INTERFACE BETWEEN NEW AND EXISTING WORK

PLUMBING SYMBOLS (GENERAL)

PLUMBING PIPING DESIGNATIONS

PLUMBING SYMBOLS

PLUMBING ABBREVIATIONS

EQUIPMENT/FIXTURE TAGS (XX = MARKS BELOW)

Y = WHERE DETAIL OR SECTION IS SHOWN

KEYED NOTES ON DRAWINGS & SCHEDULES

X = SECTION [LETTER] OR DETAIL [NUMBER]

REVISIONS

ROOM NUMBERS

XX-1

SYMBOL DESCRIPTION

SANITARY OR WASTE LINE (ABOVE GRADE)

SANITARY OR WASTE LINE (BELOW GRADE)

HOT WATER (HW)

COLD WATER (CW)

HOT WATER RETURN (REC)

SANITARY VENT LINE

LINETYPE DESCRIPTION

NATURAL GAS PIPINGNG

WATER HAMMER ARRESTOR (WHA)

TEE - DOWN, BRANCH OUT OF BOTTOM

TEE - UP, BRANCH OUT OF TOP

DESCRIPTION

ELBOW - UP

BALL VALVE

CAP ON END OF PIPE

SLEEVE THRU WALL

RISE OR DROP IN PIPING

ELBOW - DOWN

SYMBOL

VENT THRU ROOFVTR

V VENT

FLOOR CLEANOUT

ABOVE FINISHED FLOOR

SANITARYSAN

FCO

SYMBOL

AFF

DESCRIPTION

HOT WATER RETURN

HOT WATER

HWR

HW

CW

WASHFOUNTAIN

NATURAL GAS

FLOOR DRAIN

LAVATORYLAV

FD

WF

NG

COLD WATER

FLOOR DRAIN (WITH EQUIPMENT/FIXTURE TAG & TRAP)

PIPE REDUCER (CONCENTRIC)

DIRECTION OF FLOW

UNION JOINT

GAS PRESSURE REGULATOR

GAS VALVE

COMBINATION BALANCE & SHUTOFF VALVE WITH PRESSURE TAPS

TYPICALTYP

ELECTRIC WATER COOLEREWC

WATER HAMMER ARRESTORWHA

URINALUR

PRESSURE GAUGE WITH BALL VALVE

PUMP (TRIANGLE POINTS IN DIR. OF FLOW)

AQUASTAT

CHECK VALVE

THERMOMETER

WATER CLOSETWC

HOT WATER RECIRCULATIONHWC

WALL HYDRANTWHD

HOSE BIBBHB

CIRCUIT SETTER

"Y" STRAINER

PRESSURE - TEMPERATURE RELIEF VALVE

STORAGE TANKST

DOMESTIC WATER HEATERDHW

FD-X

P

OIL WATER SEPARATOROWS

SHUTOFF VALVE

LA

Y O U T

D R A W N

R E V

IE

W E D

D sheetsof

R E

V

IS

IO

N

D A

T E

H a n so n

N o

F ile n a m e

S c a le

D a te d

W in g

Il lin o is

A ir

N a ti o n a l G u a rd

S p ri n g fi e ld

Il lin o is

-2

H a n s o n

P ro fe s s io n a l S e rv ic e s I n c

S o u th S ix th

S tr e e t

P h o n e

(2

-2

O k la m h o m a C it y

O K

-7

N G

B I

D

IQ

C o n tr a c t

W

L

-1

-D

B ro a d w a y E x te n s io n

S u it e

P h o n e

(4

-2

C o p yr ig h t H a n so n

P ro fe ss io n a l S e rv ic e s In c

R E

P A

IR

N

D I

B U

IL

D

IN

G

P -1

S P

R

IN

G F

IE

L

D

IL

ISSUED FOR CONSTRUCTION 3 MAY 2021

S ig n e d

/1

/2

E x p ir e s

/3

/2

C U s e rs

\b ra n s \D o c u m e n ts

\1 D

H

V P v s b r a n s o n .r v t

/2

/2

: 5 :3

P

M

/0

/2

P L

U M

B

IN

G N

O T

E S

L

E G

E N

D S

A

N D

A B

B R

E V

IA

T

IO

N

S

P-001

L W

B W

P

J R

F

PLUMBING GENERAL NOTES:

1. BEFORE SUBMITTING BID, CONTRACTOR SHALL VISIT THOSE PORTIONS OF THE BUILDING

AND SITE AFFECTED BY THIS WORK SO AS TO BECOME FAMILIAR WITH EXISTING

CONDITIONS AND DIFFICULTIES THAT MAY AFFECT EXECUTION OF THE WORK.

SUBMISSION OF A BID DENOTES THAT SUCH EXAMINATION HAS BEEN MADE AND CLAIMS

FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES

ENCOUNTERED MAY NOT BE RECOGNIZED. SUBMIT ANY QUESTIONS REQUIRED TO

CLARIFY SCOPE PRIOR TO BID. INCLUDE ALL REQUIRED WORK IN BID PRICE.

2. UNFORESEEN SITE CONDITIONS MAY EXIST AND EXISTING UTILITIES MAY NOT BE FIELD

LOCATED EXACTLY AS SHOWN ON THE DRAWINGS. COOPERATION WITH OTHER TRADES

IN ROUTING AND/OR BURIAL DEPTHS AS DETERMINED DURING CONSTRUCTION AND AS

DIRECTED BY THE ARCHITECT/ENGINEER MAY BE NECESSARY. IT IS INTENDED THAT

SUCH DEVIATIONS SHALL BE CONSIDERED AS PART OF THIS CONTRACT. SUCH

DEVIATIONS MAY NOT BE CONSIDERED AS PART OF THIS CONTRACT WHEN PROPERLY

DOCUMENTED IN WRITING.

3. CONCEAL ALL PIPING ABOVE CEILING OR IN NEW WALLS, UNLESS WITHIN A MECHANICAL

ROOM OR SPECIFICALLY NOTED AS EXPOSED OR SURFACE MOUNTED. CONTRACTOR TO

COORDINATE WITH THE GENERAL CONTRACTOR TO PAINT ALL EXPOSED PIPING TO

MATCH CORRESPONDING EXPOSED AREAS.

4. WORK SHALL BE PERFORMED IN COMPLIANCE WITH THE ESTABLISHED WORK SCHEDULE

SET FORTH BY OWNER. COORDINATE ALL WORK WITH GENERAL CONTRACTOR.

5. UNLESS OTHERWISE NOTED, ALL CONCRETE PATCHING, WALL PATCHING, CEILING

REPAIR, FENCE WORK AND OTHER GENERAL CONSTRUCTION WORK REQUIRED FOR

INSTALLING MECHANICAL/PLUMBING OR FIRE PROTECTION SYSTEMS SHALL BE PROVIDED

BY THE RESPECTIVE VENTILATION, HEATING, PLUMBING, OR FIRE PROTECTION

CONTRACTOR RESPONSIBLE FOR SAID WORK. THAT CONTRACTOR SHALL FULLY

COORDINATE THAT WORK WITH GENERAL CONTRACTOR USING THE APPROPRIATE

CONSTRUCTION TRADES.

6. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND SHALL BE UL LISTED WHERE

APPLICABLE.

7. PENETRATION OF THE ROOF DECK WILL NOT BE ACCEPTABLE FOR SUPPORT OF PIPING,

EQUIPMENT, OR ANY OTHER DEVICES. ALL SUPPORTS SHALL SPAN BETWEEN THE

STRUCTURAL ELEMENTS TO SUPPORT THE PLUMBING EQUIPMENT.

8. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND SHOULD NOT BE SCALED. COORDINATE

EXACT LOCATION OF ALL CEILING MOUNTED EQUIPMENT SO ALL SERVICEABLE

COMPONENTS CAN BE EASILY ACCESSED BY REMOVING CEILING TILES ONLY. REMOVAL

OR RELOCATION OF LIGHTING FIXTURES FOR SERVICE ACCESS IS NOT ACCEPTABLE. THE

CONTRACTOR SHALL REINSTALL EQUIPMENT THAT HAS INADEQUATE OR UNSAFE

ACCESSIBILITY. LOCATE ALL OTHER EQUIPMENT WITH MANUFACTURER RECOMMENDED

ACCESS FOR OPERATION AND MAINTENANCE. INSTALL EQUIPMENT WITH PROPER

ELECTRICAL CODE CLEARANCES.

9. COMPLY WITH DIVISION 26 OF THE CONTRACT SPECIFICATIONS REFERRING TO MOTORS,

STARTERS, VFD’S, ETC.

10. WHENEVER A REFERENCE IS MADE TO A STANDARD, THE WORK SHALL COMPLY WITH

THE LATEST PUBLISHED EDITION OF THE STANDARD AT THE TIME THE PROJECT IS BID

UNLESS OTHERWISE SPECIFIED.

11. ALL MATERIAL STORED ON SITE SHALL BE PROPERLY PROTECTED FROM INJURY OR

DETERIORATION. MATERIAL SHALL NOT BE STORED IN CONTACT WITH THE GROUND.

12. REFER TO DIVISION 22 SPECIFICATIONS FOR ADDITIONAL INFORMATION AND ALL

REQUIREMENTS NOT INDICATED ON THE DRAWINGS. IF THERE ARE ANY APPARENT

CONFLICTS BETWEEN THE SPECIFICATIONS AND DRAWINGS, THE MORE STRINGENT

REQUIREMENTS SHALL APPLY. NOTIFY THE ARCHITECT/ENGINEER OF ANY CONFLICTS

PRIOR TO PURCHASING EQUIPMENT AND PRIOR TO CUTTING OPENINGS.

13. ALL EQUIPMENT, PIPING, AND VALVES SHALL HAVE IDENTIFICATION LABELS AND TAGS

PER SPECIFICATION SECTION 22 05 53.

14. VERIFY EXISTING CONDITIONS IN THE FIELD AND COORDINATE WITH ALL TRADES PRIOR

TO INSTALLING OR FABRICATING EQUIPMENT.

15. ALL WORK, AT A MINIMUM, SHALL BE IN ACCORDANCE WITH OSHA, NFPA STANDARDS, THE

PLUMBING CODE, AND THE LOCAL GOVERNING AUTHORITIES. THE DRAWINGS AND

SPECIFICATIONS DO NOT ATTEMPT TO INDICATE ALL WORK REQUIRED BY THE CODES AND

AUTHORITIES. DO NOT INSTALL WORK THAT DOES NOT MEET THE MINIMUM

REQUIREMENTS. IF NECESSARY, REQUEST CLARIFICATION FROM A/E PRIOR TO

PROCEEDING.

16. CONTRACTOR SHALL NOT CONCEAL ANY WORK UNTIL INSPECTED BY PLUMBINGS

INSPECTOR AND/OR THE WORK IS OBSERVED BY THE ARCHITECT/ENGINEER.

CONTRACTOR SHALL NOTIFY THE A/E OF A SCHEDULED INSPECTION/REVIEW TIME WITHIN

72 HOURS. GENERAL CONTRACTOR SHALL NOT CONCEAL WORK UNTIL INSPECTED AND

OBSERVED, REGARDLESS OF SCHEDULE.

