200129 Eielson EMCS Type B Final_STAMPED.pdf

PDF 19 MB Posted

Attached to
EMCS/DDC Recommissioning Federal contract opportunity
Solicitation number
W50S6K23Q0003
Issued by
Department of the Army National Guard

About this file

This file relates to a federal solicitation for EMCS/DDC recommissioning services. The Army National Guard is seeking proposals under solicitation number W50S6K23Q0003 to provide energy management control system and direct digital control system recommissioning at Eielson Air Force Base in Alaska. Offerors must have experience servicing similar control systems and be able to perform testing, calibration, programming, and staff training. Proposals are due by February 8, 2023 and the period of performance is expected to last approximately six months following award. The solicitation is designated as 100% small business set aside.

View the file

Other files for this federal contract opportunity

Other files attached to EMCS/DDC Recommissioning, newest first.
File Type Posted
DDC Recommissioning Q and A.pdf PDF
3. FTQW23-2101 Submittal Register.xlsx XLSX spreadsheet
1. 168 WG Map.pdf PDF
PWS FTQW23-2101 Recommission EMCS-DDC Systems v2.pdf PDF
2. CY23 168 WG Quick-Look Calendar_AWS & RSD.pdf PDF
Combo EMCS-DDC Recommissioning (6July2023).pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ALASKA ANG REPAIR EMCS & METERS

EIELSON AIR FORCE BASE, ALASKA

01/29/2020

PROJECT NO. FTQW 16-2602

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C

S

M e t e r s

G-001

4259500-161602.01

COVER SHEET

JANUARY 29, 2020

SNW

RJH

AMT

X

T

E C

H C

A D

G

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

01/29/20 TYPE B FINAL

Sheet List Table

Sheet Number Sheet Title

G-001 COVER SHEET

M-001

SYMBOLS, ABBREVIATIONS, DETAILS AND SCHEDULES

M-002 OVERALL SITE PLAN

M-003 ENLARGED SITE UTILITY PLANS

M-101 BUILDING 1168 FLOOR PLANS

M-102 BUILDING 1171 FIRST FLOOR PLAN

M-103 BUILDING 1171 CATWALK LEVEL PLAN

M-104 BUILDING 1172 FIRST FLOOR PLAN

M-105 BUILDING 1173 FIRST FLOOR PLAN

M-106 BUILDING 1176 FIRST FLOOR PLAN

M-107 BUILDING 1176 SECOND FLOOR PLAN

M-108 BUILDING 3127 FIRST AND SECOND FLOOR PLANS

M-109 BUILDING 3127 THIRD FLOOR PLAN

M-110 BUILDING 3128 FIRST FLOOR PLAN

M-111 BUILDING 3129 FIRST FLOOR PLAN

M-112 BUILDING 3130 FIRST FLOOR PLAN

M-113 BUILDING 3131 FIRST FLOOR PLAN

M-114 BUILDING 3132 FIRST FLOOR PLAN

M-115 BUILDING 3133 FIRST FLOOR PLAN

M-116 BUILDING 3133 SECOND FLOOR PLAN

M-117 BUILDING 3180 FIRST FLOOR PLAN

M-118 BUILDING 3225 FIRST FLOOR PLAN

M-119 BUILDING 3225 SECOND FLOOR PLAN

M-120 BUILDING 32251 FIRST FLOOR PLAN

M-121 BUILDING 3345 FIRST FLOOR PLAN

M-601 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1168

M-602 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1168

M-603 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1171

M-604 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1171

M-605 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1171

M-606 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1172

M-607 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1173

M-608 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1176

M-609 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1176

M-610 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1176

M-611 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1176

M-612 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1176

M-613 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3127

M-614 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3127

M-615 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3127

M-616 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3129

M-617 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3129

M-618 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3129

M-619 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3129

M-620 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3130

M-621 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3130

M-622 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3130

M-623 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3130

M-624 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3180

M-625 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3133

M-626 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3133

M-627 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3133

M-628 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3225

M-629 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3225

M-630 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3225

M-631 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3345

M-701 SYSTEM ARCHITECTURE

M-801

SYSTEM ARCHITECTURE ENLARGED - BLDGS 1168,1171,1172 & 1173

M-802

SYSTEM ARCHITECTURE ENLARGED - BLDGS 1176, 3127 & 3128

M-803 SYSTEM ARCHITECTURE ENLARGED - BLDGS 3129 AND 3130

M-804

SYSTEM ARCHITECTURE ENLARGED - BLDGS 3133, 3180, 3225, 3345

Robyn Henke

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-001

SYMBOLS,

ABBREVIATIONS,

DETAILS AND

SCHEDULES

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

ELECTRIC METER (EM) SCHEDULE

MARK

MANUFACTURER, MODEL NUMBER

VOLTAGE

FREQUENCY

ACCURACY

COMM PORT (2)

COMM PROTOCOL LOCATION REMARKS

EM-1168 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

EM-1168 HBO ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

EM-1171 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

EM-1172 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

EM-1173 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

EM-1176 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

EM-1176 HBO ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

EM-3127 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

EM-3129 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

EM-3130 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

EM-3133 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

EM-3180 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

EM-3225 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

EM-32251 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

EM-3345 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz

0.5% (1)

ETHERNET MODBUS TCP/IP SEE PLANS

REMARKS:

(1) APPARENT POWER

(2) UNIT SHALL BE PROVIDED WITH MINIMUM (2) INTERNAL COMM PORTS FOR PULSE OUTPUT.

WATER METER (WM) SCHEDULE

MARK

MANUFACTURER, MODEL NUMBER

SIZE

(IN)

FLUID TYPE

DESIGN

PRESS.

(PSI)

FLUID

TEMP.

(°F)

DESIGN FLUID FLOW RATE

FLUID

SPECIFIC

GRAVITY LOCATION REMARKSMAX. MIN. UNITS

WM-1168

BADGER, TURBO 200

2 WATER 60 50 310 4 GPM 1 BLDG 1168

(3)

WM-1172

BADGER, MODEL 35

3/4 WATER 60 50 35 0.75 GPM 1 BLDG 1172

(2)

WM-1176

BADGER, TURBO 200

2 WATER 60 50 310 4 GPM 1 BLDG 1176

(1)

WM-3127

BADGER, TURBO 200

3 WATER 60 50 450 4 GPM 1 BLDG 3127

(1)

WM-3129

BADGER, TURBO 200

3 WATER 60 50 450 4 GPM 1 BLDG 3129

(1)

WM-3130

BADGER, TURBO 200

2 WATER 60 50 310 4 GPM 1 BLDG 3130

(1)

WM-3133

BADGER, TURBO 200

2 WATER 60 50 310 4 GPM 1 BLDG 3133

(1)

WM-3345

BADGER, TURBO 200

2 WATER 60 50 310 4 GPM 1 BLDG 3345

(1)

REMARKS:

(1) PROVIDE METER WITH ER420-LP TOTALIZER AND RATE OF FLOW INDICATOR FOR CONNECTION TO DDC SYSTEM.

(2) PROVIDE METER WITH HR-E 4-20 ENCODER AND RATE OF FLOW INDICATOR FOR CONNECTION TO DDC SYSTEM.

