APPENDIX B ROOFER DATA .pdf
PDF 12 MB Posted
- Attached to
- WSMR ROOFING PROJECTS Federal contract opportunity
- Solicitation number
- W911SG19B0004
About this file
APPENDIX B ROOFER DATA
View the file
Other files for this federal contract opportunity
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Appendix B
ROOFER Data
Building:
Last Replacement:Occupancy:
01403 - GAS STATION W/ BLDG
5/11/1995WSMR
Sec Name:
Original Construction: 1/1/1958Area:
A
912 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
0 (LF) 121 (LF)
0 (LF) 0 (LF)
0 (LF)
0 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Bar Joists/Bearing Wall
CONCRETE STD: Cast-In-Place
1/4 in 12
ROOF EDGE
NONE
Structure:
Roof Category: Membrane
ROOF EDGE: Embedded Edge Metal
AGG: Pea Gravel
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
4-PLY
Spec. No.:
NONE
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=5-10
Base Flashing:
Counterflashing:
Membrane Mfg: UNKNOWN
UNKNOWN
Comments:
Thickness:
WOOD FIBERBOARD, POLYISOCYANURATE
Tapered:2Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
2.00 (IN)
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
White Sands Missile Range (35995) Unassigned
Page 1 of 4June 15, 2016
01403 - GAS STATION W/ BLDG
5/11/1995WSMR
Sec Name:
Original Construction: 1/1/1958Area:
B
330 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
0 (LF) 61 (LF)
0 (LF) 0 (LF)
24 (LF)
0 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Bar Joists/Bearing Wall
CONCRETE STD: Cast-In-Place
1/4 in 12
ROOF EDGE
NONE
Structure:
Roof Category: Membrane
WALL/PARAPET, ROOF EDGE: Embedded Edge Metal, PLUMBING VENT
AGG: Marble Chip
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
4-PLY
Spec. No.:
MOD BIT: Granule Surface
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=5-10
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg: UNKNOWN
UNKNOWN
Comments:
Thickness:
WOOD FIBERBOARD, POLYISOCYANURATE
Tapered:2Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
2.00 (IN)
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 2 of 4June 15, 2016
01403 - GAS STATION W/ BLDG
1/1/1979WSMR
Sec Name:
Original Construction: 1/1/1958Area:
C
72 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
0 (LF) 36 (LF)
0 (LF) 0 (LF)
0 (LF)
0 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Long Sp Deck, Beams
STEEL
1/8 in 12
ROOF EDGE
NONE
Structure:
Roof Category: Membrane
ROOF EDGE: Embedded Edge Metal
AGG: Marble Chip
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
3-PLY
Spec. No.:
NONE
Reinforcement:
Type:
B.U.(HOT/COLD): Organic Felt
No
Surfacing:
This roof section is a canopy for gas the gas pumps.
ERSL = 0
Base Flashing:
Counterflashing:
Membrane Mfg: UNKNOWN
UNKNOWN
Comments:
Thickness:
0.00
NONE
Tapered:0Layers:
Types:
Attachment:
R-Value:
0.00 (IN)
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 3 of 4June 15, 2016
B u ild in g F ac il it y
C la ss S e c
N a m e
In su la ti o n
T y p e( s
R o o fi n g
T y p e
A re a
S F
S lo p e D e c k T yp e
G A
S S
T A
T
IO
N W
/ B
LD
G S up pl y
A
B U
R : A sp ha lt W
O O
D F
IB
E
R B
O A
R D
P
O
LY
IS
O
C Y
A N
U R
A T
E C
O N
C R
E T
E S
T D
: C as t- In
-P la ce
1/
B B
U R
: A sp ha lt
W O
O D
F
IB
E R
B O
A R
D
P O
LY
IS
O C
Y A
N U
R A
T E
C O
N C
R E
T E
S T
D : C as t-
In -P la ce
1/
C
B U
R : A sp ha lt N
O N
E
S T
E E
L
1/
W hi te S an ds
M is si le
R an ge
5)
R o o f
S e ct io n L is t
R ep o rt
U na ss ig n e d
T o ta ls
B u il d in g s
S e ct io n s
A re a
1, S F
P a ge o f
Ju n e
, 2
D I S T R E S S
S E V E R I T Y
D E F E C T
Q U A N T I T Y
N U M B E R
Building:
Section:
01403 - GAS STATION W/ BLDG
A
Perimeter Flashing:
Curb Flashing:
121 (LF)
0 (LF)Inspection Date: 4/18/2011
Roof Type: Built-Up
Key Plan
Thru Panel Fasteners:
Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP) Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV) Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD) Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)
1 EM L 1 121
2 EM M 1 14
3 SR M 1 80
Roof Section Inspection Worksheet History
Page 1 of 3June 15, 2016
S T R E S S
S E V E R I T Y
D E F E C T
Q U A N T I T Y
N U M B E R
Building:
Section:
01403 - GAS STATION W/ BLDG
B
Perimeter Flashing:
Curb Flashing:
85 (LF)
0 (LF)Inspection Date: 4/18/2011
Roof Type: Built-Up
Key Plan
Thru Panel Fasteners:
Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP) Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV) Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD) Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)
1 EM L 1 57
2 EM M 1 6
3 SR M 1 20
Roof Section Inspection Worksheet History
Page 2 of 3June 15, 2016
S T R E S S
S E V E R I T Y
D E F E C T
Q U A N T I T Y
N U M B E R
Building:
Section:
01403 - GAS STATION W/ BLDG
C
Perimeter Flashing:
Curb Flashing:
36 (LF)
0 (LF)Inspection Date: 4/18/2011
Roof Type: Built-Up
Key Plan
Thru Panel Fasteners:
Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP) Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV) Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD) Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)
1 HL H 1 72
2 EM L 1 36
3 EM M 1 4
Roof Section Inspection Worksheet History
Page 3 of 3June 15, 2016
Building
Facility Class
Sec Name - Slope - Membrane Last Cons Year
Last Insp Year
Area
(SF)
RCIInsulation Type(s)
Deck Type
MCI-FCI-ICI
01403 - GAS STATION W/ BLDG
Supply
A - 1/4 - BUR: Asphalt 1995 2011912 79
POLYISOCYANURATE, WOOD FIBERBOARD
CONCRETE STD: Cast-In-Place
82/74/---
B - 1/4 - BUR: Asphalt 1995 2011330 82
POLYISOCYANURATE, WOOD FIBERBOARD
CONCRETE STD: Cast-In-Place
84/77/---
C - 1/8 - BUR: Asphalt 1979 201172 22
NONE
STEEL
0/74/---
White Sands Missile Range (35995)
Roof Section RCI Report
Unassigned
Totals: Buildings = 1 Sections = 3 Area = 1,314
Page 1 of 2June 15, 2016
01407 - ELECTRON EQUIPMENT FACILITY
1/1/1991WSMR
Sec Name:
Original Construction: 1/1/1987Area:
A
13,691 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
402 (LF) 0 (LF)
0 (LF) 0 (LF)
120 (LF)
0 (LF)
Access: INTERNAL LADDER: Permanent
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Bar Joists/Bearing Wall
STEEL
1/4 in 12
INTERIOR DRAINS, SCUPPERS
NONE
Structure:
Roof Category: Membrane
EQUIPMENT SUPPORT: Curbs, ROOF PENETRATION, PLUMBING VENT, WALL/PARAPET
AGG: River Gravel
Description:
Protected Mem.:
Attachment:
METAL
ASPHALT PLANK
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
