320257_DWG_MECH.pdf

PDF 2 MB Posted

Attached to
Installation of Tent for DFAC on Camp Hovey (MATOC Only)
Solicitation number
W90VN824R0064
Issued by

About this file

This document is a set of mechanical plans and specifications for the installation of a temporary dining facility (DFAC) tent on Camp Hovey. The key details include:

The scope of work includes civil work (sewer, water, sidewalks, paving), architectural work (installing the 55m x 20m tent, doors, partitions, flooring), mechanical work (relocating existing DFAC kitchen equipment to the tent, installing new dishwashing and prep equipment), and electrical work (lighting, exit signs, emergency power). The contractor must complete all work within a 75-day construction period. The federal agency involved is the Department of the Army Materiel Command Army Contracting Command. This solicitation is only open to MATOC contract holders.

View the file

Other files

File Type Posted
UPDATED 320257_INSTALLATION TENT_CP-HOVEY_DWG_ARCH.pdf PDF
Amendment W90VN824R0064-0001.pdf PDF
320257_DWG_ARCH.pdf PDF
320257_DWG_CIVIL.pdf PDF
W90VN824R0064_KO SIGNED.pdf PDF
320257_DWG_TITLE-SHEET.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

M-1

MECHANICAL

M E C H A N I C A L M A T E R I A L I N D I C A T I O N S & S Y M B O L S

NTS

PD

Pa

OS&Y

OXY

OD

OAIL

OA

QT

PRV

PPM

POL

POC

PLMB

PH

PG

RT

RPM

RH

RDTR

RA

R12, R22

QTY

A B B R E V I A T I O N S

SBM

SAN

SA

SCH

FLOWMETER, ORIFICEBUTTERFLY

REFRIGERANT LIQUID

CHILLED WATER SUPPLY

CHILLED WATER RETURN

AIR COOLED CONDENSING UNIT

AIR CONDITION UNIT (S)

APPARATUS DEW POINT

AIR CONDITION (-ING,-ED)

CHILLED/HOT WATER RETURN

AMERICAN WIRE GAUGE

PRESSURE, BAROMETRIC

CUBIC METER PER HOUR

CHILLED/HOT WATER SUPPLY

CAPACITYCAP

CONNECTION

CONTINUE

COMPRESSOR

CUBIC METER

CPRSR

CONN

CONT

CU M

CHILLED WATER

CAST IRON PIPE

CIRCUIT

CLASSIFICATION

COOLING LOAD

COEFFICIENT

COUNTER CLOCKWISE

CLASS

CLG LOAD

COEF

CMH

CIP

CCW

CHW

CKT

ACV ALARM CHECK VALVE

AVERAGEAVG

BOILING POINT

CENTIGRADE

BAROMETER(-TRIC)

BRAKE HORSEPOWER

BP

BHP

C

BARO PR

AWG

BARO

ALUMINUM

ALTITUDE

AMBIENT

AIR HANDLING UNIT

AMPERE(AMP, AMPS)

APPROXIMATEAPPROX

ALT

AMB

AMP

AIR COND

ADP

AL

AHU

AIR COOLED

ACCU

ACLD

ACU

CHR

C/HWR

C/HWS

CHS

RL

D DRAIN

DIAMETER, INSIDE

ISOMETRIC

IRON PIPE SIZE

JOULE

THERMAL CONDUCTIVITY

KILOGRAM

KILOGRAM PER SQ. CENTIMETER (GAUGE)

KILOGRAM PER SQ. CENTIMETER

KILOGRAM PER SQ. CENTIMETER (ABSOLUTE)

KILOCALORIE PER HOUR

EXPANSION JOINT

EXPLOSION PROOF

FIRE HOSE CABINET

FULL LOAD AMPERES

ENTERING WATER TEMP

EVAPORAT (-E,-ING,-ED,-OR)

EXTERNAL STATIC PRESSURE

FACE AREA OR FRESH AIRFA

FHC

FHY

FLA

FIRE HYDRANT

ESP

EXPJT

EWT

EVAP

EP

EQPT

ENT

EFF

EQUIPMENT

ENTERING

EFFICIENCY

KG/SQ CM

KG/SQ CM A

KG/SQ CM G

KG

KCAL/HR

J

K

ID

ISO

IPS

NO

N.O.

NIC

NPT

MPS

NC

N/A

N.C.

