77525_ARCH_Drawing.pdf
PDF 8 MB Posted
- Solicitation number
- W90VN824R0043
About this file
This document is a set of architectural drawings and specifications related to a fire protection system repair project for Building S-533 at Camp Casey in Korea. The project involves replacing and repairing various interior and exterior building components, including doors, windows, walls, ceilings, flooring, and roofing. Key details include:
The solicitation is a Request for Proposal (RFP) issued only to existing Area I & II General Construction Multiple Award Indefinite Delivery Indefinite Quantity (MAIDIQ) contractors under Contract Numbers W91QVN-24-D-0001 through 0020, 0082, 0099, 0103 and 0107. The project is to repair the fire protection system in Building S-533 at Camp Casey, Korea. The drawings provide detailed specifications for the interior and exterior renovations, including types of materials, colors, and finishes to be used. Extensive details are given for the architectural, finish, and door/window requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 77525_CIVIL_DWGS.pdf | ||
| Solicitation W90VN824R0043.pdf | ||
| 77525_ELEC_Drawing.pdf | ||
| 77525_MECH_DWGS.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
A-1
GENERAL NOTES
1. FLOOR WORK
2. INTERIOR & EXTERIOR WALL WORK
2.1
2.2
2.3
1.1
1.2
1.3
REPAIR / MAINTENANCE (K) WORK
SCOPE OF WORK (ARCHITECTURAL WORK)
4.6
4.7
4.1
4.3
4.4
4.5
3.5
4.2
3.2
3.3
4. MISC. WORK
3.1
3. INTERIOR & EXTERIOR CEILING/ROOF WORK
ON FLOOR PLANS AND FINISH SCHEDULE.
WATER RESISTANT OR 'X' TYPE) CEILING INCLUDING CEILING SUSPENSION SYSTEM AS SHOWN
REPLACE DETERIORATED EXISTING CEILING WITH NEW GYPSUM WALL BOARD (GWB, NORMAL,
SETS AS SHOWN ON NEW FLOOR PLAN AND DOOR SCHEDULE.
REPLACE DETERIORATED EXISTING DOORS AND DOOR FRAMES WITH NEW INCLUDING HARDWARE
17.
DOCUMENTATION TO 8 CES/CEAN.
THE CONTRACTOR SHALL PROVIDE THE NEW SURVEY REPORT AND ASBESTOS REMOVAL
ACCORDANCE WITH THE KOREA ENVIRONMENTAL GOVERNING STANDARD (KEGS).
PRIOR TO ANY WORK TO ASSURE THAT APPROPRIATE ASBESTOS CONTROL IS IN
AREA WILL NEED TO BE RESURVEYED AND ASBESTOS MATERIALS SHOULD BE REMOVED
WORK IN THE AFFECTED AREA AND NOTIFY THE CONTRACTING OFFICER. THE WORK
ASBESTOS CONTAINING MATERIAL ARE DISCOVERED, THE CONTRACTOR SHALL CEASE
IS NOT PRESENT IN THE AREAS AFFECTED BY THIS WORK: HOWEVER, IF SUSPECTED
VERIFYING THE PRODUCT IS ASBESTOS FREE. TESTS HAVE INDICATED THAT ASBESTOS
WILL PROVIDE A CERTIFICATE OR MSDS, WRITTEN IN ENGLISH, FROM THE MANUFACTURER
PERCENT BY WEIGHT) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR
THE CONTRACTOR IS REQUIRED TO USE "ASBESTOS FREE" MATERIALS (LESS THAN 0.1
PROVIDE LEVELING CONCRETE FOR EXISTING CONCRETE SLAB IF NEEDED.
HIGH SPOTS, PAINTING, AND UNEVEN SURFACE SHALL HAVE BEEN CORRECTED FOR NEW FLOORING.
TRUE, LEVEL PLANE WITH ALL DEFECTS SUCH AS ROUGH OR SCALING CONCRETE, LOW SPOTS,
FLOOR PLAN & INTERIOR FINISH SCHEDULE. THE EXISTING CONCRETE FLOORING SHALL BE SMOOTH, REPLACE DETERIORATED EXISTING FLOOR TILE WITH NEW PVCT INCLUDING VCB AS SHOWN ON NEW
GENERAL NOTES & SCOPE OF WORK
NOT IN THIS CONTRACT.
ALL FURNITURE WHICH IS SHOWN ON FLOOR PLANS AND DETAIL DRAWINGS IS GFGI AND
MANUFACTURES INDICATED.
PURPOSES ONLY. AND NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE
COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR BIDDING IDENTIFICATION 1.
ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE (COR).
CAUSED BY THIS PROJECT AND SHALL REPAIR THE DAMAGES TO MATCH UP TO
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES MADE TO EXISTING AREAS
FOR APPROVAL.
CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITION AND SUBMITED TO COR
CONDITION. IN THAT CASE, SHOP DRAWINGS SHALL BE PREPARED AT THE SITE BY THE
SOME DETAILS SHOWN ON CONTRACT DRAWINGS MAY NOT COINCIDE WITH THE FIELD
8.
FOR APPROVAL.
CONTRACTOR SHALL SUBMIT MANUFACTURER'S INSTALLATION SHOP DRAWINGS TO COR
2.
3.
4.
5.
6.
7.
CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER
IF THERE ARE ANY CONFLICTS WITHIN THE CONTRACT DOCUMENT. THE GENERAL
AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.
THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION
OF THE LOAD BEARING WALLS TO PREVENT COLLAPSE OF THE STRUCTURE
APPROPRIATE TEMPORARY SUPPORTS SHALL BE CONSTRUCTED PRIOR TO DEMOLITION
9.
10.
11.
12.
13.
14.
15.
BE AS A PART OF THE CONTRACT DOCUMENT OF THIS PROJECT.
STANDARD DETAIL DRAWINGS FOR O&MA PROJECT, KOREA, DATED OCTOBER 1, 2003 SHALL
NUMBERS ARE FROM TM-5-807-7 AND FEDERAL STANDARD NO. 595b, COLORS.
COLOR OF MATERIALS & PAINTS SHALL BE SELECTED BY USING AGENCY AND COLOR
DETAILS AND GET APPROVAL FROM COR. BEFORE FABRICATION AND INSTALLATION.
CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL DOOR/WINDOW
SPECIFICATION 15181.
ITEMS REQUIRING MAINTENANCE/OPERATION IAW THE SECTION 3.1.14, OMA STD
PROVIDE ACCESS DOORS FOR ALL CONCEALED VALVES, VENTS, CONTROLS AND OTHER
16.
WITHOUT ADDITIONAL COST TO THE GOVERNMENT.
HEATING, EQUIPMENT, ETC), ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM
REQUIRED FOR THE INSTALLATION AND/OR REPLACEMENT OF MECHANICAL (PLUMBING,
OBSTRUCTED ITEMS, CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING WHERE
THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL/REINSTALLATION OF ANY
OFFICE, DPW. PER DIRECTION FROM COR
SALVAGE OR SERVICEABLE MATERIALS SHALL BE RETURNED TO SUPPLY OR STORAGE
FROM THE MANUFACTURE SHOWING THE PRODUCT IS LEAD FREE.
A CERTIFICATE OR MATERIAL SAFETY DATA SHEET (MSDS), WRITTEN IN ENGLISH,
SOLIDS) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR SHALL PROVIDE
COATINGS WITH LESS THAN 0.05 PERCENT LEAD BY WEIGHT OF THE NON-VOLATILE
THE CONTRACTOR IS REQUIRED TO USE "LEAD FREE" COATINGS (LIQUID PAINTS OR
WALL : 2.290 SM. DEG K/W
ROOF : 4.215 SM. DEG K/W
R-VALUE for INSULATION :
BRACKET WITH NEW AS SHOWN ON FLOOR PLANS AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING FIRE EXTINGUISHER CABINETS(FEC) AND FIRE EXTINGUISHER
PLANS, SECTIONS, PICTURES AND INTERIOR FINISH SCHEDULE.
