The document addresses two primary inquiries from potential contractors. First, it clarifies that Grade One material is required for both keys and cores. Second, it specifies keyway requirements by referencing the Statement of Work Part 4, Section 4.2, Task 2. According to the referenced SOW provisions, keys must be cut on J, K, and M keyways as specified in the contract documentation. Master and control keys require quad-milled cuts on J, K, L, and M operating keys. The response indicates that keyway specifications are detailed in the underlying SOW and that contractors should consult that document for complete cutting specifications and other technical requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Q&A for W91151-26-Q-A044 Keys and Cores

Q1. Can you please confirm what grade of material these keys require? I tried pinpointing in the documentation but could not find that.

A1. Grade one for keys and cores.

Q2. We will need the keyway to be able to do this. There are a lot of Best brand keyways.

The keyway is needed. It is the cut on the back of the key.

A2. Per the statement of work part 4 specific tasks 4.2 task 2 bullet three Keyway:

Keys shall be cut on J, K, and M keyways as specified. Master and control keys shall be cut on a quad- milled J, K, L and M operating key.