B5008 - Patio Improvements_Rev 2.pptx

PPTX presentation 224 KB Posted

Attached to
Bldg 5008 Patio Additions
Solicitation number
W50S7S25Q0003
Issued by

About this file

This PowerPoint file outlines construction requirements for patio improvements to Building 5008, detailing both base bid requirements and optional additions. The base bid includes installation of a 40'x22' lean-to style roof connecting to the building and brick wall, construction of a CMU wall with brick exterior to replace 18 feet of wrought iron fencing, installation of two 120V exterior electrical outlets, and filling approximately 70 feet of holes from removed wrought iron fencing.

Optional additions include an alternative roof covering for a 40'x22' area, installation of Infratech Electric Patio Heater for 800 SF coverage, overhead string lighting for a 32'x19' space, replacement of existing concrete pad (19'x32', approximately 600 SF), support columns as an alternative to wall extension, and a reduced 22'x22' lean-to roof option using the existing wall. This file appears to be related to a Request for Information (RFI) from the Department of the Army National Guard seeking market research for potential future acquisition of these improvements.

View the file

Other files

File Type Posted
20241217_142810.jpg JPG image
20241217_142627.jpg JPG image
20241217_142849.jpg JPG image
20241217_142859.jpg JPG image
20241217_142617.jpg JPG image
B5008 - Patio Improvements_Rev 1.pptx PPTX presentation

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Base Bid: Lean-to Roof Installation Contractor to provide “lean to” style overhead roof connected to building and distributed and connected to brick wall. Approximate dimensions of roof would be 40 ft in length and 22 ft in width. Water runoff shall be routed through gutter and downspout into adjacent parking lot.

Base Bid: Brick Wall Construction Contractor shall remove existing 18-foot section of wrought iron fencing and replace with a CMU wall with brick exterior to match and preferably tie into, adjacent wall to North. This wall will need to be able to support and connect the proposed “lean to” roof structure.

Base Bid: Electrical Outlet Installation Contractor to supply two additional electrical outlets (120V - exterior rated) with surface mounted conduit. All exposed exterior conduit shall be painted “espresso brown” color.

Option: Roof Alternative Contractor shall install shade/rain cover over area shaded in BROWN (40’x22’).

Option: Patio Heating Contractor shall install Infratech Electric Patio Heater (or approved equal) on underside of roof for 800SF of coverage, if electrical supply is sufficient Base Bid: Fill in Holes: Contractor to remove existing electrical lines and approximately 70 feet of wrought iron fencing from concrete pad and fill holes as appropriate.

Option: Patio Lighting Contractor shall install overhead “string-type” lighting across entire 32’ x 19’ space.

Option: Pad Replacement Contractor shall remove the existing concrete in area shaded in BLUE and replace with new concrete for a finished smooth surface (approx. 19’ x 32’) = 600 SF Option: Columns In lieu of extending the wall, contractor shall provide and install support columns for the lean-to roof Option: 22’x22’ Lean-to Roof Using existing wall only image1.png