GVPM - Mechanical
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
U.S. ARMY – DEVCOM – GROUND VEHICLE SYSTEMS CENTER
GROUND VEHICLE POWER & MOBILITY
6501 E. 11 Mile Road Building 212 and 212B Detroit Arsenal, MI 48397
| perform the following types of tests on Diesel Engines, Turbine Engines, Customer Specific Engines, and Military and Commercial Vehicles and components, High-Power Traction Motors, Inline Generators, Inverters, DC-DC Converters, Alternators, Hybrid Electric Technology Components, Heat Exchangers, Radiators | ||
| Mechanical Scope Expires: 1/31/2024 | ||
| ECL, PEVEL Laboratory, Propulsion Laboratory | ||
| Technology | Range | Test Method |
| Engine / Engine Component, Full Vehicle / Vehicle Component Dynamometer Testing | Torque (1 to 7 400) lb-ft Engine/Transmission Component (1 to 14 300) lb-ft Each Wheel |
(1 to 60 000) lb-ft Each Track
| (1 to 70 000) lb-ft Axle | LQP-13-WI01, LQP-13-WI02, LQP-13-WI03, LQP-13-WI04, LQP-13-WI08, LQP-13-WI09, LQP-13-WI12, LQP-20-WI17, LQP-20-WI18, LQP-20-WI19, LQP-20-WI23, Customer Specific, Military and Commercial Vehicl | |
| Rotational Speed |
(0 to 200 000) RPM Power Up to 1 600 HP Pressure (-5 to 6 000) Psig Liquid Flow (1 to 250) GPM Liquid Flow – Mass (1 to 1 000) lbs/hr Air Flow (125 to 10 100) ACFM Temperature (-90 to 2 000) °F Humidity (10 to 90) %RH Temperature (Environmental) (-90 to 175) °C Solar Load To 1 200 W/m2
| Calorimeter Laboratory | |||
| Technology | Range | Test Method | |
| Heat Exchanger, Radiator Calorimeter Testing | Liquid Flow | ||
| (0 to 300) GPM | LQP-20-WI34, LQP-20-WI36, LQP-20-WI37, LQP-20-WI38, SAE J1994 Method 5.1, Customer Specific, Military | ||
| Temperature |
(60 to 200) °C Pressure (0 to 200) Psig (0 to 20) Psia Volumetric Flow
50 000 SCFM
Mass Flow
3.75 lb/min Humidity (10 to 80) %RH
GVPM - Electrical
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
U.S. ARMY – DEVCOM – GROUND VEHICLE SYSTEMS CENTER
GROUND VEHICLE POWER & MOBILITY
6501 E. 11 Mile Road Building 212 and 212B Detroit Arsenal, MI 48397
| Perform the following types of tests on Battery Cells, Modules, Packs, Ultra-Capacitors, Automotive and Heavy-Duty Electrical Components and Systems, High-Power Traction Motors, Inline Generators, Inverters, DC-DC Converters, Alternators, Hybrid Electric Technology Components | ||
| Electrical Scope Expires: 1/31/2024 | ||
| ESL Laboratory | ||
| Technology | Range | Test Method |
| Energy Storage Devices |
Extreme Temperature High Temperature Cycling High Temperature Discharge Cycles Full Charge Capacity Reserve Capacity Low Temperature Capacity Deep Cycle Capacity Retention of Charge Life-Cycle Capacity Deep Discharge Recovery Shelf Life Test Cranking Amps Deep Cycle Life High Temperature Deep Cycle Life Battery Storage Life Charging DC Current (± 2 000) Amps DC IL-PRF-32143C Sections:
3.4.1, 3.4.2, 3.6.1.1, 3.6.1.2, 3.6.1.3, 3.6.1.4, 3.6.2, 3.6.4, 3.6.5, 3.6.7, 4.2.6.1, 4.2.6.2, 4.2.6.3, 4.4.1, 4.4.2, 4.6.1.1, 4.6.1.2, 4.6.1.3, 4.6.1.4, 4.6.2, 4.6.4 MIL-PRF-32565C Sections:
3.5.4, 3.5.5, 3.5.6, 3.5.7, 3.5.8, 3.5.9, 3.5.11, 4.4.6.1, 4.4.6.2, 4.4.6.3, 4.4.6.4, 4.4.6.5, 4.4.7, 4.4.9, 4.4.9.1, 4.4.9.2
LQP-20-WI01
LQP-20-WI02
LQP-20-WI03
LQP-20-WI06
LQP-20-WI07
LQP-20-WI08
LQP-20-WI09
LQP-20-WI13
