This is a final request for proposal for the installation of a Digital Air-Ground Integration Range at Fort Knox, Kentucky. The U.S. Army seeks proposals to provide IT equipment utilizing the Digital Range Training System Live Training Transformation software, an After Action Review system, vehicle and dismounted player units, and a radio communication system. Additional features already under separate contract include stationary and moving armor and infantry targets, an air/ground integration village, an aerial weapons scoring system, and long-range thermal field cameras. Proposals are due by the fourth quarter of fiscal year 2022, with an anticipated award date also in the fourth quarter of 2022. The Department of the Army Materiel Command Contracting Command Orlando Contracting Center will oversee the contract. Questions and answers submitted in response to the draft RFP are included as an attachment.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PRF-PT-767

Cage 57039 Version: 1.1 6 June 2022

DIGITAL RANGE TRAINING SYSTEMS (DRTS)

DISMOUNTED TRACKER (DMT)

PERFORMANCE SPECIFICATION

U.S. Army Program Executive Office for Simulation, Training and Instrumentation (PEO STRI)

12211 Science Drive Orlando, FL 32826-3276

Engineering:

Prepared By: ____________________ Approved by: ______________ Nicole Steib James Todd Lead Systems Engineer, PdM LTS Chief Engineer, PdM LTS, FOT

Distribution Statement A:

Approved for Public Release, Distribution is Unlimited

Version: 1.1

Revision History

Date Version Author Section Revision Description 18 Nov 2021 1.0 DRTS

Team All DRTS DMT Spec

6 June 2022 1.1 DRTS Team

3.7.3.1, 3.7.3.2

Updated Storage and Operating Temperature Parameters

Version: 1.1

Table of Contents

1 INTRODUCTION

2 APPLICABLE DOCUMENTS

2.1 MILITARY SPECIFICATIONS, STANDARDS, AND HANDBOOKS

2.2 OTHER GOVERNMENT DOCUMENTS

3 DMT REQUIREMENTS

3.1 GENERAL DESCRIPTION

3.2 DISMOUNTED TRACKER (DMT) REQUIREMENTS

3.3 DMT BUILT-IN TEST (BIT)

3.4 DMT BATTERIES

3.5 DMT BATTERY CHARGER

3.6 ACCESSIBILITY

3.7 DMT PHYSICAL CHARACTERISTICS

3.7.1 WEIGHT

3.7.2 FINISH

3.7.3 ENVIRONMENTAL REQUIREMENTS

3.7.3.1 STORAGE

3.7.3.2 OPERATING TEMPERATURE

3.7.3.3 HUMIDITY

3.7.3.4 SEA COAST/SALT SPRAY

3.7.3.5 ARID/DESERT CONDITIONS

3.7.3.6 RAIN

3.7.3.7 SUBMERSION

3.7.3.8 SHOCK

3.7.3.9 VIBRATION

3.8 DMT SOFTWARE (SW)

3.9 DMT POSITION DATA

3.9.1 DMT GPS RECEIVER

3.9.2 ACCURACY

3.9.3 UPDATE AND REPORTING RATE

3.10 SAFETY REQUIREMENTS

3.11 DMT ELECTROMAGNETIC COMPATIBILITY (EMC)

3.11.1 ELECTROMAGNETIC ENVIRONMENTAL EFFECTS (E3)

3.11.2 INTRA-SYSTEM EMC

3.11.3 INTER-SYSTEM EMC

3.11.4 NON-DEVELOPMENTAL ITEMS (NDI) AND COMMERCIAL ITEMS

3.11.5 LIFE CYCLE, E3 HARDNESS

3.11.6 ELECTROMAGNETIC RADIATION HAZARDS (EMRADHAZ)

3.12 TRANSMITTER/RECEIVER

3.13 DMT TRANSMIT POWER OUTPUT

4 VERIFICATION

Version: 1.1

4.1 ACCEPTANCE TEST STRUCTURE

4.2 DMT REQUIREMENTS

4.3 DMT BUILT IN TESTS (BIT)

4.4 DMT BATTERIES

4.5 DMT BATTERY CHARGER

4.6 ACCESSIBILITY

4.7 DMT PHYSICAL CHARACTERISTICS

4.7.1 WEIGHT

4.7.2 FINISH

4.7.3 ENVIROMENTAL REQUIREMENTS

4.7.3.1 STORAGE

4.7.3.2 OPERATING TEMPERATURE

4.7.3.3 HUMIDITY

4.7.3.4 SEA COAST/SALT SPRAY

4.7.3.5 ARID/DESERT CONDITIONS

4.7.3.6 RAIN

4.7.3.7 SUBMERSION

4.7.3.8 SHOCK

4.7.3.9 VIBRATION

4.8 DMT SW

4.9 DMT POSITION DATA

4.9.1 DMT GPS RECEIVER

4.9.2 ACCURACY

4.9.3 UPDATE AND REPORTING RATE

4.10 SAFETY REQUIREMENTS

4.11 DMT ELECTROMAGNETIC COMPATIBILITY

4.11.1 ELECTROMAGNETIC ENVIRONMENTAL EFFECTS (E3)

4.11.2 INTRA-SYSTEM EMC

4.11.3 INTER-SYSTEM EMC

4.11.4 NON-DEVELOPMENTAL ITEMS (NDI) AND COMMERCIAL ITEMS

4.11.5 LIFE CYCLE, E3 HARDNESS

4.11.6 ELECTROMAGNETIC RADIATION HAZARDS (EMRADHAZ)

4.12 TRANSCEIVER/RECEIVER

4.13 DMT POWER OUTPUT

APPENDIX A: DRTS SYSTEM DIAGRAM

APPENDIX B: ACRONYM LIST

Version: 1.1

1 INTRODUCTION

This document provides the detailed performance requirements for the Dismounted Tracker (DMT). The DMTs are used within the DRTS implementation to provide near real-time horizontal and vertical position location data for dismounted troop tracking and display on the DRTS Situational Awareness Workstation (SAW). The DMTs are intended to provide tracking data once the troops dismount from transport vehicles.

This specification provides requirements for dismounted applications. The DMTs communicate with the DRTS system through a standalone Very High Frequency (VHF) radio network band between 220 and 300 MHz. The range infrastructure handles communications from the DMT to the Control Tower (CT).

This document defines one subsystem element of an entire DRTS solution. Therefore, unless procured separately, the requirements in this document must be implemented in conjunction with the DRTS Performance Specification PRF-PT-768 to form a complete operational capability.

Any noted technical gap or inconsistency are not intended, and if noted, shall be brought to the attention of the Government for reconciliation.

Figure 1: DMT Diagram

Version: 1.1

2 APPLICABLE DOCUMENTS

In the event of a conflict between documents referenced herein and the contents of this Performance Specification, the contents of this Performance Specification shall be the governing requirement.

2.1 MILITARY SPECIFICATIONS, STANDARDS, AND HANDBOOKS

The following specifications, standards, and handbooks form a part of this document to the extent specified herein.

Number Title MIL-STD-810G Environmental Engineering Considerations And

Laboratory Tests MIL-STD-461 Requirements for Control of Electromagnetic Interference

Characteristics of Subsystems and equipment MIL-STD-2401 DOD Standard Practice, World Geodetic System (WGS

84) GPS SPS PS 5th Edition Global Positioning System Standard Positioning Service

Performance Standard Table 1: Specifications, Standards and Handbooks

2.2 OTHER GOVERNMENT DOCUMENTS

The following other Government documents, drawings, and publications form a part of this specification to the extent specified herein.

Document Number Document Title PRF-PT-768 Digital Range Training Systems (DRTS) Performance

Specification.

Table 2: Other Government Documents

Copies of specifications, standards, and drawings may be obtained as directed by the Contracting Officer (PCO).

3 DMT REQUIREMENTS

The following paragraphs describe the specific detailed performance requirements for the Soldier’s DMT. In the event of a conflict between this document and the DRTS Performance Specification PRF-PT-768, the DRTS Performance Specification takes precedence.

3.1 GENERAL DESCRIPTION

The DMT generates Time-Space Position Information (TSPI) using a Global Positioning System (GPS) receiver and transmits data to the Control Tower. The DMT receives configuration and control data from the Control Tower. Each DMT generates Common Training Instrumentation Architecture (CTIA) event data in accordance with the Player Unit (PU) CTIA Interface Control Document (ICD).

http://164.214.2.59/publications/specs/printed/2401/2401.pdf

Version: 1.1

3.2 DISMOUNTED TRACKER (DMT) REQUIREMENTS

The DMT shall comply with the PU CTIA ICD and the following requirements. The DMT shall:

a. Be configurable and controllable from the Control Tower.

b. Utilize GPS in accordance with MIL-STD-2401 and GPS SPS PS 5th Edition for position reporting.

c. Not hinder the dismount Soldier from unfettered operations of their weapons and/or other tactical equipment in accordance with standard operational tactics/doctrine.

d. Operate in the training environment IAW the Environmental Parameters defined in section 3.7.3.

e. Operate on a network capable of supporting 28 DMTs in simultaneous use.

f. Be packaged such that all components are provided as one unit.

g. Be IP66 rated, to include all component connectors.

3.3 DMT BUILT-IN TEST (BIT)

The DMT BIT capability shall:

a. Perform built-in fault detection for all DMT equipment to detect proper performance, performance degradation and failures.

b. Identify faults other than power supply or Circuit Card Assembly (CCA) isolated.

c. Automatically run during power on.

d. Provide results in less than 5 minutes after initiation.

e. Relay faults/status back to the Control Tower.

