B5008 - Patio Improvements_Rev 1.pptx

PPTX presentation 2 MB Posted

Attached to
Bldg 5008 Patio Additions
Solicitation number
W50S7S25Q0003
Issued by

About this file

This PowerPoint file outlines the base bid requirements and optional elements for patio improvements to Building 5008. The base bid work includes installing a 40'x22' lean-to style roof connected to the building and brick wall, constructing an 18-foot CMU wall with brick exterior to replace existing wrought iron fencing, installing two 120V exterior electrical outlets with painted conduit, and filling approximately 70 feet of holes from removed wrought iron fencing and electrical lines.

Optional components include an alternative roof/shade cover for the 40'x22' area, installation of Infratech Electric Patio Heater for 800 SF coverage, overhead string lighting across a 32'x19' space, and replacement of existing concrete pad (approximately 19'x32' or 600 SF) in the designated blue-shaded area. This is part of a pre-solicitation effort by the Department of the Army National Guard, with responses to be submitted to 126.ARW.MSC@us.af.mil for market research purposes.

View the file

Other files

File Type Posted
B5008 - Patio Improvements_Rev 2.pptx PPTX presentation
20241217_142810.jpg JPG image
20241217_142627.jpg JPG image
20241217_142849.jpg JPG image
20241217_142859.jpg JPG image
20241217_142617.jpg JPG image

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Base Bid: Lean To Roof Installation Contractor to provide “lean to” style overhead roof connected to building and distributed and connected to brick wall. Approximate dimensions of roof would be 40 ft in length and 22 ft in width. Water runoff shall be routed through gutter and downspout into adjacent parking lot.

Base Bid: Brick Wall Construction Contractor shall remove existing 18-foot section of wrought iron fencing and replace with a CMU wall with brick exterior to match and preferably tie into, adjacent wall to North. This wall will need to be able to support and connect the proposed “lean to” roof structure.

Base Bid: Electrical Outlet Installation Contractor to supply two additional electrical outlets (120V - exterior rated) with surface mounted conduit. All exposed exterior conduit shall be painted “espresso brown” color.

Option: Roof Alternative Contractor shall install shade/rain cover over area shaded in BROWN (40’x22’).

Option: Patio Heating Contractor shall install Infratech Electric Patio Heater (or approved equal) on underside of roof for 800SF of coverage, if electrical supply is sufficient Base Bid: Fill in Holes: Contractor to remove existing electrical lines and approximately 70 feet of wrought iron fencing from concrete pad and fill holes as appropriate.

Option: Patio Lighting Contractor shall install overhead “string-type” lighting across entire 32’ x 19’ space.

Option: Pad Replacement Contractor shall remove the existing concrete in area shaded in BLUE and replace with new concrete for a finished smooth surface (approx. 19’ x 32’) = 600 SF image1.png image2.png image3.png image4.png