(3) PROVIDE METER WITH ER420-LP TOTALIZER AND REMOTE RATE OF FLOW INDICATOR FOR CONNECTION TO DDC SYSTEM. COORDINATE REMOTE

RATE OF FLOW INDICATOR LOCATION WITH OWNER.

CONDENSATE METER (CDM) SCHEDULE

MARK

MANUFACTURER, MODEL NUMBER

SIZE

(IN)

FLUID TYPE

DESIGN

PRESS.

(PSI)

FLUID

TEMP.

(°F)

DESIGN FLUID FLOW RATE

FLUID

SPECIFIC

GRAVITY LOCATION REMARKSMAX. MIN. UNITS

CDM-1176

BADGER, INDUSTRIAL TURBO

2 WATER 60 210 200 8 GPM 1 BLDG 1176

(1)

REMARKS:

(1) PROVIDE METER WITH MS-ER1 TOTALIZER PULSE TRANSMITTER AND SIX-DIGIT TOTALIZING REGISTER FOR CONNECTION TO DDC SYSTEM.

BACKFLOW PREVENTION DEVICE SCHEDULE

DESIGN CONDITIONS

ISOLATION VALVES MAXIMUM

SIZE FLOW PD BODY TEMP MAWP LENGTH

MARK

MFR, MODEL NUMBER

TYPE

(IN) (GPM) (PSID)

MTL TYPE MTL PORTS

(F) (PSIG) (IN) (2)

REMARKS

BPD-3130

WATTS, LF909M1

1013 2 75 10

BRZ (11)

BL

BRZ (11)

NPT 80.0 150.0 20.0

(31)(32)

TYPE ABBREVIATIONS

1012 DOUBLE CHECK VALVE ASSEMBLY WITH INTERMEDIATE ATMOSPHERIC BREAK IAW ASSE-1012

BL BALL

1013 REDUCED PRESSURE ZONE ASSEMBLY IAW ASSE-1013

GT-OSY

GATE, RESILIENT SEAT, OUTSIDE STEM AND YOKE

1015 DOUBLE CHECK VALVE ASSEMBLY IAW ASSE-1015

REMARKS:

(11) LEAD FREE

(31) PROVIDE INDIRECT DRAIN FROM VALVE TO DRAIN LOCATION. CONNECT DRAIN TO VALVE WITH AIR GAP

(32) SS RELIEF VALVE SEATS

NC

M

MAIN BYPASS

3/4" - 1-1/2" 3/4"

2" - 3" 1"

2"

3"

4"

4"

6"

8"

WATER SERVICE

MAIN

BYPASS. PIPE

SIZE PER TABLE

WATER METER PIPING (INFORMATIONAL ONLY)

NO SCALE

CONDUITS TO

TERMINAL

TOP VIEW

B

A

PROVIDE BUSHING ON ALL CONDUIT ENDS

PROVIDE MOUSE HOLE AS BOTTOMIN BASE (IN BOTTOM

SECTION IF STACKED)

CONDUIT DEPTH SHOWN IS APPROXIMATE. FIELD VERIFY TO

PROVIDE SLOPE IN CONDUIT AWAY FROM BUILDING.

POSITION HANDHOLE AND CONDUITS TO MAXIMIZE

DIMENSIONS "A" AND "B".

SEAL DUCTS/CONDUIT WITH 3M SCOTCHCAST 4416 TO

PREVENT ENTRY OF WATER INTO THE DUCTS. SEAL

OCCUPIED DUCTS FOLLOWING CABLE INSTALLATION.

DETAIL NOTES:

1.

2.

3.

4.

5.

INCOMING CONDUIT

NEW INGROUND

PULLBOX (HANDHOLE)

CROSS-SECTION A

HANDHOLE LID

PVC CONDUIT(S)

TO TERMINAL

POSITION CONCRETE

PAVER UNDER EACH

CORNER (4) OF HANDHOLE

TO PREVENT SETTLING.

SLOPE CONDUIT AWAY

FROM BUILDING.

BACKFILL TO WITHIN

2-INCHES OF

FINISHED GRADE

DIM "A"

BUILDING

INTERIOR

MOGUL-TYPE

LB FITTING

CONDUIT

12" BED OF COMPACTED

CRUSHED ROCK. EXTEND

ROCK 12" BEYOND PERIMETER

OF HANDHOLE ON ALL SIDES.

CROSS-SECTION B

CONDUITS FROM

PULLBOX TO BUILDING

INTERIOR

DIM "B"

BUILDING

EXTERIOR WALL

IMC CONDUIT TO

COMMUNICATIONS

ROOM OR OTHER

SPACE

UNDERGROUND BOX (HANDHOLD) DETAIL - TERMINAL ENTRANCE - PLN

NO SCALE

ELECTRIC METER

CT CONNECTIONS

VOLTAGE CONNECTIONS

F1

F2

F3

CT WIRING

VOLTAGE WIRING

(6-INPUTS)

(MAXIMUM)

RS485 TWISTED PAIR

CAT6 COPPER

EMCS

CONTROLLER

NEW

COMM RACK

EXISTING BUILDING MAIN POWER

NOTES:

1.

2.

THIS DIAGRAM IS FOR REFERENCE ONLY TO

ILLUSTRATE THE SYSTEM COMPONENTS OF THE

METERING SYSTEM.

SEE ALL DRAWING DETAILS AND SCHEMATICS

FOR PARTS, WIRING, AND INSTALLATION

DETAILS.

OVERALL METERING SYSTEM COMPONENT BLOCK DIAGRAM DETAIL

NO SCALE

OR ETHERNET

GROUND CUT AWAY

GENERAL NOTES:

1. THIS DETAIL REPRESENTS THE ENTIRE TRENCH AROUND BUILDING AND

ENCOMPASS MULTIPLE OBSTACLES FOUND IN TRENCH PATH. THIS

DETAIL IS FOR GENERAL REFERENCE AND DOES NOT REFER TO ONE

PARTICULAR LOCATION ON SITE

THIS SECTION REPRESENTS

PORTIONS OF TRENCH PASSING

THROUGH GRASSY/UN PAVED EARTH

BACKFILL AND COMPACT EARTH

AFTER CONDUIT IS INSTALLED

UNDISTURBED EARTH

UNDISTURBED PAVED SURFACE

30"

BACKFILL AND COMPACT EARTH TOPPED WITH COMPACTED

AGGREGATE BEFORE RESTORING ASPHALT SURFACE.

