PRQE_072247 2019 Project Elec_Mech_Plumb_Asbuilts_20260804.pdf

PDF 3 MB Posted

Attached to
B44 Breakroom Remodel
Solicitation number
W50S7X-26-Q-0008
Issued by

About this file

These are record drawings for Building 44 repair work at McConnell Air Force Base, prepared by the architecture firm GLM/V. The document set consists of five detailed plans for the first floor: a Mechanical HVAC Plan (MH101), a Mechanical Piping Plan (MP101), an Electrical Interior First Floor Lighting Plan (EL101), an Electrical Interior First Floor Power Plan (EP101), and an Electrical Interior First Floor Systems Plan (ET101). All plans are drawn at a scale of 1/8" = 1'-0" and are associated with Project PRQE 072247, Project No. 12094.020.

The HVAC plan indicates a complex mechanical system with multiple air handling units, ductwork distribution, and temperature control systems throughout the building. The piping plan shows water supply lines, drainage systems, and connections to mechanical equipment including water meters and supply shut-off provisions. The electrical plans detail lighting circuits with multiple fixtures distributed across numerous rooms, comprehensive power distribution to equipment and outlets, and systems integration including fire alarm, telecommunications, and emergency notification infrastructure. Plan notes throughout the drawings specify construction requirements such as securing mechanical systems, proper duct sizing, penetration sealing, and compliance with existing building infrastructure. These record drawings serve as documentation of the completed repair work and as-built conditions for Building 44 at McConnell AFB.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Check by:

Scale:

Sheet No.

Sheet:

Date:

Sheet Name:

Drawn by:

Chief Designer:

12094.020

Revisions:

Project No.

PROJECT NAME:

PRQE 072247

McConnell AFB

KANG

REPAIR

BUILDING 44

FOR CACS

F I G H T I NG JAY H AW KS

E . D ou gl as W ic hi ta , K

S

1T el

6)

5-

F ax

6)

-5 w w w .g lm v.

co m

A rc hi te ct ur e

R

EC

O R

D D

R A

W

IN

G S

MECHANICAL HVAC

PLAN - FIRST FLOOR

MH1010' 4' 8' 12'

1/8"=1'-0"

MECHANICAL HVAC PLAN - FIRST FLOOR

AutoCAD SHX Text

UP

AutoCAD SHX Text 12x14

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text RELOCATED (E)14X14 RA GRILLE. ROUTE NEW 12x14 DUCT TO GRILLE WITH A MINIMUM OF FOUR ELBOWS, AND DUCT LINER (FOR ACOUSTICAL MINIMUM OF FOUR ELBOWS, AND DUCT LINER (FOR ACOUSTICAL OF FOUR ELBOWS, AND DUCT LINER (FOR ACOUSTICAL PURPOSES). INSTALL SECURITY BARS IN WALL/FLOOR PENETRATION WITH AN ACCESS DOOR ON SECURE SIDE OF PERIMETER FOR VISUAL INSPECTIONS, PER ICS 705 REQUIREMENTS. INSTALL 6" NON-METALLIC FLEXIBLE CONNECTION IN DUCTWORK ON THE SECURE SIDE OF THE PERIMETER WITHIN 6" OF THE WALL/FLOOR, PER ICS-705 REQUIREMENTS. SEE 4/M-501. PENETRATION HAS EXISTING SECURITY BARS. INSTALL 6" NON-METALLIC FLEXIBLE CONNECTION WITHIN 6" OF THE WALL ON THE SECURE SIDE OF THE WALL, PER ICS-705 REQUIREMENTS. BALANCE EXISTING SUPPLY AIR DIFFUSER TO INDICATED CFM. (E)VVR-5 TO VVR-5 TO TO MAINTAIN 1400 CFM TOTAL FLOW. INSTALL NEW THERMOSTAT IN COMMUNICATIONS ROOM. (E)VVR-5 TO BE (E)VVR-5 TO BE TO BE CONTROLLED BY AVERAGE OF BOTH NEW AND EXISTING THERMOSTATS. SEE TEMPERATURE CONTROLS (MI102) FOR MORE INFORMATION. CONNECT EXISTING BRANCH DUCTWORK SERVING CHASE TO NEW 10x10 DUCT. INSTALL BALANCING DAMPER AND BALANCE TO 50 CFM. EMERGENCY HVAC SHUT-DOWN SWITCH. STRUCTURE IN THIS AREA IS UNDERGOING MODIFICATION. VERIFY EXISTING DUCTWORK WILL COORDINATE WITH STRUCTURAL MODIFICATIONS. BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT AS SOON AS POSSIBLE. DUCTS CONTINUE ON MH102 AT MEZZANINE LEVEL. COORDINATE DUCTS WITH STRUCTURAL ELEMENTS (BEAMS AND CROSS BRACING) AND FIRST FLOOR CEILING. INSTALL 6" NON-METALLIC FLEXIBLE CONNECTION WITHIN 6" OF THE WALL ON THE SECURE SIDE OF THE WALL, PER ICS-705 REQUIREMENTS. CLASS 1A, LOW-LEAK MOTORIZED DAMPER.

AutoCAD SHX Text

PLAN NOTES:

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text T

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text A

AutoCAD SHX Text 10x10

AutoCAD SHX Text

AutoCAD SHX Text (E)

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text (E)

AutoCAD SHX Text 16x16

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text (E)14x12

AutoCAD SHX Text

%%UBCU-2

AutoCAD SHX Text 10x10

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text 12x10

AutoCAD SHX Text 9"%%C

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text T

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text PERIMETER OF SECURED AREA. ALL OPENINGS AROUND EXISTING DUCTS AND PIPING THAT PENETRATE THE SECURE AREA PERIMETER SHALL HAVE 6" OF NON-METALLIC FLEX CONNECTIONS (FOR DUCTS) AND FLEX RUBBER SEALANT (FOR PIPING) TO CREATE A DIELECTRIC UNION. ALL DUCTS 96" SQUARE INCHES AND LARGER. THAT PENETRATE THE SECURE AREA PERIMETER SHALL HAVE SECURITY BARS AND AN ACCESS DOOR ON THE SECURE SIDE FOR VISUAL INSPECTIONS. SEE DETAIL 4/M-501. THE DRAWINGS DO NOT INDICATE ALL EXISTING DUCTS AND PIPING THAT PENETRATE THE SECURE AREA. THE CONTRACTOR SHALL FIELD VERIFY ALL PENETRATIONS AND PROVIDE 6" OF NON-METALLIC FLEX CONNECTORS AND SECURITY BARS/ACCESS DOORS (FOR ALL DUCTS) AND FLEX RUBBER SEALANT (FOR ALL PIPING) THAT PENETRATE THE SECURE AREA AS REQUIRED. THE CONTRACTOR SHALL INDICATE ALL EXISTING PENETRATIONS ON THE AS-BUILT DRAWINGS.

AutoCAD SHX Text 22x10

AutoCAD SHX Text 22x10

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text

OPERATIONS

AutoCAD SHX Text

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

AutoCAD SHX Text

AREA

AutoCAD SHX Text

LOCKER

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

HALLWAY

AutoCAD SHX Text

COSA

AutoCAD SHX Text 102A

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

SQ ADMIN

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

1ST SGT.

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

CONFERENCE

AutoCAD SHX Text

AutoCAD SHX Text

OPERATIONS

AutoCAD SHX Text

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

COMM.

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

SSO

AutoCAD SHX Text

AutoCAD SHX Text

STAN/EVAL

AutoCAD SHX Text

AutoCAD SHX Text W & T

AutoCAD SHX Text

TRAINING/

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

AutoCAD SHX Text

MEN

AutoCAD SHX Text

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text

AutoCAD SHX Text J.C.

