Attachment 0004 SURAC Test Evaluation Master Plan – Amendment 0006, 25 July 2016
Product Lead Land Mobile Radio
(PL LMR)
Subscriber Unit Radio and Accessory Contract
(SURAC)
Test Evaluation Master Plan
25 July 2016
Change Log
Date Change
25 July 2016 Updated language in paragraph 9.1 and first bullet of paragraph 11.1.
Table of Contents
Executive Summary
1 Purpose
2 Background
3 Scope and Objective
4 Test Case Scenarios and Locations
Table 1 System Version Under Test
5 SURAC Equipment and Test Categories
Table 2 - First Responder (FR) Portable Subscriber Unit Tests
Table 3 - Non-First Responder (NFR) Portable Subscriber Unit Test
Table 4 - First Responder (FR) Mobile Subscriber Unit Test
Table 5 - Non-First Responder (NFR) Mobile Subscriber Unit Test
Table 6 - First Responder (FR) Desktop Subscriber Unit Test
Table 7 - Non-First Responder (NFR) Desktop Subscriber Unit Test
6 Government Assumptions
7 Offeror Required Test Equipment
8 Test Team Composition
9 APL Technical Acceptance
9.1 Step 1 – Identification of System Version, Radio Type, and OEM – Go/No Go
9.2 Test Scenario, Case and Script Development and Execution
9.3 Step 2 - Pre-Test Programming Platform Validation Procedures – Go/No Go
9.4 Subscriber Unit Test Date and Test Plan
9.5 Step 3 - Test Set-Up – Go/No Go
9.6 Step 4 - Interoperability Test Execution
10 Government Responsibilities
10.1 Government Pre-Test Responsibilities
10.2 Government Test Responsibilities
11 Offeror Responsibilities
11.1 Offeror Pre-Test Responsibilities
11.2 Offeror Test Responsibilities
12 Test Conduct
12.1 Test Documentation
12.2 Test Report
13 New Equipment Offerings and System Testing
Appendix A – Requirements Statement RADIO TYPE TABLES
Appendix A – Table 1 First Responder Portable
Appendix A – Table 2 Non First Responder Portables
Appendix A – Table 3 First Responder Mobile
Appendix A – Table 4 Non-First Responder Mobile
Appendix A – Table 5 First Responder Desktop
Appendix A – Table 6 Non First Responder Desktop
Appendix B – Radio Type and Test Correlation Tables
Appendix B – Table 1 First Responder Portable Correlation Table
Appendix B - Table 2 Non First Responder Portable Correlation
Appendix B – Table 3 First Responder Mobile Correlation
Appendix B – Table 4 Non First Responder Mobile Correlation
Appendix B – Table 5 First Responder Desktop Correlation
Appendix B – Table 6 Non First Responder Desktop Correlation
Appendix C – Sample Test Form
ATTACHMENTS A through E
List of Tables
Table 1 System Version Under Test
Table 2 - First Responder (FR) Portable Subscriber Unit Tests
Table 3 - Non-First Responder (NFR) Portable Subscriber Unit Test
Table 4 - First Responder (FR) Mobile Subscriber Unit Test
Table 5 - Non-First Responder (NFR) Mobile Subscriber Unit Test
Table 6 - First Responder (FR) Desktop Subscriber Unit Test
Table 7 - Non-First Responder (NFR) Desktop Subscriber Unit Test
SURAC TEMP Page 1
Executive Summary
The Subscriber Unit Radio and Accessory Contract (SURAC) Interoperability Test and
Evaluation Master Plan (TEMP) will serve as the overarching vehicle to qualify Offerors technically acceptable and approved Association of Public-safety Communications Officials
(APCO) Project (P25) standard radios for entry onto the Army Land Mobile Radio (LMR)
Approved Products List (APL). Offerors seeking to add radios to Army LMR APL will be required to test each radio type they plan to market for inclusion onto the Army LMR APL to prove radios are 100 percent interoperable with Harris system versions (6.2.1, 9, 10x) and
Motorola system versions (7.5, 7.7, 7.8, 7.11, 7.13, 7.14, 7.15). The SURAC Interoperability
TEMP identifies test case scenarios and test locations (current and past APCO P25 upgraded
Installations) where testing will occur under Government observation.
Offeror APCO P25 compliant radios shall have the ability to operate on LMR narrowband trunked communication systems, providing support for first responder (FR), base support personnel and interoperability capability for Mutual Aid supporters. Offeror proposed radios shall be new and not refurbished and have the capability to support LMR software based infrastructure in accordance with SURAC Requirements Statement.
SURAC TEMP Page 2
1 Purpose This plan describes interoperability testing in order to develop an Army LMR APL for the
SURAC. The plan contains APCO P25 and non-APCO P25 test case scenarios. Offeror subscriber units shall be tested by the Offeror on selected government test bed locations to determine technical compliance and acceptance to decrease risk and costs to Offerors not able to meet the requirements. Subscriber units must pass ALL applicable test criterion to be placed on the Army LMR APL.
2 Background LMR Subscriber units are currently procured as part of an overall system concept, with services that include project management, systems engineering, site preparation, equipment installation optimization, security implementation and acceptance testing. The SURAC program will provide a contract vehicle to purchase additional subscribers to bring subscriber unit inventories up to the levels commensurate with mission requirements.
3 Scope and Objective The SURAC contract will serve as a vehicle to make technically qualified/approved LMR subscriber unit products and services available to government agencies to support legacy and new LMR systems. Subscriber Unit (SU) products include portable, mobile and desktop subscriber units, and accessories. Subscriber units shall be capable of supporting United States and Possessions (US&P) DoD, federal, and non-federal LMR spectral allocations and channel plans in UHF, VHF or 700/800MHZ or a combination thereof. Test locations will consist of
Army Installations identified in Table 1 that have undergone P25 and narrowband upgrades.
The scope of this test plan is to test the functionality of Offeror’s P25 and non-P25 compliant subscriber unit features and functions using the system versions defined in Table 1 to demonstrate required level of interoperability. Testing shall demonstrate interoperability exists between current systems and offered subscriber units. Interoperability testing demonstrates the
Offeror’s ability to provide subscriber units compliant with all requirements identified in the
SURAC Requirements Statement. Proposed subscriber equipment shall meet all requirements identified within the SURAC Requirements Statement and pass test criterion to be deemed technically acceptable.
The form, fit and function of the equipment version may be technically equal between some SU radio versions. In order to decrease Offerors expense of testing all equipment, the offers will be given the opportunity to attest to the form, fit and function compatibility of versions that are technically compatible.
4 Test Case Scenarios and Locations The Army currently has nine (9) LMR system versions in operation worldwide with varying features and functions. To test interoperability in this environment, the test cases are organized in a series of test cases grouped in five categories: general, telephone interconnect, OTAR, SURAC TEMP Page 3
OTAP and AES1. Offerors shall develop detailed test scripts matching their proposed equipment to prove interoperability. PL LMR has tentatively identified test bed locations for each system version to be utilized to complete interoperability testing. Where possible, two locations have been identified; however, only one installation will be chosen for testing a particular system version. Table 1 identifies the current LMR system versions and locations designated for subscriber unit interoperability testing. This table may be updated as systems are upgraded and are provided here for guidance. The Army intends to pilot the demonstration/interoperability testing at Ft Belvoir, VA for two weeks, followed by a week for retrospective actions. This pilot demonstration/interoperability testing will be the official test for Harris System version 10X.