MAX

MIN

MPH

MM

NOT IN CONTRACT

NATIONAL TAPER PIPE (THREAD)

NUMBER

NORMALLY OPEN

MINIMUM OR MINUTE

METERS PER HOUR

METERS PER SECOND

NORMALLY CLOSED

NOISE CRITERIA

NOT APPLICABLE

MAXIMUM

MILLIMETER R

FEMALE PIPE THREAD

FUEL OIL

GALVANIZED STEEL

GAGE OR GAUGE

FIXTURE

FEED WATER PUMP

FACE VELOCITY

FLUSH VALVE

FREQUENCY

FIBERGLASS REINFORCED PLASTIC

HORIZONTAL

HOT WATER HEATER

HOT WATER

HOUR(S)

HORSEPOWER

MERCURY

HEAD

HOSE BIBB

HERTZ

GRAMS

FRPCWP CIRCULATING WATER PUMP

DIRECT EXPANSION

DRY PIPE VALVE

EQUIVALENT DIRECT RADIATION

ENTERING AIR TEMPERATURE

DOUBLE POLE DOUBLE THROW

DEWPOINT TEMPERATURE

DRY BULB TEMPERATURE

DECIBEL OR DRY BULB

DIESEL OILDO

ECON

ECC

EAT

EDR

DX

DPV

DPDT

DPT

ECONOMIZER

ECCENTRIC

o

DIFF

DIAG

DIA or

DIV

DBT

DB

DIFFERENCE

DIAGRAM

DIAMETER

DIVISION

DEGREE

HR

HORIZ

HWH

HW

HZ

HP

HG

HD

HB

GALVS

GA

GR

FXTR

FWP

FVEL

FV

CUBIC MILLIMETER

CLOCKWISE OR COLD WATER

COEFFICIENT, VALVE FLOWCv

CU MM

CW

PLUG VALVE

THREE WAY

FPT

FO

FREQ

GATE, ANGLE

GATE, GLOBE

GLOBE

GATE

CONTROL

KJ KILOJOULE

LH

LT

LWT

LPS

M

LL

LPD

LPH

LM

LAV

LAT

LBS

LG

KW

KWH

L

LATENT HEAT

LEAVING WATER TEMPERATURE

LITERS PER HOUR

LITERS PER SECOND

LAUNDRY TRAY

METERS

LIQUID LINE

LITERS PER DAY

LINEAR METER

LEAVING AIR TEMPERATURE

LAVATORY

POUNDS

LENGTH

KILOWATT

KILOWATT HOUR

LITERS

P

FLOWMETER, VENTURI

FLOW SWITCH

PRESSURE SWITCH

PRESSURE GAUGE AND COCK

PUMP (INDICATE USE)

STRAINER

STRAINER, BLOW OFF

KG/SM

KG/SM A

KG/SM G

PS

P

OFM

FS

VFM

KILOGRAM PER SQ. METER

KILOGRAM PER SQ. METER (ABSOLUTE)

KILOGRAM PER SQ. METER (GAUGE)

JACKET WATER RETURN

MEDIUM PRESSURE STEAM

MEDIUM PRESSURE CONDENSATE

LOW PRESSURE STEAM

LOW PRESSURE CONDENSATE

BOILER BLOW DOWN

PUMPED CONDENSATE

JACKET WATER SUPPLY

VACUUM PUMP DISCHARGE

FUEL OIL TANK VENT

CONDENSATE WATER SUPPLY

CONDENSATE WATER RETURN

MEDIUM TEMPERATURE HOT WATER SUPPLY

MEDIUM TEMPERATURE HOT WATER RETURN

LOW TEMPERATURE HOT WATER SUPPLY

LOW TEMPERATURE HOT WATER RETURN

PIPE TO BE REMOVED

REFRIGERANT DISCHARGE

REFRIGERANT SUCTION

LPS

CONTROL AIR MAIN

air conditioning and refrigeration

RD

RS

(NAME)E

(NAME)

M

EXISTING PIPE

COMPRESSED AIR

VACUUM (AIR)

HWR

VAC

A

MTWS

MTWR

HWS

FOD FUEL OIL DRAIN

FOR

CS

CR

FOV

FOG

FOS FUEL OIL SUPPLY

FUEL OIL RETURN

FUEL OIL GAUGE

PC

VPD

MU

LPC

BBD

MAKE UP WATER

MPS

MPC

JWR

JWS

heating

PIPING

CHECK, SWINGSANITARY DRAIN

PITCH OR PIPE, UP(U), DOWN(D)

FLOOR SINK (200mm x 200mm)

PIPE SLEEVE WITH FIRE STOPPING

VENT THRU ROOF

BFP

valves : (for selective actuators)

PLAN

HOSE BIBB

AIR LINEA

BALL

ELEV.

