200129 Eielson EMCS Type B Final_STAMPED.pdf
PDF 19 MB Posted
- Attached to
- EMCS/DDC Recommissioning Federal contract opportunity
- Solicitation number
- W50S6K23Q0003
- Issued by
- Department of the Army National Guard
About this file
This file relates to a federal solicitation for EMCS/DDC recommissioning services. The Army National Guard is seeking proposals under solicitation number W50S6K23Q0003 to provide energy management control system and direct digital control system recommissioning at Eielson Air Force Base in Alaska. Offerors must have experience servicing similar control systems and be able to perform testing, calibration, programming, and staff training. Proposals are due by February 8, 2023 and the period of performance is expected to last approximately six months following award. The solicitation is designated as 100% small business set aside.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| DDC Recommissioning Q and A.pdf | ||
| 3. FTQW23-2101 Submittal Register.xlsx | XLSX spreadsheet | |
| 1. 168 WG Map.pdf | ||
| PWS FTQW23-2101 Recommission EMCS-DDC Systems v2.pdf | ||
| 2. CY23 168 WG Quick-Look Calendar_AWS & RSD.pdf | ||
| Combo EMCS-DDC Recommissioning (6July2023).pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ALASKA ANG REPAIR EMCS & METERS
EIELSON AIR FORCE BASE, ALASKA
01/29/2020
PROJECT NO. FTQW 16-2602
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C
S
M e t e r s
G-001
4259500-161602.01
COVER SHEET
JANUARY 29, 2020
SNW
RJH
AMT
X
T
E C
H C
A D
G
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
01/29/20 TYPE B FINAL
Sheet List Table
Sheet Number Sheet Title
G-001 COVER SHEET
M-001
SYMBOLS, ABBREVIATIONS, DETAILS AND SCHEDULES
M-002 OVERALL SITE PLAN
M-003 ENLARGED SITE UTILITY PLANS
M-101 BUILDING 1168 FLOOR PLANS
M-102 BUILDING 1171 FIRST FLOOR PLAN
M-103 BUILDING 1171 CATWALK LEVEL PLAN
M-104 BUILDING 1172 FIRST FLOOR PLAN
M-105 BUILDING 1173 FIRST FLOOR PLAN
M-106 BUILDING 1176 FIRST FLOOR PLAN
M-107 BUILDING 1176 SECOND FLOOR PLAN
M-108 BUILDING 3127 FIRST AND SECOND FLOOR PLANS
M-109 BUILDING 3127 THIRD FLOOR PLAN
M-110 BUILDING 3128 FIRST FLOOR PLAN
M-111 BUILDING 3129 FIRST FLOOR PLAN
M-112 BUILDING 3130 FIRST FLOOR PLAN
M-113 BUILDING 3131 FIRST FLOOR PLAN
M-114 BUILDING 3132 FIRST FLOOR PLAN
M-115 BUILDING 3133 FIRST FLOOR PLAN
M-116 BUILDING 3133 SECOND FLOOR PLAN
M-117 BUILDING 3180 FIRST FLOOR PLAN
M-118 BUILDING 3225 FIRST FLOOR PLAN
M-119 BUILDING 3225 SECOND FLOOR PLAN
M-120 BUILDING 32251 FIRST FLOOR PLAN
M-121 BUILDING 3345 FIRST FLOOR PLAN
M-601 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1168
M-602 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1168
M-603 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1171
M-604 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1171
M-605 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1171
M-606 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1172
M-607 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1173
M-608 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1176
M-609 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1176
M-610 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1176
M-611 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1176
M-612 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 1176
M-613 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3127
M-614 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3127
M-615 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3127
M-616 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3129
M-617 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3129
M-618 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3129
M-619 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3129
M-620 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3130
M-621 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3130
M-622 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3130
M-623 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3130
M-624 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3180
M-625 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3133
M-626 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3133
M-627 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3133
M-628 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3225
M-629 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3225
M-630 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3225
M-631 MECHANICAL DIGITAL CONTROL POINTS - BUILDING 3345
M-701 SYSTEM ARCHITECTURE
M-801
SYSTEM ARCHITECTURE ENLARGED - BLDGS 1168,1171,1172 & 1173
M-802
SYSTEM ARCHITECTURE ENLARGED - BLDGS 1176, 3127 & 3128
M-803 SYSTEM ARCHITECTURE ENLARGED - BLDGS 3129 AND 3130
M-804
SYSTEM ARCHITECTURE ENLARGED - BLDGS 3133, 3180, 3225, 3345
Robyn Henke
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-001
SYMBOLS,
ABBREVIATIONS,
DETAILS AND
SCHEDULES
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
ELECTRIC METER (EM) SCHEDULE
MARK
MANUFACTURER, MODEL NUMBER
VOLTAGE
FREQUENCY
ACCURACY
COMM PORT (2)
COMM PROTOCOL LOCATION REMARKS
EM-1168 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
EM-1168 HBO ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
EM-1171 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
EM-1172 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
EM-1173 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
EM-1176 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
EM-1176 HBO ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
EM-3127 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
EM-3129 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
EM-3130 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
EM-3133 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
EM-3180 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
EM-3225 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
EM-32251 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
EM-3345 ELECTRO-INDUSTRIES NEXUS 1272 120-480V 60Hz
0.5% (1)
ETHERNET MODBUS TCP/IP SEE PLANS
REMARKS:
(1) APPARENT POWER
(2) UNIT SHALL BE PROVIDED WITH MINIMUM (2) INTERNAL COMM PORTS FOR PULSE OUTPUT.
WATER METER (WM) SCHEDULE
MARK
MANUFACTURER, MODEL NUMBER
SIZE
(IN)
FLUID TYPE
DESIGN
PRESS.
(PSI)
FLUID
TEMP.
(°F)
DESIGN FLUID FLOW RATE
FLUID
SPECIFIC
GRAVITY LOCATION REMARKSMAX. MIN. UNITS
WM-1168
BADGER, TURBO 200
2 WATER 60 50 310 4 GPM 1 BLDG 1168
(3)
WM-1172
BADGER, MODEL 35
3/4 WATER 60 50 35 0.75 GPM 1 BLDG 1172
(2)
WM-1176
BADGER, TURBO 200
2 WATER 60 50 310 4 GPM 1 BLDG 1176
(1)
WM-3127
BADGER, TURBO 200
3 WATER 60 50 450 4 GPM 1 BLDG 3127
(1)
WM-3129
BADGER, TURBO 200
3 WATER 60 50 450 4 GPM 1 BLDG 3129
(1)
WM-3130
BADGER, TURBO 200
2 WATER 60 50 310 4 GPM 1 BLDG 3130
(1)
WM-3133
BADGER, TURBO 200
2 WATER 60 50 310 4 GPM 1 BLDG 3133
(1)
WM-3345
BADGER, TURBO 200
2 WATER 60 50 310 4 GPM 1 BLDG 3345
(1)
REMARKS:
(1) PROVIDE METER WITH ER420-LP TOTALIZER AND RATE OF FLOW INDICATOR FOR CONNECTION TO DDC SYSTEM.
(2) PROVIDE METER WITH HR-E 4-20 ENCODER AND RATE OF FLOW INDICATOR FOR CONNECTION TO DDC SYSTEM.