AutoCAD SHX Text 102B

AutoCAD SHX Text

BREAKROOM

AutoCAD SHX Text

WORKSPACE/

AutoCAD SHX Text

AutoCAD SHX Text

ACCESS

AutoCAD SHX Text

HALL

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

AutoCAD SHX Text

COMMANDER

AutoCAD SHX Text 109A

AutoCAD SHX Text

%%UBCU-4

AutoCAD SHX Text

%%UBCU-3

AutoCAD SHX Text

%%UBCU-5

AutoCAD SHX Text

%%UBCU-7

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text

%%UBCU-8

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text 9x9

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text 9x9

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

%%UERV-1

AutoCAD SHX Text

(E)EXHAUST LOUVER

AutoCAD SHX Text

%%U(E)VVR-1

AutoCAD SHX Text

%%U(E)VVR-2

AutoCAD SHX Text

%%U(E)VVR-3

AutoCAD SHX Text

%%U(E)VVR-6

AutoCAD SHX Text

%%U(E)VVR-5

AutoCAD SHX Text

%%U(E)VVR-4

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text (E)12"%%C

AutoCAD SHX Text (E)34x18

AutoCAD SHX Text (E)18x18

AutoCAD SHX Text (E)18x12

AutoCAD SHX Text (E)34x18

AutoCAD SHX Text (E)18x18

AutoCAD SHX Text (E)16"%%C

AutoCAD SHX Text (E)34x18

AutoCAD SHX Text (E)18x18

AutoCAD SHX Text (E)16"%%C

AutoCAD SHX Text (E)14"%%C

AutoCAD SHX Text (E)10"%%C

AutoCAD SHX Text (E)24x18

AutoCAD SHX Text (E)24x16

AutoCAD SHX Text (E)9"%%C

AutoCAD SHX Text (E)6"%%C

AutoCAD SHX Text (E)16'%%C

AutoCAD SHX Text (E)30x16

AutoCAD SHX Text (E)12x12

AutoCAD SHX Text (E)9"%%C

AutoCAD SHX Text (E)48x48 INTAKE

AutoCAD SHX Text

LOUVER (%%UL-4)

AutoCAD SHX Text (E)24x60 RA TO BELOW RAISED FLOOR & UP TO MEZZ

AutoCAD SHX Text (E)-48x84

AutoCAD SHX Text (E)20x12

AutoCAD SHX Text (E)10"%%C

AutoCAD SHX Text T

AutoCAD SHX Text H

AutoCAD SHX Text

(E)EF

AutoCAD SHX Text (E)48x16

AutoCAD SHX Text

EXIST. LOUVER

AutoCAD SHX Text

TO REMAIN.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text 9x9

AutoCAD SHX Text

AutoCAD SHX Text

%%UUH-1

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text

AutoCAD SHX Text

%%UBCU-6

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text 9x9

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text 12x12

AutoCAD SHX Text

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text 22x10

AutoCAD SHX Text T

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text NOTE: INSTALL FLEX CONNECTIONS ON SUPPLY AND RETURN DUCT CONNECTIONS AT ALL BLOWER COIL UNITS. RETURN DUCTWORK SHALL BE INTERNALLY LINED. (TYP. ALL BCU.)

AutoCAD SHX Text NOTE: CLIN 1 - NO MECHANICAL WORK THIS SHEET. CLIN 2 - ALL MECHANICAL WORK THIS SHEET.

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

VTC

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXTERNALLY WRAP EXISTING EXHAUST

AutoCAD SHX Text

PLENUM & ONE FOOT PAST DAMPER

AutoCAD SHX Text

WITH 1" THICK FIBERGLASS INSULATION.

AutoCAD SHX Text INSTALL CLASS 1A, LOW-LEAK MOTORIZED DAMPER IN EXHAUST. WIRE TO OPEN UPON FAN OPERATION.

AutoCAD SHX Text 46x20

AutoCAD SHX Text 46x20

AutoCAD SHX Text A

AutoCAD SHX Text 15x15

AutoCAD SHX Text

AutoCAD SHX Text

TYP. 15

AutoCAD SHX Text C

AutoCAD SHX Text 22x22

AutoCAD SHX Text C

AutoCAD SHX Text 22x22

AutoCAD SHX Text C

AutoCAD SHX Text 22x22

AutoCAD SHX Text C

AutoCAD SHX Text 22x22

AutoCAD SHX Text C

AutoCAD SHX Text 22x22

AutoCAD SHX Text C

AutoCAD SHX Text 22x22

AutoCAD SHX Text 20x16

AutoCAD SHX Text 16x14

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 26x16

AutoCAD SHX Text 20x14

AutoCAD SHX Text 14x14

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 22x16

AutoCAD SHX Text 26x16

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text T

AutoCAD SHX Text PLENUM SPACE IS TIGHT IN OPERATIONS 119. AVOID ROUTING DUCTS OVER LIGHT FIXTURES WHERE POSSIBLE.

AutoCAD SHX Text 42x20

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text NOTE: TEMPERATURE CONTROLS CONTRACTOR SHALL UPGRADE ALL EXISTING CONTROLS ON THE OLD SYSTEM TO MATCH THE NEW CONTROLS BEING INSTALLED. IT IS THE RESPONSIBILITY OF THE TCC TO DETERMINE ALL REQUIREMENTS AND UPDATE THE OBSOLETE CONTROLS AS REQUIRED.

AutoCAD SHX Text

BOTTOM OF DUCT SHALL

AutoCAD SHX Text

BE 1'-1 1/2" ABOVE MECH

AutoCAD SHX Text

BOTTOM OF DUCT

AutoCAD SHX Text

AT 1'-1 1/2" ABOVE

AutoCAD SHX Text

MECH MEZZ FLOOR

AutoCAD SHX Text

MEZZANINE FLOOR.

AutoCAD SHX Text 14"%%c

AutoCAD SHX Text 14"%%c

AutoCAD SHX Text 14"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 12"%%c

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text U:\Wichita-Facil\2011\11155\008\Mech\Drawings\As-Builts\MH101 MECHANICAL HVAC PLAN - FIRST FLOOR

AutoCAD SHX Text Saved 01-10-2019 4:29:09 PM by CWW01-10-2019 4:29:09 PM by CWW by CWWCWW

AutoCAD SHX Text

APR. 28, 2017

AutoCAD SHX Text

OF 66

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text 184th CES

AutoCAD SHX Text Kansas Air National Guard

AutoCAD SHX Text McConnell AFB Wichita KS

AutoCAD SHX Text THESE DOCUMENTS INCLUDE RECORD INFORMATION PROVIDED BY THE CONTRACTOR. THIS INFORMATION HAS NOT BEEN VERIFIED IN ITS ENTIRETY BY THE DESIGN PROFESSIONAL. DATE: JANUARY 2019

AutoCAD SHX Text

CWW

AutoCAD SHX Text

MHN

AutoCAD SHX Text

CWW

AutoCAD SHX Text

Sheet No.

Sheet:

Date:

Sheet Name:

Drawn by:

Chief Designer:

12094.020

Revisions:

Project No.

PROJECT NAME:

PRQE 072247

McConnell AFB

KANG

REPAIR

BUILDING 44

FOR CACS

F I G H T I NG JAY H AW KS

E . D ou gl as W ic hi ta , K

S

1T el

6)

5-

F ax

6)

-5 w w w .g lm v.

co m

A rc hi te ct ur e

R

EC

O R

D D

R A

W

IN

G S

MECHANICAL PIPING

PLAN - FIRST FLOOR

MP101

0' 4' 8' 12'

1/8"=1'-0"

MECHANICAL PIPING PLAN - FIRST FLOOR

AutoCAD SHX Text

UP

AutoCAD SHX Text

%%U(E)VVR-1

AutoCAD SHX Text

%%U(E)VVR-2

AutoCAD SHX Text

%%U(E)VVR-3

AutoCAD SHX Text

%%U(E)VVR-6

AutoCAD SHX Text

%%U(E)VVR-5

AutoCAD SHX Text

%%U(E)VVR-4

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text

(E)1"HWS/R

AutoCAD SHX Text

(E)1-1/4"HWS/R

AutoCAD SHX Text

(E)1"HWS/R

AutoCAD SHX Text

(E)1-1/2"HWS/R

AutoCAD SHX Text

(E)2"HWR/S

AutoCAD SHX Text

(E)1"HWR/S

AutoCAD SHX Text

%%U(E)CP-1 & 2

AutoCAD SHX Text

TO CHILLER

AutoCAD SHX Text

(E)2"HWS/R UP

AutoCAD SHX Text oo

AutoCAD SHX Text

(E)UNIT HEATER

AutoCAD SHX Text

(E)3/4"HWS/R UP

AutoCAD SHX Text

(E)1/2"CD TO EXIST FD

AutoCAD SHX Text

(E)FD'S

AutoCAD SHX Text

%%U(E)CWP-1 & 2

AutoCAD SHX Text

(E)6"CWS/R

AutoCAD SHX Text

(E)6"CWS/R

AutoCAD SHX Text

FARM

AutoCAD SHX Text

%%U(E)BR-2

AutoCAD SHX Text

%%U(E)BR-1

AutoCAD SHX Text

(E)FD (TYP.)