BACKFLOW PREVENTER

PIPE SLEEVE

(NAME)

ACID

200mm x 200mm

SURFACE CLEANOUT

FLOOR CLEANOUT

FLOOR DRAIN

CHEMICAL SUPPLY PIPES

FUNNEL DRAIN, OPEN

FCO

FD

SCO

FLOOR OR GRADE

FLOOR OR GRADE

CONDENSATE DRAIN BELOW

CONDENSATE DRAIN ABOVE

ACID WASTE

GASG

CD

CD

AIR VENT, MANUAL

AIR VENT, AUTOMATIC

W/ MEASURING TAP

EXPANSION LOOP

EXPANSION JOINT

BALL JOINT

ANCHOR, MAIN

ANCHOR, INTERMEDIATE

ALIGNMENT GUIDE

AIR SEPARATOR

FLEXIBLE CONNECTOR

SQUARE HEAD BALANCING COCK

EJ

S

MV

AVV

CHECK, NON-SLAM

CONTROL, ELECTRIC-PNEUMATIC

CONTROL, PNEUMATIC-ELECTRIC

QUICK OPENING

PRESSURE REDUCING

NEEDLE

LOCK SHIELD

HOSE END DRAIN

SAFETY

RELIEF

SQUARE HEAD BALANCING COCK

QUICK CLOSING, FUSIBLE LINK

R

S

PE

EP

plumbing

COLD WATER

HOT WATER RETURN

HOT WATER SUPPLY

VENT

MOTOR ELECTRIC

DIAPHRAGM

valves, special duty :

SOLENOIDS

valve actuators

M

FDAD

SUCTIONQUANTITY SUCT

TONS OF REFRIGERATION

TEMPERATURE DIFFERENCE

HEAT TRANSFER COEFFICIENT

SANITARY

SUBMERSIBLE

SUPPLY AIR

SCHEDULE

RADIATOR

REFRIGERATION TON

REVOLUTIONS PER MINUTE

RELATIVE HUMIDITY

RETURN AIR

THERMAL RESISTANCE

REFRIGERANT (12, 22, ETC)

TYPICALTYP

URINAL

UNIT HEATER

UR

UH

U

THERMOSTAT

THICKNESS

THERMOMETER

TEMPERATURE

SYMBOL

TSTAT

TONS

THERM

THK

TEMP

TD

SYM

SINGLE POLE DOUBLE THROW

LPH, STANDARD CONDITIONS

LPS, STANDARD CONDITIONS

LPD, STANDARD CONDITIONS

SAYBOLT SECONDS UNIVERSAL

SAYBOLT SECONDS FUROL

SENSIBLE HEATOUTSIDE AIR INTAKE LOUVER SH

PRESSURE DROP OR DIFFERENCE

PRESSURE REDUCING VALVE

PHASE (ELECTRIC)

PERCENT

PARTS PER MILLION

POINT OF CONNECTION

PLUMBING

PETROLEUM, OIL AND LUBRICANTS

QUART

OUTSIDE SCREW & YOKE

DIAMETER, OUTSIDE

PRESSURE GAGE

POLE

PASCAL

OXYGEN

SPRINKLERSPR

STEEL

STANDARD

STEAM

SQUARE

STAINLESS STEEL

STORAGESTOR

STL

STD

ST

SSU

SST

SSF

SQ

SENSIBLE LOAD

STATIC PRESSURE

SQUARE METER

SPECIFICATION

SPDT

SPEC

SM

SP

SLPH

SLPS

SLPD

SL

ALARM CHECK VALVE

SIDEWALL SPRINKLER

PENDENT SPRINKLER

UPRIGHT SPRINKLER

FIRE DEPARTMENT CONNECTION

PRE-ACTION VALVE

NOT TO SCALE

OUTSIDE AIR

(2-WAY SHOWN)

DRY-PIPE VALVE

SECOND

SAFETY FACTOR

SPECIFIC GRAVITYSG

SF

SEC

VARIABLE AIR VOLUMEVAV

VENTILATION

PRESSURE, DYNAMIC(VELOCITY)

WATER-COOLED

WATER CLOSET

WATTHOUR OR WATER HEATER

WET BULB TEMPERATURE

WATERPROOF

WSHR

WCLD

WTRPRF

WH

WT

W/

WD

WC

WBT

WEIGHT

WITH

WASHER

WIDTH

VP

VOL

WB

W

VISC

VERT

VENT

VEL

VOLUME

WET BULB

WATT

VISCOSITY

VERTICAL

VELOCITY

MANUAL VOLUME DAMPER

SMOKE DAMPER (PROVIDE ACCESS DOOR)

