4. B975 Sketch.pdf

PDF 239 KB Posted

Attached to
Repair Sanitary Sewer Lines at Osan AB, Korea (MATOC Work Plan only)
Solicitation number
W90VN6-24-R-0023
Issued by

About this file

This document appears to be a set of plumbing plans and a related federal contract opportunity for repairing sanitary sewer lines at Osan Air Base in Korea.

The plumbing plans show the kitchen area plumbing layout, including pipe sizes, equipment schedule, and plumbing requirements for sinks, stops, traps, and waterproofing. The related federal contract opportunity is Solicitation W90VN6-24-R-0023 for the "Repair Sanitary Sewer Lines at Osan AB, Korea" under a Multiple Award Task Order Contract (MATOC). The opportunity is for MATOC contractors in Area III, Suwon AB and Osan AB, Korea. The solicitation and drawings are attached. No additional details on the contract requirements, timelines, pricing, or set-asides are provided in the given information.

View the file

Other files

File Type Posted
Amendment W90VN6-24-R-0023-0001.pdf PDF
5. B975 As-built.pdf PDF
1. Drawings SMYU 24-1056.pdf PDF
3. B828 95_ Drawings.pdf PDF
2. B828 Sketch.pdf PDF
Submittal Register.pdf PDF
W90VN6-24-R-0023.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

H

G

F

E

D

C

B

A

2" x-:5' INCREASER- 3' V.T.R. --�

SEE 11\

\d.9-'

SEE@

WATER HAMMER ARRESTOR

(P.D.1. "A" TYPE) (TYP. OF 2)

____ : _______ -A w 1" ----- _J_ __ � -- _t'' -----

4• 1 Ill ..L--lt-

L SEE CIVIL DWG.

FOR CONT.

____ .J

CD

IX

1 KITCHEN AREA PLUMBING PIPING PARTIAL PLAN

1014 SCALE·

D.C.W. & D.H.W. PIPING

1/4" - 1'-o·

VENT & WASTE PIPING

2 KITCHEN AREA PLUMBING PIPING ISOMETRIC DIAGRAM

1014 NOT TO SCALE

7 6 5

SYMBOL

CD -

CD --

1- ---

Q'TY

2 1

KITCH EN EQUIPMENT SCHEDULE

DESCRIPTION

CONDENSING UNIT

WALK-IN COOLER

BLOWER COIL

WALK-IN FREEZER

BLOWER COIL

MOP SINK

FAUCET

HAND SINK

FAUCET

3-COMPARTMENT SINK

PRE-RINSE FAUCET

FAUCET

BOOSTER HEATER

2-COMPARTMENT PREP SINK

FAUCET /PRE-RINSE

HOT FOOD WELLS

FILL FAUCET

DRIP TROUGH

ICE & BEVERAGE DISPE NSER

JUICE DISPENSER

GRAPHIC SCALE

c.w H.W

WASTE

-- E �DiR _ IND VENT

1·

1·

3• - 1-1/2"

REMARKS

WALK-IN FREEZER

WALK-IN - - -COOLER

H

L_ ___ - - - - - G

1/2" 1/'Z -

- - 1-1/2"

1/2" 1/'Z -

-r (-:5') --

1/2" 1/'Z -

3/4" 3/4" -

- - 1-1/2"(2')

1/'Z 1/'Z -

- 1-1/2"

- 1-1/2"

- 3/4"

- 1-1/2"

9KW,

DEGREES

20BV/

3�/ 60 H z

- - - - 1· PROVIDE SHUT-OFF VA LVE

1/2" 1/'Z - - -

- 1·

1/2" - - 3/4" -

& 3LB"_ --- - --

1/4" - - - -

KITCHEN PLUMBING REQUIREMENTS

1. SINKS (]:)!c@SHALL BE FURNISHED WITH 1-1/'Z WASTE

CONNECTIONS (2" ROTARY WASTE VALVES) ARE COMPLETE WITH

1-1 /2" THREADED WASTE CONNECTION ADAPTER OR TAILPIECE.