AutoCAD SHX Text

(E)GLYCOL MAKE-UP TANK

AutoCAD SHX Text

(E)RO EQUIPMENT

AutoCAD SHX Text

(E)FP

AutoCAD SHX Text

(E)DCW

AutoCAD SHX Text

(E)DCW

AutoCAD SHX Text

HWR

AutoCAD SHX Text

HWR

AutoCAD SHX Text

HWR

AutoCAD SHX Text

HWS

AutoCAD SHX Text

HWS

AutoCAD SHX Text

HWS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text FLOOR PATCHED WHERE ABANDONED PIPING WAS REMOVED. SEAL AROUND PIPE PENETRATIONS WITH RUBBER SPRAY FOAM INSULATION PER ICS-705 REQUIREMENTS. ROUTE CONDENSATE DRAIN DOWN WALL TO TERMINATE AT MOP SINK OR NEAREST FLOOR DRAIN WITH AIR GAP. RACK 2-1/2" HWS/R, 3" CWS/R, & FP PIPING ON WALL AND CONNECT TO EXISTING PENETRATIONS THRU WALLS. CONNECT NEW PIPING TO EXISTING RISER THRU TO SECOND FLOOR MEZZANINE. REINSULATE EXISTING AIR SEPARATOR IN THE SOUTH MECHANICAL ROOM. ELEVATOR PIT SUMP PUMP DISCHARGE. REPLACE EXISTING GAS METER AND (2) WATER METERS. REF DETAIL 4/MI101 FOR CONTROLS. ADD HWR THERMOMETER AND TEMP SENSOR TO DDC SYSTEM. EXTEND 3/4" HWS/R TO UNIT HEATER. PIPING SHALL BE SIMILAR TO 8/M-501. PROVIDE DIFFERENTIAL PRESSURE SENSORS ON TOP OF PIPING AND PROVIDE BLOWDOWN VALVES. - REFER TO TEMPERATURE CONTROLS.

AutoCAD SHX Text

PLAN NOTES:

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

3"HWS/R UP TO MEZZANINE

AutoCAD SHX Text

(TYP. 2)

AutoCAD SHX Text (E)2"G

AutoCAD SHX Text

(E)3/4"HWS/R

AutoCAD SHX Text T

AutoCAD SHX Text

3/4"CWS/R

AutoCAD SHX Text

3/4"HWS/R

AutoCAD SHX Text

CO

AutoCAD SHX Text

AutoCAD SHX Text

1"CD

AutoCAD SHX Text

%%UBCU-2

AutoCAD SHX Text PERIMETER OF SECURED AREA. ALL OPENINGS AROUND EXISTING DUCTS AND PIPING THAT PENETRATE THE SECURE AREA PERIMETER SHALL HAVE 6" OF NON-METALLIC FLEX CONNECTIONS (FOR DUCTS) AND FLEX RUBBER SEALANT (FOR PIPING) TO CREATE A DIELECTRIC UNION. ALL DUCTS 96" SQUARE INCHES AND LARGER THAT PENETRATE THE SECURE AREA PERIMETER SHALL HAVE SECURITY BARS AND AN ACCESS DOOR ON THE SECURE SIDE FOR VISUAL INSPECTIONS. SEE DETAIL 4/M-501. THE DRAWINGS DO NOT INDICATE ALL EXISTING DUCTS AND PIPING THAT PENETRATE THE SECURE AREA. THE CONTRACTOR SHALL FIELD VERIFY ALL PENETRATIONS AND PROVIDE 6" OF NON-METALLIC FLEX CONNECTORS AND SECURITY BARS/ACCESS DOORS (FOR ALL DUCTS) AND FLEX RUBBER SEALANT (FOR ALL PIPING) THAT PENETRATE THE SECURE AREA AS REQUIRED. THE CONTRACTOR SHALL INDICATE ALL EXISTING PENETRATIONS ON THE AS-BUILT DRAWINGS.

AutoCAD SHX Text

TYP.

AutoCAD SHX Text

OPERATIONS

AutoCAD SHX Text

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

AutoCAD SHX Text

AREA

AutoCAD SHX Text

LOCKER

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

HALLWAY

AutoCAD SHX Text

COSA

AutoCAD SHX Text 102A

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

SQ ADMIN

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

1ST SGT.

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

CONFERENCE

AutoCAD SHX Text

AutoCAD SHX Text

OPERATIONS

AutoCAD SHX Text

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

COMM.

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

VTC

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

SSO

AutoCAD SHX Text

AutoCAD SHX Text

STAN/EVAL

AutoCAD SHX Text

AutoCAD SHX Text W & T

AutoCAD SHX Text

TRAINING/

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

AutoCAD SHX Text

MEN

AutoCAD SHX Text

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text

AutoCAD SHX Text J.C.

AutoCAD SHX Text 102B

AutoCAD SHX Text

BREAKROOM

AutoCAD SHX Text

WORKSPACE/

AutoCAD SHX Text

AutoCAD SHX Text

ACCESS

AutoCAD SHX Text

HALL

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

AutoCAD SHX Text

COMMANDER

AutoCAD SHX Text 109A

AutoCAD SHX Text

%%UBCU-4

AutoCAD SHX Text

%%UBCU-3

AutoCAD SHX Text

%%UBCU-5

AutoCAD SHX Text

%%UBCU-7

AutoCAD SHX Text

%%UBCU-6

AutoCAD SHX Text

%%UBCU-8

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ISOLATION VALVES (TYP)

AutoCAD SHX Text

AutoCAD SHX Text

CO

AutoCAD SHX Text

CO

AutoCAD SHX Text

1-1/4"CD

AutoCAD SHX Text

1-1/4"CD

AutoCAD SHX Text

1-1/4" HWS/R

AutoCAD SHX Text

2" CWS/R

AutoCAD SHX Text

%%USP-1

AutoCAD SHX Text

TYP.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NEW GAS METER

AutoCAD SHX Text

%%UUH-1

AutoCAD SHX Text

ELECTRICAL EQUIPMENT.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CO

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

1" HWS/R

AutoCAD SHX Text

1" CWS/R

AutoCAD SHX Text

1-1/4" HWS/R

AutoCAD SHX Text

1-1/2" CWS/R

AutoCAD SHX Text

CO

AutoCAD SHX Text

NOTE: APPLY RUBBER SEALANT AROUND

AutoCAD SHX Text

ALL PENETRATIONS THRU THE CEILING

AutoCAD SHX Text

OF ROOMS 115, 117, & 121.

AutoCAD SHX Text

NEW WATER METER

AutoCAD SHX Text

AutoCAD SHX Text NOTE: CLIN 1 - NO MECHANICAL WORK THIS SHEET. CLIN 2 - ALL MECHANICAL WORK THIS SHEET.

AutoCAD SHX Text

ROUTE CONDENSATE DOWN IN

AutoCAD SHX Text

WALL AND SPILL ONTO GRADE.

AutoCAD SHX Text

PROVIDE ESCUTCHEON AT WALL

AutoCAD SHX Text

PENETRATION AND TURN PIPING

AutoCAD SHX Text

DOWN AT 45%%D ANGLE.

AutoCAD SHX Text

1-1/4"CD

AutoCAD SHX Text

1-1/4"CD UP

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text NOTE: TEMPERATURE CONTROLS CONTRACTOR SHALL UPGRADE ALL EXISTING CONTROLS ON THE OLD SYSTEM TO MATCH THE NEW CONTROLS BEING INSTALLED. IT IS THE RESPONSIBILITY OF THE TCC TO DETERMINE ALL REQUIREMENTS AND UPDATE THE OBSOLETE CONTROLS AS REQUIRED.