COORDINATE WITH FIELD CONDITIONS TO MATCH THICKNESS

OF ASPHALT AND DEPTH OF COMPACTED AGGREGATE BASE

36"

30"

CORE 8" INTO CONCRETE EVERY 12" ON CENTER. PLACE #5

REBAR BEDDED IN EPOXY PRIOR TO RESTORING CONCRETE

18"

DEPTH OF TRENCH

LAP REBAR 2" IN CENTER OF TRENCH

DIRECT BURIED CONDUIT

UNDISTURBED EARTH

BACKFILL AND COMPACT EARTH

AFTER CONDUIT IS INSTALLED

THIS SECTION REPRESENTS

PORTIONS OF TRENCH PASSING

THROUGH ASPHALT SURFACES

THIS SECTION REPRESENTS

PORTIONS OF TRENCH PASSING

THROUGH CONCRETE PAVING

MATCH THICKNESS OF CONCRETE PAVING IN FIELD

COMPACTED AGGREGATE DEPTH TO

MATCH THICKNESS OF

SURROUNDING PAVEMENT SECTION

18"

18"

IN ALL LOCATIONS

GROUND TRENCH DETAIL

NO SCALE

01/29/20 TYPE B FINAL

21.0°

28.5°

M-003

M-003

PARKING LOT HBO ELECTRIC METER

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-002

OVERALL SITE PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

ROAD

EXISTING PAVEMENT

SITE PLAN KEYED NOTES:

7.124 NEW UNDERGROUND CONDUIT MAY BE TRENCHED AND DIRECT BURIED OR

DIRECTIONALLY BORED. UNDERGROUND CONDUIT LOCATIONS SHALL BE

FIELD VERIFIED AND ADJUSTED AS NECESSARY TO AVOID OBSTRUCTIONS. SEE

DETAILS ON SHEET M-001.

7.125 SEE CONTINUATION ON SHEET M-108.

7.126 SEE CONTINUATION ON SHEET M-110.

7.127 SEE CONTINUATION ON SHEET M-113.

7.128 SEE CONTINUATION ON SHEET M-114.

7.129 SEE CONTINUATION ON SHEET M-112.

2" CONDUIT

(UNDERGROUND)

2" CONDUIT

(UNDERGROUND)

2" CONDUIT

(UNDERGROUND)

NEW HANDHOLE

APPROXIMATE LOCATION OF

EXISTING UNDERGROUND

ELECTRICAL FEED TO BLDG 3132

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-003

ENLARGED SITE

UTILITY PLANS

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

T

R

U

E

M

A

G

21.0°

28.5°

SITE UTILITY PLAN - ABI#1

1/8" = 1'-0"

SITE UTILITY PLAN - ABI#2

1/8" = 1'-0"

ELECTRIC METER (E)

FOR HBO'S

CONTROL PANELS (E)

COND. METER (E)

WATER METER

MAIN ELECTRIC METER

WM-1168

COMM RACK (E)

INSTALLED BENEATH

STAIR

EXISTING GCM

SUPERVISORY

CONTROLS

PANEL

MONACO FIRE PANEL (E)

PAINT BOOTH AHU-3 (E)

SHOP AHU-2 (E) (LOW)

ADMIN AHU-1 (E) (HIGH)

CONTROLS (E)

FLOOR PLAN KEYED NOTES:

7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE

LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET

PORT.

7.102 DEMOLISH EXISTING WATER METER. PROVIDE NEW METER IN SAME LOCATION

AS EXISTING. MODIFY PIPING AS NECESSARY TO ACCOMMODATE NEW METER.

SEE 3/M-101.

7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER

SHALL INTERFACE WITH DDC SYSTEM.

7.104 STEAM CONDENSATE, WATER AND ELECTRIC METER OUTPUTS SHALL BE

WIRED TO EXISTING MICROZONE CONTROLLERS MZ01, MZ02 AND MZ10. SEE

POINTS CHARTS ON SHEET M-601. PROVIDE WIRE AND CONDUIT REQUIRED TO

CONNECT ALL METERS TO EXISTING CONTROLLER(S).

7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED

AND WALL MOUNTED IN THE LOCATION SHOWN.

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-101

BUILDING 1168 FLOOR

PLANS

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 1168 FIRST FLOOR PLAN

1/8" = 1'-0"

BUILDING 1168 SECOND FLOOR PLAN

1/8" = 1'-0"

M

A

G

N T

R

U

E

N

28.5°

21.0°

BUILDING 1168 WATER METER EXISTING/DEMO

NO SCALE

COMM AND EXISTING

GCM SUPERVISORY

CONTROL PANELS

ELECTRIC METER

COND AND WATER METERS (E)

FIRE ALARM PANELS

AND EQUIPMENT

AIR COMPRESSOR (E)

ELEC (E)

CONTROLS (E)

GAS DETECTION CONTROLS (E)

FLOOR PLAN KEYED NOTES:

7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE

LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET PORT.

7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER

SHALL INTERFACE WITH DDC SYSTEM.

7.104 PROVIDE WIRE AND CONDUIT REQUIRED TO CONNECT ALL METERS TO EXISTING

CONTROLLER(S). STEAM CONDENSATE, WATER AND ELECTRIC METER OUTPUTS

SHALL BE WIRED TO EXISTING MICROZONE CONTROLLERS MZ17. SEE POINTS

CHARTS ON SHEET M-605.

7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED

AND WALL MOUNTED IN THE LOCATION SHOWN.

M-102

COMM RACK (E)

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-102

BUILDING 1171 FIRST

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

M

A

G

N T

R

U

E

N

28.5°

21.0°

BUILDING 1171 FIRST FLOOR PLAN

3/32" = 1'-0"

LARGE SCALE UTILITY RM 102.1

NO SCALE

EXISTING AHU CONTROLS

IN THIS AREA

(5) AHUs ON MEZZANINE

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-103

BUILDING 1171

CATWALK LEVEL PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

M

A

G

N T

R

U

E

N

28.5°

21.0°

BUILDING 1171 CATWALK LEVEL PLAN

3/32" = 1'-0"

FIRE ALARM (E)

CONTROLS (E)

COND METER (E)

AHU (E) ON MEZZANINE

MAIN ELECTRIC METER

WM-1172

FLOOR PLAN KEYED NOTES:

7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER

SHALL INTERFACE WITH DDC SYSTEM.

7.104 PROVIDE WIRE AND CONDUIT REQUIRED TO CONNECT ALL METERS TO EXISTING

CONTROLLER(S). STEAM CONDENSATE, WATER AND ELECTRIC METER OUTPUTS

SHALL BE WIRED TO EXISTING MICROZONE CONTROLLER MZ19. SEE POINTS

CHART ON SHEET M-606.

7.105 PROVIDE NEW WATER METER IN EXISTING WATER MAIN. MODIFY PIPING AS

NECESSARY TO ACCOMMODATE NEW METER.

7.118 EXISTING MICROZONE CONTROLS ARE ASSOCIATED WITH GCM SUPERVISORY

CONTROLLER IN BLDG 1171. MAINTAIN ASSOCIATION BETWEEN THESE

CONTROLS AND THE NEW SUPERVISORY CONTROLLER IN BLDG 1171.

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-104

BUILDING 1172 FIRST

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

T

R

U

E

M

A

G

21.0°

28.5°

BUILDING 1172 FIRST FLOOR PLAN

1/4" = 1'-0"

FIRE ALARM

ELEC PANEL (E)

ELEC METER

CONTROLS

COND METER (E)

FLOOR PLAN KEYED NOTES:

7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER

SHALL INTERFACE WITH DDC SYSTEM.

7.104 PROVIDE WIRE AND CONDUIT REQUIRED TO CONNECT ALL METERS TO EXISTING

CONTROLLER(S). STEAM CONDENSATE IS WIRED TO MZ13 AND SHALL BE

INTEGRATED INTO NEW FRONT END. ELECTRIC METER OUTPUTS SHALL BE

WIRED TO EXISTING MICROZONE CONTROLLER MZ15. SEE POINTS CHART ON

SHEET M-607.

