Specs-SEW016-AM_3.pdf

PDF 15 KB Posted

Attached to
LOWELL CREEK TUNNEL REPAIRS, SEWARD, ALASKA
Solicitation number
W911KB-16-R-0008
Issued by

About this file

Specs-SEW016-AM 3

View the file

Other files

File Type Posted
Specs-SEW016-AM_3.pdf PDF
Dwgs-SEW016-AM_3-Full_Size.pdf PDF
W911KB-16-R-0008-0003.pdf PDF
Dwgs-SEW016-AM_3-Half_Size.pdf PDF
Dwgs-SEW016-AM_3-Full_Size.pdf PDF
Dwgs-SEW016-AM_3-Half_Size.pdf PDF
W911KB-16-R-0008-0002.pdf PDF
W911KB-16-R-0008_AM_1.pdf PDF
Dwgs-SEW016-RFP-Full_Size_released.pdf PDF
Dwgs-SEW016-RFP-Half_Size_released.pdf PDF
RFP_Lowell_Creek.pdf PDF
RFP_Specifications_Lowell_Creek.pdf PDF
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AM#3 LOWELL CREEK TUNNEL REPAIRS SEW016

SEWARD, ALASKA

2.1.2.1 Unfavorable Properties

Do not provide aggregates possessing properties or constituents that are known to have specific unfavorable effects in concrete when tested in accordance with ASTM C295/C295M.

2.1.3 Chemical Admixtures

Provide chemical admixtures, when required or permitted, that conform to the appropriate specification listed.

2.1.3.1 Air-Entraining Admixture

Conform to ASTM C260/C260M and consistently cause the concrete to have an air content in the specified ranges under field conditions.

2.1.3.2 Accelerating Admixture

Meet the requirements of ASTM C494/C494M, Type C or E, except that calcium chloride or admixtures containing calcium chloride is not permitted.

2.1.3.3 Water-Reducing or Retarding Admixture

2.1.3.3.1 Water-Reducing or Retarding Admixtures

ASTM C494/C494M, Type A, B, or D, except that the 6-month and 1-year compressive strength tests are waived.

2.1.3.3.2 High-Range Water Reducing Admixture

ASTM C494/C494M, Type F or G except that the 6-month and 1-year strength requirements are waived. The admixture may be used only when approved by the Contracting Officer, such approval being contingent upon particular mixture control as described in the Contractor's Quality Control Plan.

2.1.4 Water

Provide water for mixing and curing compliance with the requirements of ASTM C1602/C1602M; potable, and free of injurious amounts of oil, acid, salt, or alkali. Submit test report showing water complies with

ASTM C1602/C1602M.

2.1.5 Nonshrink Grout

Shall conform to ASTM C1107/C1107M, and be a noncatalyzed metallic grout suitable for use in a fluid consistency. Use BASF/Master Builders' MasterFlow AM#3... 885 ...AM#3 grout, or Euclid Chemical's NS Metalic grout, or approved equal.

2.2 EQUIPMENT

Submit data on placing equipment and methods. Conform the batch plant to the requirements of NRMCA CPMB 100 and as specified; however, rating plates attached to batch plant equipment are not required. Submit batch plant data for conformance with applicable specifications.

2.2.1 Batching Equipment

Use partially automatic, semiautomatic, or automatic batching controls.

Section 03 31 01.00 10 Page 12