PNEUMATIC OPERATED DAMPER

VLV

V

VAC

M

VALVE

VOLT

VACUUM

SPLITTER DAMPER

SD

AD

VD

grilles, registers and diffusers :

SG

SR

600/300

300x150

200mm NCD

FIGURE IS ON TOP

810mm x 400mm dampers

ELBOW, TURNED DOWN

REDUCER, CONCENTRIC

REDUCER, ECCENTRIC (STRAIGHT, INVERT)

REDUCER, ECCENTRIC (STRAIGHT, DOWN)

TEE, OUTLET DOWN

TEE, SINGLE SWEEP

sprinkler

UNION, SCREWED

UNION, FLANGED

TEE, OUTLET UP

TEE

LATERAL

CONNECTION, BOTTOM

CONNECTION, TOP

ELBOW, TURNED UP

BUSHING

CAP

WELDED

FLANGED

SOLDERED

SCREWED BELL AND SPIGOT

SOLVENT CEMENT

SOUND ATTENUATOR

DETECTORS, FIRE AND/OR SMOKE

ELECTRIC MOTOR OPERATED DAMPER

FIRE DAMPER (PROVIDE ACCESS DOOR)

BACKDRAFT DAMPER

BDD

S

TRANSITION

TURNING VANES

SF

CHANGE OF ELEVATION, RISE(R), DOWN(D)

DUCT SECTION, NEGATIVE PRESS., FIRST

ACCESS DOOR, VERTICAL OR HORIZONTAL

COWL, (GOOSENECK) AND FLASHING

ACOUSTICAL LINING

FLEXIBLE DUCT

FLEXIBLE CONNECTIONFC

FIGURE IS ON TOP

R

AD

47.2

TG

94.4

UC 13mm

DG

500/300L

DUCT WORK

810mm x 400mm

810mm x 400mm

THERMOSTAT, ELECTRIC

TRAP, ELECTRIC (INDICATE TYPE)

fitting :

R

THERMOMETER

EXHAUST AIR GRILLE OR REGISTER, CEILING

DUCT SECTION, POSITIVE PRESS., FIRST

DIRECTION OF FLOW

SR

DIFFUSER, LINEAR

RETURN AIR GRILLE OR REGISTER, CEILING

CEILING DIFFUSER, SQUARE TYPE

CEILING DIFFUSER, ROUND TYPE (200mm

(600mm x 300mmH, 472 LPS)

UNDERCUT DOOR (13mm, 47.2 LPS)

DOOR GRILLE (300mmx150mmH)

NECK DIAMETER)

TRANSFER GRILLE ASSEMBLY

LOUVER, DOOR OR WALL

(500mmWx300mmH, 94.4 LPS)

RG

RR

SUPPLY AIR GRILLE OR REGISTER, SIDEWALL

EXHAUST AIR GRILLE OR REGISTER, CEILING

SUPPLY AIR GRILLE OR REGISTER, CEILING

ER

SG

EG

EXISTING WORK TO BE REMOVED.

POINT OF CONNECTION NEW TO EXISTING

OR END OF DEMOLITION WORK

EXISTING WORK TO REMAIN.(E)

(R) REMOVE EXIST WORK

D

C

A

B

& SYMBOLS AND ABREVIATION

MECHANICAL MATERIAL INDICATIONS

CHONG, ST

INSTALLATION TENT

CAMP HOVEY

320257

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

M-2

MECHANICALMECHANICAL

MECHANICAL GENERAL NOTES

EQUIPMENT PAD SIZE, INSTALLATION LOCATIONS, AND ADDITIONAL ITEMS.

10. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS FOR NEW WORK SUCH AS EQUIPMENT & SERVICE CLEARANCE, COMMENCING ANY CONSTRUCTION OR RENOVATION.

9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITION AND DIMENSIONS PRIOR TO

8. ALL VALVES ON WET PIPE SYSTEM SHALL MEET NFPA 13 REQUIREMENT.

7. INSATLL SYSTEM TEST CONNECTION ON WET PIPE SYSTEM AND SHALL BE LOCATED AT THE MOST REMOTE BRANCH LINE.

6. SPRINKLERS WITH O-RINGS ARE NOT PERMITTED. PLUG TYPE TAMPER SWITCH SHALL NOT BE USED.

TO ALL RISER AND TRIM, SECTIONAL VALVES, INSPECTIORS TEST VALVES AND DRAINS.