LQP-20-WI14
LQP-20-WI16
Customer Specific, Military
| C Voltage (Up to 600) Volts DC |
| Temperature (Environmental) |
(-65 to 150) °C Temperature (Measure) (-35 to 195) °C
| Impedance (0.001 to 1 000) Ω |
| Battery Weight (Up to 400) lbs |
| ECL, Pevel Laboratory, Propulsion Laboratory | ||
| Technology | Range | Test Method |
| Engine, Engine Components |
Vehicle Support Testing High Voltage Component High Temperature Efficiency Power Quality Transient Voltage Ripple Characterization DC Voltage Generate (0 to 900) VDC Measure (0 to 1300) VDC LQP-13-WI13
LQP-20-WI15
LQP-20-WI17
LQP-20-WI18
LQP-20-WI19
LQP-20-WI21
LQP-20-WI23
MIL-PRF-GSC600A
sec.: 3.1.3
MIL-STD-704F
sec.: 5.3.2, 5.3.3, 5.4.3
MIL-STD-1275D
sec.: 5.1.1 Customer Specific., Military AC Voltage Generate (0 to 1000) VAC Measure (0 to 1000) VAC DC Current Generate (0 to 1200) ADC Measure (0 to 1500) ADC AC Current Measure (0 to 1200) AAC Resistance Generate (0 to 10) KΩ Measure (0 to 1) GΩ Frequency Generate 1 µHz to 50 MHz Measure 0.01 Hz to 2 MHz
| Power Absorption / Supplies | ||
| (0 to 250) kW | MIL-STD-461G |
Sec.: CS101
LQP-13-WI09
Customer Specific., Military Impedance
0.001 Ω to 100 KΩ
DTL
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
U.S. ARMY – DEVCOM GROUND VEHICLE SYSTEMS CENTER
DURABILITY TEST LABORATORY
6501 E 11 Mile Road Building 215, MS 157 Detroit Arsenal, MI 48397
| Perform the following types of tests on Vehicle Systems, Subsystems, and Components: | ||
| Mechanical Scope Expires: 1/31/2024 | ||
| Technology | Range | Test Method |
| Vehicle Inertial Properties Characterizatio | Inertia for Pitch, Roll, and Yaw based on: |
Vehicle Weight: 3,000 - 100,000 lbf Track Width: Up to 110 in Distance from Front or Rear Axle to:
Longitudinal Center of Gravity: Up to 247 in
| Center of Gravity Height: Up to 60 in | ehicle Inertia Parameter Evaluation Rig (VIPER) II Operators Manual | |
| Suspension Component Characterization | Displacement: Up to 14 in |
Force: Up to 40,000 lbf Velocity: Up to 240 in/s
| Acceleration: Up to 100 g | Customer Specific | |
| Vibration (Single Axis) | Vertical Force: Up to 55,000 lbf |
Displacement: Up to 20 in Frequency: Up to 5,000 Hz Velocity: Up to 200 in/s Acceleration: Up to 320 g
| Environment: -60 to 160°F / 5% to 95% RH | MIL-STD-810 - Method 514 Procedure 1 - Method 516 - Method 525 Procedure 1 - Method 527 | |
| Vibration (Multi Axis) | Payload: Up to 1,100 lbf |
Displacement: ±1 in Angular Displacement: ±4 ° Frequency: Up to 500 Hz Velocity: Vertical 31 in/s, Lateral 23 in/s, Longitudinal 23 in/s Acceleration: Vertical 20 G, Lateral 12 G, Longitudinal 14 G
| Environment: -60 to 160°F | MIL-STD-810 - Method 514 Procedure 1 - Method 525 Procedure 1 - Method 527 Procedure 1 | ||
| Ancillary Measurements | Temperature Measurement: -454 to 700°F Displacement Measurement: Up to 30 in Acceleration Measurement: Up to 400 G Force Measurement: Up to 50,000 lbf | LQP-14-WI01 |
BTL
SCOPE OF ACCREDITION TO ISO/IEC 17025:2017
U.S. ARMY - DEVCOM - GROUND VEHICLE SYSTEMS CENTER
BRIDGE TECHNOLOGY LABORATORY
44090 Schilling Street Building 1424 Harrison Township, MI 48045
| Perform the following types of tests on Bridges and Gap Crossing Equipment: | ||
| Mechanical Scope Expires: 1/31/2024 | ||
