TE G - Sectional Chain Gear Driven Doors.xlsx

XLSX spreadsheet 13 KB Posted

Attached to
Overhead Doors Federal contract opportunity
Solicitation number
W91151-19-R-0016
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Hood

About this file

This sources sought notice seeks capabilities statements from interested parties for overhead doors preventative maintenance, repair, and replacement services at Fort Hood, Texas. The Army Materiel Command Mission and Installation Contracting Command is considering setting aside this requirement for small businesses. Interested parties should provide company and point of contact information; whether proposing as a prime contractor or subcontractor; experience with similar requirements; commercially available pricing for the services; and recommendations on structuring the requirement to facilitate small business competition by March 29, 2019. The previous contract for these services was awarded in 2014.

Sectional Chain Gear Driven Doors.xlsx

View the file

Other files for this federal contract opportunity

Other files attached to Overhead Doors, newest first.
File Type Posted
TE N - Hazardous Material Request.xlsm XLSM spreadsheet
TE E - Sectional Chain Driven Doors.xlsx XLSX spreadsheet
TE M - Hangar Sectional Gear Driven Doors.xlsx XLSX spreadsheet
TE J - Sectional Gear Driven Doors.xlsx XLSX spreadsheet
TE F - Hanger Manual Doors.xlsx XLSX spreadsheet
TE P - Contract for Sale of Utilities.doc DOC document
TE C - Rolling Steel Manual Doors.xlsx XLSX spreadsheet
TE D-1 - Rolling Steel Chain Gear Driven Doors.xlsx XLSX spreadsheet
TE B - Rolling Steel Chain Driven Doors.xlsx XLSX spreadsheet
TE K - Hanger Chain Gear Driven Doors.xlsx XLSX spreadsheet
TE_G_-_Sectional_Chain_Gear_Driven_Doors.zip ZIP file
TE H - Sectional Manual Doors.xlsx XLSX spreadsheet
PWS_Overhead_Doors_W91151-14-C-0058_FH_6_MARCH_2019.pdf PDF
TE L - Hanger Gear Driven Doors.xlsx XLSX spreadsheet
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

TECHNICAL EXHIBIT G SECTIONAL CHAIN/GEAR DRIVEN DOOR
Building NumberAddressNumber of DoorsDoor NumbersSize of DoorsInsulated or Non InsulatedSlat TypeManufacturerRemarks
17009HOW & 42nd177111'6"x8'Non InsulatedSectionsRaynor
52940Tank Destroyer & Muskogee62827-283214'2x14'7InsulatedSections T&GDasma
88027Clarke Rd. & Logistics82917-292419'6x20'3, 22'1x18'6, 19'6x23'8, 20'10x21, 20'10x18'7& 26'2x21Non InsulatedVertical SectionsDoorman
90017Clarke Rd (WFH)32610-261214'2x13'6 & 14'2x17'2 & 12'2x13'6Non Insulated14'2x2 Sections & 12'2x2 sectionsRaynor
90023Clarke Rd (WFH)32613-261512'2x12Non Insulated12'2x2 SectionsRaynor
90052Gray Drive (WFH)32728-273014'2x14Non InsulatedShip Lap SectionsOverhead
9012082957-296420"x14"InsulatedSectionalLoverhead DoorNew to TE
92074Supply Rd, WFH1276810'2x10InsulatedSectionsLiftmaster