(3) PROVIDE METER WITH ER420-LP TOTALIZER AND REMOTE RATE OF FLOW INDICATOR FOR CONNECTION TO DDC SYSTEM. COORDINATE REMOTE
RATE OF FLOW INDICATOR LOCATION WITH OWNER.
CONDENSATE METER (CDM) SCHEDULE
MARK
MANUFACTURER, MODEL NUMBER
SIZE
(IN)
FLUID TYPE
DESIGN
PRESS.
(PSI)
FLUID
TEMP.
(°F)
DESIGN FLUID FLOW RATE
FLUID
SPECIFIC
GRAVITY LOCATION REMARKSMAX. MIN. UNITS
CDM-1176
BADGER, INDUSTRIAL TURBO
2 WATER 60 210 200 8 GPM 1 BLDG 1176
(1)
REMARKS:
(1) PROVIDE METER WITH MS-ER1 TOTALIZER PULSE TRANSMITTER AND SIX-DIGIT TOTALIZING REGISTER FOR CONNECTION TO DDC SYSTEM.
BACKFLOW PREVENTION DEVICE SCHEDULE
DESIGN CONDITIONS
ISOLATION VALVES MAXIMUM
SIZE FLOW PD BODY TEMP MAWP LENGTH
MARK
MFR, MODEL NUMBER
TYPE
(IN) (GPM) (PSID)
MTL TYPE MTL PORTS
(F) (PSIG) (IN) (2)
REMARKS
BPD-3130
WATTS, LF909M1
1013 2 75 10
BRZ (11)
BL
BRZ (11)
NPT 80.0 150.0 20.0
(31)(32)
TYPE ABBREVIATIONS
1012 DOUBLE CHECK VALVE ASSEMBLY WITH INTERMEDIATE ATMOSPHERIC BREAK IAW ASSE-1012
BL BALL
1013 REDUCED PRESSURE ZONE ASSEMBLY IAW ASSE-1013
GT-OSY
GATE, RESILIENT SEAT, OUTSIDE STEM AND YOKE
1015 DOUBLE CHECK VALVE ASSEMBLY IAW ASSE-1015
REMARKS:
(11) LEAD FREE
(31) PROVIDE INDIRECT DRAIN FROM VALVE TO DRAIN LOCATION. CONNECT DRAIN TO VALVE WITH AIR GAP
(32) SS RELIEF VALVE SEATS
NC
M
MAIN BYPASS
3/4" - 1-1/2" 3/4"
2" - 3" 1"
2"
3"
4"
4"
6"
8"
WATER SERVICE
MAIN
BYPASS. PIPE
SIZE PER TABLE
WATER METER PIPING (INFORMATIONAL ONLY)
NO SCALE
CONDUITS TO
TERMINAL
TOP VIEW
B
A
PROVIDE BUSHING ON ALL CONDUIT ENDS
PROVIDE MOUSE HOLE AS BOTTOMIN BASE (IN BOTTOM
SECTION IF STACKED)
CONDUIT DEPTH SHOWN IS APPROXIMATE. FIELD VERIFY TO
PROVIDE SLOPE IN CONDUIT AWAY FROM BUILDING.
POSITION HANDHOLE AND CONDUITS TO MAXIMIZE
DIMENSIONS "A" AND "B".
SEAL DUCTS/CONDUIT WITH 3M SCOTCHCAST 4416 TO
PREVENT ENTRY OF WATER INTO THE DUCTS. SEAL
OCCUPIED DUCTS FOLLOWING CABLE INSTALLATION.
DETAIL NOTES:
1.
2.
3.
4.
5.
INCOMING CONDUIT
NEW INGROUND
PULLBOX (HANDHOLE)
CROSS-SECTION A
HANDHOLE LID
PVC CONDUIT(S)
TO TERMINAL
POSITION CONCRETE
PAVER UNDER EACH
CORNER (4) OF HANDHOLE
TO PREVENT SETTLING.
SLOPE CONDUIT AWAY
FROM BUILDING.
BACKFILL TO WITHIN
2-INCHES OF
FINISHED GRADE
DIM "A"
BUILDING
INTERIOR
MOGUL-TYPE
LB FITTING
CONDUIT
12" BED OF COMPACTED
CRUSHED ROCK. EXTEND
ROCK 12" BEYOND PERIMETER
OF HANDHOLE ON ALL SIDES.
CROSS-SECTION B
CONDUITS FROM
PULLBOX TO BUILDING
INTERIOR
DIM "B"
BUILDING
EXTERIOR WALL
IMC CONDUIT TO
COMMUNICATIONS
ROOM OR OTHER
SPACE
UNDERGROUND BOX (HANDHOLD) DETAIL - TERMINAL ENTRANCE - PLN
NO SCALE
ELECTRIC METER
CT CONNECTIONS
VOLTAGE CONNECTIONS
F1
F2
F3
CT WIRING
VOLTAGE WIRING
(6-INPUTS)
(MAXIMUM)
RS485 TWISTED PAIR
CAT6 COPPER
EMCS
CONTROLLER
NEW
COMM RACK
EXISTING BUILDING MAIN POWER
NOTES:
1.
2.
THIS DIAGRAM IS FOR REFERENCE ONLY TO
ILLUSTRATE THE SYSTEM COMPONENTS OF THE
METERING SYSTEM.
SEE ALL DRAWING DETAILS AND SCHEMATICS
FOR PARTS, WIRING, AND INSTALLATION
DETAILS.
OVERALL METERING SYSTEM COMPONENT BLOCK DIAGRAM DETAIL
NO SCALE
OR ETHERNET
GROUND CUT AWAY
GENERAL NOTES:
1. THIS DETAIL REPRESENTS THE ENTIRE TRENCH AROUND BUILDING AND
ENCOMPASS MULTIPLE OBSTACLES FOUND IN TRENCH PATH. THIS
DETAIL IS FOR GENERAL REFERENCE AND DOES NOT REFER TO ONE
PARTICULAR LOCATION ON SITE
THIS SECTION REPRESENTS
PORTIONS OF TRENCH PASSING
THROUGH GRASSY/UN PAVED EARTH
BACKFILL AND COMPACT EARTH
AFTER CONDUIT IS INSTALLED
UNDISTURBED EARTH
UNDISTURBED PAVED SURFACE
30"
BACKFILL AND COMPACT EARTH TOPPED WITH COMPACTED
AGGREGATE BEFORE RESTORING ASPHALT SURFACE.