The remaining locations will be tested after the interoperability pilot in a schedule that will be provided to acceptable Offerors described in paragraph 9 of this document. Any changes to that schedule will be well communicated to all participants during the Ft Belvoir test.
Table 1 System Version Under Test
System
Version
Offeror Frequency Band Test Bed Installation
6.2.1 Harris 380-399.9 Fort Benning or Fort Leavenworth, KS.
SR9X Harris 380-399.9 Fort Polk, LA
SR10X Harris 380-399.9 Fort Belvoir, VA or Rock Island, IL
7.5 Motorola 406.1-420 Fort Bliss, TX
7.7/7.8 Motorola 380-399.9 Ft Bragg, AL or Anniston AD, AL
7.11 Motorola 380-399.9 Fort Lee, VA or Hunter-Liggett, CA
7.13 Motorola 380-399.9 (Gordon)
138-150.8 (Rucker) Fort Gordon, GA or Fort Rucker, AL
7.14 Motorola 380-399.9
Fort Campbell, KY or Detroit Arsenal, MI
7.15 Motorola 380-399.9 Radford, VA
5 SURAC Equipment and Test Categories Subscriber Units (SU) will be broken up into two categories: First Responder (FR) and Non-First
Responder (NFR) for each LMR system in operation. All SUs shall be tested to ensure interoperability with the system versions listed in Table 1 above and any new system versions added to the contract in the future. After award, an annual testing cycle will commence to capture system upgrades for awardees in the future. Tables 2 through 7 correspond to the radio types identified in the SURAC Requirements Statement. The test tables identify which category of tests are required for each radio type. Contractors may choose to test SUs only for specific
1 OTAR - Over the Air Rekeying, OTAP -Over the Air Reprogramming, AES - Advanced Encryption Standard
SURAC TEMP Page 4 system versions or for all system versions. Contractors may choose to test all radio types identified or just specific radio types for each system. All testing expenses will be borne by the
Offeror.
Table 2 - First Responder (FR) Portable Subscriber Unit Tests
Table 2 - First Responder Portable Subscriber Unit Tests
Radio
Type General OTAP
Telephone
Interconnect
AES
Encryption
OTAR
FR
Portable 1
Attachment
A
Attachment
B
Attachment C Attachment D Attachment E
FR
Portable 2
Attachment
A
Attachment
B
Attachment C Attachment D
FR
Portable 3
Attachment
A
Attachment
B Attachment D Attachment E
FR
Portable 4
Attachment
A Attachment D Attachment E
FR
Portable 5
Attachment
A Attachment D Attachment E
FR
Portable 6
Attachment
A
Attachment
B Attachment D
FR
Portable 7
Attachment
A Attachment D
FR
Portable 8
Attachment
A Attachment D
FR
Portable 9
Attachment
A
Attachment C Attachment D Attachment E
FR
Portable 10
FR
Portable 11
Attachment D
FR
Portable 12
FR
Portable 13
Attachment
A
B
FR
Portable 14
Attachment
A
Attachment
B Attachment C Attachment D
FR
Portable 15
Attachment
A
Attachment
B
Attachment C Attachment D Attachment E
FR
Portable 16
Attachment
A
Attachment
B
Attachment C Attachment D
FR
Portable 17
Attachment
A
Attachment
B Attachment D Attachment E
FR
Portable 18
Attachment
SURAC TEMP Page 5
Table 2 - First Responder Portable Subscriber Unit Tests
Radio
Type General OTAP
Telephone
Interconnect
AES
Encryption
OTAR
FR
Portable 19
Attachment
A Attachment D Attachment E
FR
Portable 20
Attachment
A
Attachment
B Attachment D
FR
Portable 21
Attachment
A Attachment D
FR
Portable 22
Attachment
A Attachment D
FR
Portable 23
FR
Portable 24
FR
Portable 25
FR
Portable 26
FR
Portable 27
Attachment
A
Attachment
B
Attachment C Attachment D Attachment E
FR
Portable 28
Attachment
A
Attachment
B
Attachment C Attachment D
FR
Portable 29
Attachment
A
Attachment
B
Attachment C Attachment D Attachment E
FR
Portable 30
Attachment
A
Attachment
B
Attachment C Attachment D
FR
Portable 31
Attachment
A
Attachment
B Attachment D Attachment E
FR
Portable 32
Attachment
A Attachment D Attachment E
FR
Portable 33
Attachment
A Attachment D Attachment E
FR
Portable 34
Attachment
A
Attachment
B Attachment D
FR
Portable 35
Attachment
A Attachment D
FR
Portable 36
Attachment
A Attachment D
FR
Portable 37
FR
Portable 38
SURAC TEMP Page 6
Type General OTAP
Telephone
Interconnect
AES
Encryption
OTAR
FR
Portable 39
FR
Portable 40
FR
Portable 41
Attachment
A
Attachment
B
Attachment C Attachment D Attachment E
FR
Portable 42
Attachment
A
Attachment
B
Attachment C Attachment D
FR
Portable 43
Attachment
A
Attachment
B
Attachment C Attachment D Attachment E
FR
Portable 44
Attachment
A
Attachment
B
Attachment C Attachment D
FR
Portable 45
Attachment
A
Attachment
B Attachment D Attachment E
FR
Portable 46
Attachment
A Attachment D Attachment E
FR
Portable 47
Attachment
A Attachment D Attachment E
FR
Portable 48
Attachment
A
Attachment
B Attachment D
FR
Portable 49
Attachment
A Attachment D
FR
Portable 50
Attachment
A Attachment D
FR
Portable 51
FR
Portable 52
FR
Portable 53
FR
Portable 54
FR
Portable 55
Attachment
A
Attachment
B
Attachment C Attachment D Attachment E
FR
Portable 56
Attachment
A
Attachment
B
Attachment C Attachment D
FR
Portable 57
Attachment
A
Attachment
B Attachment D Attachment E
FR
Portable 58
Attachment
SURAC TEMP Page 7
Type General OTAP
Telephone
Interconnect
AES
Encryption
OTAR
FR
Portable 59
Attachment
A Attachment D Attachment E
FR
Portable 60
Attachment
A
Attachment
B Attachment D
FR
Portable 61
Attachment
A Attachment D
FR
Portable 62
Attachment
A Attachment D
FR
Portable 63
Attachment
A
Attachment
B Attachment D Attachment E
FR
Portable 64
Attachment
A Attachment D Attachment E
FR
Portable 65
Attachment
A Attachment D Attachment E
FR
Portable 66
Attachment
A
Attachment
B Attachment D
FR
Portable 67
Attachment
A Attachment D
FR
Portable 68
Attachment
Table 3 - Non-First Responder (NFR) Portable Subscriber Unit Test
Table 3 - Non-First Responder Portable Subscriber Unit Test
Radio Type General OTAP Telephone
Interconnect
AES
Encryption