7.118 EXISTING MICROZONE CONTROLS ARE ASSOCIATED WITH GCM SUPERVISORY

CONTROLLER IN BLDG 1171. MAINTAIN ASSOCIATION BETWEEN THESE

CONTROLS AND THE NEW SUPERVISORY CONTROLLER IN BLDG 1171.

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-105

BUILDING 1173 FIRST

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

T

R

U

E

M

A

G

BUILDING 1173 FIRST FLOOR PLAN

1/4" = 1'-0"

ELEC METER (E)

COMM ROOM

COND METER (E)

WATER METER

EXISTING STEAM EQUIP

FOR THIS SIDE OF

BUILDING

EXISTING FIRE PANEL AND

PUMP CONTROLS

FIRE PUMP (E)

COMM (E) IN THIS AREA

OUTSIDE LIGHT

CONTACT (E)

SMALL AHU (E) FOR ELEC COOLING

CONTROL

PANEL (E)

CONTROL

PANEL (E)

EXISTING MAIN STEAM MECH FOR

THIS SIDE

NEW CONTROLLER

CDM-1176

FLOOR PLAN KEYED NOTES:

7.102 DEMOLISH EXISTING WATER METER. PROVIDE NEW METER IN SAME LOCATION

AS EXISTING. MODIFY PIPING AS NECESSARY TO ACCOMMODATE NEW METER.

7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER

SHALL INTERFACE WITH DDC SYSTEM.

7.104 PROVIDE NEW CONTROLLER FOR COLLECTION OF DATA FROM STEAM

CONDENSATE, WATER AND ELECTRICAL METERS. FIELD VERIFY LOCATION

FOR NEW CONTROLLER. PROVIDE WIRE AND CONDUIT REQUIRED TO

CONNECT ALL METERS TO NEW CONTROLLER. PROVIDE ELECTRICAL POWER

AND TRANSFORMERS NECESSARY FOR NEW CONTROLLER OPERATION.

7.106 PROVIDE NEW CONDENSATE METER IN EXISTING CONDENSATE MAIN. MODIFY

PIPING AS NECESSARY TO ACCOMMODATE NEW METER. SEE 2/M-106.

7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED

AND WALL MOUNTED IN THE LOCATION SHOWN.

CONDENSATE PUMP (E)

EXISTING 2" CONDENSATE

FROM EAST MECH RM

REMOTE ENCLOSURE

CONTAINING ELECTRICAL

METER FOR PARKING LOT

HBO'S (SEE SHEET M-002)

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-106

BUILDING 1176 FIRST

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 1176 FIRST FLOOR PLAN

1/16" = 1'-0"

T

R

U

E

M

A

G

CONDENSATE PIPE DEMOLITION

NO SCALE

CONTROL PANELS (E) FOR

AIRPLANE WASH SYSTEMS

HEAT TRACE CONTROL (E)

ADMIN AHU-9 (E)

EXISTING GCM SUPERVISORY

CONTROL PANEL

AHU-3 (E)

AHU-10 (E)

CONTROLS (E)

RADIANT FLOOR EQUIPMENT (E)

AHU-1 (E)

CONTROL PANELS (E)

AHU-11 (E)

AHU-12 (E)

AHU-4 (E)

RADIANT FLOOR EQUIPMENT (E)

AHU-2 (E)

AHU-15 (E)

AHU-8 (E)

CONTROLS (E)

SHOP AHU-7 (E)

BATTERY AHU-13 (E)

AHU-5 (E)

HEAT

TRACE

CONTROLS

(E)

EXISTING AHU

(ABANDONED)

AHU-6 (E)

CONTROLS (E)

FLOOR PLAN KEYED NOTES:

7.101 REMOVE EXISTING AND INSTALL NEW SUPERVISORY CONTROLLER IN THE

LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET

PORT.

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-107

BUILDING 1176

SECOND FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 1176 SECOND FLOOR PLAN

1/16" = 1'-0"

T

R

U

E

M

A

G

EXISTING ELEC

EXISTING COMM CLOSET

STEAM COND METER (E)

CONTROL

PANEL (E)

MONACO FIRE ALARM (E)

ELEC GEAR

GCM SUPERVISORY CONTROL PANEL

FLOOR PLAN KEYED NOTES:

7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE

LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET

PORT.

7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER

SHALL INTERFACE WITH DDC SYSTEM.

7.104 PROVIDE WIRE AND CONDUIT REQUIRED TO CONNECT ALL METERS TO

EXISTING CONTROLLER(S). STEAM CONDENSATE, WATER AND ELECTRIC

METER OUTPUTS SHALL BE WIRED TO EXISTING MICROZONE CONTROLLER

MZ02 OR MZ14. SEE POINTS CHART ON SHEET M-613 AND M-615.

7.105 PROVIDE NEW WATER METER IN EXISTING WATER MAIN. MODIFY PIPING AS

NECESSARY TO ACCOMMODATE NEW METER.

7.108 NEW CONTROL PANEL FOR TERMINATION OF COMMUNICATIONS CABLE FROM

BUILDING 3128. TERMINATE CABLE FOR FUTURE USE.

7.114 NEW UNDERGROUND TEMPERATURE CONTROLS CABLE. SEE SITE PLAN M-003

FOR CONTINUATION.

7.115 NEW IN-GROUND HAND-HOLE FOR ROUTING OF NEW TEMPERATURE

CONTROLS CABLE BETWEEN BUILDINGS.

7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED

AND WALL MOUNTED IN THE LOCATION SHOWN.

EXISTING WATER SERVICE

ENTRANCE

WM-3127 (IN VERTICAL)

ALL WORK WITHIN

CLOUDED REGION TO BE

PART OF ABI #1

ABI #1

AHU (E)AHU (E)

VFDs (E)

CONTROLS (E) (MZ-3, MZ-4 & MZ-9)

EXISTING COMM ROOM

VFDs (E)

AHU (E)AHU (E)

CONTROLS (E)

(MZ-10, MZ-11 &

MZ-12)

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-108

BUILDING 3127 FIRST

AND SECOND FLOOR

PLANS

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 3127 FIRST FLOOR PLAN

1/8" = 1'-0"

T

R

U

E

M

A

G

BUILDING 3127 SECOND FLOOR PLAN

1/8" = 1'-0"

VFDs (E)

AHU (E)

AHU (E)

CONTROLS (E) (MZ-7 & MZ-8)

EXISTING COMM ROOM

CONTROLS (E) (MZ-5 & MZ-6)

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-109

BUILDING 3127 THIRD

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 3127 THIRD FLOOR PLAN

1/8" = 1'-0"

T

R

U

E

M

A

G

CONTROL PANEL

FLOOR PLAN KEYED NOTES:

7.107 NEW MIN. 24"X24" CONTROL PANEL FOR TERMINATION OF COMMUNICATIONS

CABLE FROM BLDG 3127. TERMINATE CABLE FOR FUTURE USE.

