ARL047479P-_PLANS_AND_DRAWINGS_-_28_AUGUST_2019_-Final_Design_Upgrade.pdf

PDF 3 MB Posted

Attached to
REPAIR/ REPLACE ELECTRICAL SYSTEM
Solicitation number
W911SG19B0005
Issued by

About this file

ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -Final Design Upgrade

View the file

Other files

File Type Posted
SF1419A-W911SG19B0005_page_2.pdf PDF
SF1419A-W911SG19B0005_page_3.pdf PDF
SF1419-W911SG19B0005_page_1.pdf PDF
BID_OPENING_SIGN_IN_SHEET_-_W911SG19B0005.pdf PDF
PANEL_A2_-_Room_134.pdf PDF
FUSE_DISCONNECT_-_Room_120_Hallway.pdf PDF
PANEL_E_-_Room_123B.pdf PDF
PANEL_F_-_Room_127.pdf PDF
PANEL_A1_-_Room_134.pdf PDF
PANEL_R2_-_Room_123_Hallway.pdf PDF
PANEL_D_-_Room_133.pdf PDF
PANEL_H_-_Room_133.pdf PDF
PANEL_R4_-_Room_122.pdf PDF
PANEL_RM_-_Room_123B.pdf PDF
SOLICITATION_AMENDMENT_01_-_W911SG19B0005.pdf PDF
PANEL_P_Right_Side_-_Room_133.pdf PDF
PANEL_R5_-_Room_119.pdf PDF
FUSE_DISCONNECT_-_Room_119.pdf PDF
Specification_Rodent_Droppings_Remediation.pdf PDF
PANEL_K_-_Room_129.pdf PDF
PANEL_123C_-_Room_123C.pdf PDF
PANEL_C_-_Room_130_Hallway.pdf PDF
PANEL_P_Left_Side_-_Room_133.pdf PDF
SOLICITATION_AMENDMENT(M)_01_-_W911SG19B0005.pdf PDF
PANEL_RG_Left_and_Right_Sides_-_Outside_Rooms_105_and_106.pdf PDF
MICC_WSMR_Repair-Replace_Electrical_System_Site_Visit_Pre-Bid_Conference_PowerPoint.pdf PDF
SIGN_IN_SHEET-WSMR_Repair-Replace_Electrical_System_W911SG19B0005.pdf PDF
ARL047479P-_PLANS_AND_DRAWINGS_-_W911SG19B0005.pdf PDF
SOLICITATION__-_W911SG19B0005.pdf PDF
52.218-4201_UXO_POLICY.pdf PDF
WSMR_Visitor_Control_Program_May_2017.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET INDEX

DRAWING NUMBER TITLE

WS-25900-2019-G-G1-01 Building 25900 COVER SHEET/INDEX SHEET

WS-25900-2019-O-G1-02 PROPOSED STAGING AREA AT 25900

WS-25900-2019-EP-03 Building 25900 PANEL AND TRANSFORMER LAYOUT

WS-25900-2019-EP-04 Building 25900 ROOM 134 PANEL "A1" WS-25900-2019-EP-05 Building 25900 ROOM 134 PANEL "A2" WS-25900-2019-EP-06 Building 25900 PANEL "P" WS-25900-2019-EP-07 Building 25900 ROOM 129 PANEL "C" AND "K" WS-25900-2019-EP-08 Building 25900 ROOM 123 PANEL "OUTSIDE ROOM 123B" WS-25900-2019-EP-09 Building 25900 ROOM 127 PANEL "F" WS-25900-2019-EP-10 Building 25900 ROOM 123B PANEL "E"

WS-25900-2019-EP-11 BUILDING 25900 ROOM 123B PANEL "RM"

WS-25900-2019-EP-12 BUILDING 25900 ROOM 123C PANEL "123C"

WS-25900-2019-EP-13 BUILDING 25900 ROOM 122 PANEL "R4"

WS-25900-2019-EP-14 BUILDING 25900 ROOM 119 PANEL "R5"

WS-25900-2019-EP-15 BUILDING 25900 ROOMS 105 & 106 PANEL "G"

WS-25900-2019-EP-16 BUILDING 25900 ROOM 133 PANEL "H"

WS-25900-2019-EP-17 BUILDING 25900 ROOM 133 PANEL "D"

WS-25900-2019-EP-18 GENERAL NOTES

WS-25900-2019-EP-19 GENERAL NOTES

DESIGNED

CHIEF, ENGINEERING DIVISION

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

ARCH D

DRAWING TITLE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

CESAR M. LIMON

VANESSA CUEVAS

RAFAEL H. ACOSTA

NTS

BUILDING 25900 REPLACE ELECTRICAL PANELS

WS-25900-2019-G-G1-01

COVER SHEET / INDEX SHEET

BUILDING 25900

1 19

CESAR M. LIMON

W H

I T E

S ANDS MIS S I LE

RA

NG

E

B I RTHPLACE

OF

AMERI CA' S MI SSI LE & SPACE

AC

TI

V

IT

Y

CONCURRENCES

Note: Signatures affixed on this sheet indicate official recommendation and approval of all the drawings in this set as indexed on this sheet.

Garrison Safety

Physical Security

Fire Department

DPW Environmental

Anti-Terrorism/Force Protection

Information Management

Operations and Maintenance Division

Customer 1

Date

Date

Date

Date

Date

Date

Date

Date

Customer 2 Date

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

AutoCAD SHX Text

WHITE SANDS MISSILE RANGE, NEW MEXICO

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS

AutoCAD SHX Text

ENGINEERING DIVISION

DESIGNED

CHIEF, ENGINEERING DIVISION

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-02

PROPOSED STAGING AREA

AT 25900

RAFAEL ACOSTA

2 19

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

ARCH D

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-3

BUILDING 25900

PANEL AND

TRANSFORMER LAYOUT

BUILDING 25900 LAYOUT

KEY NOTES

RAFAEL ACOSTA

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

5 6

PANELS A1 & A2

208 / 120 V

3 PHASE

PANEL DETAIL: SHEETS 6

WS-25900-2019-EP-6 AND

7 WS-25900-2019-EP-7

3 PANELS RG

208 / 120 V

3 PHASE

PANEL DETAIL: SHEETS 17 WS-25900-2019-EP-17

THERE ARE TWO PANELS.