17. PRIME CONTRACTOR IS RESPONSIBLE TO HAVE LICENSED AND QUALIFIED

SUBCONTRACTORS PERFORMING ALL WORK.

18. CONTRACTOR SHALL MAINTAIN A MARKED-UP SET OF RECORD DRAWINGS WHICH

INDICATE VARIATIONS IN THE ACTUAL INSTALLATION FROM THE ORIGINAL DESIGN.

SUBMIT DRAWINGS TO OWNER AND A/E UPON COMPLETION FOR REVIEW.

19. THE SIZE, LOCATION, WEIGHT, ELECTRICAL REQUIREMENTS AND SERVICE CLEARANCES

OF EQUIPMENT INSTALLED UNDER DIVISION 22 SHALL BE COORDINATED WITH ALL OTHER

TRADES.

20. ROUGH IN SIZES FOR BRANCH PIPING SHALL BE AS INDICATED ON THE PLUMIBNG

MATERIAL LIST. PROVIDE A MINIMUM OF 1/2” FOR DOMESTIC WATER PIPING RUNOUTS TO

ALL EQUIPMENT UNLESS SPECIFICALLY NOTED OTHERWISE.

21. CONTRACTOR SHALL PROVIDE COORDINATED SHOP DRAWINGS PRIOR TO PROCURING

OR INSTALLING EQUIPMENT AND SYSTEMS INDICATED ON CONTRACT DOCUMENTS.

SUBMIT IN STRICT ACCORDANCE WITH THE SPECIFICATIONS. PRIOR TO SUBMITTAL,

CONTRACTOR SHALL VERIFY THAT ADEQUATE SPACE EXISTS FOR THE SUBMITTED

EQUIPMENT. SHOP DRAWINGS SHALL BE REVIEWED BY ENGINEER AND ARCHITECT.

22. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS INCURRED BY OTHER

TRADES DUE TO SUBSTITUTION OF OTHER THAN SCHEDULED EQUIPMENT. WHEN

EQUIPMENT FURNISHED IS DIFFERENT THAN INDICATED, THE COST OF ADDITIONAL

ELECTRICAL SERVICE, STRUCTURAL AND RELATED WORK SHALL BE PAID BY THIS

CONTRACTOR.

23. PIPE INSTALLATION HEIGHTS WHEREVER PROVIDED ON THE DRAWINGS ARE INTENDED

FOR GUIDANCE PURPOSES ONLY. RESPECTIVE CONTRACTORS SHALL BE RESPONSIBLE

FOR SHOP DRAWINGS, PROPER INSTALLATION OF SYSTEM AND COORDINATION AMONG

TRADES.

24. ALL PIPING AND DUCT PENETRATIONS THROUGH FLOOR AND WALLS SHALL BE MADE

THROUGH NEATLY CUT OR DRILLED OPENINGS. PROVIDE SLEEVES THROUGH RATED

WALLS. SEAL AROUND ALL PENETRATIONS. SEAL NON-RATED WALLS WITH GROUT OR

CAULK. BACKING MATERIAL MAY BE USED. SEAL PENETRATIONS IN ALL RATED WALLS

WITH 3M FIRE BARRIER SYSTEM, DOW CORNING FIRE STOP OR APPROVED EQUAL.

25. INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER’S

RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE OR WHERE LOCAL

CODES OR REGULATIONS TAKE PRECEDENCE.

26. REPAIR ALL ACCIDENTAL OR INTENTIONAL DAMAGE TO MATCH NEW AND

EXISTING CONSTRUCTION WITH NO NOTICEABLE DIFFERENCE IN CONTINUITY,

APPEARANCE, OR FUNCTION.

27. RESPECTIVE CONTRACTORS SHALL BE RESPONSIBLE FOR REINFORCED

CONCRETE PADS FOR ALL EQUIPMENT BEING PROVIDED UNDER THEIR

CONTRACT. EACH PAD SHALL HAVE 1”/45° CHAMFERED EDGE ALONG PERIMETER.

28. REMOVE AND REINSTALL ACOUSTICAL TILE CEILING AS REQUIRED TO PERFORM

WORK SHOWN ON DRAWINGS.

29. ALL NEW ROOF PENETRATIONS, AND PATCHES FOR REMOVED PENETRATIONS,

SHALL BE INSTALLED AND SEALED PER THE ROOFING MANUFACTURER’S

GUIDELINES TO MAINTAIN ROOF WARRANTY. CONSULT ROOFING MANUFACTURER

PRIOR TO CREATING NEW PENETRATIONS.

30. IT IS THE INTENT OF THESE PLANS AND SPECIFICATION TO PROVIDE A WORKING

INSTALLATION IN EVERY DETAIL AND ALL ITEMS REQUIRED FOR SUCH AND

INSTALLATION SHALL BE PROVIDED WHETHER OR NOT SPECIFICALLY INDICATED

OR MENTIONED.

31. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION AND

PROPER INSTALLATION OF ALL PLUMBING SYSTEMS INCLUDED WITHIN THE

SCOPE OF THIS PROJECT.

32. PIPING INSTALLATION HEIGHTS WHENEVER PROVIDED ON THE PROJECT

CONSTRUCTION DRAWINGS ARE INTENDED FOR GUIDANCE PURPOSES ONLY.

PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF THE

INSTALLATION HEIGHTS AND THE ASSOCIATED COORDINATION BETWEEN

CONSTRUCTION TRADES PRIOR TO INSTALLATION OF THE PLUMBING SYSTEMS.

33. LOCATION AND SIZE OF EXISTING PLUMBING PIPING SYSTEMS SHOWN IN THE

PROJECT CONSTRUCTION DRAWINGS IS BASED UPON INFORMATION GATHERED

FROM EXISTING BUILDING DRAWINGS AND FIELD OBSERVATIONS. THE ACCURACY

OF THIS INFORMATION CANNOT BE ASSURED. PLUMBING CONTRACTOR SHALL BE

RESPONSIBLE FOR FIELD VERIFICATION PRIOR TO THE PROCUREMENT OF NEW

PLUMBING SYSTEM MATERIALS.

34. PIPING PENETRATIONS THROUGH EXISTING MASONRY OR CONCRETE FLOORS,

WALLS, CEILINGS AND ROOFS SHALL BE MADE THROUGH CORED OPENINGS.

PIPING PENETRATIONS THROUGH NEW MASONRY OR CONCRETE FLOORS,

WALLS, CEILINGS AND ROOFS SHALL BE MADE THROUGH EITHER SLEEVED OR

CORED OPENINGS.

35. PIPING PENETRATIONS THROUGH FIRE AND SMOKE RATED ASSEMBLIES SHALL

BE SEALED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND DRAWING

DETAILS SHOWN IN THE PROJECT CONSTRUCTION DRAWINGS TO MAINTAIN THE

RATING OF THE FIRE AND SMOKE ASSEMBLIES. REFER TO THE PROJECT

ARCHITECTURAL CONSTRUCTION DRAWINGS FOR THE LOCATION OF FIRE AND

SMOKE RATED ASSEMBLIES.

36. PLUMBING FIXTURES INSTALLED WITHIN THE SCOPE OF THIS PROJECT SHALL BE

KEPT CLEAN UNTIL THE PROJECT HAS RECEIVED FINAL ACCEPTANCE BY THE

FACILITY OWNER.

37. ISOLATION VALVES INSTALLED IN DOMESTIC WATER BRANCH PIPING THAT

SUPPLIES EMERGENCY SHOWER AND EYE/FACE WASH FIXTURES SHALL HAVE

THEIR VALVE ACTUATORS REMOVED BY THE PLUMBING CONTRACTOR AFTER THE

ISOLATION VALVES HAVE BEEN PLACED IN THEIR FULLY OPEN POSITION. THE

PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING THE VALVE

ACTUATORS TO THE DOMESTIC WATER BRANCH PIPING DIRECTLY ADJACENT TO

THE ISOLATION VALVES FROM WHICH THE VALVE ACTUATORS WERE REMOVED.

38. TO ACCOMMODATE MODIFICATIONS TO THE EXISTING PLUMBING SYSTEMS

INCLUDED WITHIN THE SCOPE OF THIS PROJECT, THE PLUMBING CONTRACTOR

SHALL COORDINATE THE TEMPORARY SHUTDOWN OF THESE SYSTEMS WITH THE

FACILITY OWNER’S REPRESENTATIVE (NAME: XXX, PHONE NUMBER: XXX) PRIOR

TO PROCEEDING WITH CONSTRUCTION WORK.

39. SUPPORT FOR ALL PLUMBING FIXTURES SHALL BE PROVIDED BY THE PLUMBING

CONTRACTOR. COORDINATE INSTALLATION WITH OTHER TRADES INVOLVED.

40. INSTALL A READILY ACCESSIBLE SHUTOFF VALVE IN ALL BRANCH PIING WATER

LINES SERVING ANY ROOM WITH PLUMBING FIXTURES. IF REQUIRED ABOVE

DRYWALL CEILING, A FLUSH FIT ACCESS PANEL SHALL BE PROVIDED.

41. HAND LEVERS FOR SHUTOFF VALVES CONNECTED TO THE EMERGENCY SHOWER

AND EYE/FACE WASH FIXTURES SHALL BE REMOVED AND ZIP-TIED TO THE

ASSOCATED PIPING SYSTEM AFTER THE VALVES HAVE BEEN PLACED IN THE

OPEN POSITION.

42. HANDLEVERS FOR SHUTOFF VALVES CONNECTED TO THE EMERGENCY SHOWER

AND EYE/FACE WASH FIXTURE SHALL BE REMOVED AND ZIP-TIED TO THE

ASSOCIATED PIPING SYSTEM AFTER THE VALVES HAVE BEEN PLACED IN THE

OPEN POSITION.

AA

BB

CC

DD

EE

2 2

~3'-0" Ø

LA

Y O U T

D R A W N

R E V

IE

W E D

D sheetsof

R E

V

IS

IO

N

D A

T E

H a n so n

N o

F ile n a m e

S c a le

D a te d

W in g

Il lin o is

A ir

N a ti o n a l G u a rd

S p ri n g fi e ld

Il lin o is

-2

H a n s o n

P ro fe s s io n a l S e rv ic e s I n c

S o u th

S ix th S tr e e t

P h o n e

(2

-2

O k la m h o m a C it y

O K

-7

N G

B I

D

IQ

C o n tr a c t

W

L

-1

-D

B ro a d w a y E x te n s io n

S u it e

P h o n e

(4

-2

C o p yr ig h t H a n so n

P ro fe ss io n a l S e rv ic e s In c

R E

P A

IR

N

D I

B U

IL

D

IN

G

P -1

S P

R

IN

G F

IE

L

D

IL

ISSUED FOR CONSTRUCTION 3 MAY 2021

S ig n e d

/1

/2

E x p ir e s

/3

/2

C U s e rs

\b ra n s \D o c u m e n ts

\1 D

H

V P v s b r a n s o n .r v t

/2

/2

: 5 :0

P

M

/0

/2

F

IR

S T

F L

O O

R S

A N

IT

A

R Y

W A

S T

E

V E

N T

P

IP

IN

G

D E

M O

L

IT

IO

N

P L

A N

PD-101

L W

B W

P

J R

F

1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.