OTAR
NFR Portable 1 Attachment
A
Attachment
B
Attachment
C Attachment D
Attachment
E
NFR Portable 2 Attachment
A
Attachment
B
Attachment
C Attachment D
NFR Portable 3 Attachment
A
Attachment
B
C
NFR Portable 4
A
NFR Portable 5
NFR Portable 6
NFR Portable 7
A
Attachment
B Attachment D
E
SURAC TEMP Page 8
Radio Type General OTAP Telephone
Interconnect
AES
Encryption
OTAR
NFR Portable 8 Attachment
A Attachment D
Attachment
E
NFR Portable 9 Attachment
A Attachment D
Attachment
E
NFR Portable 10 Attachment
A
Attachment
B Attachment D
NFR Portable 11 Attachment
A Attachment D
NFR Portable 12 Attachment
A Attachment D
NFR Portable 13
Attachment D
Attachment
E
NFR Portable 14
Attachment D
Attachment
E
NFR Portable 15
Attachment D
NFR Portable 16
Attachment D
NFR Portable 17
NFR Portable 18
NFR Portable 19
A
Attachment
B
Attachment
C Attachment D
Attachment
E
NFR Portable 20 Attachment
A
NFR Portable 21
A
Attachment
B
Attachment
C Attachment D
NFR Portable 22 Attachment
A
Attachment
B
NFR Portable 23
A
Attachment
B
Attachment
C Attachment D
Attachment
E
NFR Portable 24 Attachment
A
Attachment
B
Attachment
C Attachment D
NFR Portable 25 Attachment
A
Attachment
B
NFR Portable 26
A
NFR Portable 27
SURAC TEMP Page 9
Telephone
Interconnect
AES
Encryption
OTAR
NFR Portable 28
NFR Portable 29
A
Attachment
B Attachment D
Attachment
E
NFR Portable 30 Attachment
A Attachment D
Attachment
E
NFR Portable 31 Attachment
A Attachment D
Attachment
E
NFR Portable 32 Attachment
A
Attachment
B Attachment D
NFR Portable 33 Attachment
A Attachment D
NFR Portable 34 Attachment
A Attachment D
NFR Portable 35
Attachment D
Attachment
E
NFR Portable 36
Attachment D
Attachment
E
NFR Portable 37
Attachment D
NFR Portable 38
Attachment D
NFR Portable 39
NFR Portable 40
NFR Portable 41
A
Attachment
B
Attachment
C Attachment D
Attachment
E
NFR Portable 42 Attachment
A
NFR Portable 43
A
Attachment
B
Attachment
C Attachment D
NFR Portable 44 Attachment
A
Attachment
B
NFR Portable 45
A
Attachment
B
Attachment
C Attachment D
Attachment
E
NFR Portable 46 Attachment
A
Attachment
B
Attachment
C Attachment D
NFR Portable 47 Attachment
A
Attachment
B
SURAC TEMP Page 10
Telephone
Interconnect
AES
Encryption
OTAR
NFR Portable 48 Attachment
A
NFR Portable 49
NFR Portable 50
NFR Portable 51
A
Attachment
B Attachment D
Attachment
E
NFR Portable 52 Attachment
A Attachment D
Attachment
E
NFR Portable 53 Attachment
A Attachment D
Attachment
E
NFR Portable 54 Attachment
A
Attachment
B Attachment D
NFR Portable 55 Attachment
A Attachment D
NFR Portable 56 Attachment
A Attachment D
NFR Portable 57
Attachment D
Attachment
E
NFR Portable 58
Attachment D
Attachment
E
NFR Portable 59
Attachment D
NFR Portable 60
Attachment D
NFR Portable 61
NFR Portable 62
NFR Portable 63
A
Attachment
B
Attachment
C Attachment D
Attachment
E
NFR Portable 64 Attachment
A
NFR Portable 65
A
Attachment
B
Attachment
C Attachment D
NFR Portable 66 Attachment
A
Attachment
B
NFR Portable 67
A
Attachment
B
Attachment
C Attachment D
SURAC TEMP Page 11
Telephone
Interconnect
AES
Encryption
OTAR
NFR Portable 68 Attachment
A
Attachment
B
Attachment
C Attachment D
NFR Portable 69 Attachment
A
Attachment
B
NFR Portable 70
A
NFR Portable 71
NFR Portable 72
NFR Portable 73
A
Attachment
B Attachment D
Attachment
E
NFR Portable 74 Attachment
A Attachment D
Attachment
E
NFR Portable 75 Attachment
A Attachment D
Attachment
E
NFR Portable 76 Attachment
A
Attachment
B Attachment D
NFR Portable 77 Attachment
A Attachment D
NFR Portable 78 Attachment
A Attachment D
NFR Portable 79
Attachment D
Attachment
E
NFR Portable 80
Attachment D
Attachment
E
NFR Portable 81
Attachment D
NFR Portable 82
Attachment D
NFR Portable 83
NFR Portable 84
NFR Portable 85
A
Attachment
B
Attachment
C Attachment D
Attachment
E
NFR Portable 86 Attachment
A
NFR Portable 87
A
Attachment
B
Attachment
SURAC TEMP Page 12
Telephone
Interconnect
AES
Encryption
OTAR
NFR Portable 88 Attachment
A
Attachment
B
NFR Portable 89
A
Attachment
B
Attachment
C Attachment D
Attachment
E
NFR Portable 90 Attachment
A
Attachment
B
Attachment
C Attachment D
NFR Portable 91 Attachment
A
Attachment
B
NFR Portable 92
A
NFR Portable 93
NFR Portable 94
NFR Portable 95
A
Attachment
B Attachment D
Attachment
E
NFR Portable 96 Attachment
A Attachment D
Attachment
E
NFR Portable 97 Attachment
A Attachment D
Attachment
E
NFR Portable 98 Attachment
A
Attachment
B Attachment D
NFR Portable 99 Attachment
A Attachment D
NFR Portable
Attachment
A Attachment D
NFR Portable
Attachment D
Attachment
E
NFR Portable
Attachment D
Attachment
E
NFR Portable
Attachment D
NFR Portable
Attachment D
NFR Portable
NFR Portable
Attachment
A
Attachment
B
Attachment
C Attachment D
SURAC TEMP Page 13
Telephone
Interconnect
AES
Encryption
OTAR
NFR Portable
Attachment
A
Attachment
A
Attachment
B
Attachment
C Attachment D
NFR Portable
Attachment
A
Attachment
B
Attachment
A
Attachment
B
Attachment
C Attachment D
Attachment
E
NFR Portable
Attachment
A
Attachment
B
Attachment
C Attachment D
NFR Portable
Attachment
A
Attachment
B
Attachment
A
Attachment
A
Attachment
B Attachment D
Attachment
E
NFR Portable
Attachment
A Attachment D
Attachment
E
NFR Portable
Attachment
A Attachment D
Attachment
E
NFR Portable
Attachment
A
Attachment
B Attachment D
NFR Portable
Attachment
A Attachment D
NFR Portable
Attachment
A Attachment D
NFR Portable
Attachment D
Attachment
E
NFR Portable
Attachment D
Attachment
E
NFR Portable
Attachment D
NFR Portable
Attachment D
NFR Portable
SURAC TEMP Page 14
Telephone
Interconnect
AES
Encryption
OTAR
NFR Portable
Attachment
A
Attachment
B
Attachment
C Attachment D
Attachment
E
NFR Portable
Attachment
A
Attachment
A
Attachment
B
Attachment
C Attachment D
NFR Portable
Attachment
A
Attachment
B
