This solicitation package seeks proposals for roof repairs to three buildings at White Sands Missile Range in New Mexico. The contractor will be responsible for re-roofing buildings 1362, 1530, and 1644, furnishing all labor, materials, equipment, tools, transportation, bonds and other supplies needed to complete the work. The procurement will be set aside exclusively for Historically Underutilized Business Zone small businesses. The contract type will be firm-fixed-price with a period of performance of 200 calendar days. The NAICS code is 238160 and the estimated value is between $1,000,000 to $5,000,000. Interested offerors should review the attached solicitation and supporting documents for additional requirement details.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Appendix B

ROOFER Data

Supplied roofing data is from an assessment performed in 2011. Some information may have changed since the assessment.

Metal roof data is extremely limited.

Roof Penetration Legend:

Equipment Riser/Curb

Pitch Pan

Equipment Riser/Curb

Pipe, Typically Vent

D I S T R E S S

S E V E R I T Y

D E F E C T

Q U A N T I T Y

N U M B E R

Building:

Section:

01644 - HISTORIC CALIBRATION BLDG

A

Perimeter Flashing:

Curb Flashing:

696 (LF)

184 (LF)Inspection Date: 1/31/2011

Roof Type: Built-Up

Key Plan

Thru Panel Fasteners:

Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP)

Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV)

Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD)

Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)

1 EM L 1 487

2 EM M 1 48

3 PP L 1 12

4 DV M 1 50

5 PP H 4 12

6 EQ L 1 12

7 SR M 1 10

8 EQ H 2 2

Roof Section Inspection Worksheet History

White Sands Missile Range (35995) Unassigned

Page 1 of 4September 09, 2020

S T R E S S

S E V E R I T Y

D E F E C T

Q U A N T I T Y

N U M B E R

Building:

Section:

01644 - HISTORIC CALIBRATION BLDG

B

Perimeter Flashing:

Curb Flashing:

312 (LF)

0 (LF)Inspection Date: 1/29/2011

Roof Type: Built-Up

Key Plan

Thru Panel Fasteners:

Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP)

Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV)

Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD)

Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)

1 EM L 1 312

2 EM M 1 31

3 SR H 1 28

4 PP L 1 2

5 PP H 4 1

6 DV M 1 2

7 SR M 1 350

Roof Section Inspection Worksheet History

Page 2 of 4September 09, 2020

S T R E S S

S E V E R I T Y

D E F E C T

Q U A N T I T Y

N U M B E R

Building:

Section:

01644 - HISTORIC CALIBRATION BLDG

C

Perimeter Flashing:

Curb Flashing:

44 (LF)

0 (LF)Inspection Date: 1/29/2011

Roof Type: Built-Up

Key Plan

Thru Panel Fasteners:

Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP)

Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV)

Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD)

Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)

1 EM L 1 30

2 EM M 1 3

Roof Section Inspection Worksheet History

Page 3 of 4September 09, 2020

S T R E S S

S E V E R I T Y

D E F E C T

Q U A N T I T Y

N U M B E R

Building:

Section:

01644 - HISTORIC CALIBRATION BLDG

D

Perimeter Flashing:

Curb Flashing:

29 (LF)

0 (LF)Inspection Date: 1/29/2011

Roof Type: Built-Up

Key Plan

Thru Panel Fasteners:

Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP)

Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV)

Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD)

Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)

1 EM L 1 20

2 EM M 1 2

Roof Section Inspection Worksheet History

Page 4 of 4September 09, 2020

Building:

Last Replacement:Occupancy:

01644 - HISTORIC CALIBRATION BLDG

4/21/2000

Sec Name:

Original Construction: 1/1/1959Area:

A

15,026 (SF)

Layout:

Parapet: Roof Edge:

Exp. Joint:

Adj. Wall:

Area Div.: Other:

0 (LF) 487 (LF)

0 (LF) 0 (LF)

210 (LF)

0 (LF)

Access: EXTERNAL LADDER: Permanent

Structural Frame:

Roof Deck:

Vapor Retarder:

Drainage:

Slope:

STEEL: Bar Joists/Combination

STEEL

1/8 in 12

GUTTERS & DOWNSPOUTS

NONE

Structure:

Roof Category: Membrane

ROOF EDGE: Embedded Edge Metal, PITCH PAN, EQUIPMENT SUPPORT: Curbs, PLUMBING VENT, ROOF

PENETRATION, WALL/PARAPET

AGG: Crushed Stone

Description:

Protected Mem.:

Attachment:

METAL

NONE

Flashing Adhesive:

Types:

Walkways:

BUR: Asphalt

4-plies

Spec. No.:

MOD BIT: Granule Surface

Reinforcement:

Type:

B.U.(HOT/COLD): Glass Felt

No

Surfacing:

ERSL W/=10+

ERSL W/O=10+

Base Flashing:

Counterflashing:

HOT MOPPED

Membrane Mfg: Unknown

Unknown

Comments:

Thickness:

20.00

WOOD FIBERBOARD, POLYISOCYANURATE, PERLITE

Tapered:3Layers:

ADHESIVE - HOT

Types:

Attachment:

R-Value:

3.00 (IN)

Membrane:

Insulation:

No

Flashing:

Roof Section Inventory Report

Page 1 of 5September 09, 2020

01644 - HISTORIC CALIBRATION BLDG

4/21/2000

Sec Name:

Original Construction: 1/1/1959Area:

B

5,484 (SF)

Layout:

Parapet: Roof Edge:

Exp. Joint:

Adj. Wall:

Area Div.: Other:

0 (LF) 312 (LF)

0 (LF) 0 (LF)

0 (LF)

0 (LF)

Access: EXTERNAL LADDER: Permanent

Structural Frame:

Roof Deck:

Vapor Retarder:

Drainage:

Slope:

STEEL: Beams, Girders, Columns

STEEL

1/8 in 12

GUTTERS & DOWNSPOUTS

NONE

Structure:

Roof Category: Membrane

ROOF EDGE: Embedded Edge Metal, PITCH PAN, ROOF RELIEF VENT

AGG: Crushed Stone

Description:

Protected Mem.:

Attachment:

NONE

NONE

Flashing Adhesive:

Types:

Walkways:

BUR: Asphalt

4-plies

Spec. No.:

NONE

Reinforcement:

Type:

B.U.(HOT/COLD): Glass Felt

No

Surfacing:

ERSL W/=10+

ERSL W/O=10+

Base Flashing:

Counterflashing:

Membrane Mfg: Unknown

Unknown

Comments:

Thickness:

WOOD FIBERBOARD, PERLITE, POLYISOCYANURATE

Tapered:3Layers:

ADHESIVE - HOT

Types:

Attachment:

R-Value:

3.00 (IN)

Membrane:

Insulation:

No

Flashing:

Roof Section Inventory Report

Page 2 of 5September 09, 2020

01644 - HISTORIC CALIBRATION BLDG

4/21/2000

Sec Name:

Original Construction: 1/1/1959Area:

C

109 (SF)

Layout:

Parapet: Roof Edge:

Exp. Joint:

Adj. Wall:

Area Div.: Other:

0 (LF) 30 (LF)

0 (LF) 0 (LF)

15 (LF)

0 (LF)

Access: EXTERNAL LADDER: Temporary

Structural Frame:

Roof Deck:

Vapor Retarder:

Drainage:

Slope:

UNKNOWN

STEEL

1/8 in 12

ROOF EDGE

NONE

Structure:

Roof Category: Membrane

WALL/PARAPET, ROOF EDGE: Embedded Edge Metal

AGG: River Gravel

Description:

Protected Mem.:

Attachment:

METAL

NONE

Flashing Adhesive:

Types:

Walkways:

BUR: Asphalt

Spec. No.:

MOD BIT: Granule Surface

Reinforcement:

Type:

B.U.(HOT/COLD): Glass Felt

No

Surfacing:

ERSL W/=10+

ERSL W/O=10+

Base Flashing:

Counterflashing:

HOT MOPPED

Membrane Mfg: Unknown

Unknown

Comments:

Thickness:

0.00

PERLITE, POLYISOCYANURATE, WOOD FIBERBOARD

Tapered:3Layers:

Types:

Attachment:

R-Value:

3.00 (IN)

Membrane:

Insulation:

No

Flashing:

Roof Section Inventory Report

Page 3 of 5September 09, 2020

01644 - HISTORIC CALIBRATION BLDG

4/21/2000

Sec Name:

Original Construction: 1/1/1959Area:

D

48 (SF)

Layout:

Parapet: Roof Edge:

Exp. Joint:

Adj. Wall:

Area Div.: Other:

0 (LF) 20 (LF)

0 (LF) 0 (LF)

10 (LF)

0 (LF)

Access: EXTERNAL LADDER: Temporary

Structural Frame:

Roof Deck:

Vapor Retarder:

Drainage:

Slope:

CONCRETE: Flat Slab

CONCRETE STD: Cast-In-Place

1/8 in 12

ROOF EDGE

NONE

Structure:

Roof Category: Membrane

WALL/PARAPET, ROOF EDGE: Embedded Edge Metal

AGG: River Gravel

Description:

Protected Mem.:

Attachment:

METAL

NONE

Flashing Adhesive:

Types:

Walkways:

BUR: Asphalt

Spec. No.:

MOD BIT: Granule Surface

Reinforcement:

Type:

B.U.(HOT/COLD): Glass Felt

No

Surfacing:

ERSL W/=10+

ERSL W/O=10+

Base Flashing:

Counterflashing:

HOT MOPPED

Membrane Mfg:

Unknown

Comments:

Thickness:

0.00

WOOD FIBERBOARD, PERLITE, POLYISOCYANURATE

Tapered:3Layers:

Types:

Attachment:

R-Value:

3.00 (IN)

Membrane:

Insulation:

No

Flashing:

Roof Section Inventory Report

Page 4 of 5September 09, 2020

Roof Section Inventory Report

Selection Criteria

Sort Criteria

Section Name Last Replacement Built Date Deck Type Roof Slope Section Area Membrane Attachment Facility Class Insulation Type Roof Type

All All All All All All All All All All

Section Name - Ascending

Page 5 of 5September 09, 2020

Building

Facility Class

Sec Name - Slope - Membrane Last Cons Year

Last Insp Year

Area

(SF)

RCIInsulation Type(s)

Deck Type

MCI-FCI-ICI

01644 - HISTORIC CALIBRATION

BLDG

Maintenance and Production

A - 1/8 - BUR: Asphalt 2000 201115,026 81

PERLITE, POLYISOCYANURATE, WOOD

FIBERBOARD

STEEL

93/75/---

B - 1/8 - BUR: Asphalt 2000 20115,484 78

PERLITE, POLYISOCYANURATE, WOOD

FIBERBOARD

STEEL

79/73/---

C - 1/8 - BUR: Asphalt 2000 2011109 84

PERLITE, POLYISOCYANURATE, WOOD

FIBERBOARD

STEEL

100/77/---

D - 1/8 - BUR: Asphalt 2000 201148 84

PERLITE, POLYISOCYANURATE, WOOD

FIBERBOARD

CONCRETE STD: Cast-In-Place

100/77/---

White Sands Missile Range (35995)

Roof Section RCI Report

Unassigned

Totals: Buildings = 1 Sections = 4 Area = 20,667

Page 1 of 2September 09, 2020

Roof Section RCI Report

Unassigned

Selection Criteria

Sort Criteria

Complex Number Complex Name Facility Number Section Name Facility Name Facility Class

RCI

Roof Type Insulation Type Deck Type Roof Slope Section Area Last Construction Year Last Inspection Year

All All All All All All All All All All All All All All

Complex Number - Ascending Complex Name - Ascending Facility Number - Ascending Section Name - Ascending

Page 2 of 2September 09, 2020

Date Inspected: Building:

Section:

01/31/2011 01644 - HISTORIC CALIBRATION BLDG

A

Category Code:

Maintenance and Production

COM ITM REP DOL

21887

Roof Section Area: 15,026 (SF)

Roofing Type: BUR: Asphalt

880 (LF)Flashing Length: Perimeter Length: Curb Length:696 (LF) 184 (LF)

Fasteners: (EA)

93MCI of Section:MCI of Section: EXCELLENT

FCI of Section: 75 Rating: VERY GOOD

ICI of Section: None Rating: None

RCI of Section: 80 Rating: MINOR REPAIRS NEEDED

Rating:

Severity Quantity

Flashing Distresses

Distress Type Density DeductDistresses of same type and severity are tallied

Embedded Edge Metal 5.45 18.2EM 48 (LF)Medium

Embedded Edge Metal 55.34 16.3EM 487 (LF)Low

Pitch Pans 4.47 23.3PP 39 (LF)High

Pitch Pans 4.47 10.4PP 39 (LF)Low

Severity Quantity

Membrane Distresses

Distress Type Density DeductDistresses of same type and severity are tallied

Debris and Vegetation 0.33 2.1DV 50 (SF)Medium

Improper Equip Supports 0.01 1.9EQ 2 (SF)High

Improper Equip Supports 0.08 4.9EQ 12 (SF)Low

Surface Deterioration 0.07 3.4SR 10 (SF)Medium

White Sands Missile Range (35995)