COORDINATE WITH FIELD CONDITIONS TO MATCH THICKNESS
OF ASPHALT AND DEPTH OF COMPACTED AGGREGATE BASE
36"
30"
CORE 8" INTO CONCRETE EVERY 12" ON CENTER. PLACE #5
REBAR BEDDED IN EPOXY PRIOR TO RESTORING CONCRETE
18"
DEPTH OF TRENCH
LAP REBAR 2" IN CENTER OF TRENCH
DIRECT BURIED CONDUIT
UNDISTURBED EARTH
BACKFILL AND COMPACT EARTH
AFTER CONDUIT IS INSTALLED
THIS SECTION REPRESENTS
PORTIONS OF TRENCH PASSING
THROUGH ASPHALT SURFACES
THIS SECTION REPRESENTS
PORTIONS OF TRENCH PASSING
THROUGH CONCRETE PAVING
MATCH THICKNESS OF CONCRETE PAVING IN FIELD
COMPACTED AGGREGATE DEPTH TO
MATCH THICKNESS OF
SURROUNDING PAVEMENT SECTION
18"
18"
IN ALL LOCATIONS
GROUND TRENCH DETAIL
NO SCALE
01/29/20 TYPE B FINAL
21.0°
28.5°
M-003
M-003
PARKING LOT HBO ELECTRIC METER
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-002
OVERALL SITE PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
ROAD
EXISTING PAVEMENT
SITE PLAN KEYED NOTES:
7.124 NEW UNDERGROUND CONDUIT MAY BE TRENCHED AND DIRECT BURIED OR
DIRECTIONALLY BORED. UNDERGROUND CONDUIT LOCATIONS SHALL BE
FIELD VERIFIED AND ADJUSTED AS NECESSARY TO AVOID OBSTRUCTIONS. SEE
DETAILS ON SHEET M-001.
7.125 SEE CONTINUATION ON SHEET M-108.
7.126 SEE CONTINUATION ON SHEET M-110.
7.127 SEE CONTINUATION ON SHEET M-113.
7.128 SEE CONTINUATION ON SHEET M-114.
7.129 SEE CONTINUATION ON SHEET M-112.
2" CONDUIT
(UNDERGROUND)
2" CONDUIT
(UNDERGROUND)
2" CONDUIT
(UNDERGROUND)
NEW HANDHOLE
APPROXIMATE LOCATION OF
EXISTING UNDERGROUND
ELECTRICAL FEED TO BLDG 3132
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-003
ENLARGED SITE
UTILITY PLANS
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
T
R
U
E
M
A
G
21.0°
28.5°
SITE UTILITY PLAN - ABI#1
1/8" = 1'-0"
SITE UTILITY PLAN - ABI#2
1/8" = 1'-0"
ELECTRIC METER (E)
FOR HBO'S
CONTROL PANELS (E)
COND. METER (E)
WATER METER
MAIN ELECTRIC METER
WM-1168
COMM RACK (E)
INSTALLED BENEATH
STAIR
EXISTING GCM
SUPERVISORY
CONTROLS
PANEL
MONACO FIRE PANEL (E)
PAINT BOOTH AHU-3 (E)
SHOP AHU-2 (E) (LOW)
ADMIN AHU-1 (E) (HIGH)
CONTROLS (E)
FLOOR PLAN KEYED NOTES:
7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE
LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET
PORT.
7.102 DEMOLISH EXISTING WATER METER. PROVIDE NEW METER IN SAME LOCATION
AS EXISTING. MODIFY PIPING AS NECESSARY TO ACCOMMODATE NEW METER.
SEE 3/M-101.
7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER
SHALL INTERFACE WITH DDC SYSTEM.
7.104 STEAM CONDENSATE, WATER AND ELECTRIC METER OUTPUTS SHALL BE
WIRED TO EXISTING MICROZONE CONTROLLERS MZ01, MZ02 AND MZ10. SEE
POINTS CHARTS ON SHEET M-601. PROVIDE WIRE AND CONDUIT REQUIRED TO
CONNECT ALL METERS TO EXISTING CONTROLLER(S).
7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED
AND WALL MOUNTED IN THE LOCATION SHOWN.
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-101
BUILDING 1168 FLOOR
PLANS
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 1168 FIRST FLOOR PLAN
1/8" = 1'-0"
BUILDING 1168 SECOND FLOOR PLAN
1/8" = 1'-0"
M
A
G
N T
R
U
E
N
28.5°
21.0°
BUILDING 1168 WATER METER EXISTING/DEMO
NO SCALE
COMM AND EXISTING
GCM SUPERVISORY
CONTROL PANELS
ELECTRIC METER
COND AND WATER METERS (E)
FIRE ALARM PANELS
AND EQUIPMENT
AIR COMPRESSOR (E)
ELEC (E)
CONTROLS (E)
GAS DETECTION CONTROLS (E)
FLOOR PLAN KEYED NOTES:
7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE
LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET PORT.
7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER
SHALL INTERFACE WITH DDC SYSTEM.
7.104 PROVIDE WIRE AND CONDUIT REQUIRED TO CONNECT ALL METERS TO EXISTING
CONTROLLER(S). STEAM CONDENSATE, WATER AND ELECTRIC METER OUTPUTS
SHALL BE WIRED TO EXISTING MICROZONE CONTROLLERS MZ17. SEE POINTS
CHARTS ON SHEET M-605.
7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED
AND WALL MOUNTED IN THE LOCATION SHOWN.
M-102
COMM RACK (E)
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-102
BUILDING 1171 FIRST
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
M
A
G
N T
R
U
E
N
28.5°
21.0°
BUILDING 1171 FIRST FLOOR PLAN
3/32" = 1'-0"
LARGE SCALE UTILITY RM 102.1
NO SCALE
EXISTING AHU CONTROLS
IN THIS AREA
(5) AHUs ON MEZZANINE
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-103
BUILDING 1171
CATWALK LEVEL PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
M
A
G
N T
R
U
E
N
28.5°
21.0°
BUILDING 1171 CATWALK LEVEL PLAN
3/32" = 1'-0"
FIRE ALARM (E)
CONTROLS (E)
COND METER (E)
AHU (E) ON MEZZANINE
MAIN ELECTRIC METER
WM-1172
FLOOR PLAN KEYED NOTES:
7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER
SHALL INTERFACE WITH DDC SYSTEM.
7.104 PROVIDE WIRE AND CONDUIT REQUIRED TO CONNECT ALL METERS TO EXISTING
CONTROLLER(S). STEAM CONDENSATE, WATER AND ELECTRIC METER OUTPUTS
SHALL BE WIRED TO EXISTING MICROZONE CONTROLLER MZ19. SEE POINTS
CHART ON SHEET M-606.
7.105 PROVIDE NEW WATER METER IN EXISTING WATER MAIN. MODIFY PIPING AS
NECESSARY TO ACCOMMODATE NEW METER.
7.118 EXISTING MICROZONE CONTROLS ARE ASSOCIATED WITH GCM SUPERVISORY
CONTROLLER IN BLDG 1171. MAINTAIN ASSOCIATION BETWEEN THESE
CONTROLS AND THE NEW SUPERVISORY CONTROLLER IN BLDG 1171.
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-104
BUILDING 1172 FIRST
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
T
R
U
E
M
A
G
21.0°
28.5°
BUILDING 1172 FIRST FLOOR PLAN
1/4" = 1'-0"
FIRE ALARM
ELEC PANEL (E)
ELEC METER
CONTROLS
COND METER (E)
FLOOR PLAN KEYED NOTES:
7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER
SHALL INTERFACE WITH DDC SYSTEM.
7.104 PROVIDE WIRE AND CONDUIT REQUIRED TO CONNECT ALL METERS TO EXISTING
CONTROLLER(S). STEAM CONDENSATE IS WIRED TO MZ13 AND SHALL BE
INTEGRATED INTO NEW FRONT END. ELECTRIC METER OUTPUTS SHALL BE
WIRED TO EXISTING MICROZONE CONTROLLER MZ15. SEE POINTS CHART ON
SHEET M-607.