2. REFER TO SPECIFICATIONS.

GENERAL SHEET NOTES

SHEET KEYNOTES

ABOVE AND BELOW GRADE SANITARY WASTE AND VENT PIPING TO REMAIN.

ABOVE AND BELOW GRADE SANITARY WASTE AND VENT PIPING TO BE

REMOVED.

TRENCH DRAIN AND ASSOCIATED SANITARY WASTE AND VENT PIPING TO BE

REMOVED.

EXISTING OIL / WATER SEPARATOR (OWS) TO BE REMOVED. CONTRACTOR

SHALL BE RESPONSIBLE FOR REMOVING AND PROPERLY DISPOSING OF ANY

OIL AND SEDIMENT LOCATED IN THE OWS. OUTLET PIPING FROM THE OWS

SHALL BE REMOVED UP TO THE SANITARY MAIN TRAVELING EAST. SANITARY

MAIN TRAVELING EAST ON THE NORTH SIDE OF THE BUILDING TO REMAIN.

INLET PIPING AND ASSOCIATED VENT PIPING TO BE REMOVED.

EXISTING SETTLING TANK TO BE REMOVED. CONTRACTOR SHALL BE

RESPONSIBLE FOR REMOVING AND PROPERLY DISPOSING OF ANY OIL /

WATER AND SEDIMENT LOCATED IN THE SETTLING TANK. TANK DIMENSIONS

ARE APPROXIMATELY 3' Ø x 4'-6" DEEP.

EXISTING 6" SANITARY PIPING DOWNSTREAM OF CLEANOUT TO REMAIN.

REFER TO 1 / P-101 FOR NEW PIPING TO BE CONNECTED TO THE EXISTING

LINE.

1/8" = 1'-0"1

FIRST FLOOR SANITARY - DEMOLITION

4'0 8' 16'

TRUE

NORTH

PLAN

NORTH

PD-102

AA

BB

CC

DD

EE

1 1 1

1 1

DD

EE

LA

Y O U T

D R A W N

R E V

IE

W E D

D sheetsof

R E

V

IS

IO

N

D A

T E

H a n so n

N o

F ile n a m e

S c a le

D a te d

W in g

Il lin o is

A ir

N a ti o n a l G u a rd

S p ri n g fi e ld

Il lin o is

-2

H a n s o n

P ro fe s s io n a l S e rv ic e s I n c

S o u th

S ix th S tr e e t

P h o n e

(2

-2

O k la m h o m a C it y

O K

-7

N G

B I

D

IQ

C o n tr a c t

W

L

-1

-D

B ro a d w a y E x te n s io n

S u it e

P h o n e

(4

-2

C o p yr ig h t H a n so n

P ro fe ss io n a l S e rv ic e s In c

R E

P A

IR

N

D I

B U

IL

D

IN

G

P -1

S P

R

IN

G F

IE

L

D

IL

ISSUED FOR CONSTRUCTION 3 MAY 2021

S ig n e d

/1

/2

E x p ir e s

/3

/2

C U s e rs

\b ra n s \D o c u m e n ts

\1 D

H

V P v s b r a n s o n .r v t

/2

/2

: 5 :0

P

M

/0

/2

F

IR

S T

F L

O O

R D

O M

E S

T

IC

W A

T E

R P

IP

IN

G D

E M

O L

IT

IO

N

P L

A N

PD-102

L W

B W

P

J R

F

1/8" = 1'-0"1

FIRST FLOOR DOMESTIC WATER PIPING

DEMOLITION PLAN

1/4" = 1'-0"2

ENLARGED MEHCANICAL ROOM DOMESTIC

WATER PIPING DEMOLTION PLAN

4'0 8' 16'

0 2' 4' 8'

1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.

2. REFER TO SPECIFICATIONS.

GENERAL SHEET NOTES

SHEET KEYNOTES

REMOVE ALL EXISTING DOMESTIC COLD WATER, HOT WATER, NON-POTABLE

WATER AND ABOVE GRADE CONDENSATE PIPING AS SHOWN. REMOVE ALL

ASSOCIATED HANGERS AND SUPPORTS. REMOVE ALL EMERGENCY

EYEWASH STATIONS.

REMOVE EXISTING WATER HEATER. REMOVE ALL ASSOCIATED PIPING,

CONTROLS, HANGERS AND SUPPORTS.

TRUE

NORTH

PD-103

AA

BB

CC

DD

EE

DD

EE

LA

Y O U T

D R A W N

R E V

IE

W E D

D sheetsof

R E

V

IS

IO

N

D A

T E

H a n so n

N o

F ile n a m e

S c a le

D a te d

W in g

Il lin o is

A ir

N a ti o n a l G u a rd

S p ri n g fi e ld

Il lin o is

-2

H a n s o n

P ro fe s s io n a l S e rv ic e s I n c

S o u th

S ix th S tr e e t

P h o n e

(2

-2

O k la m h o m a C it y

O K

-7

N G

B I

D

IQ

C o n tr a c t

W

L

-1

-D

B ro a d w a y E x te n s io n

S u it e

P h o n e

(4

-2

C o p yr ig h t H a n so n

P ro fe ss io n a l S e rv ic e s In c

R E

P A

IR

N

D I

B U

IL

D

IN

G

P -1

S P

R

IN

G F

IE

L

D

IL

ISSUED FOR CONSTRUCTION 3 MAY 2021

S ig n e d

/1

/2

E x p ir e s

/3

/2

C U s e rs

\b ra n s \D o c u m e n ts

\1 D

H

V P v s b r a n s o n .r v t

/2

/2

: 5 :0

P

M

/0

/2

F

IR

S T

F L

O O

R C

O M

P R

E S

S E

D A

IR

P

IP

IN

G D

E M

O L

IT

IO

N

P L

A N

PD-103

L W

B W

P

J R

F

1/8" = 1'-0"1

FIRST FLOOR COMPRESSED AIR PIPING

DEMOLITION PLAN

1/4" = 1'-0"2

ENLARGED MECHANICAL ROOM COMPRESSED

AIR PIPING DEMOLITION PLAN

4'0 8' 16'

0 2' 4' 8'

1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.

2. REFER TO SPECIFICATIONS.

GENERAL SHEET NOTES

SHEET KEYNOTES

REMOVE ALL EXISTING COMPRESSED AIR PIPING AS SHOWN. REMOVE ALL

ASSOCIATED HOSE REELS, HANGERS AND SUPPORTS AND PIPING

ACCESSORIES. ALL HOSE REELS SHALL BE SALVAGED AND TURNED OVER

TO THE OWNER.

DISCONNECT AND TURN OVER EXISTING KAESER AIR COMPRESSOR TO

OWNER. EXISTING AIR COMPRESSOR TO BE SALVAGED AND REINSTALLED

BY CONTRACTOR, REFER TO P-104 FOR NEW COMPRESSED AIR PIPING

LAYOUT.

TRUE

NORTH

CC

EE

FCO-1

4" SAN

3" SAN

3" VENT DOWN

TO BELOW FLOOR.

4" VENT UP

THROUGH ROOF.

4" SAN

4" SAN

4"SAN

FD-1

FCO-1

2" V

3" SAN

3" V

3" V

4" SAN

3" VENT DOWN

TO BELOW FLOOR.

3" SAN

SHEET METAL

SHOP #1

MECHANICAL

SHEET METAL

SHOP

MEN

WOMEN

OFFICE

METALS TECH. #2

METALS TECH #1

A.G.E. #1

3" VTR

FD-1

ESEFW-1

TD-2

ESEFW-1

FD-1

3" SAN

FCO-1

ESEFW-1

FD-13

FCO-1

FCO-1

FCO-1

3" VTR

FD-1

1-1/2" V

4" SAN

4" V

FD-1

S-2

ESEFW-1

P-101

OWS-1

4" SAN

6" SAN

3" VTR

3" VENT DOWN

TO BELOW FLOOR.

FD-1

ESEFW-1

3" V

3" SAN

3" V

3" SAN

D

E

3 4

YCO-1

6" SAN

FCO-1

FCO-1

FD-1

S-1

FD-1FD-1

WC-1 WC-1

LAV-1

LAV-1

LAV-1

FD-1

WCO-1

UR-1

FCO-1

4" SAN

TD-1TD-1

2" SAN

3" SAN

4" SAN

2" SAN

3" SAN

4" SAN

2" SAN

4" SAN

4" SAN

3" SAN

3" SAN

3" V

REFER TO CIVIL

SHEETS FOR

CONTINUATION

1-1/2" V

4" V

4" VENT UP

THROUGH ROOF

2" V 4" V

YCO-1

4" SAN

6" SAN

WOMEN

OFFICE

CORR.

VEST.

MEN

105SHEET METAL

SHOP #1

LA

Y O U T

D R A W N

R E V

IE

W E D

D sheetsof

R E

V

IS

IO

N

D A

T E

H a n so n

N o

F ile n a m e

S c a le

D a te d

W in g

Il lin o is

A ir

N a ti o n a l G u a rd

S p ri n g fi e ld

Il lin o is

-2

H a n s o n

P ro fe s s io n a l S e rv ic e s I n c

S o u th

S ix th S tr e e t

P h o n e

(2

-2

O k la m h o m a C it y

O K

-7

N G

B I

D

IQ

C o n tr a c t

W

L

-1

-D

B ro a d w a y E x te n s io n

S u it e

P h o n e

(4

-2

C o p yr ig h t H a n so n

P ro fe ss io n a l S e rv ic e s In c

R E

P A

IR

N

D I

B U

IL

D

IN

G

P -1

S P

R

IN

G F

IE

L

D

IL

ISSUED FOR CONSTRUCTION 3 MAY 2021

S ig n e d

/1

/2

E x p ir e s

/3

/2

C U s e rs

\b ra n s \D o c u m e n ts

\1 D

H

V P v s b r a n s o n .r v t

/2

/2

: 5 :3

P

M

/0

/2

F

IR

S T

F L

O O

R S

A N

IT

A

R Y

A N

D W

A S

T E

V

E N

T P

IP

IN

G

N E

W W

O R

K P

L A

N

P-101

L W

B W

P

J R

F

1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.

2. REFER TO SPECIFICATIONS.

GENERAL SHEET NOTES

SHEET KEYNOTES

TRENCH DRAIN "TD-2" (MINIMUM 26'-4" LENGTH REQUIRED. CATCH BASIN

INCLUDED IN MINIMUM REQUIRED LENGTH).

TRENCH DRAIN "TD-2" (MINIMUM 11'-6" LENGTH REQUIRED. CATCH BASIN

INCLUDED IN MINIMUM REQUIRED LENGTH).

FLOOR DRAIN "FD-1" SHALL BE INSTALLED IN THE LOCATION SHOWN TO SERVE

THE NEW EMERGENCY SHOWER AND EYE/FACE WASH FIXTURE. TOP ELEVATION

OF FLOOR DRAIN SHALL BE INSTALLED FLUSH WITH THE ELEVATION OF THE

DEPRESSED CONCRETE FLOOR SLAB THAT WILL BE POURED IN THE AREA

DEPICTED BY THE LIGHT-COLORED BOX (REFER TO STRUCTURAL DRAWINGS

FOR ELEVATION OF DEPRESSED FLOOR SLAB). DEPRESSED FLOOR SLAB (USED

TO MINIMIZE RUNOFF OF WASTE WATER GENERATED BY THE EMERGENCY

FIXTURE) WILL BE COVERED WITH GRATING. PROCUREMENT AND INSTALLATION

OF GRATING IS EXCLUDED FROM THE PLUMBING CONTRACTOR'S SCOPE OF

WORK. REFER TO DETAIL 10 / S-501.