4 PANEL R2

208 / 120 V

3 PHASE

FED FROM SWITCHBOARD BREAKER #14

SHEET 15 WS-25900-2019-EP-10

PANEL DETAIL: SHEETS 10 WS-25900-2019-EP-10

5 PANEL E

208 / 120 V

3 PHASE

PANEL DETAIL: SHEET 12 WS-25900-2019-EP-12

6 PANEL RM

208 / 120 V

3 PHASE

PANEL DETAIL: SHEET 13 WS-25900-2019-EP-13

7 PANEL 123C

208 / 120 V

3 PHASE

PANEL DETAIL: SHEET 14 WS-25900-2019-EP-14

8 PANEL R4

208 / 120 V

3 PHASE

PANEL DETAIL: SHEET 15 WS-25900-2019-EP-15

9 PANEL R5

208 / 120 V

3 PHASE

PANEL DETAIL: SHEET 16 WS-25900-2019-EP-16

10 PANEL D

208 / 120 V

3 PHASE

PANEL DETAIL: SHEET 19 WS-25900-2019-EP-19

11 PANEL H

480 / 277 V

3 PHASE

PANEL DETAIL: SHEET 18 WS-25900-2019-EP-18

12 PANEL P

480 / 277 V

3 PHASE

PANEL DETAIL: SHEET 8 WS-25900-2019-EP-8

THESE TWO PANELS SHALL BE COMBINED INTO ONE

PANEL.

19 20

14 PANEL C

208 / 120 V

3 PHASE

PANEL DETAIL: SHEET 9

WS-25900-2019-EP-9

DRY TYPE TRANSFORMER, 3 PHASE, 45 KVA

480 / 277 V-208 / 120 V

FED FROM SWITCHBOARD BREAKER #3

IN MECHANICAL ROOM 133

DRY TYPE TRANSFORMER, 3 PHASE, 112.5 KVA

480 / 277 V-208 / 120 V

FED FROM SWITCHBOARD BREAKER #3 IN MECHANICAL

ROOM 133

PANEL F

208 / 120 V

3 PHASE

PANEL DETAIL: SHEET 11 WS-25900-

2019-EP-11

PANEL K

208 / 120 V

3 PHASE

PANEL DETAIL: SHEET 9

WS-25900-2019-EP-9

21 OIL FILLED PADMOUNT TRANSFORMER, 3 PHASE,

1500 KVA

24900 / 14376 V-480 / 277 V

FED FROM SWITCHBOARD BREAKER #3 IN MECHANICAL

ROOM 133

PANELS AND DISCONNECT SWITCHES THAT ARE

SPECIFIED TO BE REPLACED AS FOLLOWS:

THE FOLLOWING ARE DISTRIBUTION TRANSFORMERS

THAT FEED 3 PHASE PANELS 208 / 120 V :

17 FUSE DISCONNECT (FOR PANEL R5)

240 V

3 PHASE

ARCH D

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

AutoCAD SHX Text 178'-1 3/4"

AutoCAD SHX Text 103'-4 1/16"

AutoCAD SHX Text 179'-10 11/16"

AutoCAD SHX Text 41'-3 3/16"

AutoCAD SHX Text 61'-4 15/16"

AutoCAD SHX Text 65'-11 5/8"

AutoCAD SHX Text 48'-2 5/16"

AutoCAD SHX Text 90'-2 1/8"

AutoCAD SHX Text 52'-2 3/16"

AutoCAD SHX Text 43'-9 15/16"

AutoCAD SHX Text 8'-2 3/4"

AutoCAD SHX Text 41'-4 15/16"

AutoCAD SHX Text 24'-5 7/16"

AutoCAD SHX Text N

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SWITCHGEAR

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL ROOM

AutoCAD SHX Text

BOILER ROOM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 103A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 9'-7 11/16"

AutoCAD SHX Text 16'-7 11/16"

AutoCAD SHX Text 10'-1 5/16"

AutoCAD SHX Text 6'-2 5/16"

AutoCAD SHX Text

AutoCAD SHX Text 123C

AutoCAD SHX Text 123B

AutoCAD SHX Text 123A

AutoCAD SHX Text 1/16"=1'-0"

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-04

BUILDING 25900

ROOM 134

PANEL "A1"

GENERAL NOTES

EXISTING SUB PANEL "A1"

208 / 120 V, 3 PHASE, SURFACE MOUNTED BOTTOM FEED, 4 W 225A MAIN WITH LUGS ONLY

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

1 20 Lights Trasnf. Room 2 1 20 Do

1 20 Do 4 1 20 Do

1 20 Do 6 1 20 Do

1 20 Do 8 1 20 Do

1 20 Do 10 1 20 Do

1 20 Do 12 1 20 Do

1 20 Do 14 1 20 Lights Trasnf. Room

1 20 Do 16 1 20 Do

17 1 20 Do 18 1 20 Do

19 1 20 RECP. HIGH BAY 20 1 20 Do

1 20 RECP. HIGH BAY 22 1 20 Do

1 20 4 EVAP PUMP

MOTORS 24 1 20 Do

3 70 PANEL "L" 26 1 20

Contr. Fltr Room Lights

3 70 " 28 1 20 SPARE

3 70 " 30 1 20 Flood Lights

3 30 3 Phase Recept. 32 3 20 Do

33 3 30 " 34 3 20 Do

35 3 30 " 36 3 20 Do

RAFAEL ACOSTA

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

1) PANEL DIMENSIONS

LENGTH: 47 INCHES

WIDTH: 20 1/2 INCHES

DEPTH: 6 INCHES

ARCH D

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-05

BUILDING 25900

ROOM 134

PANEL "A2"

EXISTING SUB PANEL "A2"

208 / 120 V, 3 PHASE, SURFACE MOUNTED BOTTOM FEED, 4 W 225A MAIN WITH LUGS ONLY

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

1 20 Recept. Transf. Room 2 1 20 Do

1 20 Do 4 1 20 OT Alarm & Freeze

UPL

1 20 Recept. Transf. Room 6 3 20 Cardox Cont.