7.118 EXISTING MICROZONE CONTROLS ARE ASSOCIATED WITH GCM SUPERVISORY
CONTROLLER IN BLDG 1171. MAINTAIN ASSOCIATION BETWEEN THESE
CONTROLS AND THE NEW SUPERVISORY CONTROLLER IN BLDG 1171.
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-105
BUILDING 1173 FIRST
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
T
R
U
E
M
A
G
BUILDING 1173 FIRST FLOOR PLAN
1/4" = 1'-0"
ELEC METER (E)
COMM ROOM
COND METER (E)
WATER METER
EXISTING STEAM EQUIP
FOR THIS SIDE OF
BUILDING
EXISTING FIRE PANEL AND
PUMP CONTROLS
FIRE PUMP (E)
COMM (E) IN THIS AREA
OUTSIDE LIGHT
CONTACT (E)
SMALL AHU (E) FOR ELEC COOLING
CONTROL
PANEL (E)
CONTROL
PANEL (E)
EXISTING MAIN STEAM MECH FOR
THIS SIDE
NEW CONTROLLER
CDM-1176
FLOOR PLAN KEYED NOTES:
7.102 DEMOLISH EXISTING WATER METER. PROVIDE NEW METER IN SAME LOCATION
AS EXISTING. MODIFY PIPING AS NECESSARY TO ACCOMMODATE NEW METER.
7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER
SHALL INTERFACE WITH DDC SYSTEM.
7.104 PROVIDE NEW CONTROLLER FOR COLLECTION OF DATA FROM STEAM
CONDENSATE, WATER AND ELECTRICAL METERS. FIELD VERIFY LOCATION
FOR NEW CONTROLLER. PROVIDE WIRE AND CONDUIT REQUIRED TO
CONNECT ALL METERS TO NEW CONTROLLER. PROVIDE ELECTRICAL POWER
AND TRANSFORMERS NECESSARY FOR NEW CONTROLLER OPERATION.
7.106 PROVIDE NEW CONDENSATE METER IN EXISTING CONDENSATE MAIN. MODIFY
PIPING AS NECESSARY TO ACCOMMODATE NEW METER. SEE 2/M-106.
7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED
AND WALL MOUNTED IN THE LOCATION SHOWN.
CONDENSATE PUMP (E)
EXISTING 2" CONDENSATE
FROM EAST MECH RM
REMOTE ENCLOSURE
CONTAINING ELECTRICAL
METER FOR PARKING LOT
HBO'S (SEE SHEET M-002)
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-106
BUILDING 1176 FIRST
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 1176 FIRST FLOOR PLAN
1/16" = 1'-0"
T
R
U
E
M
A
G
CONDENSATE PIPE DEMOLITION
NO SCALE
CONTROL PANELS (E) FOR
AIRPLANE WASH SYSTEMS
HEAT TRACE CONTROL (E)
ADMIN AHU-9 (E)
EXISTING GCM SUPERVISORY
CONTROL PANEL
AHU-3 (E)
AHU-10 (E)
CONTROLS (E)
RADIANT FLOOR EQUIPMENT (E)
AHU-1 (E)
CONTROL PANELS (E)
AHU-11 (E)
AHU-12 (E)
AHU-4 (E)
RADIANT FLOOR EQUIPMENT (E)
AHU-2 (E)
AHU-15 (E)
AHU-8 (E)
CONTROLS (E)
SHOP AHU-7 (E)
BATTERY AHU-13 (E)
AHU-5 (E)
HEAT
TRACE
CONTROLS
(E)
EXISTING AHU
(ABANDONED)
AHU-6 (E)
CONTROLS (E)
FLOOR PLAN KEYED NOTES:
7.101 REMOVE EXISTING AND INSTALL NEW SUPERVISORY CONTROLLER IN THE
LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET
PORT.
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-107
BUILDING 1176
SECOND FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 1176 SECOND FLOOR PLAN
1/16" = 1'-0"
T
R
U
E
M
A
G
EXISTING ELEC
EXISTING COMM CLOSET
STEAM COND METER (E)
CONTROL
PANEL (E)
MONACO FIRE ALARM (E)
ELEC GEAR
GCM SUPERVISORY CONTROL PANEL
FLOOR PLAN KEYED NOTES:
7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE
LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET
PORT.
7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER
SHALL INTERFACE WITH DDC SYSTEM.
7.104 PROVIDE WIRE AND CONDUIT REQUIRED TO CONNECT ALL METERS TO
EXISTING CONTROLLER(S). STEAM CONDENSATE, WATER AND ELECTRIC
METER OUTPUTS SHALL BE WIRED TO EXISTING MICROZONE CONTROLLER
MZ02 OR MZ14. SEE POINTS CHART ON SHEET M-613 AND M-615.
7.105 PROVIDE NEW WATER METER IN EXISTING WATER MAIN. MODIFY PIPING AS
NECESSARY TO ACCOMMODATE NEW METER.
7.108 NEW CONTROL PANEL FOR TERMINATION OF COMMUNICATIONS CABLE FROM
BUILDING 3128. TERMINATE CABLE FOR FUTURE USE.
7.114 NEW UNDERGROUND TEMPERATURE CONTROLS CABLE. SEE SITE PLAN M-003
FOR CONTINUATION.
7.115 NEW IN-GROUND HAND-HOLE FOR ROUTING OF NEW TEMPERATURE
CONTROLS CABLE BETWEEN BUILDINGS.
7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED
AND WALL MOUNTED IN THE LOCATION SHOWN.
EXISTING WATER SERVICE
ENTRANCE
WM-3127 (IN VERTICAL)
ALL WORK WITHIN
CLOUDED REGION TO BE
PART OF ABI #1
ABI #1
AHU (E)AHU (E)
VFDs (E)
CONTROLS (E) (MZ-3, MZ-4 & MZ-9)
EXISTING COMM ROOM
VFDs (E)
AHU (E)AHU (E)
CONTROLS (E)
(MZ-10, MZ-11 &
MZ-12)
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-108
BUILDING 3127 FIRST
AND SECOND FLOOR
PLANS
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 3127 FIRST FLOOR PLAN
1/8" = 1'-0"
T
R
U
E
M
A
G
BUILDING 3127 SECOND FLOOR PLAN
1/8" = 1'-0"
VFDs (E)
AHU (E)
AHU (E)
CONTROLS (E) (MZ-7 & MZ-8)
EXISTING COMM ROOM
CONTROLS (E) (MZ-5 & MZ-6)
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-109
BUILDING 3127 THIRD
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 3127 THIRD FLOOR PLAN
1/8" = 1'-0"
T
R
U
E
M
A
G
CONTROL PANEL
FLOOR PLAN KEYED NOTES:
7.107 NEW MIN. 24"X24" CONTROL PANEL FOR TERMINATION OF COMMUNICATIONS
CABLE FROM BLDG 3127. TERMINATE CABLE FOR FUTURE USE.
7.114 NEW UNDERGROUND TEMPERATURE CONTROLS CABLE. SEE SITE PLAN M-003
FOR CONTINUATION.
