This document includes a technical exhibit outlining rolling steel manual door specifications for various buildings and a related federal contract opportunity solicitation. The technical exhibit provides details on 14 rolling steel manual doors for different buildings, including address, number of doors, door sizes, insulation type, slat type, and manufacturer. The related federal contract opportunity is a solicitation from the Department of the Army Materiel Command Mission and Installation Contracting Command at Fort Hood, Texas to provide overhead doors preventative maintenance services for the Fort Hood installation. The contractor will be responsible for performing overhead door services to the standards specified in the performance work statement on a non-personal services basis.
View the file
Other files for this federal contract opportunity
Show all 26
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| TECHNICAL EXHIBIT C ROLLING STEEL MANUAL DOORS | |||||||||
| Building Number | Technical Exhibit | Address | Number of Doors | Door Numbers | Size of Doors | Insulated or Non Insulated | Deleted Buildings | Slat Type | Manufacturer |
| 1156 | C | HOW & 27 | 1 | 1105 | 8'2 3/4X8' | Non Insulated | Curved | N/A | |
| 1938 | C | Rod & Gun Club Lp | 1 | 2930 | 8' 3" X 6'8 | Non Insulated | Curved | DBCI | |
| 1944 | C | Rod & Gun Club Lp | 2 | 0668-0669 | 10'4"x10' | Non Insulated | Curved | Provene | |
| 2205 | C | Support Ave & 58th | 3 | 2084-2086 | 8'4x8'2 | Non Insulated | Flat 2 3/4 | N/A | |
| 4208 | C | Warehouse & 77th | 4 | 963-965 & 967 | 8'11.5x7'6 | Non Insulated | Delete | Curved | Southwestern |
| 4209 | C | Warehouse & 77th | 1 | 2224 | 8'11 1/2"x7'8 | Non Insulated | Delete | Curved | Overhead Door |
| 4224 | C | Tank Destroyer & 78th | 1 | 2218 | 9'1x7'7 | Non Insulated | Delete | Curved | Windsor |
| 4225 | C | Tank Destroyer & 78th | 2 | 2220-2221 | 9'1x7'7 | Non Insulated | Delete | Curved | Windsor |
| 4252 | C | Tank Destroyer & 79th | 4 | 2161-2164 | 8'7x7 & 8'10x9 & 8'10x7 | Non Insulated | Delete | Flat | Southwestern |
| 4401 | C | Warehouse & 77th | 1 | 2247 | 8'9x8 | Non Insulated | Delete | Curved | Provene |
| 4410 | C | Warehouse & 68th | 1 | 2248 | 8'5x8'5 | Insulated | Delete | Flat 2 3/4 | N/A |
| 4480 | C | Warehouse | 1 | 3104 | 7'1x7 | Non Insulated | Delete | Curved | N/A |
| 91061 | C | Warehouse Rd (WFH) | 1 | 2597 | 12'3x8 | Non Insulated | Full Curtain | Roll Rite Ind | |