REFER TO THE FIRST FLOOR SANITARY WASTE AND VENT PIPING NEW WORK

ENLARGED SCALE PLAN ON THIS SHEET FOR WORK IN THIS AREA. ALSO REFER

TO THE SANITARY WASTE AND VENT PIPING ISOMETRIC SHOWN ON THIS SHEET

FOR WORK IN THIS AREA.

ROUTE 3" VENTS UP CLOSE TO WALL (TYP. OF 3), 4" VENT THROUGH ROOF.

VENTS MAY BE COMBINED OR CONNECTED TO A HEADER (6" ABOVE FLOOR

MIN.) AND EXTEND TO 4" VENT THROUGH ROOF.

TRENCH DRAIN "TD-2" (MINIMUM 13'-1" LENGTH REQUIRED. CATCH BASIN

INCLUDED IN MINIMUM REQUIRED LENGTH).

EXISTING BELOW GRADE SANITARY WASTE PIPING TO REMAIN. PIPING TO BE

CLEANED AND JETTED AND ANY PIPE BLOCKAGES REMOVED.

INSTALL NEW FLUID LEVEL SENSOR ALARM PANEL FOR THE NEW OIL/WATER

SEPARATOR IN THE A.G.E. SHOP.

TIE EXISTING 3" VENT INTO NEW SANITARY VENT PIPING.

SCALE: 1/8" = 1'-0"1

FIRST FLOOR SANITARY WASTER & VENT PIPING

NEW WORK PLAN

1/4" = 1'-0"2

ENLARGED FIRST FLOOR SANITARY WASTE &

VENT PIPING NEW WORK PLAN

4'0 8' 16'

0 2' 4' 8'

TRUE

NORTH

A

B

C

D

E

1 2 3 4 5 6 7 8

WH-1

HB-1

WH-1

HB-1

WH-1

WH-1

HB-1

HB-1

WH-1

2" DCW

1-1/2" DHW

3/4" DCW

3/4" DCW

3/4" DCW

3/4" DCW

3/4" DCW

1-1/4" DHW

1-1/2" DCW

1-1/4" DHW

1-1/2" DCW

1" DHW

1-1/4" DCW

1-1/4" DCW

1-1/4" DCW

1-1/2" DCW

1-1/4" DHW

1-1/2" DCW

2"

3/4" DHW

3/4" DCW

3/4" DCW

3/4" DHW

3/4" DCW

HB-1

3/4" DCW

3/4" DHW

HB-1

WH-1

2"

EXISTING

2" MAIN

DWH-1

HB-1

S-2

SHEET METAL

SHOP

MECHANICAL

METALS TECH. #2

METALS TECH #1

A.G.E. #1

SHEET METAL

SHOP #1

TO H-2

TO H-1

D

E

HB-1

WH-1

ET-1

DWH-1

2" DCW

2" DCW

2" DCW

2" DHW

3/4" DHW-RCRC

3/4" DHW-RCRC

2" DCW

1 1/2" DHW

2" DCW

3/4" DCW

1 1/2" DCW

1 1/4" DHW

3/4" DHW-RCRC

BFP-112

WATER METER

CP-1

D

E

3 4 5

S-1

WC-1 WC-1

LAV-1

LAV-1

LAV-1

UR-1

SH-1

SH-1

WH-1

3/4" DHW-RCRC

1-1/4" DCW

3/4" DHW

3/4" DCW

3/4" DCW

3/4" DHW

3/4" DHW-RCRC

1-1/2" DCW

3/4" DCW

3/4" DHW

1-1/2"

1-1/2" DCW

1-1/2" DHW

1-1/2" DCW

2" DCW 1-1/2" DHW

3/4" DHW-RCRC

3/4" DCW

3/4" DHW

3/4" DHW-RCRC

3/4" DCW 1/2" DCW

1/2" DHW

1" DCW

1/2" DCW

1/2" DHW 13

CIRCUIT SETTER (TYP.)

OFFICE

101VEST.

WOMEN

MEN

CHECK VALVE (TYP.)

LA

Y O U T

D R A W N

R E V

IE

W E D

D sheetsof

R E

V

IS

IO

N

D A

T E

H a n so n

N o

F ile n a m e

S c a le

D a te d

W in g

Il lin o is

A ir

N a ti o n a l G u a rd

S p ri n g fi e ld

Il lin o is

-2

H a n s o n

P ro fe s s io n a l S e rv ic e s I n c

S o u th

S ix th S tr e e t

P h o n e

(2

-2

O k la m h o m a C it y

O K

-7

N G

B I

D

IQ

C o n tr a c t

W

L

-1

-D

B ro a d w a y E x te n s io n

S u it e

P h o n e

(4

-2

C o p yr ig h t H a n so n

P ro fe ss io n a l S e rv ic e s In c

R E

P A

IR

N

D I

B U

IL

D

IN

G

P -1

S P

R

IN

G F

IE

L

D

IL

ISSUED FOR CONSTRUCTION 3 MAY 2021

S ig n e d

/1

/2

E x p ir e s

/3

/2

C U s e rs

\b ra n s \D o c u m e n ts

\1 D

H

V P v s b r a n s o n .r v t

/2

/2

: 5 :4

P

M

/0

/2

F

IR

S T

F L

O O

R D

O M

E S

T

IC

W A

T E

R P

IP

IN

G N

E W

W O

R K

P L

A N

P-102

L W

B W

P

J R

F

1/8" = 1'-0"1

FIRST FLOOR DOMESTIC WATER PIPING NEW

WORK PLAN

1/4" = 1'-0"2

ENLARGED MECHANICAL ROOM DOMESTIC

WATER PIPING NEW WORK PLAN

1/4" = 1'-0"3

ENLARGED RESTROOM DOMESTIC WATER PIPING

NEW WORK PLAN

1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.

2. REFER TO DIVISION 22 SPECIFICATIONS.

GENERAL SHEET NOTES

SHEET KEYNOTES

EMERGENCY SHOWER AND EYE/FACE WASH FIXTURE "ESEFW-1" SHALL BE

INSTALLED IN THE LOCATION SHOWN. A DEPRESSED CONCRETE FLOOR SLAB

(USED TO MINIMIZE RUNOFF OF WASTE WATER GENERATED BY THE

EMERGENCY FIXTURE) WILL BE POURED IN THE AREA DEPICTED BY THE LIGHT-

COLORED BOX. THE DEPRESSED FLOOR SLAB WILL BE COVERED WITH GRATING

THAT IS PROCURED AND INSTALLED BY OTHERS. THE EMERGENCY FIXTURE

SHOWER HEAD SHALL BE INSTALLED CENTERED OVERTOP OF THE DEPRESSED

CONCRETE FLOOR SLAB. SCH. 40 SOLID WALL PVC PIPE, SCH. 40 GALVANIZED

STEEL PIPE OR TYPE "L" COPPER SHALL BE USED TO INDIRECTLY DRAIN THE

EMERGENCY EYE/FACE WASH COMPONENT OF THE FIXTURE THROUGH THE

GRATING INSTALLED OVERTOP OF THE DEPRESSED FLOOR SLAB. THE INDIRECT

WASTE PIPE SHALL NOT INTERFERE WITH THE ADA CLEARANCE OF THE

EMERGENCY FIXTURE.

3/4" DOMESTIC WATER PIPING SHALL CONNECT TO THERMOSTATIC MIXING

VALVE "TMV-1" THAT SERVES THE NEW EMERGENCY SHOWER AND EYE/FACE

WASH FIXTURE "ESEFW-1". DOMESTIC WATER PIPING FROM THE THERMOSTATIC

MIXING VALVE SHALL CONNECT FULL LINE SIZE TO THE EMERGENCY FIXTURE.

THE SUPPLY TEMPERATURE SET POINT OF THE THERMOSTATIC MIXING VALVE

SHALL BE ADJUSTED TO 85°F.

REFER TO THE RESTROOM DOMESTIC WATER PIPING NEW WORK ENLARGED

SCALE PLAN ON THIS SHEET FOR WORK IN THIS AREA. ALSO REFER TO THE

DOMESTIC WATER PIPING ISOMETRIC SHOWN ON THIS SHEET FOR WORK IN

THIS AREA.

REFER TO THE MECHANICAL ROOM DOMESTIC WATER PIPING NEW WORK

ENLARGED SCALE PLAN ON THIS SHEET FOR WORK IN THIS AREA. ALSO REFER

TO THE DOMESTIC WATER PIPING ISOMETRIC SHOWN ON THIS SHEET FOR

WORK IN THIS AREA.

75 GALLON, 76,000 BTU/H, GAS-FIRED DOMESTIC WATER HEATER (DHW-1,

WESTINGHOUSE WGR080-076) SECURELY MOUNTED ON 4" THICK CONCRETE

HOUSEKEEPING PAD AND CONNECTED TO HOT AND COLD WATER PIPING AS

SHOWN. PROVIDE GAS VALVE AND DIRT LEG TO CONNECT DOMESTIC WATER

HEATER TO GAS PIPING. PROVIDE 3/4" DRAIN PIPING FROM

TEMPERATURE/PRESSURE RELIEF VALVE TO FLOOR DRAIN. PROVIDE AIR GAP

CONNECTION AT FLOOR DRAIN. PROVIDE CONDENSATE NEUTRALIZER AS

REQUIRED PER MANUFACTURER. REFER TO DETAIL 5 ON SHEET P-501 FOR

ADDITIONAL INFORMATION. COORDINATE CONCENTRIC FLUE VENT PIPING

INSTALLATION WITH VENTILATING CONTRACTOR. WATER HEATER SHALL BEAR

ENERGY STAR CERTIFICATION LABEL. REFER TO SPECIFICATION SECTION

223400 FOR ADDITIONAL ACCEPTABLE MANUFACTURERS.

2" WATER MAIN SHALL BE ROUTED BELOW SLAB FROM NEW CONNECTION POINT

TO MECHANICAL ROOM. PROVIDE FITTINGS, AS REQUIRED, TO CONNECT NEW

PIPE TO EXISTING BELOW GRADE.

CONNECT DOMESTIC HOT AND COLD WATER PIPING TO THERMOSTATIC MIXING

VALVE "TMV-2" SERVING THE LAVATORY. DOMESTIC WATER PIPING FROM THE

THERMOSTATIC MIXING VALVE SHALL CONNECT TO THE HOT SIDE OF THE

LAVATORY FIXTURE. THE SUPPLY TEMPERATURE SET POINT OF THE

THERMOSTATIC MIXING VALVE SHALL BE ADJUSTED TO 110°F.

NEW 2" WATER METER AND TRANSMITTER INSTALLED IN RELOCATED WATER

MAIN PIPING. PROVIDE NEW 2" BADGER WATER METER MODEL RCDL M170.