7.114 NEW UNDERGROUND TEMPERATURE CONTROLS CABLE. SEE SITE PLAN M-003

FOR CONTINUATION.

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-110

BUILDING 3128 FIRST

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 3128 FIRST FLOOR PLAN - ABI #1

1/4" = 1'-0"

T

R

U

E

M

A

G

21.0°

28.5°

ALL WORK ON THIS SHEET IS FOR ABI #1

EXISTING COMM ROOM

FIRE PANEL (E)

EXISTING MEZZANINE

PANEL (E)

PANEL (E)

AHU-5 (E)

AHU-3 (E)

AHU-4 (E)

AHU-2 (E) W/VFD

EXISTING MEZZANINE

PANELS (E)

VFDs (E)

EXISTING COMM RACK

ELECTRICAL SERVICE

COND METER (E)

PANELS (E)

EXISTING MEZZANINE

EXISTING MEZZANINE

FIRE PANEL (E) (MAIN)

CONTROL PANEL

AHU-1 (E)

WATER METER

NEW CONTROLLER

FLOOR PLAN KEYED NOTES:

7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE

LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET PORT.

7.102 DEMOLISH EXISTING WATER METER. PROVIDE NEW METER IN SAME LOCATION

AS EXISTING. MODIFY PIPING AS NECESSARY TO ACCOMMODATE NEW METER.

SEE 2/M-111.

7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR, WITHIN

FIBERGLASS ENCLOSURE. NEW METER SHALL INTERFACE WITH DDC SYSTEM.

7.104 PROVIDE NEW CONTROLLER FOR COLLECTION OF DATA FROM STEAM

CONDENSATE, WATER AND ELECTRICAL METERS. FIELD VERIFY LOCATION

FOR NEW CONTROLLER. PROVIDE WIRE AND CONDUIT REQUIRED TO

CONNECT ALL METERS TO NEW CONTROLLER. PROVIDE ELECTRICAL POWER

AND TRANSFORMERS NECESSARY FOR NEW CONTROLLER OPERATION.

7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED

AND WALL MOUNTED IN THE LOCATION SHOWN.

7.119 BASE STAFF INDICATES THAT THE INLET ISOLATION VALVE FOR WATER METER

IS DAMAGED AND INOPERABLE. PROVIDE NEW ISOLATION VALVE. COORDINATE

WITH THE BASE TO ARRANGE SHUTOFF OF WATER TO THE FACILITY.

7.125 PROVIDE NEW 2" DIRECT BURIED UNDERGROUND CONDUIT AND TEMPERATURE

CONTROLS CABLE TO CONNECT NEW ELECTRICAL METER AND NEW

CONTROLLER. COORDINATE CONDUIT LOCATION WITH EXISTING ELECTRICAL

SERVICE.

WM-3129

GCM SUPERVISORY CONTROLLER

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-111

BUILDING 3129 FIRST

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 3129 FIRST FLOOR PLAN

3/32" = 1'-0"

T

R

U

E

M

A

G

21.0°

28.5°

3129 WATER METER EXISTING/DEMO

NO SCALE

MAU-1 (E)

CONNECTED TO

CO SENSORS

EXISTING MEZZANINE

AHU-3 (E)

GCM SUPERVISORY

CONTROL PANEL

EXISTING MEZZANINE

FIRE PANEL (E)

EXISTING AHU-2 (ABANDONED IN PLACE)

AHU-1 (E)

EXISTING MEZZANINE

CONTROL

PANELS (E)

COND METER (E)

EXISTING COMM ROOM

CONTROL

PANELS (E)

NEW CONTROLLER

WATER METER

WM-3130

CONTROL PANEL

FLOOR PLAN KEYED NOTES:

7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE

LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET PORT.

7.102 DEMOLISH EXISTING WATER METER. PROVIDE NEW METER IN SAME LOCATION

AS EXISTING. MODIFY PIPING AS NECESSARY TO ACCOMMODATE NEW METER.

7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER

SHALL INTERFACE WITH DDC SYSTEM.

7.104 PROVIDE NEW CONTROLLER FOR COLLECTION OF DATA FROM STEAM

CONDENSATE, WATER AND ELECTRICAL METERS. FIELD VERIFY LOCATION

FOR NEW CONTROLLER. PROVIDE WIRE AND CONDUIT REQUIRED TO

CONNECT ALL METERS TO NEW CONTROLLER.

7.108 NEW CONTROL PANEL FOR TERMINATION OF COMMUNICATIONS CABLE FROM

BUILDINGS 3131 AND 3132. TERMINATE CABLE FOR FUTURE USE.

7.114 NEW UNDERGROUND TEMPERATURE CONTROLS CABLE. SEE SITE PLAN M-003

FOR CONTINUATION.

7.115 NEW IN-GROUND HAND-HOLE FOR ROUTING OF NEW TEMPERATURE CONTROLS

CABLE BETWEEN BUILDINGS.

7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED

AND WALL MOUNTED IN THE LOCATION SHOWN.

7.118 PROVIDE NEW BACKFLOW PREVENTION DEVICE IN EXISTING COLD WATER

SERVICE. MODIFY PIPING AS NECESSARY TO ACCOMMODATE NEW BPD. REFER

TO 2/M-112.

EXISTING PORTS RACKS

BACKFLOW PREVENTER

BPD-3130

2" CW

WATER SERVICE (E)

ALL WORK WITHIN

CLOUDED REGION TO BE

PART OF ABI #2

ABI #2

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-112

BUILDING 3130 FIRST

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 3130 FIRST FLOOR PLAN

3/32" = 1'-0"

T

R

U

E

M

A

G

21.0°

28.5°

BUILDING 3130 WATER METER EXISTING CONDITIONS

NO SCALE

FIRE PANEL (E)

FLOOR PLAN KEYED NOTES:

7.109 NEW MIN. 24" x 24" CONTROL PANEL FOR TERMINATION OF COMMUNICATIONS

CABLE FROM BLDG 3130. TERMINATE CABLE FOR FUTURE USE.

7.114 NEW UNDERGROUND TEMPERATURE CONTROLS CABLE AND CONDUIT. SEE

SITE PLAN M-003 FOR CONTINUATION.

7.115 NEW UNDERGROUND CONDUIT FOR ROUTING OF NEW TEMPERATURE

CONTROLS CABLE BETWEEN BUILDINGS.

7.116 TEMPERATURE CONTROLS CABLE AND CONDUIT FROM NEW CONTROL PANEL

DOWN TO UNDERGROUND CONDUIT. CABLE RUNS FROM BLDG 3130.

NEW TEMPERATURE CONTROL

CABLE AND CONDUIT

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-113

BUILDING 3131 FIRST

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 3131 FIRST FLOOR PLAN - ABI #2

1/2" = 1'-0"

T

R

U

E

M

A

G

21.0°

28.5°

ALL WORK ON THIS SHEET IS FOR ABI #2

FLOOR PLAN KEYED NOTES:

7.109 NEW MIN. 24" x 24" CONTROL PANEL FOR TERMINATION OF COMMUNICATIONS

CABLE FROM BLDG 3130. TERMINATE CABLE FOR FUTURE USE.

