MEO_d1989.pdf

PDF 172 KB Posted

Attached to
Amendment 0002 Federal contract opportunity
Solicitation number
W58RGZ-17-R-0100
Issued by
Department of the Army Materiel Command Aviation and Missile Life Cycle Management Command

About this file

MEO D1989

View the file

Other files for this federal contract opportunity

Other files attached to Amendment 0002, newest first.
File Type Posted
W58RGZ17R0100-0002.pdf PDF
MEO_d2172.pdf PDF
MEO_d2053.pdf PDF
MEO_d1988.pdf PDF
MEO_d1986.pdf PDF
W58RGZ17R0100.pdf PDF
DMWR_55-4320-278.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MAINTENANCE ENGINEERING ORDER

(AMCOM Reg. 750-2)

MEO NO.

DATE PAGE 1 of

TITLE Tolerances Unless otherwise noted, dimensions are in inches and tolerances are:

Fractional ………………… ± 1/32 Decimal ………………... ± 0.010 Angular ………………… ± ½°

APPLICABILITY CSI Critical Characteristic Affected?

Impact Statement Attached?

REFERENCES FOR RDECOM USE ONLY

DOCUMENT(S) AFFECTED

PURPOSE OR PROBLEM

PROJECT ENGINEER ENGINEERING REVIEW ENGINEERING RELEASE

MED FORM 5-DEC-09 1401-R-E

D 1989 Apr 19, 2017 3

IUID Parts Marking for (Misc) Warning Summary, Appendix A and C, Variable Displacement Axial Piston Pump Assembly, P/Ns PV3-075-20 (145HS100-3) and PV3-075-20A (145HS100-5)

Technical

INTERIM USE OF THIS MEO IS AUTHORIZED

UNTIL AFFECTED DOCUMENT IS UPDATED.

MEO CHANGE TYPE

4) Normal - Can be implemented with normal priorityPRIORITY IMPLEMENTATION CATEGORY

CH47 DAA

DMWR 55-4320-278 dated 15 April 2016 TN 165683 8/29/2016

DOCUMENT CHANGE IS REQUIRED Verification: Hands-On Table-Top None

Changes based on IUID MEO review (TN 165347). Implement MEOs D1986, D1988 and D1989 concurrently.

CASTILLO.NO

EL.1089736990

Digitally signed by

CASTILLO.NOEL.1089736990

DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=CASTILLO.NOEL.1089736990 Date: 2016.09.01 10:24:36 -05'00'

NOLEN.OTIS.

F.1231157146

Digitally signed by

NOLEN.OTIS.F.1231157146

DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=CONTRACTOR, cn=NOLEN.OTIS.F.1231157146 Date: 2016.09.01 06:47:47 -05'00'

Otis Nolen (Camber Corporation)

PETER.ROBERT.

ARTHUR.JR.108

7823942

Digitally signed by

PETER.ROBERT.ARTHUR.JR.1087823942

DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=PETER.ROBERT.ARTHUR.JR.108782394 Date: 2016.09.20 10:35:57 -05'00'

Noel Castillo Robert A. Peter, Jr.

PUBLICATION CHANGE REQUEST: REQUEST THAT THE FOLLOWING DATA BE INCLUDED IN THE NEXT

CHANGE OR REVISION TO THE PUBLICATION IDENTIFIED ABOVE.

WP NO. PAGE

NO.

PARA-

GRAPH

FIGURE/

TABLE

NO.

CHANGES

(EXACT WORDING OF CHANGES MUST BE GIVEN)

Warning Summar y

Appx A

ADD Warnings found on page 3 of this MEO.

REPLACE Reference DODI 5000.64 to read:

“ISO/IEC 15415 Information Technology - Automatic Identification and Data Capture Techniques - Bar Code Print Quality Test Specification - Two Dimensional Symbols”

Distribution Statement D:- Distribution authorized to Department of Defense and U.S. DoD contractors only to protect critical technology effective as of 26 June 2014. Other requests for this document must be referred to U.S. Army Aviation and Missile Research, Development and Engineering Center, ATTN: RDMR -AEM , Corpus Christi, TX 78419-5211

MED FORM 24 FEB 2016

Continuation Sheet

MEO NO.