5. PROVIDE LABEL TAG INDICATING "NORMALLY OPEN" OR "NORMALLY CLOSED" ON ALL VALVES INCLUDING AND NOT LIMITED

FLEXIBLE COUPLINGS, CLEARANCES, AND SEPARATION ASSEMBLES.

PIPING AGAINST DAMAGE WHERE SUBJECT TO EARTHQUAKES". INCLUDING, BUT NOT LIMITED TO, SWAY BRACINGS,

4. PROVIDE ALL SEISMIC PROTECTION MEASURES FOR THE FIRE PROTECTION SYSTEM IAW NFPA 13 FOR "PROTECTION OF

PIPES LESS THAN 50MM (2 INCHES) IN NOMINAL.

OF FLUID CARRIED AND DIRECTION OF FLOW. LABELS ARE NOT REQUIRED ON SPRINKLER SYSTEM BRANCH LINES AND

CONFORMING TO ASME/ANSI A13,1-1996 "SCHEME FOR IDENTIFICATION OF PIPING SYSTEMS", INDICATING THE TYPE

3. MARK ALL EXPOSED INTERIOR PIPING AT 8 METER(26 FT) INTERVALS, WITH PLASTIC WRAPAROUND TYPE PIPE LABLES

2. THE CLEARANCES AROUND PIPE PENETRATION AT FIRE RATED WALLS AND/OR FLOOR SHALL BE PROPERLY SEALED

WITH APPROVED FIRE STOPPING MATERIAL IAW SPECIFICATION 07 84 00.

11. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT OR REPAIR ALL DAMAGES TO EXISTING AREAS CAUSED

NO ADDITIONAL COST TO THE GOVERNMENT, INCLUDING, BUT NOT NECESSARILY LIMITED TO ITEMS SUCH AS WALLS, CEILLING, ROOF, PIPE, DUCT, EQUIPMENT AND ELECTRICAL ITEMS.

12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND REINSTALLATION OF ALL OBSTRUCTIONS AS NECESSARY

TO NECESSARY TO ALLOW FOR INSTALLATION AND REPLACEMENT OF MECHANICAL AND FIRE PROTECTION SYSTEM AT

19. PROVIDE ACCESS PANELS TO ALL CONCEALED VALVES, DAMPERS, AND EQUIPMENT. PROVIDE ACCESS DOORS

IN DUCTS AT ALL AUTOMATIC CONTROL DAMPERS, FIRE DAMPERS, FIRE/SMOKE DAMPERS, DUCT SMOKE DETECTOR, BACKDRAFT DAMPERS AND FOR ANY ITEM INDISE DUCTS REQUIRING SERVICING OR INSPECTION 12"X12" ACCESS

PANELS FOR TWO VALVES. COORDINATE THE LOCATION OF ACCESS PANEL TO INSURE THAT THE EQUIPMENT

CAN BE MAINTAINED ADEQUATELY. PROVIDE REMOTELY ACTUATED DAMPERS IN AREA WITH GYPBOARD OR

CONCEALED CEILINGS.

20. INSTALL CONDENSATE DRAINS AT A MINIMUM SLOPE OF 1 / 4INCH PER 1FOOT. INSULATE ALL SEWER PIPING

RECEIVING AIR CONDITIONING CONDENSATE DRAINS, OR ANY OTHER COLD LIQUID WHICH MAY CREATE

CONDENSATION, FROM SINK BODIES EXPOSED TO AIR BELOW THE FLOOR.

21. PROVIDE TURNING VANES IN ALL ELBOWS THAT CHANGE AIR DIRECTION MORE THAN 30 DEGREES OR

USE RADIUS ELBOWS. PROVIDE AIR SPLITTER DAMPERS AT ALL BRANCH TAKE-OFFS FROM THE MAIN DUCT.

PROVIDE SPIN-IN TYPE FITTINGS AT ALL ROUND DUCT TAKE-OFFS FROM SQUARE OR RECTANGULAR MAINS.

22. PIPING SYSTEM SHALL BE FLUSHED, PURGED & CLEANED PER SPECS REQUIREMENTS AND FLUSHED UNTIL

ALL WATER BEING FLUSHED IS CLEAR AS TAP WATER.

23. ALL CONDENSATE DRAINS FROM COOLING UNIT (AS NOTED ON THE DRAWINGS) SHALL BE PROVIDED WITH

SHUT-OFF VALVE WITHIN 1M OF THE UNIT.