Table 4 - First Responder (FR) Mobile Subscriber Unit Test
Table 4 - First Responder Mobile Subscriber Unit Test
Telephone
Interconnect
AES
Encryption
OTAR
FR Mobile 1 Attachment
A
Attachment
B Attachment C
Attachment
D
Attachment
E
FR Mobile 2 Attachment
A
Attachment
B Attachment C
D
FR Mobile 3
A
Attachment
E
FR Mobile 4
Attachment
E
FR Mobile 5 Attachment
A
FR Mobile 6
FR Mobile 7
A Attachment C
Attachment
D
Attachment
E
FR Mobile 8 Attachment
A Attachment C
FR Mobile 9
A
Attachment
B Attachment C
Attachment
D
Attachment
E
FR Mobile 10 Attachment
A
Attachment
B Attachment C
FR Mobile 11
A
Attachment
E
FR Mobile 12
SURAC TEMP Page 15
Telephone
Interconnect
AES
Encryption
OTAR
FR Mobile 13 Attachment
A
FR Mobile 14
FR Mobile 15
A Attachment C
Attachment
D
Attachment
E
FR Mobile 16 Attachment
A Attachment C
FR Mobile 17
A
Attachment
B Attachment C
Attachment
D
Attachment
E
FR Mobile 18 Attachment
A
Attachment
B Attachment C
FR Mobile 19
A
Attachment
E
FR Mobile 20
Attachment
E
FR Mobile 21 Attachment
A
FR Mobile 22
FR Mobile 23
A Attachment C
Attachment
D
Attachment
E
FR Mobile 24 Attachment
A Attachment C
FR Mobile 25
A
Attachment
B Attachment C
Attachment
D
Attachment
E
FR Mobile 26 Attachment
A
Attachment
B Attachment C
FR Mobile 27
A
Attachment
E
FR Mobile 28
Attachment
E
FR Mobile 29 Attachment
A
FR Mobile 30
FR Mobile 31
A Attachment C
Attachment
D
Attachment
E
FR Mobile 32 Attachment
A Attachment C
SURAC TEMP Page 16
Telephone
Interconnect
AES
Encryption
OTAR
FR Mobile 33 Attachment
A
Attachment
B Attachment C
Attachment
D
Attachment
E
FR Mobile 34 Attachment
A
Attachment
B Attachment C
FR Mobile 35
A
Attachment
E
FR Mobile 36
Attachment
E
FR Mobile 37 Attachment
A
FR Mobile 38
FR Mobile 39
A Attachment C
Attachment
D
Attachment
E
FR Mobile 40 Attachment
A Attachment C
FR Mobile 41
A
Attachment
B Attachment C
Attachment
D
Attachment
E
FR Mobile 42 Attachment
A
Attachment
B Attachment C
FR Mobile 43
A
Attachment
E
FR Mobile 44
Attachment
E
FR Mobile 45 Attachment
A
FR Mobile 46
FR Mobile 47
A Attachment C
Attachment
D
Attachment
E
FR Mobile 48 Attachment
A Attachment C
FR Mobile 49
A
Attachment
B Attachment C
Attachment
D
Attachment
E
FR Mobile 50 Attachment
A
Attachment
B Attachment C
FR Mobile 51
A
Attachment
E
FR Mobile 52
SURAC TEMP Page 17
Telephone
Interconnect
AES
Encryption
OTAR
FR Mobile 53 Attachment
A
FR Mobile 54
FR Mobile 55
A Attachment C
Attachment
D
Attachment
E
FR Mobile 56 Attachment
A Attachment C
FR Mobile 57
A
Attachment
B Attachment C
Attachment
D
Attachment
E
FR Mobile 58 Attachment
A
Attachment
B Attachment C
FR Mobile 59
A
Attachment
E
FR Mobile 60
Attachment
E
FR Mobile 61 Attachment
A
FR Mobile 62
FR Mobile 63
A Attachment C
Attachment
D
Attachment
E
FR Mobile 64 Attachment
A Attachment C
FR Mobile 65
A
Attachment
B Attachment C
Attachment
D
Attachment
E
FR Mobile 66 Attachment
A
Attachment
B Attachment C
FR Mobile 67
A
Attachment
E
FR Mobile 68
Attachment
E
FR Mobile 69 Attachment
A
FR Mobile 70
FR Mobile 71
A Attachment C
Attachment
D
Attachment
E
FR Mobile 72 Attachment
A Attachment C
SURAC TEMP Page 18
Telephone
Interconnect
AES
Encryption
OTAR
FR Mobile 73 Attachment
A
Attachment
B Attachment C
Attachment
D
Attachment
E
FR Mobile 74 Attachment
A
Attachment
B Attachment C
FR Mobile 75
A
Attachment
E
FR Mobile 76
Attachment
E
FR Mobile 77 Attachment
A
FR Mobile 78
FR Mobile 79
A Attachment C
Attachment
D
Attachment
E
FR Mobile 80 Attachment
A Attachment C
FR Mobile 81
A
Attachment
B Attachment C
Attachment
D
Attachment
E
FR Mobile 82 Attachment
A
Attachment
B Attachment C
FR Mobile 83
A
Attachment
E
FR Mobile 84
Attachment
E
FR Mobile 85 Attachment
A
FR Mobile 86
FR Mobile 87
A Attachment C
Attachment
D
Attachment
E
FR Mobile 88 Attachment
A Attachment C
FR Mobile 89
A
Attachment
B Attachment C
Attachment
D
Attachment
E
FR Mobile 90 Attachment
A
Attachment
B Attachment C
FR Mobile 91
A
Attachment
E
FR Mobile 92
SURAC TEMP Page 19
Telephone
Interconnect
AES
Encryption
OTAR
FR Mobile 93 Attachment
A
FR Mobile 94
FR Mobile 95
A Attachment C
Attachment
D
Attachment
E
FR Mobile 96 Attachment
A Attachment C
FR Mobile 97
A
Attachment
B Attachment C
Attachment
D
Attachment
E
FR Mobile 98 Attachment
A
Attachment
B Attachment C
FR Mobile 99
A
Attachment
E
FR Mobile 100
Attachment
E
FR Mobile 101 Attachment
A
FR Mobile 102
FR Mobile 103
A Attachment C
Attachment
D
Attachment
E
FR Mobile 104 Attachment
A Attachment C
FR Mobile 105
A
Attachment
B Attachment C
Attachment
D
Attachment
E
FR Mobile 106 Attachment
A
Attachment
B Attachment C
FR Mobile 107
A
Attachment
E
FR Mobile 108
Attachment
E
FR Mobile 109 Attachment
A
FR Mobile 110
FR Mobile 111
A Attachment C
Attachment
D
Attachment
E
FR Mobile 112 Attachment
A Attachment C
SURAC TEMP Page 20
Table 5 - Non-First Responder (NFR) Mobile Subscriber Unit Test
Table 5 - Non-First Responder Mobile Subscriber Unit Test
Radio Type General OTAP Telephone
Interconnect
AES
Encryption
OTAR
NFR Mobile 1 Attachment
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Mobile 2 Attachment
A
Attachment
B
Attachment
C
NFR Mobile 3
A
Attachment
B
NFR Mobile 4
A
NFR Mobile 5
NFR Mobile 6
A
Attachment
E
NFR Mobile 7
Attachment
E
NFR Mobile 8 Attachment
A
NFR Mobile 9
NFR Mobile 10
Attachment
D
Attachment
E
NFR Mobile 11
NFR Mobile 12
NFR Mobile 13
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Mobile 14 Attachment
A
Attachment
B
Attachment
C
NFR Mobile 15
A
Attachment
B
NFR Mobile 16
A
NFR Mobile 17
NFR Mobile 18
A
Attachment
E
NFR Mobile 19
Attachment
E
NFR Mobile 20 Attachment
A
SURAC TEMP Page 21
Telephone
Interconnect
AES
Encryption
OTAR
NFR Mobile 21
NFR Mobile 22
Attachment
D
Attachment
E
NFR Mobile 23
NFR Mobile 24
NFR Mobile 25
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Mobile 26 Attachment
A
Attachment
B