| Technology | Range | Test Method |
| Structural Strength Test |
| Durability Test | Load (Up to 1 000 000) lbf | ||
| Displacement Up to 50 in | Trilateral Design and Test Code for Military Bridging and Gap-Crossing Section 8.5; LQTM-18-01 LQTM-18-02 | ||
| Dimensional Scope Expires: 1/31/2024 | |||
| Technology | Range | Test Method | |
| Outside Diameter 3 | Up to 6 in | LQP-18-WI06 | |
| Inside Diameter 3 | (0.7 to 6) in | LQP-18-WI06 | |
| 3 This test is not equivalent to that of a calibration. |
OPL
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
U.S. ARMY – DEVCOM - GROUND VEHICLE SYSTEMS CENTER
OCCUPANT PROTECTION LABORATORY
44030 Schilling Street, Building 1426 Harrison Township, MI 48045 Bldg 1426 (SANGB) Harrison Township, MI 48045
| Performs the following types of tests on Military Vehicle Sub-Systems, Components, and Interior Components: | ||
| Mechanical Scope Expires: 1/31/2024 | ||
| Technology | Range | Test Method |
| Head Impact | FMVSS 201U (Modified)1 |
LQP-25-01
| Sub-System Drop Tower (SSDT) | Acceleration Measurement: Up to 1000 g0 | LQP-25-02 Customer Specific2 |
| 1 Deviation on impact locations. | ||
| 2 This laboratory is also accredited to perform testing using customer specific requirements/methods |
FLL
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
U.S. ARMY – DEVCOM GROUND VEHICLE SYSTEMS CENTER
FUELS AND LUBRICANTS LABORATORY
6501 E. 11 Mile Road Building 210 Detroit Arsenal, MI 48397 Performs the following types of tests on Jet Fuel, Diesel Fuel, Engine Oil, Lubrication Oil, and Hydraulic Fluid:
| Mechanical Scope Expires: 1/31/2024 | |
| Test | Test Method |
| Flash Point (Automatic) | ASTM D93 |
| Distillation | ASTM D86, |
| Copper Strip Corrosion | ASTM D130 |
| Viscosity (Automatic) | ASTM D445, D7042 |
| Titration | ASTM D664 (TAN), D3242 (TAN), D4739 (TBN) |
| Calculated Cetane Index | ASTM D976, D4737 |
| Density | ASTM D1298, D4052 |
| Hydrocarbon Types | ASTM D1319 |
| Smoke Point | ASTM D1322 |
| Viscosity Index | ASTM D2270 |
| Sulfur, Total | ASTM D2622 |
| Fuel Electrical Conductivity | ASTM D2624 |
| Net Heat of Combustion | ASTM D3338/D3338M |
| Hydrogen Content | ASTM D3343 |
| Water Separation Index | ASTM D3948, D7224 |
| Lubricity | ASTM D5001 (BOCLE), D6079 (HFRR) |
| Fuel System Icing Inhibitor | ASTM D5006 |
| Elemental Analysis by ICP (Ag, Al, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, Pb, Sn, Ti, V, Zn, P, B, Si) | ASTM D5185 |
| Freeze Point | ASTM D7153 |
| Color | ASTM D6045 |
| Water Content | ASTM D6304 (Procedure C) |
| Derived Cetane Number | ASTM D6890, D7668 |
| Soot Content | ASTM D7686 |
SABL
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
U.S. ARMY – DEVCOM – GROUND VEHICLE SYSTEMS CENTER
SURVIVABILITY ARMOR BALLISTICS LABORATORY
6501 E. 11 Mile Road Building 219, MS 263 Detroit Arsenal, MI 48397
| Performs the following types of tests on Transparent Armor | |
| Mechanical Scope Expires: 1/31/2024 | |
| Test | Test Method |
| Ballistic Qualification | ATPD 2352 Section 4.5 |
APL
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
U.S. ARMY –DEVCOM - GROUND VEHICLE SYSTEMS CENTER
ARMY PETROLEUM LABORATORY
5085 U Ave., Bldg 85 New Cumberland, PA 17070-5083 Performs the following types of tests on jet fuel, lubricating oil, hydraulic fluid, greases, and antifreeze:
| Mechanical Scope Expires: 1/31/2024 | |
| Test | Test Method |
| Flash Point | ASTM D56 (Automated); ASTM D92 (Automated) |
| Fire Point | ASTM D92 |
| Distillation | ASTM D86; ASTM D1078 |
| Copper Strip Corrosion | ASTM D130; ASTM D4048 |
| Ash Content | ASTM D482; ASTM D874; ASTM D1119 |
| Titration | ASTM D664; ASTM D3242 |
| Calculated Cetane Index | ASTM D976; ASTM D4737 |
| Density | ASTM D1298; ASTM D4052; ASTM D5931 |
| Sulfur, Total | ASTM D5453 |
| Fuel Electrical Conductivity | ASTM D2624 |
| Fuel System Icing Inhibitor | ASTM D5006 |
| Particulate Matter | ASTM D5452; ASTM D6217 |
| Pour Point | ASTM D5949 |
| Freeze Point | ASTM D7153 |
| Color | ASTM D1500; ASTM D6045 |
| Water Content | ASTM D6304 (Procedure A) |
| Penetration/Stability | ASTM D217; ASTM D1403 |
| Rust Prevention | ASTM D1743; ASTM D1748 |
| Evaporation Loss | ASTM D972; ASTM D2595; ASTM D5800 (Procedure B) |
| pH | ASTM D1287; ASTM D6423 |
| Water Resistance | ASTM D1264 |
| Oil Separation | ASTM D1742; ASTM D6184 |
| Foam Test | ASTM D892 |
| Corrosion and Oxidation Stability | ASTM D4636 (Procedure 2); FTM 5308 |
| Gum | IP 540 |
| Dropping Point | ASTM D566; ASTM D2265 |
MCL
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
U.S. ARMY – DEVCOM GROUND VEHICLE SYSTEMS CENTER
MATERIAL CHARACTERIZATION LABORATORY
6501 E. 11 Mile Road Building 200A, MS 267 Detroit Arsenal, MI 48397
| Performs the following types of tests on Metallic Materials and Elastomeric Material: | |||
| Mechanical Scope Expires: 12/31/2022 | |||
| Technology | Range | Test Method | |
| Rockwell Hardness | Scales: A, B, C, 30N, 45N | ASTM E18 | |
| Brinell Hardness | 10/500, 10/1000, 10/1500, 10/3000 | ASTM E10 | |
| Microindentation Hardness | 25 g, 50 g, 100 g, 200 g, 300 g, 500 g, 1000 g | ASTM E38 | |
| Vickers, Knoop Hardness | 25 g, 50 g, 100 g, 200 g, 300 g, 500 g, 1000 g, 2000 g | ASTM E92 | |
| Notched Bar Impact | 406 J | ||
| -80 °C | ASTM E23 | ||
| Tension Test | 0.2 to 150 kN force 15 – 130 mm gage length | ASTM E8/E8M ASTM B557 | |
| Durometer Hardness | Type A | ASTM D2240 | |
| Tension Test | Test Method A |
Up to 1kN Force
| 23°C to 150°C | ASTM D412 | |
| Tension Test | Dumb-bell Type Specimens |
Up to 1 kN Force
| 23 °C to 150°C | ISO 37 | ||
| Tear Test | Up to 1 kN Force | ||
| 23 °C to 150°C | ASTM D62 | ||
| Abrasion Resistance | Rotary Drum Abrader | ASTM D5963 | |
| Density Specific Gravity | ASTM D297 (Sec. 16.3) ASTM D792 |
VEA
SCOPE OF ACCREDITATION TO ISO/IEC 17020:2017
U.S. ARMY – CCDC GROUND VEHICLE SYSTEMS CENTER
VEHICLE ELECTRONICS AND ARCHITECTURE
EMC LABORATORY
6501 E. 11 Mile Road Bldg. 200C MS-224 Detroit Arsenal, Michigan 48397-5000 Performs the following electromagnetic compatibility and electrical tests on electronic equipment and subsystems
| Electrical Scope Expires: 3/31/2023 | |
| Test | Test Method |
| Electromagnetic Compatibility | |
| Emissions Conducted | MIL-STD-461F/G: CE102 |
| Emissions, Radiated | MILL-STD-461F/G: RE102 (2 MHz to 18 GHz) |
| Conducted Susceptibility Power Leads Personnel Borne Electrostatic Discharge (ESD) | MIL-STD-461F/G: CS101 (30 Hz to 150 kHz) |
MIL-STD-461G: CS118 (±500 V to ±30 KV)