NORMAL, WATER RESISTANT OR 'X' TYPE) INCLUDING METAL STUDS AS SHOWN ON FLOOR
REPLACE DETERIORATED EXISTING ALL GWB WALL BOARD WALLS WITH NEW GWB WALL (GWB,
FLOORING. PROVIDE LEVELING CONCRETE FOR EXISTING CONCRETE SLAB IF NEEDED.
PICTURES AND DETAILS DRAWINGS. UNEVEN SURFACE SHALL HAVE BEEN CORRECTED FOR NEW
OM EXST CONC SLAB, MORTAR BED AS SHOWN ON FLOOR PLAN, INTERIOR ELEVATION, SECTION, REPLACE DETERIORATED EXISTING PVCT WITH NEW FLOOR PORCELAIN TILES INCLUDING CHIPPING
REPLACE DETERIORATED EXISTING ACCESS DOORS ON CEILING AS REQUIRED AND AS THEY ARE.
ON DOOR/WINDOW SCHEDULE. (NATURAL COLOR, OAK)
REPLACE DETERIORATED EXISTING WOODEN HEAD, JAM & SILL FOR ALL WINDOWS WITH NEW AS SHOWN
INTERIOR FINISH SCHEDULE.
CEILING TILES INCLUDING METAL SUSPENSION SYSTEMS AS SHOWN ON FLOOR PLANS AND
REPLACE DETERIORATED EXISTING CEILING WITH NEW ACOUSTICAL CEILING TILES AND WOOD
2.4
ON FLOOR PLAN, INTERIOR ELEVATION, SECTIONS, PICTURES AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING WOODEN WALL RAILS AND CEILING MOLDING WITH NEW AS SHOWN
REPLACE DETERIORATED EXISTING WINDOW HORIZONTAL MINI BLIND WITH NEW, FIREPROOF TYPE.
WINDOWS INCLUDING GLASS AS SHOWN ON FLOOR PLANS, ELEVATIONS AND WINDOW SCHEDULE.
REPLACE DETERIORATED EXISTING WINDOW WITH NEW FIXED ALUMINUM THERMAL BREAKER TYPE
4.8
AS PER MANUFACTURE'S RECOMMENDATION & SPECIFICATION.
APPLY FLUID-APPLIED WATERPROOF COATING ON EXISTING METAL ROOFS AND BUILT-UP ROOF
TANK IN MECH ROOM AS SHOWN ON MECHANICAL DWG AND PICTURE.
REPLACE DETERIORATED EXISTING STL HAND RAIL AND STL LADDER WITH NEW FOR NEW STORAGE
4.9
SCHEDULE.
ACCESSARIES AS SHOWN ON FLOOR PLAN, DETAIL DRAWINGS, PICTURES AND INTERIOR FINISH
REPLACE DETERIORATED EXISTING CARPETS, WOODEN/SSM BASE BOARDS WITH NEW INCLUDING
MATERIAL WALL) AS SHOWN ON FLOOR PLAN, PICTURES, INTERIOR FINISH SCHEDULE AND DETAILS.
REPLACE DETERIORATED EXISTING WALL WITH NEW WOODEN PANELS AND SSMW (SOLID SURFACE
INTERIOR FINISH SCHEDULE, PICTURES AND SECTION.
PAINT ON ALL INTERIOR CEILING SURFACES AS SHOWN ON FLOOR PLAN, INTERIOR ELEVATION, 4.10
PLAN AND PICTURES.
CLEAN EXISTING QUARRY TILES, FLOOR TILES, BASE AND GCWT WALLS AS SHOWN ON FLOOR
4.11
(THE LOCATION SHALL BE COORDINATED WITH USING AGENCY).
REMOVE/REINSTALL EXISTING UNIT SIGNAGES AND LOGOS AS SHOWN ON PICTURES.
REMOVE/REINSTALL EXISTING ELECTRICAL CEILING MOUNT PROJECTORS. (SEE ELEC. DWG).
INTERIOR FINISH SCHEDULE, ELEVATIONS, PICTURES AND SECTIONS.
PAINT ON ALL INTERIOR WALL SURFACES AND PAINTED DOORS AS SHOWN ON FLOOR PLAN,
NEW FLOOR PORCELAIN TILES AS SHOWN ON FLOOR PLAN AND HARDWARE SCHEDUEL.
REPLACE DETERIORATED EXISTING ALL THRESHOLDS WITH NEW WHERE FACE TO CORRIDOR FOR
3.4
PICTURES.
PAINT ON METAL EAVES, FASCIA, RAIN GUTTER AND DOWNSPOUT AS SHOWN ON FLOOR PLAN,
4.12 CLEAN UP EXISTING RED BRICK EXTERIOR WALLS AS SHOWN ON FLOOR PLAN AND PICTURE.
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM
KWON, CH CAMP CASEY
77525
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
REMOVE EXISTING DOOR
LEGEND
& DOOR FRAME
SCALE: 1/100
ARCHITECTURAL
A-2
ROOM
MECH
ROOM
ELEC
REF
WALK-IN
FREEZER
WALK-IN
STORAGE
DRY
OFFICE
RECEIVING
DISH WASHING
SERVICE AREA
WAITRESS
BAR
SERVICE
LIQUOR STO COOLER BAR
SERVICE
KITCHEN
GAME ROOM
CASHIER
OFFICE-1OFFICE-2
ADMIN
OFFICE
DINING
STATION
WAITRESS
STORAGE-2
PARTITION
FOLDING
MULTI USE-1
BALLROOM/
MULTI USE-2
BALLROOM/
MULTI USE-3
BALLROOM/
STORAGE-1
PARTITION
FOLDING
STORAGE
AUDIO RACK
STORAGEATM
BOOTH
W.TOILET
M.TOILET
GALLERY
VEST
LOBBY
NCO/EM
LOBBY
OFFICERS
VEST
JAN
M. TOILET
W. TOILET
M. SHOWER
W. SHOWER
JANITOR
LOCKER/DIN
EMPLOYEE
DINING
DINING
DINING
STORAGE
KITCHEN
EXISTING/ REMOVAL FLOOR PLAN
58,522
,2
,3
,5
EXISTING / REMOVAL PLAN
RAIL ONLY
REMAIN FOLDING PARTITION
REMOVE EXISTING WALL
PORCELAIN TILES
CONC SLAB FOR NEW
CHIPPING EXISTING
PARTITION & STORAGE-2
REMOVE EXISTING FOLDING
WINDOW AND BLOCK UP
REMOVE EXISTING ROLL UP
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
A-3
ROOM
MECH
ROOM
ELEC
REF
WALK-IN
FREEZER
WALK-IN
STORAGE
DRY
RECEIVING
DISH WASHING
SERVICE AREA
WAITRESS
BAR
SERVICE
COOLER
STORAGE
KITCHEN
GAME ROOM
CASHIER
ADMIN
KITCHEN
MULTI USE-1
BALLROOM/
MULTI USE-2
BALLROOM/
MULTI USE-3
BALLROOM/
STORAGE-1
PARTITION
FOLDING
STORAGE
AUDIO RACK
ATM
BOOTH
CORRIDOR
VEST
LOBBY
NCO/EM
LOBBY
OFFICERS
VEST
JAN
M. TOILET
W. TOILET
M. SHOWER
W. SHOWER
JANITOR
LOCKER/DIN
EMPLOYEE
S/S
103 105
125 124 122
138137
130 148 146
KITCHEN
BAMA
BAR
BAR/DINING
LINEN ROOM
STORAGE
STORAGE
CHEF ROOM
ROOM
CLOSET
ROOM
RED WOOD
STORAGE
LIQUOR
ROOM
COMM
OFFICE-1
W.TOILET
M.TOILET
58,522
12,1924,06428,4484,0649,754
8,0434,1494,0646,0716,4012,0323,4113,5002,0075,0264,0641,8007,954
,3
,6
,5
,0
,6
