Am_0004_drawings.pdf

PDF 1 MB Posted

Attached to
Police Academy Female Staff College, Kabul, Afghanistan
Solicitation number
W5J9JE-16-R-0049
Issued by

About this file

Amendment 0004 Drawings

View the file

Other files

File Type Posted
A22_W5J9JE-16-R-0049-0005.pdf PDF
Site_visit_sign_in_sheet_.pdf PDF
Am_0004_specs.pdf PDF
A22_W5J9JE-16-R-0049-0004.pdf PDF
A22_W5J9JE-16-R-0049-0003.pdf PDF
A22_W5J9JE-16-R-0049-0002.pdf PDF
A22_W5J9JE-16-R-0049-0001.pdf PDF
SPECS.pdf PDF
SUMMARY.pdf PDF
FAR.pdf PDF
16R0049.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET ID

X

Middle East District of Engineers

US Army Corps

U S A rm y C o rp s o f

E n g in e e rs

M id d le E a s t

D is tr ic t

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R

DIMENSIONS SHOWN ARE IN MILLIMETERS.

UNLESS OTHERWISE NOTED, LINEAR

A N

P -1

-0

P

O L

IC

E A

C A

D E

M Y P

H A

S E

R E

A C

H B

A C

K G

E N

D E

R P

R O J E

C T

K A

B U

L

A F

G H

A N

IS

T

N

:1

J B

P

J B

P R

L M

P ro je c t L e a d

B R

IA

N J

O H

N S

O N P .E

/2

/2

/2

/2

W J J E -1

-R -0

BOTTOM OF BEAM

ELEV. 15300

ROOF

ELEV. 16000

BOTTOM OF BEAM

ELEV. 12100

ELEV. 12800

BOTTOM OF BEAM

BOTTOM OF BEAM

BOTTOM OF BEAM

BOTTOM OF BEAM

ELEV. -3200

GROUND FLOOR

TOP OF FOUNDATION

BOTTOM OF FOUNDATION

2ND FLOOR

3RD FLOOR

4TH FLOOR

5TH FLOOR

ELEV. 0.0

ELEV. -700

ELEV. -4000

ELEV. 3200

ELEV. 2500

ELEV. 6400

ELEV. 5700

ELEV. 9600

ELEV. 5900

#22 VERT BARS

MAT FOUNDATION

#22 VERT BARS

S-806

SCALE = 1:50

S-803

BEAM TYP.

500 x 500 COLLECTOR

OPENING

1 0 4321

1:50

S H

E A

R W

A L L R

E B

A R E

L E

V A

T

IO

N

REINFORCEMENT NOT SHOWN FOR CLARITY

NOTE: BOUNDARY ELEMENT AND FOUNDATIONEAST/WEST ELEVATION VIEW OF SHEAR WALLS

OPENING

OPENING

OPENING

OPENING

OPENING

OPENING

OPENING

OPENING

OPENING

OPENING

OPENING

OPENING

OPENING

OPENING

O .C E .F

@ 250 O.C. E.F.

O .C E .F

O .C E .F

O .C E .F

O .C E .F

O .C E .F

@ 250 O.C. E.F.

S-806

T

Y P

R A

F

A S -8

.d g n

R E

V

IS

E D B

Y A

M E

N D

M E

N T

/2

/2

D .L .W

4 4

4 4

4 4

4 4

TYP

COLUMN

500 x 500

H

O R

Z

B A

R S

H

O R

Z

B A

R S

H

O R

Z

B A

R S

H

O R

Z

B A

R S

H

O R

Z

B A

R S

H

O R

Z

B A

R S

1000 9300 1000

24600

X

XXXX

EL. XX.XX

ROOM NAME

A

SHEET ID

X

Middle East District of Engineers

US Army Corps

U S A rm y C o rp s o f

E n g in e e rs

M id d le E a s t

D is tr ic t

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R

P -1

-0

P

O L

IC

E A

C A

D E

M Y P

H A

S E

R E

A C

H B

A C

K G

E N

D E

R P

R O J E

C T

K A

B U

L

A F

G H

A N

IS

T

/2

/2

B R

IA

N R J

O H

N S

O N P

E

P R

O J E

C T L

E A

D

D A

T E

R A

F

A

A -0

.d g n

L M J

:1

A-001

A R

C H

IT

E C

T U

R A

L G

E N

E R

A L N

O T

E S

L M J

A B

B R

E V

IA

T

IO

N S A

N D L

E G

E N

D

/2

/2

W J J E -1

-R -0

R E

V

IS

E D B

Y A

M E

N D

M E

N T

/2

/2

D .L .W

1.7

ARCHITECTURAL GENERAL NOTES: ABBREVIATIONS: LEGEND:

KEY NOTEX

WALL TYPE INDICATOR

WINDOW TYPE INDICATOR

DOOR AND HW. TYPE INDICATOR

COLUMN / GRID INDICATOR

ELEVATION DATUM (IN MILIMETERS)

ROOM IDENTIFIER

HOOK-MOUNTED FIRE EXTINGUISHER

ACM ABESTOS CONTAINING MATERIAL

ALUM. ALUMINUM

ARCH. ARCHITECTURAL

BHMA BUILDERS HARDWARE MANUFACTURERS ASSOCIATION

CMU CONCRETE MASONRY UNIT

COMM. COMMUNICATION

CONC. CONCRETE

DN DOWN

DS DOWNSPOUT(S)

DTL. DETAIL(S)

DWGS. DRAWINGS

EIFS EXTERIOR INSULATION FINISHING SYSTEM

EL. ELEVATION

ELEC. ELECTRICAL

EXT. EXTERIOR

FIN. FINISHED

GA. GAUGE

HGT. HEIGHT

HM. HOLLOW METAL

HRS. HOURS

HW. HARDWARE

J.C. JANITOR CLOSET

LAM. LAMINATED

MAT. MATERIAL

MAX. MAXIMUM

MECH. MECHANICAL

MIN. MINIMUM

MISC. MISCELLANEOUS

MM MILLIMETERS

M METERS

N.T.S. NOT TO SCALE

OPP. OPPOSITE

PN PERSON(S)

RM. ROOM

R.R. REST ROOM

SCH. SCHEDULED

STRUCT. STRUCTURAL

THRES. THRESHOLD

TYP. TYPICAL

VEST. VESTIBULE

w/ WITH

1. UNLESS OTHERWISE INDICATED, PLAN DIMENSIONS ARE TO OUTER EDGE OF

EXTERIOR STRUCTURAL COLUMNS, COLUMN GRID ON CENTERLINES, NOMINAL

SURFACE OF MASONRY, ROUGH OPENINGS OF DOORS AND WINDOWS, AND FACE

OF CONCRETE WALLS.

2. OPENINGS FOR DOORS AND FRAMES SHALL BE LOCATED 200 MM FROM

THE EDGE OF ADJACENT WALLS OR COLUMNS UNLESS NOTED

OTHERWISE.

3. FINISH FLOOR ELEVATIONS IS MEASURED FROM TOP OF SLAB TO TOP OF SLAB.

4. INTERIOR PARTITIONS SHALL BE 150 MM CMU, UNLESS OTHERWISE NOTED. EXTERIOR

PARTITIONS SHALL BE 200 MM CMU.

5. LINE OF EXISTING GRADES, AS SHOWN ON THE BUILDING ELEVATIONS AND

SECTIONS ARE APPROXIMATE.

6. VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THIS CONTRACT,

OR BY OTHERS.

7. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL AND OTHER

CATEGORIES OR DRAWINGS FOR ADDITIONAL NOTES.

8. VERIFY SIZE AND LOCATIONS OF, AND PROVIDE: REQUIRED OPENINGS THROUGH

FLOORS AND WALLS, ACCESS DOORS AND HATCHES, FURRING, CURBS, ANCHORS

AND INSERTS. PROVIDE ALL BASES AND BLOCKING REQUIRED FOR ACCESSORIES,

MECHANICAL, ELECTRICAL AND OTHER EQUIPMENT.

9. FILL REMAINING SPACE AT PENETRATIONS IN FIRE-RATED FLOORS, PARTITIONS,

AND CEILINGS WITH APPROPRIATE FIRESTOPPING MATERIAL.

10. FOR APPLICABLE CODES AND LIFE SAFETY PLANS SEE SHEETS A-002 THROUGH

A-003.

11. FOR DOOR AND HARDWARE INFORMATION SEE SHEET A-601.

12. FOR WINDOW SCHEDULE SEE SHEET A-603.

13. FOR INTERIOR FINISH SCHEDULE SEE SHEET A-602.

14. ALL PENETRATIONS AND OPENINGS THROUGH RATED ASSEMBLIES SHALL MEET WALL

AND FLOOR ASSEMBLY FIRE RATINGS.

15. PREPARE SURFACES TO BE COATED, REPAIR OR FILL MORTAR JOINTS, AND REPAIR

MINOR DEFECTS, INCLUDING BUT NOT LIMITED TO SPALLS, IN ACCORDANCE WITH

MANUFACTURER'S RECOMMENDATIONS.

16. CONCRETE AND MASONRY SURFACES SHALL BE ALLOWED TO CURE FOR AT LEAST

30 DAYS BEFORE COATING. CONCRETE SLABS-ON-GRADE SHALL BE ALLOWED TO

CURE 90 DAYS BEFORE STAINING OR SEALING.

17. ALL FLOOR FINISHES SHALL BE EPOXY SEALED CONCRETE, EXCEPT WHERE NOTED,

SEE SHEET A-602.

18. ALL CEILING AND WALL FINISHES SHALL BE COATED IN PRE-COLORED PLASTER

APPLIED TO STRUCTURE; EXCEPT WHERE NOTED.

19. DO NOT USE NAY ABESTOS CONTAINING MATERIALS (ACM) IN PROJECT. ACM IS DEFINED

AS 1% OR MORE BY VOLUME OR PAINT MATERIALS CONTAINING LEAD CONTENT IN

EXCESS OF 0.009% OF WEIGHT OF THE TOTAL NON-VOLATILE CONTENT OF PAINT OR

THE WEIGHT OF THE DRIED PAINT FILM, OR MERCURIAL FUNGICIDES.

20. ALL EXTERIOR WALL SHALL HAVE AN EXTERIOR FINISHING INSULATION SYSTEM (EIFS)

FINISH OVER CMU AND CONCRETE SUBSTRATES. PROVIDE CONTROL JOINTS IN EIFS

WALL FINISH AS REQUIRED.

21. FOR INTERIOR DESIGN AND FURNITURE INFORMATION SEE INTERIOR DRAWINGS.

22. CONTRACTOR SHALL PROVIDE SIGNAGE AS THROUGHOUT BUILDING AS REQUIRED.

23. CONTRACTOR TO PROVIDE "NOT AN EXIT" SIGNS ON ALL DOORS LEADING TO EQUIPMENT

ACCESS PLATFORMS ON SECOND THROUGH FIFTH FLOORS.

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

11 1 1

3 9

AAAAA

A AAA

AAAA

A-301

A-301

A-102

B

5 1

NN

0 10001000 4000 9000

SCALE = 1:100

A-201

A-201

A-201

A-401

105019001100

245014002450250010750

A-404

X

1 5

14250 14250 4650 4650 4650

120019001200 120019001200 120019001200 120019001200 120019001200 120019001200 120019001200 120019001200

2500 2000 2

0 15

9 9

A-405

C

A-201

SHEET ID

X

Middle East District of Engineers

US Army Corps

U S A rm y C o rp s o f

E n g in e e rs

M id d le E a s t

D is tr ic t

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R

P -1

-0

P

O L

IC

E A

C A

D E

M Y P

H A

S E

R E

A C

H B

A C

K G

E N

D E

R P

R O J E

C T

K A

B U

L

A F

G H

A N

IS

T

B R

IA

N R J

O H

N S

O N P

E

P R

O J E

C T L

E A

D

D A

T E

L M J

:1

A-102

F

IR

S T F

L O

O R P

L A

N

L M J

R A

F

A

A -1

.d g n

/2

/2

W J J E -1

-R -0

/2

/2

R E

V

IS

E D B

Y A

M E

N D

M E

N T

/2

/2

D .L .W

MECH./ELEC.

COMM. ROOM

DN

UP

DN

UP

VEST.

OFFICE

SECURITY OFFICE

J.C.

DINING ROOM

CORRIDOR

CLINICDIRECTOR

OFFICE

ADMINISTRATION OFFICE

CONFERENCE ROOM

MECH./ELEC.

COMM. ROOM

CHANGING

ROOM

REST ROOM

KITCHEN

OFFICE

STORAGE

R.R.

J.C.

CORRIDOR

STAIR 2STAIR 1

100 101

2.9

7.6

6.2

4.1

8.6

4.5

2.9

6.2

5.4 5.4 1.3

2.9

8.68.68.6

2.9

4.1

8.6

6.2

2.9

6.2

8.6

8.6

8.6

7.6

120019001200 170010001600 170010001600 120019001200

1.7

9.12

A C

T

IV

E

IN

A

C T

IV

E

10.14 10.7

9.12

8.6

110A

52800

45504800480048004800480048004800480048004550250

4050500

3750 5200 5500 8600 14250 4300 5200 3750

4650 9475 192254200

4050 120019001200

4650 4225

108756600764225005633

120019001200 120019001200 120019001200 4050

3.12

8.10

10.13

3.12

14.6

11.14

10.11

12.15

9.11

SCALE = 1:100

GROUND FLOOR PLAN

GENERAL NOTES: LEGEND:

PROPOSED NORTH

LINEAR DIMENSIONS SHOWN

ARE IN MILLIMETERS (MM),

UNLESS OTHERWISE NOTED

KEY NOTES:

WINDOW TYPE, SEE SHEET A-603

KEY NOTEX

WALL TYPE, SEE SHEET A-001

DOOR AND HW. TYPE, SEE SHEET A-601

A.UNLESS OTHERWISE INDICATED, PLAN DIMENSIONS ARE TO OUTER EDGE OF

EXTERIOR STRUCTURAL COLUMNS, COLUMN GRID ONCENTERLINES, NOMINAL

SURFACE OF MASONRY, ROUGH OPENINGS OF DOORS AND WINDOWS, AND FACE

OF CONCRETE WALLS.

B.OPENINGS FOR DOORS AND FRAMES SHALL BE LOCATED 200 MM FROM

THE EDGE OF ADJACENT WALLS OR COLUMNS UNLESS NOTED

OTHERWISE.

C.INTERIOR PARTITIONS SHALL BE 150 MM CMU, UNLESS OTHERWISE NOTED.

D.FILL REMAINING SPACE AT PENETRATIONS IN FIRE-RATED FLOORS,

PARTITIONS, AND CEILINGS WITH APPROPRIATE FIRESTOPPING

MATERIAL.

E.CONTRACTOR SHALL PROVIDE SIGNAGE THROUGHOUT BUILDING.

F.PROVIDE POLISHED STAINLESS MIRROR 600 x 900 ABOVE EVERY

SINK FAUCET.

1. SHOWER

2. WESTERN STYLE TOILET

3. SINK

4. EASTERN STYLE TOILET

5. ABLUTION

6. JANITOR SINK

7. 500 MM x 500 MM COLUMN - (SEE STRUCT. DWGS.)

8. NOT USED

9. DOUBLE SWING GATE - (SEE SHEET DETAIL 7/A-403)

10. CONC. SLAB w/ HEAT PUMP - (SEE STRUCT. AND MECH. DWGS.)

11. KITCHEN SINK/POT WASH

12. PROPANE STOVES - (SEE SHEET 4/A-404 AND MECH. DWGS.)

13. PROPANE TANK ENCLOSURE - (SEE STRUCT. AND MECH. DWGS.)

14. NOT USED

15. HOOK MOUNTED FIRE EXTINGUISHER

16. NOT USED

17. METAL AWNING /w CORRUGATED ROOF - (SEE SHEET A-201)

18. CONC. SIDEWALK - (SEE CIVIL DRAWINGS)

19. NOT USED

20. HORIZONTAL WINDOW BLINDS (TYP. AT EACH WINDOW)

21. NOT USED

A-404

A-402

22. METAL LOCKER

23. 1200 MM x 254 MM POLYMER BENCH

X

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

A A A A AAAAAA

AAAAAAAAAA

A A

A-201

A-301

A-201

A-201

A-301

A-201

A-103

A-401

10000

A-402

NN

0 10001000 4000 9000

SCALE = 1:100

1 1 1 1 1

11111

9 3 3 9

3 9

4 4

A-404

SHEET ID

X

Middle East District of Engineers

US Army Corps

U S A rm y C o rp s o f

E n g in e e rs

M id d le E a s t

D is tr ic t

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R

P -1

-0

P

O L

IC

E A

C A

D E

M Y P

H A

S E

R E

A C

H B

A C

K G

E N

D E

R P

R O J E

C T

K A

B U

L

A F

G H

A N

IS

T

L M J

:1

A-103

S E

C O

N D F

L O

O R P

L A

N

L M J

B R

IA

N R J

O H

N S

O N P

E

P R

O J E

C T L

E A

D

D A

T E

R A

F

A

A -1

.d g n

/2

/2

W J J E -1

-R -0

/2

/2

R E

V

IS

E D B

Y A

M E

N D

M E

N T

/2

/2

D .L .W

4 4

MECH./ELEC.

COMM. ROOM

201200

206 208 209 210

215213212211

CLASSROOM

(30 PN)

CLASSROOM

(30 PN)

CLASSROOM

(30 PN)

CLASSROOM

(30 PN)

CLASSROOM

(30 PN)

DN

UP

DN

UP

MECH./ELEC.

COMM. ROOM

J.C.

STAIR 2

J.C.

CHANGING

ROOM

CLASSROOM

(30 PN)

CLASSROOM

(30 PN)

CLASSROOM

(30 PN)

CLASSROOM

(30 PN)

CLASSROOM

(30 PN)

REST ROOM

CORRIDOR

REST ROOM

CHANGING

ROOM

STAIR 1

1.7

216 217

218 219

2.9

2.9

7.6

2.9

2.9

7.6

8.6 8.6 8.6 8.6 8.6

8.68.6

150010000

105019001100

110019001050

9.11

8.68.68.6

52800

45504800480048004800480048004800480048004550250

500 4050 120019001200

4050120019001200120019001200120019001200

422594509450

120019001200 120019001200

120019001200 120019001200

120019001200 120019001200

500 9025

120019001200

120019001200

120019001200 120019001200

120019001200 120019001200

120019001200 120019001200

3750 5200 5500 5500 5200 3750

15.6

15.6

15.6

15.6

9.12

9.129.12

10.13

9.12 9.12

9.129.12

9.11

9.12

10.13

GENERAL NOTES: LEGEND:

WINDOW TYPE, SEE SHEET A-603

KEY NOTEX

WALL TYPE, SEE SHEET A-001

DOOR AND HW. TYPE, SEE SHEET A-601

A.UNLESS OTHERWISE INDICATED, PLAN DIMENSIONS ARE TO OUTER EDGE OF

EXTERIOR STRUCTURAL COLUMNS, COLUMN GRID ONCENTERLINES, NOMINAL

SURFACE OF MASONRY, ROUGH OPENINGS OF DOORS AND WINDOWS, AND FACE

OF CONCRETE WALLS.

B.OPENINGS FOR DOORS AND FRAMES SHALL BE LOCATED 200 MM FROM

THE EDGE OF ADJACENT WALLS OR COLUMNS UNLESS NOTED

OTHERWISE.

C.INTERIOR PARTITIONS SHALL BE 150 MM CMU, UNLESS OTHERWISE NOTED.

D.FILL REMAINING SPACE AT PENETRATIONS IN FIRE-RATED FLOORS,

PARTITIONS, AND CEILINGS WITH APPROPRIATE FIRESTOPPING

MATERIAL.

E.CONTRACTOR SHALL PROVIDE SIGNAGE THROUGHOUT BUILDING.

F.PROVIDE POLISHED STAINLESS MIRROR 600 x 900 ABOVE EVERY

SINK FAUCET.

SCALE = 1:100

SECOND FLOOR PLAN

PROPOSED NORTH

LINEAR DIMENSIONS SHOWN

ARE IN MILLIMETERS (MM),

UNLESS OTHERWISE NOTED

KEY NOTES:

1. SHOWER

2. WESTERN STYLE TOILET

3. SINK

4. EASTERN STYLE TOILET

5. ABLUTION

6. JANITOR SINK

7. 500 MM x 500 MM COLUMN - (SEE STRUCT. DWGS.)

8. NOT USED

9. NOT USED

10. NOT USED

11. NOT USED

12. NOT USED

13. NOT USED

14. NOT USED

15. HOOK MOUNTED FIRE EXTINGUISHER

16. NOT USED

17. NOT USED

18. NOT USED

19. NOT USED

20. HORIZONTAL WINDOW BLINDS (TYP. AT EACH WINDOW)

21. HVAC EQUIPMENT ACCESS PLATFORM w/ SIDE-MOUNTED GUARD RAILING

22. METAL LOCKER

23. 1200 MM x 254 MM POLYMER BENCH

RAF1656_A_A-001
RAF1656_A_A-102
RAF1656_A_A-103
Updated S-803.pdf
RAF1656_A_S-803

File details come from the government source that posted it. Updated .