7.114 NEW UNDERGROUND TEMPERATURE CONTROLS CABLE AND CONDUIT. SEE SITE

PLAN M-003 FOR CONTINUATION. CABLE RUNS FROM BLDG 3130.

7.116 TEMPERATURE CONTROLS CABLE AND CONDUIT FROM NEW CONTROL PANEL

DOWN TO UNDERGROUND CONDUIT.

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-114

BUILDING 3132 FIRST

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 3132 FIRST FLOOR PLAN - ABI #2

1/4" = 1'-0"

T

R

U

E

M

A

G

21.0°

28.5°

ALL WORK ON THIS SHEET IS FOR ABI #2

GCM SUPERVISORY

CONTROL PANELS

WATER METER

WM-3133

ELECTRIC METER

EXISTING

CONTROLS FOR

SHOP SYSTEMS

CONTROL CABINET (E) (LOW)

CONTROL CABINET (E) (HIGH)

AHU (E)

FLOOR PLAN KEYED NOTES:

7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE

LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET

PORT.

7.102 DEMOLISH EXISTING WATER METER. PROVIDE NEW METER IN SAME LOCATION

AS EXISTING. MODIFY PIPING AS NECESSARY TO ACCOMMODATE NEW METER.

SEE 2/M-115.

7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER

SHALL INTERFACE WITH DDC SYSTEM.

7.104 PROVIDE WIRE AND CONDUIT REQUIRED TO CONNECT ALL METERS TO

EXISTING CONTROLLER(S). WATER METER OUTPUT SHALL BE WIRED TO

EXISTING MICROZONE CONTROLLER MZ01. SEE POINTS CHART ON

SHEET M-625. ELECTRIC METER OUTPUT SHALL BE WIRED TO EXISTING

MICROZONE CONTROLLER MZ13. SEE POINTS CHART ON SHEET M-627.

7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED

AND WALL MOUNTED IN THE LOCATION SHOWN.

EXISTING COMM RACK

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-115

BUILDING 3133 FIRST

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 3133 FIRST FLOOR PLAN

1/8" = 1'-0"

T

R

U

E

M

A

G

3133 WATER METER EXISTING/DEMO

NO SCALE

AHU-2 (E)

AHU-1 (E)

CONTROL PANELS (E)

COND METER (E)

STEAM

PRVs (E)

LIGHTING

CONTROLS (E)

EXISTING FIRE PANEL &

MAIN MECH

FLOOR PLAN KEYED NOTES:

7.104 PROVIDE WIRE AND CONDUIT REQUIRED TO CONNECT ALL METERS TO EXISTING

CONTROLLER(S). STEAM CONDENSATE SHALL BE WIRED TO EXISTING

MICROZONE CONTROLLER MZ04. SEE POINTS CHART ON SHEET M-625.

PARKING LOT

HBO CONTROLS

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-116

BUILDING 3133

SECOND FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 3133 SECOND FLOOR PLAN

1/8" = 1'-0"

T

R

U

E

M

A

G

ELEC METER (E)

VFDs (E)

FIRE PANELS (E)

WATER METER (E)

STEAM CONDENSATE METER (E)

STRUCTURE WARE

CONTROL PANEL (E)

ERV (E)

LIEBERT ENERGY MANAGER

SERVES RM113 & RM116 (E)

LIEBERT

CONTROLS (E)

FLOOR PLAN KEYED NOTES:

7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE

LOCATION INDICATED.

7.110 INTEGRATE EXISTING SMART ELECTRIC METER INTO DDC SYSTEM.

7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED

AND WALL MOUNTED IN THE LOCATION SHOWN.

7.120 INTEGRATE EXISTING SMART WATER METER INTO NEW DDC SYSTEM.

7.121 INTEGRATE EXISTING SMART CONDENSATE METER INTO NEW DDC SYSTEM.

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-117

BUILDING 3180 FIRST

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 3180 FIRST FLOOR PLAN

1/8" = 1'-0"

T

R

U

E

M

A

G

21.0°

28.5°

AHU ON MEZZANINE (E)

AHU-3 ON MEZZANINE (E)

EXISTING GCM SUPERVISORY CONTROL PANELS

VFD (E)

WATER METER (E)

STEAM CONDENSATE METER (E)

FIRE ALARM PANEL (E)

ELEC METER (E)

EMCS OPERATOR WORKSTATION (E)

NEW CONTROLLER

FLOOR PLAN KEYED NOTES:

7.101 REMOVE EXISTING AND INSTALL NEW SUPERVISORY CONTROLLER IN THE

LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET

PORT.

7.103 INSTALL NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER

SHALL INTERFACE WITH DDC SYSTEM.

7.104 PROVIDE NEW CONTROLLER FOR COLLECTION OF DATA FROM ELECTRICAL

METER. FIELD VERIFY LOCATION FOR NEW CONTROLLER. PROVIDE WIRE AND

CONDUIT REQUIRED TO CONNECT METER TO NEW CONTROLLER.

7.111 PROVIDE WIRELESS COMMUNICATION POINT FOR DDC COMMUNICATION WITH

BLDG 32251. PROVIDE ETHERNET COMMUNICATIONS LINK WITH NEW DDC

SYSTEM. PROVIDE POINT-TO-POINT BRIDGE SIMILAR TO CAMBIUM NETWORKS

PTP-700.

7.122 COORDINATE LOCATION FOR INSTALLATION OF NEW OPERATOR

WORKSTATION AND CONTROLS SERVER.

7.123 EXISTING WATER METER IS WIRED TO COMMUNICATE WITH EXISTING DDC

SYSTEM. VERIFY COMMUNICATIONS INSTALLATION OF WATER METER.

ALL WORK WITHIN

CLOUDED REGION TO BE

PART OF ABI #3

ABI #3

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-118

BUILDING 3225 FIRST

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 3225 FIRST FLOOR PLAN

1/8" = 1'-0"

TRUE

M

A

G

AHU-2 (E)

NETWORK COMM RACK (E)

CONTROL PANELS (E)

FLOOR PLAN KEYED NOTES:

7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED

AND WALL MOUNTED IN THE LOCATION SHOWN.

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-119

BUILDING 3225

SECOND FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 3225 SECOND FLOOR PLAN

1/8" = 1'-0"

TRUE

M

A

G

ELEC & FIRE ALARM PANELS (E)

FLOOR PLAN KEYED NOTES:

7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER

SHALL INTERFACE WITH DDC SYSTEM.

7.112 PROVIDE WIRELESS COMMUNICATION POINT FOR DDC COMMUNICATION WITH

BLDG 3225. PROVIDE SIMILAR TO CAMBIUM NETWORKS PTP-700.

7.113 NEW MIN. 24"X24" CONTROL PANEL FOR TERMINATION OF CABLE FROM

WIRELESS SYSTEM. TERMINATE FOR FUTURE USE.

ALL WORK WITHIN

CLOUDED REGION TO BE

PART OF ABI #3

ABI #3

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-120

BUILDING 32251 FIRST

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 32251 FIRST FLOOR PLAN

1/4" = 1'-0"

T

R

U

E

M

A

G

21.0°

28.5°

FIRE ALARM (E)

NETWORK COMM RACK (E)

EXISTING GCM

SUPERVISORY

CONTROLS

AHU-1 (E)

ELEC METER

VFD (E)

STEAM

CONDENSATE

METER (E)

WATER METER

MAIN MECH

FLOOR PLAN KEYED NOTES:

7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE

LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET PORT.