24. DISPOSAL OF CONSTRUCTION DEBRIS, WASTE MATERIALS, MATERIALS RESULTING FROM DEMOLITION ACTIVITIES,

1. THE EQUIPMENT SHOWN ON THE PLAN ARE SUGGESTED LOCATIONS. FINAL LAUOUT SHALL BE VERIFIED AND

IN ACCORDANCE WITH APPLICABLE CODES, MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT LISTINGS.

THE CONTRACTOR SHALL COORDINATE SPRINKLER HEADS LOCATIONS WITH, LIGHTING FIXTURES, AND HVAC DEVICES.

ALL EQUIPMENT SHALL BE UL LISTED AND/OR FM APPROVED IN ACCORDANCE WITH NFPA 13, NFPA 20 AND THE PROJECT

SPECIFICATION.

BY THIS PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS AT HIS OWN COST.

13. CONNECT TO EXISTING SYSTEM SHALL BE DONE IN SUCH A MANNER AS NOT DAMAGE ANY EXISTING EQUIPMENT

DUCT WORK, PIPING ETC. DAMAGED DUE TO THE WORK PERFORMED UNDER THIS CONTRACT SHALL

BE REPAIRED OR REPLACED BY THIS CONTRACTOR AT HIS OWN COST.

14. CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION SHOP DRAWINGS FOR APPROVAL BY THE

CONTRACTING OFFICER.

AND THE LIKE SHALL BE DONE BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE GOVERNMENT.

15. FOR O & MA PROJECTS, KOREA, OCTOBER 1, 2003 DEPARTMENT OF THE ARMY FORM AS A PART OF THIS PROJECT.

THE DETAILS SHALL BE UTILIZED WHILE PERFORMING THE MECHANICAL SCOPE OF WORK.

16. SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACT FIELD CONDITIONS. SUCH DETAILS

SHALL BE PREPARED IN THE FIELD BY THE CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND

SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL.

17. ALL MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED AND BALANCED BY THE CONTRACTOR IN STRICT

ACCORDANCE WITH APPLICABLE SECTIONS OF DIVISION 22 & 23 - MECHANICAL, O & MA STANDARD TECHNICAL

SPECIFICATIONS FOR MISCELLANEOUS PROJECTS, KOREA. THE HVAC TESTING, ADJUSTING AND BALANCING (TAB)

REPORT SHALL BE SUBMITTED TO THE PROJECT COR FOR GOVERNMENT REVIEW AND APPROVAL.

18. ALL SUPPLY, RETURN AND EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED ACCORDING TO SMACNA STATIC

PRESSURE CALSS 500PA AND DUCTWORK SHALL MEET THE REQUIREMENTS OF SEAL CLASS C.

SCOPE OF WORK

BY A LICENSED OR CERTIFIED INSTALLER.

8. INSTALLATION OF THE HVAC SYSTEM SHALL BE IN COMPLIANCE WITH MANUFACTURER'S SPECIFICATION

7. ANY PIPES THAT PENETRATE FIRE RATED WALL (EXISTING/ NEW) SHALL BE SEALED PER SPEC.

CONDUITS AND ALL NECESSARY ACCESSORIES FOR H.V.A.C CONTROLS.

6. THE MECHANICAL/CONTROLS CONTRACTOR SHALL PROVIDE ALL THE WIRINGS, RELAYS, CONTROLLERS, PROVIDE REMOTELY ACTUATED DAMPERS IN AREAS WITH GYPBOARD OR CONCEALED CEILINGS.

5. PROVIDE VOLUME DAMPERS ON DUCTWORK BRANCH LINES WHETHER SHOWN ON THE DRAWINGS OR NOT.

UL LISTED.

DAMPER RATINGS SHALL BE COMPATIBLE WITH THE FIRE WALL OR FLOOR. FIRE DAMPERS SHALL BE

4. PROVIDE FIRE DAMPERS AT ALL DUCT PENETRATIONS THROUGH FIRE RATED WALLS AND FLOORS. FIRE

TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES.

3. PROVIDE DIFFUSERS AND GRILLE FRAMES COMPATIBLE WITH ARCHITECTURAL CEILING TYPES. REFER

THE CONTRACTING OFFICER.

2. THE CONTRACTOR SHALL SUBMIT MECHANICAL SYSTEM INSTALLATION SHOP DRAWINGS FOR APPROVAL BY

CLEARANCE, INSTALLATION LOCATIONS, AND ADDITIONAL ITEMS.

1. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS FOR NEW WORK SUCH AS EQUIPMENT & SERVICE

AND NOTE

GENERAL NOTES, SCOPE OF WORK

NOTE :

WORK CLASS "L" (CONSTRUCTION WORK)

CHONG, ST

INSTALLATION TENT

CAMP HOVEY

320257

ALL ASSOCIATED ACCESSORIES IN THE TEMPORARY TENT AS SHOWN ON DRAWINGS.

3. INSTALL NEW DISHWASHER, TABLE ROLLER, PRE-WASHING TABLE AND CLEAN DISH TABLE AND

AS SHOWN ON DRAWINGS.

2. CONNECT TO KITCHEN EQUIPMENT AND UTILITY LINE AND ALL ASSOCIATED ACCESSORIES FOR TEMPORARY TENT

1. RELOCATE EXISTING KITCHEN EQUIPMENT FROM DFAC TO TENT AS SHOWN ON DRAWINGS.

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

M-3

KITCHEN AREA FOOD SERVING AREA

QUEUING AREAQUEUING AREA

1 SINK HEATER

POWER SOAK UNIT

PRE-RINSE

FAUCET

208 3 9

NO QTY DESCRIPTION

EQUIPMENT

KWVOLTS PH AMPS

POWER

HP

ELECTRICAL

PLUG

CORD/

CONN

DIR

3/4"

3/4"

1/2"

3/4"

1/2"

PLUMBING

WATER

CW HW

WASTE

DIR IND

208 1 20

110 1 223

2.55208 1 12.3 1"2 HOT SERVING TABLE

GRIDDLE 208 31 24

ICE MACHINE 110 1 8.9 1/2" 3/4"1

TWO DECK CONVECTION OVEN 22208 32

TWIN 6 GALLON STEAM KETTLE 24208 3 1/2" 1/2"67 1-1/2"1

3"2 DOOR ROLL-THRU REFRIGERATOR 110 1 1/213.42

WORKTABLE3

40 GALLON BRAISING PAN 208 3 75 27

TRAY SLIDELOT

6 REFRIGERATED COLD PAN 110 1 1/52.3 3/4"

2 SNEEZEGUARD WITH LIGHTS 110 1 1.5

3 HEATED WELLS 2.55208 1 12.3

1 110 1DISPLAY REFRIGERATOR 3/4"

4 110 1COFFEE BUNN

2 110 1BREAD CASE

1 110 1RICE COOKER

1 MILK DISPENSER 120 1 1/52.7

1 110 1MICROWAVE

1 CONVEYOR TOASTER 208 1 20.4 4.2

BEVERAGE/CONDIMENT COUNTER2

2"

WARMER

3/4"

1/2" 3/4"

1/2"

1 RANGE FLATTOP 208 3

GENERAL REMARKS

EXISTING EQUIPMENT TO BE REUSEDCLASS E

LEASED EQUIPMENT

INSTALLED FROM CONSTRUCTION FUNDS

CONTRACTOR FURNISHED, CONTRACTOR

CLASS L

LEGEND:

CLASS A

SCALE : 1 / 100M57

CLASS

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

NOTE :

REPLACED BY THIS CONTRACTOR AT HIS OWN COST.

THE WORK PERFORMED UNDER. THIS CONTRACT SHALL BE REPAIRED OR

DAMAGE ANY EXISTING KITCHEN EQUIPMENT, PIPING ETC. DAMAGED DUE TO

3. CONNECT TO EXISTING SYSTEM SHALL BE DONE IN SUCH A MANNER AS NOT

EXISTING KITCHEN EQUIPMENTS.

DIMENSIONS AND PIPING SIZE PRIOR TO REMOVING AND REINSTALLING

2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING CONDITION,

KITCHEN EQUIPMENTS IN TENT FOR APPROVAL BY THE DFEC USER.

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION OF

FLOT DFEC TENT KITCHEN EQUIPMENT

FLOT DFAC TENT KITCHEN EQUIPMENT PLAN - 1

PLAN-1 AND FOOD SERVICE EQUIPMENT

FOOD SERVICE EQUIPMENT & UTILITY SCHEDULE -1

& UTILITY SCHEDULE-1. LEGEND & NOTE

CHONG, ST

INSTALLATION TENT

CAMP HOVEY

320257

HOOD W/EXHAUST FAN(IN-HOUSE)

HOOD W/EXHAUST FAN(IN-HOUSE)

(IN-HOUSE)

HOOD W/EXHAUST FAN

(IN-HOUSE)

HOOD W/EXHAUST FAN

(IN-HOUSE)

HOOD W/EXHAUST FAN

(IN-HOUSE)

FLOOR TROUGH

(IN-HOUSE)

FLOOR TROUGH

FULL PARTITION

DISH WASHING AREA

EXIT AREA

OPENING

RETURN TABLE

AREA

ENTRANCE

DINING AREA (300 SEATS)

QUEUING AREACASHIER COUNTER LOW PARTITION

(H: 800)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

REMOVED & REINSTALL EXISTING EQUIPMENT(FROM DFAC TO TENT)

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

MECHANICAL

M-4

SCALE : 1 / 100M58

FLOT DFEC TENT KITCHEN EQUIPMENT

KITCHEN AREA

FULL PARTITION

LOW PARTITION

(H: 800)

FULL PARTITION

PIPE CONNECTION SIZE

FLOOR SINK OR FLOOR DRAIN

FD, -2", 2" PC

ABBREVIATIONS:

PC PIPE CONNECTION SIZE

FD

FFD

FS

FLOOR DRAIN

FUNNEL FLOOR DRAIN

FLOOR SINK

SETTING HEIGHT

JUNCTION BOX OR STUBJ

LEGEND:

GRATE AND WIRE MESH BASKET INSERT

FLOOR SINK WITH SEDIMENT BUCKET, HALF

FUNNEL FLOOR DRAIN

FLOOR DRAIN

DIRECT WASTE

INDIRECT WASTE

HOT WATER

COLD WATER

LEVEL FLOOR SLAB

RECESSED, INSULATED SLAB

3/4"

1"

1"

140 DEG.F

SCALE : 1 / 50M71

FLOT DFAC TENT KITCHEN EQUIPMENT PLAN - 2

M71-

DISH WASING AREA PARTIAL PLAN

EXISTING EQUIPMENT TO BE REUSEDCLASS E

LEASED EQUIPMENT

INSTALLED FROM CONSTRUCTION FUNDS

CONTRACTOR FURNISHED, CONTRACTOR

CLASS L

LEGEND:

CLASS A

NOTE :

REPLACED BY THIS CONTRACTOR AT HIS OWN COST.

THE WORK PERFORMED UNDER. THIS CONTRACT SHALL BE REPAIRED OR

DAMAGE ANY EXISTING KITCHEN EQUIPMENT, PIPING ETC. DAMAGED DUE TO

3. CONNECT TO EXISTING SYSTEM SHALL BE DONE IN SUCH A MANNER AS NOT

EXISTING KITCHEN EQUIPMENTS.

DIMENSIONS AND PIPING SIZE PRIOR TO REMOVING AND REINSTALLING

2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING CONDITION,

KITCHEN EQUIPMENTS IN TENT FOR APPROVAL BY THE DFAC USER.

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION OF

NO QTY DESCRIPTION

EQUIPMENT

KWVOLTS PH AMPS

POWER

HP

ELECTRICAL

PLUG

CORD/

CONN

DIR

PLUMBING

WATER

CW HW

WASTE

DIR IND

208 3 131 2"

GENERAL REMARKS CLASS

49.555-1/4 3/4"

PRE-WASHING TABLE

CLEAN DISH TABLE

TABLE ROLLER SIZE: 2500 * 750 * 850

SIZE: 2000 * 750 * 850

SIZE: 1500 * 750 * 850

RACK COVEYOR TYPE 2-TNAK

104104C 104B 104A

104A

B104

C104

A

A

A

A

DISH WASHING AREA

DISH WASHING AREA

EXIT AREA

OPENING

RETURN TABLE

AREA

ENTRANCE

DINING AREA (300 SEATS)

QUEUING AREACASHIER COUNTER

FOOD SERVING AREA

HIGH PARTITION

(H: 2,000)

LOW PARTITION

(H: 800)

DISHWASHER

PLAN-2 AND FOOD SERVICE EQUIPMENT

FOOD SERVICE EQUIPMENT & UTILITY SCHEDULE -2

& UTILITY SCHEDULE-2, LEGEND & NOTE

CHONG, ST

INSTALLATION TENT

CAMP HOVEY

320257

DISHWASHER / ELEC. TYPE

HOOD W/EXHAUST FAN(IN-HOUSE)

320257-Installation tent, Cp Hovey_M1
320257-Installation tent, Cp Hovey_M2
320257-Installation tent, Cp Hovey_M3
320257-Installation tent, Cp Hovey_M4

File details come from the government source that posted it. Updated .