3.4 DMT BATTERIES

Batteries used to power DMT components shall:

a. Be accessible by the operator/maintainer without need for any special tools.

b. Be commercially available and safe in the operational environment.

c. Have a life expectancy of a minimum of 3 years.

d. Provide the capability to operate for a minimum of 8 hours.

3.5 DMT BATTERY CHARGER

The DMT Battery Charger shall:

a. Use a standard 115V/20A wall plug power source.

b. Charge batteries in less than 4 hours from fully discharged to fully charged.

c. Have the ability to charge up to 28 DMT batteries simultaneously.

3.6 ACCESSIBILITY

The DMT shall allow replacement of the DMT batteries by the maintenance personnel in less than 2 minutes. The DMT shall retain configuration settings during the replacement of DMT primary batteries.

Version: 1.1

3.7 DMT PHYSICAL CHARACTERISTICS

3.7.1 WEIGHT

The DMT’s weight shall not exceed 2 pounds including radio, batteries, antennas, cables, carrying case, and any other Soldier worn components.

3.7.2 FINISH

All exterior surfaces of the DMT shall be treated to resist corrosion and deterioration due to exposure to the elements. The DMT and its exterior connections shall be properly constructed/sealed to avoid all water intrusion. The DMT shall be designed to avoid dissimilar metal galvanization.

3.7.3 ENVIRONMENTAL REQUIREMENTS

All exposed DMT devices, including connectors, cables, systems and subsystems shall be capable of fully functioning without degradation in performance when operated and/or stored in the identified environmental conditions. Environmental exposure shall not cause binding, blistering, or deformation of devices, or the cause of degraded, partial, unsafe, or failed operations. All components shall be designed and configured to withstand the typical stresses and environments associated with handling, transportation, and reconfiguration of the system.

3.7.3.1 STORAGE

All DMT field components shall be capable of surviving prolonged storage at -20 to 50 degrees Celsius.

3.7.3.2 OPERATING TEMPERATURE

All DMT field components shall be capable of operations at ambient temperatures between -20 and 60 degrees Celsius. All DMT field components shall be capable of operations while exposed to direct solar effects, up to 365 days per year. Solar effects are in addition to the ambient temperature requirements, and may result in greater internal temperatures than even storage conditions.

3.7.3.3 HUMIDITY

All DMT field components shall be capable of operations in humid conditions up to 100% (condensing and non-condensing), at 50 degrees Celsius.

3.7.3.4 SEA COAST/SALT SPRAY

All DMT field components shall be capable of operations in seacoast meteorological (salt atmospheric) conditions.

3.7.3.5 ARID/DESERT CONDITIONS

All DMT field components shall be capable of operations during and after exposure to dusty desert conditions. These conditions include both the effects of blowing sand and dust.

Version: 1.1

3.7.3.6 RAIN

All DMT field components shall be capable of operations during and after exposure to rain and blowing rain at a rate up to 4 inches per hour for a period of two hours with up to 40 mph winds. After exposure, any residual water will dissipate in 22 hours without any operator action. Equipment shall be capable of withstanding daily exposure to this rain cycle.

3.7.3.7 SUBMERSION

All Soldier wearable DMT components shall be capable of being completely submerged to a depth of 1 meter for a minimum of 30 minutes without failure due to moisture intrusion.

3.7.3.8 SHOCK

The Soldier wearable DMT components shall not be damaged when exposed to normal handling and dropping shock/impacts.

3.7.3.9 VIBRATION

The Soldier wearable DMT components shall not be damaged when exposed to handling and transportation vibration effects.

3.8 DMT SOFTWARE (SW)

The DMT shall be configurable through the Test and Operation Maintenance Console (TOMC) software application as defined in the DRTS Performance Specification.

3.9 DMT POSITION DATA

The DMT shall use GPS as the primary source of information for deriving time and position data IAW MIL-STD-2401, and GPS SPS PS 5th Edition.

3.9.1 DMT GPS RECEIVER

The DMT GPS receiver shall:

a. Provide for signal acquisition, signal tracking, signal processing, estimation, and self-test functions to derive the position data.

b. Be capable of self-initializing and acquiring the GPS satellite signals within 6 minutes from the time the DMT receiver is powered.

c. Reacquire the lost satellite signal and reestablish position location within 5 seconds after GPS signal has been reacquired.

3.9.2 ACCURACY

DMT horizontal (in both dimensions) and vertical position accuracy shall be equal or better than 3 meters (3m) Root Mean Squared (RMS). The DMT accuracy shall be maintained over the entire coverage area.