1 20 Recept. Transf. Room 8 3 20 Xmilt

1 20 Recept. Transf. Room 10 3 20 Fire Contr.

ACUNNITT Rm

1 20 Recept. Transf. Room 12 1 20 Fire Contr. Ex.

Motors

1 20 Recept. Tr Control 14 1 20

Recept. Tr.

Rm./Damper Motor

1 20 Recept. TR Control 16 3 20 Recept. Sw Board

Room

17 1 20 Recept. Ex. Mtr. Rm

122 18 3 20 Recept. Sw Board Room

19 1 20 Outside BR Light 20 3 20 Recept. Sw Board

Room

1 20 Lights Swboard

Room 22 1 20 Driver Rm. Cir

1 20 Lights Swboard Room 24 1 20 Corr. 116 Lights

1 20 Lights Swboard

Room 26 1 20 Recept. Trans. Rm

1 20 Warning System 28 1 20 28 Volt UnReg

1 20 Warning System 30 1 Blank

1 20 Outside Bracketline 32 1 Blank

33 2 20 Heater Wave Guide

HSC 34 3 20 Phase Do

35 2 20 " 36 3 20

37 3 20 Phase Do 38 3 20 "

39 3 20 " 40 3 30 Phase Do

41 3 20 " 42 3 30

44 3 30

RAFAEL ACOSTA

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

1) PANEL DIMENSIONS

LENGTH: 51 INCHES

WIDTH: 20 INCHES

DEPTH: 6 INCHES

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

GENERAL NOTES

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-06

BUILDING 25900

PANEL "P1" AND "P2"

EXISTING PANEL "P1" MECHANICAL

ROOM

480 / 277 V, 3 PHASE, SURFACE MOUNTED BOTTOM FEED, 4 W WITH 150A MAIN BREAKER

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

3 15 SPARE 2 3 15 SHREDOR

3 15 " 4 3 15 "

3 15 " 6 3 15 "

3 30 CONDENSOR UNIT 8 3 30 SPARE

3 30 " 10 3 30 "

3 30 " 12 3 30 "

RAFAEL ACOSTA

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

480 / 277 V, 3 PHASE, SURFACE MOUNTED BOTTOM FEED, 4 W WITH 150A MAIN BREAKER

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

3 40 COAKITE HEATER 2 3 15 HOT WATER PUMP

3 40 " 4 3 15 "

3 40 " 6 3 15 "

3 15 1

2 HP EXH. 8 3 15 1

2 HP EXH.

3 15 " 10 3 15 "

3 15 " 12 3 15 "

3 15 AIR COMPRESSOR 14 BLANK

3 15 " 16 BLANK

3 15 " 18 BLANK

3 15

AIR HANDLING

UNIT TRANS.

ROOM

20 3 15 CHILLED WATER

PUMP

3 15 " 22 3 15 "

3 15 " 24 3 15 "

3 20 EXHANSTER 8 26 3 20 SPARE

3 20 " 28 3 20 SPARE

3 20 " 30 3 20 SPARE

BLANK 32 3 20 SPARE

BLANK 34 3 20 SPARE

BLANK 36 3 20 SPARE

3 30 SPARE 38 BLANK'

3 30 SPARE 40 BLANK

3 30 SPARE 42 BLANK

EXISTING PANEL "P2" MECHANICAL

ROOM

1) PANEL DIMENSIONS

LENGTH: 51 INCHES

WIDTH: 20 1/2 INCHES

DEPTH: 6 INCHES

NOTES:

BOTH PANELS "P1" AND "P2" SHALL BE COMBINED INTO ONE PANEL AND WITH CORRECT SIZE OF BREAKERS

FOR EACH DEVICE WITH A MAIN BREAKER.

1) PANEL DIMENSIONS

LENGTH: 51 INCHES

WIDTH: 20 1/2 INCHES

DEPTH: 6 INCHES

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

NGENERAL NOTES

GENERAL NOTES

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-7

BUILDING 25900

ROOM 129

PANEL "C" AND "K"

7 19

EXISTING SUB PANEL "C"

208 / 120 V, 3 PHASE, SURFACE MOUNTED BOTTOM FEED, 4 W 225A MAIN WITH LUGS ONLY

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

1 20 RECP.

WORKSHOP SHOP 2 1 20 RECP.

WORKSHOP SHOP

1 20 RECP.

WORKSHOP SHOP 4 1 20 RECP. WORKSHOP

SHOP

1 20

Recept. Work Shop (note this has been crossed-out on label with pencil)

6 1 20 RECP. WORKSHOP

SHOP

1 20

EMERGENCY

LIGHTS (note:

breaker in OFF position)

8 1 20 NO Label (note:

breaker in ON

Position)

1 20 HALL LIGHTS 10 1 20 RECEPT. BOILER

ROOM

1 20

BOILER

CONTROL (note: lab el on breaker “Fire Pump Cont”)

12 1 20 SPARE (note: breaker in ON position)

1 20

SPARE (note:

breaker in ON position) 14 1 20

No Label (note:

breaker in ON position)

1 20

SPARE (note:

breaker in ON position) 16 1 20 SPARE (note: breaker in ON position)

17 1

SPARE (note:

breaker in ON position)

18 1 20 ROOM 129 RECPT.

SW

19 1

20 ROOM 129 REC SW 20 1 20 ROOM 129 RECPT.

SW

1 20 ROOM 117 RECEPT.