PROVIDE BADGER MODEL RTR TRANSMITTER REGISTER WITH WATER METER TO

PROVIDE DIGITAL OUTPUT CAPABLE OF COMMUNICATING WITH BUILDING DDC

SYSTEM.

PROVIDE 1" VALVED TAP WITH ENDCAP FOR FUTURE USE WITH EQUIPMENT

MOUNTED IN THIS AREA.

THE COMBINATION STROBE LIGHT AND HORN ALARM ASSEMBLY FOR

EMERGENCY EYE/FACE WASH FIXTURE SHALL BE SURFACE MOUNTED ON THE

WALL ABOVE THE EMERGENCY FIXTURE. THE ASSOCIATED FLOW SWITCH

SHALL BE INSTALLED DOWNSTREAM OF THE THERMOSTATIC MIXING VALVE

"TMV-1" IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION

INSTRUCTIONS.

A WALL MOUNTED ANSI COMPLIANT EMERGENCY FIXTURE IDENTIFICATION SIGN

SHALL BE INSTALLED ADJACENT TO THE EMERGENCY FIXTURE AS SHOWN.

AIR GAP FITTINGS CONNECTED TO THE RELIEF VALVE ASSEMBLIES OF

BACKFLOW PREVENTER "BFP-1" SHALL DRAIN INDIRECTLY INTO FLOOR DRAIN

LOCATED NEAR DHW-1. THE INDIRECT WASTE PIPING SHALL BE CONSTRUCTED

OF TYPE "L" COPPER AND HOLES (SLIGHTLY LARGER THAN THE DIAMETER OF

EACH INDIRECT WASTE PIPE).

HOT WATER RECIRCULATION LINES REQUIRE CIRCUIT SETTER SET TO 1/2 GPM

FOR EACH BRANCH. CIRCUIT SETTERS REQUIRED TO PROVIDE FLOW FROM ALL

BRANCHES OF THE RECIRCULATION SYSTEM (TYP. FOR ALL RECIRCULATION

LINES).

4'0 8' 16'

0 2' 4' 8'

0 2' 4' 8'

TRUE

NORTH

CC

EE

SHEET METAL

SHOP

A.G.E. #1

FCU-5

FCU-4

FCU-3

UH-1UH-2

MAU-1

DOAS-1

UH-3

OAP-1

FCU-1FCU-2

2 2

4FCU-6

CLEANOUT

CLEANOUT

LA

Y O U T

D R A W N

R E V

IE

W E D

D sheetsof

R E

V

IS

IO

N

D A

T E

H a n so n

N o

F ile n a m e

S c a le

D a te d

W in g

Il lin o is

A ir

N a ti o n a l G u a rd

S p ri n g fi e ld

Il lin o is

-2

H a n s o n

P ro fe s s io n a l S e rv ic e s I n c

S o u th

S ix th S tr e e t

P h o n e

(2

-2

O k la m h o m a C it y

O K

-7

N G

B I

D

IQ

C o n tr a c t

W

L

-1

-D

B ro a d w a y E x te n s io n

S u it e

P h o n e

(4

-2

C o p yr ig h t H a n so n

P ro fe ss io n a l S e rv ic e s In c

R E

P A

IR

N

D I

B U

IL

D

IN

G

P -1

S P

R

IN

G F

IE

L

D

IL

ISSUED FOR CONSTRUCTION 3 MAY 2021

S ig n e d

/1

/2

E x p ir e s

/3

/2

C U s e rs

\b ra n s \D o c u m e n ts

\1 D

H

V P v s b r a n s o n .r v t

/2

/2

: 5 :5

P

M

/0

/2

F

IR

S T

F L

O O

R C

O N

D E

N S

A T

E P

IP

IN

G N

E W

W O

R K

P L

A N

P-103

L W

B W

P

J R

F

1/8" = 1'-0"1

FIRST FLOOR CONDENSATE PIPING NEW WORK

PLAN

4'0 8' 16'

1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.

2. REFER TO DIVISION 22 SPECIFICATIONS.

3. CONDENSATE BRANCH PIPING SHALL CONNECT TO THE TOP OF THE

CONDENSATE PIPING MAIN (TYPICAL FOR ALL CONDENSATE BRANCH PIPING

CONNECTIONS).

4. CONDENSATE CONNECTION TO FAN COIL AND OAP UNITS SHALL MEET

MANUFACTURER'S REQUIREMENTS FOR DIAMETER, VERTICAL RISE AND

DISTANCE BETWEEN UNIT AND VERTICAL RISE FROM CONNECTION POINT.

5. CONTRACTOR IS RESPONSIBLE FOR VERIFYING CAPABILITY TO INSTALL

CONDENSATE PIPING PER MANUFACTURER'S REQUIREMENTS.

CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY IF ANY CONFLICTS

ARISE.

6. REFER TO H-602 FOR TEMPERATURE CONDENSATE DISCHARGE

REQUIREMENTS OF HUMIDIFIER UNITS.

7. CONTRACTOR SHALL PROVIDE CLEANOUTS WHEN PIPING CHANGES

DIRECTION GREATER THAN 45oF. CLEANOUTS TO BE PROVIDED WHETHER

THEY ARE EXPLICITLY CALLED FOR ON THE DRAWINGS OR NOT.

GENERAL SHEET NOTES

SHEET KEYNOTES

CONDENSATE PIPING SHALL INDIRECTLY DISCHARGE THROUGH THE GRATING

INSTALLED OVERTOP OF THE DEPRESSED FLOOR SLAB DEPICTED BY THE BOX.

THE CONDENSATE PIPING SHALL NOT INTERFERE WITH THE ADA CLEARANCE OF

THE ADJACENT EMEBERGENCY FIXTURE. PIPING SHOWN AS SEPARATE

DISCHARGES FOR CLARITY. AS FIELD CONDITIONS ALLOW, CONDENSATE PIPING

SHALL BE COMBINED PRIOR TO DISCHARGE TO LIMIT NUMBER OF

PENETRATIONS THROUGH GRATING.

CONDENSING GAS-FIRED UNIT HEATER (BY HEATING CONTRACTOR) SHALL BE

PROVIDED WITH CONDENSATE NEUTRALIZER KIT. INSTALL THE NEUTRALIZING

PER MANUFACTURER'S RECOMMENDATIONS.

CONDENSATE PIPING DOWN BELOW MEZZANINE, ROUTE PIPING AS HIGH AS

POSSIBLE BELOW THE MEZZANINE OVER TO THE EMERGENCY EYEWASH FOR

DISCHARGE. COORDINATE MOUNTING HEIGHT OF CONDENSATE PIPING WITH

OTHER BRANCHES TYING INTO PIPING.

WALL MOUNTED FAN COIL UNIT TO BE PROVIDED WITH EXTERNAL CONDENSATE

PUMP. EXTERNAL CONDENSATE PUMP SHALL BE MOUNTED ADJACENT TO THE

ASSOCIATED FAN COIL.

CONDENSATE PIPING SHALL INDIRECTLY DISCHARGE THROUGH TO THE FLOOR

DRAIN LOCATED NEAR THE DOMESTIC WATER HEATER. PIPING SHOWN AS

SEPARATE DISCHARGES FOR CLARITY. AS FIELD CONDITIONS ALLOW,

CONDENSATE PIPING SHALL BE COMBINED PRIOR TO DISCHARGE TO LIMIT

NUMBER OF PIPES AT FLOOR DRAIN.

TRUE

NORTH

A

B

C

D

E

1 2 3 4 5 6 7 8

1 1/2" CA

1 1/2" CA1 1/2" CA

1 1/2" CA

1 1/2" CA

1 1/2" CA

1 1/2" CA

1 1/2" CA

1 1/2" CA

1/2" CA

3/4" CA1/2" CA

1/2" CA

1/2" CA

1/2" CA

3/4" CA

1/2" CA1/2" CA

1/2" CA

1/2" CA

1/2" CA

1/2" CA

1/2" CA

1" CA

1" CA

3/4" CA

1/2" CA

1/2" CA

HOSE REELS

HOSE REELS

HOSE REELS

AC-1 AC-2

LA

Y O U T

D R A W N

R E V

IE

W E D

D sheetsof

R E

V

IS

IO

N

D A

T E

H a n so n

N o

F ile n a m e

S c a le

D a te d

W in g

Il lin o is

A ir

N a ti o n a l G u a rd

S p ri n g fi e ld

Il lin o is

-2

H a n s o n

P ro fe s s io n a l S e rv ic e s I n c

S o u th

S ix th S tr e e t

P h o n e

(2

-2

O k la m h o m a C it y

O K

-7

N G

B I

D

IQ

C o n tr a c t

W

L

-1

-D

B ro a d w a y E x te n s io n

S u it e

P h o n e

(4

-2

C o p yr ig h t H a n so n

P ro fe ss io n a l S e rv ic e s In c

R E

P A

IR

N

D I

B U

IL

D

IN

G

P -1

S P

R

IN

G F

IE

L

D

IL

ISSUED FOR CONSTRUCTION 3 MAY 2021

S ig n e d

/1

/2

E x p ir e s

/3

/2

C U s e rs

\b ra n s \D o c u m e n ts

\1 D

H

V P v s b r a n s o n .r v t

/2

/2

: 5 :5

P

M

/0

/2

F

IR

S T

F L

O O

R C

O M

P R

E S

S E

D A

IR

P

IP

IN

G N

E W

W O

R K

P L

A N

P-104

L W

B W

P

J R

F

1/8" = 1'-0"1

FIRST FLOOR COMPRESSED AIR PIPING NEW

WORK PLAN

1/4" = 1'-0"2

ENLARGED MECHANICAL ROOM COMPRESSED

AIR PIPING NEW WORK PLAN

1. REFER TO PLUMBING GENERAL NOTES ON SHEET P-001.

2. REFER TO DIVISION 22 SPECIFICATIONS.

3. THE COMPRESSED AIR PIPING ACCESSORIES SHALL BE INSTALLED WITH THE

THEIR MANUFACTURER'S RECOMMENDED STRAIGHT LENGTH OF PIPE

UPSTREAM AND DOWNSTREAM OF THE PIPING ACCESSORY.

GENERAL SHEET NOTES

SHEET KEYNOTES

AIR COMPRESSORS AC-1 & AC-2. AT A MINIMUM, THE AIR COMPRESSOR

MANUFACTURER'S SERVICE CLEARANCE REQUIREMENTS SHALL BE

MAINTAINED. AC-1 SHALL BE THE EXISTING, SALVAGED, AIR COMPRESSOR TO

BE RE-INSTALLED. AC-2 SHALL BE GFCI FOR FURTURE DUST/PAINT BOOTHS.

1" FLEXIBLE CONNECTOR (SPECIFIED IN THE AIR COMPRESSOR SCHEDULE ON

SHEET P-602).

EXTRA FINE PARTICULATE AND COALESCING INLINE FILTER (SPECIFIED IN THE

AIR COMPRESSOR SCHEDULE ON SHEET P-602).

PRESSURE GAUGE.

AIR MAIN CHARGING VALVE (SPECIFIED IN THE AIR COMPRESSOR SCHEDULE ON

SHEET P-602).