Version: 1.1

3.9.3 UPDATE AND REPORTING RATE

Position location reporting rates shall be controllable within the exercise scenario function based on elapsed time and distance traveled from last reported position. The DMT shall provide elapsed time reporting rates, which are configurable from 5 to 180 seconds with 5-second increments. The DMT shall provide distance traveled reporting rates from 5-meter (5m) to 10-meters (10m) with 1-meter (1m) increments.

3.10 SAFETY REQUIREMENTS

The DMT shall be safe to operate IAW DRTS Performance Specification PRF-PT-768.

3.11 DMT ELECTROMAGNETIC COMPATIBILITY (EMC)

The DMT shall be electromagnetically compatible with itself and adjacent electrical and electromechanical environment in fulfillment of Performance Specification PRF-PT-768.

3.11.1 ELECTROMAGNETIC ENVIRONMENTAL EFFECTS (E3)

The DMT components shall be electromagnetically compatible among all subsystems and equipment found at the training ranges and with electromagnetic environment external to the HW. All equipment (NDI, COTS, modified COTS, new design) shall operate in the electromagnetic environment (EME) described below without being a source of electromagnetic interference or a victim of site/location generated electromagnetic emissions, whether radiated or conducted.

The DRTS site is a high electromagnetic noise environment for radiated energy. The DRTS site is an active military training range with an active airfield operation. The DRTS site contains electromagnetic effects from licensed/authorized RF emitters, lightning storms, power line transients, and electrostatic fields generated by human operators and maintainers.

3.11.2 INTRA-SYSTEM EMC

The DMT shall be electromagnetically compatible with itself such that system operational performance requirements can be met.

3.11.3 INTER-SYSTEM EMC

The DMT shall be electromagnetically compatible with its defined EME such that the system operational performance requirements can be met. Inter-system EMC covers compatibility with, but is not limited to, the operational site EME, adjacent equipment, and friendly emitters (CB, UHF, VHF, cellular, etc.).

3.11.4 NON-DEVELOPMENTAL ITEMS (NDI) AND COMMERCIAL ITEMS

NDI and commercial items shall be compliant with the E3 requirements to ensure that the system operational performance requirements are met.

Version: 1.1

3.11.5 LIFE CYCLE, E3 HARDNESS

The DMT operational performance and E3 requirements shall be applicable throughout the rated life cycle of the equipment. The DMT shall detect degradation that would affect the safe E3 operations of the DMT at the installation.

3.11.6 ELECTROMAGNETIC RADIATION HAZARDS (EMRADHAZ)

The DMT shall be designed to ensure that personnel, fuels, and ordnance are protected from hazardous effects of electromagnetic radiation.

3.12 TRANSMITTER/RECEIVER

The DMT shall provide near real-time data transmission. The DMT transmitter/receiver shall comply with frequency allocations and spectrum at the intended installation. The DMT shall have a unique access identifier and automatically enter the communication network when the transceiver is on.

3.13 DMT TRANSMIT POWER OUTPUT

The DMT’s transmission power output shall not exceed 2 Watts RMS. The DMT’s transmission power shall not exceed safety thresholds for man-worn transceivers.

4 VERIFICATION

This paragraph includes all verifications to be performed to determine that the system offered for acceptance conforms to all requirements in paragraph 3 of this specification.

Unless otherwise specified, all inspections shall be performed in prevailing environmental conditions that define normal range operations.

Methods of Verification include:

a. Examination: An element of verification and inspection consisting of investigation, without the use of special laboratory appliances or procedures, of items to determine conformance to those specified requirements, which can be determined by such investigations.

Examination is generally nondestructive and typically includes the use of sight, hearing, smell, touch, and taste; simple physical manipulation;

mechanical and electrical gauging and measurement; and other forms of investigation.

b. Analysis: An element of verification that uses established technical or mathematical models or simulations, algorithms, charts, graphs, circuit diagrams, or other specific scientific principles and procedures to provide evidence that state requirements were met.

c. Demonstration: An element of verification that generally denoted the actual operation, adjustment, or re-configuration of items to provide evidence that the designed functions were accomplished under specific

Version: 1.1 scenarios. The items may be instrumented and quantitative limits of performance monitored.

d. Test: An element of verification and inspection that generally denoted the determination, by technical means, of the properties or elements of items, including functional operation, and involves the application of established scientific principles and procedures.

e. Certification: An element of verification that that generally denotes or documents the prior conduct of formal test verification, and relies on documented test results, performance data, analytical data, or vendor documentation. The items require that the contractor certify that the requirements have been met.

4.1 ACCEPTANCE TEST STRUCTURE

The System Technical Test (STT) is an on-site test where the contractor and the Government representatives test the system. During the STT, the initial and comprehensive requirements are tested using the test procedure. The STT is conducted before System Operational Test (SOT) to ensure the system is prepared to be tested by the Government. The DMT requirements listed in this specification shall be verified during STT. The STT shall include the following testing, at a minimum, to ensure full coverage of the DMT requirements:

DMT Functional Testing:

The purpose of the DMT test is to verify the DRTS hardware/software interaction with the DMT. The test also verifies that the DRTS software properly displays the DMT GPS position on the SAW map with the proper status and location. The ability to control the DMT using the Command and Control GUI will also be verified.