2 WHERE REQUIRED, STOPS (SHUT-OFF VALVES) AND CHECK

VALVES ARE TO BE FURNISHED AND INSTALLED ON ALL

HOT AND COLD WATER LINES AT EACH PIECE OF EQUIPMNET.

3. ALL PIPING TO BE CONCEALED WHERE POSSIBLE AND ALL

EXPOSED PIPING AND FITTINGS TO BE CHROME PLATED,

STAINLESS STEEL, OR CHROME PLATED SLEECES.

4. CODE PATTERN "P" TRAPS SHALL BE CHROME PLATED

ADJUSTABLE CAST BRASS, UNIFORM CODE PATTERN.

5. CONTRACTOR SHALL BE RESPONSIBLE FOR WATERPROOFING

ALL OF THE PENETRATIONS. ALL FLOOR OPENINGS ARE TO BE

SEALED WATERTIGHT BY MEANS OF SLEEVES OR OTHERWISE.

FLOOR SLEEVES SHALL EXTEND 1" ABOVE FINISHED FLOOR.

PIPING THROUGH WALLS OR FLOORS SHALL BE SEALED VERMIN

PROOF.

6. ALL HORIZONTAL PIPING LINES AS EXTENDED AND CONNECTED

TO EQUIPMENT SHALL RUN AT THE HIGHEST POSSIBLE

ELEVATIONS, AND NOT LESS THAT ff' ABOVE THE FLOOR, SO AS

TO INSURE AND PROVIDE CLEARANCE FOR CLEANING AT ALL

SUCH LOCATIONS. AT WALL OR COLUMN LOCATIONS, ALL PIPING

ROUGH-INS SHALL BE STUBBED IN WALLS WHEREVER POSSIBLE.

7 CONTRACTOR TO FURNISH AN1) INSTALL AN APPROVED VACUUM

BREAKER AND FILTER- ON WATER LINE TO COFFEE BREWERS.

I I

F

E

D

C

; I I , ) '

1---' -+==1==---=-'-'-'::..__:___::_ _ _,__----=--- -=---=-·::..:··=-·=-=·=-·-:::;·=-=-· --+----f---1--+- ---1 B----- -- --- -'

DA TE BY CHK APVO REV L TR ZONE

U S. ARMY ENGINEER

DIS'IRICT r AR EAST

A-e: CONT'RACT NO NAFKF"J-9�-C-0001

AMKOR I SAC - A JOINT v!Nl'URE

ARCHl1'ECTS ENGINE�'!!

DESCRIPTION

RE\IISIONS

U. S. ARMY ENGINEER DIVISION, PACIFlC OCEAN

CORPS Or ENGINEERS

HONOLULU, HAWAII

FY95 NAAF SMYU 93-5001,

CONSTRUCT BOWLING CENTER

OSAN AB

MECHANICAL

KITCHEN AREA PLUMBING PIPING

PARTIAL PLAN & ISOMETRIC DIAGRAM

SI DA 1'[ LOCATION

F �UG l\ 8 1! g / OSAN, KOREA A

2' 0 2' 4' 5· 8' 1 o· 1/4" = !' - O' - - -

LOC CODE �RAWING NUMBER

PREFi� a.ASS T't'f'E SEOUE:Mct SHEET

8913 AF 31 09 0163 M014 @

3 2 1

1365729901U Polygon

1365729901U Line

1365729901U Text Box

SEE C-002

1365729901U Line

1365729901U Text Box

REMOVE AND REPLACE

W/ NEW 4" LINE

1363639751U Text Box

REPLACE EXISTING FLOOR AND DRILLIG/GROUTING HOLE FOR NEW 4" LINE

1363639751U Polygonal Line

File details come from the government source that posted it. Updated .