110 VOLT 22 1 20 ROOM 129 SW

2 20 PUMP (note: label on breaker “Pump Blue”) 24 BLANK

BLANK 26 3 20 208 3 PHASE ROOM

3 50 ELECTRIC WATER

HEATER 28 3 20 "

3 50 " 30 3 20

3 50 208 V 3 PHASE

ROOM 117 32 3 50

Room 129 220-V Computer Power

3 20 " 34 3 50 "

35 3 20 " 36 3 50 "

RAFAEL ACOSTA

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

1) PANEL DIMENSIONS

LENGTH: 47 INCHES

WIDTH: 20 1/2 INCHES

DEPTH: 6 INCHES

EXISTING SUB PANEL "K"

208 / 120 V, 3 PHASE, SURFACE MOUNTED BOTTOM FEED, 4 W 100 A MAIN BREAKER

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

BLANK 2 BLANK

1 20 DISC. #1 4 1 20 DISC. #2

1 BLANK 6 BLANK

1 BLANK 8 BLANK

1 20 DISC. #3 10 1 20 DISC. #4

1 BLANK 12 BLANK

1 BLANK 14 BLANK

1 20 DISC. #5 16 1 20 DISC. #6

17 1

BLANK 18 BLANK

19 1

BLANK 20 BLANK

1 20 DISC. #7 22 BLANK

1) PANEL DIMENSIONS

LENGTH: 34 INCHES

WIDTH: 20 INCHES

DEPTH: 6 INCHES

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

GENERAL NOTES

GENERAL NOTES

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-08

BUILDING 25900

ROOM 123

PANEL "OUTSIDE ROOM

123B"

8 19

EX

IS

TI

N

G S

U B

P A

N

EL

3B

/ 1

V , 3

P H

A

SE

, S U

R

FA

C E

M O

U N

TE

D

B O

TT

O

M F

EE

D

, 4 W

A M

A

IN

W

IT

H L

U G

S O

N

LY

C K

T.

N

O

PO

LE

S

TR

IP

(A

M

PS

SE

R V

IC

ES

A B

C

Su pe rv is or

's Pl ay A

Su pe rv is or 's

D is pl ay

A

T ap e

Er as er

Sp ar e

A

Eq ui pm en t A

D

A

A

R

IT

A U

X

PC

T w o

Tr ig . D is t.

M ai n

R

IT

PC

O ne

T rig

D is t.

U til

R

TI

T rig

R

TI

O ne M ai n

R

TI

Sp ar e

Sp ar e

Sp ar e

A

Sp ar e

Sp ar e

Te ch ni ca l A re a

Te ch ni ca l A re a

B uf fe r

Sp ar e

Sp ar e

Sp ar e

Sp ar e

Sp ar e

RAFAEL ACOSTA

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

1) PANEL DIMENSIONS

LENGTH: 79 INCHES

WIDTH: 12 INCHES

DEPTH: 6 INCHES

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-09

BUILDING 25900

ROOM 127

PANEL "F"

09 19

EXISTING SUB PANEL "F"

208 / 120 V, 3 PHASE, SURFACE MOUNTED BOTTOM FEED, 4 W 225 A MAIN BREAKER

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

1 20 LIGHTS 2 3 20 GRINDER 208 V

1 20 " 4 3 20 "

1 20

RECEPT. W. WALL

(110 VOLT) 6 3 20 "

1 20

RECEPT. W. WALL

(110 VOLT) 8 1 20 RECEPT.

1 20

RECEPT. W. WALL

(110 VOLT) 10 1 20 RECEPT. (110 V)

1 20 RECEP. WALL M.

TABLE 12 1 20

RECEP. W. WALL

(110 V)

1 20

RECEP. N. WALL

(110 V) 14 1 20

RECEP. E. WALL

(110 V)

1 20

RECEP. N. WALL

(110 V) 16 1 20

RECEP. E. WALL

(110 V)

17 1

RECEP. S. WALL

(110 V) 18 1 20

RECEP. E. WALL

(110 V)

19 1

RECEP. E. WALL

(110 V) 20 1 20

RECEP. E. WALL

(110 V)

1 20 SAW AND

GRINDER 22 1 20 MONO RAIL

1 20 MONO RAIL 24 1 20 SPARE

1 20 SPARE 26 1 20 RCVR. RACK

1 20 EXH. FAN 28 2 20

SPARE

3 20 3 PHASE MILLING

MACHINE 30 2 20 SPARE

3 20 " 32 3 20

MILLING

MACHINE 3 PHASE

208 V

33 3 20 " 34 3 20 "

35 3

LATHE (208 V 3

PHASE) &

GRINDER

36 3 20

37 3 40 " 38

39 3 40 "

RAFAEL ACOSTA

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

1) PANEL DIMENSIONS

LENGTH: 34 INCHES

WIDTH: 20 1/2 INCHES

DEPTH: 6 INCHES

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-10

BUILDING 25900

ROOM 123B

PANEL "E"

10 19

EXISTING SUB PANEL "E"

208 / 120 V, 3 PHASE, SURFACE MOUNTED TOP FEED, 4 W 200A

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

1 20 Lights Room 122 2 1 20 Lights Room 121

1 20 Lights Room 122 4 1 20 Lights Corridor and &

1 20 Lights Room 122 6 1 20 Lights Rm 127

1 20

Adjustable Spotlight Rm 119, Ping Pong 8 1 20 Adjust Spot Rm. 123, 3rd Row VTR

1 20

Adjustable Spotlight Rm 119, Ping Pong 10 1 20 Adjust Spot Rm. 123, 2nd Row

1 20 Adjustable Spotlight

Rm 123, 6th Row 12 1 20 Adjust Spot Rm. 123, 1st Row

1 20 Adjustable Spotlight

Rm 123, 5th Row 14 1 20 Back of Servo Rack

1 20 Adjustable Spotlight

Rm 123, 4th Row 16 1 20 Recepts., Rm 119 &

17 1 20 Wall Coolers, Rm 119

North Wall 18 1 20 Recepts., Rm 119

19 1 20 Wall Coolers, Rm 119

North Wall 20 1 20 Recepts., Rm 119

1 20 Recept. Rm 123

South Wall 22 1 20 Recepts., Rm 123 West Wall

1 20 Recept. Rm 123 East Wall 24 1 20 Recepts., Rm 122

1 20 Recept. Rm 121 &

122 26 1 20 Wall Coolers #1 (123)