5,0803,0482,0328,3827,3412,565
2,6272,453
10,770 3,048
16,256
SCALE: 1/100
D1 D2
D4D3
D5 W1
W1
,2
NEW FLOOR PLAN
LEGEND
DOOR FRAME
NEW DOOR &
WINDOW FRAME
NEW WINDOW &
150 MET STUD WALL
EXST WALL
D6
D7
D8
D9
D10
FEC
FEC
NEW FLOOR PLAN
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM
SCALE: 1/100
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
A-4
17,12029,15914,681
60,960
,1
,7
,6
,5
PROTECTED METAL ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
BUILT UP ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
PROTECTED METAL ROOF (TYP)
WATERPROOFING ON EXISTING
APPLY ACRYLIC FLUID-APPLIED
EXISTING ROOF PLAN
EXISTING ROOF PLAN
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-5
ARCHITECTURAL
SCALE: 1/25
CASHIER
ADMIN
JAN
OFFICE-1
M.TOILET
D9
D8
D10
GAME ROOM
,8
,0
,6
,0
1,880
2031,0162,845
ROOM 110, 111 & 112
ENLARGED PARTIAL FLOOR PLAN FOR OFFICE AREA
ENLARGED PARTIAL FLOOR PLAN-1
8,280
,5
A-8 1B
A-8 1D
ON 50THK MET STUD
PAINT ON 15THK GWB
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-6
ARCHITECTURAL
D5 W1
W1
1,050 600 1,300
BOOTH AUDIO RACK
SCALE: 1/25
PLAN FOR ROOM 123
ENLARGED PARTIAL FLOOR
STORAGE
2,275
,3
,6
D6
SCALE: 1/25
PLAN FOR ROOM 126
ENLARGED PARTIAL FLOOR
ROOM
CLOSET
D7
SCALE: 1/25
PLAN FOR ROOM 127
ENLARGED PARTIAL FLOOR
,6
1,560
ENLARGED PARTIAL FLOOR PLANS-2
A-8 1A
A-8 1A
A-8 1C
A-8 1E
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-7
ARCHITECTURAL
,2
OPEN OPEN
,2
,2
(TYP)
GWB W/150T MET STUD
PAINT ON 15THK
WD WALL RAIL (TYP)
PAINT ON EXST
(TYP)
WALL PANEL
PAINT ON EXST
WALL PANEL (TYP)
PAINT ON EXST
WD WALL RAIL
*MATCH TO EXST
W/PAINT (TYP)
WOOD WALL RAIL
ROOM
CLOSET
STORAGE
,0
,5
SCALE: 1/50
INTERIOR ELEVATIONS (CORRIDOR 108 )
BEHIND WINDOW
ROOM
SCALE: 1/50
SCALE: 1/50
INTERIOR ELEVATIONS (BALL ROOM 122 )
INTERIOR ELEVATIONS (RED WOOD RM 128 )
MARBLE WALL
CLEAN EXST
WD WALL PANEL (TYP)
CLEAN & PAINT ON EXST
WALL MOLDING (TYP)
CLEAN & PAINT ON EXST
CEILING MOLDINGL (TYP)
CLEAN & PAINT ON EXST
(TYP)
ACST CELING
WD WALL RAIL
*MATCH TO EXST
W/PAINT (TYP)
WOOD WALL RAIL
12THK GWB (TYP)
PAINT ON
,7
,1
(TYP)
WOOD FRAME & PANEL
PAINT ON EXST
NEW GWB (TYP)
PAINT ON 15THK(TYP)
GWB W/150T MET STUD
PAINT ON 15THK
WALL MOLDING (TYP)
CLEAN & PAINT ON EXST
DOOR (TYP)
CLEAN EXST GLASS
SEE DOOR SCHEDSEE DOOR SCHED
INTERIOR ELEVATIONS
,3
,1
A-7
,2
,2
SCALE: 1/50
DETAIL ELEVATION @ CORRIDOR
CEINLING MOLDING
NEW WOOD
,3
WD WALL RAIL (TYP)
PAINT ON EXST
(TYP)
GWB W/150T MET STUD
PAINT ON 15THK
* MATCH TO EXST PANEL
WALL PANEL (TYP)
(TYP)
SSM BASE BOARD
*MATCH TO EXST WALL PANLE
WALL PANEL (TYP)
*MATCH TO EXST WALL PANLE
WALL PANEL (TYP)
PAINT ON 15THK GWB (TYP)
(TYP)
WOOD BASE BOARD
SEE DOOR SCHED
SEE DOOR SCHED
(TYP)
SSM BASE BOARD
(TYP)
W/ MET STUD & SOUND INSUL.
SSM WALL PANEL
(TYP)
DOOR & DOOR FRAME
PAINT ON EXST ALL SEE DOOR SCHED
INSUL. (TYP)
W/MET STUD & SOUND
PAINT ON 15THK GWB
WALL RAIL (TYP)
VARNISH ON
(TYP)
WOOD WALL RAIL
PAINT ON GWB (TYP)
(TYP)
SSM BASE BOARD
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM
A-8
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
INTERIOR WALL SECTION
1A
STORAGE
ROOM
CLOSET
ROOM
RED WOOD
CARPET
20 THK OAK WOOD
PAINT ON 12T GWB
ON 12 THK PLYWOOD ON 150 MTL
STUD @400 OC(TYP) VCB
PVCT
,5
VCB
ACST CEILING ACST CEILING
1B
PVCT
100THK GLASS FIBER
INSULATION(30KG/m)
@ 400 O.C.(MAX)
ON 150 MET STUD
ON 15THK GWB
PAINT
OFFICE-1
ADMIN
VCB
,5
1C
VCB
ACST CEILING ACST CEILING
1D
PVCT
100THK GLASS FIBER
INSULATION(30KG/m)
@ 400 O.C.(MAX)
ON 150 MET STUD
ON 15THK GWB
PAINT
ADMIN
VCB
,5
PVCT
SCALE: 1/25
INTERIOR WALL SECTIONS
CASHIER
CARPET
PAINT ON 12T GWB
ON 18 THK PLYWOOD ON 150 MTL
STUD @400 OC(TYP)
VCB
PVCT
,5
W/MTL ANGLE FRAME
12 THK GWB
PAINT ON
,2
,2
,5
MULTI USE-3
BALLROOM/
12 THK WOOD WALL PANEL
,3
BOOTH AUDIO RACK
CARPET
,5
MULTI USE-3
BALLROOM/
CORRIDOR
1E
,2
,2
(TYP)
13T SSM ON 12T PLYWOOD
CONC SLAB (TYP)
ON CHIPPING ON EXST
ON CEMENT MORTAR BED
FCT ON CEMENT BOND COAT
ON 12 THK PLYWOOD
13 THK SSM WALL PANEL
20 THK OAK WALL RAIL
ON EXST MET STUD
ON 12 THK PLYWOOD
ON EXST MET STUD
MET STUD NOTES
FOR NEW INTERIOR FINISH, IF NEEDED.
1. REINFORCE EXST METAL STUD & FURRING CHANNEL
PAINT ON EXST WD WALL PANEL
PAIN ON EXST WD WALL RAIL
CEINLING MOLDING
PAINT ON EXST WOOD
PAINT ON 15THK NEW GWB
@WD & PANEL
EXST CEILING SYSTEM
CLEAN & PAINT
OAK (NATURAL FINISH)
WD HEAD, JAMB, SILL
@400 O.C (TYP)
ON 150 MET STUD
PAINT ON 15THK GWB
@400 O.C (TYP)
ON 150 MET STUD
20 THK OAK WALL RAIL
WALL PANEL (MATCH TO EXST ONE)
100THK GLASS FIBER
INSULATION(30KG/m)
,7
,1
,2
,2
PAINT ON 15THK GWB
PAINT ON 15THK GWB
20 THK OAK WALL RAIL
ON 150 MET STUD
PAINT ON 15T GWB
*MATCH TO EXST MOLDING
NEW WOOD MOLDING
@400 O.C.