PAGE of

WP NO. PAGE

NO.

PARA-

GRAPH

FIGURE/

TABLE

NO.

CHANGES

(EXACT WORDING OF CHANGES MUST BE GIVEN)

MED FORM 15-DEC-09 1401-R-E

Appx A (Cont)

Appx C

REPLACE Reference:

“GUIDE DEPARTMENT OF DEFENSE GUIDE TO UNIQUELY

IDENTIFYING ITEMS” to read:

“DOD GUIDE DEPARTMENT OF DEFENSE GUIDE TO UNIQUELY

IDENTIFYING ITEMS”

REPLACE Reference:

“GUIDE GUIDELINES FOR REGISTERING GOVERNMENT

SERIALIZATION, TYPE DESIGNATION AND OWNERSHIP OF MAJOR

END ITEMS, ASSEMBLIES AND SUBASSEMBLIES AND CAPITAL

EQUIPMENT” to read:

“DOD GUIDE DEPARTMENT OF DEFENCE GUIDE GUIDELINES

FOR REGISTERING GOVERNMENT SERIALIZATION, TYPE

DESIGNATION AND OWNERSHIP OF MAJOR END ITEMS,

ASSEMBLIES AND SUBASSEMBLIES AND CAPITAL EQUIPMENT”

REPLACE WEBSITES/Addressed to read:

“DPAP UID: DEFENSE PROCUREMENT AND ACQUISITION POLICY

http://www.acq.osd.mil/dpap/pdi/uid/data_submission_information.html

WAWF: WIDE AREA WORK FLOW E-BUSINESS SUITE

https://wawf.eb.mil/

TAMMS-A/MCDS: THE ARMY MAINTENANCE MANAGEMENT

SYSTEM – AVIATION/MAINTENANCE CONSOLIDATED DATABASE

SYSTEM

https://tamms-a.redstone.army.mil”

REPLACE Item Number 31 to read:

"Item Number: 31 National Stock Number: 8020-01-129-1143 Description: 1 IN. POLY-BRUSH, Foam (49AB6), JEN MFG Inc., or equivalent

U/M: BX”

MED FORM 24 FEB 2016

D 1989

Continuation Sheet

MEO NO.

PAGE of

MED FORM 15-DEC-09 1401-R-E

x

ISOPROPYL ALCOHOL, TT-I-735

ISOPROPYL ALCOHOL, TT-I-735. Isopropyl alcohol is flammable and toxic to eyes, skin, and respiratory tract. Wear protective gloves and goggles/face shield. Avoid repeated or prolonged contact. Use only in well ventilated areas (or use approved respirator as determined by local safety/industrial hygiene personnel). Keep away from open flames, sparks, or other sources of ignition.

ADHESIVE, EC2216 OR EA9394

Adhesive is toxic. It can irritate skin and cause burns. Avoid contact with skin, eyes, and clothing. In case of contact, immediately flush skin or eyes with water for at least 15 minutes. Get medical attention for eyes.

ADHESIVE, MMM-A-1617

Adhesive is combustible, reactive with strong oxidizers, and toxic to eyes, skin, and respiratory tract. Wear protective gloves and goggles/face shield. Avoid repeated or prolonged contact. Use only in well-ventilated areas or use approved respirator as determined by local safety/industrial hygiene personnel. Keep away from open flames or other sources of ignition.

DEGREASING SOLVENT, MIL-PRF-680, TYPE II

Degreasing Solvent is combustible and toxic to eyes, skin, and respiratory tract. Wear protective gloves and goggles/face shield. Avoid repeated or prolonged contact. Use only in well-ventilated areas or use approved respirator as determined by local safety/industrial hygiene personnel. Keep away from open flames or other sources of ignition.

LACQUER, MIL-PRF-81352

Lacquer is combustible, reactive with strong oxidizers, and toxic to eyes, skin, and respiratory tract. Wear protective gloves and goggles/face shield. Avoid repeated or prolonged contact. Use only in well-ventilated areas or use approved respirator as determined by local safety/industrial hygiene personnel. Keep away from open flame or other sources of ignition.

MED FORM 24 FEB 2016

D 1989

File details come from the government source that posted it. Updated .