West Wall & East Wall (Servo)

1 20 Wall Coolers East

Wall Rm 123 28 2 20 Wall Coolers Rm 122 & 123 (Photo, SDS, and Control Rm)

1 20

Emergency Lights Relay Contacts 30 2 20 Lights, Rm 118

1 20 Lights Rm 119 32 1 20 Lights, Rm 117

33 1 20 Lights Rm 119 34 1 20 Lights, Rm 123, 3rd

Row

35 1 20 Lights Rm 123, 6th

Row 36 1 20 Lights, Rm 123, 2nd

Row (Computer)

37 1

Lights Rm 123, 5th Row (SP) 38 1 20

Lights Rm 123, 1st Row (Computer)

39 1 20 Lights Rm 123 7th

Row 40 1 20 Lights, Rm 123, 7th Row

41 1 20 Wall Coolers Rm 122

& 123, Eastwall 42 1 20 NO LABEL

RAFAEL ACOSTA

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

1) PANEL DIMENSIONS

LENGTH: 63 1/2 INCHES

WIDTH: 20 INCHES

DEPTH: 6 INCHES

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2018-EP-11

BUILDING 25900

ROOM 123B

PANEL "RM"

Cesar Limon

Cesar Limon

Vanessa Cuevas

Rafael Acosta

02/06/17

11 19

EXISTING SUB PANEL "RM"

208 / 120 V, 3 PHASE, SURFACE MOUNTED TOP FEED, 4 W 500A Main Breaker

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

3 100 R1 Panel 2 3 100 Computer Rm

3 100 " 4 3 100 "

3 100 " 6 3 100 "

3 175 R2 & R3 Panel 8 3 150 R5 Panel

3 175 " 10 3 150 "

3 175 " 12 3 150 "

3 60 Outside Switch 14 3 125 R6 Panel

3 60 " 16 3 125 "

17 3 60 " 18 3 125 "

1) PANEL DIMENSIONS

LENGTH: 48 INCHES

WIDTH: 38 INCHES

DEPTH: 11 INCHES

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-12

BUILDING 25900

ROOM 123C

PANEL "123C"

12 19

EXISTING SUB PANEL "123C"

208 / 120 V, 3 PHASE, SURFACE MOUNTED TOP FEED, 4 W 125A Main Breaker Bottom Feed

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

1 15 Spare 2 1 15 Strobe Lights

1 15 Lights on Work Table 4 1 15 Spare

1 15 Outlets on Work Table 6 3 15 Spare

1 15 ON S. Side Work

Table 8 3 15 Spare

3 30 220 V Outlet Bench 10 3 15 Spare

3 30 " 12 1 30 Spare

3 30 " 14 1 Blank

1 30 Spare 16 3 30 Spare

17 1 30 Spare 18 3 30 Spare

19 1 30 Spare 20 3 30 Spare

1 15 Spare 22 1 Blank

1 15 Spare 24 1 20 Blank

1 30 Spare 26 1 30 Spare

1 20 Spare 28 1 30 Spare

1 15 Spare 30 1 Blank

1 Blank 32 1 30 Spare

33 1 Blank 34 3 30 Spare

35 1 Blank 36 3 30

37 1 Blank 38 3 30

39 2 Blank 40 2 Blank

41 2 Blank 42 2 Blank

RAFAEL ACOSTA

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

1) PANEL DIMENSIONS

LENGTH: 81 INCHES

WIDTH: 16 INCHES

DEPTH: 6 INCHES

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-13

BUILDING 25900

ROOM 122

PANEL "R4"

13 19

EXISTING SUB PANEL "ROOM 122"

208 / 120 V, 3 PHASE, SURFACE MOUNTED TOP FEED, 4 W 125A MAIN BREAKER

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

1 30 Spare 2 3 30 Spares

1 30 Spare 4 3 30 Spares

1 30 Spare 6 3 30 Spares

3 20 Spare 8 3 30 Spares

3 20 Spare 10 3 30 Spares

3 20 Spare 12 3 30 Spares

2 15 Spare 14 2 15 Spares

2 15 Spare 16 2 15 Spares

17 2 20 Spare 18 1 20

Rm 119 (CSCMI Floor)

19 2 20 Spare 20 1 20

Rm 119 (CSCMI Console PWR)

1 20 Rm 119 (CSMI Floor) 22 1 20

Rm 119 (CSCMI Floor) UPS PWR (15

A UPS)

1 20 Spare 24 1 20 Rm 119 (CSCMI

Floor)

1 20 Spare 26 1 20

Rm 119 (CSCMI Floor) UPS PWR

(20A)

1 30 Spare 28 1

Blank

1 Blank 30 1 Blank

RAFAEL ACOSTA

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

1) PANEL DIMENSIONS

LENGTH: 38 1/2 INCHES

WIDTH: 16 1/2 INCHES

DEPTH: 5 INCHES

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-14

BUILDING 25900

ROOM 119

PANEL "R5"

14 19

EXISTING SUB PANEL "R5"

208 / 120 V, 3 PHASE, SURFACE MOUNTED TOP FEED, 4 W 225A MAIN LUGS

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

1 20 Outlet 2 VA 2 1 20 CSCMI Table Lights

2 20 FTRS-Far Corner and Side Outlets 4 1 20 CSCMI Table Recept.

South Side

2 20 " 6 2 30 CSCMI Table Recept.

1 20 North Table Recept 8 2 30 "

1 20 East Side Recept. 10 1 20 CSCMI Table Recept.

