Reference_Question-Answer_33_lpp-square-straight-steel.pdf

PDF 411 KB Posted

Attached to
Rebuild Four (4) Parking Lots Federal contract opportunity
Solicitation number
W911SG-18-B-0008
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Bliss

About this file

Reference Question 33 RFIs

View the file

Other files for this federal contract opportunity

Other files attached to Rebuild Four (4) Parking Lots, newest first.
File Type Posted
Bid_Abstract_W911SG18B0008.pdf PDF
Amendment_Sol_Rebuild_Four_Parking_Lots_W911SG-18-B-0008-0003.pdf PDF
Amendment_Conform_Copy_Rebuild_Four_Parking_Lots_W911SG-18-B-0008-0003.pdf PDF
Amendment_Sol_Rebuild_Four_Parking_Lots_W911SG-18-B-0008-0002.pdf PDF
Amendment_Conform_Copy_Rebuild_Four_Parking_Lots_W911SG-18-B-0008-0002.pdf PDF
DPW037947P_Plans_Drawings_27_Aug_2018_Final_Construction_Set_Design.pdf PDF
Amendment_Conform_Copy_Rebuild_Four_Parking_Lots_W911SG-18-B-0008-0001.pdf PDF
Reference_Question-Anwer_33_lpp-24-led-area_(1).pdf PDF
DPW037937P_Plans_Drawings_24_Aug_2018_Final_Construction_Set_Design.pdf PDF
Amendment_Sol_Rebuild_Four_Parking_Lots_W911SG-18-B-0008-0001.pdf PDF
DPW047718P_Plans_Drawings_24_Aug_2018_Final_Construction_Set_Design.pdf PDF
Storm_Water_Drainage_System.pdf PDF
WSMR_Visitor_Control_Program_May_2017.pdf PDF
DPW037947P_Plans_Drawings_17_July_2018_Final_Construction_Set_Design.pdf PDF
Policy_Letter_24_-_Work_Force_Briefing_and_Training_on_the_Hazards_of_Un....pdf PDF
DPW037957P_Plans_Drawings_10_July_2018_Final_Const_Set_Design_drawings.pdf PDF
DPW037937P_Plans_Drawings_10_July_2018_Final_Construction_Set_Design.pdf PDF
DPW047718P_Plans_Drawings_11_July_2018_Final_Construction_Set_Design.pdf PDF
Solicitation_31_July_18_Rebuild_Parking_Lots_WSMR_W911SG18B0008.pdf PDF
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Engineered & Manufactured In The U

SA

Rev. V05092018 This specification brochure is intended to serve as a general guide. Our products are continually being engineered and improved, and specifications are subject to change without notice.

Project Name

Catalog #

Pole Type

Product Overview

• Pole Shaft - The pole shaft is fabricated from hot rolled welded steel tubing of one-piece construction with a minimum yield strength of 55 KSI.

• Pole Top - A removable top cap is provided for poles receiving drilling patterns for side-mount luminaire arm assemblies. Other pole top options include Tenon Top, Top Cap Only or Open Top which is typical when the pole top diameter matches the necessary slip-fit dimensions.

• Hand Hole - A reinforced hand hole with grounding provision is provided at 1’-6” from the base end of the pole assembly. Each hand hole includes a cover and cover attachment hardware. All pole assemblies are provided with a 2.5” x 5” rectangular hand hole (dimensions are nominal).

• Base Cover - A two-piece full base cover fabricated from ABS plastic is provided with each pole assembly. Additional base cover options, including a cast aluminum and fabricated steel cover, are available upon request.

• Anchor Bolts - Anchor bolts conform to ASTM F1554 Grade 55 and are provided with two hex nuts and two flat washers. Bolts have an “L” bend on one end and are galvanized a minimum of 12” on the threaded end.

• Hardware - All structural fasteners are galvanized high strength carbon steel. All non-structural fasteners are galvanized or zinc-plated carbon steel or stainless steel.

• Finish - Standard finishes are either Galvanized or Finish Painted. Additional finish options including Finish Paint over Galvanizing are available upon request.

• Design Criteria - Standard EPA (Effective Projected Area) and weight values are based on Standard Commercial Criteria (with 1.3 gust factor) for side mounted fixtures only. Consult the factory on loading criteria for pole top mounted luminaires and/or brackets. Satisfactory performance of light poles is dependent upon the pole being properly attached to a supporting foundation of adequate design.

Square Straight Steel Light Poles, Anchor Base

206 W. McWilliams St.

Suite 101 Fond du Lac, WI 54935

888-791-1463 quotes@lightpolesplus.com LightPolesPlus.com https://lightpolesplus.com

This specification brochure is intended to serve as a general guide. Our products are continually being engineered and improved, and specifications are subject to change without notice.

Engineered & Manufactured In The U

SA

Rev. V05092018

Designation & Dimensional Information

EPA Load Information

1. The total combined EPA and weight of all fixtures, brackets and attachments mounting to a light pole cannot exceed the EPA and weight rating for a specified pole.

2. Standard EPA (Effective Projected Area) and weight values are based on Standard Commercial Criteria (with 1.3 gust factor) for side mounted fixtures only. Consult the factory on loading criteria for pole top mounted luminaires and/or brackets.

3. Satisfactory performance of light poles is dependent upon the pole being properly attached to a supporting foundation of adequate design.

Note: Additional sizes and configurations are available upon request.

"+" Indicates a vibration dampener is standard

BASE MODEL

80 MPH w/1.3 GUST 90 MPH w/1.3 GUST 100 MPH w/1.3 GUST

MAX EPA

(SQFT)

MAX WEIGHT

(LBS)

MAX EPA

(SQFT)

MAX WEIGHT

(LBS)

MAX EPA

(SQFT)

MAX WEIGHT

(LBS)

VS-SSSA-10-4040-11-AB-FP 30.6 765 23.8 595 18.9 473

VS-SSSA-12-4040-11-AB-FP 24.4 610 18.8 470 14.8 370

VS-SSSA-14-4040-11-AB-FP 19.9 498 15.1 378 11.7 293

VS-SSSA-15-4040-11-AB-FP 15.9 398 11.8 295 8.9 223

VS-SSSA-16-4040-11-AB-FP 15.9 398 11.8 295 8.9 223

VS-SSSA-18-4040-11-AB-FP 12.6 315 9.2 230 6.7 168

VS-SSSA-20-4040-11-AB-FP 9.6 240 6.7 167 4.5 150

VS-SSSA-20-4040-07-AB-FP 15.8 240 12.7 167 9 150

VS-SSSA-20-5050-11-AB-FP 17.7 443 12.7 343 9.4 235

VS-SSSA-20-5050-07-AB-FP 28.1 703 21.4 535 16.2 405

VS-SSSA-25-4040-11-AB-FP 4.8 150 2.6 100 1 50

VS-SSSA-25-4040-07-AB-FP 10.8 270 7.7 188 5.4 135

VS-SSSA-25-5050-11-AB-FP 9.8 245 6.3 157 3.7 150

VS-SSSA-25-5050-07-AB-FP 18.5 463 13.3 333 9.5 238

VS-SSSA-30-4040-07-AB-FP 6.7 168 4.4 110 2.6 65

VS-SSSA-30-5050-11-AB-FP 4.7 150 2 50 N/A N/A

VS-SSSA-30-5050-07-AB-FP 10.7 267 6.7 167 3.9 100

VS-SSSA-30-6060-07-AB-FP 19 475 13.2 330 9 225

VS-SSSA-35-5050-07-AB-FP 5.9 150 2.5 100 N/A N/A

VS-SSSA-35-6060-07-AB-FP 12.4 310 7.6 190 4.2 105

VS-SSSA-40-6060-07-AB-FP 7.2 180 3 75 N/A N/A

BASE MODEL

POLE DIMENSIONS BASE PLATE ANCHOR BOLTS

NOMINAL

MOUNTING

HEIGHT

TOP SQ

(IN)

BASE SQ

(IN)

WALL

THK

(GA)

STRUCTURE

WEIGHT

(LBS)

BOLTCIRCLE

DIA (IN)

SQ (IN) x

THICK (IN)

DIA x LENGTH x

HOOK (IN)

PROJECTION

(IN)

VS-SSSA-10-4040-11-AB-FP 10’-0” 4 4 11 75 8.0 - 9.0 8.25 x 0.75 0.75 x 17.00 x 3.00 3.25 - 3.75 VS-SSSA-12-4040-11-AB-FP 12’-0” 4 4 11 90 8.0 - 9.0 8.25 x 0.75 0.75 x 17.00 x 3.00 3.25 - 3.75 VS-SSSA-14-4040-11-AB-FP 14’-0” 4 4 11 100 8.0 - 9.0 8.25 x 0.75 0.75 x 17.00 x 3.00 3.25 - 3.75 VS-SSSA-15-4040-11-AB-FP 15’-0” 4 4 11 110 8.0 - 9.0 8.25 x 0.75 0.75 x 17.00 x 3.00 3.25 - 3.75 VS-SSSA-16-4040-11-AB-FP 16’-0” 4 4 11 115 8.0 - 9.0 8.25 x 0.75 0.75 x 17.00 x 3.00 3.25 - 3.75 VS-SSSA-18-4040-11-AB-FP 18’-0” 4 4 11 125 8.0 - 9.0 8.25 x 0.75 0.75 x 17.00 x 3.00 3.25 - 3.75 VS-SSSA-20-4040-11-AB-FP 20’-0” 4 4 11 140 8.0 - 9.0 8.25 x 0.75 0.75 x 17.00 x 3.00 3.25 - 3.75 VS-SSSA-20-4040-07-AB-FP 20’-0” 4 4 7 200 8.0 - 9.0 8.25 x 0.875 0.75 x 17.00 x 3.00 3.38 - 3.88 VS-SSSA-20-5050-11-AB-FP 20’-0” 5 5 11 185 10.0 - 12.0 11 x 1 0.75 x 17.00 x 3.00 3.5 - 4 VS-SSSA-20-5050-07-AB-FP 20’-0” 5 5 7 265 10.0 - 12.0 11 x 1 0.75 x 17.00 x 3.00 3.5 - 4 VS-SSSA-25-4040-11-AB-FP 25’-0” 4 4 11 170 8.0 - 9.0 8.25 x 0.75 0.75 x 17.00 x 3.00 3.25 - 3.75 VS-SSSA-25-4040-07-AB-FP 25’-0” 4 4 7 245 8.0 - 9.0 8.25 x 0.875 0.75 x 17.00 x 3.00 3.38 - 3.88 VS-SSSA-25-5050-11-AB-FP 25’-0” 5 5 11 225 10.0 - 12.0 11 x 1 0.75 x 17.00 x 3.00 3.5 - 4 VS-SSSA-25-5050-07-AB-FP 25’-0” 5 5 7 360 10.0 - 12.0 11 x 1 0.75 x 17.00 x 3.00 3.5 - 4 VS-SSSA-30-4040-07-AB-FP 30’-0” 4 4 7 291 8.0 - 9.0 8.25 x 0.875 0.75 x 17.00 x 3.00 3.38 - 3.88 VS-SSSA-30-5050-11-AB-FP 30’-0” 5 5 11 265 10.0 - 12.0 11 x 1 0.75 x 17.00 x 3.00 3.5 - 4 VS-SSSA-30-5050-07-AB-FP 30’-0” 5 5 7 380 10.0 - 12.0 11 x 1 0.75 x 17.00 x 3.00 3.5 - 4 VS-SSSA-30-6060-07-AB-FP 30’-0” 6 6 7 520 11.0 - 13.0 12.5 x 1 1.00 x 36.00 x 4.00 4 - 4.5 VS-SSSA-35-5050-07-AB-FP 35’-0” 5 5 7 440 10.0 - 12.0 11 x 1 0.75 x 17.00 x 3.00 3.5 - 4 VS-SSSA-35-6060-07-AB-FP 35’-0” 6 6 7 540 11.0 - 13.0 12.5 x 1 1.00 x 36.00 x 4.00 4 - 4.5 VS-SSSA-40-6060-07-AB-FP 40’-0” 6 6 7 605 11.0 - 13.0 12.5 x 1 1.00 x 36.00 x 4.00 4 - 4.5

206 W. McWilliams St.

Suite 101 Fond du Lac, WI 54935

888-791-1463 quotes@lightpolesplus.com

Engineered & Manufactured In The U

SA

Rev. V05092018206 W. McWilliams St.

Suite 101 Fond du Lac, WI 54935

888-791-1463 quotes@lightpolesplus.com

Ordering Information

Options & Accessories

Engineered & Manufactured In The U

SA

Rev. V05092018

Note: Please consult factory or your sales representative to verify options and accessories will work with your light pole part number.

* See previous pages for base model configurations.

Consult factory or your sales rep for deviations from base models.

Additional sizes and configurations available upon request.

Ex. VS-SSSA-10-4040-11-AB-FP-DB-D1-EHH

Designation

VS-SSSA =

Square Straight Steel Anchor Base

Length*

10 to 40

Base OD*

40 = 4”

50 = 5”

60 = 6”

Top OD*

40 = 4”

50 = 5”

60 = 6”

Finish Type

GV = Galvanzied Only (No Paint)

FP = Finish Painted

FPGV =

Finish Paint over Galvanizing

Thickness*

07 = 7ga

11 = 11ga

Painted Color

DB = Dark Bronze

MB = Medium Bronze

LG = Light Gray

DG = Dark Green

HG = Hunter Green

SG = Slate Gray

BK = Black

WH = White

SL = Silver

NA =

Natural Alum.

Painted

SC = Custom

Fixture Mounting

Drill Mounting (includes cap)

D1 = Single

D2 = 2@180 deg.

D3 = 3@120 deg.

D4 = 4@90 deg.

D5 = 2@90 deg.

D6 = 3@90 deg.

Tenon Mounting

P1 = 4” OD x 5” Long Tenon

P2 = 2.38” OD x 4” Long Tenon

P3 = 3.50” OD x 6” Long Tenon

P4 = 4” OD x 6” Long Tenon

P5 = 2.88” OD x 4” Long Tenon

P6 = 2.88” OD x 5” Long Tenon

P7 = 2.38” OD x 5” Long Tenon

PQ = 2.38” OD x 12” Long Tenon

PD = 3” OD x 3” Long Tenon

P9 = Custom Size Tenon

Other Options

PC = Cap Only, No Side Drilling

PL = Open Top, No Cap or Side Drilling

Description

SPL = Special Cut Length (Please Specify)

BCSPCL =

Special Base Plate to Match Existing Bolt Circle (May Add 2 Weeks to Production Lead Time, May Require Special Base Cover)

VDA = Internal Vibration Dampener, Factory Installed

VDF = Internal Vibration Dampener, Field Installable

FBCS = Steel Full Base Cover

FBCP = ABS Plastic Full Base Cover

Description

ULHH = UL Compliant Hand Hole

NECHH = NEC 410.30 Compliant Hand Hole & Cover

EHH =

Additional Hand Hole Opening w/ Cover Assembly (Specify Pole Height & Orientation)

FST = Festoon Provision, Electrical by Others (Specify Pole Height & Orientation)

CPL = NPT Pipe Coupling (Specify Pole Height, Orientation & NPT Size)

PXDX = Side Drill + Tenon w/ Additional Hand Hole (Specify Tenon OD & Length)

Description

STAMP = Engineering Services, Signed & Sealed Calcs

STAMPCA = Engineering Services, CA Signed & Sealed Calcs

PRE750 = Pre-Ship Anchor Bolts - 0.75" x 17" x 3"

PRE100 = Pre-Ship Anchor Bolts - 1.0" x 36" x 4"

Anchor Bolts

AB =

Includes Anchor Bolts

LAB =

Less Anchor Bolts

206 W. McWilliams St.

Suite 101 Fond du Lac, WI 54935

888-791-1463 quotes@lightpolesplus.com