Attachment
C
NFR Mobile 27
A
Attachment
B
NFR Mobile 28
A
NFR Mobile 29
NFR Mobile 30
A
Attachment
E
NFR Mobile 31
Attachment
E
NFR Mobile 32 Attachment
A
NFR Mobile 33
NFR Mobile 34
Attachment
D
Attachment
E
NFR Mobile 35
NFR Mobile 36
NFR Mobile 37
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Mobile 38 Attachment
A
Attachment
B
Attachment
C
NFR Mobile 39
A
Attachment
B
NFR Mobile 40
A
SURAC TEMP Page 22
Telephone
Interconnect
AES
Encryption
OTAR
NFR Mobile 41
NFR Mobile 42
A
Attachment
E
NFR Mobile 43
Attachment
E
NFR Mobile 44 Attachment
A
NFR Mobile 45
NFR Mobile 46
Attachment
D
Attachment
E
NFR Mobile 47
NFR Mobile 48
NFR Mobile 49
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Mobile 50 Attachment
A
Attachment
B
Attachment
C
NFR Mobile 51
A
Attachment
B
NFR Mobile 52
A
NFR Mobile 53
NFR Mobile 54
A
Attachment
E
NFR Mobile 55
Attachment
E
NFR Mobile 56 Attachment
A
NFR Mobile 57
NFR Mobile 58
Attachment
D
Attachment
E
NFR Mobile 59
NFR Mobile 60
SURAC TEMP Page 23
Telephone
Interconnect
AES
Encryption
OTAR
NFR Mobile 61 Attachment
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Mobile 62 Attachment
A
Attachment
B
Attachment
C
NFR Mobile 63
A
Attachment
B
NFR Mobile 64
A
NFR Mobile 65
NFR Mobile 66
A
Attachment
E
NFR Mobile 67
Attachment
E
NFR Mobile 68 Attachment
A
NFR Mobile 69
NFR Mobile 70
Attachment
D
Attachment
E
NFR Mobile 71
NFR Mobile 72
NFR Mobile 73
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Mobile 74 Attachment
A
Attachment
B
Attachment
C
NFR Mobile 75
A
Attachment
B
NFR Mobile 76
A
NFR Mobile 77
NFR Mobile 78
A
Attachment
E
NFR Mobile 79
Attachment
E
NFR Mobile 80 Attachment
A
SURAC TEMP Page 24
Telephone
Interconnect
AES
Encryption
OTAR
NFR Mobile 81
NFR Mobile 82
Attachment
D
Attachment
E
NFR Mobile 83
NFR Mobile 84
NFR Mobile 85
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Mobile 86 Attachment
A
Attachment
B
Attachment
C
NFR Mobile 87
A
Attachment
B
NFR Mobile 88
A
NFR Mobile 89
NFR Mobile 90
A
Attachment
E
NFR Mobile 91
Attachment
E
NFR Mobile 92 Attachment
A
NFR Mobile 93
NFR Mobile 94
Attachment
D
Attachment
E
NFR Mobile 95
NFR Mobile 96
NFR Mobile 97
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Mobile 98 Attachment
A
Attachment
B
Attachment
C
NFR Mobile 99
A
Attachment
B
NFR Mobile 100
A
SURAC TEMP Page 25
Telephone
Interconnect
AES
Encryption
OTAR
NFR Mobile 101
NFR Mobile 102
A
Attachment
E
NFR Mobile 103
Attachment
E
NFR Mobile 104 Attachment
A
NFR Mobile 105
NFR Mobile 106
Attachment
D
Attachment
E
NFR Mobile 107
NFR Mobile 108
NFR Mobile 109
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Mobile 110 Attachment
A
Attachment
B
Attachment
C
NFR Mobile 111
A
Attachment
B
NFR Mobile 112
A
NFR Mobile 113
NFR Mobile 114
A
Attachment
E
NFR Mobile 115
Attachment
E
NFR Mobile 116 Attachment
A
NFR Mobile 117
NFR Mobile 118
Attachment
D
Attachment
E
NFR Mobile 119
NFR Mobile 120
SURAC TEMP Page 26
Telephone
Interconnect
AES
Encryption
OTAR
NFR Mobile 121 Attachment
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Mobile 122 Attachment
A
Attachment
B
Attachment
C
NFR Mobile 123
A
Attachment
B
NFR Mobile 124
A
NFR Mobile 125
NFR Mobile 126
A
Attachment
E
NFR Mobile 127
Attachment
E
NFR Mobile 128 Attachment
A
NFR Mobile 129
NFR Mobile 130
Attachment
D
Attachment
E
NFR Mobile 131
NFR Mobile 132
NFR Mobile 133
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Mobile 134 Attachment
A
Attachment
B
Attachment
C
NFR Mobile 135
A
Attachment
B
NFR Mobile 136
A
NFR Mobile 137
NFR Mobile 138
A
Attachment
E
NFR Mobile 139
Attachment
E
NFR Mobile 140 Attachment
A
SURAC TEMP Page 27
Telephone
Interconnect
AES
Encryption
OTAR
NFR Mobile 141
NFR Mobile 142
Attachment
D
Attachment
E
NFR Mobile 143
NFR Mobile 144
NFR Mobile 145
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Mobile 146 Attachment
A
Attachment
B
Attachment
C
NFR Mobile 147
A
Attachment
B
NFR Mobile 148
A
NFR Mobile 149
NFR Mobile 150
A
Attachment
E
NFR Mobile 151
Attachment
E
NFR Mobile 152 Attachment
A
NFR Mobile 153
NFR Mobile 154
Attachment
D
Attachment
E
NFR Mobile 155
NFR Mobile 156
NFR Mobile 157
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Mobile 158 Attachment
A
Attachment
B
Attachment
C
NFR Mobile 159
A
Attachment
B
NFR Mobile 160
A
SURAC TEMP Page 28
Telephone
Interconnect
AES
Encryption
OTAR
NFR Mobile 161
NFR Mobile 162
A
Attachment
E
NFR Mobile 163
Attachment
E
NFR Mobile 164 Attachment
A
NFR Mobile 165
NFR Mobile 166
Attachment
D
Attachment
E
NFR Mobile 167
NFR Mobile 168
Table 6 - First Responder (FR) Desktop Subscriber Unit Test
Table 6 - First Responder Desktop Subscriber Unit Test
Radio Type General OTAP Telephone
Interconnect
AES
Encryption
OTAR
FR Desktop 1 Attachment A Attachment
B
Attachment
C
Attachment
D
Attachment
E
FR Desktop 2 Attachment A Attachment
B
Attachment
C
FR Desktop 3 Attachment A
Attachment
E
FR Desktop 4 Attachment A Attachment
D
Attachment
E
FR Desktop 5 Attachment A
FR Desktop 6 Attachment A
FR Desktop 7 Attachment A
C
Attachment
D
Attachment
E
FR Desktop 8 Attachment A Attachment
C
FR Desktop 9 Attachment A
B
Attachment
C
Attachment
D
SURAC TEMP Page 29
Telephone
Interconnect
AES
Encryption
OTAR
FR Desktop 10 Attachment A Attachment
B
Attachment
C
FR Desktop 11 Attachment A
Attachment
E
FR Desktop 12 Attachment A Attachment
D
Attachment
E
FR Desktop 13 Attachment A
FR Desktop 14 Attachment A
FR Desktop 15 Attachment A
C
Attachment
D
Attachment
E
FR Desktop 16 Attachment A Attachment
C
FR Desktop 17 Attachment A
B
Attachment
C
Attachment
D
Attachment
E
FR Desktop 18 Attachment A Attachment
B
Attachment
C
FR Desktop 19 Attachment A
Attachment
E
FR Desktop 20 Attachment A Attachment
D
Attachment
E
FR Desktop 21 Attachment A
FR Desktop 22 Attachment A
FR Desktop 23 Attachment A
C
Attachment