AutoCAD SHX Text U:\Wichita-Facil\2011\11155\008\Mech\Drawings\As-Builts\MP101 MECHANICAL PIPING PLAN - FIRST FLOOR

AutoCAD SHX Text Saved 01-10-2019 10:00:02 AM by MHN01-10-2019 10:00:02 AM by MHN by MHNMHN

AutoCAD SHX Text

APR. 28, 2017

AutoCAD SHX Text

OF 66

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text 184th CES

AutoCAD SHX Text Kansas Air National Guard

AutoCAD SHX Text McConnell AFB Wichita KS

AutoCAD SHX Text THESE DOCUMENTS INCLUDE RECORD INFORMATION PROVIDED BY THE CONTRACTOR. THIS INFORMATION HAS NOT BEEN VERIFIED IN ITS ENTIRETY BY THE DESIGN PROFESSIONAL. DATE: JANUARY 2019

AutoCAD SHX Text

CWW

AutoCAD SHX Text

MHN

AutoCAD SHX Text

CWW

Sheet No.

Sheet:

Date:

Sheet Name:

Drawn by:

Chief Designer:

12094.020

Revisions:

Project No.

PROJECT NAME:

PRQE 072247

McConnell AFB

KANG

REPAIR

BUILDING 44

FOR CACS

F I G H T I NG JAY H AW KS

E

D o u g l a s

W i c h i t a

K

S

T e l

F a x w w w g l m v c o m

A rc hi te ct ur e

R E

C O

R D

A

W I N

G S

ELECTRICAL INTERIOR

FIRST FLOOR LIGHTING

PLAN

EL101

AutoCAD SHX Text S3E

AutoCAD SHX Text

OPERATIONS

AutoCAD SHX Text

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

AutoCAD SHX Text

AREA

AutoCAD SHX Text

LOCKER

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

HALLWAY

AutoCAD SHX Text

COSA

AutoCAD SHX Text 102A

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

SQ ADMIN

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

1ST SGT.

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

CONFERENCE

AutoCAD SHX Text

AutoCAD SHX Text

OPERATIONS

AutoCAD SHX Text

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

COMM.

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

CONF

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

SSO

AutoCAD SHX Text

AutoCAD SHX Text

STAN/EVAL

AutoCAD SHX Text

AutoCAD SHX Text W & T

AutoCAD SHX Text

TRAINING/

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

AutoCAD SHX Text

MEN

AutoCAD SHX Text

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text

AutoCAD SHX Text J.C.

AutoCAD SHX Text 102B

AutoCAD SHX Text

BREAKROOM

AutoCAD SHX Text

WORKSPACE/

AutoCAD SHX Text

AutoCAD SHX Text

ACCESS

AutoCAD SHX Text

HALL

AutoCAD SHX Text

AutoCAD SHX Text

COMMANDER

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

AutoCAD SHX Text

UP

AutoCAD SHX Text

ELECTRICAL INTERIOR FIRST FLOOR LIGHTING PLAN

AutoCAD SHX Text N

AutoCAD SHX Text 12'

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 0'

AutoCAD SHX Text 20'

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text A

AutoCAD SHX Text

%%UKEYED NOTES:

AutoCAD SHX Text

1. RELOCATED EXISTING LIGHT FIXTURE/SWITCH. RE-CONNECT TO EXISTING RELOCATED EXISTING LIGHT FIXTURE/SWITCH. RE-CONNECT TO EXISTING CIRCUITING AND SWITCHING. 2. CONNECT TO EXISTING LIGHTING CIRCUIT IN THIS AREA. UPDATE PANEL CONNECT TO EXISTING LIGHTING CIRCUIT IN THIS AREA. UPDATE PANEL SCHEDULE ACCORDINGLY. 3. CONNECT TO EXISTING LIGHTING CIRCUIT MADE SPARE BY DEMOLITION. CONNECT TO EXISTING LIGHTING CIRCUIT MADE SPARE BY DEMOLITION. UPDATE PANEL SCHEDULE ACCORDINGLY. 4. EXISTING SIGNAL LIGHTS AND ASSOCIATED SWITCHING SHALL BE ALTERED EXISTING SIGNAL LIGHTS AND ASSOCIATED SWITCHING SHALL BE ALTERED SUCH THAT ONLY THE BLUE SIGNAL LIGHT IS OPERATIONAL. OTHER SIGNAL LIGHTS SHALL BE REMOVED. 5. NOT USED. NOT USED. 6. MOUNT ABOVE DOOR. CONNECT TO EXISTING EXTERIOR LIGHTING CIRCUIT MOUNT ABOVE DOOR. CONNECT TO EXISTING EXTERIOR LIGHTING CIRCUIT AND CONTROLS. 7. NOT USED. NOT USED. 8. WORK IN THIS ROOM IS PRIORITY ONE TO ALLOW EXISTING WORK IN THIS ROOM IS PRIORITY ONE TO ALLOW EXISTING COMMUNICATIONS ROOM TO BE DEACTIVATED. 9. SURFACE MOUNTED SWITCH. RECONNECT TO EXISTING SURFACE MOUNTED SWITCH. RECONNECT TO EXISTING SWITCHING/CIRCUITING IN AREA. 10. INTERLOCK OCCUPANCY SENSORS AS REQUIRED. INTERLOCK OCCUPANCY SENSORS AS REQUIRED. 11. MOUNT IN PIT. REFER TO DETAIL 1/E-504. MOUNT IN PIT. REFER TO DETAIL 1/E-504. 12. CONDUIT AND OUTLET BOX SHALL BE SURFACE MOUNTED.CONDUIT AND OUTLET BOX SHALL BE SURFACE MOUNTED.

AutoCAD SHX Text

AutoCAD SHX Text %%uPLAN NOTES:%%u

AutoCAD SHX Text

1. BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME RUNS WITH BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME RUNS WITH INDIVIDUAL NEUTRALS. A MAXIMUM OF THREE CIRCUITS (MAXIMUM OF THREE PHASE CONDUCTORS) MAY BE GROUPED IN A SINGLE CONDUIT. WHERE MULTIPLE CIRCUITS ARE LOCATED IN THE SAME RACEWAY, JUNCTION BOX OR ENCLOSURE, NEUTRALS SHALL BE MARKED OR LABELED TO INDICATE WHICH CIRCUIT THEY ARE ASSOCIATED WITH. SEE SPECIFICATION SECTION "LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES" FOR ADDITIONAL INFORMATION. 2. A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS REQUIRED IN A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS REQUIRED IN ALL CONDUITS. 3. ALL PENETRATIONS IN THE RATED AND STC WALLS AND CEILINGS SHALL ALL PENETRATIONS IN THE RATED AND STC WALLS AND CEILINGS SHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT GASSES. THE SEALANT SHALL HAVE A T-RATING OF ONE HOUR. 4. ALL PIPING, CONDUIT, AND OUTLET BOXES (ELECTRIC, TELEPHONE, ALL PIPING, CONDUIT, AND OUTLET BOXES (ELECTRIC, TELEPHONE, COMPUTER, ETC.) IN THE RATED WALLS OR CEILING AND STC WALLS SHALL BE CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL. 5. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LIGHT REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LIGHT FIXTURE LOCATIONS. VERIFY ALL DISCREPANCIES WITH ARCHITECT PRIOR TO ROUGH-IN.

AutoCAD SHX Text E

AutoCAD SHX Text S1

AutoCAD SHX Text a

AutoCAD SHX Text S1

AutoCAD SHX Text a

AutoCAD SHX Text %%uDP-2%%u

AutoCAD SHX Text %%uDP-1%%u

AutoCAD SHX Text %%uHS%%u

AutoCAD SHX Text %%uHMC%%u

AutoCAD SHX Text %%uTS-L1B%%u

AutoCAD SHX Text %%uTS-L1A%%u

AutoCAD SHX Text %%uL1A%%u

AutoCAD SHX Text %%uL1B%%u

AutoCAD SHX Text M

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text S4

AutoCAD SHX Text S3

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2E

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2E

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2E

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2E

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2E

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2E

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text S2E

AutoCAD SHX Text ALL WORK INDICATED ON THIS SHEET SHALL BE PART OF CLIN 002, EXCEPT FOR THE NEW LIGHT FIXTURES AND ASSOCIATED CABLING, CONDUIT, AND CONTROL IN ROOMS 123, 124 AND 126. THE REMOVAL OF THESE FIXTURES, INSTALLATION AND ASSOCIATED CABLING, CONDUIT AND CONTROL SHALL BE UNDER CLIN 002, BID OPTION 2.