1 30 Spare 12 1 30 FTRS Lights

1 15 Outlet 30 A 14 1 Blanks

Blanks 16 1 Blanks

Blanks 18 1 Blanks

Blanks 20 1 Blanks

Blanks 22 1 Blanks

3 20 3 Phase Recept. (Not

Operational) 24 3 70

FTRS

OPO/Astrellalca Chiller

3 20 " 26 3 70 "

3 30 " 28 3 70

RAFAEL ACOSTA

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

1) PANEL DIMENSIONS

LENGTH: 52 INCHES

WIDTH: 24 INCHES

DEPTH: 6 INCHES

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-15

BUILDING 25900

ROOMS 105 & 106

PANEL "RG"

15 19

EXISTING SUB PANEL "RG" Right Side

(ROOM 105)

208 / 120 V, 3 PHASE, FLUSH MOUNTED TOP FEED, 4 W 225A Main Lugs

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

1 20 Lights Rm 114 2 1 20 Lights Rm 113

1 20 Lights Rm 115 4 1 20 Lights Rm 112

1 20 Lights Rm 117 6 1 20 Lights Rm 111

1 20 Lights Rm 109 8 1 20 Lights Rm 110

3 20 Lights Rm 108 10 1 20 Corridor Lights

3 20 Lights Rm 107 12 1 20 Lights Rm. 124, 125, & 126

3 20 Spare 14 1 20 Emergency Lights

1 20 Spare 16 1 20 Lights Rm 102

17 1 20 Lights Rm 101 & 103 18 1 20 Lights Rm 131

19 1 20 Lights Rm 105 20 1 20

North Outside Floodlight

1 20 Lights Rm 106 22 1 20

East, Outside Floodlight Added note on panel door “1 Light on NE corner of roof, above front door, pointed at parking area”

1 20

N. Outside Floodlight Note on circuit breakers “Flood

Lights Switches 23, 24, LEA

VE ON”

24 1 20

E. Outside Floodlight Note on circuit breakers “Flood

Lights Switches 23, 24, LEA

VE ON”

1 20

W. Outside Flood Light 26 1 30 Recept. RM 109 &

1 20 Recept. RM 104 &

105 28 1 20 Recept. RM 108 &

1 20 Recept. Rm 103 &

104 30 1 20 Recept. RM 107 &

1 20 Recept. Rm 106 &

128 32 1 20 Recept. RM 101 &

RAFAEL ACOSTA

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

1) PANEL DIMENSIONS

LENGTH: 41 1/2 INCHES

WIDTH: 21 INCHES

DEPTH: 5 INCHES

208 / 120 V, 3 PHASE, FLUSH MOUNTED TOP FEED, 4 W 225A Main Lugs

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

1 20

Recept. Room 109, (note: label is crossed-out)

34 1 20

Not legible (note1:

label is crossed-out)

(note2: breaker in ON position)

1 20 Recept. Room 112, 113 36 1 20 Door Controls Rm

1 20 Recept. Room 111, 112 38 1 20

Recept. Rm 114 & 11 5 (note: added label “Receptacle 113 (1 wall socket)”)

1 20

Recept. Room 110 and Xerox

(note: original label shows Recept Room

110)

40 1 20

Recept. Rm 114 (note:

both added label and label on circuit breaker show “TELETYPE

ONLY”)

1 20

Recept. Room 126 (note: added label “Refrigerator, Ki tchen”)

42 1 30

Recept. by Coke Machine

(note: added label “Room 115 Rece

pt. - Xerox, Coke”)

1 20

Recept. Room 126 (note: added label “Kitchen - Coffe e Pot”)

44 1 20 Recept. By Coke Machine

1 20 Recept. Room 125 &

126 46 1 20 Recept. By Coke

Machine (note: added label “Coke Machine”)

1 20

Recept. Room 117 (note: added label “Recept. 117, Da rk Room”)

48 1 20

Ex. Fan Rm 117 (note: added label “Exhaust Fan 117”)

49 1

Recept. Room 117 (note: label on circuit breaker “Dye Lab Outlets”)

50 1 20 Water Cooler

51 1 20 Recept. Room 131 52 1 20 Ex. Fan Rm 124, 125, and 126

1 20

Spare (note: breaker in ON position) 54 1 20

Spare (note: breaker in ON position)

1 20 Spare

(note: breaker in ON position)

56 1 20 Spare (note: breaker in ON position)

1 20 Spare

(note: breaker in ON position)

58 1 20

Spare (note1: label on breaker “Fire Alarm Circuit; Mass

Notification Circuit”) (note2: breaker locked in ON position)

1 20

Spare (note: breaker in ON position) 60 1 20 Mass Notification

Circuit

1 20 Sing. Phase Outlet

Rm. 117 62 3 Phase Outlet

1 20 Sing. Phase Outlet

Rm. 117 64 2 50 "

66 2 50

Xerox 2400 (note: label on breaker “Coke

Machine”)

68 2 50 "

EXISTING SUB PANEL "RG" Left Side

(ROOM 106)

1) PANEL DIMENSIONS

LENGTH: 41 1/2 INCHES

WIDTH: 21 INCHES

DEPTH: 5 INCHES

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

GENERAL NOTES

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-16

BUILDING 25900

ROOM 133

PANEL "H"

16 19

EXISTING SUB PANEL "H"

480 / 277 V, 3 PHASE, SURFACE MOUNTED TOP FEED, 3 W 600 A MAIN LUGS

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

3 15 Boiler Control 2 3 15 Control Circuit

Transformer

3 15 " 4 3 15 "

3 15 " 6 3 15 "

3 15 #2 Boiler Feeder

Pump #52 8 3 30 #1 Boiler Feeder Pump #52

3 15 " 10 3 30 "

3 15 " 12 3 30 "

3 20 Chilled Water Pump

#55 14 3 30 7" Compressor Brown

3 20 " 16 3 30 "

17 3 20 " 18 3 30 "

19 3 40 Cooling tower #54 20 3 70 Air Handler East Unit

3 40 " 22 3 70 "

3 40 " 24 3 70 "