D
Attachment
E
FR Desktop 24 Attachment A Attachment
C
FR Desktop 25 Attachment A
B
Attachment
C
Attachment
D
Attachment
E
FR Desktop 26 Attachment A Attachment
B
Attachment
C
FR Desktop 27 Attachment A
Attachment
E
FR Desktop 28 Attachment A Attachment
D
Attachment
E
FR Desktop 29 Attachment A
SURAC TEMP Page 30
Telephone
Interconnect
AES
Encryption
OTAR
FR Desktop 30 Attachment A
FR Desktop 31 Attachment A
C
Attachment
D
Attachment
E
FR Desktop 32 Attachment A Attachment
C
FR Desktop 33 Attachment A
B
Attachment
C
Attachment
D
Attachment
E
FR Desktop 34 Attachment A Attachment
B
Attachment
C
FR Desktop 35 Attachment A
Attachment
E
FR Desktop 36 Attachment A Attachment
D
Attachment
E
FR Desktop 37 Attachment A
FR Desktop 38 Attachment A
FR Desktop 39 Attachment A
C
Attachment
D
Attachment
E
FR Desktop 40 Attachment A Attachment
C
FR Desktop 41 Attachment A
B
Attachment
C
Attachment
D
Attachment
E
FR Desktop 42 Attachment A Attachment
B
Attachment
C
FR Desktop 43 Attachment A
Attachment
E
FR Desktop 44 Attachment A Attachment
D
Attachment
E
FR Desktop 45 Attachment A
FR Desktop 46 Attachment A
FR Desktop 47 Attachment A
C
Attachment
D
Attachment
E
FR Desktop 48 Attachment A Attachment
C
FR Desktop 49 Attachment A
B
Attachment
C
Attachment
D
SURAC TEMP Page 31
Telephone
Interconnect
AES
Encryption
OTAR
FR Desktop 50 Attachment A Attachment
B
Attachment
C
FR Desktop 51 Attachment A
Attachment
E
FR Desktop 52 Attachment A Attachment
D
Attachment
E
FR Desktop 53 Attachment A
FR Desktop 54 Attachment A
FR Desktop 55 Attachment A
C
Attachment
D
Attachment
E
FR Desktop 56 Attachment A Attachment
C
FR Desktop 57 Attachment A
B
Attachment
C
Attachment
D
Attachment
E
FR Desktop 58 Attachment A Attachment
B
Attachment
C
FR Desktop 59 Attachment A
Attachment
E
FR Desktop 60 Attachment A Attachment
D
Attachment
E
FR Desktop 61 Attachment A
FR Desktop 62 Attachment A
FR Desktop 63 Attachment A
C
Attachment
D
Attachment
E
FR Desktop 64 Attachment A Attachment
C
Table 7 - Non-First Responder (NFR) Desktop Subscriber Unit Test
Table 7 - Non-First Responder Desktop Subscriber Unit Test
Radio Type General OTAP Telephone
Interconnect
AES
Encryption
OTAR
NFR Desktop 1 Attachment
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Desktop 2 Attachment
A
Attachment
B
Attachment
C
SURAC TEMP Page 32
Telephone
Interconnect
AES
Encryption
OTAR
NFR Desktop 3 Attachment
A
Attachment
B
NFR Desktop 4
A
NFR Desktop 5
NFR Desktop 6
A
Attachment
E
NFR Desktop 7
Attachment
E
NFR Desktop 8 Attachment
A
NFR Desktop 9
NFR Desktop 10
Attachment
D
Attachment
E
NFR Desktop 11
NFR Desktop 12
NFR Desktop 13
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Desktop 14 Attachment
A
Attachment
B
Attachment
C
NFR Desktop 15
A
Attachment
B
NFR Desktop 16
A
NFR Desktop 17
NFR Desktop 18
A
Attachment
E
NFR Desktop 19
Attachment
E
NFR Desktop 20 Attachment
A
NFR Desktop 21
NFR Desktop 22
Attachment
D
SURAC TEMP Page 33
Telephone
Interconnect
AES
Encryption
OTAR
NFR Desktop 23
NFR Desktop 24
NFR Desktop 25
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Desktop 26 Attachment
A
Attachment
B
Attachment
C
NFR Desktop 27
A
Attachment
B
NFR Desktop 28
A
NFR Desktop 29
NFR Desktop 30
A
Attachment
E
NFR Desktop 31
Attachment
E
NFR Desktop 32 Attachment
A
NFR Desktop 33
NFR Desktop 34
Attachment
D
Attachment
E
NFR Desktop 35
NFR Desktop 36
NFR Desktop 37
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Desktop 38 Attachment
A
Attachment
B
Attachment
C
NFR Desktop 39
A
Attachment
B
NFR Desktop 40
A
NFR Desktop 41
NFR Desktop 42
A
SURAC TEMP Page 34
Telephone
Interconnect
AES
Encryption
OTAR
NFR Desktop 43
Attachment
E
NFR Desktop 44 Attachment
A
NFR Desktop 45
NFR Desktop 46
Attachment
D
Attachment
E
NFR Desktop 47
NFR Desktop 48
NFR Desktop 49
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Desktop 50 Attachment
A
Attachment
B
Attachment
C
NFR Desktop 51
A
Attachment
B
NFR Desktop 52
A
NFR Desktop 53
NFR Desktop 54
A
Attachment
E
NFR Desktop 55
Attachment
E
NFR Desktop 56 Attachment
A
NFR Desktop 57
NFR Desktop 58
Attachment
D
Attachment
E
NFR Desktop 59
NFR Desktop 60
NFR Desktop 61
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Desktop 62 Attachment
A
Attachment
B
Attachment
C
SURAC TEMP Page 35
Telephone
Interconnect
AES
Encryption
OTAR
NFR Desktop 63 Attachment
A
Attachment
B
NFR Desktop 64
A
NFR Desktop 65
NFR Desktop 66
A
Attachment
E
NFR Desktop 67
Attachment
E
NFR Desktop 68 Attachment
A
NFR Desktop 69
NFR Desktop 70
Attachment
D
Attachment
E
NFR Desktop 71
NFR Desktop 72
NFR Desktop 73
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Desktop 74 Attachment
A
Attachment
B
Attachment
C
NFR Desktop 75
A
Attachment
B
NFR Desktop 76
A
NFR Desktop 77
NFR Desktop 78
A
Attachment
E
NFR Desktop 79
Attachment
E
NFR Desktop 80 Attachment
A
NFR Desktop 81
NFR Desktop 82
Attachment
D
SURAC TEMP Page 36
Telephone
Interconnect
AES
Encryption
OTAR
NFR Desktop 83
NFR Desktop 84
NFR Desktop 85
A
Attachment
B
Attachment
C
Attachment
D
Attachment
E
NFR Desktop 86 Attachment
A
Attachment
B
Attachment
C
NFR Desktop 87
A
Attachment
B
NFR Desktop 88
A
NFR Desktop 89
NFR Desktop 90
A
Attachment
E
NFR Desktop 91
Attachment
E
NFR Desktop 92 Attachment
A
NFR Desktop 93
NFR Desktop 94
Attachment
D
Attachment
E
NFR Desktop 95
NFR Desktop 96
6 Government Assumptions In an effort to streamline interoperability testing, the Army has made the following assumptions:
Frequency band will not impact test results. Offerors will test SU models in the band identified for each system. Therefore, both Ultra High Frequency (UHF) and Very High
Frequency (VHF) versions of each SU model will not be tested. However, all J/F 12 and ruggedized, submersible, Hazardous Location must be provided for each frequency band proposed.