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-110
BUILDING 3128 FIRST
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 3128 FIRST FLOOR PLAN - ABI #1
1/4" = 1'-0"
T
R
U
E
M
A
G
21.0°
28.5°
ALL WORK ON THIS SHEET IS FOR ABI #1
EXISTING COMM ROOM
FIRE PANEL (E)
EXISTING MEZZANINE
PANEL (E)
PANEL (E)
AHU-5 (E)
AHU-3 (E)
AHU-4 (E)
AHU-2 (E) W/VFD
EXISTING MEZZANINE
PANELS (E)
VFDs (E)
EXISTING COMM RACK
ELECTRICAL SERVICE
COND METER (E)
PANELS (E)
EXISTING MEZZANINE
EXISTING MEZZANINE
FIRE PANEL (E) (MAIN)
CONTROL PANEL
AHU-1 (E)
WATER METER
NEW CONTROLLER
FLOOR PLAN KEYED NOTES:
7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE
LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET PORT.
7.102 DEMOLISH EXISTING WATER METER. PROVIDE NEW METER IN SAME LOCATION
AS EXISTING. MODIFY PIPING AS NECESSARY TO ACCOMMODATE NEW METER.
SEE 2/M-111.
7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR, WITHIN
FIBERGLASS ENCLOSURE. NEW METER SHALL INTERFACE WITH DDC SYSTEM.
7.104 PROVIDE NEW CONTROLLER FOR COLLECTION OF DATA FROM STEAM
CONDENSATE, WATER AND ELECTRICAL METERS. FIELD VERIFY LOCATION
FOR NEW CONTROLLER. PROVIDE WIRE AND CONDUIT REQUIRED TO
CONNECT ALL METERS TO NEW CONTROLLER. PROVIDE ELECTRICAL POWER
AND TRANSFORMERS NECESSARY FOR NEW CONTROLLER OPERATION.
7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED
AND WALL MOUNTED IN THE LOCATION SHOWN.
7.119 BASE STAFF INDICATES THAT THE INLET ISOLATION VALVE FOR WATER METER
IS DAMAGED AND INOPERABLE. PROVIDE NEW ISOLATION VALVE. COORDINATE
WITH THE BASE TO ARRANGE SHUTOFF OF WATER TO THE FACILITY.
7.125 PROVIDE NEW 2" DIRECT BURIED UNDERGROUND CONDUIT AND TEMPERATURE
CONTROLS CABLE TO CONNECT NEW ELECTRICAL METER AND NEW
CONTROLLER. COORDINATE CONDUIT LOCATION WITH EXISTING ELECTRICAL
SERVICE.
WM-3129
GCM SUPERVISORY CONTROLLER
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-111
BUILDING 3129 FIRST
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 3129 FIRST FLOOR PLAN
3/32" = 1'-0"
T
R
U
E
M
A
G
21.0°
28.5°
3129 WATER METER EXISTING/DEMO
NO SCALE
MAU-1 (E)
CONNECTED TO
CO SENSORS
EXISTING MEZZANINE
AHU-3 (E)
GCM SUPERVISORY
CONTROL PANEL
EXISTING MEZZANINE
FIRE PANEL (E)
EXISTING AHU-2 (ABANDONED IN PLACE)
AHU-1 (E)
EXISTING MEZZANINE
CONTROL
PANELS (E)
COND METER (E)
EXISTING COMM ROOM
CONTROL
PANELS (E)
NEW CONTROLLER
WATER METER
WM-3130
CONTROL PANEL
FLOOR PLAN KEYED NOTES:
7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE
LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET PORT.
7.102 DEMOLISH EXISTING WATER METER. PROVIDE NEW METER IN SAME LOCATION
AS EXISTING. MODIFY PIPING AS NECESSARY TO ACCOMMODATE NEW METER.
7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER
SHALL INTERFACE WITH DDC SYSTEM.
7.104 PROVIDE NEW CONTROLLER FOR COLLECTION OF DATA FROM STEAM
CONDENSATE, WATER AND ELECTRICAL METERS. FIELD VERIFY LOCATION
FOR NEW CONTROLLER. PROVIDE WIRE AND CONDUIT REQUIRED TO
CONNECT ALL METERS TO NEW CONTROLLER.
7.108 NEW CONTROL PANEL FOR TERMINATION OF COMMUNICATIONS CABLE FROM
BUILDINGS 3131 AND 3132. TERMINATE CABLE FOR FUTURE USE.
7.114 NEW UNDERGROUND TEMPERATURE CONTROLS CABLE. SEE SITE PLAN M-003
FOR CONTINUATION.
7.115 NEW IN-GROUND HAND-HOLE FOR ROUTING OF NEW TEMPERATURE CONTROLS
CABLE BETWEEN BUILDINGS.
7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED
AND WALL MOUNTED IN THE LOCATION SHOWN.
7.118 PROVIDE NEW BACKFLOW PREVENTION DEVICE IN EXISTING COLD WATER
SERVICE. MODIFY PIPING AS NECESSARY TO ACCOMMODATE NEW BPD. REFER
TO 2/M-112.
EXISTING PORTS RACKS
BACKFLOW PREVENTER
BPD-3130
2" CW
WATER SERVICE (E)
ALL WORK WITHIN
CLOUDED REGION TO BE
PART OF ABI #2
ABI #2
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-112
BUILDING 3130 FIRST
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 3130 FIRST FLOOR PLAN
3/32" = 1'-0"
T
R
U
E
M
A
G
21.0°
28.5°
BUILDING 3130 WATER METER EXISTING CONDITIONS
NO SCALE
FIRE PANEL (E)
FLOOR PLAN KEYED NOTES:
7.109 NEW MIN. 24" x 24" CONTROL PANEL FOR TERMINATION OF COMMUNICATIONS
CABLE FROM BLDG 3130. TERMINATE CABLE FOR FUTURE USE.
7.114 NEW UNDERGROUND TEMPERATURE CONTROLS CABLE AND CONDUIT. SEE
SITE PLAN M-003 FOR CONTINUATION.
7.115 NEW UNDERGROUND CONDUIT FOR ROUTING OF NEW TEMPERATURE
CONTROLS CABLE BETWEEN BUILDINGS.
7.116 TEMPERATURE CONTROLS CABLE AND CONDUIT FROM NEW CONTROL PANEL
DOWN TO UNDERGROUND CONDUIT. CABLE RUNS FROM BLDG 3130.
NEW TEMPERATURE CONTROL
CABLE AND CONDUIT
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-113
BUILDING 3131 FIRST
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 3131 FIRST FLOOR PLAN - ABI #2
1/2" = 1'-0"
T
R
U
E
M
A
G
21.0°
28.5°
ALL WORK ON THIS SHEET IS FOR ABI #2
FLOOR PLAN KEYED NOTES:
7.109 NEW MIN. 24" x 24" CONTROL PANEL FOR TERMINATION OF COMMUNICATIONS
CABLE FROM BLDG 3130. TERMINATE CABLE FOR FUTURE USE.
7.114 NEW UNDERGROUND TEMPERATURE CONTROLS CABLE AND CONDUIT. SEE SITE
PLAN M-003 FOR CONTINUATION. CABLE RUNS FROM BLDG 3130.