AutoCAD SHX Text S4

AutoCAD SHX Text S

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text PERIMETER OF SECURE AREA. PENETRATIONS SHALL BE KEPT TO A MINIMUM. ALL METALLIC CONDUITS AND PIPING THAT PENETRATE THE SECURE AREA WALLS, FLOOR, OR CEILING SHALL HAVE FLEX RUBBER SEALANT INSTALLED COMPLETELY AROUND THE PIPE/CONDUIT TO CREATE THE DIELECTRIC UNION. ALL PENETRATIONS SHALL BE DOCUMENTED ON AS-BUILT DRAWINGS.

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

1605VA

AutoCAD SHX Text

AutoCAD SHX Text

9' CLG

AutoCAD SHX Text

9' CLG

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S5

AutoCAD SHX Text S5

AutoCAD SHX Text S5

AutoCAD SHX Text S5

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text S8

AutoCAD SHX Text b

AutoCAD SHX Text S8

AutoCAD SHX Text b

AutoCAD SHX Text S8E

AutoCAD SHX Text b

AutoCAD SHX Text S8

AutoCAD SHX Text b

AutoCAD SHX Text S8

AutoCAD SHX Text b

AutoCAD SHX Text S8

AutoCAD SHX Text b

AutoCAD SHX Text S8

AutoCAD SHX Text b

AutoCAD SHX Text S8E

AutoCAD SHX Text b

AutoCAD SHX Text S8

AutoCAD SHX Text b

AutoCAD SHX Text S8

AutoCAD SHX Text b

AutoCAD SHX Text S8

AutoCAD SHX Text b

AutoCAD SHX Text S8

AutoCAD SHX Text b

AutoCAD SHX Text S8

AutoCAD SHX Text b

AutoCAD SHX Text S8

AutoCAD SHX Text b

AutoCAD SHX Text S8

AutoCAD SHX Text b

AutoCAD SHX Text S8E

AutoCAD SHX Text b

AutoCAD SHX Text S8

AutoCAD SHX Text b

AutoCAD SHX Text S8E

AutoCAD SHX Text b

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text b

AutoCAD SHX Text c

AutoCAD SHX Text d

AutoCAD SHX Text b

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text S10

AutoCAD SHX Text c

AutoCAD SHX Text S10

AutoCAD SHX Text c

AutoCAD SHX Text S10

AutoCAD SHX Text c

AutoCAD SHX Text S10

AutoCAD SHX Text c

AutoCAD SHX Text S10

AutoCAD SHX Text c

AutoCAD SHX Text S10

AutoCAD SHX Text c

AutoCAD SHX Text S10

AutoCAD SHX Text c

AutoCAD SHX Text S10

AutoCAD SHX Text c

AutoCAD SHX Text S10

AutoCAD SHX Text c

AutoCAD SHX Text S10

AutoCAD SHX Text d

AutoCAD SHX Text S10

AutoCAD SHX Text d

AutoCAD SHX Text S10

AutoCAD SHX Text d

AutoCAD SHX Text S10

AutoCAD SHX Text d

AutoCAD SHX Text S10

AutoCAD SHX Text d

AutoCAD SHX Text S10

AutoCAD SHX Text e

AutoCAD SHX Text S10

AutoCAD SHX Text d

AutoCAD SHX Text S10

AutoCAD SHX Text d

AutoCAD SHX Text S10

AutoCAD SHX Text d

AutoCAD SHX Text S10

AutoCAD SHX Text d

AutoCAD SHX Text S10

AutoCAD SHX Text d

AutoCAD SHX Text S10

AutoCAD SHX Text e

AutoCAD SHX Text S10

AutoCAD SHX Text e

AutoCAD SHX Text S10

AutoCAD SHX Text e

AutoCAD SHX Text S10

AutoCAD SHX Text e

AutoCAD SHX Text S10

AutoCAD SHX Text e

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text D

AutoCAD SHX Text e

AutoCAD SHX Text S

AutoCAD SHX Text a

AutoCAD SHX Text S3

AutoCAD SHX Text 1260W

AutoCAD SHX Text 1565W

AutoCAD SHX Text

XA

AutoCAD SHX Text

XA

AutoCAD SHX Text TO SWITCH 'a'

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3E

AutoCAD SHX Text S3E

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S9

AutoCAD SHX Text S3

AutoCAD SHX Text S3E

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text S6

AutoCAD SHX Text D

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3

AutoCAD SHX Text S3E

AutoCAD SHX Text S3

AutoCAD SHX Text D

AutoCAD SHX Text

WL

AutoCAD SHX Text S4

AutoCAD SHX Text S4

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text %%uRU%%u

AutoCAD SHX Text %%uL2%%u

AutoCAD SHX Text

XA

AutoCAD SHX Text

XA

AutoCAD SHX Text

XA

AutoCAD SHX Text

XA

AutoCAD SHX Text

XA

AutoCAD SHX Text

XA

AutoCAD SHX Text L2:23

AutoCAD SHX Text S3E

AutoCAD SHX Text

NL

AutoCAD SHX Text S4

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

(TYP)

AutoCAD SHX Text S

AutoCAD SHX Text S7

AutoCAD SHX Text S7

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text L2:25

AutoCAD SHX Text

1290VA

AutoCAD SHX Text

800VA

AutoCAD SHX Text

AutoCAD SHX Text

LU:103

AutoCAD SHX Text

LU:105

AutoCAD SHX Text

LU:107

AutoCAD SHX Text %%uLU%%u

AutoCAD SHX Text 54"

AutoCAD SHX Text S6

AutoCAD SHX Text S

AutoCAD SHX Text S3

AutoCAD SHX Text S2

AutoCAD SHX Text S2

AutoCAD SHX Text U:\Wichita-Facil\2011\11155\008\Elec\Drawings\As-Builts\11155-008-EL101

AutoCAD SHX Text Saved 10-30-2018 1:47:36 PM by DANNY.MINKS10-30-2018 1:47:36 PM by DANNY.MINKS by DANNY.MINKSDANNY.MINKS

AutoCAD SHX Text

APR. 28, 2017

AutoCAD SHX Text

OF 66

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text 184th CES

AutoCAD SHX Text Kansas Air National Guard

AutoCAD SHX Text McConnell AFB Wichita KS

AutoCAD SHX Text THESE DOCUMENTS INCLUDE RECORD INFORMATION PROVIDED BY THE CONTRACTOR. THIS INFORMATION HAS NOT BEEN VERIFIED IN ITS ENTIRETY BY THE DESIGN PROFESSIONAL. DATE: OCTOBER 2018

AutoCAD SHX Text

JLM

AutoCAD SHX Text

JLM

AutoCAD SHX Text

SMS

Sheet No.

Sheet:

Date:

Sheet Name:

Drawn by:

Chief Designer:

12094.020

Revisions:

Project No.

PROJECT NAME:

PRQE 072247

McConnell AFB

KANG

REPAIR

BUILDING 44

FOR CACS

F I G H T I NG JAY H AW KS

D o u g l a s

W i c h i t a

K

S

T e l

F a x w w w g l m v c o m

A rc hi te ct ur e

R E

C O

A

W I N

G S

ELECTRICAL INTERIOR

FIRST FLOOR POWER PLAN

EP101

AutoCAD SHX Text

UP

AutoCAD SHX Text

ELECTRICAL INTERIOR FIRST FLOOR POWER PLAN

AutoCAD SHX Text N

AutoCAD SHX Text 12'

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 0'

AutoCAD SHX Text 20'

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text A

AutoCAD SHX Text

%%UKEYED NOTES:

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text 80"

AutoCAD SHX Text 80"

AutoCAD SHX Text J

AutoCAD SHX Text 80"

AutoCAD SHX Text 80"

AutoCAD SHX Text J

AutoCAD SHX Text 120"

AutoCAD SHX Text 120"

AutoCAD SHX Text J

AutoCAD SHX Text 80"

AutoCAD SHX Text 80"

AutoCAD SHX Text 48"

AutoCAD SHX Text J

AutoCAD SHX Text 36"

AutoCAD SHX Text 36"

AutoCAD SHX Text 120"

