W911KB18R0025_-_0003_REISSUE_PROPOSAL_SCHEDULE.pdf
PDF 1 MB Posted
- Solicitation number
- W911KB18R0025
About this file
W911KB18R0025 0003 THIS AMENDMENT IS TO REISSUE PROPOSAL SCHEDULE (BID SCHEDULE) AND REISSUE IN ITS ENTIREY DIVISION 08 - OPENINGS - SECTION 08 71 00 DOOR HARDWARE THE PROPOSAL DUE DATE IS NOT EXTENDED AND REMIANS 12 JULY 2018 @ 2PM ALASKA TIME FOR THE ABOVE LISTED PROJECT.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| redacted_copy_signed_delta_j_and_a.pdf | ||
| 18R0025-AM_04_BIDDERS_INQUIRY.pdf | ||
| W911KB18R0025_-_0002_EXTEND_DUE_DATE.pdf | ||
| W911KB18R0025-0001.pdf | ||
| EIE423-DWGS-RTA.pdf | ||
| W911KB18R0025-final.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
EIE423 NOSE DOCK 1 RENOVATION, Eielson AFB, AK
a) This amendment provides changes to the solicitation as indicated on the continuation pages of this document.
b) Proposal due date is not extended remains the same, 12 JULY 2018 @ 2 PM Alaska time.
c) YOU ARE REQUIRED TO ACKNOWLEDGE RECEIPT OF THIS AMENDMENT ON THE REVERSE SIDE OF THE STANDARD FORM 1442
1. CONTRACT ID CODE PAGE OF PAGES
1 2
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 03-Jul-2018
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W911KB18R0025
X 9B. DATED (SEE ITEM 11)
06-Jun-2018
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
03-Jul-2018
CODE
U.S. ARMY ENGINEER DISTRICT, AK
CEPOA-CT (W911KB)
PO BOX 6898
JBER AK 99506-0898
W911KB 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
a. The following drawings are substituted for the superseded documents/sections:
b. The following revised documents/sections are substituted for the superseded documents/sections: The identifier “AM#03” appears before and after new and/or revised materials, except as noted below.
SECTION 00 11 01 – PROPOSAL SCHEDULE
– Reissuing proposal schedule
NOTE: Revisions within the following documents do not contain the above referenced identifiers:
c. The following sections are deleted:
NONE
d. The following documents are added:
DIVISION 08 –OPENINGS
-Section 08 71 00 Door Hardware (Reissuing entire section)
e. The following revisions are incorporated:
NONE
f. Other:
NONE
(End of Summary of Changes)
ALL OTHER TERMS AND CONDITIONS SHALL REMAIN THE SAME.
AM#03 W911KB-18-R-0025
EIE423
PS-1
PROPOSAL SCHEDULE
RENOVATE NOSE DOCK 1
EIELSON AFB, ALASKA
BASE ITEMS
Item No. Description Quantity Unit Unit Price Amount 0001 Renovate, Nose Dock
1 within the bldg. 5 foot lines , Complete
1 Job $_________ $_________
0002 Construct Site work outside the bldg. 5 foot lines complete, Complete
1 Job $_________ $_________
AM#03…
Sample, Test and Remove Asbestos Containing Material (ACM), piping, Estimated Quantity, Complete *
115 LF $_________ $_________
0004 Sample, Test and Remove Asbestos Containing Material (ACM), fittings, Estimated Quantity, Complete *
36 Each $_________ $_________
0005 Sample, Test and Remove lead base paint material, Estimated Quantity, Complete *
100 SF $_________ $_________
0006 Sample, Test and Remove moldy material, Estimated Quantity, Complete *
100 SF $_________ $_________
Total of Base Items 0001 thru 0006 $_________...AM#03
OPTION ITEMS
W911KB-18-R-0025
PS-2
Item No. Description Quantity Unit Unit Price Amount
AM#03…
Stockpile and Sample 50 Cubic Yards of Potentially Contaminated Soil, From Field Screening, Including Construction of Holding Cells, Estimated Quantity, Complete**
50 CY $_________ $_________
0008 Dispose of 50 Cubic Yards of POL Contaminated Soil, Estimated Quantity, Complete ***
50 CY $_________ $_________
0009 Resurface Floor with high-performance coatings, Complete****
24,580 SF $_________ $_________
0010 Sample, Test and Remove Asbestos Containing Material (ACM), fittings, Estimated Quantity, Complete*****
1 Each $_________ $_________
0011 Sample, Test and Remove Asbestos Containing Material (ACM), flooring and wall components, Estimated Quantity, Complete *****
10 SF $_________ $_________
0012 Sample, Test and Remove Asbestos Containing Material (ACM), piping, Estimated Quantity, Complete ******
10 LF $_________ $_________
Total of Option Items 0007 thru 0012 $_________
Total of Base and Optional Items 0001 thru 0012 $_________...AM#03
Proposed Contract Duration: ____________________
AM#03…CLINs 0003, 0004, and 0008 are estimated quantities. Equitable adjustments will be made in accordance with FAR CLAUSE 52.211-18, VARIATION IN ESTIMATED QUANTITY
*Work on CLIN 0003 and 0004, shall be the cost for work identified in Specs 02 82 14.00 “Hazardous Materials Abatement” and Section 01 57 20.01 29 “Environmental Protection” including the packaging, transporting, and disposal of the material. Work on CLIN 0005 shall be the cost for work identified in Specs 02 83 13.00 20 “Lead in Construction” including the
AM#03 W911KB-18-R-0025
PS-1
packaging, transporting, and disposal of the material. Work on CLIN 0006 shall be the cost of work identified in Specs 02 85 00.00 20 “Mold Remediation” including the packaging, transporting, and disposal of the material. For CLINs 0003 through 0006, the Contractor shall keep a record of the amount of material being removed and disposed of.
** Work on CLIN 0007 shall be the cost for work identified in Specs 02 61 13 “Excavation and Handling of Contaminated Material” and Section 01 57 20.01 29 “Environmental Protection” that is additional to the requirements of the normal project excavation and the field screening identified in Section 31 09 20.00 29 “Field Screen Testing of Soils for POL Contamination”. For CLIN 0007, the Contractor shall keep a record of the amount of contaminated soil being excavated and disposed of. CLIN 0007 can be awarded at any time during the Construction Contract period and will not affect the duration of the contract.
*** For CLIN 0008 the Contractor shall keep a record of the amount of contaminated soil being disposed of. This is the soil determined to be contaminated through the testing of soil required by CLIN 0007 to be stockpiled and sampled. Upon completion, if the amount of contaminated soil disposed of is less than the estimated quantities shown, the Government will receive a credit based upon the unit price noted in CLIN 0008. CLIN 0008 can be awarded at any time during the Construction Contract period and will not affect the duration of the contract.
**** Work on CLIN 0009 shall be the cost for work identified in Specs 09 67 00 Flooring Overlay Resurfacer.
*****Work on CLIN 0010, 0011, and 0012 shall be the cost for work identified in Specs 02 82
14.00 “Hazardous Materials Abatement” and Section 01 57 20.01 29 “Environmental Protection” including the packaging, transporting, and disposal of the material. CLIN 0010 may be exercised up to twenty (20) times. CLIN 0011 and 0012 may be exercised up to ten (10) times.
For CLINs 0010 through 0012, the Contractor shall keep a record of the amount of material being removed and disposed of....AM#03
EVALUATION OF OFFERS.
1. AWARD: Award will be made in accordance with Section 00 22 11 - EVALUATION
FACTORS FOR AWARD.
2. INCOMPLETE OFFERS: Failure to submit an offer on all items in the schedule constitutes an incomplete offer. Incomplete offers may be rejected. Lump sum or unit prices must be shown for each item within the schedule.
3. EXTENSIONS: All extensions of the unit prices shown will be subject to verification by the Government. In case of variation between the unit price and the extension, the unit price will be considered to be the offer.
-- END OF PROPOSAL SCHEDULE --
AM #03… SECTION 087100
DOOR HARDWARE
PART 1 - GENERAL
1.1 SUMMARY:
A. Section Includes: Finish Hardware for door openings, except as otherwise specified herein.
1. Door hardware for steel (hollow metal) doors.
2. Door hardware for aluminum doors.
3. Door hardware for wood doors.
4. Door hardware for other doors indicated.
5. Keyed cylinders as indicated.
B. Related Sections:
1. Division 6: Rough Carpentry.
2. Division 8: Aluminum Doors and Frames
3. Division 8: Hollow Metal Doors and Frames.
4. Division 8: Wood Doors.
5. Division 26 Electrical
6. Division 28: Electronic Security
C. References: Comply with applicable requirements of the following standards. Where these standards conflict with other specific requirements, the most restrictive shall govern.
1. Builders Hardware Manufacturing Association (BHMA)
2. NFPA 101 Life Safety Code
3. NFPA 80 -Fire Doors and Windows
4. ANSI-A156.xx- Various Performance Standards for Finish Hardware
5. UL10C – Positive Pressure Fire Test of Door Assemblies
6. ANSI-A117.1 – Accessible and Usable Buildings and Facilities
7. DHI /ANSI A115.IG – Installation Guide for Doors and Hardware
8. ICC – International Building Code
D. Intent of Hardware Groups
1. Should items of hardware not definitely specified be required for completion of the Work, furnish such items of type and quality comparable to adjacent hardware and appropriate for service required.
2. Where items of hardware aren’t definitely or correctly specified, are required for completion of the Work, a written statement of such omission, error, or other discrepancy to be submitted to Architect, prior to date specified for receipt of bids for clarification by addendum; or, furnish such items in the type and quality established by this specification, and appropriate to the service intended.
E. Allowances
1. Refer to Division 1 for allowance amount and procedures.
F. Alternates
1. Refer to Division 1 for Alternates and procedures.
1.2 SUBSTITUTIONS:
A. Comply with Division 1.
1.3 SUBMITTALS:
B. Special Submittal Requirements: Combine submittals of this Section with Sections listed below to ensure the "design intent" of the system/assembly is understood and can be reviewed together.
C. Product Data: Manufacturer's specifications and technical data including the following:
1. Detailed specification of construction and fabrication.
2. Manufacturer's installation instructions.
3. Wiring diagrams for each electric product specified. Coordinate voltage with electrical before submitting.
4. Submit 6 copies of catalog cuts with hardware schedule.
5. Provide 9001-Quality Management and 14001-Environmental Management for products listed in Materials
Section 2.2
D. Shop Drawings - Hardware Schedule: Submit 6 complete reproducible copy of detailed hardware schedule in a vertical format.
1. List groups and suffixes in proper sequence.
2. Completely describe door and list architectural door number.
3. Manufacturer, product name, and catalog number.
4. Function, type, and style.
5. Size and finish of each item.
6. Mounting heights.
7. Explanation of abbreviations and symbols used within schedule.
8. Detailed wiring diagrams, specially developed for each opening, indicating all electric hardware, security equipment and access control equipment, and door and frame rough-ins required for specific opening.
E. Templates: Submit templates and "reviewed Hardware Schedule" to door and frame supplier and others as applicable to enable proper and accurate sizing and locations of cutouts and reinforcing.
1. Templates, wiring diagrams and "reviewed Hardware Schedule" of electrical terms to electrical for coordination and verification of voltages and locations.
F. Samples: (If requested by the Architect)
1. 1 sample of Lever and Rose/Escutcheon design, (pair).
2. 3 samples of metal finishes
G. Contract Closeout Submittals: Comply with Division 1 including specific requirements indicated.
1. Operating and maintenance manuals: Submit 3 sets containing the following.
a. Complete information in care, maintenance, and adjustment, and data on repair and replacement parts, and information on preservation of finishes.
b. Catalog pages for each product.
c. Name, address, and phone number of local representative for each manufacturer.
d. Parts list for each product.
2. Copy of final hardware schedule, edited to reflect, "As installed".
3. Copy of final keying schedule
4. As installed “Wiring Diagrams” for each piece of hardware connected to power, both low voltage and 110 volts.
5. One set of special tools required for maintenance and adjustment of hardware, including changing of cylinders.
1.4 QUALITY ASSURANCE
1. Statement of qualification for distributor and installers.
2. Statement of compliance with regulatory requirements and single source responsibility.
3. Distributor's Qualifications: Firm with 3 years experience in the distribution of commercial hardware.
a. Distributor to employ full time Architectural Hardware Consultants (AHC) for the purpose of scheduling and coordinating hardware and establishing keying schedule.
b. Hardware Schedule shall be prepared and signed by an AHC.
4. Installer's Qualifications: Firm with 3 years experienced in installation of similar hardware to that required for this Project, including specific requirements indicated.
5. Regulatory Label Requirements: Provide testing agency label or stamp on hardware for labeled openings.
a. Provide UL listed hardware for labeled and 20 minute openings in conformance with requirements for class of opening scheduled.
b. Underwriters Laboratories requirements have precedence over this specification where conflict exists.
6. Single Source Responsibility: Except where specified in hardware schedule, furnish products of only one manufacturer for each type of hardware.
B. Review Project for extent of finish hardware required to complete the Work. Where there is a conflict between these Specifications and the existing hardware, notify the Architect in writing and furnish hardware in compliance with the Specification unless otherwise directed in writing by the Architect.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Packing and Shipping: Comply with Division 1.
1. Deliver products in original unopened packaging with legible manufacturer's identification.
2. Package hardware to prevent damage during transit and storage.
3. Mark hardware to correspond with "reviewed hardware schedule".
4. Deliver hardware to door and frame manufacturer upon request.
B. Storage and Protection: Comply with manufacturer's recommendations.
1.6 PROJECT CONDITIONS:
A. Coordinate hardware with other work. Furnish hardware items of proper design for use on doors and frames of the thickness, profile, swing, security and similar requirements indicated, as necessary for the proper installation and function, regardless of omissions or conflicts in the information on the Contract Documents.
B. Review Shop Drawings for doors and entrances to confirm that adequate provisions will be made for the proper installation of hardware.
1.7 WARRANTY:
A. Refer to Conditions of the Contract
B. Manufacturer’s Warranty:
1. Closers: Lifetime
2. Exit Devices: Five Years
3. Locksets & Cylinders: Lifetime
4. All other Hardware: Two years.
1.8 OWNER’S INSTRUCTION:
A. Instruct Owner’s personnel in operation and maintenance of hardware units.
1.9 MAINTENANCE:
A. Extra Service Materials: Deliver to Owner extra materials from same production run as products installed. Package products with protective covering and identify with descriptive labels. Comply with Division 1 Closeout Submittals Section.
1. Special Tools: Provide special wrenches and tools applicable to each different or special hardware component.
2. Maintenance Tools: Provide maintenance tools and accessories supplied by hardware component manufacturer.
3. Delivery, Storage and Protection: Comply with Owner’s requirements for delivery, storage and protection of extra service materials.
B. Maintenance Service: Submit for Owner’s consideration maintenance service agreement for electronic products installed.
PART 2 - PRODUCTS
2.1 MANUFACTURERS:
A. The following manufacturers are approved subject to compliance with requirements of the Contract Documents.
Approval of manufacturers other than those listed shall be in accordance with Division 1.
Item: Manufacturer: Approved:
Hinges Stanley Bommer Continuous Hinges Stanley Bommer Locksets Best None Cylinders Best None Exit Devices Precision None, Closers Stanley None Automatic Operators Stanley D-4990 None Push/Pull Plates Trimco Hager Rockwood Push/Pull Bars Trimco Hager Rockwood Protection Plates Trimco Hager Rockwood Overhead Stops ABH None Door Stops Trimco Hager Rockwood Flush Bolts Trimco Hager Rockwood Coordinator & Brackets Trimco Hager Rockwood Threshold & Gasketing Pemko Reese,
2.2 MATERIALS:
A. Hinges: Shall be Five Knuckle Ball bearing hinges
1. Template screw hole locations
2. Bearings are to be fully hardened.
3. Bearing shell is to be consistent shape with barrel.
4. Minimum of 2 permanently lubricated non-detachable bearings on standard weight hinge and 4 permanently lubricated bearing on heavy weight hinges.
5. Equip with easily seated, non-rising pins.
6. Non Removable Pin screws shall be slotted stainless steel screws.
7. Hinges shall be full polished, front, back and barrel.
8. Hinge pin is to be fully plated.
9. Bearing assembly is to be installed after plating.
10. Sufficient size to allow 180-degree swing of door
11. Furnish five knuckles with flush ball bearings
12. Provide hinge type as listed in schedule.
13. Furnish 3 hinges per leaf to 7 foot 6 inch height. Add one for each additional 30 inches in height or fraction thereof.
14. Tested and approved by BHMA for all applicable ANSI Standards for type, size, function and finish
15. UL10C listed for Fire rated doors.
B. Geared Continuous Hinges:
1. Tested and approved by BHMA for ANSI A156.26-1996 Grade 1
2. Anti-spinning through fastener
3. UL10C listed for 3 hour Fire rating
4. Non-handed
5. Lifetime warranty
6. Provide Fire Pins for 3-hour fire ratings
7. Sufficient size to permit door to swing 180 degrees
C. Mortise Type Locks and Latches:
1. Tested and approved by BHMA for ANSI A156.13, Series 1000, Operational Grade 1, Extra-Heavy Duty, Security Grade 2 and be UL10C.
2. Furnish UL or recognized independent laboratory certified mechanical operational testing to 4 million cycles minimum.
3. Provide 9001-Quality Management and 14001-Environmental Management.
4. Fit ANSI A115.1 door preparation
5. Functions and design as indicated in the hardware groups
6. Solid, one-piece, 3/4-inch (19mm) throw, anti-friction latchbolt made of self-lubricating stainless steel
7. Deadbolt functions shall have 1 inch (25mm) throw bolt made of hardened stainless steel
8. Latchbolt and Deadbolt are to extend into the case a minimum of 3/8 inch (9.5mm) when fully extended
9. Auxiliary deadlatch to be made of one piece stainless steel, permanently lubricated
10. Provide sufficient curved strike lip to protect door trim
11. Lever handles must be of forged or cast brass, bronze or stainless steel construction and conform to ANSI A117.1.
Levers that contain a hollow cavity are not acceptable
12. Lock shall have self-aligning, thru-bolted trim
13. Levers to operate a roller bearing spindle hub mechanism
14. Mortise cylinders of lock shall have a concealed internal setscrew for securing the cylinder to the lockset. The internal setscrew will be accessible only by removing the core, with the control key, from the cylinder body.
15. Spindle to be designed to prevent forced entry from attacking of lever
16. Provide locksets with 7-pin removable and interchangeable core cylinders
17. Each lever to have independent spring mechanism controlling it
18. Core face must be the same finish as the lockset.
D. Exit Devices:
1. Exit devices to meet or exceed BHMA for ANSI 156.3, Grade 1.
2. Exit devices to be tested and certified by UL or by a recognized independent laboratory for mechanical operational testing to 10 million cycles minimum with inspection confirming Grade 1 Loaded Forces have been maintained.
3. Exit devices chassis to be investment cast steel, zinc dichromate.
4. Exit devices to have stainless steel deadlocking ¾” through latch bolt.
5. Exit devices to be equipped with sound dampening on touchbar.
6. Non-fire rated exit devices to have cylinder dogging.
7. Non-fire rated exit devices to have ¼” minimum turn hex key dogging.
8. Touchpad to be “T” style constructed of architectural metal with matching metal end caps.
9. Touchbar assembly on wide style exit devices to have a ¼” clearance to allow for vision frames.
10. All exposed exit device components to be of architectural metals and “true” architectural finishes.
11. Provide strikes as required by application.
12. Fire exit hardware to conform to UL10C and UBC 7-2. UL tested for Accident Hazard.
13. The strike is to be black powder coated finish.
14. Exit devices to have field reversible handing.
15. Provide heavy duty vandal resistant lever trim with heavy duty investment cast stainless steel components and extra strength shock absorbing overload springs. Lever shall not require resetting. Lever design to match locksets and latchsets.
16. Provide 9001-Quality Management and 14001-Environmental Management.
17. Vertical Latch Assemblies to have gravity operation, no springs.
18. Approved Manufacturers
a. The following manufacturers will be approved contingent on meeting or exceeding the above performance criteria:
1) Precision Manufactured by Stanley Security Solutions
E. Door Closers shall:
1. Tested and approved by BHMA for ANSI 156.4, Grade 1
2. UL10C certified
3. Provide 9001-Quality Management and 14001-Environmental Management.
4. Closer shall have extra-duty arms and knuckles
5. Conform to ANSI 117.1
6. Maximum 2 7/16 inch case projection with non-ferrous cover
7. Separate adjusting valves for closing and latching speed, and backcheck
8. Provide adapter plates, shim spacers and blade stop spacers as required by frame and door conditions
9. Full rack and pinion type closer with 1½“ minimum bore
10. Mount closers on non-public side of door, unless otherwise noted in specification
11. Closers shall be non-handed, non-sized and multi-sized.
F. Low Energy Operators shall:
1. Conform to ANSI/BHMA A156.19 as a low energy power opening device.
2. Be listed under UL228, UL325, UL10B, UL10C, UBC 7.2 and FCC listed.
3. Shall be non-handed.
4. Be rated for door panels weighing up to 350 lbs (160 kg).
5. The manual door closer within the Low Energy Operator shall be adjusted to meet Americans with Disabilities
Act (ADA) 5 lbs opening force [Push-Side applications only]
6. Operator shall be isolated from mounting plate with rubber mounts to mitigate the transmission of forces between the door and the operator.
7. Shall have a position encoder to communicate with microprocessor.
8. Incorporate a resetable powered operation counter that tracts both powered and non-powered cycling of the
Operator.
9. Incorporate the following adjustable settings:
i. Hold Open Timer, to 28 seconds
ii. Open Speed
iii. Backcheck Speed
iv. Vestibule Sequence Timer
10. Include DIP switch controls for:
i. On board diagnostics
ii. Power close
iii. Push and Go operation
iv. Time delay logic for electrified hardware components
11. Include terminals for auxiliary controls including:
i. Activation devices; provide two discrete inputs
ii. Vestibule sequencing
12. Control switches including:
i. Day/Night open (illuminated)
ii. Power On-Off
13. Includes adhesive Low Energy Operator mounting templates.
14. R-14 Aluminum Allow Materials
15. For non-powered operation, the unit shall function as a standard door closer with adjustable spring force size 1 thru 6.
G. Door Stops: Provide a dome floor or wall stop for every opening as listed in the hardware sets.
1. Wall stop and floor stop shall be wrought bronze, brass or stainless steel.
2. Provide fastener suitable for wall construction.
3. Coordinate reinforcement of walls where wall stop is specified.
4. Provide dome stops where wall stops are not practical. Provide spacers or carpet riser for floor conditions encountered
H. Over Head Stops: Provide a Surface mounted or concealed overhead when a floor or wall stop cannot be used or when listed in the hardware set.
1. Concealed overhead stops shall be heavy duty bronze or stainless steel.
2. Surface overhead stops shall be heavy duty bronze or stainless steel.
I. Push Plates: Provide with four beveled edges ANSI J301, .050 thickness, size as indicated in hardware set. Furnish oval-head countersunk screws to match finish.
J. Pulls with plates: Provide with four beveled edges ANSI J301, .050 thickness Plate s with ANSI J401 Pull as listed in hardware set. Provide proper fasteners for door construction.
K. Push Pull Bars: Provide ANSI J504, .1” Dia. Pull and push bar model and series as listed in hardware set. Provide proper fasteners for door construction.
L. Kickplates: Provide with four beveled edges ANSI J102, 10 inches high by width less 2 inches on single doors and 1 inch on pairs of doors. Furnish oval-head countersunk screws to match finish.
M. Mop plates: Provide with four beveled edges ANSI J103, 4 inches high by width less 1 inch on single doors and 1 inch on pairs of doors. Furnish oval-head countersunk screws to match finish.
N. Armor Plates: Provide ANSI J101 with four beveled edges, 40 inches high by width less 1 inch on single or pairs of doors. Furnish oval-head countersunk screws to match finish.
1. Provide cutouts for hardware as listed in the hardware sets.
2. Provide Warnock Hersey labeled plates for 3 hour metal fire doors where allowed by local authority.
O. Door Bolts: Flush bolts for wood or metal doors.
1. Provide a set of Automatic bolts, Certified ANSI/BHMA 156.3 Type 25 for hollow metal label doors.
2. Provide a set of Automatic bolts, Certified ANSI/BHMA 156.3 Type 27 at wood label doors.
3. Manual flush bolts, Certified ANSI/BHMA 156.16 at openings where allowed local authority.
4. Provide Dust Proof Strike, Certified ANSI/BHMA 156.16 at doors with flush bolts without thresholds.
P. Coordinator and Brackets: Provide a surface mounted coordinator when automatic bolts are used in the hardware set.
1. Coordinator, Certified ANSI/BHMA A1156.3 Type 21A for full width of the opening.
2. Provide mounting brackets for soffit applied hardware.
3. Provide hardware preparation (cutouts) for latches as necessary.
Q. Seals: All seals shall be finished to match adjacent frame color. Seals shall be furnished as listed in schedule. Material shall be UL listed for labeled openings.
R. Weatherstripping: Provide at head and jambs only those units where resilient or flexible seal strip is easily replaceable.
Where bar-type weatherstrip is used with parallel arm mounted closers install weatherstrip first.
1. Weatherstrip shall be resilient seal of (Neoprene, Polyurethane, Vinyl, Pile, Nylon Brush, Silicone)
2. UL10C Positive Pressure rated seal set when required.
S. Door Bottoms/Sweeps: Surface mounted or concealed door bottom where listed in the hardware sets.
1. Door seal shall be resilient seal of (Neoprene, Polyurethane, Nylon Brush, Silicone)
2. UL10C Positive Pressure rated seal set when required.
T. Thresholds: Thresholds shall be aluminum beveled type with maximum height of ½” for conformance with ADA requirements. Furnish as specified and per details. Provide fasteners and screws suitable for floor conditions.
U. Silencers: Furnish silencers on all interior frames, 3 for single doors, 2 for pairs. Omit where any type of seals occur.
2.3 FINISH:
A. Designations used in Schedule of Finish Hardware - 3.05, and elsewhere to indicate hardware finishes are those listed in ANSI/BHMA A156.18 including coordination with traditional U.S. finishes shown by certain manufacturers for their products
B. Powder coat door closers to match other hardware, unless otherwise noted.
C. Aluminum items shall be finished to match predominant adjacent material. Seals to coordinate with frame color.
2.4 KEYS AND KEYING:
A. Provide keyed brass construction cores and keys during the construction period. Construction control and operating keys and core shall not be part of the Owner's permanent keying system or furnished in the same keyway (or key section) as the Owner's permanent keying system. Permanent cores and keys (prepared according to the accepted keying schedule) will be furnished to the Owner.
B. Cylinders, removable and interchangeable core system: Best CORMAX™ Patented 7-pin.
C. Permanent keys and cores: Stamped with the applicable key mark for identification. These visual key control marks or codes will not include the actual key cuts. Permanent keys will also be stamped "Do Not Duplicate."
D. The vendor shall transmit key codes, cores and keys to the base lock smith for final installation and key control.
E. Furnish keys in the following quantities: 1 each operating key per core.
F. The Owner, or the Owner's agent, will install permanent cores and return the construction cores to the Hardware Supplier.
Construction cores and keys remain the property of the Hardware Supplier.
G. Keying Schedule: Arrange for a keying meeting, and programming meeting with Architect Owner and hardware supplier, and other involved parties to ensure locksets and locking hardware, are functionally correct and keying and programming complies with project requirements. Furnish 3 typed copies of keying and programming schedule to Architect.
Option List
Code Description P Full Size Plastic Cover RM For Rim Device
B4E BEVELED 4 EDGES - KICK PLATES
CSK COUNTER SINKING OF KICK and MOP PLATES PH2 for Precision 2000 series device MSES10 MS&ES10 (for 36")
Finish List
626 Satin Chromium Plated 628 Satin Aluminum, Clear Anodized
630 Satin Stainless Steel 689 Aluminum Painted GREY Grey US26D Chromium Plated, Dull US32D Stainless Steel, Dull
Manufacturer List
Code Name AB ABH Manufacturing Inc.
BE Best Access Systems PE Pemko PR Precision SD Stanley Door Closers SH Stanley Commercial Hardware ST Stanley TR Trimco
Hardware Sets
SET #1
Doors: 29, 4B
3 Hinges FBB179 4 1/2 X 4 1/2 NRP US26D ST 1 Lockset 45H-7AB16J PATD 630 BE 1 Door Closer QDC115 P 689 SH 1 Kick Plate K0050 10" x 2" LDW B4E CSK 630 TR 1 Wall Bumper 1270CXSV 626 TR 1 Smoke Seal S88 D (HEAD AND JAMBS) PE
SET #2
Doors: 38
3 Hinges FBB179 4 1/2 X 4 1/2 NRP US26D ST 1 Lockset 45H-7D16J PATD 630 BE 1 Kick Plate K0050 10" x 2" LDW B4E CSK 630 TR 1 Wall Bumper 1270CXSV 626 TR 3 Door Silencers 1229A GREY TR
SET #3
Doors: 28, 30, 31, 32
3 Hinges FBB179 4 1/2 X 4 1/2 NRP US26D ST 1 Lockset 45H-7AB16J PATD 630 BE 1 Kick Plate K0050 10" x 2" LDW B4E CSK 630 TR 1 Wall Bumper 1270CXSV 626 TR 3 Door Silencers 1229A GREY TR
SET #4
Doors: 36A, 36B
6 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 2 Flush Bolt 3917-12 626 TR 1 Lockset 45H-7D16J PATD 630 BE 2 Door Closer QDC113 P 689 SH 2 Kick Plate K0050 10" x 1" B4E CSK 630 TR 1 Dustproof Strike 3910 626 TR 1 Smoke Seal S88 D (HEAD AND JAMBS) PE 1 Astragal 355CS PE
SET #5
Doors: 14, 42B, 4A, 5
3 Hinges FBB179 4 1/2 X 4 1/2 NRP US26D ST 1 Lockset 45H-7R16J PATD 630 BE 1 Door Closer QDC115 P 689 SH 1 Kick Plate K0050 10" x 2" LDW B4E CSK 630 TR 1 Wall Bumper 1270CXSV 626 TR 1 Smoke Seal S88 D (HEAD AND JAMBS) PE
SET #6
Doors: 16, 7
6 Hinges FBB179 4 1/2 X 4 1/2 NRP US26D ST 2 Flush Bolt 3917-12 626 TR 1 Lockset 45H-7D16J PATD 630 BE 1 Overhead Stop 4420 SERIES US32D AB 1 Wall Bumper 1270CXSV 626 TR 1 Dustproof Strike 3910 626 TR 2 Astragal 355CS PE
SET #7
Doors: 18B, 20, 22
3 Hinges FBB199 4 1/2 X 4 1/2 NRP US32D ST 1 Lockset 45H-7D16J PATD 630 BE 1 Door Closer QDC113 P 689 SH 1 Overhead Stop 1023 US32D AB 1 Kick Plate K0050 10" x 2" LDW B4E CSK 630 TR 1 Weatherstrip 305 CR Head & Jambs PE 1 Raindrip 346C 4"ODW PE 1 Door Bottom 315 CN PE 1 Threshold 253 x 3AFG Full Width PE
SET #8
Doors: 17A, 17D
1 Continuous Hinge 651HD UL 7'0" US32D ST 1 Exit Device 2103 630 PR 1 Electronic Exit Device Trim EXG-7EV15MS PATD PH2 RM 626 BE 1 Rim Cylinder 12E-72 PATD 626 BE 1 Low Energy Operator CLD-4990 628 SD 1 Kick Plate K0050 10" x 2" LDW B4E CSK 630 TR 1 Wall Bumper 1270CXSV 626 TR 1 Actuator CL4163 630 SD 1 Weatherstrip 305 CR Head & Jambs PE
1 Door Bottom 315 CN PE 1 Threshold 253 x 3AFG Full Width PE
SET #9
Doors: 24A, 24B, 24C, 24D, 25
1 Continuous Hinge 651HD UL 7'0" US32D ST 1 Exit Device 2103 X 4903A 630 PR 1 Rim Cylinder 12E-72 PATD 626 BE 1 Door Closer QDC113 P 689 SH 1 Overhead Stop 1023 US32D AB 1 Kick Plate K0050 10" x 2" LDW B4E CSK 630 TR 1 Weatherstrip 305 CR Head & Jambs PE 1 Door Bottom 315 CN PE 1 Threshold 253 x 3AFG Full Width PE
SET #10
Doors: 6
3 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 1 Lockset 45H-7D16J PATD 630 BE 1 Kick Plate K0050 10" x 2" LDW B4E CSK 630 TR 1 Wall Bumper 1270CXSV 626 TR 3 Door Silencers 1229A GREY TR
SET #11
Doors: 17B, 17C, 17E, 17F, 17G
3 Hinges FBB199 4 1/2 X 4 1/2 NRP US32D ST 1 Exit Device 2101 630 PR 1 Door Closer QDC113 P 689 SH 1 Overhead Stop 1023 US32D AB 1 Kick Plate K0050 10" x 2" LDW B4E CSK 630 TR 1 Weatherstrip 305 CR Head & Jambs PE 1 Raindrip 346C 4"ODW PE 1 Door Bottom 315 CN PE 1 Threshold 253 x 3AFG Full Width PE
SET #12
Doors: 21
6 Hinges FBB199 4 1/2 X 4 1/2 NRP US32D ST 2 Flush Bolt 3917-12 626 TR 2 Dustproof Strike 3910N 630 TR 1 Lockset 45H-7D16J PATD 630 BE 2 Overhead Stop 1023 US32D AB 2 Astragal 355CS PE 2 Weatherstrip 305 CR Head & Jambs PE 2 Raindrip 346C 4"ODW PE 2 Door Bottom 315 CN PE 1 Threshold 253 x 3AFG Full Width PE
SET #13
Doors: 40, 41
1 Continuous Hinge 651HD UL 7'0" US32D ST 1 Push/Pull Set 1731 Size as Required 630 TR 1 Low Energy Operator CLD-4990 628 SD 1 Overhead Stop 1023 US32D AB 1 Kick Plate K0050 10" x 2" LDW B4E CSK 630 TR 2 Actuator CL4163 630 SD 1 Weatherstrip 305 CR Head & Jambs PE 1 Raindrip 346C 4"ODW PE 1 Door Bottom 315 CN PE 1 Threshold 253 x 3AFG Full Width PE
SET #14
Doors: 42A
3 Hinges FBB179 4 1/2 X 4 1/2 NRP US26D ST 1 Lockset 45H-7R16J PATD 630 BE 1 Door Closer QDC111 P 689 SH 1 Kick Plate K0050 10" x 2" LDW B4E CSK 630 TR 1 Wall Bumper 1270CXSV 626 TR 1 Smoke Seal S88 D (HEAD AND JAMBS) PE
SET #15
Doors: 42C
6 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 2 Flush Bolt 3917-12 626 TR 2 Door Closer QDC113 P 689 SH 1 Overhead Stop 1023 US32D AB 2 Kick Plate K0050 10" x 1" B4E CSK 630 TR 1 Wall Bumper 1270CXSV 626 TR 1 Dustproof Strike 3910 626 TR 1 Smoke Seal S88 D (HEAD AND JAMBS) PE 1 Astragal 355CS PE
…AM #03
AM #03… SECTION 087100
DOOR HARDWARE
PART 1 - GENERAL
1.1 SUMMARY:
A. Section Includes: Finish Hardware for door openings, except as otherwise specified herein.
1. Door hardware for steel (hollow metal) doors.
2. Door hardware for aluminum doors.
3. Door hardware for wood doors.
4. Door hardware for other doors indicated.
5. Keyed cylinders as indicated.
B. Related Sections:
1. Division 6: Rough Carpentry.
2. Division 8: Aluminum Doors and Frames
3. Division 8: Hollow Metal Doors and Frames.
4. Division 8: Wood Doors.
5. Division 26 Electrical
6. Division 28: Electronic Security
C. References: Comply with applicable requirements of the following standards. Where these standards conflict with other specific requirements, the most restrictive shall govern.
1. Builders Hardware Manufacturing Association (BHMA)
2. NFPA 101 Life Safety Code
3. NFPA 80 -Fire Doors and Windows
4. ANSI-A156.xx- Various Performance Standards for Finish Hardware
5. UL10C – Positive Pressure Fire Test of Door Assemblies
6. ANSI-A117.1 – Accessible and Usable Buildings and Facilities
7. DHI /ANSI A115.IG – Installation Guide for Doors and Hardware
8. ICC – International Building Code
D. Intent of Hardware Groups
1. Should items of hardware not definitely specified be required for completion of the Work, furnish such items of type and quality comparable to adjacent hardware and appropriate for service required.
2. Where items of hardware aren’t definitely or correctly specified, are required for completion of the Work, a written statement of such omission, error, or other discrepancy to be submitted to Architect, prior to date specified for receipt of bids for clarification by addendum; or, furnish such items in the type and quality established by this specification, and appropriate to the service intended.
E. Allowances
1. Refer to Division 1 for allowance amount and procedures.
F. Alternates
1. Refer to Division 1 for Alternates and procedures.
1.2 SUBSTITUTIONS:
A. Comply with Division 1.
AM#03 RENOVATE NOSE DOCK 1
1.3 SUBMITTALS:
B. Special Submittal Requirements: Combine submittals of this Section with Sections listed below to ensure the "design intent" of the system/assembly is understood and can be reviewed together.
C. Product Data: Manufacturer's specifications and technical data including the following:
1. Detailed specification of construction and fabrication.
2. Manufacturer's installation instructions.
3. Wiring diagrams for each electric product specified. Coordinate voltage with electrical before submitting.
4. Submit 6 copies of catalog cuts with hardware schedule.
5. Provide 9001-Quality Management and 14001-Environmental Management for products listed in Materials
Section 2.2
D. Shop Drawings - Hardware Schedule: Submit 6 complete reproducible copy of detailed hardware schedule in a vertical format.
1. List groups and suffixes in proper sequence.
2. Completely describe door and list architectural door number.
3. Manufacturer, product name, and catalog number.
4. Function, type, and style.
5. Size and finish of each item.
6. Mounting heights.
7. Explanation of abbreviations and symbols used within schedule.
8. Detailed wiring diagrams, specially developed for each opening, indicating all electric hardware, security equipment and access control equipment, and door and frame rough-ins required for specific opening.
E. Templates: Submit templates and "reviewed Hardware Schedule" to door and frame supplier and others as applicable to enable proper and accurate sizing and locations of cutouts and reinforcing.
1. Templates, wiring diagrams and "reviewed Hardware Schedule" of electrical terms to electrical for coordination and verification of voltages and locations.
F. Samples: (If requested by the Architect)
1. 1 sample of Lever and Rose/Escutcheon design, (pair).
2. 3 samples of metal finishes
G. Contract Closeout Submittals: Comply with Division 1 including specific requirements indicated.
1. Operating and maintenance manuals: Submit 3 sets containing the following.
a. Complete information in care, maintenance, and adjustment, and data on repair and replacement parts, and information on preservation of finishes.
b. Catalog pages for each product.
c. Name, address, and phone number of local representative for each manufacturer.
d. Parts list for each product.
2. Copy of final hardware schedule, edited to reflect, "As installed".
3. Copy of final keying schedule
4. As installed “Wiring Diagrams” for each piece of hardware connected to power, both low voltage and 110 volts.
5. One set of special tools required for maintenance and adjustment of hardware, including changing of cylinders.
1.4 QUALITY ASSURANCE
A. Comply with Division 1.
AM#03 RENOVATE NOSE DOCK 1
1. Statement of qualification for distributor and installers.
2. Statement of compliance with regulatory requirements and single source responsibility.
3. Distributor's Qualifications: Firm with 3 years experience in the distribution of commercial hardware.
a. Distributor to employ full time Architectural Hardware Consultants (AHC) for the purpose of scheduling and coordinating hardware and establishing keying schedule.
b. Hardware Schedule shall be prepared and signed by an AHC.
4. Installer's Qualifications: Firm with 3 years experienced in installation of similar hardware to that required for this Project, including specific requirements indicated.
5. Regulatory Label Requirements: Provide testing agency label or stamp on hardware for labeled openings.
a. Provide UL listed hardware for labeled and 20 minute openings in conformance with requirements for class of opening scheduled.
b. Underwriters Laboratories requirements have precedence over this specification where conflict exists.
6. Single Source Responsibility: Except where specified in hardware schedule, furnish products of only one manufacturer for each type of hardware.
B. Review Project for extent of finish hardware required to complete the Work. Where there is a conflict between these Specifications and the existing hardware, notify the Architect in writing and furnish hardware in compliance with the Specification unless otherwise directed in writing by the Architect.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Packing and Shipping: Comply with Division 1.
1. Deliver products in original unopened packaging with legible manufacturer's identification.
2. Package hardware to prevent damage during transit and storage.
3. Mark hardware to correspond with "reviewed hardware schedule".
4. Deliver hardware to door and frame manufacturer upon request.
B. Storage and Protection: Comply with manufacturer's recommendations.
1.6 PROJECT CONDITIONS:
A. Coordinate hardware with other work. Furnish hardware items of proper design for use on doors and frames of the thickness, profile, swing, security and similar requirements indicated, as necessary for the proper installation and function, regardless of omissions or conflicts in the information on the Contract Documents.
B. Review Shop Drawings for doors and entrances to confirm that adequate provisions will be made for the proper installation of hardware.
1.7 WARRANTY:
A. Refer to Conditions of the Contract
B. Manufacturer’s Warranty:
1. Closers: Lifetime
2. Exit Devices: Five Years
3. Locksets & Cylinders: Lifetime
4. All other Hardware: Two years.
1.8 OWNER’S INSTRUCTION:
A. Instruct Owner’s personnel in operation and maintenance of hardware units.
AM#03 RENOVATE NOSE DOCK 1
1.9 MAINTENANCE:
A. Extra Service Materials: Deliver to Owner extra materials from same production run as products installed. Package products with protective covering and identify with descriptive labels. Comply with Division 1 Closeout Submittals Section.
1. Special Tools: Provide special wrenches and tools applicable to each different or special hardware component.
2. Maintenance Tools: Provide maintenance tools and accessories supplied by hardware component manufacturer.
3. Delivery, Storage and Protection: Comply with Owner’s requirements for delivery, storage and protection of extra service materials.
B. Maintenance Service: Submit for Owner’s consideration maintenance service agreement for electronic products installed.
PART 2 - PRODUCTS
2.1 MANUFACTURERS:
A. The following manufacturers are approved subject to compliance with requirements of the Contract Documents.
Approval of manufacturers other than those listed shall be in accordance with Division 1.
Item: Manufacturer: Approved:
Hinges Stanley Bommer Continuous Hinges Stanley Bommer Locksets Best None Cylinders Best None Exit Devices Precision None, Closers Stanley None Automatic Operators Stanley D-4990 None Push/Pull Plates Trimco Hager Rockwood Push/Pull Bars Trimco Hager Rockwood Protection Plates Trimco Hager Rockwood Overhead Stops ABH None Door Stops Trimco Hager Rockwood Flush Bolts Trimco Hager Rockwood Coordinator & Brackets Trimco Hager Rockwood Threshold & Gasketing Pemko Reese,
2.2 MATERIALS:
A. Hinges: Shall be Five Knuckle Ball bearing hinges
1. Template screw hole locations
2. Bearings are to be fully hardened.
3. Bearing shell is to be consistent shape with barrel.
4. Minimum of 2 permanently lubricated non-detachable bearings on standard weight hinge and 4 permanently lubricated bearing on heavy weight hinges.
5. Equip with easily seated, non-rising pins.
6. Non Removable Pin screws shall be slotted stainless steel screws.
7. Hinges shall be full polished, front, back and barrel.
8. Hinge pin is to be fully plated.
9. Bearing assembly is to be installed after plating.
10. Sufficient size to allow 180-degree swing of door
11. Furnish five knuckles with flush ball bearings
12. Provide hinge type as listed in schedule.
13. Furnish 3 hinges per leaf to 7 foot 6 inch height. Add one for each additional 30 inches in height or fraction thereof.
14. Tested and approved by BHMA for all applicable ANSI Standards for type, size, function and finish
15. UL10C listed for Fire rated doors.
AM#03 RENOVATE NOSE DOCK 1
B. Geared Continuous Hinges:
1. Tested and approved by BHMA for ANSI A156.26-1996 Grade 1
2. Anti-spinning through fastener
3. UL10C listed for 3 hour Fire rating
4. Non-handed
5. Lifetime warranty
6. Provide Fire Pins for 3-hour fire ratings
7. Sufficient size to permit door to swing 180 degrees
C. Mortise Type Locks and Latches:
1. Tested and approved by BHMA for ANSI A156.13, Series 1000, Operational Grade 1, Extra-Heavy Duty, Security Grade 2 and be UL10C.
2. Furnish UL or recognized independent laboratory certified mechanical operational testing to 4 million cycles minimum.
3. Provide 9001-Quality Management and 14001-Environmental Management.
4. Fit ANSI A115.1 door preparation
5. Functions and design as indicated in the hardware groups
6. Solid, one-piece, 3/4-inch (19mm) throw, anti-friction latchbolt made of self-lubricating stainless steel
7. Deadbolt functions shall have 1 inch (25mm) throw bolt made of hardened stainless steel
8. Latchbolt and Deadbolt are to extend into the case a minimum of 3/8 inch (9.5mm) when fully extended
9. Auxiliary deadlatch to be made of one piece stainless steel, permanently lubricated
10. Provide sufficient curved strike lip to protect door trim
11. Lever handles must be of forged or cast brass, bronze or stainless steel construction and conform to ANSI A117.1.
Levers that contain a hollow cavity are not acceptable
12. Lock shall have self-aligning, thru-bolted trim
13. Levers to operate a roller bearing spindle hub mechanism
14. Mortise cylinders of lock shall have a concealed internal setscrew for securing the cylinder to the lockset. The internal setscrew will be accessible only by removing the core, with the control key, from the cylinder body.
15. Spindle to be designed to prevent forced entry from attacking of lever
16. Provide locksets with 7-pin removable and interchangeable core cylinders
17. Each lever to have independent spring mechanism controlling it
18. Core face must be the same finish as the lockset.
D. Exit Devices:
1. Exit devices to meet or exceed BHMA for ANSI 156.3, Grade 1.
2. Exit devices to be tested and certified by UL or by a recognized independent laboratory for mechanical operational testing to 10 million cycles minimum with inspection confirming Grade 1 Loaded Forces have been maintained.
3. Exit devices chassis to be investment cast steel, zinc dichromate.
4. Exit devices to have stainless steel deadlocking ¾” through latch bolt.
5. Exit devices to be equipped with sound dampening on touchbar.
6. Non-fire rated exit devices to have cylinder dogging.
7. Non-fire rated exit devices to have ¼” minimum turn hex key dogging.
8. Touchpad to be “T” style constructed of architectural metal with matching metal end caps.
9. Touchbar assembly on wide style exit devices to have a ¼” clearance to allow for vision frames.
10. All exposed exit device components to be of architectural metals and “true” architectural finishes.
11. Provide strikes as required by application.
12. Fire exit hardware to conform to UL10C and UBC 7-2. UL tested for Accident Hazard.
13. The strike is to be black powder coated finish.
14. Exit devices to have field reversible handing.
15. Provide heavy duty vandal resistant lever trim with heavy duty investment cast stainless steel components and extra strength shock absorbing overload springs. Lever shall not require resetting. Lever design to match locksets and latchsets.
16. Provide 9001-Quality Management and 14001-Environmental Management.
17. Vertical Latch Assemblies to have gravity operation, no springs.
18. Approved Manufacturers
AM#03 RENOVATE NOSE DOCK 1
a. The following manufacturers will be approved contingent on meeting or exceeding the above performance criteria:
1) Precision Manufactured by Stanley Security Solutions
E. Door Closers shall:
1. Tested and approved by BHMA for ANSI 156.4, Grade 1
2. UL10C certified
3. Provide 9001-Quality Management and 14001-Environmental Management.
4. Closer shall have extra-duty arms and knuckles
5. Conform to ANSI 117.1
6. Maximum 2 7/16 inch case projection with non-ferrous cover
7. Separate adjusting valves for closing and latching speed, and backcheck
8. Provide adapter plates, shim spacers and blade stop spacers as required by frame and door conditions
9. Full rack and pinion type closer with 1½“ minimum bore
10. Mount closers on non-public side of door, unless otherwise noted in specification
11. Closers shall be non-handed, non-sized and multi-sized.
F. Low Energy Operators shall:
1. Conform to ANSI/BHMA A156.19 as a low energy power opening device.
2. Be listed under UL228,…