DMT Coverage Test:

The DMT coverage test ensures the DMT stays connected to the RDCS throughout all areas on the range and reports the GPS location of the DMTs throughout the footprint of the range. The objective is to confirm DMT connectivity to the Hub radio and antenna (usually mounted to the range tower) and successful transmission of position data to the DRTS system throughout all required ranges areas thus making sure the DMT network provides the required coverage. The range will most likely utilize one VHF antenna on the range control tower; however, a repeater could be required to cover some areas downrange.

The contractor will use vehicles and personnel with DMTs to verify coverage. For a six-lane range there will be six vehicles (one per lane) each instrumented with four DMTs to cover the lanes. Four test personnel instrumented with the remaining DMTs will walk the range dismounted test areas. Coverage will be verified by test personnel in the range control tower where they will be monitoring and recording coverage data from the

SAW.

Version: 1.1

4.2 DMT REQUIREMENTS

Requirement: E A D T C The DMT shall comply with the PU CTIA ICD. This requirement shall be verified during the DMT Functional Testing.

X X

The DMT shall be configurable and controllable from the Control Tower. This requirement shall be verified during the DMT Functional Testing.

X

The DMT shall utilize GPS IAW MIL-STD-2401 and GPS SPS PS 5th Edition for position reporting. This requirement shall be verified during the DMT Functional Testing.

X

The DMT shall not hinder the dismount Soldier from unfettered operations of their weapons and/or other tactical equipment in accordance with standard operational tactics/doctrine.

X

The DMT shall be operate in the training environment IAW the Environmental Parameters defined in section 3.7.3. This requirement shall be verified during the DMT Functional Testing.

X X

The DMT shall operate on a network capable of supporting 28 DMTs in simultaneous use. This requirement shall be verified during the DMT Coverage Testing by including all provided DMTs (no more than 28) on the network at the same time.

X X

The DMT shall be packaged such that all components are provided as one unit.

X

The DMT shall be IP66 rated, to include all component connectors.

X X

4.3 DMT BUILT IN TESTS (BIT)

Requirement: E A D T C The DMT BIT capability shall perform built-in fault detection for all DMT equipment to detect proper performance, performance degradation and failures. This requirement shall be verified during the DMT Functional Testing.

X

The DMT BIT capability shall identify faults other than power supply or CCA isolated to an LRU. This requirement shall be verified during the DMT Functional Testing.

X

The DMT BIT capability shall automatically run during Power On. This requirement shall be verified during the DMT Functional Testing.

X

The DMT BIT capability shall provide results in less than 5 minutes after initiation. This requirement shall be verified during the DMT Functional Testing.

X

Version: 1.1

The DMT BIT capability shall relay faults/status back to the Control Tower. This requirement shall be verified during the DMT Functional Testing.

X

4.4 DMT BATTERIES

Requirement: E A D T C Batteries used to power DMT components shall be accessible by the operator/maintainer without need for any special tools.

X

Batteries used to power DMT components shall be commercially available and safe in the operational environment.

X

Batteries used to power DMT components shall have a life expectancy of a minimum of 3 years.

X

Batteries used to power DMT components shall provide the capability to operate for a minimum of 8 hours. This requirement shall be verified during the DMT Functional Testing.

X X

4.5 DMT BATTERY CHARGER

Requirement: E A D T C Use a standard 115V/20A wall plug power source. X The DMT battery charger shall charge batteries in less than 4 hours from fully discharged to fully charged. This requirement shall be verified during the DMT Functional Testing by letting the battery to fully discharge and fully charging it. The use of a stopwatch is required.

X

The DMT battery charger shall have the ability to charge 28 DMT batteries simultaneously.

X

4.6 ACCESSIBILITY

Requirement: E A D T C The DMT shall allow replacement of the DMT batteries by the maintenance personnel in less than 2 minutes. This requirement shall be verified during the DMT Functional Testing by performing a battery replacement. The use of a stopwatch is required.

X

The DMT shall retain configuration settings during the replacement of DMT primary batteries. This requirement shall be verified during the DMT Functional Testing.

X X

Version: 1.1

4.7 DMT PHYSICAL CHARACTERISTICS

4.7.1 WEIGHT

Requirement: E A D T C The DMT’s weight shall not exceed 2 pounds including radio, batteries, antennas, cables, carrying case, and any other Soldier worn components. This requirement shall be verified during the DMT Functional Testing by using a scale to weigh the DMT unit (all components included).

X

4.7.2 FINISH

Requirement: E A D T C All exterior surfaces of the DMT shall be treated to resist corrosion and deterioration due to exposure to the elements.