AutoCAD SHX Text 120"

AutoCAD SHX Text J

AutoCAD SHX Text 120"

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text 72"

AutoCAD SHX Text 72"

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text 72"

AutoCAD SHX Text 72"

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text 120"

AutoCAD SHX Text %%uPLAN NOTES:%%u

AutoCAD SHX Text

1. BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME RUNS WITH BRANCH CIRCUITS ARE INDICATED AS ONE CIRCUIT HOME RUNS WITH INDIVIDUAL NEUTRALS. A MAXIMUM OF THREE CIRCUITS (MAXIMUM OF THREE PHASE CONDUCTORS) MAY BE GROUPED IN A SINGLE CONDUIT. WHERE MULTIPLE CIRCUITS ARE LOCATED IN THE SAME RACEWAY, JUNCTION BOX OR ENCLOSURE, NEUTRALS SHALL BE MARKED OR LABELED TO INDICATE WHICH CIRCUIT THEY ARE ASSOCIATED WITH. SEE SPECIFICATION SECTION "LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES" FOR ADDITIONAL INFORMATION. 2. A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS REQUIRED IN A GROUND CONDUCTOR SIZED PER N.E.C. ARTICLE 250 IS REQUIRED IN ALL CONDUITS. 3. FOR CONNECTION REQUIREMENTS TO MECHANICAL UNITS, SEE FOR CONNECTION REQUIREMENTS TO MECHANICAL UNITS, SEE MECHANICAL EQUIPMENT CONNECTION SCHEDULE. 4. ALL PENETRATIONS IN THE RATED WALLS AND CEILINGS SHALL BE ALL PENETRATIONS IN THE RATED WALLS AND CEILINGS SHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT GASSES. THE SEALANT SHALL HAVE A T-RATING OF ONE HOUR. 5. ALL PIPING, CONDUIT, AND OUTLET BOXES (ELECTRIC, TELEPHONE, ALL PIPING, CONDUIT, AND OUTLET BOXES (ELECTRIC, TELEPHONE, COMPUTER, ETC.) IN THE RATED WALLS OR CEILING AND STC WALLS SHALL BE CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL. 6. OUTLET BOXES (ELECTRIC, TELEPHONE, COMPUTER, ETC.) SHALL BE OUTLET BOXES (ELECTRIC, TELEPHONE, COMPUTER, ETC.) SHALL BE LIMITED TO TWO OUTLET BOXES PER STUD SPACE. OUTLET BOXES ON OPPOSITE SIDES OF THE RATED WALLS SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF 24 INCHES.

AutoCAD SHX Text %%uL1%%u

AutoCAD SHX Text %%uT-1%%u

AutoCAD SHX Text %%uH1%%u

AutoCAD SHX Text

N.E.C. REQUIRED WORKING

AutoCAD SHX Text

CLEARANCE. TYPICAL.

AutoCAD SHX Text %%uDP-2%%u

AutoCAD SHX Text %%uDP-1%%u

AutoCAD SHX Text %%uHS%%u

AutoCAD SHX Text %%uHMC%%u

AutoCAD SHX Text %%uTS-L1B%%u

AutoCAD SHX Text %%uTS-L1A%%u

AutoCAD SHX Text %%uL1A%%u

AutoCAD SHX Text %%uL1B%%u

AutoCAD SHX Text

1. NOT USED. NOT USED. 2. THERE SHALL BE (3) DUPLEX RECEPTACLES FOR TELEVISIONS: ONE THERE SHALL BE (3) DUPLEX RECEPTACLES FOR TELEVISIONS: ONE MOUNTED HIGH, MIDDLE AND LOW. VERIFY MOUNTING HEIGHTS WITH ARCHITECTURAL INTERIOR ELEVATIONS. 3. CONNECT TO EXISTING RECEPTACLE CIRCUIT IN THE ROOM. CONNECT TO EXISTING RECEPTACLE CIRCUIT IN THE ROOM. 4. ALL FLEXIBLE METALLIC RACEWAY FOR 'RB' SPECIAL OUTLETS SHALL BE ALL FLEXIBLE METALLIC RACEWAY FOR 'RB' SPECIAL OUTLETS SHALL BE ROUTED BELOW THE RAISED FLOOR. FLEXIBLE METALLIC RACEWAYS FOR EACH SPECIAL OUTLET SHALL BE ROUTED BELOW THE CABLE TRAY AND TO THE ASSOCIATED PANEL VIA THE PANEL SKIRT. REFER TO SHEET TG101 FOR CABLE TRAY LOCATIONS. 5. NOT USED. NOT USED. 6. WORK IN THIS ROOM IS PRIORITY ONE TO ALLOW EXISTING WORK IN THIS ROOM IS PRIORITY ONE TO ALLOW EXISTING COMMUNICATIONS ROOM TO BE DEACTIVATED. 7. MOUNT AT 18" ABOVE PODIUM HEIGHT. MOUNT AT 18" ABOVE PODIUM HEIGHT. 8. EXTEND EXISTING CIRCUITS TO REMAIN TO NEW PANEL. EXTEND EXISTING CIRCUITS TO REMAIN TO NEW PANEL. 9. FUSTAT ABOVE ACCESSIBLE CEILING FOR CONNECTION TO POWERED FUSTAT ABOVE ACCESSIBLE CEILING FOR CONNECTION TO POWERED PROJECTION SCREEN. 10. JUNCTION BOX AT 46"AFF WITH 1"C TO ABOVE ACCESSIBLE CEILING JUNCTION BOX AT 46"AFF WITH 1"C TO ABOVE ACCESSIBLE CEILING FOR PROJECTION SCREEN CONTROLS. 11. BUSSMAN POWER MODULE SWITCH FOR ELEVATOR. REFER TO DETAIL BUSSMAN POWER MODULE SWITCH FOR ELEVATOR. REFER TO DETAIL 1/E-504. 12. 20A. 120V. BREAKER FOR ELEVATOR CAR LIGHTING. REFER TO DETAIL 20A. 120V. BREAKER FOR ELEVATOR CAR LIGHTING. REFER TO DETAIL 1/E-504. 13. MOUNT 48" ABOVE BOTTOM OF PIT. REFER TO DETAIL 1/E-504. MOUNT 48" ABOVE BOTTOM OF PIT. REFER TO DETAIL 1/E-504. 14. FUSTAT FOR MOTORIZED DAMPER. CONNECT TO SAME CIRCUIT AND FUSTAT FOR MOTORIZED DAMPER. CONNECT TO SAME CIRCUIT AND INTERLOCK WITH OPERATION OF EXISTING EXHAUST FAN IN ROOM. 15. 24-VOLT FUSTAT FOR MOTORIZED DAMPER. 24-VOLT FUSTAT FOR MOTORIZED DAMPER. 16. PUSHBUTTON FOR EMERGENCY SHUTDOWN OF HVAC EQUIPMENT. PUSHBUTTON PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR. REFERENCE MECHANICAL DETAIL. PROVIDE 24V. POWER TO PUSHBUTTON.

AutoCAD SHX Text

ALL WORK INDICATED ON THIS SHEET SHALL BE PART OF CLIN 002.

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text 80"

AutoCAD SHX Text 80"

AutoCAD SHX Text J

AutoCAD SHX Text 80"

AutoCAD SHX Text 80"

AutoCAD SHX Text J

AutoCAD SHX Text 120"

AutoCAD SHX Text J

AutoCAD SHX Text 36"

AutoCAD SHX Text 120"

AutoCAD SHX Text 120"

AutoCAD SHX Text J

AutoCAD SHX Text 120"

AutoCAD SHX Text J

AutoCAD SHX Text 72"

AutoCAD SHX Text 72"

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text 72"

AutoCAD SHX Text 72"

AutoCAD SHX Text J

AutoCAD SHX Text 72"

AutoCAD SHX Text 72"

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

PC

AutoCAD SHX Text

PC

AutoCAD SHX Text

PC

AutoCAD SHX Text

PC

AutoCAD SHX Text PERIMETER OF SECURE AREA. PENETRATIONS SHALL BE KEPT TO A MINIMUM. METALLIC CONDUITS AND PIPING THAT PENETRATE THE SECURE AREA WALLS, FLOOR, OR CEILING SHALL HAVE FLEX RUBBER SEALANT INSTALLED COMPLETELY AROUND THE PIPE/CONDUIT TO CREATE THE DIELECTRIC UNION. ALL PENETRATIONS SHALL BE DOCUMENTED ON AS-BUILT DRAWINGS. TYPICAL.