ON 150 MET STUD
PAINT ON 15THK GWB
W/MTL ANGLE FRAME
12 THK GWB
PAINT ON
PAINT ON 15THK GWB
PAINT ON 15T GWB
W/MTL ANGLE FRAME
12 THK GWB
PAINT ON
GWG (TYP)
PAINT ON 12THK
13T SSM BASE BOARD
13THK SSM BASE BOARD
WOOD CEILING
PERFORATED
WOOD CEILING
PERFORATED
PVCT
& MET STUD
W/MET ANGLE FRAME
12 THK GWB
PAINT ON
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM
A-9
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
1_RM 102, LOBBY
SCALE: N/A
@400 O.C (TYP)
ON 150 MET STUD
FCT
BASE BOARD
13T SSM
2_RM 115, LOBBY
12 THK NEW GWB
PAINT ON
GLASS DOOR
CLEAN EXST
FCT
BASE BOARD
13T SSM
@400 O.C (TYP)
ON 150 MET STUD
PANEL
SSM WALL
3_RM 108, CORRIDOR-1 4_RM 108, CORRIDOR-2
5_RM 108, CORRIDOR-3
W/MET STUD
12 THK GWB
PAINT ON
13T SSM WALL PANEL
OAK WALL RAIL
PAINT ON 15THK GWB
12 THK GWB
PAINT ON
PAINT ON 15THK GWB
OAK WALL RAIL
13T SSM WALL PANEL
W/PAINT
LETTERS & SIGNAGE
REMOVE/REINSTALL EXST
W/MET STUD
PAINT ON 15THK GWB
W/MET STUD
PAINT ON 12THK GWB
GWB(TYP)
PAINT ON 12THK
FLOOR FINISH
CLEAN EXST
GWB(TYP)
PAINT ON 12THK
DROP CEILING
PAINT ON EXST
WALL PANEL (TYP)
GWB WALL & WOOD
PAINT ON EXST
WD PANEL AND FRAME
PAINT ON EXST
CEILING PANEL
CLEAN EXST
FCT BASE BOARD
13T SSM
GWB W/MET STUD
PAINT ON 15THK
BASE BOARD
13T SSM
RAIL & WD WALL PANEL (TYP)
MOLDING, WALL COLUMNS, WALL
PAINT ON EXST CEILING CARPET
CARPET
WOOD CEILING
W/MET STUD
PAINT ON 15THK GWB
W/MET STUD
PAINT ON 15THK GWB
& STOAGE
REMOVE FOLDING WALL
FOLDING WALL RAIL
REMAIN EXST
WOODEN DOOR (TYP)
VARNISH ON EXST
W/MET STUD
PAINT ON 15THK GWB
CARPET
BASE BOARD
13T SSM
WOOD CEILING
REMOVE DROP CEILING
& WALL MOLDING (TYP)
RAIL, WD WALL PANE
PAINT ON EXST WALL
W/MET STUD
PAINT ON 15THK GWB
(TYP)
EXST GRIL
CLEAN
W/WOOD CEILING
DROP CEILING
REMOVE EXST
MOLDING AND COLUMN
PAINT ON EXST WALL
GWB DROP CLG (TYP)
PAINT ON 12THK
(TYP)
GWB DROP CLG
PAINT ON 12THK
(SEE DWG)
(SEE DWG)
(SEE DWG)
(SEE DWG)GWB DROP CLG (TYP)
PAINT ON 12THK
(SEE DWG)
7_BALL ROOM 1,2,3-1 8_BALL ROOM 1,2,3-2
9_BALL ROOM 1,2,3-3 10_BALL ROOM 1,2,3-4 11_BALL ROOM 1,2,3-5
WOOD CEILING
(SEE DWG)
(SEE DWG)
GWB DROP CLG (TYP)
PAINT ON 12THK
W/MET STUD
PAINT ON 15THK GWB
MOLDING (TYP)
PAINT ON EXST WALL
6_BAMA/BAR/DINING ROOM
W/PAINT
LETTERS & SIGNAGE
REMOVE/REINSTALL EXST
BUILDING PICTURES - 1
BUILDING PICTURES - 1
(SEE ELEC DWG)
MOUNT (TYP)
ELECTRICAL PROJECTOR
REMOVE/REINSTALL
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM
(SEE DWG)
GWB DROP CLG (TYP)
PAINT ON 12THK
WOODEN DOOR (TYP)
VARNISH ON EXST
BASE BORD
OAK WOOD
WALL PANEL (TYP)
PAINT ON EXST
ON 150 MET STUD
PAINT ON 15T GWB
CARPET
CARPET
WALL PANEL (TYP)
PAINT ON EXST
ON 150 MET STUD
PAINT ON 15T GWB
GWB DROP CLG (TYP)
PAINT ON 12THK
(SEE DWG)
FOLDING CURTAIN W/RAIL
REMOV/REINSTALL
13_RM 128, RED WOOD RM-212_RM 128, RED WOOD RM-1
GWB DROP CLG (TYP)
PAINT ON 12THK
GWB CLG (TYP)
PAINT ON 12THK
& GCWT (TYP)
CLEAN QUARRY TILE
14_RM 149, KITCHEN
PAINT COLOR NOTE
A-10
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
SCALE: N/A
BUILDING PICTURES - 2
BUILDING PICTURES - 2
15_RM 138, MECH ROOM
NEW STORAGE TANK
PAINT ON NEW STL HAND RAIL FOR
NEW STORAGE TANK
PAINT ON NEW STL LADDER FOR
17_EXTERIOR PIC
ON EXST BUILT-UP ROOF (TYP)
APPLY FLUID-APPLIED WATERPROOF
ON EXST MET ROOF (TYP)
APPLY FLUID-APPLIED WATERPROOF
16_RM 113, CASHIER ROOM
AND BLOCK UP OPENING
REMOVE EXST ROLL UP WINDOW
GWB CLG (TYP)
PAINT ON 12THK
15THK GWB
PAINT ON
WOODEN WALL RAIL (TYP)
PAINT ON EXST
(TYP)
OAK WOOD BASE BORD
AND EAVES (TYP)
PAINT ON EXST MET FASCIA
AND DOWNSPOUT (TYP)
PAINT ON EXST RAIN GUTTER
WITH USING AGENCY THROUGH COR.
1. ALL INTERIOR PAINT COLOR AND FACTORY COLOR/PATTERN SHALL BE COORDINATED
RED BRICK EXTERIOR WALL (TYP)
CLEAN UP EXISTING
18_EXTERIOR PIC
AND EAVES (TYP)
PAINT ON EXST MET FASCIA
(TYP)
PAINT ON EXST RAIN GUTTER
(TYP)
PAINT ON EXST DOWNSPOUT
(TYP)
RED BRICK EXTERIOR WALL
CLEAN UP EXISTING
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM
W/ 9 DIA EXP BOLT
@ 600 OC (MAX)
ON 50 THK TREATED WOOD
13T SOLID SURFACE MATER
SCHEDULE
FINISH PER
13 THK SSM ON 12 THK
PLYWOOD
SCHEDULE
FINISH PER
A-11
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
SCALE
HANGER WIRE
REINFORCEMENT
100x100x1.6THK
CHANNEL
PAINT ON
CORNER
PAINT ON
CHANNEL @400 O.C.
BENT CHANNEL(TYP)
(SEE ELEC DWG)
LIGHTING FIXTURE
ROOF LINER
(TYP)
ACST CLG
AL MOLDING
1/10
611 303
-100x50x20x2.3 METAL
CHANNEL @ 600 OC
@ 1200 O.C
12THK GWB
ON 90 MET
@ 400 O.C.
12THK GWB
ON 90 MET
o r
T O
F
L ,7 o r
,0
15 THK GWB
PVCT
VCB (TYP)
R=5
20 THK OAK WOOD
PAINT ON
NOTE
o r
*±400 or ±500 : MATCH TO ACTUAL FIELD CONDITION
ROOM
RED WOOD
BALLROOM/
DROP CEILING DETAIL
RED WOOD & BALLROOM/MULTI USE ROOMS
MULTI USE-1,2&3
PLAN SECTION "A-A"ELEVATION
EXTINGUISHER CABINET
METAL DOOR PULL
(OUTSIDE TRIM DIM)
O
U T S
ID
E
R
IM
D
IM
METAL TRIM
GLASS
METAL FIRE
(ALL AROUND)
WOOD SHIM
METAL DOOR
PULL
(OUTSIDE TRIM DIM)
METAL DOOR
PULL
(ALL AROUND)
WOOD SHIM
A
A
SCREW (3-PER SIDE)
2A 2B 2C
(INSIDE BOX DIM)
(ROUGH OPENING)
30030 30
SCALE: N/A
FIRE EXTINGUISHER CABINET DETAILS
SCHEDULE
FINISH PER
DETAILS - 1
HANGING ROD
4 DIA HOLE (TYP)
CLOTHES
25 DIA SST PIPE
-25x25x2
2.5 THK SST
BRACKET
R
5 50
0 50
@ 900 OC
SCALE: 1/5
SHELF & ROD DETAILS (CLOSET)
4C
PLASTIC LAMINATE (PL-1)
L
O O
R
HANGING ROD
SST BRACKET
CLOTHES
2.5 THK
25 DIA SST PIPE
-25x25x2 SST BRACKET
POSTFORM
9 DIA TOGGLE BOLTS
22x200 WOOD
1.6 THK SST SOCKET
CLOTHES HANGING ROD
25 DIA SST PIPE
9 DIA TOGGLE BOLTS
22x200 WOOD
PAINT GWB
PAINT GWB
BOTH SIDES-SHELF & SIDE PANEL
ON 18 THK PLYWD
PLASTIC LAMINATE (PL-1)
ON 18 THK PLYWD
@ 300 O.C
SEE DETAIL 2C
@ 900 OC
100350
4A 4B
@ 900 OC
SCALE: N/A
BASE DETAILS
3A
3B
3C
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM
GYPSUM BOARD CEILING DETAILS
SCALE : 1/2
EXPOSED GRID ACOUSTICAL CEILING DETAILS
SCALE :
1/2
MAIN TEE &
ISOMETRICAT LIGHTING FURRINGAT LIGHTING FIXTUREAT MAIN TEEAT WALL
FACE OF WALL
ACOUSTICAL TILE CEILING
24x24 METAL MOULDING
W/ 5 DIA TOGGLE BOLTS OR
SCREW @ 400 OC
31x610 L CROSS TEE
@ 610 OC
@ 610 OC
38 MAIN TEE
31x610 L
CROSS TEE @ 610 OC
W/ HOLD DOWN CLIP
ACOUSTICAL TILE CEILING
38MM MAIN TEE
@ 610 OC
31x610 L
CROSS TEE
@ 610 OC
LIGHTING
FIXTURE
38 MAIN TEE
@ 610 OC
31x610 L
CROSS TEE
@ 610 OC
LIGHTING FIXTURE
ACOUSTICAL
TILE CEILING
1G
HOLD
ADDITIONAL HANGER WIRE
FOR LIGHTING FIXTURE
WHERE REQUIRED
(TYP)
MOULDING
610 L CROSS
TEE
MAIN TEE
AT LIGHTING
FIXTURE 610
CROSS TEE
1A
1B
1E 1D
1C
REQUIRED PER PANEL
Q'TY OF HOLD DOWN CLIPS NOTE:
a) FOR 610x610 PANEL 1A 1B 1D 1E 1F
1G
2F AT WALL
38 RUNNER
CHANNEL
@ 1200 OC
CASING TRIM
OR CONC NAIL
BOLTS OR EXP BOLTS
1.5 THK 40x40 METAL
CONT W/ 6 TOGGLE
GYPSUM BOARD
WIRE HANGER
@ 1200x900 OC
WIRE MESH SCREEN
ABOVE FIXTURE
BRACKET
TROFFER SUSPENSION
FRAMING
38 CHANNEL
SUPPLEMENTARY
TROFFER
JOINT COMPOUND
METAL CONTROL
JOINT TRIM TREATMENT
TAPE JOINT
TIE WIRE
38 RUNNER
CHANNEL
@ 1200 OC
AT CONTROL JOINT2D2C AT FURRING
22 FURRING
CHANNELCHANNEL
22 FURRING
@ 1200 OC
CHANNEL
38MM RUNNER
GYPSUM BOARD
WIRE HANGER
@ 1200x900 OC
AT FURRING AT LIGHTING FIXTURE2E2B
WIRE HANGER
@ 1200x900 OC
2A
GYPSUM BOARD
AT WALL
50 MAX
FACE OF WALL
(CMU OR GWB WALL)
EXPOSED OR
SEMI-EXPOSED OR
CONCEALED GRID
1C AT CROSS TEE
METAL
DOWN CLIP
CROSS TEE
@ 1200 OC
ISOMETRIC
WIRE BRACING
@ 3600 OC (TYP)
12 GA DASHED LINE FOR
4-WAY SPLAYED
@ 3658 OC (TYP)
12 GA DASHED LINE
FOR 4-WAY SPLAYED
WIRE BRACING
WIRE BRACING
@ 3658 OC (TYP)
4-WAY SPLAYED
FOR FIRST 4-WAY SPLAYED WIRE BRACING
1829 MAX
FOR FIRST HANGER
150 MAX
FROM THE WALL
FOR FIRST FROM THE WALL
10 GA WIRE HANGER
@ 1219 OC (TYP)
FROM THE WALL
FOR 4-WAY SPLAYED WIRE BRACING (TYP)
FROM THE WALL
FOR FIRST 4-WAY SPLAYED WIRE BRACING
1800 MAX
WIRE HANGER
DASHED LINE FOR
4-WAY SPLAYED
WIRE BRACING
@ 3600 OC (TYP)
FOR 4-WAY SPLAYED WIRE BRACING (TYP)
M A
X
° M
A X
°M
A X
° M
A X
@ 1200x900 OC
FROM THE WALL
150 MAX
FOR FIRST HANGER
2. IF THE ROOM IS SMALL SPACE,
WIRE BRACING IS NEEDED 1 PER ROOM.
CENTER OF SMALL ROOM.
THE LOCATION SHALL BE PROVIDED
NOTES ;
INTERVAL BETWEEN CEILINGS CONTROL JOINTS
WHERE PERIMETER BREAK DOES NOT EXIST
EXPANSION AND CONSTRUCTION JOINTS
WHERE CEILING FRAMING OR FURRING
2EXCEEDING 230m .
SHALL BE INSTALLED IN CEILINGS
CONTROL JOINT SHALL BE PROVIDED
SHALL NOT EXCEED 9m IN CASES
WHERE PERIMETER BREAK EXIST, AND 12m
AROUND CEILING IN EITHER DIRECTION.
(MAX : 3600 x 3600 ) SPLAYED
10 GA
10 GA
A-12
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
75 W x 6 THK
CAM LATCH
STL PLATE FRAME
ACCESS PANEL
(LIGHT WEIGHT METAL)
14 GA STL
WIRE HANGER
38 RUNNER CHANNEL
@ 1200 OC
FRAME
SCALE : NOT TO SCALE
CONTINUOUS
16 GA STEEL
6 DIA BOLT & NUT
PIANO HINGE
@ EACH CORNER
CEILING ACCESS DOOR DETAIL
(FINISH MATCH TO CEILING)
-FINISH MATCH TO CEILING
12 THK GWB ON
65 METAL STUD
@ 400 OC
GYPSUM BOARD CEILING DETAILS
SCALE : 1/2
PAINT
* DEPEND ON SITE CONDITION
1.
DETAILS - 2
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
1.
MANUFACTURERS STANDARD MUST APPROACH.
COLOR IS NOT REQUIRED. THE SELECTIONS SERVE ONLY TO INDICATE THE COLOR WHICH THE
INTENDED TO LIMIT SELECTIONS OF PRODUCTS. AN EXACT MATCH OF THE MANUFACTURERS
MANUFACTURERS' COLORS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY AND ARE NOT 2.
3.
ROOM NAMESROOM NOS
FLOOR BASE WALLS CEILING
REMARKS
FINISH COLOR FINISH COLOR FINISH COLOR FINISH COLOR HEIGHT
SURFACE
ROOFING
FLASHING
FASCIA
SOFFIT
DOOR & FRAME
MATERIAL
STEEL
COLOR
CHOCOLATE
COLOR NO.
20095
CHOCOLATE
CHOCOLATE
CHOCOLATE
CHOCOLATE
20095
20095
20095
20095
REMARKS
WALL EIFS
WALL CMU
BEAM/COL CONC
CONC
SAND-STONE
SAND-STONE
SAND-STONE
SAND-STONE
23617
23617
23617
23617
PROTECTED METAL
EXTERIOR COLOR SCHEDULE-1
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
MAT'L
EXST
MAT'L
NEW
MAT'L
EXST
MAT'L
NEW
MAT'L
EXST
MAT'L
NEW
MAT'L
NEW
MAT'L
EXST
SHALL BE WATERPROOF TYPE GWB.GWB FOR TOILETS, AND OTHER WET AREAS 4.
GWB
PAINT PT-2GWB
FINISH SCHEDULE NOTES
STAIR WALLS
PROTECTED METAL
PROTECTED METAL
PROTECTED METAL
VCT GWB GWB
VEST-1
ATM
VEST-2
STORAGE
BAMA
STORAGE
- - - - GCWT-1FCT GCWT GWB GWB* PAINT PT-2 GWB* : WATERPROOF TYPE
GWB GWB* PAINT PT-2 GWB* : WATERPROOF TYPE
GWBPAINT PT-1VCT GWB GWBVCB
ACSTPAINT PT-1GWB ACST F.F. ACST-1-/- VCB
GWBPAINT PT-1VCT GWB GWBVCB
VCT
F.F. ACST 2500PAINT PT-1GWBVCT VCB F.F. VCB-1 GWB ACST F.F. ACST-1PVCT PVCT-1 VCB
F.F. ACSTPAINT PT-1GWBVCT VCB F.F. VCB-1 GWB ACST F.F. ACST-1PVCT PVCT-1 VCB
F.F. ACSTPAINT PT-1GWBVCT VCB F.F. VCB-1 GWB ACST F.F. ACST-1PVCT PVCT-1 VCB
PAINT PT-1VCT F.F. VCB-1 ACST F.F. ACST-1VCB
GWBVCB
PAINTVCT
CFT
ACSTCFT CWT GWB
F.F. PT-1SSM F.F. SSM-1CPT-1
ACST 2500PAINT PT-1GWBGWB ACST F.F. ACST-1
F.F. GWBGWB
ACST
QT - QTB
GCWT
F.F.
A-13
ARCHITECTURAL
& FINISH SCHEDULE NOTES
INTERIOR, EXTERIOR FINISH SCHEDULE
F.F.
- - - - - - -BRICK/WD -* -* : MATCH TO EXST CEILING HGT
OFFICERS LOBBY FCT FCT-1 WD
LINEN ROOM
W.TOILET
M.TOILET
CORRIDOR
JAN
OFFICE-1
CASHIER
ADMIN
GAME ROOM
NCO/EM LOBBY
BAR/DINGING
BAR
KITCHEN
KITCHEN
BALL RM/MULTI USE-3
BALL RM/MULTI USE-2
BOOTH AUDIO RACK
BALL RM/MULTI USE-1
CLOSET ROOM
RED WOOD ROOM
AREA
WAITERESS SERVICE
SERVICE BAR
DISH WASHING
CONC GWB GWB* PAINT PT-2
ACST
CONCCONC CMU-
RECEIVING
CHEF ROOM
DRY STORAGE
WALK-IN FREEZER
WALK-IN FREEZER
ELEC ROOM
-* -* : MATCH TO EXST CEILING HGTPAINT PT-2
- - - - - PAINT PT-2 -* -* : MATCH TO EXST CEILING HGT
CPT/VCT - - - - - -*
GWBVCT GWB GWBF.F. F.F.FCT FCT-1 WD -* -* : MATCH TO EXST CEILING HGTPAINT PT-2
SSM WALL
GWB/
SSM
SSM
SSM-1
SSM-1
- - - PAINT PT-2 -*
GWBCFT CWT GWB- - - PAINT PT-2 -*
WD -
WD PANEL
GWB/
GWB GWB PAINT -*- - WD -CLEAN
CLEAN
CLEAN
CLEAN
PAINT
PAINT
EXST
MATCH TO
EXST
MATCH TO
WD PANEL
GWB/
PAINT
EXST
MATCH TO
EXST
MATCH TO
PAINTVCT GWB GWB PAINT- - WD -CLEAN PAINT
EXST
MATCH TO
WD PANEL
GWB/
EXST
MATCH TO
GWB GWB PAINT -*
VCT - -CLEAN - - - - PAINT PT-1 GWB GWB PAINT PT-2 -*
COMM ROOM - - - - - - PAINT PT-2 -*
-* : MATCH TO EXST CEILING HGT
-* : MATCH TO EXST CEILING HGT
- - - -FCT GWB GWB* PAINT PT-2 GWB* : WATERPROOF TYPE
- - - -FCT GWB GWB* PAINT PT-2 GWB* : WATERPROOF TYPE
GCWT
GCWT
-* : MATCH TO EXST CEILING HGT
-* : MATCH TO EXST CEILING HGT
F.F. F.F.FCT FCT-1 WD SSM SSM-1
WALLPANEL
GWB
SSM WALL
GWB/
WOOD
ACRYLIC
CLEAN
PAINT
PT-2
- - - -* -* : MATCH TO EXST CEILING HGT
CLEAN
CLEAN
CLEAN
CLEAN
CLEAN
CLEAN
ACST
GWB/
-* -* : MATCH TO EXST CEILING HGT- - -
PAINT PT-2GWBQT - QTB- - - - - -BRICK/WD -* -* : MATCH TO EXST CEILING HGT
GWB
GWB
-* : MATCH TO EXST CEILING HGT
-* : MATCH TO EXST CEILING HGT
-* : MATCH TO EXST CEILING HGT
-* : MATCH TO EXST CEILING HGT
-* : MATCH TO EXST CEILING HGT
-* : MATCH TO EXST CEILING HGT
PT-2
PT-2
PT-2
CARPET CARPET SSM
WD PANEL
GWB/
GWB/
ACST
GWB/
WD CEILING
GWB/
F.F.
PAINT/
WC-1
PT-2
F.F. SSM F.F. SSM-1PVCT-1CARPET SSM
F.F. PT-1SSM F.F. SSM-1CPT-1CARPET CARPET SSM
WD PANEL
GWB/
GWB/
ACST
GWB/
WD CEILING
GWB/
F.F.
PAINT/
WC-1
PT-2
F.F. PT-1SSM F.F. SSM-1CPT-1CARPET CARPET SSM
WD PANEL
GWB/
GWB/
ACST
GWB/
WD CEILING
GWB/
F.F.
PAINT/
WC-1
PT-2
4000/
4000/
4000/
F.F. GWB* PAINT PT-1CARPET
GWB 2500GWB GWB*F.F. GWB* PAINT PT-1 PAINT PT-2 GWB* : FIRE RETARDANT TYPECARPET
2500GWB PAINT PT-2PVCT-1
F.F. PVCT-1 WB
WB
WB
WB
WB-1
WB-1
F.F. PT-1CPT-1CARPET CARPET
WD PANEL
GWB/
WB WB F.F. WB-1 GWB GWB PAINT PT-2
±3100
±2700/
QT - - QTBCLEAN CLEAN - -
-* -* : MATCH TO EXST CEILING HGT
- - GWB GWB PAINT PT-2GWBQT - - QTBCLEAN CLEAN - -* -* : MATCH TO EXST CEILING HGTPAINT PT-1
- - GWB* PAINT PT-2 GWB* : WATERPROOF TYPEGCWTQT - - QTBCLEAN CLEAN - - -* -* : MATCH TO EXST CEILING HGT
GWB* PAINT PT-2 GWB* : WATERPROOF TYPE-* -* : MATCH TO EXST CEILING HGTCLEAN
CLEAN --GCWT-CLEAN-QTB-CLEAN-QT
- - CMU GWBQT - - QTBCLEAN CLEAN - ACST -* -* : MATCH TO EXST CEILING HGTPAINT F.F. ACST-1
- CLEAN - VCB PAINT
PAINT
PAINT
PAINT
PAINT
PT-1 -* GWB* : FIRE RETARDANT TYPE
QT - - ---
WITH THE CAMP CASEY EXTERIOR COLOR SCHEME AS APPROVED BY THE COR.
SELECTION OF EXTERIOR PAINT AND FACTORY APPLIED COLORS SHALL BE IN ACCORDANCE
QTB MET - - - MET -
- - -QT - - ---QTB MET - - - MET -
INTERIOR FINISH SCHEDULE-1
PAINT
PAINT
EXST
MATCH TO
EXST
MATCH TO
WD PANEL*
GWB/ WD PANEL* : NEW WALL ONLY
BE APPROVED BY USING AGENCY.
SELECTION OF INTERIOR PAINT AND FACTORY APPLIED COLORS (CARPET, TILES & ETC) SHALL
CLEAN
CLEAN
CLEAN
CLEAN
CLEAN
CLEAN
VAR
CLEAN
CLEAN
SSM WALL
GWB/
F.F.
PAINT/
F.F.
PAINT/
F.F.
PAINT/
SSMW-1
PT-1/
SSMW-1
PT-1/
SSMW-1
PT-1/
PT-1
CMU -- - -
PVCT
PVCT
PVCT
GWB/WC -/-
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM
A-14
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
BASE MATERIAL/COLOR
M A T E R I A L & C O L O R S C H E D U L E
FLOOR MATERIAL/COLOR
PVCT-1
OR APPROVED EQUAL
457.2MMx457.2MM, 3MM THK
KCC SENSE TILE, CERAMIC, TN2412C
PVC TILE
FCT-1
CPT-1
KOLON
SEASON, RS-06
CARPET
CEILING MATERIAL/COLOR
VCB-1
PT-2
OR APPROVED EQUAL
DARK BROWN, 100 HGT, 3THK
LG HAUSYS
VINYL COVE BASE
WB-1
WALL MATERIAL/COLOR
: MOLD & MILDEW RESISTANT, STAIN PROOF
ANTIQUE WHITE
OR APPROVED EQUAL
ARDEX FG 4
* EPOXY GROUT COLOR FOR GCWT AND FT
WP-1
ACST-1
MISC MATERIAL/COLOR
WR-1
OR APPROVED EQUAL
OAK, NATURAL FACTORY FINISH
WOOD WALLRAIL
ACOUSTICAL TILE
ALUMINUM
ACOUSTICAL WALL PANEL
CEILING
COLOR
CONCRETE MASONRY UNIT
CONCRETE
COMMUNICATION
CARPET
CERAMIC WALL TILE
EXTERIOR INSULATION &
FINISH SYSTEM
ELECTRICAL
EXISTING
FINISH
GYPSUM WALL BOARD
HEIGHT
MEN
MATERIAL
MECHANICAL
METAL ROOF LINER
PAINT
REPAIR BY REPLACING
SKIM COAT PLASTER
VARIOUS
VINYL COVE BASE
VINYL COMPOSITION TILE
VINYL SHEET FLOORING
WOMEN
WOOD BASE
WOOD
ACST
AL
AWP
CLG
CLR
CMU
CONC
COMM
CPT
CWT
EIFS
ELEC
EXST
FCT
FNSH
GWB
HGT
M
MATL
MECH
MRL
RBR
SCP
VAR
VCB
VCT
VSF
W
WB WD
A B B R E V I A T I O N
PT
ARCHITECTURAL
MATERIAL & COLOR SCHEDULE
ROOM NAMESROOM NOS
FLOOR BASE WALLS CEILING
REMARKS
FINISH COLOR FINISH COLOR FINISH COLOR FINISH COLOR HEIGHT
MAT'L
EXST
MAT'L
NEW
MAT'L
EXST
MAT'L
NEW
MAT'L
EXST
MAT'L
NEW
MAT'L
NEW
MAT'L
EXST
ACSTPAINT PT-1VCT GWB ACST F.F. ACST-1VCB
GWBPAINT PT-1 GWB*QTB
GWBPAINT PT-1QTB
GWB* : FIRE RETARDANT TYPE
M. TOILET
JANITOR
STORAGE
INTERIOR FINISH SCHEDULE-2
MECH ROOM
W. SHOWER
M. SHOWER
W. TOILET
EMPLOYEE LOCKER/DIN
COOLER
LIQUOR STORAGE
149 CLEANGCWTQTBKITCHEN
SSM-1 SOLD SURFACE MATERIAL
FORMICA AT BASE
WC-1
CONCCONC CMU-- - - -- - - - - - - - -
- - - -FCT GWB GWB* PAINT PT-2 GWB* : WATERPROOF TYPE
- - - -FCT GWB GWB* PAINT PT-2 GWB* : WATERPROOF TYPE
GCWT
GCWT
-* : MATCH TO EXST CEILING HGT
-* : MATCH TO EXST CEILING HGT
CLEAN
CLEAN
CLEAN
CLEAN
- - - -FCT GWB GWB* PAINT PT-2 GWB* : WATERPROOF TYPE
- - - -FCT GWB GWB* PAINT PT-2 GWB* : WATERPROOF TYPE
GCWT
GCWT
-* : MATCH TO EXST CEILING HGT
-* : MATCH TO EXST CEILING HGT
CLEAN
CLEAN
CLEAN
CLEAN
- - - -FCT GWB GWB* PAINT PT-2 GWB* : WATERPROOF TYPEGCWT- - - - -* -* : MATCH TO EXST CEILING HGTCLEAN CLEAN
- CLEAN - - - - - -* -* : MATCH TO EXST CEILING HGT
- - GWB GWB* PAINT PT-2GWBQT - - QTBCLEAN CLEAN - -*PAINT PT-1
- - METMETQT - - QTB- - -- - - - - -
QT - -CLEAN - CLEAN - -
GCWT
GWB/
PAINT PT-2 -* -* : MATCH TO EXST CEILING HGT
QT - CLEAN - - CLEAN -
CMU
GWB/
-/- GWB* GWB* : FIRE RETARDANT TYPEPAINT PT-2 -* -* : MATCH TO EXST CEILING HGT
QT - CLEAN - - CLEAN - - -
GWB
ACST/
GWB
GWB/
PAINT PT-2 -*
SSMW-1 SOLD SURFACE MATERIAL
FORMICA AT WAINSCOT
PT-1
OR APPROVED EQUAL
WHITE
MT 410
"KCC MITONE"
603MM x 603MM x 15MM THK
ACOUSTICAL CEILING TILE
OR APPROVED EQUAL
ON OAK WOOD
WOOD FINISH, COLOR: NATURAL FINISH
OR APPROVED EQUAL
MDF PANEL W/AL CLIP
FIRE RETARDANT 12THK
MATCH TO EXST WALL PANEL
OAK, NATURAL VARNISH FINISH,
WOOD WALL PANEL
OR APPROVED EQUAL
EX8816-N/WHITE
LATEX, INTERIOR
ANTI-MOLD & MILDEW
KCC SUPRO HOME & WELLBEING
PAINT COLOR
OR APPROVED EQUAL
EX8816-N/PALEBEIGE
LATEX, INTERIOR
ANTI-MOLD & MILDEW
KCC SUPRO HOME & WELLBEING
PAINT
OR APPROVED EQUAL
ROUND STRAIGHT-RG 6006(W2)
NATURAL VARIATIONS, LIGHT CHERRY (NLC)
WOODWORKS, TEGURAR
ARMSTRONG
WOOD CEILING SYSTEM W/FRAMES
OR APPROVED EQUAL (USER SELECTION)
OR APPROVED EQUAL (USER SELECTION)
1200 x 600 x 4.8 THK
NON GLOSS, NON-SLIP,
MELBOURNE SERISE, M01,
NEXT TILE,
PORCELAIN TILE
FLOOR CERAMIC TILE
OR APPROVED EQUAL (USER SELECTION)
OR APPROVED EQUAL (USER SELECTION)
F9485, NERO GRAFITE, 13THK
F3459, SOAPSTONE SEQUOIA, 13THK
STORAGE
FLOOR CERAMIC TILE
GWB* : FIRE RETARDANT TYPE -* : MATCH TO EXST CEILING HGT
-* : MATCH TO EXST CEILING HGT AND DROP CEILING HGT
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
REMARKS
DOOR DIMENSION
WIDTH
MATERIAL
D1 A
DOOR
TYPE
DOOR
NOS.
ROUGH OPENING
WIDTH HEIGHT
HDW
SET
THICKHEIGHT NO (HR)
RATED
FIRE
LOUVERGLAZING
CUT
UNDER
FRAME
D2
D3
D4
D5
D6
D7
C
D8 C STEEL
STEEL
DOOR
23843760 2447 1980 - -1
D
DOOR / WINDOW / LOUVER SCHEDULE DOOR/ WINDOW / LOUVER ELEVATIONS
44.524382463
WOOD -
AL AL 1)
AA
C D
STEEL 344.52133800 2200 700 -WOOD
FACTORY FINISH
(OAK, NATURAL VARNISH)
& STL FRAME
WOOD SOLID CORE DOOR
1016 914 - * SOUNDPROOF DOOR, STC-25
900600ALGLASSE - -------W1
E
WOOD
: 40.6 KPA
- PEAK IMPULSE
: 210 KPA-MS
PRESSURE
- PEAK REFLECTED
A-15
ARCHITECTURAL
B
EQ DO EQ
A 23843760 2447 1980 - -1 -AL AL 1)-
1) 26.75THK LAMINATED/INSULATED GLASS
1) 26.75THK LAMINATED/INSULATED GLASS
B 23843760 2447 1980 - -2 -AL AL 1)- 1) 8.75THK LAMINATED GLASS
W/ TEMPERED GLASS
DOOR & FRAME
ANODIZED AL BLAST RESISTANT
B 23843760 2447 1980 - -2 -AL AL 1)- 1) 8.75THK LAMINATED GLASS
STEEL 4D 44.521331600 2200 1500 - - 3/4-WOOD
544.521331600 2200 1500 -
D9 C STEEL 644.521002200 - -WOOD -1000 900 - * SOUNDPROOF DOOR, STC-25
C STEEL 744.521002200 - -WOOD -1000 900 - * SOUNDPROOF DOOR, STC-25D10
FACTORY FINISH
(OAK, NATURAL VARNISH)
& STL FRAME
WOOD SOLID CORE DOOR
AL FIXED WINDOW
KEY BOX : WALL MOUNTED KEY BOX E83513.
COORDINATING WITH THE USER FOR APPROVAL BY COR.
THE CONTRACTOR SHALL SUBMIT MASTER KEYING CHART, 4.
5.
6.
8.
9.
7.
HEAT GAIN AND FIRERATED.
WHITE OR LIGHT BEIGE TO MAXIMIZE REFLECTANCE AND MINIMIZE
BE EQUIPPED WITH HORIZONTAL MINI BLINDS. COLOR SHALL BE
WINDOWS IN ALL AREAS WHERE FUNCTIONALLY WARRANTED SHALL
1.
2.
NATURAL COLOR FINISH W/ QUARTER SLICED OAK.
ALL WOOD FLUSH DOORS SHALL BE FINISHED FACTORY COATED
10.
FABRICATION AND INSTALLATION
SHALL BE APPROVED BY THE CONTRACTING OFFICER BEFORE
DOORS AND ALUMINUM WINDOWS AS ACTUAL SIZE, AND DRAWINGS
THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL
HIGH QUALITY AND GRADE PRODUCTS WITH APPROVAL TO COR.
& QUALITY ARE NOT REQUIRED. BUT CONTRACTOR SHOULD INSTALL
AN EXACT MATCH OF THE MANUFACTURERS FUNCTION, GRADE, COLOR,
AND ARE NOT INTENDED TO LIMIT SELECTIONS OF PRODUCTS.
MANUFACTURERS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY
( SHGC : MAX 0.4 )
+ 6 THK TINTED LOW-E TEMPERED GLASS
+ 12 THK AIR SPACE
: 8.75 THK CLEAR LAMINATED GLASS
TYPICAL INSULATED/LAMINATED GLASS FOR WINDOWS
LAMINATED GLASS : 8.75 THK CLEAR LAMINATED GLASS
- WDMA TM-8 HINGE LOADING TEST METHOD
- WDMA TM-7 CYCLE SLAM TEST METHOD
2014 O&MA SPECIFICATIONS.
INDICATED ON SECTION 08 14 00, WOOD DOORS,
SHALL SUBMIT CERTIFICATIONS AND TEST REPORTS FOR APPROVAL AS
ALL WOOD DOORS SHOULD BE TESTED AS FOLLOWING,AND CONTRACTOR
BLAST AL DOOR & WINDOW GLASS SHALL BE PROVIDED BY MFR PER SPEC.
BLAST AL DOOR & WINDOW FRAME CONNECTION REQUIREMENTS SHALL BE
PROVIDED FOR AL GLAZED DOORS & WINDOWS PER SPEC.
11.
DOOR & WINDOW NOTES
1 THRESHOLD C39150
HDW-1
ADJUSTABLE ASTRAGAL, ROY835
ROY 435 FOR SILL
WEATHERSTRIP ROY 165 FOR HEAD & JAMB
HDW-2
BY BLAST DOOR MFR
NOTE : VERIFY ALL HARDWARE
(90° OPEN HOLD)
W/PIVOT C07121
FLOOR CLOSERS C06041
(THERMAL BREAK TYPE)
W/ INSULATED GLASS
(DARK BRONZE COLOR)
ANODIZED AL DOOR & FRAME
2 DUST PROOF STRIKES L04011
DOOR STOP L021612
1 THRESHOLD C39150
(90° OPEN HOLD)
W/PIVOT C07121
FLOOR CLOSERS C06041
DOOR STOP L021612
THRESHOLD BLAST DOOR MFR
(MORDEN TYP BAR/LEVER TYP HANDLE)
EXIT DEVICE TYPE 2-FUNCTION 08
(MORDEN TYPE BAR/LEVER TYP HANDLE)
EXIT DEVICE TYPE 2-FUNCTION 01 1
(MORDEN TYP BAR/LEVER TYP HANDLE)
EXIT DEVICE TYPE 2-FUNCTION 08
(MORDEN TYPE BAR/LEVER TYP HANDLE)
EXIT DEVICE TYPE 2-FUNCTION 01
HDW-3
THRESHOLD J32100
KICK PLATE J102, SST
DOOR STOP L02161
CLOSER C02011
(W/ LEVER HANDLE)
LOCKSET 4000-1, F82
HINGES A5111, 114x114
HDW-4
1 THRESHOLD 32100
DOOR CLOSER C02011
LOCKSET 4000-1, F86
HINGES A5111, 114x114 (NRP)
DOOR STOP L021612
2 FLUSH BOLTS L04201
2 KICK PLATE J102, SST
HDW-5
DOOR STOP L021612
2 FLUSH BOLTS L04201
2 KICK PLATE J102, SST
THRESHOLD 32100
DOOR CLOSER C02011
LOCKSET 4000-1, F82
HINGES A5111, 114x114
DUST PROOF STRIKES L040111 DUST PROOF STRIKES L040111
HDW-6
DOOR STOP L021611
1 KICK PLATE J102, SST
THRESHOLD 32100
DOOR CLOSER C02011
KEY OVERRIDE (3KEYS)
KABA SIMPLEX MODEL 8148
(W/ LEVER HANDLE)
BUTTON TYPE
LOCKSET MECHANICAL PUSH
HINGES A5111, 114x114
HDW-7
THRESHOLD J32100
KICK PLATE J102, SST
DOOR STOP L02161
CLOSER C02011
(W/ LEVER HANDLE)
LOCKSET 4000-1, F82
HINGES A5111, 114x114
ROY 435 FOR SILL
ROY 155 FOR HEAD & JAMB
SOUND PROOF SEAL
ROY 435 FOR SILL
ROY 155 FOR HEAD & JAMB
SOUND PROOF SEAL1
HARDWARE SCHEDULE
AND HARDWARE SCHEDULE
DOOR / WINDOW SCHEDULE, ELEVATIONS
(2EA)
400X400
400X400
HARDWARE NOTES
1.REPLACE ALL THRESHOLDS AT COORIDOR TO MEET NEW FLOOR FINISH.
BUILDING S-533
REPAIR FIRE PROTECTION SYSTEM