DESCRIPTION:

TITLE:

NEWBURGH, NEW YORKSTEWART AIRPORT

AIR NATIONAL GUARD FACILITIES

DWG. NO:

BASE CIVIL ENGINEER:

DATE:

ENG:

CHK:

DR:

BY:DESCRIPTION:DATE:REV.:

OF:SHEET:SCALE:

07/15/2021

FAUSTO PLAZA

2ND LT. MICHAEL A. LYNCH NOTE:

THIS IS A SCHEMATIC REPRESENTATION OF

THE DESIRED END PRODUCT ONLY.

CONTRACTOR TO ABIDE TO ALL GOVERNING

CODES.

AREA OF

WORK

SCALE: 1" = 150'

SCALE : 1" = 100'

ENLARGED WORK AREA

FACILITY 205 & 206 FENCE REPAIR

41AS NOTED

ATTACHMENT 1

FACILITY 205 & 206

FENCE REPAIR & PRIVACY SLATS

AutoCAD SHX Text

EXISTING GATE

AutoCAD SHX Text

EXISTING GATE

AutoCAD SHX Text

EXISTING FENCE.

AutoCAD SHX Text (Gov. Use Only)

DESCRIPTION:

TITLE:

NEWBURGH, NEW YORKSTEWART AIRPORT

AIR NATIONAL GUARD FACILITIES

DWG. NO:

BASE CIVIL ENGINEER:

DATE:

ENG:

CHK:

DR:

BY:DESCRIPTION:DATE:REV.:

OF:SHEET:SCALE:

04/29/2021

FAUSTO PLAZA

2ND LT. MICHAEL A. LYNCH

42NTS

ATTACHMENT 2

FOUNDATION DETAIL

FENCE POST -

NOTE:

THIS IS A SCHEMATIC REPRESENTATION OF

THE DESIRED END PRODUCT ONLY.

CONTRACTOR TO ABIDE TO ALL GOVERNING

CODES.

NOT TO SCALE

FOUNDATION DETAIL

AutoCAD SHX Text

FENCE

AutoCAD SHX Text

POST

AutoCAD SHX Text

EXISTING GRADE. OUTSIDE FENCE AREA.

AutoCAD SHX Text

FOUNDATION DIAMETER = POST DIAMETER + 6"

R

T

K

PROPOSED

NEW FENCE

APPROXIMATELY

450 LF. (V.I.F)

EXIST. FENCE

EXIST. GATE

ACCESS

CONTROL

FACILITY

DESCRIPTION:

TITLE:

NEWBURGH, NEW YORKSTEWART AIRPORT

AIR NATIONAL GUARD FACILITIES

DWG. NO:

BASE CIVIL ENGINEER:

DATE:

ENG:

CHK:

DR:

BY:DESCRIPTION:DATE:REV.:

OF:SHEET:SCALE:

04/29/2021

FAUSTO PLAZA

2ND LT. MICHAEL A. LYNCH

431"=150'

ATTACHMENT 3

NEW FENCE

ACCESS CONTROL FACILITY

NOTE:

THIS IS A SCHEMATIC REPRESENTATION OF

THE DESIRED END PRODUCT ONLY.

CONTRACTOR TO ABIDE TO ALL GOVERNING

CODES.

ACCESS CONTROL FACILITY - NEW FENCE

ABBREVIATION

V.I.F VERIFY IN FIELD

TYP. TYPICAL

SCALE: 1"=150'

T

K

ACCESS

CONTROL

FACILITY

T

U

S

K

E

G

E

O

A

D

M

A

G

U

I

W

A

Y

INSTALL

NEW PRIVACY SLATS

ON EXISTING FENCE

APPROXIMATELY

620 LF. (V.I.F)

T

U

S

K

E

G

O

A

D

EXIST. FENCE

REMOVE CORNER POST

AND RE-ROUTE FENCE

TO THE NEXT POST

BOTH WAYS

PRIVACY SLATS

STARTING POINT

PRIVACY SLATS

END POINT

AREA OF

WORK

DESCRIPTION:

TITLE:

NEWBURGH, NEW YORKSTEWART AIRPORT

AIR NATIONAL GUARD FACILITIES

DWG. NO:

BASE CIVIL ENGINEER:

DATE:

ENG:

CHK:

DR:

BY:DESCRIPTION:DATE:REV.:

OF:SHEET:SCALE:

04/29/2021

FAUSTO PLAZA

2ND LT. MICHAEL A. LYNCH

44AS NOTED

ATTACHMENT 4

NEW PRIVACY SLATS

BLDG. 108

NOTE:

THIS IS A SCHEMATIC REPRESENTATION OF

THE DESIRED END PRODUCT ONLY.

CONTRACTOR TO ABIDE TO ALL GOVERNING

CODES.

NOT TO SCALE

BLDG. 108 NEW PRIVACY SLATS

MAGNIFIED AREA OF WORK

SCALE: 1"=100'

ABBREVIATION

V.I.F VERIFY IN FIELD

TYP. TYPICAL

Sheets and Views
WHAY210012 - Fence Project Rev1.1-205-206 PRIV FENCE
WHAY210012 - Fence Project Rev1.1-205-206 FOUND. DETAIL
WHAY210012 - Fence Project Rev1.1-F.GATE-FENCE
WHAY210012 - Fence Project Rev1.1-BLDG.108 FENCE

File details come from the government source that posted it. Updated .