4-PLY
Spec. No.:
MINERAL SURF: Glass
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=7-10
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg: UNKNOWN
UNKNOWN
Comments:
Thickness:
15.00
PERLITE, POLYISOCYANURATE
Tapered:2Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
3.00 (IN)
Membrane:
Insulation:
Yes
Flashing:
Roof Section Inventory Report
Page 1 of 8September 28, 2016
01407 - ELECTRON EQUIPMENT FACILITY
1/1/1991WSMR
Sec Name:
Original Construction: 1/1/1987Area:
B
570 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
96 (LF) 0 (LF)
0 (LF) 0 (LF)
0 (LF)
0 (LF)
Access: EXTERNAL LADDER: Permanent
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Bar Joists/Bearing Wall
STEEL
1/4 in 12
SCUPPERS
NONE
Structure:
Roof Category: Membrane
WALL/PARAPET, ROOF PENETRATION
AGG: River Gravel
Description:
Protected Mem.:
Attachment:
METAL
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
Spec. No.:
MINERAL SURF: Glass
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=10+
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg: UNKNOWN
UNKNOWN
Comments:
Thickness:
12.00
POLYISOCYANURATE, PERLITE
Tapered:2Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
3.00 (IN)
Membrane:
Insulation:
Yes
Flashing:
Roof Section Inventory Report
Page 2 of 8September 28, 2016
01407 - ELECTRON EQUIPMENT FACILITY
1/1/1991WSMR
Sec Name:
Original Construction: 1/1/1987Area:
C
1,205 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
140 (LF) 0 (LF)
0 (LF) 0 (LF)
0 (LF)
0 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Bar Joists/Bearing Wall
STEEL
1/4 in 12
SCUPPERS
NONE
Structure:
Roof Category: Membrane
WALL/PARAPET, PITCH PAN, EQUIPMENT SUPPORT: Curbs, PLUMBING VENT, ROOF PENETRATION
AGG: River Gravel
Description:
Protected Mem.:
Attachment:
METAL
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
Spec. No.:
MINERAL SURF: Glass
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=10+
BOILER STACK CORRODED IN HALF, LAYING ON ROOF.
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg: UNKNOWN
UNKNOWN
Comments:
Thickness:
12.00
PERLITE, POLYISOCYANURATE
Tapered:2Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
3.00 (IN)
Membrane:
Insulation:
Yes
Flashing:
Roof Section Inventory Report
Page 3 of 8September 28, 2016
01407 - ELECTRON EQUIPMENT FACILITY
1/1/1991WSMR
Sec Name:
Original Construction: 1/1/1987Area:
D
180 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
63 (LF) 0 (LF)
0 (LF) 0 (LF)
0 (LF)
0 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Bar Joists/Bearing Wall
STEEL
1/4 in 12
SCUPPERS
NONE
Structure:
Roof Category: Membrane
WALL/PARAPET
AGG: River Gravel
Description:
Protected Mem.:
Attachment:
METAL
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
Spec. No.:
MINERAL SURF: Glass
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=10+
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg: UNKNOWN
UNKNOWN
Comments:
Thickness:
12.00
POLYISOCYANURATE, PERLITE
Tapered:2Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
3.00 (IN)
Membrane:
Insulation:
Yes
Flashing:
Roof Section Inventory Report
Page 4 of 8September 28, 2016
01407 - ELECTRON EQUIPMENT FACILITY
1/1/1991WSMR
Sec Name:
Original Construction: 1/1/1987Area:
E
912 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
244 (LF) 0 (LF)
0 (LF) 0 (LF)
0 (LF)
0 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Bar Joists/Bearing Wall
STEEL
1/4 in 12
SCUPPERS
NONE
Structure:
Roof Category: Membrane
WALL/PARAPET, EQUIPMENT SUPPORT: None (unflashed), EQUIPMENT SUPPORT: Wood Sleepers
AGG: River Gravel
Description:
Protected Mem.:
Attachment:
METAL
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
Spec. No.:
MINERAL SURF: Glass
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=10+
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg: UNKNOWN
UNKNOWN
Comments:
Thickness:
12.00
PERLITE, POLYISOCYANURATE
Tapered:2Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
3.00 (IN)
Membrane:
Insulation:
Yes
Flashing:
Roof Section Inventory Report
Page 5 of 8September 28, 2016
01407 - ELECTRON EQUIPMENT FACILITY
1/1/1995
Sec Name:
Original Construction:Area:
F
940 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
28 (LF) 80 (LF) 105 (LF)
Access: INTERNAL LADDER: Permanent
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
UNKNOWN
CONCRETE STD: Cast-In-Place
1/8 in 12
INTERIOR DRAINS
NONE
Structure:
Roof Category: Membrane
ROOF EDGE: Embedded Edge Metal, WALL/PARAPET
ELASTOMERIC
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
LIQUID APP: Type Unknown
Spec. No.:
NONE
Reinforcement:
Type:
MOD BIT/1-PLY: Reinforcement Unknown
No
Surfacing:
ERSL W/=10+
ERSL W/O=3-5
HYDROSTOP OVER CONCRETE. NEEDS RECOAT.
Base Flashing:
Counterflashing:
Membrane Mfg:
Comments:
Thickness:
NONE
Tapered:Layers:
Types:
Attachment:
R-Value:
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 6 of 8September 28, 2016
01407 - ELECTRON EQUIPMENT FACILITY
1/1/1991WSMR
Sec Name:
Original Construction: 1/1/1987Area:
G
239 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
71 (LF) 0 (LF)
0 (LF) 0 (LF)
0 (LF)
0 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Long Sp Deck, Beams
CONCRETE LWT: Cast-In-Place
1/4 in 12
SCUPPERS
NONE
Structure:
Roof Category: Membrane
WALL/PARAPET
AGG: River Gravel
Description:
Protected Mem.:
Attachment:
METAL
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
Spec. No.:
MINERAL SURF: Glass
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=10+
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg: UNKNOWN
UNKNOWN
Comments:
Thickness:
12.00
POLYISOCYANURATE, PERLITE
Tapered:2Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
3.00 (IN)
Membrane:
Insulation:
Yes
Flashing:
Roof Section Inventory Report
Page 7 of 8September 28, 2016
Roof Section Inventory Report
Selection Criteria
Sort Criteria
Section Name Last Replacement Built Date Deck Type Roof Slope Section Area Membrane Attachment Facility Class Insulation Type Roof Type
All All All All All All All All All All
Section Name - Ascending
Page 8 of 8September 28, 2016
01409 - DATA SCIENCE INFO FACILITY
3/7/1995
Sec Name:
Original Construction:Area:
A
6,750 (SF)
Layout:
Access:
Structural Frame:
Roof Deck:
Drainage:
Slope:
Structure:
Roof Category: Metal Panel
Metal Roof Type:
Attachment Surface:
Panel Attachment:
Roof Overlaid:
Flashing Types:
Panel Type:
Accessories:
Layers:
Underlayment:
Misc.
METAL PANEL - STANDING SEAM - SEPARATE CAP Snap-on
Covering & Flashing:
SLOPE = 1
ERSL = 10+
Comments:
Base Metal:
Panel Finish:
NO
Roof Section Inventory Report
Page 1 of 2September 29, 2016
Selection Criteria
Sort Criteria
Section Name Last Replacement Built Date Deck Type Roof Slope Section Area Membrane Attachment Facility Class Insulation Type Roof Type
All All All All All All All All All All
Page 2 of 2September 29, 2016
01523 - UNTERUP SYS FAC
6/2/1990
Sec Name:
Original Construction:Area:
A
412 (SF)
Layout:
Access:
Structural Frame:
Roof Deck:
Drainage:
Slope: 3 in 12
Structure:
Roof Category: Metal Panel
Metal Roof Type:
Attachment Surface:
Panel Attachment:
Roof Overlaid:
Flashing Types:
Panel Type:
Accessories:
Layers:
Underlayment:
Misc.
METAL PANEL - STANDING SEAM - SEPARATE CAP Snap-on
Covering & Flashing:
ERSL=10+
Comments:
Base Metal:
Panel Finish:
NO
Roof Section Inventory Report
Selection Criteria
Sort Criteria
Section Name Last Replacement Built Date Deck Type Roof Slope Section Area Membrane Attachment Facility Class Insulation Type Roof Type
All All All All All All All All All All
01527 - UNTERUP SYS FAC
3/8/1970
Sec Name:
Original Construction:Area:
A
480 (SF)
Layout:
Access:
Structural Frame:
Roof Deck:
Drainage:
Slope: 2 in 12
Structure:
Roof Category: Metal Panel
Metal Roof Type:
Attachment Surface:
Panel Attachment:
Roof Overlaid:
Flashing Types:
Panel Type:
Accessories:
Layers:
Underlayment:
Misc.
METAL PANEL - STANDING SEAM - SEPARATE CAP Snap-on
Covering & Flashing:
ERSL = 10+
Comments:
Base Metal:
Panel Finish:
NO
Roof Section Inventory Report
Selection Criteria
Sort Criteria
Section Name Last Replacement Built Date Deck Type Roof Slope Section Area Membrane Attachment Facility Class Insulation Type Roof Type
All All All All All All All All All All
01544 - HISTORIC GM FACILITY
4/26/2010WSMR
Sec Name:
Original Construction: 1/1/1954Area:
B
11,529 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
0 (LF) 492 (LF)
0 (LF) 378 (LF)
0 (LF)
0 (LF)
Access: EXTERNAL LADDER: Permanent
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
UNKNOWN
GYPSUM: Precast
1/4 in 12
GUTTERS & DOWNSPOUTS
LAMINATED ASPHALT/KRAFT
Structure:
Roof Category: Membrane
AREA DIVIDER, ROOF EDGE: Embedded Edge Metal
AGG: Pea Gravel
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
Spec. No.:
MOD BIT: Granule Surface
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=10+
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg:
UNKNOWN
Comments:
Thickness:
15.00
WOOD FIBERBOARD, EXPANDED POLYSTYRENE
Tapered:2Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
4.00 (IN)
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 2 of 10May 16, 2016
01544 - HISTORIC GM FACILITY
4/26/2010WSMR
Sec Name:
Original Construction: 1/1/1954Area:
C
5,582 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
0 (LF) 244 (LF)
0 (LF) 244 (LF)
183 (LF)
0 (LF)
Access: EXTERNAL LADDER: Permanent
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
UNKNOWN
GYPSUM: Precast
1/4 in 12
GUTTERS & DOWNSPOUTS
LAMINATED ASPHALT/KRAFT
Structure:
Roof Category: Membrane
EQUIPMENT SUPPORT: Wood Sleepers, EQUIPMENT SUPPORT: Structural Frame, ROOF PENETRATION, PLUMBING VENT, EQUIPMENT SUPPORT: Curbs, WALL/PARAPET, AREA DIVIDER, PITCH PAN, ROOF EDGE: Embedded Edge Metal
AGG: Pea Gravel
Description:
Protected Mem.:
Attachment:
METAL
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
Spec. No.:
MOD BIT: Granule Surface
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=10+
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg:
UNKNOWN
Comments:
Thickness:
15.00
WOOD FIBERBOARD, EXPANDED POLYSTYRENE
Tapered:2Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
4.00 (IN)
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 3 of 10May 16, 2016 ild in g F ac il it y
C la ss S e c
N a m e
In su la ti o n
T y p e( s
R o o fi n g
T y p e
A re a
S F
S lo p e D e c k T yp e
H
IS
T O
R
IC
G M
F A
C
IL
IT
Y
R es ea rc h, D e ve lo pm en t, T e st an d
E va lu at io n
,8
A B
U R
: A sp ha lt
W O
O D
F
IB
E R
B O
A R
D , E
X P
A N
D E
D P
O
LY
S T
Y R
E N
E G
Y P
S U
M
P re ca st
1/
,5
B B
U R
: A sp ha lt
W O
O D
F
IB
E R
B O
A R
D , E
X P
A N
D E
D P
O
LY
S T
Y R
E N
E G
Y P
S U
M
P re ca st
1/
5, C
B U
R : A sp ha lt W
O O
D F
IB
E
R B
O A
R D
, E X
P A
N D
E D
P O
LY
S
T Y
R E
N E
G Y
P S
U M
P re ca st
1/
2, D
B U
R : A sp ha lt W
O O
D F
IB
E
R B
O A
R D
, E X
P A
N D
E D
P O
LY
S
T Y
R E
N E
G Y
P S
U M
P re ca st
1/
2, E
B U
R : A sp ha lt E
X P
A N
D E
D P
O L
Y S
T Y
R E
N E
W
O O
D F
IB
E
R B
O A
R D
G Y
P S
U M
P re ca st
1/
2, F
B U
R : A sp ha lt E
X P
A N
D E
D P
O L
Y S
T Y
R E
N E
W
O O
D F
IB
E
R B
O A
R D
G Y
P S
U M
P re ca st
1/
2, G
B U
R : A sp h a lt
E X
P A
N D
E D
P O
L Y
S T
Y R
E N
E
W O
O D
F
IB
E R
B O
A R
D G
Y P
S U
M
P re ca st
1/
2, H
B U
R : A sp ha lt E
X P
A N
D E
D P
O L
Y S
T Y
R E
N E
W
O O
D F
IB
E
R B
O A
R D
G Y
P S
U M
P re ca st
1/
2, I
B U
R
A sp ha lt
E X
P A
N D
E D
P O
LY
S
T Y
R E
N E
, W O
O D
F
IB
E R
B O
A R
D G
Y P
S U
M
P re ca st
1/
W hi te S an ds
M is si le
R an ge
5)
R o o f
S e ct io n L is t
R ep o rt
U na ss ig n e d
T o ta ls
B u il d in g s
S e ct io n s
A re a
,8
(S F
P a ge o f
M a y
, 2
B B
U R
: A sp ha lt
B B
U R
: A sp ha lt
W O
O D
F
IB
E R
B O
A R
D , E
X P
A N
D E
D
,5
P
O
LY
S T
Y R
E N
E G
Y P
S U
M
P re ca st
C B
U R
: A sp ha lt
C B
U R
: A sp ha lt
W O
O D
F
IB
E R
B O
A R
D , E
X P
A N
D E
D 5, P O
LY
S
T Y
R E
N E
G Y
P S
U M
P re ca st
S T R E S S
S E V E R I T Y
D E F E C T
Q U A N T I T Y
N U M B E R
Building:
Section:
01544 - HISTORIC GM FACILITY
B
Perimeter Flashing:
Curb Flashing:
870 (LF)
0 (LF)Inspection Date: 1/25/2011
Roof Type: Built-Up
Key Plan
Thru Panel Fasteners:
Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP) Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV) Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD) Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)
1 EM L 1 492
2 EM M 1 49
3 SR M 1 225
4 SR H 1 23
Roof Section Inspection Worksheet History
Page 2 of 9May 16, 2016
S T R E S S
S E V E R I T Y
D E F E C T
Q U A N T I T Y
N U M B E R
Building:
Section:
01544 - HISTORIC GM FACILITY
C
Perimeter Flashing:
Curb Flashing:
671 (LF)
36 (LF)Inspection Date: 1/25/2011
Roof Type: Built-Up
Key Plan
Thru Panel Fasteners:
Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP) Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV) Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD) Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)
1 EM L 1 244
2 EM M 1 24
3 SR M 1 155
4 SR H 1 5
5 FP H 4 9
6 DV M 1 3
7 PP H 4 9
8 PP L 1 10
9 BF H 2 1
Roof Section Inspection Worksheet History
Page 3 of 9May 16, 2016
Sec Name - Slope - Membrane Last Cons Year
Last Insp Year
Area
(SF)
RCIInsulation Type(s)
Deck Type
MCI-FCI-ICI
01544 - HISTORIC GM FACILITY
Research, Development, Test, and Evaluation
A - 1/4 - BUR: Asphalt 2010 201112,891 81
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Precast
82/77/---
B - 1/4 - BUR: Asphalt 2010 201111,529 82
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Precast
85/78/---
C - 1/4 - BUR: Asphalt 2010 20115,582 80
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Precast
86/75/---
D - 1/4 - BUR: Asphalt 2010 20112,327 86
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Precast
82/88/---
E - 1/4 - BUR: Asphalt 2010 20112,730 88
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Precast
86/87/---
F - 1/4 - BUR: Asphalt 2010 20112,327 86
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Precast
82/88/---
G - 1/4 - BUR: Asphalt 2010 20112,366 90
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Precast
100/85/---
H - 1/4 - BUR: Asphalt 2010 20112,776 88
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Precast
88/86/---
I - 1/4 - BUR: Asphalt 2010 20112,366 93
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Precast
90/100/---
White Sands Missile Range (35995)
Roof Section RCI Report
Unassigned
Totals: Buildings = 1 Sections = 9 Area = 44,894
Page 1 of 2May 16, 2016
B - 1/4 - BUR: Asphalt 11,529 2010 20112010 2011 85/78/--- 82
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Precast
C - 1/4 - BUR: Asphalt 5,582 2010 20112010 2011 80
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Precast
SECTION "B"
SECTION "C"
01547 - CHEMISTRY LAB
3/8/1980
Sec Name:
Original Construction:Area:
A
972 (SF)
Layout:
Access:
Structural Frame:
Roof Deck:
Drainage:
Slope: 4 in 12
Structure:
Roof Category: Metal Panel
Metal Roof Type:
Attachment Surface:
Panel Attachment:
Roof Overlaid:
Flashing Types:
Panel Type:
Accessories:
Layers:
Underlayment:
Misc.
METAL PANEL - STANDING SEAM - SEPARATE CAP Snap-on
Covering & Flashing:
ERSL = 10+
Comments:
Base Metal:
Panel Finish:
NO
Roof Section Inventory Report
Page 1 of 3September 29, 2016
01547 - CHEMISTRY LAB
3/8/1980
Sec Name:
Original Construction:Area:
B
56 (SF)
Layout:
Access:
Structural Frame:
Roof Deck:
Drainage:
Slope:
Structure:
Roof Category: Metal Panel
Metal Roof Type:
Attachment Surface:
Panel Attachment:
Roof Overlaid:
Flashing Types:
Panel Type:
Accessories:
Layers:
Underlayment:
Misc.
METAL PANEL - STANDING SEAM - SEPARATE CAP Snap-on
Covering & Flashing:
Comments:
Base Metal:
Panel Finish:
NO
Roof Section Inventory Report
Page 2 of 3September 29, 2016
Selection Criteria
Sort Criteria
Section Name Last Replacement Built Date Deck Type Roof Slope Section Area Membrane Attachment Facility Class Insulation Type Roof Type
All All All All All All All All All All
Page 3 of 3September 29, 2016
01552 - METALLURGY LAB
3/8/1985
Sec Name:
Original Construction:Area:
A
1,011 (SF)
Layout:
Access:
Structural Frame:
Roof Deck:
Drainage:
Slope: 3 in 12
Structure:
Roof Category: Metal Panel
Metal Roof Type:
Attachment Surface:
Panel Attachment:
Roof Overlaid:
Flashing Types:
Panel Type:
Accessories:
Layers:
Underlayment:
Misc.
METAL PANEL - STANDING SEAM - SEPARATE CAP Snap-on
Covering & Flashing:
ERSL = 10+
Comments:
Base Metal:
Panel Finish:
NO
Roof Section Inventory Report
Selection Criteria
Sort Criteria
Section Name Last Replacement Built Date Deck Type Roof Slope Section Area Membrane Attachment Facility Class Insulation Type Roof Type
All All All All All All All All All All
01622 - HISTORIC COMM EQUP FAC
1/1/2003WSMR
Sec Name:
Original Construction: 1/1/1959Area:
A
3,505 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
0 (LF) 161 (LF)
43 (LF) 0 (LF)
58 (LF)
0 (LF)
Access:
Adj. Roof Sec:
PENTHOUSE
B
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Bar Joists/Bearing Wall
GYPSUM: Gypsum Form
1/4 in 12
GUTTERS & DOWNSPOUTS
NONE
Structure:
Roof Category: Membrane
ROOF EDGE: Embedded Edge Metal, EXPANSION JOINT: Metal Cover, WALL/PARAPET, EQUIPMENT SUPPORT: Structural Frame, ROOF PENETRATION, ROOF RELIEF VENT, PITCH PAN, PLUMBING VENT, EQUIPMENT SUPPORT: Curbs
AGG: River Gravel
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
3-PLY
Spec. No.:
UNKNOWN
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=5-10
Base Flashing:
Counterflashing:
UNKNOWN
Membrane Mfg: UNKNOWN
UNKNOWN
Comments:
Thickness:
27.00
WOOD FIBERBOARD, EXPANDED POLYSTYRENE
Tapered:3Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
5.00 (IN)
Membrane:
Insulation:
Yes
Flashing:
Roof Section Inventory Report
Page 1 of 5June 15, 2016
01622 - HISTORIC COMM EQUP FAC
1/1/2003WSMR
Sec Name:
Original Construction: 1/1/1959Area:
B
2,538 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
0 (LF) 116 (LF)
86 (LF) 0 (LF)
0 (LF)
0 (LF)
Access:
Adj. Roof Sec:
ADJACENT SECTION
C, A
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Bar Joists/Bearing Wall
GYPSUM: Gypsum Form
1/4 in 12
GUTTERS & DOWNSPOUTS
NONE
Structure:
Roof Category: Membrane
ROOF RELIEF VENT, EQUIPMENT SUPPORT: Wood Sleepers, EXPANSION JOINT: Metal Cover, PLUMBING VENT, EXPANSION JOINT: Flexible Cover
AGG: River Gravel
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
3-PLY
Spec. No.:
METAL
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=5-10
Base Flashing:
Counterflashing:
UNKNOWN
Membrane Mfg: UNKNOWN
UNKNOWN
Comments:
Thickness:
27.00
WOOD FIBERBOARD, EXPANDED POLYSTYRENE
Tapered:3Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
5.00 (IN)
Membrane:
Insulation:
Yes
Flashing:
Roof Section Inventory Report
Page 2 of 5June 15, 2016
01622 - HISTORIC COMM EQUP FAC
1/1/2003WSMR
Sec Name:
Original Construction: 1/1/1959Area:
C
3,892 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
0 (LF) 224 (LF)
43 (LF) 0 (LF)
0 (LF)
0 (LF)
Access:
Adj. Roof Sec:
ADJACENT SECTION
B
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Bar Joists/Bearing Wall
GYPSUM: Gypsum Form
1/4 in 12
GUTTERS & DOWNSPOUTS
NONE
Structure:
Roof Category: Membrane
PITCH PAN, WALL/PARAPET, ROOF EDGE: Embedded Edge Metal, EXPANSION JOINT: Metal Cover, ROOF RELIEF VENT, EQUIPMENT SUPPORT: Wood Sleepers, PLUMBING VENT
AGG: River Gravel
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
3-PLY
Spec. No.:
METAL
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=5-10
Base Flashing:
Counterflashing:
UNKNOWN
Membrane Mfg: UNKNOWN
UNKNOWN
Comments:
Thickness:
27.00
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
Tapered:3Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
5.00 (IN)
Membrane:
Insulation:
Yes
Flashing:
Roof Section Inventory Report
Page 3 of 5June 15, 2016
01622 - HISTORIC COMM EQUP FAC
1/1/2003WSMR
Sec Name:
Original Construction: 1/1/1959Area:
D
409 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
0 (LF) 81 (LF)
0 (LF) 0 (LF)
0 (LF)
0 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
STEEL: Bar Joists/Bearing Wall
GYPSUM: Gypsum Form
1/4 in 12
GUTTERS & DOWNSPOUTS
NONE
Structure:
Roof Category: Membrane
ROOF EDGE: Embedded Edge Metal, EQUIPMENT SUPPORT: Curbs
AGG: River Gravel
Description:
Protected Mem.:
Attachment:
BITUMINOUS
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
3-PLY
Spec. No.:
MINERAL SURF: Glass
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=10+
ERSL W/O=5-10
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg: UNKNOWN
UNKNOWN
Comments:
Thickness:
27.00
WOOD FIBERBOARD, EXPANDED POLYSTYRENE
Tapered:3Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
5.00 (IN)
Membrane:
Insulation:
Yes
Flashing:
Roof Section Inventory Report
Page 4 of 5June 15, 2016 ild in g F ac il it y
C la ss S e c
N a m e
In su la ti o n
T y p e( s
R o o fi n g
T y p e
A re a
S F
S lo p e D e c k T yp e
H
IS
T O
R
IC
C O
M M
E Q
U P
F A
C R es ea rc h, D e ve lo pm en t, T e st an d E va lu at io n 3, A B
U R
: A sp ha lt
W O
O D
F
IB
E R
B O
A R
D , E
X P
A N
D E
D P
O
LY
S T
Y R
E N
E G
Y P
S U
M
G yp su m
F or m
1/
2, B
B U
R : A sp ha lt W
O O
D F
IB
E
R B
O A
R D
, E X
P A
N D
E D
P O
LY
S
T Y
R E
N E
G Y
P S
U M
G yp su m F or m
1/
3, C
B U
R : A sp ha lt E
X P
A N
D E
D P
O L
Y S
T Y
R E
N E
W
O O
D F
IB
E
R B
O A
R D
G Y
P S
U M
G yp su m F or m
1/
D B
U R
: A sp ha lt
W O
O D
F
IB
E R
B O
A R
D , E
X P
A N
D E
D P
O
LY
S T
Y R
E N
E G
Y P
S U
M
G yp su m
F or m
1/
W hi te S an ds
M is si le
R an ge
5)
R o o f
S e ct io n L is t
R ep o rt
U na ss ig n e d
T o ta ls
B u il d in g s
S e ct io n s
A re a
,3
(S F
P a ge o f
Ju n e
, 2
Date Inspected: Building:
Section:
01/31/2011 01622 - HISTORIC COMM EQUP FAC
A
Category Code:
Research, Development, Test, and Evaluation
COMMO EQ BLDG
31710
Roof Section Area: 3,505 (SF)
Roofing Type: BUR: Asphalt
374 (LF)Flashing Length: Perimeter Length: Curb Length:306 (LF) 68 (LF)
Fasteners: (EA)
83MCI of Section:MCI of Section: VERY GOOD
FCI of Section: 66 Rating: GOOD
ICI of Section: None Rating: None
RCI of Section: 71 Rating: MINOR REPAIRS NEEDED
Rating:
Severity Quantity
Flashing Distresses
Distress Type Density DeductDistresses of same type and severity are tallied
Embedded Edge Metal 4.81 17.2EM 18 (LF)Medium
Embedded Edge Metal 43.05 15.9EM 161 (LF)Low
Flashed Penetrations 4.55 23.1FP 17 (LF)High
Pitch Pans 22.81 35.8PP 85 (LF)Low
Severity Quantity
Membrane Distresses
Distress Type Density DeductDistresses of same type and severity are tallied
Debris and Vegetation 0.14 2.0DV 5 (SF)Medium
Improper Equip Supports 0.03 2.1EQ 1 (SF)Low
Surface Deterioration 0.06 4.1SR 2 (SF)High
Surface Deterioration 7.13 16.8SR 250 (SF)Medium
White Sands Missile Range (35995)
Roof Section Visual Inspection Summary
Unassigned
June 15, 2016 Page 1 of 4
01/31/2011 01622 - HISTORIC COMM EQUP FAC
B
Category Code:
Research, Development, Test, and Evaluation
COMMO EQ BLDG
31710
Roof Section Area: 2,538 (SF)
Roofing Type: BUR: Asphalt
290 (LF)Flashing Length: Perimeter Length: Curb Length:202 (LF) 88 (LF)
Fasteners: (EA)
60MCI of Section:MCI of Section: GOOD
FCI of Section: 76 Rating: VERY GOOD
ICI of Section: None Rating: None
RCI of Section: 65 Rating: MODERATE REPAIRS NEEDED
Rating:
Severity Quantity
Flashing Distresses
Distress Type Density DeductDistresses of same type and severity are tallied
Embedded Edge Metal 2.41 12.5EM 7 (LF)Medium
Embedded Edge Metal 40.00 15.7EM 116 (LF)Low
Flashed Penetrations 1.72 12.7FP 5 (LF)High
Flashed Penetrations 0.34 3.0FP 1 (LF)Low
Pitch Pans 11.31 21.3PP 33 (LF)Low
Severity Quantity
Membrane Distresses
Distress Type Density DeductDistresses of same type and severity are tallied
Holes 2.12 100.0HL 5 (EA)High
Improper Equip Supports 0.08 4.9EQ 2 (SF)Low
Surface Deterioration 1.97 12.7SR 50 (SF)Medium
White Sands Missile Range (35995)
Roof Section Visual Inspection Summary
June 15, 2016 Page 2 of 4
01/31/2011 01622 - HISTORIC COMM EQUP FAC
C
Category Code:
Research, Development, Test, and Evaluation
COMMO EQ BLDG
31710
Roof Section Area: 3,892 (SF)
Roofing Type: BUR: Asphalt
267 (LF)Flashing Length: Perimeter Length: Curb Length:267 (LF) 0 (LF)
Fasteners: (EA)
90MCI of Section:MCI of Section: EXCELLENT
FCI of Section: 73 Rating: VERY GOOD
ICI of Section: None Rating: None
RCI of Section: 78 Rating: MINOR REPAIRS NEEDED
Rating:
Severity Quantity
Flashing Distresses
Distress Type Density DeductDistresses of same type and severity are tallied
Embedded Edge Metal 1.12 8.6EM 3 (LF)Medium
Embedded Edge Metal 83.90 16.8EM 224 (LF)Low
Flashed Penetrations 0.37 10.7FP 1 (LF)High
Flashed Penetrations 0.37 3.0FP 1 (LF)Low
Pitch Pans 35.63 48.7PP 95 (LF)Low
Severity Quantity
Membrane Distresses
Distress Type Density DeductDistresses of same type and severity are tallied
Debris and Vegetation 0.03 1.0DV 1 (SF)Medium
Surface Deterioration 0.05 3.7SR 2 (SF)High
Surface Deterioration 0.77 10.4SR 30 (SF)Medium
White Sands Missile Range (35995)
Roof Section Visual Inspection Summary
June 15, 2016 Page 3 of 4
01/31/2011 01622 - HISTORIC COMM EQUP FAC
D
Category Code:
Research, Development, Test, and Evaluation
COMMO EQ BLDG
31710
Roof Section Area: 409 (SF)
Roofing Type: BUR: Asphalt
89 (LF)Flashing Length: Perimeter Length: Curb Length:81 (LF) 8 (LF)
Fasteners: (EA)
66MCI of Section:MCI of Section: GOOD
FCI of Section: 75 Rating: VERY GOOD
ICI of Section: None Rating: None
RCI of Section: 69 Rating: MODERATE REPAIRS NEEDED
Rating:
Severity Quantity
Flashing Distresses
Distress Type Density DeductDistresses of same type and severity are tallied
Embedded Edge Metal 10.11 23.8EM 9 (LF)Medium
Embedded Edge Metal 91.01 16.8EM 81 (LF)Low
Severity Quantity
Membrane Distresses
Distress Type Density DeductDistresses of same type and severity are tallied
Surface Deterioration 59.90 34.5SR 245 (SF)Medium
White Sands Missile Range (35995)
Roof Section Visual Inspection Summary
June 15, 2016 Page 4 of 4
Sec Name - Slope - Membrane Last Cons Year
Last Insp Year
Area
(SF)
RCIInsulation Type(s)
Deck Type
MCI-FCI-ICI
01622 - HISTORIC COMM EQUP
FAC
Research, Development, Test, and Evaluation
A - 1/4 - BUR: Asphalt 2003 20113,505 74
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Gypsum Form
83/66/---
B - 1/4 - BUR: Asphalt 2003 20112,538 68
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Gypsum Form
60/76/---
C - 1/4 - BUR: Asphalt 2003 20113,892 80
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Gypsum Form
90/73/---
D - 1/4 - BUR: Asphalt 2003 2011409 72
EXPANDED POLYSTYRENE, WOOD FIBERBOARD
GYPSUM: Gypsum Form
66/75/---
White Sands Missile Range (35995)
Roof Section RCI Report
Unassigned
Totals: Buildings = 1 Sections = 4 Area = 10,344
S T R E S S
S E V E R I T Y
D E F E C T
Q U A N T I T Y
N U M B E R
Building:
Section:
01622 - HISTORIC COMM EQUP FAC
A
Perimeter Flashing:
Curb Flashing:
306 (LF)
68 (LF)Inspection Date: 1/31/2011
Roof Type: Built-Up
Key Plan
Thru Panel Fasteners:
Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP) Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV) Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD) Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)
1 EM L 1 161
2 EM M 1 18
3 SR M 1 250
4 EQ L 1 1
5 FP H 4 17
6 PP L 1 26
7 SR H 1 2
8 DV M 1 5
Roof Section Inspection Worksheet History
Page 1 of 4June 15, 2016
S T R E S S
S E V E R I T Y
D E F E C T
Q U A N T I T Y
N U M B E R
Building:
Section:
01622 - HISTORIC COMM EQUP FAC
B
Perimeter Flashing:
Curb Flashing:
202 (LF)
88 (LF)Inspection Date: 1/31/2011
Roof Type: Built-Up
Key Plan
Thru Panel Fasteners:
Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP) Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV) Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD) Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)
1 EM L 1 116
2 EM M 1 7
3 EQ L 1 2
4 PP L 1 10
5 HL H 1 5
6 FP H 4 5
7 SR M 1 50
8 FP L 2 1
Roof Section Inspection Worksheet History
Page 2 of 4June 15, 2016
S T R E S S
S E V E R I T Y
D E F E C T
Q U A N T I T Y
N U M B E R
Building:
Section:
01622 - HISTORIC COMM EQUP FAC
C
Perimeter Flashing:
Curb Flashing:
267 (LF)
0 (LF)Inspection Date: 1/31/2011
Roof Type: Built-Up
Key Plan
Thru Panel Fasteners:
Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP) Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV) Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD) Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)
1 EM L 1 224
2 EM M 1 3
3 PP L 1 29
4 DV M 1 1
5 FP L 2 1
6 FP H 4 1
7 SR M 1 30
8 SR H 1 2
Roof Section Inspection Worksheet History
Page 3 of 4June 15, 2016
S T R E S S
S E V E R I T Y
D E F E C T
Q U A N T I T Y
N U M B E R
Building:
Section:
01622 - HISTORIC COMM EQUP FAC
D
Perimeter Flashing:
Curb Flashing:
81 (LF)
8 (LF)Inspection Date: 1/31/2011
Roof Type: Built-Up
Key Plan
Thru Panel Fasteners:
Base Flashing (BF) Drain & Roof Scupper (DR) Embedded Edge Metal (EM) Flashed Penetrations (FP) Metal Cap Flashing (MC) Pitch Pans (PP) Blisters (BL) Debris and Vegetation (DV) Improper Equip Supports (EQ) Holes (HL) Patching (PA) Ponding (PD) Ridges (RG) Slippage (SL) Splits (SP) Surface Deterioration (SR)
1 EM L 1 81
2 EM M 1 9
3 SR M 1 245
Roof Section Inspection Worksheet History
Page 4 of 4June 15, 2016
01623 - HISTORIC COMM EQP FAC
1/1/2002
Sec Name:
Original Construction:Area:
A
4,444 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
290 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
UNKNOWN
STEEL
Greater than 2 in 12
ROOF EDGE, GUTTERS & DOWNSPOUTS
NONE
Structure:
Roof Category: Membrane
METAL SKIN
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
PUF: Coating Unknown
Spec. No.:
NONE
Reinforcement:
Type:
MOD BIT/1-PLY: NO REINFORCEMENT
No
Surfacing:
ERSL=10+
Base Flashing:
Counterflashing:
Membrane Mfg:
Comments:
Thickness:
FOAMED-IN-PLACE/PUF
Tapered:Layers:
Types:
Attachment:
R-Value:
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 1 of 5June 15, 2016
01623 - HISTORIC COMM EQP FAC
1/1/2002
Sec Name:
Original Construction:Area:
B
1,590 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
185 (LF) 17 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
UNKNOWN
STEEL
1 in 12
ROOF EDGE
NONE
Structure:
Roof Category: Membrane
ROOF PENETRATION, EQUIPMENT SUPPORT: Curbs
METAL SKIN
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
PUF: Coating Unknown
Spec. No.:
NONE
Reinforcement:
Type:
MOD BIT/1-PLY: NO REINFORCEMENT
No
Surfacing:
ERSL W/=10+
ERSL W/O=2-3
Base Flashing:
Counterflashing:
Membrane Mfg:
Comments:
Thickness:
FOAMED-IN-PLACE/PUF
Tapered:Layers:
Types:
Attachment:
R-Value:
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 2 of 5June 15, 2016
01623 - HISTORIC COMM EQP FAC
1/1/2002
Sec Name:
Original Construction:Area:
C
221 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
35 (LF) 34 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
UNKNOWN
STEEL
1 in 12
ROOF EDGE
NONE
Structure:
Roof Category: Membrane
METAL SKIN
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
PUF: Coating Unknown
Spec. No.:
NONE
Reinforcement:
Type:
MOD BIT/1-PLY: NO REINFORCEMENT
No
Surfacing:
ERSL W/=10+
ERSL W/O=2-3
Base Flashing:
Counterflashing:
Membrane Mfg:
Comments:
Thickness:
FOAMED-IN-PLACE/PUF
Tapered:Layers:
Types:
Attachment:
R-Value:
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 3 of 5June 15, 2016
01623 - HISTORIC COMM EQP FAC
1/1/2002
Sec Name:
Original Construction:Area:
D
189 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
39 (LF) 18 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
UNKNOWN
STEEL
1 in 12
ROOF EDGE
NONE
Structure:
Roof Category: Membrane
WALL/PARAPET
METAL SKIN
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
PUF: Coating Unknown
Spec. No.:
NONE
Reinforcement:
Type:
MOD BIT/1-PLY: NO REINFORCEMENT
No
Surfacing:
ERSL W/=10+
ERSL W/O=2-3
Base Flashing:
Counterflashing:
Membrane Mfg:
Comments:
Thickness:
FOAMED-IN-PLACE/PUF
Tapered:Layers:
Types:
Attachment:
R-Value:
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 4 of 5June 15, 2016 ild in g F ac il it y
C la ss S e c
N a m e
In su la ti o n
T y p e( s
R o o fi n g
T y p e
A re a
S F
S lo p e D e c k T yp e
H
IS
T O
R
IC
C O
M M
E Q
P F
A C
R es ea rc h, D e ve lo pm en t, T e st an d
E va lu at io n
4, A
P U
F : C o at in g
U n kn o w n
F O
A M
E D
-I N
-P
LA
C E
/P U
F
S T
E E
L
1, B
P U
F : C o at in g
U n kn o w n
F O
A M
E D
-I N
-P
LA
C E
/P U
F
S T
E E
L
C P
U F
: C o at in g U n kn o w n F
O A
M E
D -I
N -P
LA
C
E /P
U F
S T
E E
L
D P
U F
: C o at in g U n kn o w n F
O A
M E
D -I
N -P
LA
C
E /P
U F
S T
E E
L
W hi te S an ds
M is si le
R an ge
5)
R o o f
S e ct io n L is t
R ep o rt
U na ss ig n e d
T o ta ls
B u il d in g s
S e ct io n s
A re a
6, S F
P a ge o f
Ju n e
, 2
Sec Name - Slope - Membrane Last Cons Year
Last Insp Year
Area
(SF)
RCIInsulation Type(s)
Deck Type
MCI-FCI-ICI
01623 - HISTORIC COMM EQP
FAC
Research, Development, Test, and Evaluation
A - > 2 - PUF: Coating Unknown 2002 -4,444 ---
FOAMED-IN-PLACE/PUF
STEEL
B - 1 - PUF: Coating Unknown 2002 -1,590 ---
FOAMED-IN-PLACE/PUF
STEEL
C - 1 - PUF: Coating Unknown 2002 -221 ---
FOAMED-IN-PLACE/PUF
STEEL
D - 1 - PUF: Coating Unknown 2002 -189 ---
FOAMED-IN-PLACE/PUF
STEEL
White Sands Missile Range (35995)
Roof Section RCI Report
Unassigned
Totals: Buildings = 1 Sections = 4 Area = 6,444
01647 - ADMIN GEN PURP
3/8/2000
Sec Name:
Original Construction:Area:
A
4,200 (SF)
Layout:
Access:
Structural Frame:
Roof Deck:
Drainage:
Slope:
Structure:
Roof Category: Metal Panel
Metal Roof Type:
Attachment Surface:
Panel Attachment:
Roof Overlaid:
Flashing Types:
Panel Type:
Accessories:
Layers:
Underlayment:
Misc.
METAL PANEL - STANDING SEAM - SEPARATE CAP Snap-on
Covering & Flashing:
SLOPE = 1
ERSL = 10+
Comments:
Base Metal:
Panel Finish:
NO
Roof Section Inventory Report ild in g F ac il it y
C la ss S e c
N a m e
In su la ti o n
T y p e( s
R o o fi n g
T y p e
A re a
S F
S lo p e D e c k T yp e
A D
M
IN
G E
N P
U R
P A dm in is tr at iv e 4, A M
E T
A L
P A
N E
L
S T
A N
D
IN
G S
E A
M
S E
P A
R A
T E
C A
P S na p-on
W hi te S an ds
M is si le
R an ge
5)
R o o f
S e ct io n L is t
R ep o rt
U na ss ig n e d
T o ta ls
B u il d in g s
S e ct io n s
A re a
4, S F
P a ge o f
Ju n e
, 2
Sec Name - Slope - Membrane Last Cons Year
Last Insp Year
Area
(SF)
RCIInsulation Type(s)
Deck Type
MCI-FCI-ICI
01647 - ADMIN GEN PURP
Administrative
A - - METAL PANEL - STANDING SEAM - SEPARATE
CAP Snap-on
2000 -4,200 ------/---/---
White Sands Missile Range (35995)
Roof Section RCI Report
Unassigned
Totals: Buildings = 1 Sections = 1 Area = 4,200
01750 - ADMIN BUILDING, GENERAL PURPSOE
5/11/1999
Sec Name:
Original Construction:Area:
A
2,120 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
186 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
UNKNOWN
GYPSUM: Precast
1/2 in 12
GUTTERS & DOWNSPOUTS
NONE
Structure:
Roof Category: Membrane
EQUIPMENT SUPPORT: Structural Frame, EQUIPMENT SUPPORT: Curbs, ROOF PENETRATION, PLUMBING VENT, ROOF EDGE: Embedded Edge Metal, PITCH PAN, PIPE SUPPORTS: Wood Blocks
AGG: Pea Gravel
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
4-PLY
Spec. No.:
MOD BIT: Granule Surface
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=5-10
ERSL W/O=5-10
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg:
Comments:
Thickness:
16.50
WOOD FIBERBOARD, POLYISOCYANURATE
Tapered:3Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
4.00 (IN)
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 1 of 4September 29, 2016
01750 - ADMIN BUILDING, GENERAL PURPSOE
5/11/1999
Sec Name:
Original Construction:Area:
B
104 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
29 (LF) 13 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
UNKNOWN
GYPSUM: Precast
1 in 12
ROOF EDGE
NONE
Structure:
Roof Category: Membrane
ROOF EDGE: Embedded Edge Metal, WALL/PARAPET
AGG: Pea Gravel
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
BUR: Asphalt
4-PLY
Spec. No.:
MOD BIT: Granule Surface
Reinforcement:
Type:
B.U.(HOT/COLD): Glass Felt
No
Surfacing:
ERSL W/=5-10
ERSL W/O=5-10
Base Flashing:
Counterflashing:
HOT MOPPED
Membrane Mfg:
Comments:
Thickness:
16.50
WOOD FIBERBOARD, POLYISOCYANURATE
Tapered:3Layers:
ADHESIVE - HOT
Types:
Attachment:
R-Value:
4.00 (IN)
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 2 of 4September 29, 2016
01750 - ADMIN BUILDING, GENERAL PURPSOE
5/11/1990
Sec Name:
Original Construction:Area:
C
20 (SF)
Layout:
Parapet: Roof Edge:
Exp. Joint:
Adj. Wall:
Area Div.: Other:
13 (LF) 5 (LF)
Access: EXTERNAL LADDER: Temporary
Structural Frame:
Roof Deck:
Vapor Retarder:
Drainage:
Slope:
UNKNOWN
PLYWOOD
1 in 12
ROOF EDGE
NONE
Structure:
Roof Category: Membrane
ROOF EDGE: Embedded Edge Metal, WALL/PARAPET
AGG: Mineral Granule
Description:
Protected Mem.:
Attachment:
NONE
NONE
Flashing Adhesive:
Types:
Walkways:
ROLL RFG: Org./Min. Surface
Spec. No.:
NONE
Reinforcement:
Type:
MOD BIT/1-PLY: Laminate Backer
No
Surfacing:
ERSL W/=0
ERSL W/O=0
Base Flashing:
Counterflashing:
Membrane Mfg:
Comments:
Thickness:
NONE
Tapered:Layers:
Types:
Attachment:
R-Value:
Membrane:
Insulation:
No
Flashing:
Roof Section Inventory Report
Page 3 of 4September 29, 2016
Selection Criteria
Sort Criteria
Section Name Last Replacement Built Date Deck Type Roof Slope Section Area Membrane Attachment Facility Class Insulation Type Roof Type
All All All All All All All All All All
Page 4 of 4September 29, 2016
File details come from the government source that posted it.