Mob Equipment Salient_Characteristics.pdf
PDF 242 KB Posted
- Attached to
- Mob Equipment
- Solicitation number
- W50S6U26QA021
- Issued by
-
Department of the Army National Guard
About this file
This document is a Brand Name MOB Equipment Salient Characteristics specification for the 261st Cyber Operations Squadron (261 COS), detailing required equipment for delivery to 15900 Victory Blvd, Sepulveda Air National Guard Station, Van Nuys, CA 91406, with a target delivery/installation date of 90 days after receipt of order (ARO).
The procurement specifies five line items totaling required equipment: (1) 10 units of 480GB M.2 NVMe SSDs (Dell P/N 345-BGQV or 400-BPWT or OEM-certified equivalent) for Dell PowerEdge R6615 server boot storage, which must be new, TAA-compliant, compatible with Dell PowerEdge BOSS S2 controller cards, and maintain OEM warranty and support to preserve the CVAH system's Authority to Operate (ATO); (2) 12 units of Micron 30.72TB NVMe SSDs (Model MTFDKCC30T7TGR1BK1DFCYYR) for high-density data center storage, requiring PMO certification and sustained write speeds of at least 3,000 MB/s to prevent critical data packet loss from forensic and packet capture tools; (3) 1 Cisco W-ANTM2050D-RPSMA dual-band omnidirectional dipole antenna supporting 2.4 GHz and 5.8 GHz frequencies with RP-SMA male connector; (4) 1 AG Antenna Group AGA195-10-RSM-RSF RF antenna extension cable (118.1 inches/3 meters) with RP-SMA connectors; and (5) 2 units of Cisco LTE-ANTM-SMA-D 890-960 MHz antennas with 1-meter length, RP-SMA connectors, and 50-ohm impedance. All components must be new and certified for compatibility with the CVAH weapon system and its operational requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Brand Name MOB Equipment Salient Characteristics 261st Cyber Operations Squadron (261 COS)
Delivery Address: 15900 Victory Blvd, Sepulveda Air National Guard Station Van Nuys, CA 91406.
Target Date of Delivery/Installation – 90 days ARO
ITEM SUPPLIES/SERVICES QTY UNIT PRICE TOTAL
0001 SSD, Hot-Swappable 10
Item description 480GB M.2 NVMe SSD for the server's BOSS-N1 Controller
Brand Dell
Model Dell P/N 345-BGQV or 400-BPWT or OEM-certified equivalent. Dell PowerEdge R6615
Mission Function Enterprise Server Boot Storage
Salient characteristics New and TAA compliant.
Capacity: 480GB Interface: NVMe PCIe Form Factor: M.2 Workload Profile: Read Intensive Compatibility: Must be compatible with Dell PowerEdge BOSS S2 controller cards.
Additional Information Must be new and certified by the Original Equipment Manufacturer (OEM) for 100% compatibility with the BOSS (Boot Optimized Storage Solution) S2 controller card. These drives are associated with Dell 6615 server. Tag number for reference (Tag number:
DJ7QW54).
Must maintain the server's existing OEM warranty and support agreement.
Maintaining the CVAH system's Authority to Operate (ATO) is dependent on using only OEM-certified components that ensure the validity of the warranty and support structure.
ITEM SUPPLIES/SERVICES QTY UNIT PRICE TOTAL
0002 SSD, NVMe 12
Item description 30.7 TB 2.5 NVME SSD
Brand Micron
Model MTFDKCC30T7TGR1BK1DFCYYR
Mission Function High-Density Data Center Storage
Salient characteristics New and TAA compliant.
Capacity: 30.72TB Interface: PCIe Gen4 x4, NVMe
Form Factor: U.3 (15mm thickness) Endurance: Minimum 0.3 Drive Writes Per Day
(DWPD)
Security: 256-bit AES Encryption capability.
Additional Information Performance: Must be new and demonstrate sustained write speeds of at least 3,000 MB/s under a continuous, high-volume data load without thermal throttling or performance degradation.
Compatibility Note: These drives are associated with Dell PowerEdge server with Service Tag for reference: DJ7QW54. The Dell Part Number for this drive is 0DPR0G.
Must be officially certified by the CVAH Program Management Office (PMO) for use in the weapon system. The CVAH mission requires capturing massive, concurrent data streams from forensic and packet capture tools. PMO testing confirmed that only this level of performance prevents critical data packet loss. The system's Authority to Operate (ATO) and operational stability depend on using only PMO-certified components.
ITEM SUPPLIES/SERVICES QTY UNIT PRICE TOTAL
0003 Antenna, Dual Band 1
Item description W-ANTM2050D-RPSMA omnidirectional dipole antenna
Brand CISCO
Model W-ANTM2050D-RPSMA
Salient Characteristics New dual band omnidirectional antenna. It is used to provide wireless signal transmission and reception.
Additional information Frequency: Dual-band support (2.4 GHz and 5.8 GHz)
Pattern: Omni-directional• Physical: Terminal/dipole design with an articulating hinge• Connector Type:
RP-SMA (Male).
ITEM SUPPLIES/SERVICES QTY UNIT PRICE TOTAL
0004 RF Antenna Ext. 1
Item description AG Antenna Group AGA195-10-RSM-RSF. Cable length: 118.1" (3 m), Connector 1: RP-SMA, Connector 2: RP-SMA
Brand AG Antenna Group
Model AGA195-10-RSM-RSF
Salient Characteristics
New used to connect wireless devices to their antennas.
It bridges the gap between electronics to improve signal strength and positioning.
Additional information
ITEM SUPPLIES/SERVICES QTY UNIT PRICE TOTAL
0005 890-960MHZ
ANTENNA 2
Item description 698 MHz to 960 MHz ANTENNA
Brand CISCO
Model LTE-ANTM-SMA-D
Salient Characteristics Must operate within the 890-960 MHz frequency range. Designed to improve signal reception and transmission.
Length: 1 Meter (approx. 3.3 feet) • Connectors: RP- SMA Male to RP-SMA Female• Impedance: 50 Ohm
• Application: Shielded coaxial rated for standard Wi- Fi frequencies.