Roof Section Visual Inspection Summary

September 09, 2020 Page 1 of 4

01/29/2011 01644 - HISTORIC CALIBRATION BLDG

B

Category Code:

Maintenance and Production

COM ITM REP DOL

21887

Roof Section Area: 5,484 (SF)

Roofing Type: BUR: Asphalt

312 (LF)Flashing Length: Perimeter Length: Curb Length:312 (LF) 0 (LF)

Fasteners: (EA)

79MCI of Section:MCI of Section: VERY GOOD

FCI of Section: 73 Rating: VERY GOOD

ICI of Section: None Rating: None

RCI of Section: 75 Rating: MINOR REPAIRS NEEDED

Rating:

Severity Quantity

Flashing Distresses

Distress Type Density DeductDistresses of same type and severity are tallied

Embedded Edge Metal 9.94 23.6EM 31 (LF)Medium

Embedded Edge Metal 100.00 16.8EM 312 (LF)Low

Pitch Pans 1.05 10.2PP 3 (LF)High

Pitch Pans 2.10 6.1PP 7 (LF)Low

Severity Quantity

Membrane Distresses

Distress Type Density DeductDistresses of same type and severity are tallied

Debris and Vegetation 0.04 1.4DV 2 (SF)Medium

Surface Deterioration 0.51 13.0SR 28 (SF)High

Surface Deterioration 6.38 16.3SR 350 (SF)Medium

White Sands Missile Range (35995)

Roof Section Visual Inspection Summary

September 09, 2020 Page 2 of 4

01/29/2011 01644 - HISTORIC CALIBRATION BLDG

C

Category Code:

Maintenance and Production

COM ITM REP DOL

21887

Roof Section Area: 109 (SF)

Roofing Type: BUR: Asphalt

44 (LF)Flashing Length: Perimeter Length: Curb Length:44 (LF) 0 (LF)

Fasteners: (EA)

NoneMCI of Section:MCI of Section: None

FCI of Section: 77 Rating: VERY GOOD

ICI of Section: None Rating: None

RCI of Section: None Rating: None

Rating:

Severity Quantity

Flashing Distresses

Distress Type Density DeductDistresses of same type and severity are tallied

Embedded Edge Metal 6.82 20.1EM 3 (LF)Medium

Embedded Edge Metal 68.18 16.6EM 30 (LF)Low

White Sands Missile Range (35995)

Roof Section Visual Inspection Summary

September 09, 2020 Page 3 of 4

01/29/2011 01644 - HISTORIC CALIBRATION BLDG

D

Category Code:

Maintenance and Production

COM ITM REP DOL

21887

Roof Section Area: 48 (SF)

Roofing Type: BUR: Asphalt

29 (LF)Flashing Length: Perimeter Length: Curb Length:29 (LF) 0 (LF)

Fasteners: (EA)

NoneMCI of Section:MCI of Section: None

FCI of Section: 77 Rating: VERY GOOD

ICI of Section: None Rating: None

RCI of Section: None Rating: None

Rating:

Severity Quantity

Flashing Distresses

Distress Type Density DeductDistresses of same type and severity are tallied

Embedded Edge Metal 6.90 20.2EM 2 (LF)Medium

Embedded Edge Metal 68.97 16.6EM 20 (LF)Low ds Missile Range (35995)

Roof Section Visual Inspection Summary

September 09, 2020 Page 4 of 4

Building Use:

Building Type:

Construction

Year Constructed:

Building Area:

Number of Floors:

General Information

Date 9/9/2020 12:57:34 PM

21887 - COM ITM REP DOL

Wood, Light Frame

Permanent 20,667 (SF)

1959 1

Building: 01644 HISTORIC CALIBRATION BLDG

Roof Sections

Roof Category: BUR: Asphalt

A

B

C

D

Remarks

Key Plan

Building Identification Worksheet

Missile Range (35995) Unassigned

Page 1 of 19/9/20 12:57 PM

Roofer B1530.pdf
Scanned from a Xerox Multifunction Printer
1530-2
Roofer B1644.pdf
1644 - Roof Section Inspection Worksheet History
1644 - Roof Section Inventory
1644 - Roof Section RCI
1644 - Roof Section Visual Inspection Summary
1644 Roofer Building Identification Worksheet

File details come from the government source that posted it. Updated .