LF)
0 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
UNKNOWN
STEEL
1/8 in 12
ROOF EDGE
NONE
Structure:
Roof Category: Membrane
WALL/PARAPET, ROOF EDGE: Embedded Edge Metal
AGG: River Gravel
Description:
Protected Mem.:
Attachment:
METAL
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
Spec. No.:
MOD BIT: Granule Surface
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=10+
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg: Unknown
Unknown
Comments:
Thickness:
0.00
PERLITE, POLYISOCYANURATE, WOOD FIBERBOARD
Tapered:3Layers:
Types:
Attachment:
R-Value:
3.00 (IN)
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 3 of 5September 09, 2020
01644 - HISTORIC CALIBRATION BLDG
4/21/2000
Sec Name:
Original Construction: 1/1/1959Area:
D
48 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
0 (LF) 20 (LF)
0 (LF) 0 (LF)
10 (LF)
0 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
CONCRETE: Flat Slab
CONCRETE STD: Cast-In-Place
1/8 in 12
ROOF EDGE
NONE
Structure:
Roof Category: Membrane
WALL/PARAPET, ROOF EDGE: Embedded Edge Metal
AGG: River Gravel
Description:
Protected Mem.:
Attachment:
METAL
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
Spec. No.:
MOD BIT: Granule Surface
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=10+
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg:
Unknown
Comments:
Thickness:
0.00
WOOD FIBERBOARD, PERLITE, POLYISOCYANURATE
Tapered:3Layers:
Types:
Attachment:
R-Value:
3.00 (IN)
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 4 of 5September 09, 2020
Roof Section Inventory Report
Selection Criteria
Sort Criteria
Section Name Last Replacement Built Date Deck Type Roof Slope Section Area Membrane Attachment Facility Class Insulation Type Roof Type
All All All All All All All All All All
Section Name - Ascending
Page 5 of 5September 09, 2020
Building
Facility Class
Sec Name - Slope - Membrane Last Cons Year
Last Insp Year
Area
(SF)
RCIInsulation Type(s)
Deck Type
MCI-FCI-ICI
01644 - HISTORIC CALIBRATION
BLDG
Maintenance and Production
A - 1/8 - BUR: Asphalt 2000 201115,026 81
PERLITE, POLYISOCYANURATE, WOOD
FIBERBOARD
STEEL
93/75/---
B - 1/8 - BUR: Asphalt 2000 20115,484 78
PERLITE, POLYISOCYANURATE, WOOD
FIBERBOARD
STEEL
79/73/---
C - 1/8 - BUR: Asphalt 2000 2011109 84
PERLITE, POLYISOCYANURATE, WOOD
FIBERBOARD
STEEL
100/77/---
D - 1/8 - BUR: Asphalt 2000 201148 84
PERLITE, POLYISOCYANURATE, WOOD
FIBERBOARD
CONCRETE STD: Cast-In-Place
100/77/---
White Sands Missile Range (35995)
Roof Section RCI Report
Unassigned
Totals: Buildings = 1 Sections = 4 Area = 20,667
Page 1 of 2September 09, 2020
Roof Section RCI Report
Unassigned
Selection Criteria
Sort Criteria
Complex Number Complex Name Facility Number Section Name Facility Name Facility Class
RCI
Roof Type Insulation Type Deck Type Roof Slope Section Area Last Construction Year Last Inspection Year
All All All All All All All All All All All All All All
Complex Number - Ascending Complex Name - Ascending Facility Number - Ascending Section Name - Ascending
Page 2 of 2September 09, 2020
Date Inspected: Building:
Section:
01/31/2011 01644 - HISTORIC CALIBRATION BLDG
A
Category Code:
Maintenance and Production
COM ITM REP DOL
21887
Roof Section Area: 15,026 (SF)
Roofing Type: BUR: Asphalt
880 (LF)Flashing Length: Perimeter Length: Curb Length:696 (LF) 184 (LF)
Fasteners: (EA)
93MCI of Section:MCI of Section: EXCELLENT
FCI of Section: 75 Rating: VERY GOOD
ICI of Section: None Rating: None
RCI of Section: 80 Rating: MINOR REPAIRS NEEDED
Rating:
Severity Quantity
Flashing Distresses
Distress Type Density DeductDistresses of same type and severity are tallied
Embedded Edge Metal 5.45 18.2EM 48 (LF)Medium
Embedded Edge Metal 55.34 16.3EM 487 (LF)Low
Pitch Pans 4.47 23.3PP 39 (LF)High
Pitch Pans 4.47 10.4PP 39 (LF)Low
Severity Quantity
Membrane Distresses
Distress Type Density DeductDistresses of same type and severity are tallied
Debris and Vegetation 0.33 2.1DV 50 (SF)Medium
Improper Equip Supports 0.01 1.9EQ 2 (SF)High
Improper Equip Supports 0.08 4.9EQ 12 (SF)Low
Surface Deterioration 0.07 3.4SR 10 (SF)Medium
White Sands Missile Range (35995)
Roof Section Visual Inspection Summary
September 09, 2020 Page 1 of 4
01/29/2011 01644 - HISTORIC CALIBRATION BLDG
B
Category Code:
Maintenance and Production
COM ITM REP DOL
21887
Roof Section Area: 5,484 (SF)
Roofing Type: BUR: Asphalt
312 (LF)Flashing Length: Perimeter Length: Curb Length:312 (LF) 0 (LF)
Fasteners: (EA)
79MCI of Section:MCI of Section: VERY GOOD
FCI of Section: 73 Rating: VERY GOOD
ICI of Section: None Rating: None
RCI of Section: 75 Rating: MINOR REPAIRS NEEDED
Rating:
Severity Quantity
Flashing Distresses
Distress Type Density DeductDistresses of same type and severity are tallied
Embedded Edge Metal 9.94 23.6EM 31 (LF)Medium
Embedded Edge Metal 100.00 16.8EM 312 (LF)Low
Pitch Pans 1.05 10.2PP 3 (LF)High
Pitch Pans 2.10 6.1PP 7 (LF)Low
Severity Quantity
Membrane Distresses
Distress Type Density DeductDistresses of same type and severity are tallied
Debris and Vegetation 0.04 1.4DV 2 (SF)Medium
Surface Deterioration 0.51 13.0SR 28 (SF)High
Surface Deterioration 6.38 16.3SR 350 (SF)Medium
White Sands Missile Range (35995)
Roof Section Visual Inspection Summary
September 09, 2020 Page 2 of 4
01/29/2011 01644 - HISTORIC CALIBRATION BLDG
C
Category Code:
Maintenance and Production
COM ITM REP DOL
21887
Roof Section Area: 109 (SF)
Roofing Type: BUR: Asphalt
44 (LF)Flashing Length: Perimeter Length: Curb Length:44 (LF) 0 (LF)
Fasteners: (EA)
NoneMCI of Section:MCI of Section: None
FCI of Section: 77 Rating: VERY GOOD
ICI of Section: None Rating: None
RCI of Section: None Rating: None
Rating:
Severity Quantity
Flashing Distresses
Distress Type Density DeductDistresses of same type and severity are tallied
Embedded Edge Metal 6.82 20.1EM 3 (LF)Medium
Embedded Edge Metal 68.18 16.6EM 30 (LF)Low
White Sands Missile Range (35995)
Roof Section Visual Inspection Summary
September 09, 2020 Page 3 of 4
01/29/2011 01644 - HISTORIC CALIBRATION BLDG
D
Category Code:
Maintenance and Production
COM ITM REP DOL
21887
Roof Section Area: 48 (SF)
Roofing Type: BUR: Asphalt
29 (LF)Flashing Length: Perimeter Length: Curb Length:29 (LF) 0 (LF)
Fasteners: (EA)
NoneMCI of Section:MCI of Section: None
FCI of Section: 77 Rating: VERY GOOD
ICI of Section: None Rating: None
RCI of Section: None Rating: None
Rating:
Severity Quantity
Flashing Distresses
Distress Type Density DeductDistresses of same type and severity are tallied
Embedded Edge Metal 6.90 20.2EM 2 (LF)Medium
Embedded Edge Metal 68.97 16.6EM 20 (LF)Low ds Missile Range (35995)
Roof Section Visual Inspection Summary
September 09, 2020 Page 4 of 4
Building Use:
Building Type:
Construction
Year Constructed:
Building Area:
Number of Floors:
General Information
Date 9/9/2020 12:57:34 PM
21887 - COM ITM REP DOL
Wood, Light Frame
Permanent 20,667 (SF)
1959 1
Building: 01644 HISTORIC CALIBRATION BLDG
Roof Sections
Roof Category: BUR: Asphalt
A
B
C
D
Remarks
Key Plan
Building Identification Worksheet
Missile Range (35995) Unassigned
Page 1 of 19/9/20 12:57 PM
| Roofer B1530.pdf |
| Scanned from a Xerox Multifunction Printer |
| 1530-2 |
| Roofer B1644.pdf |
| 1644 - Roof Section Inspection Worksheet History |
| 1644 - Roof Section Inventory |