3 70

Air Handler North Heating 26

3 70 " 28

3 70 " 30

3 400 Chiller 32

3 400 " 34

3 400 " 36

1 15 Spare

RAFAEL ACOSTA

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

1) PANEL DIMENSIONS

LENGTH: 57 INCHES

WIDTH: 38 INCHES

DEPTH: 10 12" INCHES

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-17

BUILDING 25900

ROOM 133

PANEL "D"

17 19

EXISTING SUB PANEL "D"

208 / 120 V, 3 PHASE, SURFACE MOUNTED TOP FEED, 3 W 225 A MAIN LUGS

CKT. NO. POLES TRIP (AMPS) SERVICES A B C CKT. NO. POLES TRIP (AMPS) SERVICES

1 20 No Label 2 1 20 No Label

1 20 No Label 4 1 20 No Label

1 20 No Label 6 1 20 No Label

1 20

No Label (note: note on wall next to panel “Air Conditioning”)

8 1 20 No Label

1 20 Green Compressor 10 1 20 No Label

1 20

No Label (note: note on wall next to panel “Mach Shop Supply”)

12 1 20 No Label

2 30 Air Compressor 14 1 20 No Label

2 30 " 16 1 20 No Label

17 1 20 No Label 18 1 20 No Label

19 1 20 No Label 20 1 20 No Label

1 20 No Label 22 1 20 No Label

3 40 No Label 24 1 20 No Label

3 40 " 26 1 20 No Label

3 40 " 28 1 20 No Label

RAFAEL ACOSTA

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

1) PANEL DIMENSIONS

LENGTH: 43 INCHES

WIDTH: 6 1/2 INCHES

DEPTH: 20 12" INCHES

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-18

RAFAEL ACOSTA

18 19

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

GENERAL NOTES

INSTALLATION:

1) COMPLY WITH NFPA 70 NATIONAL FIRE PROTECTION ASSOCIATION, NATIONAL ELECTRIC CODE

2017 AND IEEE C2 NATIONAL ELECTRICAL SAFETY CODE.

2) AIR HANDLER AND HEAT PUMP TO BE ON CIRCUITS WITH HACR TYPE BREAKERS.

3) ALL CONDUCTOR WIRE SHALL BE THHN, 600 V, STRANDED, AND MADE OF COPPER FOR SPLICING AND

INCLUDES NEUTRALS AND GROUNDS.

INSTALLATION OF ELECTRICAL EQUIPMENT INCLUDES:

1. LEVELING AND GROUTING CHANNEL BASES.

DRILLING HOLES, FURNISHING HARDWARE, AND ASSEMBLING COMPONENTS TO EACH

OTHER.

2. FURNISHING MATERIALS FOR AND MAKING ALL CONNECTIONS CORRECTLY IN

ACCORDANCE WITH PANEL SCHEDULES THAT ARE PROVIDED.

3. LABELING WIRES AND TAGGING WIRES AND CABLES AT EACH END.

GROUT ELECTRICAL EQUIPMENT INSTALLED ON CONCRETE FOUNDATIONS IN PLACE TO

PROVIDE FULL AND EVEN BEARING. REPAIR DAMAGED PAINTED SURFACES OF EQUIPMENT TO

MATCH ORIGINAL FINISH. GOVERNMENT WILL INSPECT EQUIPMENT DURING CONSTRUCTION.

CONDUCTOR MARKERS:

· WHITE

· SELF-LAMINATING VINYL TYPE OR HEAT SHRINK TYPE.

· MARKED WITH CONDUCTOR DESIGNATION.

· COMPUTER GENERATED LETTERING.

(CONTINUED ON SHEET 19)

GENERAL NOTES:

CONTRACTOR SHALL VERIFY AND LABEL EACH CONDUCTOR SHOWN IN DRAWINGS OF THE EXISTING

PANELS PRIOR TO REMOVING. THE EXISTING CONDUCTORS INCLUDING FEEDERS SHALL NOT BE

REMOVED BUT TRANSFERRED TO THE NEW PANEL AND TERMINATED TO THE CORRECT BREAKER SIZE.

EXISTING GROUND WIRES SHALL BE REMOVED FROM EACH OF THE 17-PANELS.

NEW GROUND COPPER WIRE WITH ASSOCIATED GROUNDING HARDWARE SHALL BE INSTALLED AND

TERMINATED TO EXISTING GROUND RODS. EACH PANEL AND SUBPANEL WILL HAVE A MAIN BREAKER

ALONG WITH ALL THE BREAKERS FOR EACH BRANCH CIRCUIT THAT FOLLOWS THE NEC SIZING RULES IN

SECTIONS 210-22 (C), 220-3(A), 220-10(A), AND 384-16(C), BOLT ON BREAKERS, AND COPPER BUS.

IF THE EXISTING CONDUCTOR IS TOO SHORT FOR NEW PANELS, CONTRACTOR SHALL ADD TO THAT

CONDUCTOR BY SPLICING THE SAME SIZE OF CONDUCTOR.

IF THE EXISTING CONDUIT IS TOO SHORT FOR NEW PANELS, CONTRACTOR SHALL ADD GALVANIZED RIGID

CONDUIT LABEL CIRCUITS IN THE NEW PANEL TO THE DEVICE IT GOES TO. ONCE EACH PANEL IS

INSTALLED INDIVIDUALLY THE CONTRACTOR SHALL TEST EACH BREAKER IS

WORKING CORRECTLY. ALL NEW PANELS

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

1 08/28/2019 REVISED GENERAL NOTE4 AS INDICATED IN CLOUD. CML

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

DRAWING TITLE

WS-25900-2019-EP-19

GENERAL NOTES

RAFAEL ACOSTA

19 19

CESAR M. LIMON

VANESSA CUEVAS

CESAR M. LIMON

1) IDENTIFICATION OF CONDUCTORS SHALL BE DONE AS STATED IN

NFPA 79 ELECTRICAL STANDARD FOR INDUSTRIAL MACHINERY

SECTION 13.2. OVERCURRENT PROTECTION

SIZING . FEEDER OVERCURRENT DEVICES MUST HAVE A RATING OF

NOT LESS THAN 125 PERCENT OF THE CONTINUOUS LOADS, PLUS 100

PERCENT OF THE NON-CONTINUOUS LOADS.

2) EACH PANEL SHALL HAVE THE PROPER MARKING AND SAFETY SIGNS

AS STATED ON NFPA 79 SECTION 16.2 SAFETY SIGNS FOR ELECTRICAL

ENCLOSURES. PANEL SHALL DISPLACE OUTSIDE LABELS ON THE

DOOR OF THE PANEL WITH THE VOLTAGE 208 / 120 V WYE AND 480 V

DELTA, DANGER, AND IN THE PANEL DOOR TO LIST THE CIRCUIT

DESIGNATIONS.

CONDUIT:

A) FITTINGS REQUIRED TO COMPLETE ELECTRICAL CONDUIT SYSTEMS.

INCLUDES CAPS, CONNECTORS, COUPLINGS (EXCLUDING

EXPANSION AND EXPANSION-DEFLECTION COUPLINGS), NIPPLES,

REDUCERS, ELBOWS, PIPE, PLUGS LOCKNUTS, BOND NUTS,

BUSHINGS, SEALS (EXCLUDING WALL PENETRATION AND ANY

OTHER FITTINGS.)

B) DEVICES REQUIRED TO COMPLETE ELECTRICAL CONDUIT SYSTEMS

AND TO FASTEN, CLAMP, ATTACH, AND SUPPORT EACH CONDUIT IN

PLACE.

1) INCLUDES THREADED JOINT COMPOUND; PROTECTIVE SEALANT;

MATERIALS FOR SEALING ENDS OF CONDUITS TERMINATING AT

OUTDOOR BOXES, PANEL BOARDS OR CABINETS; SUPPORTS AND

CLAMPS.

2) COMPLETE WITH BOLTS, WASHERS, AND NUTS.

A) JUNCTION BOX, JUNCTION BOX EXTENSIONS, AND JUNCTION BOX

COVERS: STEEL, OR ZINC COATED.

B) EXPANSION COUPLINGS:

1) FURNISH FOR LONGITUDINAL MOVEMENT ONLY.

GENERAL NOTES:

I

S

S

U

E

D

T

O

C

O

N

S

T

R

U

C

T

I

O

N

ARCH D

A. EXPANSION-DEFLECTION COUPLINGS:

1. FURNISH FOR MOVEMENT IN ANY DIRECTION.

2. WATERTIGHT.

3. DEFLECTION AND EXPANSION: 3/4-INCH, MINIMUM.

4. ANGULAR MISALIGNMENT: 30 DEGREES, MINIMUM.

F. CONDUIT WALL/FLOOR PENETRATION SEALS:

1. ELASTOMERIC MATERIAL TO PREVENT LIQUID OR LIQUID AND GAS SEEPAGE.

2. DUST TIGHT.

3. FIRE RETARDANT.

H. REMOVE BURRS AND SHARP CORNERS AT ENDS OF METAL CONDUIT.

I. SEAL ENDS OF CONDUITS THAT TERMINATE AT BOXES, OR CABINETS WITH SEALING MATERIAL OR SEALING BUSHINGS TO PREVENT AIR CIRCULATION THROUGH CONDUITS INTO BOXES, CABINETS. INSTALL SEALS

IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.

J. TIGHTEN CONDUIT TO ELECTRICAL EQUIPMENT MOUNTED ON TUBULAR METAL STRUCTURES SECURELY AND SUPPORT RIGIDLY IN PLACE BY CONDUIT CLAMPS, HEX HEAD NUTS, AND THREADED 3/8-INCH STUD

FASTENERS DRIVEN BY POWER-ACTUATED TOOLS.

K. INSTALL EXPANSION COUPLINGS WHERE EXPOSED OR EMBEDDED CONDUITS CROSS EXPANSION OR CONTRACTION JOINTS. INSTALL EXPANSION COUPLINGS AND EXPANSION AND EXPANSION-DEFELECTION COUPLINGS

IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.

L. DRILL HOLES AS NEEDED IN CONCRETE FOR INSTALLATION OF CONDUIT THRU WALLS, FLOOR, OR CEILING. GROUT

CONDUIT IN PLACE IN ACCORDANCE NO SHRINK GROUT.

CONTRACTOR SHALL SUBMIT APPROVAL DATA (MANUFACTURER'S PRODUCT DATA) AND INSTRUCTIONS

(MANUFACTURER'S SURFACE PREPARATION, MIXING, INSTALLATION, AND

CURING INSTRUCTIONS).

GENERAL NOTES:

CHECK THAT ALL THREE PHASES ARE CORRECT (A, B, AND C). THE METER READING ON THE PHASING

TESTER SHOULD READ ZERO BETWEEN PHASE 1 AND PHASE A. THE CONTRACTOR'S CQC SHALL VERIFY

WITH CONTRACTOR THAT EACH CIRCUIT THAT POWERS THAT PIECE OF EQUIPMENT TURNS ON AND WILL

RUN WITHOUT TRIPPING THE CIRCUIT BREAKER.

REPAIRS FOR WALLS AND SURFACES:

ANY SCRATCHES OR HOLES SHALL BE FILLED AND PAINTED TO MATCH

THE EXISTING WALL OR FLOOR COLOR.

Sheets and Views
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-COVER SHEET
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Staging Area
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-BUILDING 25900 LAYOUT
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Panel A1
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Panel A2
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Panel MECH. ROOM
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Room 129
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Panel 123B
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Room F
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Panel E
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Panel RM
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Panel 123C
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Panel 122
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Panel R5
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Panel RG (Right and Left Sides)
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Panel H
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-Panel D
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-RODENT DROPPING REMEDIATION (3)
ARL047479P- PLANS AND DRAWINGS - 28 AUGUST 2019 -final Design Upgrade of Panels for Building 25900 AMRAD-RODENT DROPPING REMEDIATION (4)