7.116 TEMPERATURE CONTROLS CABLE AND CONDUIT FROM NEW CONTROL PANEL
DOWN TO UNDERGROUND CONDUIT.
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-114
BUILDING 3132 FIRST
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 3132 FIRST FLOOR PLAN - ABI #2
1/4" = 1'-0"
T
R
U
E
M
A
G
21.0°
28.5°
ALL WORK ON THIS SHEET IS FOR ABI #2
GCM SUPERVISORY
CONTROL PANELS
WATER METER
WM-3133
ELECTRIC METER
EXISTING
CONTROLS FOR
SHOP SYSTEMS
CONTROL CABINET (E) (LOW)
CONTROL CABINET (E) (HIGH)
AHU (E)
FLOOR PLAN KEYED NOTES:
7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE
LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET
PORT.
7.102 DEMOLISH EXISTING WATER METER. PROVIDE NEW METER IN SAME LOCATION
AS EXISTING. MODIFY PIPING AS NECESSARY TO ACCOMMODATE NEW METER.
SEE 2/M-115.
7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER
SHALL INTERFACE WITH DDC SYSTEM.
7.104 PROVIDE WIRE AND CONDUIT REQUIRED TO CONNECT ALL METERS TO
EXISTING CONTROLLER(S). WATER METER OUTPUT SHALL BE WIRED TO
EXISTING MICROZONE CONTROLLER MZ01. SEE POINTS CHART ON
SHEET M-625. ELECTRIC METER OUTPUT SHALL BE WIRED TO EXISTING
MICROZONE CONTROLLER MZ13. SEE POINTS CHART ON SHEET M-627.
7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED
AND WALL MOUNTED IN THE LOCATION SHOWN.
EXISTING COMM RACK
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-115
BUILDING 3133 FIRST
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 3133 FIRST FLOOR PLAN
1/8" = 1'-0"
T
R
U
E
M
A
G
3133 WATER METER EXISTING/DEMO
NO SCALE
AHU-2 (E)
AHU-1 (E)
CONTROL PANELS (E)
COND METER (E)
STEAM
PRVs (E)
LIGHTING
CONTROLS (E)
EXISTING FIRE PANEL &
MAIN MECH
FLOOR PLAN KEYED NOTES:
7.104 PROVIDE WIRE AND CONDUIT REQUIRED TO CONNECT ALL METERS TO EXISTING
CONTROLLER(S). STEAM CONDENSATE SHALL BE WIRED TO EXISTING
MICROZONE CONTROLLER MZ04. SEE POINTS CHART ON SHEET M-625.
PARKING LOT
HBO CONTROLS
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-116
BUILDING 3133
SECOND FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 3133 SECOND FLOOR PLAN
1/8" = 1'-0"
T
R
U
E
M
A
G
ELEC METER (E)
VFDs (E)
FIRE PANELS (E)
WATER METER (E)
STEAM CONDENSATE METER (E)
STRUCTURE WARE
CONTROL PANEL (E)
ERV (E)
LIEBERT ENERGY MANAGER
SERVES RM113 & RM116 (E)
LIEBERT
CONTROLS (E)
FLOOR PLAN KEYED NOTES:
7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE
LOCATION INDICATED.
7.110 INTEGRATE EXISTING SMART ELECTRIC METER INTO DDC SYSTEM.
7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED
AND WALL MOUNTED IN THE LOCATION SHOWN.
7.120 INTEGRATE EXISTING SMART WATER METER INTO NEW DDC SYSTEM.
7.121 INTEGRATE EXISTING SMART CONDENSATE METER INTO NEW DDC SYSTEM.
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-117
BUILDING 3180 FIRST
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 3180 FIRST FLOOR PLAN
1/8" = 1'-0"
T
R
U
E
M
A
G
21.0°
28.5°
AHU ON MEZZANINE (E)
AHU-3 ON MEZZANINE (E)
EXISTING GCM SUPERVISORY CONTROL PANELS
VFD (E)
WATER METER (E)
STEAM CONDENSATE METER (E)
FIRE ALARM PANEL (E)
ELEC METER (E)
EMCS OPERATOR WORKSTATION (E)
NEW CONTROLLER
FLOOR PLAN KEYED NOTES:
7.101 REMOVE EXISTING AND INSTALL NEW SUPERVISORY CONTROLLER IN THE
LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET
PORT.
7.103 INSTALL NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER
SHALL INTERFACE WITH DDC SYSTEM.
7.104 PROVIDE NEW CONTROLLER FOR COLLECTION OF DATA FROM ELECTRICAL
METER. FIELD VERIFY LOCATION FOR NEW CONTROLLER. PROVIDE WIRE AND
CONDUIT REQUIRED TO CONNECT METER TO NEW CONTROLLER.
7.111 PROVIDE WIRELESS COMMUNICATION POINT FOR DDC COMMUNICATION WITH
BLDG 32251. PROVIDE ETHERNET COMMUNICATIONS LINK WITH NEW DDC
SYSTEM. PROVIDE POINT-TO-POINT BRIDGE SIMILAR TO CAMBIUM NETWORKS
PTP-700.
7.122 COORDINATE LOCATION FOR INSTALLATION OF NEW OPERATOR
WORKSTATION AND CONTROLS SERVER.
7.123 EXISTING WATER METER IS WIRED TO COMMUNICATE WITH EXISTING DDC
SYSTEM. VERIFY COMMUNICATIONS INSTALLATION OF WATER METER.
ALL WORK WITHIN
CLOUDED REGION TO BE
PART OF ABI #3
ABI #3
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-118
BUILDING 3225 FIRST
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 3225 FIRST FLOOR PLAN
1/8" = 1'-0"
TRUE
M
A
G
AHU-2 (E)
NETWORK COMM RACK (E)
CONTROL PANELS (E)
FLOOR PLAN KEYED NOTES:
7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED
AND WALL MOUNTED IN THE LOCATION SHOWN.
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-119
BUILDING 3225
SECOND FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 3225 SECOND FLOOR PLAN
1/8" = 1'-0"
TRUE
M
A
G
ELEC & FIRE ALARM PANELS (E)
FLOOR PLAN KEYED NOTES:
7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER
SHALL INTERFACE WITH DDC SYSTEM.
7.112 PROVIDE WIRELESS COMMUNICATION POINT FOR DDC COMMUNICATION WITH
BLDG 3225. PROVIDE SIMILAR TO CAMBIUM NETWORKS PTP-700.
7.113 NEW MIN. 24"X24" CONTROL PANEL FOR TERMINATION OF CABLE FROM
WIRELESS SYSTEM. TERMINATE FOR FUTURE USE.
ALL WORK WITHIN
CLOUDED REGION TO BE
PART OF ABI #3
ABI #3
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-120
BUILDING 32251 FIRST
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 32251 FIRST FLOOR PLAN
1/4" = 1'-0"
T
R
U
E
M
A
G
21.0°
28.5°
FIRE ALARM (E)
NETWORK COMM RACK (E)
EXISTING GCM
SUPERVISORY
CONTROLS
AHU-1 (E)
ELEC METER
VFD (E)
STEAM
CONDENSATE
METER (E)
WATER METER
MAIN MECH
FLOOR PLAN KEYED NOTES:
7.101 REMOVE EXISTING AND PROVIDE NEW SUPERVISORY CONTROLLER IN THE
LOCATION INDICATED. REUSE EXISTING POWER SOURCE AND ETHERNET PORT.
7.102 DEMOLISH EXISTING WATER METER. PROVIDE NEW METER IN SAME LOCATION
AS EXISTING. MODIFY PIPING AS NECESSARY TO ACCOMMODATE NEW METER.
SEE 2/M-121.
7.103 PROVIDE NEW ELECTRIC METER IN EXISTING ELECTRICAL GEAR. NEW METER
SHALL INTERFACE WITH DDC SYSTEM.
7.104 PROVIDE WIRE AND CONDUIT REQUIRED TO CONNECT ALL METERS TO EXISTING
CONTROLLER(S). STEAM CONDENSATE IS WIRED TO MZ04 AND SHALL BE
INTEGRATED INTO NEW FRONT END. ELECTRIC METER AND WATER METER
OUTPUTS SHALL BE WIRED TO EXISTING MICROZONE CONTROLLER MZ04. SEE
POINTS CHART ON SHEET M-631.
7.117 NEW NETWORK EQUIPMENT (SWITCHES, ROUTERS, ETC.) SHALL BE PROVIDED
AND WALL MOUNTED IN THE LOCATION SHOWN.
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-121
BUILDING 3345 FIRST
FLOOR PLAN
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
BUILDING 3345 FIRST FLOOR PLAN
3/16" = 1'-0"
T
R
U
E
M
A
G
21.0°
28.5°
3345 WATER METER EXISTING/DEMO
NO SCALE
T a n k e r
R d
A l a s k a
A
N G
R e p a i r
E
M C t e
M-601
MECHANICAL DIGITAL
CONTROL POINTS -
BUILDING 1168
JANUARY 29, 2020
SNW
RRW
AMT
X
T
E C
H C
A D
M
D
W G
P
M
E i e l s o n
A
F B
A
K
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
of
SHEET NO.
© Copyright
This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead &
Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead and Hunt, Inc.
9600 NE Cascades Parkway, Suite 100
Portland, OR 97220 phone: 503-548-1494 meadhunt.com
DDC INPUT / OUTPUT SUMMARY TABLE - MZ-01 (EXISTING)
PROJECT NO: FTQW 16-2602
PROJECT:
HARDWARE SOFTWARE
EIELSON AFB Repair EMCS & Meters
LOCATION:
POINTS ALARMS
BUILDING 1168
DIGITAL ANALOG DIGITAL ANALOG EMCS FUNCTIONS
EXISTING POINT AVAILABILITY:
8 / 8 UI POINTS USED
2 / 4 AO POINTS USED
6 / 8 DO POINTS USED
O U
T P
U T
I N
P U
T
O U
T P
U T
I N
P U
T
E Q
U I P
M E
N T
A
T U
S
M A
I N
T E
N A
N C
E
P R
E S
S U
R E
H I G
H
L
I M
I T
L O
W
L
I M
I T
M A
I N
T E
N A
N C
E
D A
Y N
I G
H
E T
B A
C K
S C
H E
D U
L E
D
S
T A
R T
S
T O
P
T O
T A
L I Z
A T
I O
N
T R
E N
D
F I R
E
A
L A
R
I
T E
G R
A T
I O
N
D R
Y B
U L
B
E
C O
N O
M I Z
E R
F I R
E
A
L A
O
V E
R R
I D
E
Comments
POINT DESCRIPTION
OUTSIDE AIR TEMP. X X OAT
GLYCOL HOT WATER RETURN TEMP. X X X X GHWR TMP
GLYCOL HOT WATER SUPPLY TEMP. X X X X GHWS TMP
CIRCULATING PUMP 1 FLOW STATUS X X X CP-1 FLO ON/OFF
CIRCULATING PUMP 2 FLOW STATUS X X X CP-2 FLO ON/OFF
CIRCULATING PUMP 3 FLOW STATUS X X X CP-3 FLO ON/OFF
CIRCULATING PUMP 4 FLOW STATUS X X X CP-4 FLO ON/OFF
CIRCULATING PUMP 1 START/STOP X X CP-1 S/S ON/OFF
CIRCULATING PUMP 2 START/STOP X X CP-2 S/S ON/OFF
CIRCULATING PUMP 3 START/STOP X X CP-3 S/S ON/OFF
CIRCULATING PUMP 4 START/STOP X X CP-4 S/S ON/OFF
HX-1 CONTROL VALVE 1 POSITION X X HX-1 CV-1 %
HX-1 CONTROL VALVE 2 POSITION X X HX-1 CV-2 %
FAILSAFE X X FAILSAFE
FAILSAFE X X FAILSAFE
WATER METER X X X NEW POINT
DDC INPUT / OUTPUT SUMMARY TABLE - MZ-02 (EXISTING)
PROJECT NO: FTQW 16-2602
PROJECT:
HARDWARE SOFTWARE
EIELSON AFB Repair EMCS & Meters
LOCATION:
POINTS ALARMS
BUILDING 1168
DIGITAL ANALOG DIGITAL ANALOG EMCS FUNCTIONS
EXISTING POINT AVAILABILITY:
8 / 8 UI POINTS USED
2 / 4 AO POINTS USED
4 / 8 DO POINTS USED
O U
T P
U T
I N
P U
T
O U
T P
U T
I N
P U
T
E Q
U I P
M E
A
T U
S
M A
I N
T E
N A
N C
E
P R
E S
S U
R E
H I G
H
L
I M
I T
L O
W
L
I M
I T
M A
I N
T E
N A
N C
E
D A
Y N
I G
T
B A
C K
S C
H E
D U
L E
D
S
T A
R T
S
T O
P
T O
T A
L I Z
A T
I O
N
T R
E N
D
F I R
E
A
L A
T E
G R
A T
I O
N
D R
Y B
U L
B
E
C O
N O
M I Z
E R
F I R
E
A
L A
E
R R
I D
E
Comments
POINT DESCRIPTION
GLYCOL SYSTEM PRESSURE X X X X G-S PSI
CIRCULATING PUMP 5 STATUS X X X CP-5 FLO ON/OFF
CIRCULATING PUMP 5 STATUS X X X CP-6 FLO ON/OFF
SUPPLY FAN 2 DISCHARGE AIR TEMP. X X X X SF-2 DAT
ROOM 115 TEMP. X X X X R115 TMP
ROOM 114 TEMP. X X X X R114 TMP
DOMESTIC HOT WATER HEATER TEMP. X X X X DHWH TMP
SUPPLY FAN 2 DAMPER POSITION X X SF-2 DMPES %
DOMESTIC HOT WATER HEATER CONTROL VALVE POSITION X X DHWH CV %
CIRCULATING PUMP 5 START/STOP X X CP-5 S/S ON/OFF
ROOM 115 UNIT HEATER START/STOP X X UH-115 S/S ON/OFF
SUPPLY FAN 2 START/ STOP X X SF-2 S/S ON/OFF
ROOM 114 CONTROL VALVE X X R114 CV ON/OFF
ELECTRICAL METER X X X NEW POINT
DDC INPUT / OUTPUT SUMMARY TABLE - MZ-03 (EXISTING)
PROJECT NO: FTQW 16-2602
PROJECT:
HARDWARE SOFTWARE
EIELSON AFB Repair EMCS & Meters
LOCATION:
POINTS ALARMS
BUILDING 1168
DIGITAL ANALOG DIGITAL ANALOG EMCS FUNCTIONS
EXISTING POINT AVAILABILITY:
8 / 8 UI POINTS USED
4 / 4 AO POINTS USED
2 / 8 DO POINTS USED
O U
T P
U T
I N
P U
T
O U
T P
U T
I N
P U
T
E Q
U I P
M E
A
T U
S
M A
I N
T E
N A
N C
E
P R
E S
S U
R E
H I G
H
L
I M
I T
L O
W
L
I M
I T
M A
I N
T E
N A
N C
E
D A
Y N
I G
T
B A
C K
S C
H E
D U
L E
D
S
T A
R T
S
T O
P
T O
T A
L I Z
A T
I O
N
T R
E N
D
F I R
E
A
L A
T E
G R
A T
I O
N
D R
Y B
U L
B
E
C O
N O
M I Z
E R
F I R
E
A
L A
E
R R
I D
E
Comments
POINT DESCRIPTION
AH-1 DISCHARGE AIR TEMP. X X X X AH-1 DAT
AH-1 MIXED AIR TEMP. X X X X AH-1 MAT
AH-1 RETURN AIR TEMP. X X X X AH-1 RAT
AH-1 FLOW STATUS X X X AH1 FLO ON/OFF
AH-1 FREEZE STATUS X X X AH-1 FRZ
WINTER FILTER PRESSURE DROP X X X WINFILTER
AH-1 FILTER X X X FILTER
AH-1 OVERRIDE X X OVRRID ON/OFF
AH-1 PREHEAT CONTROL VALVE POSITION X X AH-1 PH CV %
AH-1 HEATING CONTROL VALVE POSITION X X AH-1 H CV %
AH-1 MIXED AIR DAMPER POSITION X X AH-1 MAD %
AH-1 EXHAUST AIR DAMPER POSITION X X AH-1 EAD %
AH-1 START/STOP X X AH-1 S/S ON/OFF
FIRE/SMOKE DAMPER X FS DMP ON/OFF
DDC INPUT / OUTPUT SUMMARY TABLE - MZ-04 (EXISTING)
PROJECT NO: FTQW 16-2602
PROJECT:
HARDWARE SOFTWARE
EIELSON AFB Repair EMCS & Meters
LOCATION:
POINTS ALARMS
BUILDING 1168
DIGITAL ANALOG DIGITAL ANALOG EMCS FUNCTIONS
EXISTING POINT AVAILABILITY:
8 / 8 UI POINTS USED
3 / 4 AO POINTS USED
4 / 8 DO POINTS USED
O U
T P
U T
I N
P U
T
O U
T P
U T
I N
P U
T
E Q
U I P
M E
A
T U
S
M A
I N
T E
N A
N C
E
P R
E S
S U
R E
H I G
H
L
I M
I T
L O
W
L
I M
I T
M A
I N
T E
N A
N C
E
D A
Y N
I G
T
B A
C K
S C
H E
D U
L E
D
S
T A
R T
S
T O
P
T O
T A
L I Z
A T
I O
N
T R
E N
D
F I R
E
A
L A
T E
G R
A T
I O
N
D R
Y B
U L
B
E
C O
N O
M I Z
E R
F I R
E
A
L A
E
R R
I D
E
Comments
POINT DESCRIPTION
AH-2 DISCHARGE AIR TEMP. X X X X AH-2 DAT
FILTER DIFFERENTIAL PRESSURE SWITCH X X X SUM FLTR ON/OFF
AH-2 DISCHARGE PRESSURE X X X AH-2 DPRS IN WC
AH-2 CURRENT SWITCH X X X AH-2 CT ON/OFF
AH-2 FREEZE STATUS X X AH-2 FRZ ON/OFF
AH-2 SMOKE DETECTOR X X X AH-2 SMK ON/OFF
FILTER PRESSURE DROP X X X FILTER IN WC
AH-2 OUTSIDE AIR DAMPER SWITCH X X AH-2 DMSW ON/OFF
HEATING COIL 3 VALVE POSITION X X HC-3 VLV %
HEATING COIL 4 VALVE POSITION X X HC-4 VLV %
AH-2 FAN SPEED X AH-2 SPEED %
AH-2 START/STOP X X AH-2 S/S ON/OFF
FIRE/SMOKE DAMPER X FS DMP ON/OFF
ROOM 117 DAMPER X R117 DMP ON/OFF
ROOM 119 DAMPER X R119 DMP ON/OFF
DDC INPUT / OUTPUT SUMMARY TABLE - MZ-05 (EXISTING)
PROJECT NO: FTQW 16-2602
PROJECT:
HARDWARE SOFTWARE
EIELSON AFB Repair EMCS & Meters
LOCATION:
POINTS ALARMS
BUILDING 1168
DIGITAL ANALOG DIGITAL ANALOG EMCS FUNCTIONS
EXISTING POINT AVAILABILITY:
8 / 8 UI POINTS USED
2 / 4 AO POINTS USED
3 / 8 DO POINTS USED
O U
T P
U T
I N
P U
T
O U
T P
U T
I N
P U
T
E Q
U I P
M E
A
T U
S
M A
I N
T E
N A
N C
E
P R
E S
S U
R E
H I G
H
L
I M
I T
L O
W
L
I M
I T
M A
I N
T E
N A
N C
E
D A
Y N
I G
T
B A
C K
S C
H E
D U
L E
D
S
T A
R T
S
T O
P
T O
T A
L I Z
A T
I O
N
T R
E N
D
F I R
E
A
L A
T E
G R
A T
I O
N
D R
Y B
U L
B
E
C O
N O
M I Z
E R
F I R
E
A
L A
E
R R
I D
E
Comments
POINT DESCRIPTION
AH-3 DISCHARGE AIR TEMP. X X X X AH-3 DAT
AH-3 PRE-FILTER X X AH-3 PFLT ON/OFF
AH-3 OUTSIDE AIR DAMPER SWITCH X X AH-3 DMSW ON/OFF
AH-3 FLOW STATUS X X X AH-3 FLO ON/OFF
AH3 FREEZE STATUS X X AH-3 FRZ ON/OFF
AH-3 SMOKE DETECTOR X X X AH-3 SMK ON/OFF
AH-3 FILTER PRESSURE DROP X X X AH-3 FLT IN WC
FIREALARM STATUS X X FIREALARM ON/OFF
HEATING COIL 5 VALVE POSITION X X HC 5 VALVE %
HEATING COIL 6 VALVE POSITION X X HC 6 VALVE %
AH-3 START/STOP X X AH-3 S/S ON/OFF
AH-3 EXHAUST AIR DAMPER X AH-3 EAD ON/OFF
EXHAUST AIR DAMPER X EX AIR DM ON/OFF
DDC INPUT / OUTPUT SUMMARY TABLE - MZ-06 (EXISTING)
PROJECT NO: FTQW 16-2602
PROJECT:
HARDWARE SOFTWARE
EIELSON AFB Repair EMCS & Meters
LOCATION:
POINTS ALARMS
BUILDING 1168
DIGITAL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .