Attachment 2 Salient Characteristics Matrix W911N2-22-R-0014.xlsx
XLSX spreadsheet 23 KB Posted
- Attached to
- NDT 450kV DRCT System
- Solicitation number
- W911N2-22-R-0014
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 2 W911N2-22-R-0014-P00002 released.pdf | ||
| Amendment 1 W911N2-22-R-0014.pdf | ||
| RFP W911N2-22-R-0014 released.pdf | ||
| Synopsis W911N2-22-R-0014.pdf | ||
| Sources Sought W911N2-22-R-0014 revised.rtf | RTF text file | |
| NDT LEMC New Purchase Request Specs revised W911N2-22-R-0014.rtf | RTF text file | |
| Sources Sought W911N2-22-R-0014.rtf | RTF text file | |
| Attachment 1 W911N2-22-R-0014.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| New NDT Cabinet X-Ray System | |||||||
| Salient characteristics | Vendor A | Vendor B | Vendor C | Vendor D | Vendor E | ||
| System Capabilities | 1 | 7 axis | |||||
| 2 | Digital radiography computed tomography system | ||||||
| 3 | Ability to scan a minimum of 60 inches in diameter and 60 inch length | ||||||
| 4 | Fully shielded | ||||||
| 5 | Interlocked cabinet style | ||||||
| 6 | Must comply with applicable FDA 21CRF1020.40 | ||||||
| 7 | Flat panel detector | ||||||
| 8 | 225 kV Micro focus Tube | ||||||
| 9 | 450 HP Tube | ||||||
| 10 | DR Imaging processing acquisition workstation & software | ||||||
| 11 | Separate CT reconstruction workstation including software | ||||||
| System Specifics | 12 | Advanced 2D X-ray Inspection | |||||
| 13 | 2D Slice reconstruction | ||||||
| 14 | CT volume reconstruction for 3D inspection | ||||||
| 15 | 3D internal & external surface scanning | ||||||
| 16 | Measurement and analysis tool for factors 12-15 | ||||||
| X-ray Tube | 17 | Micro focus 225 kV directional tube voltage | |||||
| 18 | 25-225 kV mA Range 0-3 mA Power 320 W max | ||||||
| 19 | Focal spot size < 6 microns | ||||||
| 20 | Detail recognition < 2 microns | ||||||
| 21 | 10 meter high tension cable | ||||||
| 22 | Closed loop water cooler | ||||||
| 23 | X-ray software must be at least Windows 10 based | ||||||
| 24 | Automatic tube warm up | ||||||
| 25 | Automatic filament current adjustment | ||||||
| 26 | Automatic focusing | ||||||
| 27 | Automatic target loading control | ||||||
| 28 | Intensity control | ||||||
| 29 | Spare parts & service kit included | ||||||
| 450 kV HP Tube | 30 | 450/11 metal ceramic tube head | |||||
| 31 | EN 12543 Spec. 0.4mm & 1.0mm dual focal spots | ||||||
| 32 | Continuous rating: 700W/1.5mA; 1500W/3.3mA | ||||||
| 33 | 5mm Beryllium (Be) window | ||||||
| 34 | Target angle 11 degrees | ||||||
| 35 | Radiation coverage 30 degrees x 40 degrees | ||||||
| 36 | CF-450 High stability generators 1800W | ||||||
| 37 | Digital controller with enclosure features 6 operating modes: Warm up, Radiographic, Fluoroscopic, Auto, Watt & Remote Control via RS232 | ||||||
| 38 | Up to 600 stored techniques | ||||||
| 39 | I/O power distribution panel | ||||||
| 40 | 2EA 10 meter high tension cables | ||||||
| 41 | Oil to air cooler with flow & temperature interlocks | ||||||
| 42 | All other associated/applicable cables, cooling lines & documentation | ||||||
| X-ray Tube Shutter 450 kV | 43 | Four leaf, two axis tube shutter shielded for 450 kV | |||||
| 44 | Independent axis control | ||||||
| 45 | Laser alignment system | ||||||
| 46 | Spare pack of 225kV filaments | ||||||
| 47 | Spare 225kV targets | ||||||
| X-ray Detector | 48 | 4343N Gadox 17 inches x 17 inches (432mm x 432mm) image area | |||||
| 49 | DRZ+ (Gadox) Scintillator | ||||||
| 50 | 150 micron pixel pitch | ||||||
| 51 | 2880 x 2880 pixel matrix | ||||||
| 52 | 16 bit A/D conversion | ||||||
| 53 | 15 fps (1 x 1); 30 fps (2x2 pixel binning) | ||||||
| 54 | Premium CT grade tungsten shielded to 225kV (increased lifetime) | ||||||
| 55 | All other associated/applicable power & Ethernet cables | ||||||
| Manipulator | 56 | Movement of the inspection object is limited to x, z, tilt & rotation, along with detector & tube vertical movement | |||||
| 57 | All drives are motorized with variable speed multi directional joy stick operation | ||||||
| 58 | Each axis control is dependent allowing simultaneous movement of axis | ||||||
| 59 | Tethered desktop control console | ||||||
| 60 | Focal distance: 450kV tube to DDA -- 92 inches (239cm) | ||||||
| 61 | Focal distance :450kV tube to LDA -- 95 inches (241 cm) | ||||||
| 62 | 225kV Micro focus directional tube to DDA -- 80 inches (203cm) | ||||||
| 63 | Vertical axis detector -- 63 inches (160cm) | ||||||
| 64 | Vertical Axis Tube --69 inches (175cm) | ||||||
| 65 | Part manipulator -- X axis/front to back translation -- 36 inches (91cm) | ||||||
| 66 | Part manipulator -- Z axis/tube to detector translation -- 65 inches (165cm) | ||||||
| 67 | Part manipulator -- Z axis/tube to detector translation -- 65 inches (165cm) | ||||||
| 68 | Tilt Range +20/-20 degrees | ||||||
| 69 | CT precision rotation stage 360 degrees continuous Resolution 0.001 degrees | ||||||
| 70 | DDA lateral shift 32 inches (81cm) | ||||||
| 71 | Minimum 500lb (187kg) static capacity for part manipulator (not including tilt) | ||||||
| 72 | 18 inch nickel plated aluminum turn table platter, with integrated electronics | ||||||
| 73 | Heavy duty welded & precision machined frame construction | ||||||
| 74 | Precision linear bearing rail | ||||||
| 75 | Vibration isolation system | ||||||
| Cabinet | 76 | FDA 21CFR 1020.40 compliance required | |||||
| 77 | Radiation shielding to energies of 450 kV constant potential | ||||||
| 78 | Approximate dimensions: 111 inches deep x 137 inches tall x 161 inches wide (282cm deep x 347cm tall x 409cm wide) | ||||||
| 79 | Steel/lead/steel construction | ||||||
| 80 | Cable access port with cover | ||||||
| 81 | Large motorized sliding access door | ||||||
| 82 | Primary & secondary X-ray safety interlocks | ||||||
| 83 | Interior lighting | ||||||
| 84 | X-ray on warning light and audio alarm (minimum of 5 secs to alert) | ||||||
| 85 | Designed to meet all PA State and Federal X-ray safety regulations, including FDA 21 CRF 1020.40 compliance | ||||||
| 86 | Motion control module shall provide operator friendly teach/learn interface to be easily customized | ||||||
| 87 | Additional 31 inch (787mm) 4K monitor (image review quality) | ||||||
| 88 | 4 Camera Color surveillance system: Internal camera surveillance system with split screen monitors and 4 individual cameras (image review quality) | ||||||
| Computer Hardware & Software | 89 | Computer (stand alone, no network requirement) to operate the system | |||||
| DR Work Station | 90 | Windows 10 Operating system | |||||
| 91 | Eight-Core Intel Xeon Processor | ||||||
| 92 | 8 GB RAM | ||||||
| 93 | 512 GB Operating System Drive | ||||||
| 94 | 3 TB Data storage in RAID 0 configuration | ||||||
| 95 | DVD +/- RW drive | ||||||
| 96 | 10/100/1000 network interface | ||||||
| 97 | Nvidia High Performance Display adaptor | ||||||
| 98 | 31.5 inch (800mm) 4K color display (image review quality) | ||||||
| 99 | 1 EA wired keyboard & 1 EA wired mouse | ||||||
| DR Software | 100 | High performance image analysis system with a comprehensive set of image analysis tools -- Minimum ASTM E2737 & ASTM E2698 standards | |||||
| 101 | At least Windows 10 based | ||||||
| 102 | NON PROPRIETARY image storage format | ||||||
| 103 | Multiple windows interface | ||||||
| 104 | High performance image processing & measurement functions utilizing GPU technology | ||||||
| 105 | Automatic parallelization for systems with multiple CPUs and GPUs | ||||||
| 106 | Live imaging -- up to 30 frames per second | ||||||
| 107 | Live averaging | ||||||
| 108 | Live histogram | ||||||
| 109 | Live line profile | ||||||
| 110 | Live rotation between portrait and landscape mode | ||||||
| 111 | Live measurements with 1 pixel resolution | ||||||
| 112 | Live image gain/offset calibration & defective pixel correction | ||||||
| 113 | Automatic creation of technique sheet for operator record | ||||||
| 114 | Capture video into AVI files | ||||||
| 115 | Supports digital flat panel detectors LDAs & digital/analog cameras at 8, 10, 12 & 16 bits | ||||||
| 116 | Read & store images in TIFF 32 bit/16 bit/ 8 bit BMP, JPEG, RAW, & Diconde | ||||||
| DR CT Acquisition Module | 117 | Automated CT acquisition capabilities | |||||
| 118 | Capable of CT acquisition up to 10,000 angle steps | ||||||
| 119 | Automatic creation of technique sheet | ||||||
| 120 | Monitor X-ray performance & will pause the CT scan if X-ray interruption is detected | ||||||
| 121 | Acquisition of spiral CT spans | ||||||
| 122 | Ring reduction acquisition capabilities | ||||||
| 123 | Continuous fast CT acquisition module projections for fast CT scans from 5 seconds to minutes for thousands of projections | ||||||
| Reconstruction Work Station | 124 | Windows 10 Operating system | |||||
| 125 | Dual 10-core processors (total 20 cores) | ||||||
| 126 | 384 GB RAM | ||||||
| 127 | 1 TB SSD Operating system drive | ||||||
| 128 | 24 TB Hard drive with high speed raid 5 capabilities | ||||||
| 129 | 4 Nvidia High performance display adaptors for display and reconstruction | ||||||
| 130 | 15,360 total processing cores | ||||||
| 131 | 96 GB GPU memory | ||||||
| 132 | 3D rendering capabilities | ||||||
| 133 | 31.5 inch 4K display (image review quality) | ||||||
| 134 | 1 EA wired keyboard & 1 EA wired mouse | ||||||
| CT Computed Tomography Software | 135 | CT calibration, Cone beam reconstruction, 3D real time visualization & analysis tools in the same interface | |||||
| 136 | No limiting on the size of the reconstruction | ||||||
| 137 | Combines 2 or more datasets taken at different current settings | ||||||
| 138 | Significantly improves CT quality of widely varying densities | ||||||
| 139 | Increases the dynamic range of the CT dataset | ||||||
| 140 | Reduces noise & photon starvation in the CT reconstruction | ||||||
| 141 | Capable to perform local CT reconstructions of a small area of interest inside a larger object | ||||||
| 142 | Simplified, user friendly mode that allows the operator quickly navigate the full CT scanning process | ||||||
| Automatic Calibration | 143 | Optimize cone-beam CT reconstruction process & simplifies CT & µCT equipment | |||||
| Cone Beam Reconstruction | 144 | Capabilities to perform reconstruction on GPU hardware | |||||
| 145 | 3D volume rendering | ||||||
| 146 | Real time volume rendering | ||||||
| 147 | Export slices at any angle | ||||||
| 148 | Create movie animations | ||||||
| 149 | Perform localized reconstruction | ||||||
| 150 | Ring reduction, which includes a combination of hardware & software to virtually eliminate ring artifacts caused by non-uniform pixel responses | ||||||
| 3D Surface Rendering | 151 | 3D surface rendering which includes surface extraction to CAD compatible format | |||||
| 152 | Export to STL (stereo lithography) cloud points OBJ, DXF, WRL, & PLY | ||||||
| 153 | Visualization in wireframe mode | ||||||
| 154 | Map textures with reflection | ||||||
| 155 | Export an executable viewer module with a dataset to allow others to view, slice, rotate, window & manipulate the dataset on a traditional laptop or PC | ||||||
| 156 | Viewer capabilities or equivalent to the post-processing capabilities of the CT work station | ||||||
| High Accuracy Geometry Tools | 157 | High accuracy tools similar to those used with metrology applications which calculates the geometry more accurately of the scan. | |||||
| 158 | Serialized small, medium & large tools | ||||||
| 159 | Certificate of conformance of the tools | ||||||
| 160 | High accuracy CMM inspection capabilities | ||||||
| 161 | Precision engineered mounting fixtures | ||||||
| 162 | Heavy duty carrying case | ||||||
| Spiral Acquisition | 163 | Perform automated spiral acquisition with a digital flat-panel detector for scanning elongated objects that cannot fit in a traditional single exposure | |||||
| 164 | Volume stitching & the object length is only limited by the system scanning area size | ||||||
| 165 | Reduce or eliminate the cone angle artifacts caused by flat, planar features common in non-spiral CT techniques | ||||||
| Image Stitching | 166 | Capabilities to scan large parts in separate scans and then stitch multiple images into one seamless image of the part or assembly | |||||
| Sub-Pixel Resolution | 167 | Capabilities which include the designed motion of the manipulator & the software to analyze & display the scan data utilizing sub-pixel analysis routines that double the detector capabilities | |||||
| Time & Motion Analysis | 168 | 4D computed tomography module | |||||
| 169 | Creates and analyzes moving or changing parts as a dynamic, time based dataset | ||||||
| 170 | Acquires time-based data in either continuous or stepped mode | ||||||
| 171 | Generates time-sequenced images (videos) showing the motion or change in the part using continuous or stepped scans | ||||||
| Expanded Capabilities | 172 | Programmable CNC motion control utilizing programmable CNC motion control | |||||
| 173 | Detector lateral shift of at least 60 inches | ||||||
| 174 | CT continuous scan mode for faster CT scans in seconds or minutes | ||||||
| 175 | Local CT reconstruction capabilities (reconstruct a small area of interest inside a larger object) | ||||||
| 176 | NO limiting on the size of the reconstruction -- 10000 x 10000 x 10000 voxels reconstruction capabilities | ||||||
| Detector Qualification Package | 177 | Control software in an interface that allows operators to routinely monitor digital detectors | |||||
| 178 | Capabilities to allow for the qualification of DDA pixel mapping & verification of the detector quality, spatial resolution & contrast sensitivity in accordance with ASTM E2737 & ASTM E2698 | ||||||
| 179 | SMPTE Display Test pattern capabilities used for checking the quality of the display monitor for Pixel mapping qualification, Detector quality check, Spatial resolution, Contrast sensitivity check, & SMPTE display test pattern. | ||||||
| 180 | EN-462 D13 Duplex wire gauge | ||||||
| 181 | Photo light meter -- Spectroline AccuMax XRP-3000 Raido meter/photo meter kit with spectroline XS-555/L adaptor -- Kit with hard case | ||||||
| Secondary Hard Drive Set | 182 | 2EA Hot swappable hard drives in both the DR & CT work stations (acquistion & review) | |||||
| 183 | Capability to separate sensitive and non-sensitive scan data | ||||||
| 184 | Protective storage/carrying case | ||||||
| DR Hardware & Software Package | 185 | Review capabilities with high performance image analysis systems & a comprehensive set or image & analysis tools | |||||
| 186 | Windows 10 based operating system | ||||||
| 187 | NON PROPREITARY image storage format | ||||||
| 188 | High performance image processing & measurement functions utilizing GPU technology | ||||||
| 189 | Automatic parallelization for systems with multiple CPUs and GPUs | ||||||
| 190 | Histogram | ||||||
| 191 | Line profile | ||||||
| 192 | Rotation between portrait & landscape modes | ||||||
| 193 | Measurement and analysis tool for factors (Lines 185-192) | ||||||
| 194 | Read & store images in TIFF 32 bit/16 bit/ 8 bit BMP, JPEG & DICONDE | ||||||
| 195 | Seamless integration with DR software | ||||||
| 196 | DR review work station with Windows 10 operating system | ||||||
| 197 | Eight-Core Intel Xeon Processor | ||||||
| 198 | 8 GB RAM | ||||||
| 199 | 512 GB Operating System Drive | ||||||
| 200 | 3 TB Data storage in RAID 0 configuration | ||||||
| 201 | DVD +/- RW drive | ||||||
| 202 | 10/100/1000 network interface | ||||||
| 203 | Nvidia High Performance Display adaptor | ||||||
| 204 | 31.5 (800mm) 4Kcolor display (image review quality) | ||||||
| 205 | 1 EA wireless keyboard & 1 EA wireless mouse | ||||||
| Additional Components | 206 | Copper filter kit: set of copper filters for use with micro focus tubes -- 0.005 inch, 0.010 inch, 0.020 inch, 0.040 inch, 0.060 inch, 0.080 inch thick filters | |||||
| 207 | High energy copper filter kit -- set of copper filters for use with minifocus tubes -- selection of 0.093 inch, 0.250 inch, 0.375 inch thick filters | ||||||
| Documents | 208 | Technical manual -- in English -- covers system operation, routine maintenance & basic trouble shooting information -- standard commercial user/technical manual for the hardware& software requirements | |||||
| Installation | 209 | Install the system in designated building at LEMC by the COR | |||||
| Training | 210 | DR/CT System Training as designated by COR, covering digital radiography, computed tomography & operation/maintenance/safety of the system | |||||
| 211 | 6 seats to digital radiography & intro to CT training (40 hour course) as designated by the COR | ||||||
| 212 | 3 seats to Advanced CT Training (40 hour course) as designated by the COR | ||||||
| Warranty | 213 | Standard manufacturers warranty | |||||
| 214 | Extended warranty for 2 additional years | ||||||
| Maintenance | 215 | Year 1 -- hardware and software warranty/service -- 1 EA PM visit | |||||
| 216 | Year 2 -- hardware and software warranty/service -- 1 EA PM visit | ||||||
| 217 | Year 3 -- hardware and software warranty/service -- 1 EA PM visit |