SU models that pass the most comprehensive tests (AES, Telephone Interconnect, OTAR, and OTAP) do not need to be re-tested for different radio types requiring those
SURAC TEMP Page 37 features. For example, if an Offeror tests a First Responder (FR) Portable 1 (the most comprehensive) and passes all tests, that SU model does not need to be re-tested to be proposed for a less comprehensive radio need. Key pad differences will require testing each type of keypad proposed. A cross-reference of features correlation to tests is provided in Appendix B.
The form, fit and function of the equipment version may be technically equal between some SU radio versions. In order to decrease Offerors expense of testing all equipment, Offerors will be given the opportunity to provide a Certificate of Conformance for versions that are technically compatible.
A Desktop SU is the same as a Mobile SU. The Offeror will provide a Desktop SU for testing. That Desktop SU will be accepted for all Mobile SU testing of same features/functions for that specific model.
All parameters that have the possibility of impacting terminal equipment performance are set to values that will allow all vendor terminal products to be properly evaluated.
Ruggedized, Submersible, and Hazardous Location will not be tested. The Offeror shall provide documentation of successful factory testing of these features in order to be considered. Factory Mutual (FM) Intrinsically Safe (IS) or Underwriter Laboratories
(UL) “HazLoc” certification are acceptable.
Control heads have no impact on testing SU types.
7 Offeror Required Test Equipment Offerors are responsible for providing all equipment for the test, such as; subscriber units, programming platforms, cables and accessories to each testing location. Legacy subscriber units will be available for testing interoperability between proposed equipment and legacy systems.
All proposed radio types must be tested as described within the guidelines in the APL Technical
Acceptance section. Interoperability tests will require the following (at a minimum):
Each type of subscriber unit (including all accessories required for operation)
Key management (KVL/KMF)
Spare battery
Battery charger
Programming Platform, including interface cables
Desktop/Mobile Subscriber units (any required cabling and accessories)
Scanning tool (platform)
Removable media: CD or DVD (to dump setup scans). Flash media is not allowed.
8 Test Team Composition The Test Team shall consist of the following:
SURAC TEMP Page 38
PL LMR Lead
United States Army Information Systems Engineering Command Fort Detrick
Engineering Directorate (USAISEC-FDED) engineer(s)
Installation Network Enterprise Center (NEC)-LMR Administrator(s)
Cybersecurity Team (USAISEC)
No more than three Offeror Representatives at each location
9 APL Technical Acceptance Validation testing will be completed to ensure interoperability with the current system versions listed in Table 1 and consists of several steps.
9.1 Step 1 – Identification of System Version, Radio Type, and OEM – Go/No Go
The Offeror shall provide a technical proposal to the Army Contracting Command-Rock Island
(ACC-RI) Contracting team that contains a list of system versions and radio types. Radio type(s) identified shall correspond to the radio types described in the Requirements Statement. The
Offeror shall complete the Equipment Submission Form (Attachment 0002 of the RFP) for each radio version being proposed. Offerors shall fill in the CLIN number and description (as listed on the Price Matrix) in the first column, name of the proposed radio version in the second column, and a “Yes” in appropriate columns for the system version(s) that apply. Leave the column blank if the system version does not apply. In addition to completing the Equipment
Submission form, Offerors shall submit the following information for each subscriber model proposed as part of their technical proposal.
Inter-department Radio Advisory Committee (IRAC) document
J/F-12 and Spectrum Planning Subcommittee numbers
Approval to operate on all DoD LMR frequency bands (VHF/UHF). The Offeror shall provide a statement that summarizes the received approval (i.e. spectrum documentation) to operate on the DoD LMR frequency bands for each radio proposed. The statement shall include the radio nomenclature as identified on the spectrum documentation, the approved frequency ranges and emission designators.
For all proposed radio versions which have not received spectrum approval (Approval to operate on DoD frequencies), the Offeror shall submit a copy of the “Request to
Demonstrate” submitted to the Federal Communications Commission (FCC) for proposed equipment on a trunked system which identifies the locations and system versions affected. This copy shall indicate when the “Request to Demonstrate” was submitted to the FCC and to whom it was submitted.
Factory test documentation for ruggedized housing, submersible, Factory Mutual and
Hazardous Location (Haz Loc)
FIPS 140-2 Certification Number and version numbers
Any system specific information required by the Offeror for SU programming (i.e., system ID, WACN ID, Radio Serial Numbers, etc.) The Government will provide Talk
Group Names/Aliases to be used in Sections 9.2, 9.5 and 9.6 of the TEMP.
SURAC TEMP Page 39
Programming Software configuration needs for proposed equipment
Certificate of Conformance waiving interoperability testing on listed Radio Types and acceptance of actual damages if in error (if applicable). The Certificate of Conformance addresses the operation of the firmware and mandatory P25 features/functions for the radios that would be validated in Section 9.6 of the TEMP. The Certificate of
Conformance DOES NOT address performance covered by the Spectrum Approval process (i.e. JF-12, SPS, IRAC). All proposed radios must have Spectrum Approval or
FCC Approval to Demonstrate.
Offeror’s definition of identified Emission Designations
Offeror’s number of Talk Groups requested for Interoperability demonstration/testing should the Offeror proceed to testing
Written proof that they are an OEM of proposed LMR subscriber equipment or have and provide written proof of a business partnership or agreement, specifically for the SURAC effort, with a LMR subscriber equipment OEM.
If the documentation is complete and valid for the radio type proposed, the Offeror will receive a
“Go” decision from the Government and the Offeror will be provided information to scan the programming platform(s) and a test schedule. The validation is completed by reviewing the database of the IRAC/JF-12 and spectrum planning subcommittee numbers.
If documentation cannot be validated or is incomplete, the Offeror will receive a “No Go” decision and will not proceed to the next step of validation testing this cycle.
Note: Once an Offeror receives the “Go” decision to proceed to the next step, the Offeror cannot change or substitute radio types to be tested.
9.2 Test Scenario, Case and Script Development and Execution
As each Offeror may vary in how they meet the requirements, each Offeror receiving a “Go” decision from Step 1 shall develop detailed test scripts for each test case scenario needed for the radio type proposed. Test case scenarios are organized into attachments to this document:
General, OTAP, Telephone Interconnect, AES Encryption, and OTAR. Test scenarios and test cases are provided by the Government and contain APCO P25 and non-APCO P25 tests as well as integrated testing such as Patching, Simul-Select, Emergency Declaration, and Mutual Aid
Interoperability. Offerors shall modify these test case scenario documents by expanding them to identify each step needed to prove the test case scenario in a test script. Tests may require the interaction with the Offerors radios, local radios, and local consoles. Test Frequencies, test talk groups, and console operators will be provided by the Government where required. The Offeror must identify where this interaction is required when submitting test scripts. In addition to the test scripts, the Offeror shall matrix the test case scenarios, test cases, and test results into a Test
Completion Results document using the form in Appendix C.
SURAC TEMP Page 40
Test Case Scenarios need only be detailed into test scripts for those radio types proposed (e.g., if the Offeror is not testing OTAP, test scripts for OTAP test cases do not need to be provided).
Since the system configuration may impact the test script steps, the proposal will include a dry run of test scripts to give Offerors time to correct any test script errors. Please see section 9.4
Step 3 Test Set up for details regarding dry run tests. Once formal testing begins, the test scripts must be followed exactly as written during on site testing. If the test script is not followed exactly the test will be marked as failed, and the equipment will not be technically acceptable. The Offeror will not move to step 2 – Pre-Test Programming Platform
Validation Procedures for any test scripts that fail.
9.3 Step 2 - Pre-Test Programming Platform Validation Procedures – Go/No Go
All Offerors receiving a “Go” decision from Step 1 will undergo a preliminary cybersecurity screening. Each Offeror shall pre-scan the programming platform(s) while hardening the programming platform with the applicable programming software versions technical security controls, settings, and mitigation measures identified by the Department of Defense Instruction
(DoDI) 8500.2, AR 25-2 and Defense Information Systems Agency (DISA) Security Technical
Implementation Guides (STIG) prior to Security Compliance Assessment. In addition to the scan results, the Offeror shall provide the ACC-RI Contracting team with a document that lists all controls NOT implemented IAW the DoDI 8500.2, AR 25-2, and all current applicable DISA
STIGs. The document shall also provide justification as to why any technical security controls, settings, and mitigation measures were NOT applied.
The Offeror shall provide the results of the pre-scan, documentation of controls, and one programming platform to the ACC-RI Contracting team who will provide it to the Information
Systems Engineering Command (ISEC) Cybersecurity team. The Cybersecurity team will review the documentation provided and conduct an assessment of the programming platform. The
Offeror will receive a “Go/No Go” decision based on the assessment. To receive a “Go” decision the programming platform must be hardened with the applicable STIGS, meet technical needs and have favorable assessment results. Any Offeror who meets these standards and provides sound mitigation that does not compromise cybersecurity will receive a favorable assessment.
If a programming platform should not meet the standards referenced in the Requirements
Statement, the Offeror will receive a “No Go” decision and associated SU will not be technically acceptable and will not move forward to step 3.
9.4 Subscriber Unit Test Date and Test Plan
Offerors who receive a Step 2 - Pre-Test Programming Platform “Go” decision will be provided test dates and locations. Changes to the test date scheduled must be coordinated with Army
Contracting Command-Rock Island and may not be flexible. Should the Offeror not be able to meet a test date that cannot be moved, the Offerors will be deemed ineligible. Any Offeror who receives a “No-Go” will have the opportunity to demonstrate capability during an on-ramp cycle.
SURAC TEMP Page 41
9.5 Step 3 - Test Set-Up – Go/No Go
All Offerors receiving a “Go” decision from Step 2 will utilize the first day of testing to set up and conduct an on-site Information Assurance Security Engineering Directorate (ISAED), or
ISEC, Certification and Accreditation Toolset (ICAT) scan of the programming platform. The
ISEC engineer on-site will verify the configuration and observe the scan. Each Offeror will scan the programming platform and provide scan results via CD/DVD to the ISEC engineer on-site and the ACC-RI Contracting team. The ISEC engineer will send the scan results to the ISEC
Cybersecurity team to validate the scans with the system information gathered from the pre-test programming platform validation. The ISEC Cybersecurity team will send a “Go” or “No Go” decision within 48 hours to the on-site ISEC engineer who in turn will notify the ACC-RI
Contracting team who will send the “Go” or “No Go” decision to the Offeror.
To receive a “Go” decision, the on-site programming platform must match the baseline hardened during the Pre-Test Programming Platform Validation. If a “Go” is received, the Offeror may proceed immediately into a dry run of their detailed test scripts against the legacy system. The dry run affords each Offeror the opportunity to modify radio configuration and test scripts where the legacy system may impact the procedures. Local support staff will be available for consultation with all test participants throughout testing events, including the pre-test dry run.
Offerors may modify their detailed test scripts during the dry run. An electronic version and two hardcopies of the modified test scripts are deliverables that shall be provided to the on location
POC and an electronic version shall be provided to the ACC-RI Contracting team.
Offerors shall document any issues that arise that cannot be resolved via a test script or radio configuration change. If a configuration change is needed that does not violate the ATO for the platform, the ISEC engineer, Test Lead, and Contracting Officer may allow the configuration change and allow the test to continue. If a change is needed that violates the ATO, the Offeror will not be allowed to proceed. If a “No Go” is received, the Offeror will not be allowed to proceed with testing.
The Offeror shall scan, copy and provide electronic and hardcopies of any redlined test scripts to the Government prior to the commencement of the interoperability tests.
9.6 Step 4 - Interoperability Test Execution
The Government witnessed Interoperability Test shall include testing of all equipment and will be strictly based on the pass/fail criteria in the test procedures. If a test is successfully executed, that feature is deemed to be compliant and results in a Pass. Failed tests cannot be repeated or modified. If an Offeror’s item of equipment is deemed to be malfunctioning, and a duplicate item of equipment configured exactly the same is available to test, the test may be executed on that piece of Offeror’s equipment. Configuration of a replacement item will be validated by the
Government SME and/or ISEC engineer on site. If the test is successful on the duplicate equipment, the feature will be deemed compliant and results in a Pass. The Offeror will annotate on the test any situation when equipment is replaced.
SURAC TEMP Page 42
In test cases where more than one radio is required, an Offeror’s SU will be used as well as a legacy SU to test compatibility.
Any SU radio type which passes all required tests for that radio type will be technically acceptable.
Any issues found during testing will be recorded on the test form. Successful or failed execution of each test results in recording of initials from both the Offeror and Government witnesses.
10 Government Responsibilities The Government will be responsible for the following during the Pre-test and Testing.
10.1 Government Pre-Test Responsibilities
Validate SPS/IRAC/JF-12 documentation
Validate FIPS certification
Provide “Go/No Go” for Statement of Intent documentation (Step 1)
Provide the list of applicable test case scenarios and Test Correlation Tables
Provide cybersecurity scan configuration
Conduct programming platform assessment
Provide “Go/No Go” for pre-test programming platform assessment (Step 2)
Provide test date for each system and test location
Provide test location system…