TE F - Hanger Manual Doors.xlsx
XLSX spreadsheet 13 KB Posted
- Attached to
- Overhead Doors Federal contract opportunity
- Solicitation number
- W91151-19-R-0016
About this file
This sources sought notice requests capability statements from small businesses for overhead doors preventative maintenance, repair, and replacement services at Fort Hood, Texas. Interested parties are requested to provide company information and details on relevant experience by March 29, 2019. The Army seeks to set aside this requirement for small businesses and encourages responses from 8(a), small disadvantaged, HUBZone, service-disabled veteran-owned, and women-owned small businesses. The work involves maintenance and repair of manual and automatic doors across various buildings, and was previously awarded in 2014 under contract number W91151-14-C-0058. Respondents are asked to propose how the Army can best structure this requirement to facilitate small business competition.
Hanger Manual Doors.xlsx
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| TE J - Sectional Gear Driven Doors.xlsx | XLSX spreadsheet | |
| TE B - Rolling Steel Chain Driven Doors.xlsx | XLSX spreadsheet | |
| TE G - Sectional Chain Gear Driven Doors.xlsx | XLSX spreadsheet | |
| TE K - Hanger Chain Gear Driven Doors.xlsx | XLSX spreadsheet | |
| TE_G_-_Sectional_Chain_Gear_Driven_Doors.zip | ZIP file | |
| TE H - Sectional Manual Doors.xlsx | XLSX spreadsheet | |
| PWS_Overhead_Doors_W91151-14-C-0058_FH_6_MARCH_2019.pdf | ||
| TE L - Hanger Gear Driven Doors.xlsx | XLSX spreadsheet | |
| TE N - Hazardous Material Request.xlsm | XLSM spreadsheet | |
| TE E - Sectional Chain Driven Doors.xlsx | XLSX spreadsheet | |
| TE M - Hangar Sectional Gear Driven Doors.xlsx | XLSX spreadsheet | |
| TE P - Contract for Sale of Utilities.doc | DOC document | |
| TE C - Rolling Steel Manual Doors.xlsx | XLSX spreadsheet | |
| TE D-1 - Rolling Steel Chain Gear Driven Doors.xlsx | XLSX spreadsheet |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| TECHNICAL EXHIBIT F HANGAR MANUAL DOOR | ||||||||
| Building Number | Technical Exhibit | Address | Number of Doors | Door Numbers | Size of Doors | Insulated or Non Insulated | Slat Type | Manufacturer |
| 135 | F | 761st Tank Batallion &42nd | 1 | 2999 | 12'2x8 | Non Insulated | Sections T & G | N/A |
| 224 | F | 761st Tank Batallion & 37th | 14 | 2791-2800 & 1714-1717 | 10'2x10'2 | Non Insulated | Sections | Finishline |
| 1953 | F | North Ave & 37th | 1 | 875 | 8'2"x8" | Non Insulated | 8'2"x2" sections | N/A |
| 4407 | F | Warehouse & 65th | 2 | 2290-2291 | 8'2x10' | Non Insulated | Sections | N/A |
| 4410 | F | Warehouse & 68th | 1 | 2288 | 8'5x8 | Insulated | Sections | N/A |
| 707 | F | Murphy Rd. (HAA) | 6 | 1744-1749 | 10'3.5XX24 & 10'2X24 | Non Insulated | Hanger | N/A |
| 708 | F | Murphy Rd. (HAA) | 6 | 1751-1756 | 10'2x23'5 | Non Insulated | Hanger | N/A |
| 7007 | F | Murphy Loop (HAA) | 16 | 1726-1741 | 16'6 1/2X 26'8 1/2 | Non Insulated | Hanger | N/A |
| 7012 | F | Murphy Loop (HAA) | 12 | 1701-1712 | 27'x27' 1/2" | Non Insulated | Hanger | N/A |
| 7037 | F | Murphy Loop (HAA) | 1 | 1637 | 12'2x10'2 | Insulated | Sections | Windsor |
| 9134 | F | HOW & 19TH | 4 | 1295-1298 | 11'6X8' | Non Insulated | Sections | N/A |
| 9542 | F | HOW & 16th | 1 | 962 | 11'6X8' | Non Insulated | sections T & G | N/A |
| 17021 | F | HOW & 42nd | 1 | 739 | 11'6"x8' | Non Insulated | Sections | N/A |
| 25030 | F | HOW & 58TH | 1 | 570 | 12'2"X10' | Non Insulated | 12'2"X2" Sections | Windsor |
| 30023 | F | HOW & 67th | 2 | 446-447 | 11'6x8' | Non Insulated | 11'6"x2' Sections | N/A |
| 35015 | F | How & 73rd | 2 | 0217-0218 | 11'6"X8' | Non Insulated | 11'6"x2' Sections Ship Lap | N/A |
| 35022 | F | HOW & 73rd | 2 | 186 & 219 | 11'6x8' | Non Insulated | 11'6"x2' Sections T&G | N/A |
| 38002 | F | HOW & 75TH | 2 | 0127-0128 | 11'6"X8' | Non Insulated | 11'6"x2' Sections | N/A |
| 38022 | F | HOW & 75th | 2 | 84-85 | 11'6X8' | Non Insulated | Sections | N/A |
| 38062 | F | HOW & Clear Creek | 2 | 28-29 | 11'7x8 | Non Insulated | 24"Sections | N/A |
| 52378 | F | Clear Creek Golf Course | 1 | 566 | 10'2x8 | Non Insulated | Sections | Windsor |
| 52386 | F | Clear Creek Golf Course | 1 | 567 | 12'2x12 | Non Insulated | Sections | N/A |
| 56326 | F | 18th & Ave F (NFH) | 3 | 2781-2783 | 10'2x11'2 | Non Insulated | Sections | Killeen overhead |
| 88001 | F | Clarke Rd. & Logistics | 2 | 2299-2300 | 12'2X10 | Non Insulated | Sections | N/A |
| 90133 | F | Clarke Rd & Mowhawk Rd (WFH) | 2 | 1879-1880 | 14'2x14 | Non Insulated | Sections 14'2x2 | N/A |
| 91058 | F | Warehouse Ave, WFH | 2 | 2600-2601 | 11'10x11'10 | Non Insulated | Section Ship Lap | N/A |
| 92045 | F | Supply Rd & Loop Rd (WFH) | 1 | 2756 | 10'2x14 | Non Insulated | Sections | N/A |
| 51 |