7.102 DEMOLISH EXISTING WATER METER. PROVIDE NEW METER IN SAME LOCATION

AS EXISTING. MODIFY PIPING AS NECESSARY TO ACCOMMODATE NEW METER.

SEE 2/M-121.

7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER

SHALL INTERFACE WITH DDC SYSTEM.

7.104 PROVIDE WIRE AND CONDUIT REQUIRED TO CONNECT ALL METERS TO EXISTING

CONTROLLER(S). STEAM CONDENSATE IS WIRED TO MZ04 AND SHALL BE

INTEGRATED INTO NEW FRONT END. ELECTRIC METER AND WATER METER

OUTPUTS SHALL BE WIRED TO EXISTING MICROZONE CONTROLLER MZ04. SEE

POINTS CHART ON SHEET M-631.

7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED

AND WALL MOUNTED IN THE LOCATION SHOWN.

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-121

BUILDING 3345 FIRST

FLOOR PLAN

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

BUILDING 3345 FIRST FLOOR PLAN

3/16" = 1'-0"

T

R

U

E

M

A

G

21.0°

28.5°

3345 WATER METER EXISTING/DEMO

NO SCALE

T a n k e r

R d

A l a s k a

A

N G

R e p a i r

E

M C t e

M-601

MECHANICAL DIGITAL

CONTROL POINTS -

BUILDING 1168

JANUARY 29, 2020

SNW

RRW

AMT

X

T

E C

H C

A D

M

D

W G

P

M

E i e l s o n

A

F B

A

K

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

of

SHEET NO.

© Copyright

This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &

Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead and Hunt, Inc.

9600 NE Cascades Parkway, Suite 100

Portland, OR 97220 phone: 503-548-1494 meadhunt.com

DDC INPUT / OUTPUT SUMMARY TABLE - MZ-01 (EXISTING)

PROJECT NO: FTQW 16-2602

PROJECT:

HARDWARE SOFTWARE

EIELSON AFB Repair EMCS & Meters

LOCATION:

POINTS ALARMS

BUILDING 1168

DIGITAL ANALOG DIGITAL ANALOG EMCS FUNCTIONS

EXISTING POINT AVAILABILITY:

8 / 8 UI POINTS USED

2 / 4 AO POINTS USED

6 / 8 DO POINTS USED

O U

T P

U T

I N

P U

T

O U

T P

U T

I N

P U

T

E Q

U I P

M E

N T

A

T U

S

M A

I N

T E

N A

N C

E

P R

E S

S U

R E

H I G

H

L

I M

I T

L O

W

L

I M

I T

M A

I N

T E

N A

N C

E

D A

Y N

I G

H

E T

B A

C K

S C

H E

D U

L E

D

S

T A

R T

S

T O

P

T O

T A

L I Z

A T

I O

N

T R

E N

D

F I R

E

A

L A

R

I

T E

G R

A T

I O

N

D R

Y B

U L

B

E

C O

N O

M I Z

E R

F I R

E

A

L A

O

V E

R R

I D

E

Comments

POINT DESCRIPTION

OUTSIDE AIR TEMP. X X OAT

GLYCOL HOT WATER RETURN TEMP. X X X X GHWR TMP

GLYCOL HOT WATER SUPPLY TEMP. X X X X GHWS TMP

CIRCULATING PUMP 1 FLOW STATUS X X X CP-1 FLO ON/OFF

CIRCULATING PUMP 2 FLOW STATUS X X X CP-2 FLO ON/OFF

CIRCULATING PUMP 3 FLOW STATUS X X X CP-3 FLO ON/OFF

CIRCULATING PUMP 4 FLOW STATUS X X X CP-4 FLO ON/OFF

CIRCULATING PUMP 1 START/STOP X X CP-1 S/S ON/OFF

CIRCULATING PUMP 2 START/STOP X X CP-2 S/S ON/OFF

CIRCULATING PUMP 3 START/STOP X X CP-3 S/S ON/OFF

CIRCULATING PUMP 4 START/STOP X X CP-4 S/S ON/OFF

HX-1 CONTROL VALVE 1 POSITION X X HX-1 CV-1 %

HX-1 CONTROL VALVE 2 POSITION X X HX-1 CV-2 %

FAILSAFE X X FAILSAFE

FAILSAFE X X FAILSAFE

WATER METER X X X NEW POINT

DDC INPUT / OUTPUT SUMMARY TABLE - MZ-02 (EXISTING)

PROJECT NO: FTQW 16-2602

PROJECT:

HARDWARE SOFTWARE

EIELSON AFB Repair EMCS & Meters

LOCATION:

POINTS ALARMS

BUILDING 1168

DIGITAL ANALOG DIGITAL ANALOG EMCS FUNCTIONS

EXISTING POINT AVAILABILITY:

8 / 8 UI POINTS USED

2 / 4 AO POINTS USED

4 / 8 DO POINTS USED

O U

T P

U T

I N

P U

T

O U

T P

U T

I N

P U

T

E Q

U I P

M E

A

T U

S

M A

I N

T E

N A

N C

E

P R

E S

S U

R E

H I G

H

L

I M

I T

L O

W

L

I M

I T

M A

I N

T E

N A

N C

E

D A

Y N

I G

T

B A

C K

S C

H E

D U

L E

D

S

T A

R T

S

T O

P

T O

T A

L I Z

A T

I O

N

T R

E N

D

F I R

E

A

L A

T E

G R

A T

I O

N

D R

Y B

U L

B

E

C O

N O

M I Z

E R

F I R

E

A

L A

E

R R

I D

E

Comments

POINT DESCRIPTION

GLYCOL SYSTEM PRESSURE X X X X G-S PSI

CIRCULATING PUMP 5 STATUS X X X CP-5 FLO ON/OFF

CIRCULATING PUMP 5 STATUS X X X CP-6 FLO ON/OFF

SUPPLY FAN 2 DISCHARGE AIR TEMP. X X X X SF-2 DAT

ROOM 115 TEMP. X X X X R115 TMP

ROOM 114 TEMP. X X X X R114 TMP

DOMESTIC HOT WATER HEATER TEMP. X X X X DHWH TMP

SUPPLY FAN 2 DAMPER POSITION X X SF-2 DMPES %

DOMESTIC HOT WATER HEATER CONTROL VALVE POSITION X X DHWH CV %

CIRCULATING PUMP 5 START/STOP X X CP-5 S/S ON/OFF

ROOM 115 UNIT HEATER START/STOP X X UH-115 S/S ON/OFF

SUPPLY FAN 2 START/ STOP X X SF-2 S/S ON/OFF

ROOM 114 CONTROL VALVE X X R114 CV ON/OFF

ELECTRICAL METER X X X NEW POINT

DDC INPUT / OUTPUT SUMMARY TABLE - MZ-03 (EXISTING)

PROJECT NO: FTQW 16-2602

PROJECT:

HARDWARE SOFTWARE

EIELSON AFB Repair EMCS & Meters

LOCATION:

POINTS ALARMS

BUILDING 1168

DIGITAL ANALOG DIGITAL ANALOG EMCS FUNCTIONS

EXISTING POINT AVAILABILITY:

8 / 8 UI POINTS USED

4 / 4 AO POINTS USED

2 / 8 DO POINTS USED

O U

T P

U T

I N

P U

T

O U

T P

U T

I N

P U

T

E Q

U I P

M E

A

T U

S

M A

I N

T E

N A

N C

E

P R

E S

S U

R E

H I G

H

L

I M

I T

L O

W

L

I M

I T

M A

I N

T E

N A

N C

E

D A

Y N

I G

T

B A

C K

S C

H E

D U

L E

D

S

T A

R T

S

T O

P

T O

T A

L I Z

A T

I O

N

T R

E N

D

F I R

E

A

L A

T E

G R

A T

I O

N

D R

Y B

U L

B

E

C O

N O

M I Z

E R

F I R

E

A

L A

E

R R

I D

E

Comments

POINT DESCRIPTION

AH-1 DISCHARGE AIR TEMP. X X X X AH-1 DAT

AH-1 MIXED AIR TEMP. X X X X AH-1 MAT

AH-1 RETURN AIR TEMP. X X X X AH-1 RAT

AH-1 FLOW STATUS X X X AH1 FLO ON/OFF

AH-1 FREEZE STATUS X X X AH-1 FRZ

WINTER FILTER PRESSURE DROP X X X WINFILTER

AH-1 FILTER X X X FILTER

AH-1 OVERRIDE X X OVRRID ON/OFF

AH-1 PREHEAT CONTROL VALVE POSITION X X AH-1 PH CV %

AH-1 HEATING CONTROL VALVE POSITION X X AH-1 H CV %

AH-1 MIXED AIR DAMPER POSITION X X AH-1 MAD %

AH-1 EXHAUST AIR DAMPER POSITION X X AH-1 EAD %

AH-1 START/STOP X X AH-1 S/S ON/OFF

FIRE/SMOKE DAMPER X FS DMP ON/OFF

DDC INPUT / OUTPUT SUMMARY TABLE - MZ-04 (EXISTING)

PROJECT NO: FTQW 16-2602

PROJECT:

HARDWARE SOFTWARE

EIELSON AFB Repair EMCS & Meters

LOCATION:

POINTS ALARMS

BUILDING 1168

DIGITAL ANALOG DIGITAL ANALOG EMCS FUNCTIONS

EXISTING POINT AVAILABILITY:

8 / 8 UI POINTS USED

3 / 4 AO POINTS USED

4 / 8 DO POINTS USED

O U

T P

U T

I N

P U

T

O U

T P

U T

I N

P U

T

E Q

U I P

M E

A

T U

S

M A

I N

T E

N A

N C

E

P R

E S

S U

R E

H I G

H

L

I M

I T

L O

W

L

I M

I T

M A

I N

T E

N A

N C

E

D A

Y N

I G

T

B A

C K

S C

H E

D U

L E

D

S

T A

R T

S

T O

P

T O

T A

L I Z

A T

I O

N

T R

E N

D

F I R

E

A

L A

T E

G R

A T

I O

N

D R

Y B

U L

B

E

C O

N O

M I Z

E R

F I R

E

A

L A

E

R R

I D

E

Comments

POINT DESCRIPTION

AH-2 DISCHARGE AIR TEMP. X X X X AH-2 DAT

FILTER DIFFERENTIAL PRESSURE SWITCH X X X SUM FLTR ON/OFF

AH-2 DISCHARGE PRESSURE X X X AH-2 DPRS IN WC

AH-2 CURRENT SWITCH X X X AH-2 CT ON/OFF

AH-2 FREEZE STATUS X X AH-2 FRZ ON/OFF

AH-2 SMOKE DETECTOR X X X AH-2 SMK ON/OFF

FILTER PRESSURE DROP X X X FILTER IN WC

AH-2 OUTSIDE AIR DAMPER SWITCH X X AH-2 DMSW ON/OFF

HEATING COIL 3 VALVE POSITION X X HC-3 VLV %

HEATING COIL 4 VALVE POSITION X X HC-4 VLV %

AH-2 FAN SPEED X AH-2 SPEED %

AH-2 START/STOP X X AH-2 S/S ON/OFF

FIRE/SMOKE DAMPER X FS DMP ON/OFF

ROOM 117 DAMPER X R117 DMP ON/OFF

ROOM 119 DAMPER X R119 DMP ON/OFF

DDC INPUT / OUTPUT SUMMARY TABLE - MZ-05 (EXISTING)

PROJECT NO: FTQW 16-2602

PROJECT:

HARDWARE SOFTWARE

EIELSON AFB Repair EMCS & Meters

LOCATION:

POINTS ALARMS

BUILDING 1168

DIGITAL ANALOG DIGITAL ANALOG EMCS FUNCTIONS

EXISTING POINT AVAILABILITY:

8 / 8 UI POINTS USED

2 / 4 AO POINTS USED

3 / 8 DO POINTS USED

O U

T P

U T

I N

P U

T

O U

T P

U T

I N

P U

T

E Q

U I P

M E

A

T U

S

M A

I N

T E

N A

N C

E

P R

E S

S U

R E

H I G

H

L

I M

I T

L O

W

L

I M

I T

M A

I N

T E

N A

N C

E

D A

Y N

I G

T

B A

C K

S C

H E

D U

L E

D

S

T A

R T

S

T O

P

T O

T A

L I Z

A T

I O

N

T R

E N

D

F I R

E

A

L A

T E

G R

A T

I O

N

D R

Y B

U L

B

E

C O

N O

M I Z

E R

F I R

E

A

L A

E

R R

I D

E

Comments

POINT DESCRIPTION

AH-3 DISCHARGE AIR TEMP. X X X X AH-3 DAT

AH-3 PRE-FILTER X X AH-3 PFLT ON/OFF

AH-3 OUTSIDE AIR DAMPER SWITCH X X AH-3 DMSW ON/OFF

AH-3 FLOW STATUS X X X AH-3 FLO ON/OFF

AH3 FREEZE STATUS X X AH-3 FRZ ON/OFF

AH-3 SMOKE DETECTOR X X X AH-3 SMK ON/OFF

AH-3 FILTER PRESSURE DROP X X X AH-3 FLT IN WC

FIREALARM STATUS X X FIREALARM ON/OFF

HEATING COIL 5 VALVE POSITION X X HC 5 VALVE %

HEATING COIL 6 VALVE POSITION X X HC 6 VALVE %

AH-3 START/STOP X X AH-3 S/S ON/OFF

AH-3 EXHAUST AIR DAMPER X AH-3 EAD ON/OFF

EXHAUST AIR DAMPER X EX AIR DM ON/OFF

DDC INPUT / OUTPUT SUMMARY TABLE - MZ-06 (EXISTING)

PROJECT NO: FTQW 16-2602

PROJECT:

HARDWARE SOFTWARE

EIELSON AFB Repair EMCS & Meters

LOCATION:

POINTS ALARMS

BUILDING 1168

DIGITAL…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .