This is a Questions & Answers document for federal contract opportunity W51AA1-26-Q-A079 Tower Inspection and Maintenance, dated August 6, 2026.

A contractor submitted a question on August 5, 2026, requesting detailed specifications and quantities for materials required under CLIN 0003 to accurately price the material portion of the contract. The contractor sought clarification on multiple Performance Work Statement (PWS) requirements across four tower structures: the LMR Tower, Building 32 Platform, 100 Ft Tower Track Tower, and 330 Ft Tower. Specific requests included quantities and specifications for RF radiation and high-voltage warning signs, structural bolts, turnbuckle safeties, thimbles, guy-wire markers, shackles, safety wire, cathodic protection systems, stainless-steel cotter pins, coax cable hangers, grounding specifications for guy wires and anchor points, perimeter fence dimensions, and unused antennas and equipment to be removed. The government responded that towers must be inspected in accordance with relative Unified Facilities Criteria (UFC) code specific to structure type, including TIA-222 for guyed towers. The government stated that contractors are responsible for verifying quantities, sizing, and other specifications during their site visit.

View the file

Other files

File Type Posted
Questions and Answers_as of 13 AUG 26.pdf PDF
SF1449_W51AA126QA079.pdf PDF
Atch 3 - Site Visit.pdf PDF
Atch 1 - PWS.pdf PDF
Atch 2 - Pricing Sheet.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

QUESTIONS&ANSWERS–(asofAugust6,2026)
W51AA1-26-Q-A079TowerInspectionandMaintenance
RECEIVEDQUESTION/CONCERNGOVERNMENTRESPONSE

8/5/2026

To accurately price the material por on of CLIN 0003, please provide the quan es, sizes, specifica ons, or exis ng condi on details for the following PWS requirements:

LMR Tower

• 5.1.1.1 – Quan ty and specifica ons of RF radia on and/or high-voltage warning signs.

Building 32 Pla orm

• 5.1.2.1 – Quan ty and sizes of structural bolts to be replaced.

• 5.1.2.2 – Quan ty and specifica ons of RF radia on and/or high-voltage warning signs.

100 Ft Tower Track Tower

• 5.1.4.1 – Quan ty and specifica ons for the turnbuckle safe es.

• 5.1.4.2 – Quan ty and sizes of the new thimbles.

• 5.1.4.3 – Quan ty and specifica ons of the warning signs.

• 5.1.4.4 – Number of anchors and required length/size of the yellow guy-wire markers.

• 5.1.4.6 – Quan ty and sizes of the guy wires and preforms, and clarifica on of the required slipping and shank-adjustment work.

330 Ft Tower

• 5.1.5.1 – Number of shackles/anchor points requiring safety wire.

• 5.1.5.2 – Quan ty and specifica ons of the warning signs.

• 5.1.5.3 – Number of anchors and required type/size of cathodic protec on.

• 5.1.5.5 – Quan ty and sizes of stainless-steel co er pins.

• 5.1.5.8 – Quan ty and size/type of coax requiring hangers.

• 5.1.5.9 – Quan ty and specifica ons for guy-wire grounding.

• 5.1.5.10 – Quan ty and specifica ons for anchor-head grounding.

• 5.1.5.11 – Quan ty and specifica ons for anchor-sha grounding.

• 5.1.5.12 – Perimeter-fence dimensions and grounding specifica ons.

• 5.1.5.13 – Quan ty and sizes/types of unused antennas, coax, and mounts to be removed.

Tower are to be inspected in accordance with rela ve Unified Facili es Criteria (UFC) code for the respec ve type of structure. That includes TIA-222 for guyed towers. Contractors are to verify quan es, sizing, etc as part of their site visit.