PILOT LINE FOR AIR MAIN CHARGING VALVE (ESTIMATED LINE SIZE 3/8"). PILOT

LINE SHALL BE CONSTRUCTED OF SOFT COPPER.

1" BYPASS LINE HAS BEEN SHOWN IN THE HORIZONTAL PLANE FOR DRAWING

CLARITY HOWEVER, THE BYPASS LINE SHALL BE INSTALLED VERTICALLY

AGAINST THE WALL SURFACE SO AS NOT TO INTERFERE WITH THE AIR

COMPRESSOR'S SERVICE CLEARANCE.

PRESSURE TRANSDUCER PROVIDED AND INSTALLED BY ALPHA CONTROLS

(ALPHA CONTROLS WILL BE A SUBCONTRACTOR OF THE PROJECT VENTILATION

CONTRACTOR. ALPHA CONTROLS CONTACT INFORMATION: JEFF MILLER,

1-866-257-4201). PLUMBING CONTRACTOR SHALL COORDINATE WITH ALPHA

CONTROLS SO THAT THE APPROPRIATE FITTINGS ARE INSTALLED IN THE

COMPRESSED AIR PIPING SYSTEM TO ACCOMMODATE INSTALLATION OF THE

PRESSURE TRANSDUCER.

NOT USED.

1/2" TYPE L COPPER SHALL BE ATTACHED TO THE 1/4" CONDENSATE DRAIN

CONNECTION ON THE AIR COMPRESSOR'S INTEGRAL COMPRESSED AIR

RECEIVER TANK.

APPROXIMATE INSTALLATION LOCATION OF THE ELECTRONIC DEMAND TYPE

AUTOMATIC CONDENSATE DRAIN (SPECIFIED IN THE AIR COMPRESSOR

SCHEDULE ON SHEET P-602). THE CONDENSATE DRAIN SHALL BE INSTALLED IN

A SERVICEABLE LOCATION.

CONDENSATE PIPING CONNECTED TO THE 1/4" DISCHARGE CONNECTION ON

THE AUTOMATIC CONDENSATE DRAIN SHALL BE 1/2" TYPE L COPPER.

CONDENSATE PIPING SHALL DISCHARGE INDIRECTLY INTO THE NEARBY FLOOR

DRAIN. ROUTE ALONG WALLS TO PROVIDE CLEAR WALKING SPACE AS FIELD

CONDITIONS ALLOW.

CONNECT 1/2" TYPE L COPPER TO THE CONDENSATE DISCHARGE CONNECTION

ON THE EXTRA FINE PARTICULATE AND COALESCING INLINE FILTER.

CONDENSATE DISCHARGE CONNECTION SIZE ON THE EXTRA FINE PARTICULATE

AND COALESCING INLINE FILTER IS ESTIMATED TO BE 1/4". CONDENSATE PIPING

SHALL DISCHARGE INDIRECTLY INTO THE NEARBY FLOOR DRAIN. ROUTE ALONG

WALLS TO PROVIDE CLEAR WALKING SPACE AS FIELD CONDITIONS ALLOW.

PROVIDE 3/4" TAPS WITH VALVE AND ENDCAP FOR CONNECTION TO FUTURE

PAINT / DUST BOOTHS.

PIPING AND ACCESSORIES ONLY SHOWN FOR SINGLE PACKAGED COMPRESSOR

FOR CLARITY. BOTH PACKAGED COMPRESSORS SHALL RECIEVE ALL PIPING

AND ACCESSORIES NOTED ON THIS SHEET. DESIGN INTENT IS FOR PIPING AND

ACCESSORIES TO MOUNTED ALONG THE NORTH WALL IN A STACKED

ORIENTATION AS FIELD CONDTIONS ALLOW.

4'0 8' 16'

0 2' 4' 8'

TRUE

NORTH

PIPE INSULATION (TYP.)

THREADED ROD (TYP.)

UNI-STRUT OR EQUIVALENTINSULATION SHIELD (TYP.)

INSTALL CLAMP ON ALL PIPES

LESS THAN 4"

FIBERGLASS PIPE

INSULATION

PIPE

HIGH DENSITY INSULATION

SADDLE (HOT WATER PIPING

ONLY)

HARDWOOD INSULATION

SADDLE (CHILLED WATER

PIPING ONLY)

SUPPORT CLEVIS HANGER

16 GA. GALV. STEEL

INSULATION SHIELD WITH

FLARED ENDS

ALL SERVICE JACKET ON

PIPE INSULATION

NOMINAL INNER DIAMETER

OF INSULATION SHIELD (IN.)

SHIELD

LENGTH

(IN.)

2 3/8" TO 6 5/8" 12

7 5/8" TO 20" 18

CLEANOUT TO FLOOR (FCO)CLEAN OUT TO GRADE (YCO)

DOUBLE TEE TYPE

1/8 C.I. BEND

FLOOR LINE

SANITARY SEWER LINE

1/8 BEND IF CLEANOUT

OCCURS AT END OF LINE

C.I. WASTE LINE

LENGTH TO SUIT

CLEANOUT WITH STAINLESS STEEL OR

NICKLE BRONZE COVER AND BRONZE PLUG.

TOP OF COVER TO BE FLUSH w/TOP OF

FLOOR AND COMPATIBLE WITH FLOOR

MATERIAL

TWO-WAY CLEANOUT TEE

FLOOR LINE

CLEANOUT WITH STAINLESS

STEEL COVER AND BRONZE

PLUG. TOP OF COVER TO BE

FLUSH w/TOP OF FLOOR AND

COMPATIBLE WITH FLOOR

MATERIAL

SANITARY SEWER LINE SANITARY SEWER LINE SANITARY SEWER LINE

3" SOCKET x MPT

PVC ADAPTER

CRUSHED LIMESTONE

(1/2 - 3/4 GALLON)

3"x24" SCH. 40

PVC PIPE

3" FPT PVC CAP, 3/4"

FPT TAP ON END

3/4" MPT BARBED

FITTING

SINGULAR OR

COMBINED

DRAIN FROM

EQUIPMENT

TO FLOOR DRAIN,

REFER TO PLANS

3/4" MPT BARBED

FITTING

1/2" MESH STAINLESS

STEEL SCREEN

3" FPT PVC CAP, 3/4"

FPT TAP ON END

1/2" MESH STAINLESS

STEEL SCREEN

CONTRACTOR TO PROVIDE CONDENSATE

NEUTRALIZERS AS REQUIRED PER

EQUIPMENT INSTALLATION. REFER TO

PLANS FOR NEUTRALIZER LOCATIONS

COMBUSTION

AIR INLET SEAL WITH HIGH

TEMPERATURE SILICONE

PER MANUFACTURERS

REQUIREMENTS

5'-0" MAX.M

IN

ROOF

FLASHING

SIZE VARIES

GAS-FIRED

EQUIPMENT

SIZE VARIES

CONCENTRIC

ADAPTER BOX

M

IN

VENT (FLUE EXHAUST)

PIPE

VENT (FLUE EXHAUST)

TERMINAL

140° HW SUPPLY

HWR

AQUASTAT SENSOR

CP-1

DWH-1

ET-1

T

SET VARIABLE SPEED PUMP TO

MAINTAIN 125° TEMPERATURE IN THE

DOMESTIC HOT WATER RETURN LINE

PIPE RELIEF VALVE

TO FLOOR DRAIN

NEARBY (TYP.)

CW SUPPLY

ROUTE TO NEAREST

FLOOR DRAIN

IN-LINE

RECIRCULATING

PUMP

SHUT-OFF

VALVE (TYP.)

CHECK

VALVE

"Y" STRAINER

CONDENSATE NEUTRALIZER

AS REQUIRED BY MFG.

LA

Y O U T

D R A W N

R E V

IE

W E D

D sheetsof

R E

V

IS

IO

N

D A

T E

H a n so n

N o

F ile n a m e

S c a le

D a te d

W in g

Il lin o is

A ir

N a ti o n a l G u a rd

S p ri n g fi e ld

Il lin o is

-2

H a n s o n

P ro fe s s io n a l S e rv ic e s I n c

S o u th S ix th

S tr e e t

P h o n e

(2

-2

O k la m h o m a C it y

O K

-7

N G

B I

D

IQ

C o n tr a c t

W

L

-1

-D

B ro a d w a y E x te n s io n

S u it e

P h o n e

(4

-2

C o p yr ig h t H a n so n

P ro fe ss io n a l S e rv ic e s In c

R E

P A

IR

N

D I

B U

IL

D

IN

G

P -1

S P

R

IN

G F

IE

L

D

IL

ISSUED FOR CONSTRUCTION 3 MAY 2021

S ig n e d

/1

/2

E x p ir e s

/3

/2

C U s e rs

\b ra n s \D o c u m e n ts

\1 D

H

V P v s b r a n s o n .r v t

/2

/2

: 5 :5

P

M

/0

/2

P L

U M

B

IN

G D

E T

A

IL

S

P-501

L W

B W

P

J R

F

NOT TO SCALE1

INSULATED PIPES SUPPORT DETAIL

NOT TO SCALE2

INSULATED PIPE SUPPORT DETAIL

NOT TO SCALE3

FLOOR CLEANOUT

NOT TO SCALE4

CONDENSATE NEUTRALIZER

NOT TO SCALE6

SEPARATED VENT/INLET AIR AND CONCENTRIC

ADAPTER

NOT TO SCALE5

DOMESTIC WATER HEATER PIPING DETAIL

LA

Y O U T

D R A W N

R E V

IE

W E D

D sheetsof

R E

V

IS

IO

N

D A

T E

H a n so n

N o

F ile n a m e

S c a le

D a te d

W in g

Il lin o is

A ir

N a ti o n a l G u a rd

S p ri n g fi e ld

Il lin o is

-2

H a n s o n

P ro fe s s io n a l S e rv ic e s I n c

S o u th

S ix th S tr e e t

P h o n e

(2

-2

O k la m h o m a C it y

O K

-7

N G

B I

D

IQ

C o n tr a c t

W

L

-1

-D

B ro a d w a y E x te n s io n

S u it e

P h o n e

(4

-2

C o p yr ig h t H a n so n

P ro fe ss io n a l S e rv ic e s In c

R E

P A

IR

N

D I

B U

IL

D

IN

G

P -1

S P

R

IN

G F

IE

L

D

IL

ISSUED FOR CONSTRUCTION 3 MAY 2021

S ig n e d

/1

/2

E x p ir e s

/3

/2

C U s e rs

\b ra n s \D o c u m e n ts

\1 D

H

V P v s b r a n s o n .r v t

/2

/2

: 5 :5

P

M

/0

/2

P L

U M

B

IN

G S

C H

E D

U L

E S

P-601

L W

B W

P

J R

F

NOTE: MANUFACTURER(S) AND MODEL(S) SHOWN ARE BASIS OF DESIGN, REFER TO CORRESPONDING SPECIFICATION SECTION FOR SALIENT CHARACTERISTIC AND OTHER ACCEPTABLE MANUFACTURERS.

WHA-1

STAINLESS STEEL WATER HAMMER ARRESTOR, NESTING BELLOWS TYPE - ZURN

MODEL NO. Z1700

1. REFER TO PLUMBING SHEET P-602 FOR WATER HAMMER

ARRESTOR SIZES.

2. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS

AND ALTERNATIVE MANUFACTURERS.

YCO-1

CAST IRON BODY YARD CLEANOUT WITH GAS AND WATERTIGHT TAPERED THREAD

BRONZE PLUG AND NO-HUB CONNECTION - ZURN MODEL NO. Z1440

1. CAST IRON BODY HEAVY DUTY CLEANOUT HOUSING WITH INTEGRAL ANCHOR FLANGE AND SCORIATED CAST IRON

COVER WITH LIFTING DEVICE - ZURN MODEL NO. Z1474

6"

1. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS

AND ALTERNATIVE MANUFACTURERS.

SHOWER VALVE: POWERS MODEL NO. E425,

LAWLER MODEL NO. 3800, LEONARD MODEL

NO. 7600

SINGLE HANDLE THERMOSTATIC MIXING FAUCET, BRASS OR BRONZE CONSTRUCTION,

WASHERLESS DESIGN, OFF-COLD-HOT TEMPERATURE RANGE INDICATOR DIAL, POLISHED CHROME CAST METAL LEVER HANDLE, INTEGRAL

CHECK-STOPS, ADJUSTABLE SAFETY LIMIT STOP, ADJUSTABLE SPRAY HANDHELD SHOWER WITH 60" CHROME-PLATED METAL HOSE, CHROME-PLATED BRASS SWIVEL CONNECTOR, 24" CHROME-PLATED MOUNTING RAIL, CHROME-PLATED BRASS SUPPLY ELBOW WITH FLANGE, CHROME-PLATED IN-LINE VACUUM BREAKER WITH CHROME-PLATED PIPING AND FLANGES, ASSE 1016 LISTED. 1.5 GPM FLOWRATE.

SHOWERHEAD: POWERS MODEL NO. H w/ E425, LAWLER MODEL NO. HS3 w/ 3800, LEONARD MODEL NO. 62001-1.5 w/ 7600. REFER TO

SPECIFICATION 224223

SH-1

ADA SHOWER BASIN AND

SHOWER FAUCET

BASIN: FIAT MODEL NO. MFT, CREATIVE

INDUSTRIES MODEL NO. 74832, WILLIAMS

MODEL NO. 56, FLORESTONE

ROOL-IN SHOWER BASE, 64"x32", 2" DRAIN, STAINLESS STEEL REMOVABLE STRAINER, REFER TO SPECIFICATION 224223

2" 2" 2" 1/2" 1/2"

INSTALL ALL CONTROLS BETWEEN 38" AND 48"

ABOVE FINISHED FLOOR IN COMPLIANCE WITH ADA

SECTION 4.21. SET SAFETY LIMIT STOP TO 110°F

DISCHARGE.

WC-1

WHITE VITREOUS CHINA WALL HUNG LAVATORY, ADA COMPLIANT, 20"L x 18"W

NOMINAL DIMENSIONS, BOWL AREA OVERFLOW, 4" CENTERSET FAUCET HOLES,

DRILLED FOR CONCEALED ARM CARRIER - KOHLER MODEL NO. K-2032

1. MANUALLY OPERATED, EXPOSED DIAPHRAGM TYPE FLUSHOMETER CONSTRUCTED OF POLISHED CHROME PLATED

BRASS. 1-1/2" TOP SPUD CONNECTION WITH ADA COMPLIANT NON-HOLD OPEN HANDLE, 1.28 GPF, INTERNAL RUBBER COMPONENTS TO BE CHLORAMINE RESISTANT AND DUAL FILTERED FIXED METERING BYPASS -

SLOAN MODEL NO. ROYAL 111-1.28

2. ADJUSTABLE VERTICAL BACK-TO-BACK SIPHON JET 4" NO-HUB WATER CLOSET FIXTURE CARRIER WITH HIGH

PERFORMANCE WATERWAY FOR LOW-FLOW FIXTURES. FIXTURE CARRIER SHALL HAVE A MINIMUM STATIC LOAD

RATING OF 500 LBS - ZURN MODEL NO. Z1202-ND4

3. ELONGATED OPEN FRONT (LESS COVER) WHITE COLORED ANTIMICROBIAL HEAVY-DUTY SOLID PLASTIC TOILET

SEAT WITH MOLDED-IN BUMPERS AND NON-SELF SUSTAINING CHECK HINGES WITH 300 SERIES STAINLESS

STEEL POSTS AND PINTLES - CHURCH SEATS MODEL NO. 2155CT.

4" - 2" 1" -

1. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS

AND ALTERNATIVE MANUFACTURERS.

2. THE FINISHED SURFACE TO FINISHED SURFACE WIDTH/DEPTH

DIMENSION OF THE LATRINES' PLUMBING CHASE WALL IS 2'-3".

PLUMBING CONTRACTOR SHALL PROVIDE WATER CLOSET

FIXTURE CARRIER COUPLING LENGTHS, AUXILIARY FOOT

SUPPORTS AND ATTACHMENT HARDWARE AS REQUIRED TO BE

COMPATIBLE WITH THIS DIMENSION.

3. FLUSHOMETER HANDLE SHALL BE INSTALLED SUCH THAT IT IS

ON THE WIDE SIDE OF THE LATRINE STALL ENCLOSURE.

UR-1

WHITE VITREOUS CHINA WALL HUNG URINAL, ADA COMPLIANT, WASHOUT STYLE,

0.125 GPF AND 3/4" TOP SPUD - KOHLER MODEL NO. K-4991-ET

1. MANUALLY OPERATED, EXPOSED DIAPHRAGM TYPE FLUSHOMETER CONSTRUCTED OF POLISHED CHROME PLATED

BRASS. 3/4" TOP SPUD CONNECTION WITH ADA COMPLIANT NON-HOLD OPEN HANDLE, 0.125 GPF, INTERNAL RUBBER COMPONENTS TO BE CHLORAMINE RESISTANT AND DUAL FILTERED FIXED METERING BYPASS -

SLOAN MODEL NO. ROYAL 186-0.125-DBP

2. PLATE TYPE URINAL FIXTURE CARRIER WITH RECTANGULAR STEEL UPRIGHTS WELDED TO FLOOR MOUNTED

FEET - ZURN MODEL NO. Z1221

2" - 2" 3/4" -

1. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS

AND ALTERNATIVE MANUFACTURERS.

TD-2

POLYPROPYLENE PRE-SLOPED 6" WIDE TRENCH DRAIN SYSTEM, POLYPROPYLENE

GRATE FRAME, REINFORCED STAINLESS STEEL SLOTTED GRATE (ADA COMPLIANT

& HEEL PROOF), STAINLESS STEEL FRAME GUARDS (INSTALLED OVERTOP OF

POLYPROPYLENE GRATE FRAME), LOAD CLASS E / ANSI CLASS XHD WITH

STAINLESS STEEL FRAME GUARDS INSTALLED, NO-HUB BOTTOM OUTLET - WATTS

MODEL NO. DEAD-LEVEL "P"

- 4" DEEP SEAL TRAP 2" - -

1. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS

AND ALTERNATIVE MANUFACTURERS.

TD-1

LOW PROFILE LINEAR FLOOR DRAIN WITH PRE-SLOPED DRAIN TRAY, STAINLESS

STEEL FRAME AND GRATE (ADA COMPLIANT & HEEL PROOF), NO-HUB BOTTOM

OUTLET - SCHLUTER MODEL NO. KERDI-LINE w/ KERDI-SHOWER-LT

- 4" DEEP SEAL TRAP 2" - -

1. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS

AND ALTERNATIVE MANUFACTURERS.

S-2

SINK - STAINLESS STEEL, WALL HUNG, SINGLE COMPARTMENT, 31"W x 19.5"D

OVERAL SIZE, 10.5" BOWL DEPTH. REMOVABLE STAINLESS STEEL BASKET STRAINER

WITH NEOPRENE STOPPER. 8" ON CENTER FAUCET - ELKAY MODEL NO.

EWS3120W4C

1. 8" SWING GOOSNECK SPOUT, WALL MOUNT, SWIVEL SPOUT, WRIST HANDLES, SUPPLIES AT 8" (ADJ.) CENTERS, MAXIMUM FLOW TO BE 1.5

GPM - CHICAGO FAUCETS MODEL 631-GN8AE35ABCP

2. TYPE 304 STAINLESS STEEL BODY AND REMOVABLE CONICAL BASKET STRAINER WITH METAL STEM AND STOPPER

FOR 3-1/2" OPENING. CHROME PLATED LEVER ARM FOR DRAINAGE CONTROL AND 1-1/2" x 4" TYPE 304

STAINLESS STEEL TAILPIECE - ELKAY MODEL NO. LK27

3. CHROME PLATED BRASS 1-1/2" P-TRAP (17 GAUGE BRASS TUBE CONSTRUCTION), CHROME PLATED BRASS

ANGLE STOPS (SHUT-OFF HANDLE STYLE), CHROME PLATED BRASS ESCUTCHEONS AND CHROME PLATED

COPPER/BRASS RIGID SUPPLY RISERS.

4. POINT OF USE THERMOSTATIC MIXING VALVE "TMV-2" AS IDENTIFIED IN THE THERMOSTATIC MIXING VALVE

SCHEDULE ON P-602.

1-1/2" 1-1/2" 1-1/2" 1/2" 1/2"

1. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS

AND ALTERNATIVE MANUFACTURERS.

S-1

SINK - STAINLESS STEEL, DECK MOUNT, DUAL COMPARTMENT, 33"W x 22"D

OVERAL SIZE, 9" BOWL DEPTH. REMOVABLE STAINLESS STEEL BASKET STRAINER

WITH NEOPRENE STOPPER. 8" ON CENTER FAUCET - KOHLER MODEL NO. K-5267-4.

1. 8" SWING GOOSENECK SPOUT, DECK MOUNT, 2-3/8" LEVER HANDLES, SUPPLIES AT 8" CENTERS, SPRAY HOSE WITH LEVER CONTROL, MAXIMUM FLOW TO BE 1.5 GPM - CHICAGO FAUCETS MODEL NO. 1102-GN8AE35-369AB

2. TYPE 304 STAINLESS STEEL BODY AND REMOVABLE CONICAL BASKET STRAINER WITH METAL STEM AND STOPPER

FOR 3-1/2" OPENING. CHROME PLATED LEVER ARM FOR DRAINAGE CONTROL AND 1-1/2" x 4" TYPE 304

STAINLESS STEEL TAILPIECE - ELKAY MODEL NO. LK27

3. CHROME PLATED BRASS 1-1/2" P-TRAP (17 GAUGE BRASS TUBE CONSTRUCTION), CHROME PLATED BRASS

ANGLE STOPS (SHUT-OFF HANDLE STYLE), CHROME PLATED BRASS ESCUTCHEONS AND CHROME PLATED

COPPER/BRASS RIGID SUPPLY RISERS.

4. POINT OF USE THERMOSTATIC MIXING VALVE "TMV-2" AS IDENTIFIED IN THE THERMOSTATIC MIXING VALVE

SCHEDULE ON P-602.

1-1/2" 1-1/2" 1-1/2" 1/2" 1/2"

1. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS

AND ALTERNATIVE MANUFACTURERS.