X X

The DMT and its exterior connections shall be properly constructed/sealed to avoid all water intrusion.

X X

The DMT shall be designed to avoid dissimilar metal galvanization.

X X

4.7.3 ENVIROMENTAL REQUIREMENTS

Requirement: E A D T C All exposed DMT devices, including connectors, cables, systems and subsystems shall be capable of fully functioning without degradation in performance when operated and/or stored in the identified environmental conditions.

X X

Environmental exposure shall not cause binding, blistering, or deformation of devices, or the cause of degraded, partial, unsafe, or failed operations.

X X

All components shall be designed and configured to withstand the typical stresses and environments associated with handling, transportation, and reconfiguration of the system.

X X

4.7.3.1 STORAGE

Requirement: E A D T C All DMT field components shall be capable of surviving prolonged storage at -20 to 50 degrees Celsius. This requirement shall be tested IAW MIL-STD-810G Method

501.5 (A1) (Non-operating: +71°C) and MIL-STD-810G Method 502.5 (C1) (Non-operating: -33°C). For Commercial Off The Shelf (COTS) products certification will suffice, otherwise for new products test results will be required.

Version: 1.1

4.7.3.2 OPERATING TEMPERATURE

All DMT field components shall be capable of operations at ambient temperatures between -20 and 60 degrees Celsius.

All DMT field components shall be capable of operations while exposed to direct solar effects, up to 365 days per year.

This requirement shall be tested IAW MIL-STD-810G Method

501.5 (A1) (Operating +49°C) and MIL-STD-810G Method

502.5 (C1) (Operating -31°C). For Commercial Off The Shelf (COTS) products certification will suffice, otherwise for new products test results will be required.

X X

4.7.3.3 HUMIDITY

Requirement: E A D T C All DMT field components shall be capable of operations in humid conditions up to 100% (condensing and non-condensing), at 50 degrees Celsius. This requirement shall be tested IAW MIL-STD-810G Method 507.5. For Commercial Off The Shelf (COTS) products certification will suffice; otherwise, for new products test results will be required.

X X

4.7.3.4 SEA COAST/SALT SPRAY

Requirement: E A D T C All DMT field components shall be capable of operations in seacoast meteorological (salt atmospheric) conditions. This shall be tested using a 5% sodium chloride atomized spray IAW MIL-STD-810G, Method 509.5. For COTS products certification will suffice, otherwise for new products test results will be required.

X X

4.7.3.5 ARID/DESERT CONDITIONS

Requirement: E A D T C All DMT field components shall be capable of operations during and after exposure to dusty desert conditions. This requirement shall be tested IAW MIL-STD-810G, Method

510.5. For COTS products certification will suffice, otherwise for new products test results will be required.

X X

4.7.3.6 RAIN

Requirement: E A D T C All DMT field components shall be capable of operations during and after exposure to rain and blowing rain at a rate up to 4 inches per hour for a period of two hours with up to

Version: 1.1

40 mph winds. After exposure, any residual water will dissipate in 22 hours without any operator action. Equipment shall be capable of withstanding daily exposure to this rain cycle. This requirement shall be tested IAW MIL-STD-810G Method 506.5. Those components subjected to the rain test shall not be subjected to the submersion test. For COTS products certification will suffice, otherwise for new products test results will be required.

4.7.3.7 SUBMERSION

Requirement: E A D T C All Soldier wearable DMT components shall be capable of being completely submerged to a depth of 1 meter for a minimum of 30 minutes without failure due to moisture intrusion. Those components subjected to the submersion test shall not be subjected to the rain test. This requirement shall be tested IAW MIL-STD-810G Method 512.5. For COTS products certification will suffice, otherwise for new products test results will be required.

X X

4.7.3.8 SHOCK

Requirement: E A D T C The Soldier wearable DMT components shall not be damaged when exposed to normal handling and dropping shock/impacts. This requirement shall be tested IAW MIL- STD-810G Method 516.6, Procedure I – Functional shock and Procedure IV – Transit Drop (inside transit case). For COTS products certification will suffice, otherwise for new products test results will be required.

X X

4.7.3.9 VIBRATION

Requirement: E A D T C The Soldier wearable DMT components shall not be damaged when exposed to handling and transportation vibration effects. This requirement shall be tested IAW MIL- STD-810G, Method 514.6, Categories 1-5. For COTS products certification will suffice, otherwise for new products test results will be required.

Version: 1.1

4.8 DMT SW

The DMT shall be configurable through the Test and Operation Maintenance Console (TOMC) as defined in the DRTS Performance Specification. This requirement shall be verified during the DMT Functional Testing.

X

4.9 DMT POSITION DATA

Requirement: E A D T C The DMT shall use GPS as the primary source of information for deriving time and position data IAW MIL-STD-2401, and GPS SPS PS 5th Edition. This requirement shall be verified during the DMT Functional Testing.

X X

4.9.1 DMT GPS RECEIVER

Requirement: E A D T C The DMT GPS receiver shall provide for signal acquisition, signal tracking, signal processing, estimation, and self-test functions to derive the position data.

X

The DMT GPS receiver shall be capable of self-initializing and acquiring the GPS satellite signals within 6 minutes from the time the DMT receiver is powered. This requirement shall be verified during the DMT Functional Testing. The use of a stopwatch is required.

X

The DMT receiver shall reacquire the lost satellite signal and reestablish position location within 5 seconds after GPS signal has been reacquired. This requirement shall be verified during the DMT Functional Testing. The use of a stopwatch is required.

X

4.9.2 ACCURACY

Requirement: E A D T C DMT horizontal (in both dimensions) and vertical position accuracy shall be equal or better than 3 meters (3m) Root Mean Squared (RMS). This requirement shall be verified during the DMT Functional Testing utilizing a registered survey marking on the range. The DMT coordinates shall be within 3 meters of the mark. The test has to be run 10 times and the RMS calculated.

X

The DMT accuracy shall be maintained over the entire coverage area. This requirement shall be verified during the DMT Functional Testing to include all course roads, CGI village, and Dismounted Areas.

Version: 1.1

4.9.3 UPDATE AND REPORTING RATE

Position location reporting rates shall be controllable within the exercise scenario function based on elapsed time and distance traveled from last reported position. This requirement shall be verified during the DMT Coverage Testing.

X

The DMT shall provide elapsed time reporting rates, which are configurable from 5 to 180 seconds with 5-second increments. This requirement shall be verified during the DMT Coverage Testing.

X

The DMT shall provide distance traveled reporting rates from 5 meter (5m) to 10 meters (10m) with 1-meter (1m) increments. This requirement shall be verified during the DMT Coverage Testing.

X

4.10 SAFETY REQUIREMENTS

Requirement: E A D T C The DMT shall be safe to operate IAW DRTS Performance Specification PRF-PT-768.

X X

4.11 DMT ELECTROMAGNETIC COMPATIBILITY

Requirement: E A D T C The DMT shall be electromagnetically compatible with itself and adjacent electrical and electromechanical environment in fulfillment of Performance Specification PRF-PT-768. The DMT components shall be subjected to the following EMC tests. No equipment supplied shall be exempted from these requirements. DMT Equipment on the range shall not emit any intentional or unintentional signal that may cause live ammunition to be exploded. The signal strength shall not be greater than -80 decibels from the peak operating power of the transmitter fundamental frequency. Signal strength shall be measured at the antenna post and external housings when in a standby or receiving condition. DMT shall be tested to the requirements of MIL-STD-461F, Ground Army, CE101-102, CS101, CS114, CS116, RE102, and RS103.

For COTS products certification will suffice, otherwise for new products test results will be required.

X X

4.11.1 ELECTROMAGNETIC ENVIRONMENTAL EFFECTS (E3)

Requirement: E A D T C The DMT components shall be electromagnetically compatible among all subsystems and equipment found at

Version: 1.1 the training ranges and with electromagnetic environment external to the HW.

All equipment (NDI, COTS, modified COTS, new design) shall operate in the electromagnetic environment (EME) described below without being a source of electromagnetic interference or a victim of site/location generated electromagnetic emissions, whether radiated or conducted.

X

4.11.2 INTRA-SYSTEM EMC

Requirement: E A D T C The DMT shall be electromagnetically compatible with itself such that system operational performance requirements can be met.

X

4.11.3 INTER-SYSTEM EMC

Requirement: E A D T C The DMT shall be electromagnetically compatible with its defined EME such that the system operational performance requirements can be met.

X

4.11.4 NON-DEVELOPMENTAL ITEMS (NDI) AND COMMERCIAL ITEMS

Requirement: E A D T C NDI and commercial items shall be compliant with the E3 requirements to ensure that the system operational performance requirements are met.

X

4.11.5 LIFE CYCLE, E3 HARDNESS

Requirement: E A D T C The DMT operational performance and E3 requirements shall be applicable throughout the rated life cycle of the equipment.

X

The DMT shall detect degradation that would affect the safe E3 operations of the DMT at the installation.

X

4.11.6 ELECTROMAGNETIC RADIATION HAZARDS (EMRADHAZ)

Requirement: E A D T C The DMT shall be designed to ensure that personnel, fuels, and ordnance are protected from hazardous effects of electromagnetic radiation.

X

4.12 TRANSCEIVER/RECEIVER

The DMT shall provide near real-time data transmission. X

Version: 1.1

The DMT transmitter/receiver shall comply with frequency allocations and spectrum at the intended installation.

X

The DMT transmitter/receiver shall have a unique access identifier and automatically enter the communication network when the transceiver is on. This requirement shall be verified during the DMT Functional Testing.

X

4.13 DMT POWER OUTPUT

Requirement: E A D T C The DMT’s transmission power output shall not exceed 2 Watts RMS.

X X

The DMT’s transmission power shall not exceed safety thresholds for man-worn transceivers.

Version: 1.1

APPENDIX A: DRTS SYSTEM DIAGRAM

Version: 1.1

APPENDIX B: ACRONYM LIST

The following list of abbreviations and acronyms are utilized in the DRTS Dismounted Tracker Performance Specification.

ABBREVIATION TERM

BIT Built-In Test CCA Circuit Card Assembly COTS Commercial Off The Shelf CT Control Tower CTIA Common Training Instrumentation Architecture DMT Dismounted Tracker DRTS Digital Range Training System GPS Global Positioning System HW Hardware IAW In Accordance With ICD Interface Control Document LRU Line-Replaceable Unit PU Player Unit RMS Root Mean Squared SAW Situational Awareness Workstation SOT System Operational Test STT System Technical Test SW Software TOMC Test and Operation Maintenance Console TSPI Time-Space Position Information VHF Very High Frequency

1 Introduction
2 Applicable Documents
2.1 Military Specifications, Standards, and Handbooks
2.2 Other Government Documents
3 DMT Requirements
3.1 General Description
3.2 Dismounted Tracker (DMT) Requirements
3.3 DMT Built-In Test (BIT)
3.4 DMT Batteries
3.5 DMT Battery Charger
3.6 Accessibility
3.7 DMT PHYSICAL CHARACTERISTICS
3.7.1 WEIGHT
3.7.2 FINISH
3.7.3 ENVIRONMENTAL REQUIREMENTS
3.7.3.1 STORAGE
3.7.3.2 OPERATING TEMPERATURE
3.7.3.3 HUMIDITY
3.7.3.4 SEA COAST/SALT SPRAY
3.7.3.5 ARID/DESERT CONDITIONS
3.7.3.6 RAIN
3.7.3.7 SUBMERSION
3.7.3.8 SHOCK
3.7.3.9 VIBRATION
3.8 DMT Software (SW)
3.9 DMT Position Data
3.9.1 DMT GPS RECEIVER
3.9.2 ACCURACY
3.9.3 UPDATE AND REPORTING RATE
3.10 Safety Requirements
3.11 DMT ELECTROMAGNETIC COMPATIBILITY (EMC)
3.11.1 ELECTROMAGNETIC ENVIRONMENTAL EFFECTS (E3)
3.11.2 INTRA-SYSTEM EMC
3.11.3 INTER-SYSTEM EMC
3.11.4 NON-DEVELOPMENTAL ITEMS (NDI) AND COMMERCIAL ITEMS
3.11.5 LIFE CYCLE, E3 HARDNESS
3.11.6 ELECTROMAGNETIC RADIATION HAZARDS (EMRADHAZ)
3.12 Transmitter/Receiver
3.13 DMT Transmit Power Output
4 Verification
4.1 Acceptance Test Structure
4.2 DMT Requirements
4.3 DMT Built In Tests (BIT)
4.4 DMT Batteries
4.5 DMT Battery Charger
4.6 Accessibility
4.7 DMT PHYSICAL CHARACTERISTICS
4.7.1 WEIGHT
4.7.2 FINISH
4.7.3 ENVIROMENTAL REQUIREMENTS
4.7.3.1 STORAGE
4.7.3.2 OPERATING TEMPERATURE
4.7.3.3 HUMIDITY
4.7.3.4 SEA COAST/SALT SPRAY
4.7.3.5 ARID/DESERT CONDITIONS
4.7.3.6 RAIN
4.7.3.7 SUBMERSION
4.7.3.8 SHOCK
4.7.3.9 VIBRATION
4.8 DMT SW
4.9 DMT POSITION DATA
4.9.1 DMT GPS RECEIVER
4.9.2 ACCURACY
4.9.3 UPDATE AND REPORTING RATE
4.10 SAFETY REQUIREMENTS
4.11 DMT ELECTROMAGNETIC COMPATIBILITY
4.11.1 ELECTROMAGNETIC ENVIRONMENTAL EFFECTS (E3)
4.11.2 INTRA-SYSTEM EMC
4.11.3 INTER-SYSTEM EMC
4.11.4 NON-DEVELOPMENTAL ITEMS (NDI) AND COMMERCIAL ITEMS
4.11.5 LIFE CYCLE, E3 HARDNESS
4.11.6 ELECTROMAGNETIC RADIATION HAZARDS (EMRADHAZ)
4.12 TRANSCEIVER/RECEIVER
4.13 DMT POWER OUTPUT
Appendix A: DRTS System Diagram
Appendix B: Acronym List