Solicitation Amendment - W911RX25QA051P0001 SF 30.pdf

PDF 726 KB Posted

Attached to
Wheeled Fire Extinguisher Maintenance Services
Solicitation number
W911RX25Q0051
Issued by

About this file

This document is a Standard Form 30 (SF 30) Amendment of Solicitation/Modification of Contract for Solicitation Number W911RX25QA051. The amendment (Number 0001) is dated 05 June 2025 and improves/clarifies Contract Line Item Number (CLIN) descriptions to facilitate contractor understanding of the requirements. The key changes involve modifying descriptions for multiple CLINs related to fire extinguisher maintenance services, specifically:

CLIN 0001, 1001, 2001, 3001, and 4001 were updated to describe "Extinguisher Inspections" as a thorough inspection process aimed at identifying and diagnosing faulty or broken parts in fire extinguishers, to be performed according to Manufacturer's Equipment Maintenance Instructions and NFPA-10 standards. Similarly, CLIN 0002, 1002, 2002, 3002, and 4002 were modified to clarify the "Six-Year Tear-Down" service as an industry standard maintenance procedure that includes replacement of faulty parts. CLIN 0003, 1003, 2003, 3003, and 4003 were changed to describe the "DEMIL (decommission)" service, which involves standard demilling of fire extinguishers and returning them to Marshall Army Airfield staff in accordance with Installation Property Book Office procedures.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

1. CONTRACT ID CODE

J

PAGE OF PAGES

1 3

2. AMENDMENT/MODIFICATION NUMBER

3. EFFECTIVE DATE

05 JUN 2025

4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)

6. ISSUED BY CODE W911RX 7. ADMINISTERED BY (If other than Item 6) CODE

W6QM MICC-FT RILEY

KO DIRECTORATE OF CONTRACTIN, 1792 12TH STRE

FORT RILEY, KS 66442-0248

UNITED STATES

NOAH YOUNGER, EMAIL: NOAH.W.YOUNGER.CIV@AR

714-8003

ET

MY.MIL TELEPHONE: (520)

SCD: PAS:

8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X) 9A. AMENDMENT OF SOLICITATION NUMBER

W911RX25QA051

9B. DATED (SEE ITEM 11)

05 JUN 2025

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED (SEE ITEM 13)

CODE

11. THIS IT

FACILITY CODE

EM ONLY APPLIES TO A

MENDMENTS OF

S

OLIC

ITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE

RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER.

If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

SEE CONTINUATION

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NUMBER IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

THIS AMENDMENT IMPROVES/CLARIFIES CLIN DESCRIPTIONS SO AS TO FACILITATE CONTRACTOR UNDERSTANDING OF THE REQUIREMENT.

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

16C. DATE SIGNED

Previous edition unusable STANDARD FORM 30 (REV. 11/2016) Prescribed by GSA FAR (48 CFR) 53.243

Selvena B. Carter

06/05/2025

W911RX25QA0510001

SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

Continuation of Supplies or Services and Prices/Costs

The following CLIN(s) / SLIN(s) / ELIN(s) were modified:

INFORMATION FROM TO

CHANGED

BY

Description

Product Service Description: CLIN 0001 Extinguisher Inspection

0001 Extinguisher Inspections This service is a thorough inspection of the fire extinguishers, aimed at identifying and diagnosing faulty or broken parts in need of repair or replacement, as well as the functional state of the fire extinguishers. This service shall be performed in accordance with the Manufacturer's Equipment Maintenance Instructions and the current NFPA-10.

Option Line Item 1001

INFORMATION FROM TO

1001 Extinguisher Inspection

1001 Extinguisher Inspections This service is a thorough inspection of the fire extinguishers, aimed at identifying and diagnosing faulty or broken parts in need of repair or replacement, as well as the functional state of the fire extinguishers. This service shall be performed in accordance with the Manufacturer's Equipment

Option Line Item 2001

2001 Extinguisher Inspection

2001 Extinguisher Inspections This service is a thorough inspection of the fire extinguishers, aimed at identifying and diagnosing faulty or broken parts in need of repair or replacement, as well as the functional state of the fire extinguishers. This service shall be performed in accordance with the Manufacturer's Equipment

Option Line Item 3001

3001 Extinguisher Inspection

3001 Extinguisher Inspections This service is a thorough inspection of the fire extinguishers, aimed at identifying and diagnosing faulty or broken parts in need of repair or replacement, as well as the functional state of the fire extinguishers. This service shall be performed in accordance with the Manufacturer's Equipment

Option Line Item 4001

4001 Extinguisher Inspection

4001 Extinguisher Inspections This service is a thorough inspection of the fire extinguishers, aimed at identifying and diagnosing faulty or broken parts in need of repair or replacement, as well as the functional state of the fire extinguishers. This service shall be performed in accordance with the Manufacturer's Equipment

0002 Extinguisher six-year tear-down

0002 Extinguisher Six-Year Tear-Down This service is the industry standard 6-year tear-down service. This service shall be performed in accordance with the Manufacturer's Equipment Maintenance Instructions and the current NFPA-10. This service also includes the replacement of faulty or broken parts as needed.

Option Line Item 1002

1002 Extinguisher Six-Year Tear- Down

002 Extinguisher Six-Year Tear-Down This service is the industry standard 6-year tear-down service. This service shall be performed in accordance with the Manufacturer's Equipment Maintenance Instructions and the current NFPA-10. This service also includes

Option Line Item 2002

2002 Extinguisher Six-Year Tear- Down

2002 Extinguisher Six-Year Tear-Down This service is the industry standard 6-year tear-down service. This service shall be performed in accordance with the Manufacturer's Equipment Maintenance Instructions and the current NFPA-10. This service also includes

Option Line Item 3002

3002 Extinguisher Six-Year Tear-

3002 Extinguisher Six-Year Tear-Down This service is the industry standard 6-year tear-down service. This service shall be performed in accordance with the Manufacturer's Equipment Maintenance Instructions and the current NFPA-10. This service also includes

Option Line Item 4002

4002 Extinguisher Six-Year Tear-

4002 Extinguisher Six-Year Tear-Down This service is the industry standard 6-year tear-down service. This service shall be performed in accordance with the Manufacturer's Equipment Maintenance Instructions and the current NFPA-10. This service also includes

0003 Extinguisher Inspection

0003 Extinguisher DEMIL (decom) This service is the industry standard demilling service. This service shall be performed in accordance with the Manufacturer's Equipment Maintenance Instructions and the current NFPA-10. Fire extinguishers decommissioned through demilling (for any reason), will be returned to Marshall Army Airfield staff for turn-in, in accordance with the procedures of the Installation Property Book Office

Option Line Item 1003

1003 Extinguisher DEMIL (decom)

1003 Extinguisher DEMIL (decom) This service is the industry standard demilling service. This service shall be performed in accordance with the Manufacturer's Equipment Maintenance Instructions and the current NFPA-10. Fire extinguishers decommissioned through demilling (for any reason), will be returned to Marshall Army Airfield staff for turn-in, in accordance with the

Option Line Item 2003

2003 Extinguisher DEMIL (decom)

2003 Extinguisher DEMIL (decom) This service is the industry standard demilling service. This service shall be performed in accordance with the Manufacturer's Equipment Maintenance Instructions and the current NFPA-10. Fire extinguishers decommissioned through demilling (for any reason), will be returned to Marshall Army Airfield staff for turn-in, in accordance with the

Option Line Item 3003

3003 Extinguisher DEMIL (decom)

3003 Extinguisher DEMIL (decom) This service is the industry standard demilling service. This service shall be performed in accordance with the Manufacturer's Equipment Maintenance Instructions and the current NFPA-10. Fire extinguishers decommissioned through demilling (for any reason), will be returned to Marshall Army Airfield staff for turn-in, in accordance with the

Option Line Item 4003

4003 Extinguisher DEMIL (decom)

4003 Extinguisher DEMIL (decom) This service is the industry standard demilling service. This service shall be performed in accordance with the Manufacturer's Equipment Maintenance Instructions and the current NFPA-10. Fire extinguishers decommissioned through demilling (for any reason), will be returned to Marshall Army Airfield staff for turn-in, in accordance with the

2025-06-05T15:48:00-0500
CARTER.SELVENA.BARBARA.1023543237