AutoCAD SHX Text

PRINTER

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

AutoCAD SHX Text

RTV

AutoCAD SHX Text

RTV

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

RB

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text %%uRU%%u

AutoCAD SHX Text %%uL2%%u

AutoCAD SHX Text

OPERATIONS

AutoCAD SHX Text

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

AutoCAD SHX Text

AREA

AutoCAD SHX Text

LOCKER

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

HALLWAY

AutoCAD SHX Text

COSA

AutoCAD SHX Text 102A

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

SQ ADMIN

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

1ST SGT.

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

CONFERENCE

AutoCAD SHX Text

AutoCAD SHX Text

OPERATIONS

AutoCAD SHX Text

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

COMM.

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

CONF

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

SSO

AutoCAD SHX Text

AutoCAD SHX Text

STAN/EVAL

AutoCAD SHX Text

AutoCAD SHX Text W & T

AutoCAD SHX Text

TRAINING/

AutoCAD SHX Text

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

AutoCAD SHX Text

MEN

AutoCAD SHX Text

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text

AutoCAD SHX Text J.C.

AutoCAD SHX Text 102B

AutoCAD SHX Text

BREAKROOM

AutoCAD SHX Text

WORKSPACE/

AutoCAD SHX Text

AutoCAD SHX Text

ACCESS

AutoCAD SHX Text

HALL

AutoCAD SHX Text

AutoCAD SHX Text

COMMANDER

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text

RB

AutoCAD SHX Text %%uBCU-7%%u

AutoCAD SHX Text %%uBCU-6%%u

AutoCAD SHX Text %%uBCU-5%%u

AutoCAD SHX Text %%uBCU-8%%u

AutoCAD SHX Text %%uERV-1%%u

AutoCAD SHX Text %%uBCU-4%%u

AutoCAD SHX Text %%uBCU-2%%u

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 80"

AutoCAD SHX Text 80"

AutoCAD SHX Text

PROJECTOR

AutoCAD SHX Text #10

AutoCAD SHX Text #10

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MSB:3

AutoCAD SHX Text

RU:8

AutoCAD SHX Text

RU:12

AutoCAD SHX Text

RU:21

AutoCAD SHX Text

RU:1

AutoCAD SHX Text

RU:39

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text %%uSP-1%%u

AutoCAD SHX Text

LU:1,3

AutoCAD SHX Text

LU:9,11

AutoCAD SHX Text

LU:17,19

AutoCAD SHX Text

LU:25,27

AutoCAD SHX Text

LU:33,35

AutoCAD SHX Text

LU:41,43

AutoCAD SHX Text

LU:5,7

AutoCAD SHX Text

LU:13,15

AutoCAD SHX Text

LU:21,23

AutoCAD SHX Text

LU:29,31

AutoCAD SHX Text

LU:37,39

AutoCAD SHX Text

LU:45,47

AutoCAD SHX Text

LU:49,51

AutoCAD SHX Text

LU:125,127

AutoCAD SHX Text

LU:65,67

AutoCAD SHX Text

LU:73,75

AutoCAD SHX Text

LU:81,83

AutoCAD SHX Text

LU:85,87

AutoCAD SHX Text

LU:77,79

AutoCAD SHX Text

LU:69,71

AutoCAD SHX Text

LU:61,63

AutoCAD SHX Text

LU:117,119

AutoCAD SHX Text

LU:2,4

AutoCAD SHX Text

LU:6,8

AutoCAD SHX Text

LU:14,16

AutoCAD SHX Text

LU:22,24

AutoCAD SHX Text

LU:30,32

AutoCAD SHX Text

LU:38,40

AutoCAD SHX Text

LU:82,84

AutoCAD SHX Text

LU:74,76

AutoCAD SHX Text

LU:66,68

AutoCAD SHX Text

LU:58,60

AutoCAD SHX Text

LU:50,52

AutoCAD SHX Text

LU:42,44

AutoCAD SHX Text

LU:46,48

AutoCAD SHX Text

LU:54,56

AutoCAD SHX Text

LU:62,64

AutoCAD SHX Text

LU:70,72

AutoCAD SHX Text

LU:78,80

AutoCAD SHX Text

LU:86,88

AutoCAD SHX Text

LU:10,12

AutoCAD SHX Text

LU:18,20

AutoCAD SHX Text

LU:26,28

AutoCAD SHX Text

LU:34,36

AutoCAD SHX Text

LU:95

AutoCAD SHX Text

LU:93

AutoCAD SHX Text

LU:89

AutoCAD SHX Text

LU:91

AutoCAD SHX Text %%uBCU-3%%u

AutoCAD SHX Text %%uUH-1%%u

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

LU:103

AutoCAD SHX Text

AutoCAD SHX Text

LU:90

AutoCAD SHX Text

LU:92

AutoCAD SHX Text

LU:94

AutoCAD SHX Text

LU:96

AutoCAD SHX Text

LU:98

AutoCAD SHX Text

LU:100

AutoCAD SHX Text

LU:102

AutoCAD SHX Text

LU:104

AutoCAD SHX Text

LU:106

AutoCAD SHX Text

LU:108

AutoCAD SHX Text

LU:110

AutoCAD SHX Text

LU:112

AutoCAD SHX Text

LU:114

AutoCAD SHX Text

LU:116

AutoCAD SHX Text

LU:118

AutoCAD SHX Text

LU:120

AutoCAD SHX Text

LU:122

AutoCAD SHX Text

LU:124

AutoCAD SHX Text

LU:126

AutoCAD SHX Text %%uLU%%u

AutoCAD SHX Text

LU:109

AutoCAD SHX Text

MTP1:2

AutoCAD SHX Text

MTP1:4

AutoCAD SHX Text

MTP1:6

AutoCAD SHX Text

RU:6

AutoCAD SHX Text

RU:4

AutoCAD SHX Text

RU:2

AutoCAD SHX Text

RU:19

AutoCAD SHX Text

RU:23

AutoCAD SHX Text

RU:17

AutoCAD SHX Text

RU:7

AutoCAD SHX Text

RU:11

AutoCAD SHX Text

RU:9

AutoCAD SHX Text

RU:1

AutoCAD SHX Text

RU:3

AutoCAD SHX Text L2:22

AutoCAD SHX Text

RU:26

AutoCAD SHX Text

RU:28

AutoCAD SHX Text L2:24

AutoCAD SHX Text

RU:26

AutoCAD SHX Text L2:3

AutoCAD SHX Text

RU:25

AutoCAD SHX Text

RU:41

AutoCAD SHX Text

RU:30

AutoCAD SHX Text L2:5

AutoCAD SHX Text

RU:27

AutoCAD SHX Text

RU:29

AutoCAD SHX Text

LU:111

AutoCAD SHX Text

LU:97

AutoCAD SHX Text L2:2

AutoCAD SHX Text S

AutoCAD SHX Text L2:4

AutoCAD SHX Text L2:6

AutoCAD SHX Text L2:10

AutoCAD SHX Text L2:16

AutoCAD SHX Text L2:14

AutoCAD SHX Text L2:8

AutoCAD SHX Text L2:12

AutoCAD SHX Text L2:23

AutoCAD SHX Text

RU:14

AutoCAD SHX Text L2:1

AutoCAD SHX Text L2:7

AutoCAD SHX Text

LU:113

AutoCAD SHX Text U:\Wichita-Facil\2011\11155\008\Elec\Drawings\As-Builts\11155-008-EP101

AutoCAD SHX Text Saved 10-30-2018 1:55:20 PM by DANNY.MINKS10-30-2018 1:55:20 PM by DANNY.MINKS by DANNY.MINKSDANNY.MINKS

AutoCAD SHX Text

APR. 28, 2017

AutoCAD SHX Text

OF 66

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text 184th CES

AutoCAD SHX Text Kansas Air National Guard

AutoCAD SHX Text McConnell AFB Wichita KS

AutoCAD SHX Text THESE DOCUMENTS INCLUDE RECORD INFORMATION PROVIDED BY THE CONTRACTOR. THIS INFORMATION HAS NOT BEEN VERIFIED IN ITS ENTIRETY BY THE DESIGN PROFESSIONAL. DATE: OCTOBER 2018

AutoCAD SHX Text

JLM

AutoCAD SHX Text

JLM

AutoCAD SHX Text

SMS

Sheet No.