LAV-1

WHITE VITREOUS CHINA WALL HUNG LAVATORY, ADA COMPLIANT, 20"L x 18"W

NOMINAL DIMENSIONS, BOWL AREA OVERFLOW, 4" CENTERSET FAUCET HOLES,

DRILLED FOR CONCEALED ARM CARRIER - KOHLER MODEL NO. K-2032

1. DECK MOUNTED 4" FIXED CENTERS SINGLE LEVER HOT AND COLD WATER LAVATORY FAUCET CONSTRUCTED OF

POLISHED CHROME PLATED LOW-LEAD CAST BRASS WITH AN INTEGRAL ASSE 1070 CERTIFIED THERMOSTATIC

MIXING CARTRIDGE. ADA COMPLIANT, 4-5/8" RIGID SPOUT AND 0.5 GPM FLOW RATE - CHICAGO FAUCETS

MODEL NO. 420-T45E2805ABCP

2. POLISHED CHROME PLATED BRASS GRID STRAINER FOR USE IN OVERFLOW APPLICATIONS - KOHLER MODEL NO.

K-7129-A.

3. CHROME PLATED BRASS 1-1/4" P-TRAP (17 GAUGE BRASS TUBE CONSTRUCTION), CHROME PLATED BRASS

ANGLE STOPS (SHUT-OFF HANDLE STYLE), CHROME PLATED BRASS ESCUTCHEONS, CHROME PLATED

COPPER/BRASS RIGID SUPPLY RISERS AND WHITE COLORED ADA COMPLAINT UNDERSINK PIPE COVERS FOR

P-TRAP, ANGLE VALVES AND SUPPLY RISERS.

4. CONCEALED ARM LAVATORY FIXTURE CARRIER WITH RECTANGULAR STEEL UPRIGHTS WELDED TO FLOOR MOUNTED

FEET - ZURN MODEL NO. Z1231. POINT OF USE THERMOSTATIC MIXING VALVE "TMV-1" AS IDENTIFIED IN THE THERMOSTATIC MIXING VALVE

SCHEDULE ON P-602.

2" 1-1/4" 2" 1/2" 1/2"

1. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS

AND ALTERNATIVE MANUFACTURERS.

FD-1

CAST IRON BODY FLOOR DRAIN WITH 7"Ø ROUND LIGHT DUTY POLISHED NICKEL

BRONZE TOP, COMBINATION INVERTIBLE MEMBRANE CLAMP AND ADJUSTABLE

COLLAR WITH SEEPAGE SLOTS AND NO-HUB CONNECTION - ZURN MODEL NO.

Z415B

1. DEEP SEAL CAST IRON P-TRAP 3" 2"

1. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS

AND ALTERNATIVE MANUFACTURERS.

FCO-1

CAST IRON BODY ADJUSTABLE FLOOR CLEANOUT WITH GAS AND WATERTIGHT

TAPERED THREAD BRONZE PLUG, ROUND EXTRA HEAVY DUTY SCORIATED

POLISHED NICKEL BRONZE TOP, ANCHOR FLANGE AND NO-HUB CONNECTION -

ZURN MODEL NO. Z1400

- 4"

1. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS

AND ALTERNATIVE MANUFACTURERS.

WASTE TRAP VENT COLD WATER HOT WATER

PLUMBING FIXTURE/EQUIPMENT TAG PLUMBING FIXRURE DESCRIPTION PLUMBING FIXTURE ACCESSORIES

PLUMBING FIXTURE UTILITY CONNECTIONS (MINIMUM SIZE)

REMARKS

PLUMBING FIXTURE & EQUIPMENT SCHEDULE

/2

/2

A D

D E

N D

A N

O

O U T

D R A W N

R E V

IE

W E D

D sheetsof

R E

V

IS

IO

N

D A

T E

H a n so n

N o

F ile n a m e

S c a le

D a te d

W in g

Il lin o is

A ir

N a ti o n a l G u a rd

S p ri n g fi e ld

Il lin o is

-2

H a n s o n

P ro fe s s io n a l S e rv ic e s I n c

S o u th

S ix th S tr e e t

P h o n e

(2

-2

O k la m h o m a C it y

O K

-7

N G

B I

D

IQ

C o n tr a c t

W

L

-1

-D

B ro a d w a y E x te n s io n

S u it e

P h o n e

(4

-2

C o p yr ig h t H a n so n

P ro fe ss io n a l S e rv ic e s In c

R E

P A

IR

N

D I

B U

IL

D

IN

G

P -1

S P

R

IN

G F

IE

L

D

IL

ISSUED FOR CONSTRUCTION 3 MAY 2021

S ig n e d

/1

/2

E x p ir e s

/3

/2

C U s e rs

\b ra n s \D o c u m e n ts

\1 D

H

V P v s b r a n s o n .r v t

/2

/2

: 5 :5

P

M

/0

/2

P L

U M

B

IN

G S

C H

E D

U L

E S

C O

N T

IN

U

E D

P-602

L W

B W

P

J R

F

1. EMERGENCY FIXTURE SHOWER HEAD SUPPLY ARM PIPING SHALL BE 3'-0" IN LENGTH (SIMILAR TO

SPECIFICATION. THE INTENT IS FOR THE SHOWER HEAD TO BE CENTERED OVERTOP OF THE

DEPRESSED FLOOR SLAB AND GRATING INSTALLED DIRECTLY ADJACENT TO THE

EMERGENCY FIXTURE (AS IDENTIFIED IN KEYED NOTE #8 ON SHEET 106) TO MINIMIZE WASTE WATER

RUNOFF FROM THE EMERGENCY FIXTURE

2. THERMOSTATIC MIXING VALVE (TMV-1) AS LISTED IN THE THERMOSTATIC

MIXING VALVE SCHEDULE ON THIS SHEET SHALL BE USED FOR THIS

EMERGENCY FIXTURE.

3. REFER TO SPECIFICATION SECTION 224500 FOR ADDITIONAL EMERGENCY

FIXTURE REQUIREMENTS AND ALTERNATIVE MANUFACTURERS.

REMARKS:

1. ANSI COMPLIANT IDENTIFICATION SIGN.

2. STAINLESS STEEL COVER FOR EYE/FACE WASH BOWL.

3. POWDER COATED YELLOW FINISH ON GALVANIZED PIPE AND FITTINGS.

4. WEATHER PROOF COMBINATION STROBE LIGHT AND ALARM HORN

ASSEMBLY WITH WATERPROOF FLOW SWITCH (GUARDIAN MODEL NO.

AP275-705). AUDIO VISUAL ALARM SHALL INCLUDE A SILENCING SWITCH

FOR ALARM HORN AND THE FLOW SWITCH SHALL BE DOUBLE POLE,

DOUBLE THROW FOR CONNECTION TO THE FIRE ALARM SYSTEM. THE A/V

DEVICE SHALL ALSO INCLUDE A CORROSION RESISTANT SURFACE BOX AND

HARDWARE FOR MOUNTING THE AUDIO VISUAL ALARM ON THE EMERGENCY FIXTURE

ACCESSORIES:

REMARKS 1, 2, 3

ACCESSORIES 1, 2, 3, 4

SHOWER HEAD STAINLESS STEEL

EYE/FACE WASH

GPM (MIN) 3

SHOWER HEAD IMPACT RESISTANT PLASTIC

DRENCH

SHOWER

GPM (MIN) 20

ADA COMPLIANT YES

FROST-PROOF NO

MATERIAL OF CONSTRUCTION GALVANIZED STEEL

TYPE FREE STANDING

MODEL NO. GBF1909

MANUFACTURER GUARDIAN

EQUIPMENT TAG ESEFW-1

EMERGENCY EYE/FACE WASH FIXTURE SCHEDULE

TMV-2 0.25 12 1/2" 1/2"

POINT OF USE THERMOSTATIC MIXING VALVE, BRONZE BODY (LOW LEAD), LOCKING TEMPERATURE REGULATOR, COPPER/STAINLESS STEEL INTERNAL PARTS, INTEGRAL CHECK VALVES ON HOT AND COLD INLETS, MOUNTING BRACKET, ROUGH BRONZE OR CHROME PLATED FINISH, RATER FOR 0.25 GPM MINIMUM

FLOW, ASSE 1070 CERTIFIED - LEONARD MODEL NO. 270-LF.

REFER TO SPECIFICATIONS FOR ADDITIONAL

REQUIREMENTS AND ALTERNATIVE

MANUFACTURERS.

TMV-1 3 44 1" 1-1/4"

THERMOSTATIC MIXING VALVE, BRONZE BODY (LEAD FREE), LOCKING TEMPERATURE REGULATOR SET FOR 85°F WITH HIGH TEMPERATURE LIMIT STOP SET

FOR 90°F, UNION ANGLE CHECKSTOPS WITH INTEGRAL WATER STRAINER ON HOT AND COLD INLETS, SOLID BIMETALLIC THERMOSTAT CAPABLE OF

COMPENSATING FOR SUPPLY TEMPERATURE AND PRESSURE FLUCTUATIONS, 20 GPM (AT 30 PSI) COLD WATER BYPASS, INTEGRAL WALL SUPPORT, DIAL

THERMOMETER OUTLET, ASSE 1071 CERTIFIED. GUARDIAN MODEL NO. G3800LF.

REFER TO SPECIFICATIONS FOR ADDITIONAL

REQUIREMENTS AND ALTERNATIVE

MANUFACTURERS.

EQUIPMENT

TAG

MIN. FLOW

(GPM)

MAX FLOW

(GPM)

INLET SIZES

(IN.)

OUTLET

SIZES (IN.)

THERMOSTATIC MIXING VALVE DESCRIPTION REMARKS

THERMOSTATIC MIXING VALVE SCHEDULE

3. SUBJECT TO COMPLIANCE WITH THE REQUREMENTS, ACCEPTABLE MANUFACTURERS INCLUDE ROCKFORD, HIGHLAND TANK, JAY R. SMITH, WATTS.

2. PROVIDE UNIT WITH THE REQUIRED MANWAY HEIGHT TO ALLOW FOR THE TOP OF THE UNIT TO BE MOUNTED FLUSH WITH THE TOP OF THE FLOOR.

1. PROVIDE 120V/1PH NEMA 4X ALARM PANEL. ALARM PANEL SHALL HAVE INDICATING LIGHTS FOR NORMAL OPERATION, LEAK ALARMA AND HIGH OIL ALARM. PUSH BUTTONS OR SWITCHES FOR LEAK ALARM TEST, HIGH OIL ALARM TEST AND ALARM SILENCE.

PROVIDE WITH AUDIBLE ALARM HORN. PROVIDE AUXILIARY CONTACTS FOR COMMUNICATING ALARM SIGNALS TO FACILITY-WIDE MONITORING STATION. CONTROLLER SHALL BE INTRINSICALLY SAFE.

ACCESSORIES:

OWS-1 ROCKFORD ROI-150 150 4 3

ALL WELDED STEEL GRAVITY OIL/ SEDIMENT INTERCEPTOR, REMOVABLE 3/8" NONSKID TREAD PLATE COVER FOR FLUSH WITH

GRADE INSTALLATION SUITABLE FOR HEAVY TRAFFIC LOAD…