ABBREVIATIONS (NOT ALL USED IN THESE DRAWINGS)GENERAL NOTES
1. SCOPE OF WORK: THIS PROJECT INCLUDES REPAIRS TO THE LOWELL CREEK
TUNNEL AND ASSOCIATED INTAKE AND OUTLET TRANSITIONS. REPAIR WORK SHALL
BE ACCOMPLISHED DURING THE WINTER LOW-FLOW PERIOD. EXECUTION OF THE
WORK WILL BE HIGHLY DEPENDENT ON MAINTAINING A SUCCESSFUL STREAM
DIVERSION AND CONTROLLING SEEPAGE FLOWS BOTH INTO AND WITHIN THE
TUNNEL. WORK SHALL INCLUDE REMOVAL OF DEBRIS, LOOSE MATERIAL AND
ROCKS FROM THE INTAKE TRANSITION AND TUNNEL DOWN TO STA 2+80 FOR BASE
ITEM WORK AND BELOW STA 2+80 IN THE TUNNEL AND OUTLET TRANSITION FOR
OPTION 1 WORK. DIVERSION OF FLOW AND DISPOSAL OF LOOSE MATERIAL FROM
THE CONSTRUCTION AREA IS THE RESPONSIBILITY OF THE CONTRACTOR AND
SHALL BE COORDINATED WITH THE CITY OF SEWARD. INSTALL AND FASTEN
SECURELY ALL DEVICES NECESSARY TO PREVENT EROSION OF FRESHLY PLACED
CONCRETE BY RUNNING WATER UNTIL THE CURING PERIOD IS OVER. TUNNEL
CONDITION INDICATED IS AS OF MARCH 2015. CURRENT CONDITION IS UNKNOWN.
2. STAGING AREA AND TRAFFIC FLOW REQUIREMENTS: NO STAGING AREA IS
DESIGNATED. COORDINATE WITH THE CITY OF SEWARD. PUBLIC ACCESS ALONG
LOWELL POINT ROAD SHALL BE MAINTAINED DURING CONSTRUCTION ACTIVITIES.
ACCESS FOR CITY OF SEWARD MAINTENANCE VEHICLES TO EXISTING
INFRASTRUCTURE SHALL BE MAINTAINED TO AND ABOVE THE GATE ON LOWELL
CANYON ROAD (THE EXTENSION OF JEFFERSON STREET THAT PROVIDES VEHICLE
ACCESS TO LOWELL CREEK CANYON). TEMPORARY CLOSURES, UP TO 8 HOURS,
SHALL BE PERMITTED PROVIDED THEY ARE COORDINATED AND APPROVED BY THE
CITY OF SEWARD AND THE CONTRACTING OFFICER. ACCESS TO THE HOSPITAL
FACILITIES ALONG JEFFERSON STREET SHALL NEVER BE IMPEDED.
3. STREAM DIVERSION: LOWELL CREEK IS SUBJECT TO LARGE VARIATIONS IN FLOW
DURING ALL TIMES OF THE YEAR, INCLUDING THE WINTER LOW-FLOW PERIOD. THE
EXHIBIT DRAWING SHEET X-821 AND SPECIFICATION 01 19 40.00 29 PROVIDE THE
ONLY AVAILABLE STREAM-FLOW DATA, HOWEVER THE CONTRACTOR IS CAUTIONED
THAT THIS IS APPROXIMATE DATA BASED ON A SHORT, APPROXIMATELY 3-YEAR,
PERIOD OF RECORD. DETAILS OF THE CONTRACTOR'S DIVERSION WORKS WILL BE
EXTREMELY IMPORTANT IN MAXIMIZING THE POTENTIAL CAPACITY OF THE EXISTING
DIVERSION/STORM DRAIN, OR HIS ALTERNATIVE PLAN. THE CONTRACTOR'S
DIVERSION PLAN SHALL ANTICIPATE FLOWS EXCEEDING THE CAPACITY OF THE
EXISTING 24" CMP DIVERSION/STORM DRAIN LINE, OR HIS ALTERNATIVE PLAN, AND
ACCOMMODATE THIS WITHOUT PROLONGED DELAY OF THE WORK WHEN FLOWS
HAVE DECREASED. WATER DIVERSION WILL BE THE CONTRACTOR'S
RESPONSIBILITY TO PROPERLY CONTROL DURING ALL PHASES OF THE WORK.
APPROVAL OF THE DIVERSION PLAN BY THE CONTRACTING OFFICER SHALL BE
OBTAINED A MINIMUM OF 15 WORKING DAYS PRIOR TO START OF WORK. SUCH
APPROVAL SHALL NOT BE INTERPRETED AS AN ENDORSEMENT OF THE
CONTRACTOR'S MEANS AND METHODS, BUT SHALL RATHER INDICATE THAT THE
CONTRACTOR HAS DEMONSTRATED THAT THEY UNDERSTAND THE SITE
CONDITIONS AND CONTRACT REQUIREMENTS.
A. DIVERSION/STORM DRAIN LINE: THE 24" CMP DIVERSION/STORM DRAIN WAS
BUILT IN 1983 WITH A DESIGN CAPACITY OF 25 CFS, AND WITH A -3.3% MINIMUM
SLOPE. THE 25 CFS DESIGN CAPACITY HAS NOT BEEN CONFIRMED. THE
CURRENT CONDITION OF THIS LINE IS UNKNOWN AND THE CONTRACTOR SHALL
BE RESPONSIBLE FOR ALL REHABILITATION, REPAIR AND MAINTENANCE WORK
NECESSARY FOR ITS USE AS A DIVERSION OF LOWELL CREEK DURING THE
CONSTRUCTION WORK. CONTACT THE CITY OF SEWARD FOR THE LATEST
AVAILABLE INFORMATION REGARDING THE CONDITION OF THIS LINE.
B. CATCH BASIN AND ASSOCIATED DRAIN LINE: THE CONDITION OF THE EXISTING
CATCH BASIN AND 12" STEEL DRAIN PIPE CONNECTING IT TO THE
DIVERSION/SDMH ARE UNKNOWN. THE CONTRACTOR SHALL ASSUME THAT
THIS LINE WILL HAVE TO BE CLEARED OF SAND AND GRAVEL TO PUT IT IN
SERVICE. DETAILS OF THE CLEAN OUT GRATINGS ARE SHOWN ON THE
ORIGINAL CONSTRUCTION EXHIBIT DRAWINGS (SHEETS X-841 - X-844).
C. WATER INTRUSION IN TUNNEL: WATER INTRUSION INTO AND WITHIN THE
TUNNEL IS AND SHALL BE ANTICIPATED. SUCH INTRUSION IS KNOW TO BE FROM
WITHIN, BELOW, AND THROUGH THE INTAKE TRANSITION SLAB AND WITHIN AND
THROUGH THE TUNNEL'S CONCRETE WALLS, INVERT, AND CROWN.
4. THE CONTRACTOR SHALL COMPLY WITH THE CITY OF SEWARD NOISE ORDINANCE,
MUNICIPAL CODE CHAPTER 9.25 - NOISE CONTROL.
5. PHOTO SHEETS: PHOTO SHEETS S-901 THRU S-905 ARE PROVIDED FOR
INFORMATION ONLY AND SHALL NOT CONSTITUTE ANY GOVERNMENT
ENDORSEMENT OF MEANS AND METHODS.
6. THE ELEVATIONS AND PROFILE OF THE NEW CONCRETE SURFACES SHALL BE
CONSTRUCTED AS SHOWN ON THE 1945 EXHIBIT DRAWINGS. THE CONTRACTOR
SHALL PROVIDE SMOOTH TRANSITIONS AT THE EDGES OF WORK OR WHERE
CONSTRUCTION TO THE 1945 LINES AND GRADES WOULD CAUSE AN ABRUPT OR
IRREGULAR SURFACE CONDITION. USE INVERT CENTERLINE ELEVATIONS SHOWN
ON SECTIONS G-G AND I-I ON SHEET 2 OF 4 (X-842). DISREGARD ELEVATIONS
SHOWN AT THE STATION OF THESE SECTIONS ON SHEET 3 OF 4 (X-843).
7. CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AS REQUIRED. CONTRACTOR
SHALL PROVIDE OWN ACCESS TO TUNNEL. ICING CONDITIONS CAN BE EXPECTED
AT TUNNEL ENTRANCE AND OUTLET DURING CONSTRUCTION PERIOD, SEE PHOTOS
9 AND 15.
8. ALL ITEMS SHOWN ON THESE DRAWING ARE EXISTING UNLESS NOTED OTHERWISE
AS NEW WORK.
9. TUNNEL HISTORY:
a. 1939 START OF CONSTRUCTION
b. 1945 FINISH CONSTRUCTION
c. 1946 TURNOVER TO CITY OF SEWARD
d. 1969 REPLACE LOOSE RAILS AND CONCRETE INVERT REPLACED
e. 1974 REPAIR ERODED CONCRETE AND LOOSE RAILS
f. 1977 START OF LARGE HOLE THROUGH LINING IN THE INLET TRANSITION
g. 1982 AWARDED DESIGN CONTRACT FOR REPAIRS
h. 1982 LARGE FLOOD IN SEPTEMBER REMOVED MANY RAILS
i. 1983 LOW-FLOW 24" CMP DIVERSION /STORM DRAIN CONSTRUCTED WITH 25 CFS
DESIGN CAPACITY WITH -3.3% MINIMUM SLOPE
j. 1984 REPAIRS COMPLETED IN LATE WINTER/SPRING 1984
k. 1986 FLOOD OF RECORD IN LATE OCTOBER
l. 1988 REPAIRS COMPLETED IN LATE WINTER/SPRING 1988 m.1989 LARGE FLOOD WITH MAJOR TUNNEL DAMAGE
n. 1992 REPAIRS COMPLETED IN LATE WINTER/SPRING 1992
o. 2003 REPAIRS COMPLETED IN LATE WINTER/SPRING 2003
10. CONCRETE/SHOTCRETE: ALL CONCRETE/SHOTCRETE SHALL BE f'c=10,000 psi HARD
ROCK, SILICA FUME CONCRETE/SHOTCRETE, AS PER SPECIFICATIONS.
CONCRETE/SHOTCRETE COVER ON REINFORCING (UNO): 2" FROM FORMED
SURFACES AND 3" FROM GROUND OR ROCK SURFACES. CONTRACTOR SHALL BE
REQUIRED TO PLACE APPROXIMATELY 150 YD3 OF CONCRETE/SHOTCRETE FOR THE
ENTIRE CONSTRUCTION PROJECT.
11. NON-SHRINK GROUT: SHALL CONFORM TO ASTM C1107/C1107M, AND BE A
NONCATALYZED METALLIC GROUT SUITABLE FOR USE IN A FLUID CONSISTENCY.
USE BASF/MASTER BUILDERS' MASTERFLOW 885 GROUT, OR EUCLID CHEMICAL'S NS
METALIC GROUT, OR APPROVED EQUAL.
12. REINFORCING STEEL: DETAIL, FABRICATE, AND PLACE PER ACI-315 AND ACI-318.
SUPPORT REINFORCEMENT WITH APPROVED CHAIRS, SPACERS, OR TIES. ALL
REINFORCEMENT SHALL BE DEFORMED BAR REINFORCEMENT PER ASTM A615,
GRADE 60. ALL REINFORCING SHALL BE LAP-SPLICED A MINIMUM LAP OF 40 BAR
DIAMETERS UNO. NO MORE THAN 50% OF HORIZONTAL OR VERTICAL BARS SHALL
BE SPLICED AT ONE LOCATION.
13. STRUCTURAL STEEL: SHALL CONFORM TO THE FOLLOWING REQUIREMENTS:
TYPE OF MEMBER ASTM SPEC
PLATES, A.I.S.C. SHAPES A36
STRUCTURAL TUBING A500 GRADE B
ANCHOR BOLTS F1554, GRADE 36
STEEL TO STEEL CONNECTIONS A325N
BOLTS A307, UNO
14. WELDING: ALL WELDING SHALL BE IN CONFORMANCE WITH AISC AND AWS
STANDARDS AND SHALL BE PERFORMED BY AWS-CERTIFIED WELDERS USING E70XX,
OR EQUIVALENT, ELECTRODES. ONLY PREQUALIFED WELDS SHALL BE USED.
WHERE NO FILLET WELD SIZE IS SHOWN, PROVIDE MINIMUMS PER AISC TABLE J2.4,
BUT NOT LESS THAN 3/16".
15. ESTIMATED QUANTITIES: THE FOLLOWING QUANTITIES ARE BASED ON MARCH 2015
TUNNEL CONDITIONS WITH ESTIMATED VALUES OF WASTE/CONTINGENCY FOR NEW
WORK (SHOWN IN PARENTHESES FOLLOWING THE QUANTITY). ALL VALUES HAVE
BEEN ROUNDED UP FOR VALUES LESS THAN 20, AND ROUNDED UP TO THE NEXT
HIGHER MULTIPLE OF FIVE FOR VALUES OVER 20, IN THE UNITS STATED. WITH THE
PROVISION THAT MATERIALS MUST BE USED RESPONSIBLY, WITHOUT CARELESS
WASTE, THE GOVERNMENT REPRESENTS THAT THE FOLLOWING QUANTITIES ARE
SUFFICIENT TO CONSTRUCT THE PROJECT.
A. BASE ITEM 3: DEMOLITION EXISTING CONCRETE 10 YD3
NEW CONCRETE 14 YD3 (30%)
B. BASE ITEM 4: DEMOLITION EXISTING CONCRETE 5 YD3
WALL PRESSURE GROUT 260 GAL (25%)
NEW CONCRETE 6 YD3 (20%)
ANCHOR ROD GROUT 9 GAL (40%)
C. BASE ITEM 5: DEMOLITION EXISTING CONCRETE 12 YD3
NEW CONCRETE 15 YD3 (30%)
D. OPTIONAL ITEM 6: DEMOLITION EXISTING CONCRETE 50 YD3
NEW CONCRETE 55 YD3 (15%)
E. OPTIONAL ITEM 7: DEMOLITION EXISTING CONCRETE 50 YD3
NEW CONCRETE 55 YD3 (15%)
F. OPTIONAL ITEM 8: DEMOLITION EXISTING CONCRETE 40 FT3
NEW CONCRETE 50 FT3 (30%)
G. OPTIONAL ITEM 9 DEMOLITION EXISTING CONCRETE 9 FT3
NEW CONCRETE 10 FT3 (15%)
@ AT
# NUMBER, POUND, POUNDS
& AND
2L DOUBLE ANGLE
℄ CENTERLINE
Ø DIAMETER, ROUND
AB ANCHOR BOLT
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
AKDOT ALASKA DEPARTMENT OF
TRANSPORTATION
ALUM ALUMINUM
APPROX APPROXIMATE, APPROXIMATELY
ASTM AMERICAN SOCIETY FOR TESTING
AND MATERIALS
AWS AMERICAN WELDING SOCIETY
BJ BAR JOIST
BLDG BUILDING
BLKG BLOCKING
BOTT BOTTOM
BP BASE PLATE
C AMERICAN STANDARD CHANNELS
CB CATCH BASIN
CFS CUBIC FEET PER SECOND
CHKR CHECKER
CIP CAST IN PLACE
CJP COMPLETE JOINT PENETRATION
CL CENTERLINE
CLR CLEAR
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
CONN(S) CONNECTION(S)
CONT CONTINUOUS
COORD'S COORDINATES
CSK COUNTERSINK
DET(S) DETAIL(S)
DICA DRILL-IN-CONCRETE-ANCHOR
DIM(S) DIMENSION(S)
DIST DISTANCE
DO DITTO
DTI DIRECT TENSION INDICATOR
DWG(S) DRAWING(S)
DS DROP STRUCTURE, DOWNSTREAM
(E) EXISTING
EA EACH
EF EACH FACE
EL ELEVATION, EARTHQUAKE LOAD
ES EACH SIDE
EW EACH WAY
EXP EXPANSION
EXT EXTERIOR
f`c COMPRESSIVE STRENGTH
FAB FABRICATION
FBW FLOATING BREAKWATER
FF FINISH FLOOR
FH FLAT HEAD
FIO FOR INFORMATION ONLY
FLR FLOOR
FRT FIRE RETARDANT TREATED
FS FAR SIDE
FT FOOT OR FEET
FT³ CUBIC FEET
R RADIUS
RBW RUBBLEMOUND BREAKWATER
REBAR REINFORCING STEEL BAR(S)
RELAY USED RAILROAD RAIL
REINF REINFORCING, REINFORCEMENT,
REINFORCED
REQD REQUIRED
RO ROUGH OPENING
RP RADIUS POINT
RS RIGHT SIDE
S AMERICAN STANDARD STEEL
SHAPE, SOUTH, SPACING
SCHED SCHEDULE
SDMH STORM DRAIN MANHOLE
SECT SECTION
SHT SHEET
SIM SIMILAR
SLH SHORT LEG HORIZONTAL
SLV SHORT LEG VERTICAL
SOG SLAB ON GRADE
SPEC SPECIFICATION
SPI SEDIMENT PROFILE IMAGING
SQ SQUARE
SS STAINLESS STEEL
SSL(S) SHORT-SLOTTED HOLE(S)
SSMH SANITARY SEWER MANHOLE
ST STRUCTURAL TEE FROM THE S
SERIES SECTION
STD STANDARD, STANDARD-WEIGHT
PIPE
STL STEEL
SYM SYMMETRICAL
T TOP
TBLT TIMBER BOLT
T&B TOP & BOTTOM
THK THICK(NESS)
THRU THROUGH
TOC TOP OF CONCRETE
TR TELEPHONE RISER
TRANS TRANSVERSE
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
UHMW-PE ULTRA HIGH MOLECULAR WEIGHT
POLYETHYLENE
US UPSTREAM
USACE U.S. ARMY CORPS OF ENGINEERS
VERT VERTICAL
W W SERIES SECTION, WEST, WIDE
W/ WITH
W/O WITHOUT
WL WORK LINE
WP WORK POINT
WT WEIGHT, STRUCTURAL TEE FROM
W SERIES SECTION
WV WATER VALVE
WWF WELDED WIRE FABRIC
XS EXTRA-STRONG WEIGHT PIPE
XXS DOUBLE-EXTRA-STRONG WEIGHT
PIPE
YD(S) YARD(S)
YD³ CUBIC YARD
GA GAGE OR GAUGE
GAL GALLON(S)
GALV GALVANIZE(D), GALVANIZING
H HIGH
HAS HEADED ANCHOR STUD
HDG HOT-DIPPED GALVANIZED
HGT HEIGHT
HOR HORIZONTAL
HS HIGH-STRENGTH
HSB HIGH-STRENGTH BOLT
HSS HOLLOW STRUCTURAL SECTION
HYD FIRE HYDRANT
IE INVERT ELEVATION
INT INTERIOR
IP IRON PIPE
JB JUNCTION BOX
JT JOINT
JST JOIST
K-FT KIP-FEET
KIP 1,000 POUNDS
kN KILONEWTON(S)
L ANGLE, LONG
LB(S) POUND(S)
LIW LOAD INDICATING WASHER(S)
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG LONGITUDINAL
LS LEFT SIDE
LSL(S) LONG-SLOTTED HOLE(S)
M STEEL SHAPE FROM THE
MISCELLANEOUS SECTION
MAX MAXIMUM
MBR(S) MEMBERS(S)
MI MALLEABLE IRON
MILS THOUSANDTHS OF AN INCH
MIN MINIMUM
MISC MISCELLANEOUS
MIW MALLEABLE IRON WASHER
MPa MEGAPASCAL(S)
MPH MILES PER HOUR
MT STRUCTURAL TEE FROM THE M
SERIES SECTION
N NORTH
NIC NOT IN CONTRACT
No. NUMBER
NOM NOMINAL
NPS NOMINAL PIPE SIZE
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OPP OPPOSITE
OVS OVERSIZED HOLES
PC POINT OF CURVATURE
PJP PARTIAL JOINT PENETRATION
PL PLATE(S)
PLF POUNDS PER LINEAR FOOT
PSI POUNDS PER SQUARE INCH
PT POINT OF TANGENCY
PVI PLAN VIEW IMAGING
ALASKA DISTRICT
D R
A W
IN
G
FI
LE
D W
G S
C A
LE
P
LO
T S
C A
LE
D A
TE
A C
TI
O
N S
Y M
D R
A W
N
R E
S
ID
E N
T E
N G
IN
E
E R
D A
TE
S
TA
TE
P R
IM
E
C O
N
TR
A C
TO
R
D A
TE
D
E S
C R
IP
TI
O N
A P
P D
C
IT
Y
C O
N
TR
A C
TO
R
C O
N
TR
A C
T N
O
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
S U
B M
IT
TE
D
D E
S
IG
N E
D
R E
V
IE
W E
D
C H
IE
F, B
R A
N C
H
C H
S
E C
TI
O
N
U.
S.
A
RM
Y
EN
GI
NE
ER
D
IS
TR
IC
T
AN
CH
O
RA
G E, A
LA
SK
A
CO
RP
S O
F
EN
G
IN
EE
RS
REFERENCE
NUMBER:
SHEET OF
US ARMY CORPS
OF ENGINEERS
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10 11 12 D ra w in g
X :\U
N
IF
IE
D
\E N
-C W
\J ob s\ S
E W
6\
D w gs
\C A
D \S
E W
6-
-G
-0
.d w g la st s av ed o n
4/ 6/
:1
P
M w as p lo tte d by
T ed ric k, R ob er t C
P O
A o n 5/
/2
:1
A
M
3-
SE
W -9
3-
-0
S E
W
P
N
O . 1
W
1K B
-1 6-
R -0
M A
Y
AM#3
LO
W
E
LL
C R
E E
K T
U N
N E
L R
E P
A
IR
S S
E W
A R
D , A
LA
S
K A
VERIFY SCALES: IF THIS LINE 0 2"
DOES NOT MEASURE 2", ADJUST SCALE ACCORDINGLY.
A S
N O
TE
D
C E
P O
A -E
C -G
D.
B
LI
SS
E C
-G -H
HK.
E
IS
SE
S
RC
T
RC
T
G E
N E
R A
L 1:
S
E W
6-
-G
-0
G E
N E
R A
L
G-003
G E
N E
R A
L N
O
TE
S A
N D
A B
B R
E V
IA
TI
O N
S
AutoCAD SHX Text
AutoCAD SHX Text
18 MAY 2016
AutoCAD SHX Text
AM#3
AutoCAD SHX Text
CHANGE MASTERFLOW GROUT CALLOUT
AutoCAD SHX Text
RCT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TA
+7
S
TA
+9
1.
EL = 160.23'
S
TA
+2
S
TA
+7
5.
S
TA
+8
3.
S
TA
+1
S
TA
+0
TUNNEL
ENTRANCE
HORSESHOE SECTION
TRANSITION TO HORSESHOE SECTION
S
TA
+1
S
TA
+5
(E) 70 LB/YD RAILS AT 6" OC
AND (E) WALL CONC TO
REMAIN ABOVE STA 1+12
-4.2%
JUNCTION
OF WALL
AND INVERT
4" TYP FROM
LEFT END
10'-0" MAX 11" TYP FROM
RIGHT END
PROVIDE IF RAILS
ARE SPLICED
39'-0" (40'-0" OK) COVERAGE OF NEW 60 - 85 LB/YD ASCE RAILS
(ONE SIZE ONLY) AT 6" OC, ONE SPLICE IS OK
RIGHT SIDE, CLOSED TRANSITION PROFILE
SCALE: 1/4" = 1'-0"
A S
-2
S -5
N
E A
R S
TA
+1
A N
D S
TA
+5
B S
-2
S -5
A
LL
O
TH
E
R
LO
C A
TI
O
N S
℄ 8" WIDE ANCHOR
PLATE, TYPICAL
NOTES:
1. (E) WALL RAILS ARE SHOWN ON PREVIOUS CONTRACT DOCUMENTS AS ALL ENDING AT A GIVEN STATION (STA 1+12). THIS IMPLIES THAT THE ENDS OF THE RAILS WOULD NOT BE CUT SQUARE WITH THE LONG AXIS OF THE RAILS. PHOTOS INDICATE THAT THE RAILS ARE SQUARE CUT AND THAT THE END OF THE RAILS IS NOT VERTICAL, BUT RATHER IS PERPENDICULAR TO THE SLOPING TUNNEL LONGITUDINAL AXIS. NEW WALL RAILS SHALL BE SQUARE CUT AND SHALL BE BUTTED TIGHT TO THE ADJACENT END OF THE EXISTING WALL RAILS.
NEW ANCHOR PLATES SHALL BE PLACED WITH THEIR LONG AXIS PERPENDICULAR TO THE LENGTH OF THE
WALL RAILS, WHICH DOES NOT PLACE THEM VERTICALLY.
2. PROPOSAL ITEM No. 8, OPTION 3: REPAIR FREEZE THAW DAMAGE ON CROWN OF INTAKE PORTAL FROM STA 0+70 TO STA 0+85 ABOVE THE TRANSITION FROM WALL TO CROWN. REMOVE EXISTING SURFACE TO SOUND CONCRETE BUT TO A DEPTH THAT WILL ALLOW THE NEW CONCRETE THICKNESS TO BE NOT LESS THAN 2".
EDGES OF REPAIR AREA SHALL BE FULL DEPTH (NOT FEATHERED). FORMS SHALL PROVIDE A TIGHT SEAL AROUND ANY AND ALL STEEL PIPE PROJECTIONS FROM ORIGINAL CONCRETE SURFACE. ANY EXISTING EXPOSED, LOOSE REBAR, AND ANY REBAR EXPOSED AS A RESULT OF CONCRETE REMOVAL SHALL BE FASTENED TO THE UNDERLYING CONCRETE TO PROVIDE A MINIMUM OF 1" CLEARANCE FROM THE NEW CONCRETE SURFACE AFTER REPAIR. MEANS OF FASTENING SHALL BE COMPATIBLE WITH CONCRETE CONSTRUCTION. MECHANICALLY ROUGHEN SURFACE TO A MINIMUM 14" AMPLITUDE AND THOROUGHLY CLEAN RESULTING SURFACE PRIOR TO CONCRETE PLACEMENT. PLACE BACK WITH 10,OOO PSI SILICA FUME
CONCRETE TO MATCH THE ORIGINAL CONCRETE PROFILE.
SEE NOTE 1
APPROX SURFACE OF (E)
CONC AT INTAKE PORTAL
CROWN. SEE NOTE 2.
(E) WALL/FLOOR
CAVITY. FILL W/
CONC. SEE D/S-101.
D S-201 S-501
C S-201 S-501
APPROX (E) SOIL
SURFACE ABOVE
INTAKE PORTAL
REPAIR OF THIS
"NEAR-HORIZONTAL"
SURFACE NOT REQD
AS PART OF OPTION 3
E S-201 S-501
1:
S E
W
6-
-S -2
E
LE
V A
TI
O
N S
S-201
R
IG
H T
S
ID
E W
A
LL
C A
V
IT
Y R
E P
A
IR
A S
N O
TE
D
C E
P O
A -E
C -G
D.
B
LI
SS
E C
-G -H
HK.
E
IS
SE
S
RC
T
RC
T
S
TR
U C
TU
R
A L
ALASKA DISTRICT
D R
A W
IN
G
FI
LE
D W
G S
C A
LE
P
LO
T S
C A
LE
D A
TE
A C
TI
O
N S
Y M
D R
A W
N
R E
S
ID
E N
T E
N G
IN
E
E R
D A
TE
S
TA
TE
P R
IM
E
C O
N
TR
A C
TO
R
D A
TE
D
E S
C R
IP
TI
O N
A P
P D
C
IT
Y
C O
N
TR
A C
TO
R
C O
N
TR
A C
T N
O
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
S U
B M
IT
TE
D
D E
S
IG
N E
D
R E
V
IE
W E
D
C H
A
N C
H
C H
C
TI
O
N
U.
S.
A
RM
Y
EN
GI
NE
ER
D
IS
TR
IC
T
AN
CH
O
RA
G E, A
LA
SK
A
CO
RP
S O
F
EN
G
IN
EE
RS
REFERENCE
NUMBER:
SHEET OF
US ARMY CORPS
OF ENGINEERS
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10 11 12 D ra w in g
X :\U
N
IF
IE
D
\E N
-C W
\J ob s\ S
E W
6\
D w gs
\C A
D \S
E W
6-
-S
-2
.d w g la st s av ed o n
5/
/2
:2
A M w as p lo tte d by T ed ric k, R ob er t C P
O A on
/1 7/
1:
A
W -9
3-
-0
S E
W
P
N
O . 1
W
1K B
-1 6-
R -0
M A
Y
AM#3
LO
W
E
LL
C R
E E
K T
U N
N E
L R
E P
A
IR
S S
E W
A R
D , A
LA
S
AutoCAD SHX Text
AutoCAD SHX Text
18 MAY 2016
AutoCAD SHX Text
AM#3
AutoCAD SHX Text
CORRECT DETAIL CALLOUT
AutoCAD SHX Text
RCT
AutoCAD SHX Text
AutoCAD SHX Text
SIDE WALL ARMOR ANCHORS AT ENDS
SCALE: 1 1/2" = 1'-0"
A S-201 S-501
AXIS
6"
CL OF TOP ARMOR
RAIL MATCHES ELEV
OF TUNNEL HOR AXIS
2" ±GROUTING
VENT TUBE
GROUTING
VENT TUBE
GROUT
TUBE
TEMPORARY
BULKHEAD FOR
GROUTING. TYPICAL
AT TOP, BOTTOM
AND ENDS AS REQ'D.
MECHANICALLY ROUGHEN
ALL SURFACES TO
RECEIVE GROUT OR CONC
TO A FULL 14" PROFILE, TYP
NOTES:
1. TACK WELD 12 GA STRIPS OF
STEEL SHEET TO BACK SIDE OF
BASE OF RAILS TO CONTAIN
GROUT, TYPICAL
2. SEE B/S-501 FOR SIM DETAILS
NOT SHOWN.
4" Ø x 36" L ANCHORS IN 11
2"
MIN Ø HOLES, SEE C/S-501
60 - 85 LB/YD ASCE RAILS, ONE
SIZE ONLY, CONTRACTOR'S
CHOICE, 85 LB/YD SHOWN
4" x 8" ANCHOR
PLATE, SEE A/S-502
10,000 PSI SILICA-FUME SHOTCRETE,
PLACED TO FACE OF RAILS WHICH
SHALL BE PLACED TO MATCH THE
ORIGINAL TUNNEL WALL PROFILE, FINAL
FINISH SHALL BE WOOD FLOATED PER
THE SPECIFICATIONS.
(E) RAILS TO
REMAIN, WHERE
PRESENT
FILL (E) CAVITY W/
10,000 PSI
SILICA-FUME
CONCRETE TO
BACK FACE OF NEW
GROUT
PLACEMENT, TYP
SIDE WALL ARMOR ANCHORS BETWEEN ENDS
SCALE: 1 1/2" = 1'-0"
B S-501 S-201 S-501
AXIS
6"
CL OF TOP ARMOR
RAIL MATCHES ELEV
OF TUNNEL HOR AXIS
2" ±GROUTING
VENT TUBE
GROUTING
VENT TUBE
GROUT
TUBE
TEMPORARY
BULKHEAD FOR
GROUTING. TYPICAL
AT TOP, BOTTOM
AND ENDS AS REQ'D.
4" Ø x 36" L ANCHORS IN 11
2"
MIN Ø HOLES, SEE C/S-501
60 - 85 LB/YD ASCE RAILS, ONE
SIZE ONLY, CONTRACTOR'S
CHOICE, 85 LB/YD SHOWN
4" x 8" ANCHOR
PLATE, SEE A/S-502
FOR TYPICAL RAIL
CLIP, SEE B/S-502
NON-SHRINK GROUT, NOMINALLY 11
2"
THICK FROM BASE OF RAILS
(E) CONC TUNNEL LINING REMOVED AS
REQD FOR GROUT PLACEMENT, OR
NEW CONC @ WALL CAVITY PLACED
TO COMPLETELY FILL CAVITY AND
ALLOW FOR REQD GROUT PLACEMENT.
SPACER AS REQD
UNDER WASHER @
ENDS OF ANCHOR
PLATE, TYPICAL(E) RAILS TO
REMAIN, WHERE
PRESENT
ANCHOR PLATE DETAIL
SCALE: 3" = 1'-0"
C S-501 S-201S-501
11" @
RIGHT END
S
TA
+1
(E) 70 LB/YD RAILS FILLED
BETWEEN W/ ANVIL-TOP,
SHOWN W/0 WEAR
NEW WALL
RAILS, SQ CUT
ENDS AND
BUTT INTO (E)
WALL RAILS
REMOVE (E)
CONC AS REQD
FOR NEW WALL
RAIL
INSTALLATION
(E) CONC TUNNEL
LINER OR NEW
CONC @ CAVITY
(E) NON-SHRINK
GROUT FROM
1984 REPAIRS
~ 112" NEW
NON-SHRINK
GROUT
STEEL SHIMS, THK AND
SPACING AS REQD TO
BRING ANCHOR PLATE
INTO ALIGNMENT
ANCHOR GROUTED
INTO CONC AND ROCK
SQ PL WASHER
NOTES:
1. PL WASHERS SHALL BE MIN
212" SQ AND MIN 516" THK
2. CONC FILL BETWEEN RAILS
NOT SHOWN FOR CLARITY
3. DETAILS ARE SIMILAR AT
ANCHORS BETWEEN ENDS
ANCHOR PLATE DETAIL
SCALE: 3" = 1'-0"
D S-201 S-501
4" @
LEFT END
S
TA
+5
NEW WALL
RAILS W/ SQ
CUT ENDS
(E) CONC
TUNNEL
LINER
NOTES:
1. SEE C/S-501 FOR SIMILAR
DETAILS NOT SHOWN
3"
MIN
E X
C A
V A
TE
C
O N
C R
E
TE
ANCHOR PLATE DETAIL FOR SPLICED RAILS
SCALE: 3" = 1'-0"
E S-201 S-501
11"
S P
LI
C
E
NEW WALL
RAILS, TYP,
SQ CUT ENDS
REMOVE (E)
CONC AS REQD
FOR NEW WALL
RAIL
INSTALLATION
(E) CONCRETE
TUNNEL LINER
~ 112" NEW
NON-SHRINK
GROUT
STEEL SHIMS, THK AND
SPACING AS REQD TO
BRING ANCHOR PLATE
INTO ALIGNMENT
ANCHOR GROUTED
INTO CONC AND
ROCK, TYPICAL
SQ PL WASHER, TYP
NOTES:
1. SEE C/S-501 FOR SIMILAR
DETAILS NOT SHOWN
4"
SEQUENCE OF WALL CAVITY REPAIR WORK:
1. FILL (E) CAVITY W/ CONCRETE AS REQ'D
2. DRILL HOLES FOR AND GROUT IN ANCHOR RODS
TO PROPER ALIGNMENT
3. MOUNT AND SHIM ANCHOR PLATES AS REQ'D
4. MOUNT AND ALIGN RAILS USING ANCHOR ROD
WASHERS AND NUTS AS WELL AS RAIL CLIPS
5. PLACE GROUT RETAINING STRIPS AND
BULKHEADS AS REQ'D
6. PRESSURE GROUT CAVITY BEHIND RAILS
7. SHOTCRETE AND FINISH TO MATCH ORIGINAL
PROFILE AND BLEND WITH ADJACENT
CONCRETE SURFACES.
1:
S E
W
6-
-S -5
D E
TA
IL
S
S-501
R
IG
H T
S
ID
E W
A
LL
C A
V
IT
Y R
E P
A
IR
D E
TA
IL
S I
A S
N O
TE
D
C E
P O
A -E
C -G
D.
B
LI
SS
E C
-G -H
HK.
E
IS
SE
S
RC
T
RC
T
S
TR
U C
TU
R
A L
ALASKA DISTRICT
D R
A W
IN
G
FI
LE
D W
G S
C A
LE
P
LO
T S
C A
LE
D A
TE
A C
TI
O
N S
Y M
D R
A W
N
R E
S
ID
E N
T E
N G
IN
E
E R
D A
TE
S
TA
TE
P R
IM
E
C O
N
TR
A C
TO
R
D A
TE
D
E S
C R
IP
TI
O N
A P
P D
C
IT
Y
C O
N
TR
A C
TO
R
C O
N
TR
A C
T N
O
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
S U
B M
IT
TE
D
D E
S
IG
N E
D
R E
V
IE
W E
D
C H
A
N C
H
C H
C
TI
O
N
U.
S.
A
RM
Y
EN
GI
NE
ER
D
IS
TR
IC
T
AN
CH
O
RA
G E, A
LA
SK
A
CO
RP
S O
F
EN
G
IN
EE
RS
REFERENCE
NUMBER:
SHEET OF
US ARMY CORPS
OF ENGINEERS
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10 11 12 D ra w in g
X :\U
N
IF
IE
D
\E N
-C W
\J ob s\ S
E W
6\
D w gs
\C A
D \S
E W
6-
-S
-5
.d w g la st s av ed o n
5/
/2
:1
P M w as p lo tte d by T ed ric k, R ob er t C P
O A on
/1 7/
2:
P
W -9
3-
-0
S E
W
P
N
O . 1
W
1K B
-1 6-
R -0
M A
Y
AM#3
LO
W
E
LL
C R
E E
K T
U N
N E
L R
E P
A
IR
S S
E W
A R
D , A
LA
S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
18 MAY 2016
AutoCAD SHX Text
AM#3
AutoCAD SHX Text
(1) DELETE DETAIL REFERENCE CALLOUT
AutoCAD SHX Text
RCT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
18 MAY 2016
AutoCAD SHX Text
AM#3
AutoCAD SHX Text
(2) ADD SECTION REFERENCE CALLOUT
AutoCAD SHX Text
RCT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
| Sheets and Views |
| G-003 GENERAL NOTES AND ABBREVIATIONS |
| S-201 RIGHT SIDE WALL CAVITY REPAIR |
| S-501 RIGHT SIDE WALL CAVITY REPAIR DETAILS I |
File details come from the government source that posted it. Updated .