Sheet:

Date:

Sheet Name:

Drawn by:

Chief Designer:

12094.020

Revisions:

Project No.

PROJECT NAME:

PRQE 072247

McConnell AFB

KANG

REPAIR

BUILDING 44

FOR CACS

F I G H T I NG JAY H AW KS

D o u g l a s

W i c h i t a

K

S

T e l

F a x w w w g l m v c o m

A rc hi te ct ur e

R E

C O

A

W I N

G S

ELECTRICAL INTERIOR

FIRST FLOOR SYSTEMS

PLAN

ET101

AutoCAD SHX Text

ELECTRICAL INTERIOR FIRST FLOOR SYSTEMS PLAN

AutoCAD SHX Text N

AutoCAD SHX Text 12'

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 0'

AutoCAD SHX Text 20'

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text A

AutoCAD SHX Text

%%UKEYED NOTES:

AutoCAD SHX Text

1. RELOCATED EXISTING DEVICE(S). RE-CONNECT TO EXISTING CIRCUITING RELOCATED EXISTING DEVICE(S). RE-CONNECT TO EXISTING CIRCUITING AS REQUIRED. 2. RELOCATED EXISTING SURFACE MOUNTED MASS NOTIFICATION FIRE ALARM PANEL. RELOCATED EXISTING SURFACE MOUNTED MASS NOTIFICATION FIRE ALARM PANEL. 3. (2) 4"C. ROUTED IN WALL FROM SECOND FLOOR DOWN TO ABOVE ACCESSIBLE (2) 4"C. ROUTED IN WALL FROM SECOND FLOOR DOWN TO ABOVE ACCESSIBLE CEILING ON FIRST FLOOR FOR TELECOMMUNICATIONS CABLING PATHWAY BETWEEN FLOORS. (2) 4"C. ROUTED IN WALL FROM BELOW FIRST FLOOR RAISED FLOOR TO ABOVE ACCESSIBLE CEILING FOR TELECOMMUNICATIONS CABLING PATHWAY. 4. INSTALL 3/4" x 8'-0"H. PLYWOOD BACKBOARD PAINTED TWO COATS WHITE WITH INSTALL 3/4" x 8'-0"H. PLYWOOD BACKBOARD PAINTED TWO COATS WHITE WITH FIRE RETARDANT PAINT. INSTALL 1/4" x 2" x 12"L. TELECOMMUNICATIONS GROUNDING BUSBAR WITH #6 AWG CU. CONNECTED TO TELECOM RACK AND #3/0 AWG CU. CONNECTED TO THE MAIN SERVICE ENTRANCE. 5. GFCI TELECOM RACK SHALL BE PROTECTED DURING CONSTRUCTION SO IT GFCI TELECOM RACK SHALL BE PROTECTED DURING CONSTRUCTION SO IT REMAINS OPERATIONAL AT ALL TIMES. WORK IN THIS ROOM IS PRIORITY ONE TO WORK IN THIS ROOM IS PRIORITY ONE TO ALLOW EXISTING COMMUNICATIONS ROOM TO BE DEACTIVATED. 6. (1) 2"C. ROUTED FROM BELOW RAISED FLOOR TO ABOVE ACCESSIBLE CEILING (1) 2"C. ROUTED FROM BELOW RAISED FLOOR TO ABOVE ACCESSIBLE CEILING FOR GFCI CABLING. ROUTE CONDUIT THROUGH JUNCTION BOX MOUNTED AT 46" AFF. PROVIDE BLANK COVERPLATE FOR J-BOX.

AutoCAD SHX Text %%uPLAN NOTES:%%u

AutoCAD SHX Text

1. ALL PENETRATIONS IN THE RATED AND STC WALLS AND CEILINGS SHALL BE ALL PENETRATIONS IN THE RATED AND STC WALLS AND CEILINGS SHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT GASSES. THE SEALANT SHALL HAVE A T-RATING OF ONE HOUR. 2. ALL PIPING, CONDUIT, AND OUTLET BOXES (ELECTRIC, TELEPHONE, COMPUTER, ALL PIPING, CONDUIT, AND OUTLET BOXES (ELECTRIC, TELEPHONE, COMPUTER, ETC.) IN THE RATED WALLS OR CEILING AND STC WALLS SHALL BE CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL. 3. OUTLET BOXES (ELECTRIC, TELEPHONE, COMPUTER, ETC.) SHALL BE LIMITED TO OUTLET BOXES (ELECTRIC, TELEPHONE, COMPUTER, ETC.) SHALL BE LIMITED TO TWO OUTLET BOXES PER STUD SPACE. OUTLET BOXES ON OPPOSITE SIDES OF THE RATED WALLS SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF 24 INCHES. 4. WHERE THE SAME DEVICE IS SHOWN IN THE SAME LOCATION ON BOTH THE WHERE THE SAME DEVICE IS SHOWN IN THE SAME LOCATION ON BOTH THE POWER AND SYSTEMS PLAN, ONLY ONE DEVICE IS REQUIRED. PROVIDE BOTH POWER AND SYSTEMS WIRING AS SHOWN. 5. THE FIRE ALARM SYSTEM SHOWN HAS BEEN DESIGNED PER THE THE FIRE ALARM SYSTEM SHOWN HAS BEEN DESIGNED PER THE REQUIREMENTS OF NFPA 72. DEVICES SHOWN INDICATE DESIGN INTENT AND SHALL BE THE MINIMUM PROVIDED. SYSTEM SUPPLIER SHALL PROVIDE ANY ADDITIONAL CODE REQUIRED DEVICES OR DEVICES REQUIRED BY THE AUTHORITY HAVING JURISDICTION.

AutoCAD SHX Text %%uDP-2%%u

AutoCAD SHX Text %%uDP-1%%u

AutoCAD SHX Text %%uHS%%u

AutoCAD SHX Text %%uHMC%%u

AutoCAD SHX Text %%uTS-L1B%%u

AutoCAD SHX Text %%uTS-L1A%%u

AutoCAD SHX Text %%uL1A%%u

AutoCAD SHX Text %%uL1B%%u

AutoCAD SHX Text

'FACP'

AutoCAD SHX Text

ALL WORK INDICATED ON THIS SHEET SHALL BE PART OF CLIN 002.

AutoCAD SHX Text

AutoCAD SHX Text 4"C.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text

RF

AutoCAD SHX Text

RF

AutoCAD SHX Text

RF

AutoCAD SHX Text

RF

AutoCAD SHX Text

RF

AutoCAD SHX Text

RF

AutoCAD SHX Text

RF

AutoCAD SHX Text

RF

AutoCAD SHX Text

RF

AutoCAD SHX Text

RF

AutoCAD SHX Text

RF

AutoCAD SHX Text PERIMETER OF SECURE AREA. PENETRATIONS SHALL BE KEPT TO A MINIMUM. ALL METALLIC CONDUITS AND PIPING THAT PENETRATE THE SECURE AREA WALLS, FLOOR, OR CEILING SHALL HAVE FLEX RUBBER SEALANT INSTALLED COMPLETELY AROUND THE PIPE/CONDUIT TO CREATE THE DIELECTRIC UNION. ALL PENETRATIONS SHALL BE DOCUMENTED ON AS-BUILT DRAWINGS.

AutoCAD SHX Text

AutoCAD SHX Text

UP

AutoCAD SHX Text

TVR

AutoCAD SHX Text

TVR

AutoCAD SHX Text

SA

AutoCAD SHX Text

SA

AutoCAD SHX Text

SA

AutoCAD SHX Text

SA

AutoCAD SHX Text

SA

AutoCAD SHX Text

SA

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

OPERATIONS

AutoCAD SHX Text

AutoCAD SHX Text

VEST.

AutoCAD SHX Text

AutoCAD SHX Text

AREA

AutoCAD SHX Text

LOCKER

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

HALLWAY

AutoCAD SHX Text

COSA

AutoCAD SHX Text 102A

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

SQ ADMIN

AutoCAD…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .